First order multiplexer subrack 3AL 42923

ABXX
not permitted without written authorization from Alcatel.
document, use and communication of its contents
All rights reserved. Passing on and copying of this

1 Function
This subrack has 17 positions for plug-in units and can be equipped with the necessary
units to build 1 complete first order multiplexer system. It is power-fed from the AC mains
by means of an AC/DC converter.

2 Front view

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

Test Test LMP Q2

Alarm Lamp driver Q2LTS Manage


ment bus
Cable to Cable to
next subrack previous subrack
Test bus extension (option)

DOCC: *NA
MMCC: *NA
20031010

3AL 42923 ABAA TNAAA Edition 05 1 / 10


3AL 42923 First order multiplexer subrack
ABXX

not permitted without written authorization from Alcatel.


document, use and communication of its contents
All rights reserved. Passing on and copying of this
3 Subrack equipment
The subrack is equipped as follows :
 1 (main) AC/DC converter in position 8/9;
 1 redundant AC/DC converter in position 6/7 (option);
 1 (master) PCMC unit in position 15;
 1 CNCC unit in position 16 (option);
 1 Q1 extension unit QEXA in position 17 (option);
 the positions 1 to 7 and/or 10 to 14 can be equipped with the necessary CSU's to
build 1 multiplexer system :
 the CSU's in position 10 to 14 are connected to the internal bus 1;
 the CSU's in position 1 to 7 are connected to the internal bus 2.
Remarks :
 in case of channel drop and insert, a slave PCM controller unit can be mounted in any
position if it is addressable by the CNCC : refer to Setting of system addresses.
 the subrack is primarily intended to be used with channel units (CSU's) with 3 channels
per unit (or occupying 3 time slots on the internal bus). However, other channel units
can be mounted as well. Channel units with different signalling types can be
combined in one subrack.
 when the channels on the CSU's occupy more than 30 time slots, at least one CSU
should be placed in such a position that the corresponding channels are connected to
bus 2. In this way the system configuration can be adapted, if required, by means of
man-machine commands only and without the need to rearrange the subrack layout.
 an integrated line test unit ILTAUS can be mounted in any position if it is addressable
by the CNCC : refer to Setting of system addresses.
 auxiliary units, if required, can be placed on any of the remaining places.
 In case 1511BA with clock protection the slave PCMC controller unit can be mounted
in position13 or 14.

4 Connectors on the backpanel of the subrack

Test
2 connectors for the through-connection between subracks of the test bus (daisy-chain
principle) :
Meaning :
 TPCM system : Signal 3 - 4 : not connected

2 / 10 3AL 42923 ABAA TNAAA Edition 05


First order multiplexer subrack 3AL 42923
ABXX
not permitted without written authorization from Alcatel.
document, use and communication of its contents
All rights reserved. Passing on and copying of this

01 : Not connected
06 : Not connected
02 : SL3 : Signal 3
07 : Not connected
03 : SL4 : Signal 4
08 : Not connected
04 : Not connected
09 : Not connected
05 : Not connected
 SPCM system :
 Signal 3 : TBA : test bus A-wire
 Signal 4 : TBB : test bus B-wire

LMP

06 : Not connected 01 : Not connected


07 : Not connected 02 : NUALLMP
08 : Not connected 03 : UALLMP
09 : Not connected 04 : EXTALLMP
05 : BATTF

This connector can be used with the cable 3AL 42877 AAAA to connect the lamps on top of
the rack.

Q2

Q2 interface connector (only if a CNCC is provided in position 16) :

08 : Not connected
15 : Not connected
07 : Not connected
14 : Not connected
06 : Clock in (+)
13 : Clock in (-)
05 : Not connected
12 : Electrical ground
04 : Data out (+)
11 : Data out (-)
03 : Not connected
10 : Electrical ground
02 : Data in (+)
09 : Data in (-)
01 : Safety ground
Q2 interface of CNCC (if provided on the subrack) : can be connected to the top block via
a cable 3AL 42734

5 Switch settings on the backpanel


The switches on the backpanel of the subrack are shown on figure 2. They can only be
reached if no units are mounted on the subrack.
The DIL switches S701 and S702 can be used to set the Q1 bus addresses for the systems
on the subrack, see Setting of the system addresses.
The switch S700 has to be set according to the equipped unit in position 16 of the subrack
: CNCC or not (PWR).

3AL 42923 ABAA TNAAA Edition 05 3 / 10


3AL 42923 First order multiplexer subrack
ABXX

not permitted without written authorization from Alcatel.


document, use and communication of its contents
All rights reserved. Passing on and copying of this
CLK 123

F X264
A
X266

Master Slave

E S678

S301 S401
D 1 1
2 2
3 3
4 4
5 5
GND 6 6
7 7
Open OUT IN 8 8
S246 ON S402ON
S7001 75Ω 120Ω 120 75Ω S302
S268 Ω
1 1
S286 S262 3
2 2
3
4 4 B
S285 ON ON
C S222 S524
S510
S221 64K 1200

Figure 1 Position of the straps on the QEXA board

4 / 10 3AL 42923 ABAA TNAAA Edition 05


First order multiplexer subrack 3AL 42923
ABXX
not permitted without written authorization from Alcatel.
document, use and communication of its contents
All rights reserved. Passing on and copying of this

6 Setting of the system addresses


1 multiplexer system can be mounted on this subrack. The Q1 bus addresses for the
system on the subrack are set by means of switches on the QEXA unit in position 17. For
some general information, refer to section 3 of the manual : installation.

Note The addresses can also be set by means of switches on the backpanel of the
subrack : however, this method can only be used on the following conditions :
 the CNCC is mounted on the subrack;
 there is no need to extend the Q1 bus to other subracks;
 the other functionalities of the QEXA unit (access for synchronization clock
input or output, access for auxiliary alarm inputs) are not required.

If the address setting is realized by means of the switches on the QEXA unit, all
ATTENTION switches on the backpanel of the subrack have to be open.

7 System address setting by means of QEXA


The addressing is realized by means of the switches S301 and S302 (Enable A) and S401
and S402 (Enable B) on the QEXA unit (see figure 1).
This subrack enables different exploitation modes :
 in the normal exploitation 4 units of the multiplexer system can be addressed;
 an extended exploitation makes it possible to address 8 units or all units on the
subrack.

Normal exploitation
4 consecutive numbers (within the same group of 8) are assigned to the subrack. Selection
is achieved by setting 5 switches in the ON position :
 one switch of S301 is set to ON to select a group of 8 addresses (the other switches of
S301 and all switches of S302 are set to OFF);
 the first 4 switches of S401 are set to ON if the first 4 addresses of the group have to
be used (the other switches of S401 and all switches of S402 are set to OFF);
 the 4 switches of S402 are set to ON if the last 4 addresses of the group have to be
used (all switches of S401 are set to OFF).

3AL 42923 ABAA TNAAA Edition 05 5 / 10


3AL 42923 First order multiplexer subrack
ABXX

not permitted without written authorization from Alcatel.


document, use and communication of its contents
All rights reserved. Passing on and copying of this
Example : system addresses 17 to 20 Value Value
0 1 1 1
 address 17 = 16 + 1 = position S301 : 3 and S401 :1 8 2 2 2
16 3 3 3
 address 20 = 16 + 4 = position S301 : 3 and S401 :4 24 4 4 4
S301 32 5 5 5 S401
40 6 6 6
48 7 7 7
56 8 8 8

Value Value
8 1 1 5
24 2 2 6
S302 0 3 3 7 S402
16 4 4 8

Example : system addresses 21 to 24 Value Value


0 1 1 1
 address 21 = 16 + 5 = position S301 : 3 and S402 :1 8 2 2 2
16 3 3 3
 address 24 = 16 + 8 = position S301 : 3 and S402 :4 24 4 4 4
S301 32 5 5 5 S401
40 6 6 6
48 7 7 7
56 8 8 8

Value Value
8 1 1 5
24 2 2 6
S302 0 3 3 7 S402
16 4 4 8

The addresses are assigned to the units on the subrack as follows :


 the 1st address belongs to the PCM controller unit in position 15 and the main AC/DC
converter in position 8/9;
 the 2nd address belongs to the unit in position 1 and the redundant AC/DC converter
in position 6/7, if provided;
 the 3rd address belongs to the unit in position 14;
 the 4th address belongs to the unit in position 2.
The unit in position 1, 2 and 14 can be a Slave PCM controller or ILTAUS.

Extended addressing exploitation with 8 addresses


8 consecutive numbers (i.e. 1 group of 8) are assigned to the subrack. Selection is
achieved by setting 9 switches in the ON position :

6 / 10 3AL 42923 ABAA TNAAA Edition 05


First order multiplexer subrack 3AL 42923
ABXX
not permitted without written authorization from Alcatel.
document, use and communication of its contents
All rights reserved. Passing on and copying of this

 one switch of S301 is set to ON to select a group of 8 addresses (the other switches of
S301 and all switches of S302 are set to OFF);
 all 8 switches of S401 are set to ON (all switches of S402 are set to OFF).
Example : system addresses 17 to 24 Value Value
0 1 1 1
 address 17 = 16 + 1 = position S301 : 3 and S401 :1 8 2 2 2
16 3 3 3
 address 24 = 16 + 8 = position S301 : 3 and S401 : 8 24 4 4 4
S301 32 5 5 5 S401
40 6 6 6
48 7 7 7
56 8 8 8

Value Value
8 1 1 5
24 2 2 6
S302 0 3 3 7 S402
16 4 4 8

The addresses are assigned to the units on the subrack as follows :


 the 1st address belongs to the PCM controller unit in position 15 and the main AC/DC
converter in position 8/9;
 the 2nd address belongs to the unit in position 1 and the redundant AC/DC converter
in position 6/7, if provided;
 the 3rd address belongs to the unit in position 14;
 the 4th address belongs to the unit in position 2;
 the 5th address belongs to the unit in position 13;
 the 6th address belongs to the unit in position 3;
 the 7th address belongs to the unit in position 12;
 the 8th address belongs to the unit in position 4.
The unit in position 1, 2, 3, 4, 12, 13 and 14 can be a Slave PCM controller or ILTAUS.

Extended addressing exploitation with 16 addresses


16 numbers (i.e. 2 groups of 8 consecutive numbers) are assigned to the subrack.
Selection is achieved by setting 10 switches in the ON position :
 one switch of S301and one switch of S302 are set to ON to select a group of 8
addresses (the other switches of S301 and of S302 are set to OFF);
 all 8 switches of S401 are set to ON (all switches of S402 are set to OFF).

3AL 42923 ABAA TNAAA Edition 05 7 / 10


3AL 42923 First order multiplexer subrack
ABXX

not permitted without written authorization from Alcatel.


document, use and communication of its contents
All rights reserved. Passing on and copying of this
Take care to select different groups by means of the switches of S301 and
ATTENTION S302.

As the switches of S302 can only select addresses below 32, it can be
TIP appropriate to select the addresses above 32 with the switches of S301.

Example : system addresses 1 to 8 and 33 to 40 Value Value


0 1 1 1
 address 1 = 0 + 1 = position S302 : 3 and S401 : 1 8 2 2 2
16 3 3 3
 address 8 = 0 + 8 = position S302 : 3 and S401 : 8 24 4 4 4
S301 32 5 S401
 address 33 = 32 + 1 = position S301 : 5 and S401 : 1 5 5
40 6 6 6
 address 40 = 32 + 8 = position S301 : 5 and S401 : 8 48 7 7 7
56 8 8 8

Value Value
8 1 1 5
24 2 2 6
S302 0 3 3 7 S402
16 4 4 8

The addresses are assigned to the units on the subrack as follows :


 group of addresses selected with S301 :
 the 1st address belongs to the PCM controller unit in position 15 and the main
AC/DC converter in position 8/9;
 the 2nd address belongs to the unit in position 1 and the redundant AC/DC
converter in position 6/7, if provided;
 the 3rd address belongs to the unit in position 14;
 the 4th address belongs to the unit in position 2;
 the 5th address belongs to the unit in position 13;
 the 6th address belongs to the unit in position 3;
 the 7th address belongs to the unit in position 12;
 the 8th address belongs to the unit in position 4;
 group of addresses selected with S301 :

8 / 10 3AL 42923 ABAA TNAAA Edition 05


First order multiplexer subrack 3AL 42923
ABXX
not permitted without written authorization from Alcatel.
document, use and communication of its contents
All rights reserved. Passing on and copying of this

 the 1st address belongs to the unit in position 11;


 the 2nd address belongs to the unit in position 5;
 the 3rd address belongs to the unit in position 10;
 the 4th address belongs to the unit in position 6;
 the 5th address belongs to the unit in position 9 (not used);
 the 6th address belongs to the unit in position 7;
 the 7th address is not used;
 the 8th address is not used.
The unit in position 1 to 7 and 10 to 14 can be a Slave PCM controller or ILTAUS.

8 System address setting by means of backpanel switches


The addressing is realized by means of the switches S702 (Enable A) an S701 (Enable B)
on the backpanel of the subrack (see figure 2).
By closing all switches on S701 and S702, the addresses 1 to 16 are assigned to the units
of the subrack in the following way :
 address 1 belongs to the PCM controller unit in position 15 and the main AC/DC
converter in position 8/9;
 address 2 belongs to the unit in position 1 and the redundant AC/DC converter in
position 6/7, if provided;
 address 3 belongs to the unit in position 14;
 address 4 belongs to the unit in position 2;
 address 5 belongs to the unit in position 13;
 address 6 belongs to the unit in position 3;
 address 7 belongs to the unit in position 12;
 address 8 belongs to the unit in position 4;
 address 9 belongs to the unit in position 11;
 address 10 belongs to the unit in position 5;
 address 11 belongs to the unit in position 10;
 address 12 belongs to the unit in position 6;
 address 13 belongs to the unit in position 9 (not used);
 address 14 belongs to the unit in position 7;
 address 15 is not used;
 address 16 is not used.
The unit in position 1 to 7 and 10 to 14 can be a Slave PCM controller or ILTAUS.

3AL 42923 ABAA TNAAA Edition 05 9 / 10


3AL 42923 First order multiplexer subrack
ABXX

not permitted without written authorization from Alcatel.


document, use and communication of its contents
All rights reserved. Passing on and copying of this
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

S700
CNCC PWR

Test Test LMP Q2

S701
1
2
3
4

S702 ON
If the address setting is realized on
1
2
3
the QEXA unit, these switches have 4
5
6
to be open (as shown) !! 7
8
ON

Figure 2 Position of the straps on the backpanel of the subrack

10 / 10 3AL 42923 ABAA TNAAA Edition 05