You are on page 1of 1

Epiroc

Settings
COP MD20 Ver. A
Worksite: ___________________________________________________________________

Drill rig type: __________ Serial Number: AVO ____________ Manufacturing Number:_________

COP: __________ Serial No.: AVO ____________

NB! Basic settings should only be done after the hydraulic oil in the tank has stabilised to normal working
temperature. The pressure at operators panel is about 5-10 bar above rock drill pressure.

Max. Base settings Actual settings

Intake accumulator (percussion) charged to


collaring pressure minus 40 bar 100 bar 80 bar . . . . . . . . . . bar

Return accumulator charged to 2 bar 2 bar . . . . . . . . . . bar

Damper idle pressure (measured at rock drill) 25 bar . . . . . . . . . . bar


Damper idle pressure (measured at operators panel) 30 bar . . . . . . . . . . bar
(damper flow 8 l/min)

Percussion pressure measured (at rock drill) during:


Collaring 140 bar . . . . . . . . . . bar
Drilling 225 bar 220 bar . . . . . . . . . . bar

Damper pressure during:


Collaring Approx. 55 bar . . . . . . . . . . bar
Drilling Approx. 90-130 bar . . . . . . . . . . bar

Frequency during drilling (at percussion pressure 225 bar): 82 Hz . . . . . . . . . . Hz

Theoretical rotational speed of drill bit:


D = 48 mm Approx. 250 rpm . . . . . . . rpm
D = 51 mm Approx. 240 rpm . . . . . . . rpm
D = 102 mm Approx. 170 rpm . . . . . . . rpm

Other drilling rig settings:


- Water flushing pressure 20-25 bar . . . . . . . . . . bar
- RPCF-pressure 25 bar . . . . . . . . . . bar
- Anti jamming 15 bar . . . . . . . . . . bar
- Lubricating air pressure at rock drill 3 bar* . . . . . . . . . . bar
- Corresponding lubricating air pressure at operators panel 5 bar . . . . . . . . . . bar
- ECL-lubricant pulses/minute 15 pulses/min . . . . Pulses/min

* see rig manual

Settings carried out by

…………………………………… …………………..
Service engineer in charge Date

No. 9852 3836 01d