1 Loading
Staircase Case 1: (Horizontal UDL) 0.74 kN/m
Case 2: UDL applied to the infill of kN/2 1.00 kN/m2
Case 3: Point Load applied to part of the infill kN 0.50 kN
h= 1180 mm
3 Load Calculation
Case 1
P= x*UDL*tributary width = 1.3098 kN
M= PL/4 = 0.386391 kN-m
Case2
W= x*UDL*tributary width*D = 0.07500 kN
2
M= WL /8 = 0.01305 kN-m
Case3
P= = 0.50000 kN
M= PL/4 = 0.1475 kN-m
Therefore,max
P= 1.30980 kN
M= 0.38639 kN ,maximum Moment at the support
Job No: -
Sheet No:
Designed by: SMA Checked by: KH TANN Date: -
Title:
Pontoon Handrail at Kranji Pumping Stations
4 Capactiy check
Mc= PyS PySx = 466,652 N-mm = 0.467 kN-m therefore:Okay BS 5950 4.2.5.2
4.3 Deflection
W= 0.74000 kN/m = 0.74000 N/mm
L= 1.18000 m = 1180.0 mm
E= 180000 N/mm2
I= 105507.2 mm3 c= 25.0 mm
= 0.1967 mm