Professional Documents
Culture Documents
Contents
Page 3 of 18
ARCODE HARDWARE MANUAL Version : 1.01
Page 4 of 18
ARCODE HARDWARE MANUAL Version : 1.01
● using shielded cables for motor, brake resistor and encoder connections outside the
device.
After switching off the device do not touch any electronic board or components until the
power capacitors are discharged (Min.5 minutes).
Do not make any connection to inverter when the power is on. Do not check components
and the signs on the electronic boards while device is running.
Be sure that the mains connections are correct. L1, L2 and L3 are line input terminals and
must not be disordered U, V and W. Otherwise, device may be damaged.
Do not mount the brake resistor on controller cabinet. Brake resistor must be mounted
vertically outside the control cabinet.
To prevent overheat, damage and fire be sure that the environment has sufficient
ventilation.
Do not store and operate the device at environments with extreme heat, extreme cold,
extreme humidity, water, iron dust and dust.
It is necessary that the used motor has a winding isolation which is made for the operation
with VVVF inverter.
Page 5 of 18
ARCODE HARDWARE MANUAL Version : 1.01
1.3 Copyright
Copyright by Arkel Elektrik Elektronik Tic. Ltd. Sti.
It is not allowed to redistribute the manual in its entirety or parts of it. Violations will be prosecuted
and lead to indemnity.
2 OVERVIEW
Arcode mainly has 3 functions which are the most required components of elevator systems. Those
are control of the lift system, drive of the main motor and evacuation system for unexpected power
loss conditions.
Page 6 of 18
ARCODE HARDWARE MANUAL Version : 1.01
Page 7 of 18
ARCODE HARDWARE MANUAL Version : 1.01
Some basic information can be obtained from 7-segment display. The information can be speed
value, error number, floor number or main state of the Arcode unit.
Additionally leds are used to indicate current state of the safety circuit nodes as well main
movements. Also CPU live indication is present.
3 MECHANICAL INSTALLATION
Installation Indoors
Area
Ambient -10°C to +40°C (NEMA Type 1 enclosure)
Temperature -10°C to +50°C (IP00 enclosure)
Drive reliability improves in environments without wide temperature
Page 8 of 18
ARCODE HARDWARE MANUAL Version : 1.01
fluctuations.
When using the drive in an enclosure panel, install a cooling fan or air conditioner
in the area to ensure that the air temperature inside the enclosure does not
exceed the specified levels.
Do not allow ice to develop on the drive.
Humidity 95% RH or less and free of condensation
Storage -20 to +60°C
Temperature
Surrounding Install the drive in an area free from:
Area • oil mist and dust
• metal shavings, oil, water or other foreign materials
• radioactive materials
• combustible materials (e.g., wood)
• harmful gases and liquids
• excessive vibration
• chlorides
• direct sunlight
Altitude
Vibration
Orientation Install the drive vertically to maintain maximum cooling effects.
NOTICE: Avoid placing drive peripheral devices, transformers, or other electronics near the drive as
the noise created can lead to erroneous operation. If such devices must be used in close proximity to
the drive, take proper steps to shield the drive from noise.
NOTICE: Prevent foreign matter such as metal shavings and wire clippings from falling into the
drive during installation. Failure to comply could result in damage to the drive. Place a temporary
cover over the top of the drive during installation. Remove the temporary cover before startup, as
the cover will reduce ventilation and cause the drive to overheat.
Page 9 of 18
ARCODE HARDWARE MANUAL Version : 1.01
B size mechanics
Width x length x height (mm) 257,5x372,5x194.75
Weight 9.5Kg.
Page 10 of 18
ARCODE HARDWARE MANUAL Version : 1.01
C size mechanics
Width x length x height (mm) 257.5x472x29
Weight 11.5kg
Arcode complies and certificated with EN61000-XXX standards that regulate EMC for Europe.
However be aware that Arcode is sensitive device against too high electromagnetic environment and
also generates some electromagnetic fields in surrounding area. So high current cables and sensitive
signal cables like encoders cables should be installed in far distance as possible.
Page 11 of 18
ARCODE HARDWARE MANUAL Version : 1.01
Page 12 of 18
ARCODE HARDWARE MANUAL Version : 1.01
4 ELECTRICAL INSTALLATION
EMI/RFI Filter
Controller
Power consumption ?
Motor PTC ?
Page 13 of 18
ARCODE HARDWARE MANUAL Version : 1.01
EMC filter and line switches are already included in the Arcode device. External filter usage is not
necessary.
Page 14 of 18
ARCODE HARDWARE MANUAL Version : 1.01
Encoders are very sensitive devices for electromagnetic interferences. For this reason encoder cables
are shielded. While routing encoder cables pay attention to route with enough distance to high
current cables.
Before connecting an encoder to the Arcode, please check encoder manufacturer user manual for
right signal positions, names and colors.
Page 16 of 18
ARCODE HARDWARE MANUAL Version : 1.01
For door bridging function optional door bridging board should be installed. All signals are routed
internally to the door bridging board.
Half duplex serial port on the IO board is reserved for group communication feature while others are
reserved for future use. Parameters for those serial communication lines are application depended
and not defined to any default value.
Page 17 of 18
ARCODE HARDWARE MANUAL Version : 1.01
PR1 and PR4 relays both have 1 Common and 1 normally open switch contact while PR2 and PR3
share same common signal. Thise contacts are able to control 250V AC voltages and flow 10 amp
current.
Page 18 of 18