BAFFLE (TYPICAL)
a3.1
1
ELEV. 17'-4" RESIDENTIAL SIXTH EDITION (2017), SECTION R318.1)
ELEVATION IN
OR
26'-3" FLOOD ZONE 2. PERMANENT SIGNAGE FOR TREATMENT SHALL BE POSTED NEAR WATER HEATER
LOCATIONS R-38 INSULATION ELECTRICAL PANEL. (PER FBC RESIDENTIAL SIXTH EDITION (2017), SECTION R318.1)
GRADE
2x8 P.T. WOOD FASCIA 1/2" CEILING BOARD 3. A 6" MINIMUM CLEARANCE SHALL BE PROVIDED BETWEEN EXTERIOR WALLS AND
WINDOW 1'-0" 3'-0" FOR TERMITE INSPECTION (4" MINIMUM FOR GARAGE/PATIO SLABS). (PER FBC RESIDENTIAL
3'-0"
SIXTH EDITION (2017), SECTION R318.1)
DOUBLE 2X4 TOP PLATE
4'-5"
SIDEWALLS
VENTED VINYL SOFFIT 4. A 1'-0" MINIMUM CLEARANCE SHALL BE PROVIDED BETWEEN THE STRUCTURE'S
AND CONDENSATE LINES, ROOF DOWNSPOUTS, SPRINKLER SYSTEMS AND RISERS FOR SPRAY
3'-0"
W.H. SIMPSON SP2 AT EACH STUD OR
WALL
CL OF
MESH USE 6 MIL VAPOR BARRIER HEADS. (PER FBC RESIDENTIAL SIXTH EDITION (2017), R318.1.6)
EQUAL FROM STUD TO TOP
OF 6X6 1.4X1.4 W.W.M. OR FIBER 5'-2" PLATE. 5. APPROVED TERMITE PROTECTION SHOULD BE PLACED/PROTECTED W/ 6MIL VAPOR
ANY SOIL
(ALLOWABLE UPLIFT = 890) BARRIER. IT SHALL BE DONE AFTER EXCAVATION, BACKFILLING AND COMPACTION.
FILL REINFORCED W/ 1 LAYER DISTURBANCE AFTER TREATMENT SHALL BE PROTECTED BY PERMANENT PLASTIC OR METAL
COMPACTED TERMITE TREATED
3'-7"
FORMS IN CONCRETE FLOORS BOXED OUT OR CONSTRUCTED FOR THE INSTALLATION OF
BE
3 1/2" CONC. SLAB OVER @ WELL PLUMBING LINES AND THE LIKE. IF SOIL IF DISTURBED AFTER TREATMENT, SOIL SHOULD
RETREATED. (PER FBC RESIDENTIAL SIXTH EDITION (2017), SECTIONS R318.1.1, R318.1.2, R318.1.3,
WALL
CL OF
SLIDING DOOR
2 LAYERS VAPOR
0'-0" A.F.F.
FIN. FLR.
24'-0"
PROVIDE 1/2" EXPANSION REFER TO FOUNDATION NOTE EDITION (2017), SECTION R318.1.6)
DOOR
MATERIAL BETWEEN NO.4 BELOW FOR SLAB SLEEVES
HOUSE/PORCH SLAB 8. NON-CELLULOSE MATERIAL W/ TERMITICIDE SHALL BE USED FOR PROTECTIVE
AROUND METAL PIPINGS PENETRATING ON SLAB-ON- GRADE FLOORS. (PER FBC RESIDENTIAL
SIXTH EDITION (2017), SECTION R318.2)
9. POST CONSTRUCTION, ALL LOOSE WOOD AND DEBRIS SHALL BE COMPLETELY REMOVED
FROM UNDER THE BUILDING WITHIN 1'-0" EXCEPT FOR NATURALLY DURABLE OR P.T. WOOD
FOR GROUND CONTACT AND INSTALLED 6" MIN. FROM THE STRUCTURE FOR TERMITE
2 X 4 WOOD STUDS AT 16" O.C. INSPECTION. (PER FBC RESIDENTIAL SIXTH EDITION (2017), SECTION R318.3)
WINDOW
MAX.
35'-0"
FIN. FLR.
SLOPE DOWN
a3.1
TRUSS. REFER TO STRUCTURAL
2
R-13 BATT INSULATION
REFER TO FOUNDATION NOTE DRAWINGS
NO.4 BELOW FOR SLAB
0'-0" A.F.F.
FIN. FLR.
REFER TO FOUNDATION NOTE 2 X 4 RIBBON BOARD
NO.6 BELOW FOR WALLS
FOUNDATION PLAN
SIDING ON 8" C.M.U.
GARAGE
25" MIN. OVERLAP
#5 DOWEL
FOUNDATION PLAN
3 1/2" CONC. SLAB WITH FIBER MESH
TOP OF SLAB TO BE 12" MIN. OVER 6 MIL. VAPOR BARRIER
SCALE: 3/8" = 1'-0"
Project No.
ABOVE GRADE
GARAGE FF SLAB
ELEV. (-)0'-8" B.F.F.
24"