The document provides calculations to determine the reinforced concrete design parameters for a foundation, including:
- Minimum concrete cover of 35mm for durability based on the structural class and exposure class.
- Nominal concrete cover of 50mm based on minimum cover of 35mm, allowance for deviation of 10mm, and reinforcement diameter of 32mm.
- Minimum effective depth of 156mm based on ratio of d/a from loading tables, with adopted footing height of 500mm.
The document provides calculations to determine the reinforced concrete design parameters for a foundation, including:
- Minimum concrete cover of 35mm for durability based on the structural class and exposure class.
- Nominal concrete cover of 50mm based on minimum cover of 35mm, allowance for deviation of 10mm, and reinforcement diameter of 32mm.
- Minimum effective depth of 156mm based on ratio of d/a from loading tables, with adopted footing height of 500mm.
The document provides calculations to determine the reinforced concrete design parameters for a foundation, including:
- Minimum concrete cover of 35mm for durability based on the structural class and exposure class.
- Nominal concrete cover of 50mm based on minimum cover of 35mm, allowance for deviation of 10mm, and reinforcement diameter of 32mm.
- Minimum effective depth of 156mm based on ratio of d/a from loading tables, with adopted footing height of 500mm.
LOCATION Preliminary sizing of foundation and Nominal cover for reinforcement
REFERENCE CALCULATIONS OUTPUT
Material strength for use in design EN 1992-1-1 Table 4.3N Concrete characteristic strength; fck fck = 30 N/mm2 EN 1992-1-1 Cl:3.2.2(3)P Characteristic yield strength of reinforcement steel; fyk fyk = 500 N/mm2 EN 1992-1-1 Table A.1 Unit weight of reinforced concrete; γconc. γconc. = 25 KN/m3
Preliminary sizing of foundation and Nominal cover for reinforcement
EN 1992-1-1 Table 4.1 Exposure class exposure class = XC2 Expected working life of the structure life span = 100 Years EN 1992-1-1 Table 4.3N [ Structural class Structural Class = S6
Calculation of concrete cover for durability
For structural and exposure class XC2 ,the minimum
S6 cover for durability Cmin,dur; EN 1992-1-1 Table 4.4N class Cmin,dur; = 35 mm
Calculation of concrete cover for bond
Assume maximum diameter for reinforcement in foundation; φ φ = 32 mm EN 1992-1-1 Cl: 4.4.1.2(3) Table 4.2N Cmin,b = 1.0φ Cmin,b = 32 mm Calculation of minimum concrete cover EN 1992-1-1 Cl: = 4.4.1.2(2)P Cmin = max(Cmin,b;Cmin,dur + ΔCdur,ϒ - ΔCdur,st - ΔCdur,add;10mm) Cmin 35 mm EN 1992-1-1 Cl: 4.4.1.2(6) (7) (8) ΔCdur,ϒ = 0 ,ΔCdur,st = 0 , ΔCdur,add = 0 Calculation of nominal cover EN 1992-1-1 Cl: 4.4.1.3(1)P Allowance for deviation ΔCdev = 10 mm EN 1992-1-1 Cl: = 4.4.1.1(2)P Cnom = Cmin + ΔCdev Cnom 45 mm Adopt Cnom = 50 mm Calculation of effective depth of foundation
Determine unfactored ground pressure
At S.L.S
Total service load = 1893 KN
Base area of footing = 8.41 m2
Unfactored ground 225.1 KN/m2 pressure
Determine ratio d/a from Table 5.23 by interpolation
The ration d/a > 0.145
a' is footing projection =
from column face 1250 mm
d > 156 mm
Footing height hmin = d + > 206 mm
Cnom Adopt h should not be less than 300mm h = 500 mm