1 Function
This subrack has 17 positions for plug-in units and can be equipped with the necessary
units to build up to 3 complete first order multiplexer systems.
2 Front view
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
3 Subrack equipment
The subrack is equipped as follows :
DOCC: *NA
MMCC: *NA
20031010
Test
2 connectors for the through-connection between subracks of the test bus (daisy-chain
principle) :
01 : Not connected
06 : Not connected
02 : SL3 : Signal 3
07 : Not connected
03 : SL4 : Signal 4
08 : Not connected
04 : Not connected
09 : Not connected
05 : Not connected
Meaning :
TPCM system : Signal 3 - 4 : not connected
SPCM system :
Signal 3 : TBA : test bus A-wire
Signal 4 : TBB : test bus B-wire
LMP
This connector can be used with the cable 3AL 42877 AAAA to connect the lamps on top of
the rack.
08 : Not connected
15 : Not connected
07 : Not connected
14 : Not connected
06 : Clock in (+)
13 : Clock in (-)
05 : Not connected
12 : Electrical ground
04 : Data out (+)
11 : Data out (-)
03 : Not connected
10 : Electrical ground
02 : Data in (+)
09 : Data in (-)
01 : Safety ground
PS
Power supply connector, connected to the power distribution via a connection cable 3AL
42732.
ALM
Alarm output connector of power unit.
5 Power unit
The power unit is used to :
interrupt the power supply (BAT1 and BAT2) either manually or automatically in case of
overcurrent.
provide an EMC filter on BAT1 and BAT2
protect the boards in this subrack from transients and surges on the battery power
supplies.
give urgent and non-urgent alarm signals.
The alarm contacts of the circuit breakers are combined and are available as urgent or
non-urgent alarm contacts to a common return.
Non-urgent alarm is given when one of both circuit breakers is switched off. Urgent
alarm is given when both circuit breakers are switched off.
The non-urgent alarm closes in a non-urgent alarm condition. The urgent alarm contact
opens in a urgent alarm condition.
Note The addresses can also be set by means of switches on the backpanel of the
subrack : however, this method can only be used on the following conditions :
the CNCC is mounted on the subrack;
there is no need to extend the Q1 bus to other subracks;
the other functionalities of the QEXA unit (access for synchronization clock
input or output, access for auxiliary alarm inputs) are not required.
If the address setting is realized by means of the switches on the QEXA unit, all
ATTENTION switches on the backpanel of the subrack have to be open.
Value Value
8 1 1 5
24 2 2 6
S302 0 3 3 7 S402
16 4 4 8
F X264
A
X266
Master Slave
E S678
S301 S401
D 1 1
2 2
3 3
4 4
5 5
GND 6 6
7 7
Open OUT IN 8 8
S246 ON S402ON
S7001 75Ω 120Ω 120 75Ω S302
S268 Ω
1 1
S286 S262 3
2 2
3
4 4 B
S285 ON ON
C S222 S524
S510
S221 64K 1200
Value Value
8 1 1 5
24 2 2 6
S302 0 3 3 7 S402
16 4 4 8
The addresses are assigned to the units on the subrack as follows :
the 1st address belongs to the PCM controller unit in position 4 (1st multiplexer) and
the main ringer power unit RGPA in position 9;
the 2nd address belongs to the PCM controller unit in position 5 (2nd multiplexer) and
the redundant ringer power unit RGPA in position 10, if provided;
the 3rd address belongs to the PCM controller unit in position 15 (3rd multiplexer);
the 4th address belongs to the ILTAUS unit is position 11 (option).
Value Value
8 1 1 5
24 2 2 6
S302 0 3 3 7 S402
16 4 4 8
Note Slave PCM controller units in other subrack positions can not be addressed.
Note Slave PCM controller units in other subrack positions can not be addressed.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
S701
1
2
3
4
S702 ON
If the address setting is realized on
1
2
3
the QEXA unit, these switches have 4
5
6
to be open (as shown) !! 7
8
ON