COLUMN SCHEDULE

A B C C21 : Fy275 , COVER = 40MM C21 : Fy275 , COVER = 40MM C21 : Fy275 , COVER = 40MM C21 : Fy275 , COVER = 40MM C21 : Fy275 , COVER = 40MM C21 : Fy275 , COVER = 40MM
CONFINING ZONE = 450 MM CONFINING ZONE = 500 MM CONFINING ZONE = 450 MM CONFINING ZONE = 450 MM CONFINING ZONE = 450 MM CONFINING ZONE = 450 MM
4030 2850
SECOND FLOOR
TO
4 ROOF BEAM
Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS
C1 C2 C3 Ø10 @ 75 Ø10 @ 75 Ø10 @ 200 Ø10 @ 75 Ø10 @ 75 Ø10 @ 250 Ø10 @ 75 Ø10 @ 75 Ø10 @ 200 Ø10 @ 75 Ø10 @ 75 Ø10 @ 200 Ø10 @ 75 Ø10 @ 75 Ø10 @ 200 Ø10 @ 75 Ø10 @ 75 Ø10 @ 200
2850

500
400

400

400

400

400
Ø16 Ø16 Ø16 Ø16 Ø16 Ø16
400 500 400 400 400 400
3
C4 C5 C6
8-Ø16
C21 : Fy275 , COVER = 40MM
16-Ø16
C21 : Fy275 , COVER = 40MM
8-Ø16
C21 : Fy275 , COVER = 40MM
8-Ø16
C21 : Fy275 , COVER = 40MM
8-Ø16
C21 : Fy275 , COVER = 40MM
8-Ø16
C21 : Fy275 , COVER = 40MM
CONFINING ZONE = 570 MM CONFINING ZONE = 570 MM CONFINING ZONE = 570 MM CONFINING ZONE = 570 MM CONFINING ZONE = 570 MM CONFINING ZONE = 570 MM
3000

TIE BEAM
2
C7 C8 C9
Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS
TO
Ø10 @ 75 Ø10 @ 75 Ø10 @ 200 Ø10 @ 75 Ø10 @ 75 Ø10 @ 250 Ø10 @ 75 Ø10 @ 75 Ø10 @ 200 Ø10 @ 75 Ø10 @ 75 Ø10 @ 200 Ø10 @ 75 Ø10 @ 75 Ø10 @ 200 Ø10 @ 75 Ø10 @ 75 Ø10 @ 200
SECOND FLOOR
2614

500
400

400

400

400

400
1 400
Ø16
500
Ø16
400
Ø16
400
Ø16
400
Ø16
400
Ø16
C10 C11 C12 8-Ø16 16-Ø16 8-Ø16 8-Ø16 8-Ø16 8-Ø16
C21 : Fy275 , COVER = 40MM C21 : Fy275 , COVER = 40MM C21 : Fy275 , COVER = 40MM C21 : Fy275 , COVER = 40MM C21 : Fy275 , COVER = 40MM C21 : Fy275 , COVER = 40MM
CONFINING ZONE = 450 MM CONFINING ZONE = FULL HEIGHT CONFINING ZONE = 450 MM CONFINING ZONE = 450 MM CONFINING ZONE = 450 MM CONFINING ZONE = 450 MM
FOOTING
TO Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS
Ø10 @ 75 Ø10 @ 75 Ø10 @ 150 Ø10 @ 75 Ø10 @ 75 --- Ø10 @ 75 Ø10 @ 75 Ø10 @ 150 Ø10 @ 75 Ø10 @ 75 Ø10 @ 150 Ø10 @ 75 Ø10 @ 75 Ø10 @ 125 Ø10 @ 75 Ø10 @ 75 Ø10 @ 150
TIE BEAM

500
400

400

400

400

400
Ø16 Ø16 Ø16 Ø16 Ø16 Ø16
400 500 400 400 400 400
8-Ø16 16-Ø16 8-Ø16 8-Ø16 8-Ø16 8-Ø16
COLUMN MARKED C7 C8 C9 C10 C11 C12
CIVIL ENGINEER: PROJECT TITLE / LOCATION: OWNER: CADD OPTR.: SHEET CONTENTS: REMARKS/REVISED: SHEET NO:
PTR NO.: 9894430 REG NO.:0122517
COLUMN PLAN
ST
DATE.:
TWO STOREY RESIDENTIAL
BUILDING CHECKED:
NHEL ADRIAN B. BARTOLINE ISSUED ON.: JANUARY 28, 2021 TIN NO.:441-590-802-000 MR. RONALDO F. ABETO
CIVIL ENGINEER DATE:
MRS. MYLENE M. ABETO
ISSUED AT:MANILA LOT 75, BLK. 1, 1483 MONGGO ST., NAPICO
MANGGAHAN, PASIG CITY
APPROVED:
DATE:
0 4B