You are on page 1of 21

MUHAMMAD ARSLAN SHOUKAT

Electrical & Instrument QA/QC Inspector


Saudi Council Membership No. 452696
Email: arslanshoukatengr@gmail.com
Mobil 055- 6086462 053-0157088

TOTAL PROFESSIONAL WORK EXPERIENCE: 9 YEARS

Career Objective::

To pursue a responsible and challenging career in a growing organization where, I can contribute
and utilize my experience and technical skills, for organizations benefit and growth.

Professional Skills:

 Worked in construction on different position such as


Construction supervisor, QA/QC Inspector I have good
experience in inspection, construction, installation, testing/
pre-commissioning, quality assurance and quality control
(QA/QC

 Both practical as well as theoretical knowledge of Different


Electrical/Equipment/Instruments.
 Strong measuring, testing, troubleshooting and error analyzing skill.
 Fully conversant with Engineering Drawings, Schematic Diagrams, Engineering Standard sand
Quality Control Programs. Experienced in QA/QC Systems and Procedures.
 Knowledge of industry codes and standards related to electrical installation and
 Testing (SAES, SAEP, QMIS, ANSI, ASTM, IEC, IEEE, NEMA and SASO etc.).
 Ability to work with a team of dedicated professionals for achieving the deadlines for the
Execution of work.
 Super vising, training, and development of technicians and support personnel.
 An effective communication with excellent relationship, management skills and strong
Analytical, problem solving and organizational abilities.
 Working more efficiently and productively so that maximum output comes.
 Ability to learn quickly is my forte that has helped me successfully manage various jobs
given.

1|Page
Employment History in KSA:
6. Project : Riyadh Metro

Company : BACS
Clint : Riyadh Metro(RMTC)

Position : QA/QC Electrical Inspector

Duration : April, 2022 to till date

5. Project : King Abdullah Financial District (KAFD)

Company : Saudia Arabian Baytur CO.


Clint : King Abdullah Financial District
Position : QA/QC Electrical Inspector

Duration : August 30, 2020 to 25 March,2022

4. Project : Haradh Gas Compression plant


Company : Technicas Reunidas (TR) Co.
Clint : Saudi Aramco
Position : Electrical Supervisor
Duration : Dec 15, 2019 to August 15, 2020

Responsibilities as follows:

 Perform material take off, procurement support & Coordinate ordering of material and track the progress /
status of material delivery to site.
 Verification of received materials VS ordered material.
 Preparation of method statement for electrical installation and update JSA according to scope of work,
 Review and verify drawings & relevant documents as per scope of work and Support design review
meetings.
 Effectively planned, supervised the execution, monitored and controlled facilities construction projects.
 Review the project technical specification and resolve any discrepancy hindering the project advancement.
 Onsite supervision and monitoring of installation of all major electrical / instrumentation components within
substations include transformers, HV & LV switchgear, control gear, bus-bars, panels and their associated
wiring.
 Determine method of construction, labor needs, material quantities, equipment needs, temporary power
sources, and work schedule for the effective commencement Assist in the reporting of the job’s progress
tothe Project Manager; maintain communication with other departments as required Liaising with the
QA/QCdepartment to ensure that the installation complies with the specified codes and procedures.
 Ensure proper preservation of the material in accordance with the approved project specification and
Vendor's recommendations.
 Collaborate on establishing plan to achieve goal or schedule set by client.
 Meets with Client's technical staff to discuss technical information and feature.
 Participate in constructability review meetings with Subcontractor and Client.
 Generate inspection and test records or coordinate with quality control Construction administration phase,
process shop drawing, responds to RFIs and perform site visit during the construction phase to ensure
project adhering to specifications and design.
 Provided guidance, training, and development of the field electrical and instrumentation personnel and
conduct tool box talk on weekly basis.
 Grounding system Installation, and testing of individual and complete ground grid/loop.

 Duct bank precast installation and perform mandrel test.


 Supervise all activities related to electrical system i.e. installation of cable tray, ladder conduit, boxes,
switches, receptacles & light fixtures.

 Prepare red line & shop drawing for inspection purposes.

 Site surveillance to check the construction work and give comments if necessary, according to standard
project specification.

3. Project : staff housing building hail


Company : Qawaem Al Etihad Est for Contracting
Clint : Saudia Arabia Grains
Position : QA/QC Electrical Inspector
Duration : May 10, 2017 to Nov 20,2019

Responsibilities as follows::

 Attending weekly Activity completion date (ACD) meeting with the client.
 Weekly meeting with construction and client for ongoing issues and non-conformance report.
 Discussion on the daily issue and finding their solution as per Saudi ARAMCO and international
standards.
 To perform the material receiving upon arrival on the site to compliance in accordance with the
approved material requisition, Project specifications, Factory test Certificates, Client material
specifications, inspection forms & ensure that material received at the site are per project
specifications and are from the approved vendor list of the client.
 To verify the latest revision of issued for Construction (IFC) drawings as per the Engineering drawing
register. Verify the controlled copy of the latest project Specifications, approval of the Inspection & Test
Plans (ITP's), Project Quality Plan and Quality system procedures, etc. prior to
 startup of the work ARAMCO Standards, National & International Codes & Standard as NEC,
NFPA, IEEE, IEC, ANSI,NEMA, NETA etc.
 Reporting both verbally & in writing any non-conformance discovered.
 Prepare Non-Conformance Reports for Non-Conformance activities against the approved quality
plans,Inspection test plans & relevant to the client Familiar with Company rules, procedures,
project specification, security and safety levels.
 The witness of Instrument cable continuity & IR test.
 Preparing the necessary documentation (two weeks look ahead the inspection schedule, RFIs,
Inspection Reports, etc.)
 Monitor the Installation of Fire Alarm/Protection System (Addressable).
 Monitor the Installation of Intercom Communication System.
 Site Inspection for the Electrical Installations, Electrical Equipment, Cables Laying, Cable
termination, Indoor & Outdoor lighting Installation as per the approved inspection & test plan.
 Identifying and recording quality problems and opportunities for improvement and initiating or
recommending solutions.
 Witness and verify Continuity, Megger for Low Voltage equipment.
 Supervise and Monitor Installation of Cable, cable tray, Lighting, Distribution Control Panel,
Electrical Equipment and Grounding System, etc.
 Monitoring the inspections & testing and make sure, if it is conducted as per Standard &complying
all the Project specifications.
 Conducts material receiving inspections.
 Prepares and submits Request for Inspection (RFI) on completed works to clients for their approval.
 Review subcontractor or supplier quality document submittals (Quality Plans, Inspection Test
&Plans, procedures), to ensure effective controls are in place in key areas.
 Review Material and Service Requisitions bid tabs (including QA evaluation of bids),
Subcontracts and Purchase Orders.
 Monitoring and reporting on the status of implementation of the Project Quality
ManagementSystem and its effectiveness.
 Check and review construction/installation sketches and/or shop drawings ensure that
thesketches/drawings conform to the project specifications and standards.
 Coordinates with the client representatives on matters involving quality assurance and
controlactivities.
 Monitor the Installation of CCTV Security Camera Network.
 Supervision of MV/LV cable laying.
 Installation Inspection and termination of 20,000 meter MV cable.
 Installation Inspection and termination of 25,000 meter LV cable.

Employment History in Pakistan:

2. Project : Building Facility.

Company : UOL Contracting Co.

Clint : University of Lahore Pakistan

Position : QA/QC E & I Inspector

Duration : March, 2014 to December, 2016

Responsibilities as follows:

 Responsible for the over-all implementation of Quality Control related works


accordance with project specifications and Engineering Standards.
 Review and Inspection of all Electrical Material, prior to installation.
 Verify the equipment and devices used in the project meets the required specifications
as per project requirements.
 Monitor the Installation of CCTV Security Camera Network.
 Monitor the Installation of Fire Alarm/Protection System (Addressable).
 Preparation of Electrical inspection reports.
 Coordinate with the Client representative regarding the implementation and quality of
works.
 Site Inspection for the Electrical Installations, Electrical Equipment Installation as per
the approved inspection & test plan.
 Identifying and recording quality problems and opportunities for improvement and
initiating or recommending solutions.
 Issue Technical Query(TQ) if found some design drawing are need to change or modify
and apply all the Engineering Standard that Client required.

1. Company : Allied Engineering & Services (PVT) Ltd.


Position : Power House Plant Operator
Duration : December 2012 to January, 2014

Responsibilities as follows:

 Conduct inspection during equipment maintenance.


 Support equipment start up and shutdown.
 Lubricate equipment and machinery
 Engage in educational training and safety programs.
 Handle control room operator
 Oversee and check power plant equipment to determine operating problems evidence.
 Refill electrolyte in batteries and oil in voltage transformers and reset tripped electric
relays.
 Handle generators, auxiliary pumping equipment and power plant devices to connect or
disconnect equipment from circuits
 Gather oil, water and electrolyte samples of lab analysis.
 Interact with systems operations to coordinate transmission loads, frequencies and line
voltages.
 Document and compile operational data, complete and maintain forms, logs and
reports.

EDUCATION PROFILE/CERTIFICATION:

 3 Years Diploma of Associate Engineer from GCT Bahawalpur (PBTE) Lahore.


 NFPA

COMPUTER SKILL SET and CERTIFICATION :

 Auto CAD, Microsoft word, Excel & Internet Explorer etc.


 NFPA Certifications

LANGUAGE SKILLS:

English, Urdu, and some Arabic


PERSONAL INFORMATION:

Father’s Name : Shoukat Mahmood


Nationality : Pakistan
Marital Status : Single
Relegion : Islam
Driving License : Saudi Valid
Visa Status : Work visa (Transferable)

You might also like