Professional Documents
Culture Documents
Chair NIC Bed: hospital,standard,w/mattress MQ, NIC Trolley: medical gases MQ, NIC Bin: waste clinical 5l NIC
NIC, MQ
NIC 5L
NIC
Chair:Office, ergonomic NIC NIC
Trolley, dressing
Trolley: dressing, standard MQ, NIC NIC, MQ
Bin: waste clinical 50l NIC
NIC
Stretcher: patient,w/side rails MQ, NIC
Stretcher, patient, resuscitation, w/side rails
NIC
Chair
Chair: lounge NIC NIC, MQ
Trolley, instruments
Trolley: instruments MQ, NIC NIC, MQ
Bin: waste clinical 50l, (front elevation) NIC
Lounge
NIC, MQ
Table, examination
Table: examination, OPD MQ, NIC
NIC
Desk: standard, adjustable height 1200W, 600D NIC NIC, MQ
Trolley, cleaning
Trolley: cleaning MQ, NIC NIC
Bin: waste clinical 240l, (front elevation) NIC
Desk, 1200W, 600D Bin, 240l
NIC
Incubator
Incubator: neonatal MQ, NIC
NIC, MQ
Cabinet, Bedside
Cabinet bedside drawer unit, lockable NIC NIC, MQ
Trolley, soiled
Trolley: soiled linen MQ, NIC
linen
NIC
Resuscitaire: neonatal MQ, NIC
Resuscitaire
NIC, MQ
Fridge
NIC, MQ
Trolley, medicine
Trolley: medicine MQ, NIC
Whiteboard: magnetic 900x900 NIC
Locker: full height NIC NIC, MQ
Trolley: rescusitation MQ, NIC
Lock
Trolley Resc.
Shelving, floor st
Shelving: floor standing, 1000W, 450D NIC NIC
Trolley, anaestheti
c
Trolley: anaesthesia MQ, NIC
Shelving: stainless steel wire mesh, mobile NIC Trolley: mayo, adjustable MQ, NIC
NIC
Engineering services: Electrical (ref to MEP eng. package) Engineering services: Plumbing (ref to MEP eng. package) Engineering services: Ventilation(ref to MEP eng. package) Naming
WBF+0_01_S
DB
Distribution board MEP eng. DBW ⌀110
Plumbing: drainage pipe, black water MEP eng. DV Disc Valve, ceiling mount MEP eng. Exterior windows:
Window, [W]
UPS, bracket support, wall mount MEP eng. DGW ⌀50 Plumbing: drainage pipe, grey water MEP eng. Inline Fan, mount at ceiling void MEP eng.
DRW ⌀100
House, [B]
Plumbing: drainage pipe, rainwater MEP eng. Exhaust Louvre (section view) MEP eng. Elevation (facing), [F](ront)
Fan: ceiling (plan view) MEP eng. Drain: waste water, outlet MEP eng. Air Conditioning Indoor Unit, wall mount MEP eng. Floor, [G+0]
Window number, [01-...]
Undercut supply MEP eng. Window type [S](liding)
WBR+0_01_F
Fan: ceiling (section view) MEP eng. Exterior windows:
Window, [W]
House, [B]
Fan: regulator MEP eng. Elevation (facing), [R](ight)
GPO, double gang socket, wall mounted MEP eng. Floor, [G+0]
Window number, [01-...]
Switch: 1 gang, light / fan MEP eng. Window type [F](ixed)
Switch: 2-gang, light, fan MEP eng.
DBB+0_01_P
Switch: 3-gang, light, fans MEP eng. Exterior doors:
Door, [D]
Luminaires House, [B]
Referencing Elevation (facing), [B](ack)
Light: circular, surface mount MEP eng. Wheelchair: turning circle diam. 150 cm Floor, [G+0]
Door number, [01-...]
Light: circular, surface mount (section view) MEP eng. Door type [P](air)
Light: linear. surface mount MEP eng. Symbol: set-out, floor and wall tiles,
DBL+0_01_Si
Light: linear. surface mount (section view) MEP eng. Exterior doors:
Door, [D]
House, [B]
Elevation (facing), [L](eft)
Floor, [G+0]
Door number, [01-...]
Door type [S](ingle)
069 BaDH
Architectural Pioneering Consultants GmbH Support to Strengthening Health
Hardstrasse 69 Systems in Puntland:
8004 Zurich, Switzerland Bacaadweyn District Hospital
+41 44 586 1716
info@apc-tz.com
Legend
TENDER
Resp: im
Detailed Design
Date: Signature:
Notes:
Data regarding existing structures is based on information provided by UNICEF and their appointed Consultants.
All measurements to be verified on site. All levels to be verified on site.
Drawing to be read in conjunction with architectural specifications, structural engineering and MEP engineering
drawings and documentation.
Any discrepancies to be referred to the architects for clarification.
Do not scale from this drawing.
GSPublisherVersion 0.0.100.14 Print drawing in color