Model UT602/603: OPERATING MANUAL P/N:110401103689X DATE:2018.06.26 REV.

2 Model UT602/603: OPERATING MANUAL

Rules For Safe Operation Button Description C. Capacitance Measurement (UT603 only, see figure 5) Remarks: Remarks: A. General Service
 When carrying out measurement at 2mH, short circuit  Overload protection: 250V DC or AC rms at all ranges.  Periodically wipe the case with a damp cloth and mild
Warning Power Press the Power down to turn the Meter on.
the test clip first, then carrying out the measurement.  At 20M range, short circuit test lead, LCD displaying detergent. Do not use abrasives or solvents.
Press the Power again to turn the Meter power off. Warning
To avoid possible electric shock or personal injury, The actual correct reading is the measured reading 12 digits is normal. During measurement minus these  To clean the terminals with cotton bar with detergent, as
and to avoid possible damage to the Meter or to the Hold Press HOLD once to enter the hold feature, the LCD To avoid damage to the Meter or to the equipment minus the short circuit reading. 12 digits from the obtained reading. dirt or moisture in the terminals can affect readings.
equipment under test, adhere to the following rules: (UT602 display . under test, disconnect circuit power and discharge all  When testing a small value inductance, it is better to use  When measuring 20 and 200 range, short circuit test  Turn the Meter power off when it is not in use and take
high-voltage capacitors before measuring capacitance. the small value jack. clips to display the resistance value of the test lead. out the battery when not using for a long time.
 Before using the Meter inspect the case. Do not use only) Press HOLD again to exit hold feature, the Use the DC Voltage function to confirm that the  The Meter cannot check the quality of the inductance. Subtract this value from the measurement value to obtain  Do not store the Meter in a place of humidity, high
the Meter if it is damaged or the case (or part of the disappear. (figure 3) capacitor is discharged.  When inductance measurement has been completed, the correct tested value. temperature and strong magnetic field.
case) is removed. Look for cracks or missing plastic.
Pay attention to the insulation around the connectors. L-C Press L-C down to enter the Capacitance The Meter's capacitance ranges are: 2nF, 20nF, 200nF, disconnect the connection between the testing clips and B. Replacing the Battery (see figure 8)
B. Continuity & Diodes
(UT603 measurement mode. 2µF, 20µF, 200µF and 600µF. the circuit under test and remove the testing clips away
 Inspect the test clips for damaged insulation or Overload
from the input terminals of the Meter. Function Range Resolution
exposed metal. Check the test clips for continuity. only) Press L-C up to enter the Inductance measurement To measure capacitance, connect the Meter as follows:
Protection
Replace damaged test clips with identical model mode.
number or electrical specifications before using the 1. Set the rotary switch to F measurement mode. If the Diode 1mV
value of capacitor to be measured is unknown, use the 250V rms
Meter. Continuity 1
maximum measurement position 600µF and decrease
 Do not apply voltage to the Meter.
the range step by step until a satisfactory reading is Remarks:
 The rotary switch should be placed in the right obtained and the overloading icon "1" is disappeared.
(figure 4)  Diode:
position and no any changeover of range shall be
2. Insert the red test clip into the CAP + terminal and black Open Circuit Voltage around 5.8V, forward current around
made during measurement is conducted to prevent (figure 8)
test clip into the CAP - terminal. For small value 1mA.
damage of the Meter.
capacitor measurement, insert the capacitor into the (figure 7)  Continuity
 Do not apply more than 30Vrms between the small value jack. Warning
(figure 2) 10 , beeper comes on continuously.
terminals and the grounding to avoid electric shock (figure 1)
Warning 3. Use the red test clip to clip the capacitor's positive and > 10 , beeper may or may not comes on. To avoid false readings, which could lead to possible
and damage to the Meter.
the black test clip to clip the capacitor's negative when E. Transistor hFE Measurement (see figure 7) electric shock or personal injury, replace the battery
 Use the proper terminals, function, and range for To avoid damages to the Meter or to the devices under the capacitor has polarity. To measure transistor, set up the Meter as follows: C. Capacitance Test (UT603 only) as soon as the battery indicator " " appears.
your measurements. Display Symbols (see figure 2) test, disconnect circuit power and discharge all the 4. The measured value shows on the display. 1. Set the rotary switch to hFE measurement mode. To replace the battery:
 Do not use or store the Meter in an environment of high-voltage capacitors before measuring diodes and Range Resolution Accuracy Testing Frequ-
2. Check that the transistor is PNP or NPN type. 1. Turn the Meter power off and remove all connections
high temperature, humidity, explosive, inflammable No. Symbol Meaning continuity. ency / Voltage
3. Insert the Insert the transistor to be measured to the from the terminals.
and strong magnetic field. The performance of the Do not input more than DC 60V or AC 30V voltages
1 The battery is low. corresponding Transistor Jack 2.000nF 0.001nF 2. Remove the screw from the battery compartment, and
Meter may deteriorate after dampened. to avoid electric shock and damage to the Meter.
4. The Meter displays the tested transistor's nearest value 20.00nF 0.01nF (1%+5) 1kHz/150mV separate the battery compartment from the case bottom.
Warning: To avoid false readings,
 Disconnect circuit power and discharge all high- Testing Diodes 3. Remove the battery from the battery compartment.
which could lead to possible electric shock Note: 200.0nF 0.1nF
voltage capacitors before testing resistance, 4. Replace the battery with a new 9V alkaline battery
or personal injury, replace the battery as Use the diode test to check diodes, transistors, and other  When transistor measurement has been completed, 2.000µF 0.001µF (NEDA1604 or 0062 or 6F22 or 006P)
continuity, capacitance or diodes.
semiconductor devices. The diode test sends a current disconnect the connection between the testing clips and 5. Rejoin the case bottom and battery compartment, and
 Replace the battery as soon as the battery indicator soon as the battery indicator appears. through the semiconductor junction, and then measures 20.00µF 0.01µF (4%+5) 100Hz/15mV
the circuit under test and remove the testing clips away reinstall the screw.
appears. With a low battery, the Meter might 2 β Transistor Test the voltage drop across the junction. A good silicon junction 200.0µF 0.1µF
from the input terminals of the Meter.
produce false readings that can lead to electric shock drops between 500mV and 800mV. C. Replacing the Fuse (see figure 9)
3 Test of diode. 600µF 0.001mF Reference only 100Hz/1.5mV
Overview and personal injury. To test a diode out of a circuit, connect the Meter as follows: General Specifications
4 The continuity buzzer is on. Remarks:
This Operating Manual covers information on safety and  Remove test clips from the Meter and turn the Meter  Fused Protection for Inductance Input Terminal (UT602):
power off before opening the Meter case. 1. Insert the red test clip into the terminal and  Overload Protection
cautions. Please read the relevant information carefully Measurement Operation (figure 5) 0.315A, 250V, fast type fuse, 5x20 mm.
the black test clip into the COM terminal. 0.315A, 250V, fast type fuse, 5x20 mm
and observe all the Warnings and Notes strictly.  When servicing the Meter, use only the same model Note Fuse Protection for Inductance and capacitance Input
number or identical electrical specifications  Make sure the Low Battery Display is not on, 2. Set the rotary switch to .  Measure of Capacitance:
Terminal (UT603):
Warning replacement parts. otherwise false readings may be provided.  To minimize the effect of capacitance stored in the test 1F=103mF = 106µF= 109nF = 1012pF
3. For forward voltage drop readings on any semiconductor 0.315A, 250V, fast type fuse, 5x20 mm.
 Pay extra attention to the symbol, before carrying clips, the test clips should be as short as possible and  Discharge all high-voltage capacitors before testing SC
RE
W

To avoid electric shock or personal injury, read the  The internal circuit of the Meter shall not be altered component, place the red test clip on the componentís  Maximum Display: Display: 1999.
measurement, which is located besides the input use the small value jack when measuring small value of capacitance.
"Safety Information" and "Rules for Safety Operation" at will to avoid damage of the Meter and any accident. anode and place the black test clip on the componentís  Measurement Speed: Updates 2-3 times /second.
terminals of the Meter. capacitance.
carefully before using the Meter.  Soft cloth and mild detergent should be used to cathode.  Polarity: Auto. (Display "-" when negative) D. Inductance Test
The display shows the diode forward voltage drop's  The Meter cannot check the quality of the capacitor. (figure 9)
clean the surface of the Meter when servicing. No A. Measuring Resistance (see figure 3)  Overloading: Display "1"
Digital Inductance Capacitance Meter Model UT602/UT603 nearest value.  For large capacitor, please make sure the contact is Accuracy Tested Frequ-
abrasive and solvent should be used to prevent the  Range: Manual Ranging Range Resolution
(hereafter referred to as "the Meter") is a 3 1/2 digits with stable and reliable. ency / Current
surface of the Meter from corrosion, damage and Warning  Temperature: UT602 UT603
steady operations, fashionable design and highly reliable Note  When the tested capacitor is leaking or damaged and o o o o Warning
accident. Operating: 0 C~40 C (32 F ~104 F). 2mH 0.001mH
hand-held measuring instrument. To avoid damages to the Meter or to the devices under the tested value is not stable, the capacitor may have o o o o To avoid electrical shock or arc blast, or personal
 Turn the Meter power off when it is not in use and  In a circuit, a good diode should still produce a forward problems. You need to use other tools or equipment to Storage: -10 C~50 C (14 F~122 F).
test, disconnect circuit power and discharge all the 20mH 0.01mH (2%+8) injury or damage to the Meter, use specified fuses
The UT602 can measure inductance, while UT603 can take out the battery when not using for a long time. voltage drop reading of 500mV to 800mV; however, the  Relative Humidity:
high-voltage capacitors before measuring resistance. check and confirm. o o 1kHz/150µA ONLY in accordance with the following procedure.
measure capacitance and inductance. They both can reverse voltage drop reading can vary depending on the 75% @ 0 C - 30 C; 200mH 0.1mH
 Please constantly check the battery as it may leak The resistance ranges are 20 , 200 , 2k , 20k , 200k , When capacitance measurement has been completed, o To replace the Meter's fuse:
measure resistance, transistor, diode and continuity buzzer resistance of other pathways between the probe tips. 50% @ 31 - 40 C. 2H 0.001H
when it has been using for some time, replace the disconnect the connection between the testing clips and (5%+5) 1. Turn the Meter power off and remove all connections
UT602 has an extra Data Hold feature. 2M , 20M and 2000M .  Connect the test clips to the proper terminals as said
battery as soon as leaking appears. A leaking battery the circuit under test and remove the testing clips away  Altitude: 20H 0.01H from the terminals.
To measure resistance, please connect the Meter as above to avoid error display. The LCD will display "1" (5%+15)
Unpacking Inspection will damage the Meter. from the input terminals of the Meter. Operating: 2000 m. 100Hz/15µA 2. Remove the screw from the battery compartment, and
follows: indicating open-circuit for wrong connection. The unit of 200H 0.1H Reference only separate the battery compartment from the case bottom.
Storage: 10000 m.
International Electrical Symbols 1. Insert the red test clip into the terminal and diode is Volt (V), displaying the positive-connection  Battery Type:One piece of 9V Alkaline (NEDA1604 or 3. Remove the screws from the case bottom, and separate
Open the package case and take out the Meter. Check Remarks:
the black test clip into COM terminal. voltage-drop value. the case top from the case bottom.
the following items carefully to see any missing or damaged 0062 or 6F22 or 006P).  Measure of Inductance: 1H=103mH = 106µΗ.
Grounding 2. Set the rotary switch to range.  When diode test has been completed, disconnect the 4. Remove the fuse by gently prying one end loose, then
part:  Battery Deficiency: Display  Overload Protection: take out the fuse from its bracket.
Double Insulated 3. Connect the test clips across with the object being connection between the testing clips and the circuit under
 Dimensions (HxWxL): 172 x 83 x 38 mm. 0.315A, 250V, fast type fuse, 5x20 mm 5. Install ONLY replacement fuses with the identical type
measured. test and remove the testing clips away from the input
Item Description Qty Deficiency of Built-In Battery.  Weight: Approximate 310g (battery included). and specification as follows and make sure the fuse is
The measured value shows on the display. terminals of the Meter.
1 English Operating Manual 1 piece Continuity Test.  Safety/Compliances: EMC EN61326. fixed firmly in the bracket.
E. Transistor Fuse 1: 0.315A, 250V, fast type fuse, 5x20 mm.
2 Test Clip 1 pair Diode. Note Testing for Continuity  Certification: .
Testing 6. Rejoin the battery compartment and the case top, and
3 9V Alkaline Battery (NEDA1604, 6F22 1 piece Capacitance Test To test for continuity, connect the Meter as below: Accuracy Specifications Range Resolution Remarks reinstall the screw.
 When measuring at 20 and 200 range, the test clips Condition 7. Rejoin the case bottom and case top, and reinstall the
or 006P) (installed) Lx Inductance Test can add 0.1 to 0.3 error to resistance. To obtain precise 1. Insert the red test clip into the terminal and Accuracy: (a% reading + b digits),guarantee for 1 year.
o o The display value is the screws.
Fuse. readings in these low-resistance measurement, that is the black test clip into the COM terminal. Operating temperature: 23 C 5 C. Vce 5.8V Replacement of the fuses is seldom required. Burning of
hFE 1 tested transistor's
In the event you find any missing or damage, please contact the range 20 and 200 , short circuit the input terminals 2. Set the rotary switch to . Relative humidity: < 75%. a fuse always results from improper operation.
Warning. Refer to the Operating Manual. o I bo 10µA (NPN, PNP) nearest
your dealer immediately. beforehand and record the reading obtained (called this 3. Connect the test clips across with the object being Temperature coefficient: 0.1 x (specified accuracy) / 1 C value (0~1000 )
Conforms to Standards of European Union. reading as X). (X) is the additional resistance from the measured. A. Resistance Test ** END **
This operating manual is subject to change without notice.
Safety Information test clips. 4. The beeper comes on continuously when the resistance (figure 6)
The Meter Structure (see figure 1) Accuracy Maintenance
Then use the equation: value of the tested circuit 10 . The beeper may or Range Resolution
This Meter complies with the standards EMC EN61326. 1. LCD Display D. Inductance Measurement (see figure 6) UT602 UT603 This section provides basic maintenance information
measured resistance value (Y) - (X) = precision readings may not come on when the resistance value of the test
Use the Meter only as specified in this operating manual, including battery and fuse replacement instruction.
2. Data Hold (UT602) or L-C switch (UT603) of resistance. circuit>10 To test the inductance, please follow the following procedure: 20 0.01 (1%+5)
otherwise the protection provided by the Meter may be 5. The Meter displays the value of the test resistance.
3. Transistor Jack 1. Set the rotary switch to Lx measurement mode. 200 0.1 (0.8%+3)
impaired.  The Meter displays "1" when there is no input, for Warning
4. Resistance, Diode and Continuity Input Terminal example, open circuit situation. 2. If the tested inductance value is unknown, use the
In this manual, a Warning identifies conditions and actions Note 2k 1
5. Capacitance Input Terminal (UT602) or Capacitance Do not attempt to repair or service your Meter unless
that pose hazards to the user, or may damage the Meter maximum measurement position and decrease the range 20k 10
and Inductance Input Terminal (UT603)  For high resistance measurement (>1M ), it is normal  The LCD displays "1" indicating the circuit being tested (0.8%+1) you are qualified to do so and have the relevant
or the equipment under test. step by step until a satisfactory reading is obtained.
6. Rotary Switch taking several seconds to obtain a stable reading. is open. 200k 100 calibration, performance test, and service information.
A Note identifies the information that user should pay 3. Insert the test clips into the corresponding Lx input
7. Power.  When resistance measurement has been completed,  When continuity test has been completed, disconnect terminals. 2M 1k
attention on. disconnect the connection between the testing clips and the connection between the testing clips and the circuit 4. Use the test clips to clip the inductance to carry out the [2%(rdg-12)+5] To avoid electrical shock or damage to the Meter, do
Functional Buttons 20M 10k
International electrical symbols used on the Meter and in the circuit under test and remove the testing clips away under test and remove the testing clips away from the testing. not get water inside the case.
Below table indicated for information about the functional 2000M 1M Reference only
this Operating Manual are explained on page 7. from the input terminals of the Meter. input terminals of the Meter. 5. The measured value shows on the display.
button operations.