First order multiplexer subrack 3AL 42914

ADXX
not permitted without written authorization from Alcatel.
document, use and communication of its contents
All rights reserved. Passing on and copying of this

1 Function
This subrack has 17 positions for plug-in units and can be equipped with the necessary
units to build 2 complete first order multiplexer systems.
This variant is the non-EMC version of the subrack and can be used with board variants
without EMC frontplates (except the QEXA card), but equipped with stiffeners instead.

DOCC: *NA
MMCC: *NA
20031010

3AL 42914 ADAA TNAAA Edition 03 1 / 14


3AL 42914 First order multiplexer subrack
ADXX

not permitted without written authorization from Alcatel.


document, use and communication of its contents
All rights reserved. Passing on and copying of this
2 Front view

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

Test Test LMP Q2

Q2LTS Manage
Alarm Lamp driver ment bus
Cable to Cable to Power cable to
next subrack previous subrack distribution
Test bus extension (option)

3 Subrack equipment
The subrack is equipped as follows :
 1 (main) ringer/power unit in position 8;
 1 redundant ringer/power unit in position 7 (option);
 1 CNCC unit in position 16 (option);
 1 Q1 extension unit QEXA in position 17 (option);
 the other positions can be equipped with the necessary units to build 2 multiplexer
systems, as indicated below.
Multiplexer 1 is equipped in the positions 1 to 7 :

2 / 14 3AL 42914 ADAA TNAAA Edition 03


First order multiplexer subrack 3AL 42914
ADXX
not permitted without written authorization from Alcatel.
document, use and communication of its contents
All rights reserved. Passing on and copying of this

 1 (master) PCMC unit in position 1;


 the CSU's are mounted in the positions 2 to 7 :
 the CSU's in position 2 to 4 are connected to the internal bus 1;
 the CSU's in position 5 to 7 are connected to the internal bus 2.
Multiplexer 2 is equipped in the positions 9 to 15 :
 1 (master) PCMC unit in position 15;
 the CSU's are mounted in the positions 9 to 14 :
 the CSU's in position 12 to 14 are connected to the internal bus 1;
 the CSU's in position 9 to 11 are connected to the internal bus 2.
Remarks :
 if the CNCC (in position 16) is not equipped, a redundant ringer/power unit can be
mounted in this position.
 in case of channel drop and insert, a slave PCM controller unit can be mounted in any
position if it is addressable by the CNCC : refer to Setting of system addresses.
 the subrack is primarily intended to be used with channel units (CSU's) with 5 channels
per unit (or occupying 5 time slots on the internal bus). However, other channel units
can be mounted as well. Channel units with different signalling types can be
combined in one subrack and in one multiplexer.
 when the channels on the CSU's occupy more than 30 time slots, at least one CSU
should be placed in such a position that the corresponding channels are connected to
bus 2. In this way the system configuration can be adapted, if required, by means of
man-machine commands only and without the need to rearrange the boards in the
subrack.
 an integrated line test unit ILTAUS can be mounted in any position if it is addressable
by the CNCC : refer to Setting of system addresses.
 auxiliary units, if required, can be placed on any of the remaining places.
 In case 1511BA with clock protection a slave PCM controller unit can be mounted:
 in position 2 or 3 for multiplexer 1
 in position 13 or 14 for multiplexer 2

3AL 42914 ADAA TNAAA Edition 03 3 / 14


3AL 42914 First order multiplexer subrack
ADXX

not permitted without written authorization from Alcatel.


document, use and communication of its contents
All rights reserved. Passing on and copying of this
4 Connectors on the backpanel of the subrack

Test
2 connectors for the through-connection between subracks of the test bus (daisy-chain
principle) :
01 : Not connected
06 : Not connected
02 : SL3 : Signal 3
07 : Not connected
03 : SL4 : Signal 4
08 : Not connected
04 : Not connected
09 : Not connected
05 : Not connected
Meaning :
 TPCM system : Signal 3 - 4 : not connected
 SPCM system :
 Signal 3 : TBA : test bus A-wire
 Signal 4 : TBB : test bus B-wire

LMP

06 : Not connected 01 : Not connected


07 : Not connected 02 : NUALLMP
08 : Not connected 03 : UALLMP
09 : Not connected 04 : EXTALLMP
05 : BATTF

This connector can be used with the cable 3AL 42877 AAAA to connect the lamps on top of
the rack.

Q2
Q2 interface connector (only if a CNCC is provided in position 16) :

08 : Not connected
15 : Not connected
07 : Not connected
14 : Not connected
06 : Clock in (+)
13 : Clock in (-)
05 : Not connected
12 : Electrical ground
04 : Data out (+)
11 : Data out (-)
03 : Not connected
10 : Electrical ground
02 : Data in (+)
09 : Data in (-)
01 : Safety ground

POWER
Power supply connector, connected to the power distribution via a connection cable 3AL
42732.

4 / 14 3AL 42914 ADAA TNAAA Edition 03


First order multiplexer subrack 3AL 42914
ADXX
not permitted without written authorization from Alcatel.
document, use and communication of its contents
All rights reserved. Passing on and copying of this

B B B
A A A
T T T
2 R 1

BATR is connected internally to PE

5 Power unit
The power unit is used to :
 interrupt the power supply (BAT1 and BAT2).
 protect the boards in this subrack from transients and surges on the battery power
supplies.

Specifications of the circuit breakers


The unit is equipped with circuit breakers on the BAT1 and BAT2 voltages with following
specifications :
 Current rating : 5 A
 Maximum resistance : 30 mΩ
 Nominal voltage rating : 72 VDC
 Short circuit breaking capacity : 1000 A at 72 VDC
 Isolation resistance : 100 MΩ at 500 VDC
 Dielectric strenght : 2kV AC

6 Switch settings on the backpanel


The switches on the backpanel of the subrack are shown on figure 2. They can only be
reached if no units are mounted on the subrack.
The DIL switches S701 and S702 are used to set the Q1 bus addresses if no QEXA board is
equipped in the subrack:
 If a QEXA board is equipped in the subrack, S701 and S702 must be set in the OFF
position.
 If no QEXA board is equipped in the subrack, S701 and S702 must be set in the ONN
position.
The switch S700 has to be set according to the equipped unit in position 16 of the subrack
: CNCC or redundant ringer/power (PWR).

3AL 42914 ADAA TNAAA Edition 03 5 / 14


3AL 42914 First order multiplexer subrack
ADXX

not permitted without written authorization from Alcatel.


document, use and communication of its contents
All rights reserved. Passing on and copying of this
7 Setting of the system addresses
2 multiplexer systems can be mounted on this subrack. The Q1 bus addresses for the
systems on the subrack are set by means of switches on the QEXA unit in position 17. For
some general information, refer to section 3 of the manual : installation.

Note The addresses can also be set by means of switches on the backpanel of the
subrack : however, this method can only be used on the following conditions :
 the CNCC is mounted on the subrack;
 there is no need to extend the Q1 bus to other subracks;
 the other functionalities of the QEXA unit (access for synchronization clock
input or output, access for auxiliary alarm inputs) are not required.

If the address setting is realized by means of the switches on the QEXA unit, all
ATTENTION switches on the backpanel of the subrack have to be open.

6 / 14 3AL 42914 ADAA TNAAA Edition 03


First order multiplexer subrack 3AL 42914
ADXX
not permitted without written authorization from Alcatel.
document, use and communication of its contents
All rights reserved. Passing on and copying of this

CLK 123

F X264
A
X266

Master Slave

S678
E

S301 S401
D 1 1
2 2
3 3
4 4
5 5
GND 6 6
7 7
Open OUT IN 8 8
S246 ON S402ON
S7001 75Ω 120Ω 120 75Ω S302
S268 Ω
1 1
S286 S262 3
2 2
3
4 4 B
S285 ON ON
C S222 S524
S510
S221 64K 1200

Figure 1 Position of the straps on the QEXA board

3AL 42914 ADAA TNAAA Edition 03 7 / 14


3AL 42914 First order multiplexer subrack
ADXX

not permitted without written authorization from Alcatel.


document, use and communication of its contents
All rights reserved. Passing on and copying of this
8 System address setting by means of QEXA
The addressing is realized by means of the switches S301 and S302 (Enable A) and S401
and S402 (Enable B) on the QEXA unit (see figure 1).
This subrack enables different exploitation modes :
 in the normal exploitation 2 units of each multiplexer system can be addressed;
 an extended exploitation makes it possible to address 4 units of each multiplexer
system or all units on the subrack.
Normal exploitation
4 consecutive numbers (within the same group of 8) are assigned to the subrack (so 4
addresses per subrack). Selection is achieved by setting 5 switches in the ON position :
 one switch of S301 is set to ON to select a group of 8 addresses (the other switches of
S301 and all switches of S302 are set to OFF);
 the first 4 switches of S401 are set to ON if the first 4 addresses of the group have to
be used (the other switches of S401 and all switches of S402 are set to OFF);
 the 4 switches of S402 are set to ON if the last 4 addresses of the group have to be
used (all switches of S401 are set to OFF).
Example : system addresses 17 to 20 Value OFF ON OFF ON Value
0 1 1 1
 address 17 = 16 + 1 = position S301 : 3 and S401 : 1 8 2 2 2
16 3
 address 20 = 16 + 4 = position S301 : 3 and S401 : 4 24 4 3 3
4 4
S301 32 5 5 5 S401
40 6 6 6
48 7 7 7
56 8 8 8

Value Value
8 1 1 5
24 2 2 6
S302 0 3 3 7 S402
16 4 4 8

Example : system addresses 21 to 24 Value OFF ON OFF ON Value


0 1 1 1
 address 21 = 16 + 5 = position S301 : 3 and S402 : 1 8 2 2 2
16 3
 address 24 = 16 + 8 = position S301 : 3 and S402 : 4 24
3
4
3
4 4
S301 32 5 5 5 S401
40 6 6 6
48 7 7 7
56 8 8 8

Value Value
8 1 1 5
24 2 2 6
S302 0 3 3 7 S402
16 4 4 8

8 / 14 3AL 42914 ADAA TNAAA Edition 03


First order multiplexer subrack 3AL 42914
ADXX
not permitted without written authorization from Alcatel.
document, use and communication of its contents
All rights reserved. Passing on and copying of this

The addresses are assigned to the units on the subrack as follows :


 the 1st address belongs to the PCM controller unit in position 15 (2nd multiplexer) and
the main ringer power unit RGPA in position 8;
 the 2nd address belongs to the PCM controller unit in position 1 (1st multiplexer) and
the redundant ringer power unit RGPA in position 7 or 16, if provided;
 the 3rd address belongs to the unit in position 14 (Slave PCM controller of 2nd
multiplexer or ILTAUS);
 the 4th address belongs to the unit in position 2 (Slave PCM controller of 1st
multiplexer or ILTAUS).

Extended addressing exploitation with 8 addresses


8 consecutive numbers (i.e. 1 group of 8) are assigned to the subrack. Selection is
achieved by setting 9 switches in the ON position :
 one switch of S301 is set to ON to select a group of 8 addresses (the other switches of
S301 and all switches of S302 are set to OFF);
 all 8 switches of S401 are set to ON (all switches of S402 are set to OFF).
Example : system addresses 17 to 24 Value OFF ON OFF ON Value
0 1 1 1
 address 17 = 16 + 1 = position S301 : 3 and S401 : 1 8 2 2 2
16 3 3 3
 address 24 = 16 + 8 = position S301 : 3 and S401 : 8 24 4 4 4
S301 32 5 5 5 S401
40 6 6 6
48 7 7 7
56 8 8 8

Value Value
8 1 1 5
24 2 2 6
S302 0 3 3 7 S402
16 4 4 8

The addresses are assigned to the units on the subrack as follows :

3AL 42914 ADAA TNAAA Edition 03 9 / 14


3AL 42914 First order multiplexer subrack
ADXX

not permitted without written authorization from Alcatel.


document, use and communication of its contents
All rights reserved. Passing on and copying of this
 the 1st address belongs to the PCM controller unit in position 15 (2nd multiplexer) and
the main ringer power unit RGPA in position 8;
 the 2nd address belongs to the PCM controller unit in position 1 (1st multiplexer) and
the redundant ringer power unit RGPA in position 7 or 16, if provided;
 the 3rd address belongs to the unit in position 14 (Slave PCM controller of 2nd
multiplexer or ILTAUS);
 the 4th address belongs to the unit in position 2 (Slave PCM controller of 1st
multiplexer or ILTAUS);
 the 5th address belongs to the unit in position 13 (Slave PCM controller of 2nd
multiplexer or ILTAUS);
 the 6th address belongs to the unit in position 3 (Slave PCM controller of 1st
multiplexer or ILTAUS);
 the 7th address belongs to the unit in position 12 (Slave PCM controller of 2nd
multiplexer or ILTAUS);
 the 8th address belongs to the unit in position 4 (Slave PCM controller of 1st
multiplexer or ILTAUS).

Extended addressing exploitation with 16 addresses


16 numbers (i.e. 2 groups of 8 consecutive numbers) are assigned to the subrack.
Selection is achieved by setting 10 switches in the ON position :
 one switch of S301and one switch of S302 are set to ON to select a group of 8
addresses (the other switches of S301 and of S302 are set to OFF);
 all 8 switches of S401 are set to ON (all switches of S402 are set to OFF).

Take care to select different groups by means of the switches of S301 and
ATTENTION S302.

As the switches of S302 can only select addresses below 32, it can be
TIP appropriate to select the addresses above 32 with the switches of S301.

10 / 14 3AL 42914 ADAA TNAAA Edition 03


First order multiplexer subrack 3AL 42914
ADXX
not permitted without written authorization from Alcatel.
document, use and communication of its contents
All rights reserved. Passing on and copying of this

Example : system addresses 1 to 8 and 33 to 40 Value OFF ON OFF ON Value


0 1 1 1
 address 1 = 0 + 1 = position S302 : 3 and S401 : 1 8 2 2 2
16 3
 address 8 = 0 + 8 = position S302 : 3 and S401 : 8 24
3
4
3
4 4
 address 33 = 32 + 1 = position S301 : 5 and S401S301
: 1 32 5 5 5 S401
 address 40 = 32 + 8 = position S301 : 5 and S401 : 8 4048
6
7
6
7
6
7
56 8 8 8

Value Value
8 1 1 5
24 2 2 6
S302 0 3 3 7 S402
16 4 4 8

The addresses are assigned to the units on the subrack as follows :


 group of addresses selected with S301 :
 the 1st address belongs to the PCM controller unit in position 15 (2nd multiplexer)
and the main ringer power unit RGPA in position 8;
 the 2nd address belongs to the PCM controller unit in position 1 (1st multiplexer)
and the redundant ringer power unit RGPA in position 7 or 16, if provided;
 the 3rd address belongs to the unit in position 14; *2
 the 4th address belongs to the unit in position 2; *1
 the 5th address belongs to the unit in position 13; *2
 the 6th address belongs to the unit in position 3; *1
 the 7th address belongs to the unit in position 12; *2
 the 8th address belongs to the unit in position 4; *1
 group of addresses selected with S301 :
 the 1st address belongs to the unit in position 11; *2
 the 2nd address belongs to the unit in position 5; *1
 the 3rd address belongs to the unit in position 10; *2
 the 4th address belongs to the unit in position 6; *1
 the 5th address belongs to the unit in position 9; *2
 the 6th address belongs to the unit in position 7; *1
 the 7th address belongs to the unit in position 8; *2
 the 8th address is not used.
Note *1 : this can be a Slave PCM controller of multiplexer 1 or an ILTAUS;
*2 : this can be a Slave PCM controller of multiplexer 2 or an ILTAUS.

9 System address setting by means of backpanel switches


The addressing is realized by means of the switches S702 (Enable A) an S701 (Enable B)
on the backpanel of the subrack (see figure 2).

3AL 42914 ADAA TNAAA Edition 03 11 / 14


3AL 42914 First order multiplexer subrack
ADXX

not permitted without written authorization from Alcatel.


document, use and communication of its contents
All rights reserved. Passing on and copying of this
If no QEXA board is equipped, all switches of S701 and S702 must be closed. The
addresses 1 to 16 are assigned to the units of the subrack in the following way :
 address 1 belongs to the PCM controller unit in position 15 (2nd multiplexer) and the
main ringer power unit RGPA in position 8;
 address 2 belongs to the PCM controller unit in position 1 (1st multiplexer) and the
redundant ringer power unit RGPA in position 7 or 16, if provided;
 address 3 belongs to the unit in position 14; *2
 address 4 belongs to the unit in position 2; *1
 address 5 belongs to the unit in position 13; *2
 address 6 belongs to the unit in position 3; *1
 address 7 belongs to the unit in position 12; *2
 address 8 belongs to the unit in position 4; *1
 address 9 belongs to the unit in position 11; *2
 address 10 belongs to the unit in position 5; *1
 address 11 belongs to the unit in position 10; *2
 address 12 belongs to the unit in position 6; *1
 address 13 belongs to the unit in position 9; *2
 address 14 belongs to the unit in position 7; *1
 address 15 belongs to the unit in position 8; *2
 address 16 is not used.

Note *1 : this can be a Slave PCM controller of multiplexer 1 or an ILTAUS;


*2 : this can be a Slave PCM controller of multiplexer 2 or an ILTAUS.

12 / 14 3AL 42914 ADAA TNAAA Edition 03


First order multiplexer subrack 3AL 42914
ADXX
not permitted without written authorization from Alcatel.
document, use and communication of its contents
All rights reserved. Passing on and copying of this

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

S700
CNCC PWR

Test Test LMP Q2

OFF ON
1
2
S701
If the address setting is realized on
3
4

the QEXA unit, these switches have OFF ON


1
to be open (as shown) !! 2
3
S702 4
5
6
7
8

Figure 2 Position of the straps on the backpanel of the subrack

3AL 42914 ADAA TNAAA Edition 03 13 / 14


14 / 14
ADXX
3AL 42914
First order multiplexer subrack

3AL 42914 ADAA TNAAA


Edition 03
All rights reserved. Passing on and copying of this
document, use and communication of its contents
not permitted without written authorization from Alcatel.