You are on page 1of 1

Important Notes:

S2
• Copyright by Bureau Expo Dubai 2020 (EX20). All rights reserved. This
document may not, in whole or in part, be reproduced, stored, transmitted or
1 2 3 4 5 6 7 8 9 10 distributed in any form or by any means, whether electronic, mechanical, by

5000 5000 5000 5000 5000 5000 5000 5000 5000


SHORING WITH SOLDIER PILING photocopy, recording or otherwise, without the prior written permission of EX20.
Except where otherwise expressly agreed in writing by EX20, EX20 shall have
no responsibility or liability for any loss (direct, consequential or otherwise)
which may arise from reliance on or use of this document or the information
contained therein.
• Where dimensions are not given, drawings must not be scaled and the matter
should be referred back to John R Harris & Partner's.
• This drawing should be read in conjunction with all other project information,
produced by John R Harris & Partner's and others. In the event of any conflict
between the information contained on this drawing and in any other project
A document, drawings, specifications, schedules etc. the matter must be referred
back to John R Harris & Partner's for clarification.
• All dimensions and conditions are to be checked on site by the contractor prior
to preparing designs, shop drawings, calculations etc. or commencing any
5000

work.
• The contractor is responsible for checking that there is no conflict between site
dimensions and drawn dimensions.
• This drawing’s should be read in conjunction with other relevant architectural,
interior design, structural, fire safety, mechanical and electrical drawings and all
relevant sections of the project specifications.
B • The contractor shall submit full shop / setting out drawing for approval (based
on site dimensions) prior to commencement of any site works, placing of
orders, manufacture of fittings, fixtures and components.
• Approved drawings from consultants do not relief the contractors from his
5000

contractual obligations or that of adhering to requirements in accordance with

G
LIN
latest edition of Fire and Life Safety Code of practice and the International

PI
Codes & Standards referred to within where applicable.

R
• Safety, Health and Environment Information: brief details on the identified

IE
LD
hazard symbol referencing the unusual residual hazards / risks are listed

SO
above.
C

ITH
DO NOT SCALE THIS DRAWING.

W
NG
N

I
OR
5000

SH
Makk
ah

D
5000

S1
General Notes
5000

F
5000

G
5000

H
5000

- TYPICAL SECTION

I
No Description

SAFETY, HEALTH AND ENVIRONMENT INFORMATION


Brief details on the identified hazard symbol referencing the unusual residual
5000

hazards / risks are listed above.

J 03 ISSUED FOR CONSTRUCTION AB AB 23/01/2020


02 DETAIL DESIGN AB AB 15/01/2020
01 DETAIL DESIGN AB AB 07/01/2020
0 FOR INFORMATION AB AB 25/12/2019
Rev Description Apvr Chk'd Date
Client

Programme / Programme Management Consultant

Architectural Consultant

S1 SECTION
Project Title

USA PAVILION EXPO 2020


OVERALL PLAN AT FOUNDATION LEVEL Enter address here
Drawing Title
1 : 150
EXCAVATION PLAN

2 SECTION
TYP. DETAIL OF 100 THK. R.C.C. PLANK
(PRECAST) COL-STC1 BEAM-TB1
Approved Seal Date

A.B
Designed Drawn Checked

I.A A.B
Model File Ref: Scale A1(594x841) Revision No
DETAIL-A 6324-USA-ST-M3-001 AS SHOWN 03
PART PLAN OF SOLIDER PILING (SHORING) SECTION A-A Drawing No

6324-USA-ST-DG-ST-1000
6324-USA-ST-DG-ST-1100