WIND PRESSURE FOR ROOF WIND PRESSURE FOR STRUCTURAL

COMPONENTS AND WALL COMPONENTS


PANEL EDGE
CLADDING (P.S.F.) AND CLADDING (P.S.F.) SPECIFICATIONS:
150 MPH ULTIMATE WIND LOAD 150 MPH ULTIMATE WIND LOAD
WARNING:
THE STRUCTURAL INTEGRITY OF THE BUILDING SHOWN ON
SIMPSON PSCL 5/8 (TYP.) ROOF ANGLE 20-27 DEGREES WALL AREA THESE PLANS IS DEPENDANT UPON THE COMPLETION ACCORDING TO
OPENING AREA OPENING AREA PLANS AND SPECIFICATIONS. STRUCTURAL MEMBERS ARE NOT SELF-
1 2 3 4 5 SUPPORTING DURING CONSTRUCTION AND REQUIRE TEMPORARY BRACING
PSCL
5/8
PSCL
5/8
PSCL
5/8
PSCL
5/8

UNTIL PERMANANTLY AFFIXED TO THE STRUCTURE AS DIRECTED. THE


PRESSURE +18.1 PSF +18.1 PSF +18.1 PSF PRESSURE +24.3 PSF +24.3 PSF DESIGNER ASSUMES NO RESPONSIBILITY FOR THE STRUCTURE
10 FT. SQ. 10 FT. SQ. DURING CONSTRUCTION, UNLESS THE CONSTRUCTION IS
SUCTION -32.5 PSF -44.9 PSF -44.9 PSF SUCTION -26.3 PSF -32.5 PSF SUPERVISED BY THE STRUCTURAL ENGINEER DURING CONSTRUCTION.
5/8" CDX SHEATHING

20 FT. SQ.
PRESSURE +15.6 PSF +15.6 PSF +15.6 PSF
20 FT. SQ.
PRESSURE +23.2 PSF +23.2 PSF CAST IN PLACE CONCRETE:
8D RING SHANK NAILS @ SUCTION -28.8 PSF -40.1 PSF -40.1 PSF SUCTION -25.2 PSF -30.3 PSF 1. ALL REINFORCED CONCRETE SHALL BE NORMAL WEIGHT.
6" O.C. @ ALL PANEL THE MINIMUM 28 DAY COMPRESSIVE STRENGTH SHALL BE AS FOLLOWS;
EDGES TYP. SHEATHING SHALL BE STAGGERED PRESSURE +12.3 PSF +12.3 PSF +12.3 PSF PRESSURE +21.8 PSF +21.8 PSF A.) SLAB ON GRADE = 2500 PSI MIN.
50 FT. SQ. 50 FT. SQ. B.) FOOTINGS, COLUMNS, TIE BEAMS = 3000 PSI
SUCTION -23.9 PSF -33.8 PSF -33.8 PSF SUCTION -23.8 PSF -27.5 PSF C.) PRECAST "U" BLOCK = 4000 PSI
D.) FILLED CELLS = 3000 PSI
8D RING-SHANK NAILS @ 6" O.C. PRESSURE +10.0 PSF +10.0 PSF +10.0 PSF PRESSURE +20.6 PSF +20.6 PSF
@ ALL INTERMEDIATE 100 FT. SQ. 100 FT. SQ. 2. CONCRETE REINFORCING STEEL SHALL BE GRADE 60
SUPPORT MEMBERS SUCTION -20.2 PSF -29.0 PSF -29.0 PSF SUCTION -22.7 PSF -25.2 PSF
3. WELDED WIRE FABRIC SHALL BE 6" X 6" - W1.4/W1.4
TYP.

A
2x10 RAFTERS @ 16" O.C.

A
3 2 3
FOUNDATION REINFORCING:
NOTE: AT OVERHANGS AND 5 45 5 4 5 1. THE REQUIRED MINIMUM LAP SPLICE FOR REBARS SHALL BE (40 BAR DIAMETERS).
WITHIN 4' OF ALL EAVES 1
END CONDITION 2 2
AND RIDGES NAILING SHALL 2. EMBED FOOTING DOWELLS 6" MINIMUM INTO FOOTINGS, EXTEND INTO
BE 4" AT PANEL EDGES TIE BEAMS AND BEND HOOKS OVER TOP BAR 25" MINIMUM.
AND 6" AT INTERMEDIATE END ZONE DISTANCE:

ROOF SHEATHING 3 2 3 10% OF LEAST HORIZONTAL DIMENSION OR 40% OF EAVE

AA
SUPPORTS.
HEIGHT, WHICHEVER IS LESS BUT NOT LESS THAN EITHER 4%
3 2 3
OF THE LEAST HORIZONTAL DIMENSION OR 4 FEET. CARPENTRY:
NAILING DETAIL 2 1
2
ZONE 2 = 4'-0"
1. DIMENSIONED LUMBER SHALL BE DRESSED S4S, AND SHALL BEAR THE
GRADE STAMP OF THE MANUFACTURER'S ASSOCIATION.
2. ALL LUMBER SHALL BE SOUND, SEASONED, AND FREE FROM WARP.
ZONE 3 = 4'-0"
3. ALL LUMBER SHALL BE SOUTHERN PINE NO. 2 GRADE OR BETTER WITH
3 3 ZONE 5 = 4'-0" 19% MAXIMUM MOISTURE CONTENT.
2 4. ALL LUMBER IN CONTACT WITH MASONRY OR CONCRETE SHALL BE

PRESSURE TREATED.
5. PRESSURE TREATED LUMBER SHALL BE IMPREGNATED WITH A CCA SALT
TREATMENT IN ACCORDANCE WITH F.S. TT-W-571 AND BEAR THE
AMERICAN WOOD PRESERVERS INSTITUTE QUALITY MARK LP-2.
6. PLYWOOD SHEATHING SHALL BE CDX WITH EXTERIOR GLUE. ALL
ROOF SHEATHING TO BE INSTALLED WITH PLYCLIPS.
TABLE R301.7 OF THE FLORIDA BUILDING CODE SEVENTH EDITION (2020)
7. INSTALL BRIDGING IN ALL FLOOR OR ROOF JOISTS AT 8'-0" O.C.
1/2" CDX SHEATHING ALLOWABLE DEFLECTION OF STRUCTURAL MEMBERS MAXIMUM. INSTALL BLOCKING IN ALL WALL STUDS @ MID-HIEGHT.
8. ALL NAILING AND BOLTING SHALL COMPLY WITH AMERICAN INSTITUTE
STRUCTURAL MEMBER ALLOWABLE OF TIMBER CONSTRUCTION REQUIREMENTS.
DEFLECTION
6D NAILS @ 4" O.C. RAFTERS HAVING SLOPES GREATER THAN 3/12 WITH NO FINISHED CEILING ATTACHED TO 9. ALL CONNECTION HARDWARE SHALL BE GALVANIZED AND SUPPLIED BY
@ ALL PANEL EDGES RAFTERS L/180 SIMPSON STRONGTIE CO.
TYP. PANEL EDGE
10. PROVIDE A SINGLE PLATE AT THE BOTTOM AND DOUBLE PLATE AT THE
INTERIOR WALLS AND PARTITIONS H/180 TOP OF ALL LOAD BEARING STUD WALLS. SILL PLATES SHALL BE BOLTED TO
FOUNDATION AT A MAXIMUM OF 4'-0" O.C.
6D NAILS @ 6" O.C. FLOORS AND PLASTERED CEILINGS 11. STUDS SHALL BE DOUBLED AT ALL ANGLES AND AROUND ALL OPENINGS.
@ ALL INTERMEDIATE L/360
SUPPORT MEMBERS STUDS SHALL BE TRIPLED AT ALL CORNERS.
TYP. ALL OTHER STRUCTURAL MEMBERS 12. ALL OUTSIDE CORNERS SHALL BE BRACED WITH A DIAGONAL 1 X 4 LET
L/240 INTO OUTSIDE EDGE OF 2 X 4 STUDS, UNLESS PLYWOOD SHEATHING IS
SHOWN ON DRAWINGS.
EXTERIOR WALLS WITH PLASTER OR STUCCO FINISH H/360
2X4 STUDS @ 16" O.C.

EXTERIOR WALLS--WIND LOADS WITH BRITTLE FINISHES H/240

EXTERIOR WALLS--WIND LOADS WITH FLEXIBLE FINISHES L/120

LINTELS SUPPOERTING MASONRY VEENEER WALLS L/600

END CONDITION

WALL SHEATHING

STRUCTURAL
NAILING DETAIL

NOTES
Project No.
PETE ALFONSO JR.
ARCHITECT
LIC. No. 8735
PHONE No.: 813 231-5800
EMAIL: Alfonso169@aol.com

ARCHITECT CERTIFIES, TO THE BEST OF HIS KNOWLEDGE, THAT ALL


PLANS AND SPECIFICATIONS COMPLY WITH THE MINIMUM BUILDING
CODES.
S0.1