UNITS WITH SPLIT LEVELS AND WITHOUT INTERVENING DOOR BETWEEN THE ADJACENT
LEVELS, A SMOKE ALARM INSTALLED ON THE UPPER LEVEL SHALL SUFFICE FOR THE
8"
8"
8"
ADJACENT LOWER LEVEL PROVIDED THAT THE LOWER LEVEL IS LESS THAN ONE FULL
STORY BELOW THE UPPER LEVEL.
8"
3 - 4/0 ALU.THHN
5'-4"
5'-4"
6'
8"
#14 AND #12 COPPER TO
3'-1" 3' 0'-4" 3' 3' 0'-7" 3' 3'-2" 3' 3' 3'-1" LIGHTS AND OUTLETS
СGFI
0'-4"
200 AMP ALL SMOKE ALARMS SHALL BE LISTED AND INSTALLED IN ACCORDANCE WITH THE
2'-3"
2'-3"
11'-4" 20'
PROVISIONS OF THIS CODE AND THE HOUSEHOLD FIRE WARNING EQUIPMENT PROVISIONS
2'-3"
2'-3"
GFI СGFI MAIN DISC. #10 COPPER TO
WATER HEATER OF NFPA 72.
#8 COPPER TO RANGE
*EGRESS
4'-7"
UNDERGROUND
*EGRESS
SERVICE BY WHEN ONE OR MORE SLEEPING ROOMS ARE ADDED OR CREATED IN EXISTING DWELLINGS,
3'
3'
3'
3'
POWER COMPANY THE INDIVIDUAL DWELLING UNIT SHALL BE PROVIDED WITH SMOKE ALARMS LOCATED AS
8'-4"
REQUIRED FOR NEW DWELLINGS: THE SMOKE ALARMS SHALL BE INTERCONNECTED AND
#4 COPPER TO 5 /8" GROUND ROD
DININIG ROOM ALSO SERVICE TO BE BONDED
HARD WIRED.
4"
4"
0'-4"
0'-4"
TO FOOTING STEEL
9'-6" CEILING
*EGRESS
EXCEPTIONS:
*EGRESS
GFI
3'
3'
3'
3'
1. SMOKE ALARMS IN EXISTING AREAS SHALL NOT BE REQUIRED TO BE INTERCONNECTED
3'-5"
UP
GROUND GROUND ROD AND HARD WIRED WHERE THE ALTERATIONS OR REPAIRS DO NOT RESULT IN THE
ROD 6' APART REMOVAL OF INTERIOR WALL FINISHES EXPOSING THE STRUCTURE, UNLESS THERE IS
6'-4"
5'-5"
5'-5"
23'-10"
6'-2"
4
2. REPAIRS TO THE EXTERIOR SURFACES OF DWELLINGS ARE EXEMPT FROM THE
23'-10"
5 REQUIREMENTS OF THIS SECTION.
FIN. FLR.
TV 6
ELEC. RISER IN NEW CONSTRUCTION, THE REQUIRED SMOKE ALARMS SHALL RECEIVE THEIR
2'-3" x 5'-2"
7
PRIMARY POWER FROM THE BUILDING WIRING WHEN SUCH WIRING IS SERVED FROM
0'-0" A.F.F. A COMMERCIAL SOUCE, AND WHEN PRIMARY POWER IS INTERRUPPTED, SHALL
43'
43'
2'-3"
8 NOTE:
3'-0" x 5'-2" 3'-0" x 5'-2"
*TEMP
2'-3"
30'-4"
9
ELECTRICAL MATERIALS AND INSTALLATIONS SHALL
COMPLY W/APPLICABLE PROVISIONS OF THE NATIONAL ELEC.CODE, A DISCONNECTING SWITCH OTHER THAN THOSE REQUIRED FOR OVERCURRENT
15'-6"
3'
СGFI
WHEN INSTALLED IN BUILDINGS WITHOUT COMMERCIAL POWER OR IN BUILDINGS
LIVING ROOM 11 THAT UNDERGO ALTERATIONS, REPAIRS OR ADDITIONS REGULATED BY SECTION
37'
37'
9'-6" CEILING R313.1.1.
4"
12 KITCHEN
0'-4"
*EGRESS
GFI
13 9'-6" CEILING
W.M.
3'
3'
7'-8"
CARBON MONOXIDE
14
15
3'
17
СGFI СGFI
4'
4'
18 16'-7"
FL. STATUTE 553.885 CARBON MONOXIDE ALARM REQUIRED IN EVERY BUILDING FOR
6'-2"
2'-2" 4"
WHICH A BUILDING PERMIT IS ISSUED FOR NEW CONSTRUCTION. HAVING A
0'-5"
СGFI
16'-7"
FOSSIL-FUEL-BURNING HEATER OR APPLIANCE, A FIREPLACE, OR A ATTACHED GARAGE
2'-2"
3'-0" x 5'-2"
СGFI
3'-2"
3'
0'-1"
6'-6"
*EGRESS
0'-1"
5' BEDROOM 1
3'
3'
A/C
ELECTRICAL NOTES:
2'-3"
GFI
2'-3"
0'-4"11'-6"
4"
2'-8" ALL WORK SHALL BE DONE IN STRICT ACCORDANCE WITH APPLICABLE CODES AND
8'-8"
3'
8'-4"
8'-4"
5'
5'-4"
0'-0" A.F.F. FIXTURE, OUTLET, AND SWITCH LOCATIONS ARE DIAGRAMMATIC. CONTRACTOR
3'-8"
3'
RECEPTACLE LOCATIONS
8"
ELECTRICAL PLAN
ELECTRICAL DEVICES: ABOVE FINISHED FLOOR:
ELECTRICAL KEY
5' 2'-8" SWITCHES OVER COUNTER . . . . . . . . . . 48" TO CL
Project No.
SD SMOKE DETECTOR FRONT DOOR COACH LIGHT . . . . . . . . . 72" TO CL