First order multiplexer subrack 3AL 42912

BAXX
not permitted without written authorization from Alcatel.
document, use and communication of its contents
All rights reserved. Passing on and copying of this

1 Function
This subrack has 17 positions for plug-in units and can be equipped with the necessary
units to build up to 3 complete first order multiplexer systems.

2 Front view

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

Test Test LMP Q2 PS ALM

3 Subrack equipment
The subrack is equipped as follows :

DOCC: *NA
MMCC: *NA
20031010

3AL 42912 BAAA TNAAA Edition 06 1 / 12


3AL 42912 First order multiplexer subrack
BAXX

not permitted without written authorization from Alcatel.


document, use and communication of its contents
All rights reserved. Passing on and copying of this
 1 (main) ringer/power unit in position 9;
 1 redundant ringer/power unit in position 10 (option);
 1 integrated line test unit ILTAUS in position 11 (option);
 1 CNCC unit in position 16 (option);
 1 Q1 extension unit QEXA in position 17 (option);
 the other positions can be equipped with the necessary units to build up to 3
multiplexer systems, as indicated below.
Multiplexer 1 is equipped in the positions 1 to 4 :
 1 (master) PCMC unit in position 4;
 the CSU's are mounted in the positions 1 to 3 :
 the CSU in position 1 is connected to the internal bus 2;
 the CSU's in position 2 and 3 are connected to the internal bus 1.
Multiplexer 2 is equipped in the positions 5 to 8 :
 1 (master) PCMC unit in position 5;
 the CSU's are mounted in the positions 6 to 8 :
 the CSU's in position 6 and 7 are connected to the internal bus 1;
 the CSU in position 8 is connected to the internal bus 2.
Multiplexer 3 is equipped in the positions 10 to 15 :
 1 (master) PCMC unit in position 15;
 the CSU's are mounted in the positions 10 to 14 :
 the CSU's in position 10 to 12 are connected to the internal bus 2;
 the CSU's in position 13 and 14 are connected to the internal bus 1.
Remarks :
 in case of channel drop and insert, a slave PCM controller unit can be mounted in the
positions 3, 6 and 14 for multiplexer 1, 2 and 3 respectively.
 the subrack is primarily intended to be used with channel units (CSU's) with 10 or 15
channels per unit (or occupying 10 or 15 time slots on the internal bus). However,
other channel units can be mounted as well. Channel units with different signalling
types can be combined in one subrack and in one multiplexer.
 when the channels on the CSU's occupy more than 30 time slots, at least one CSU
should be placed in such a position that the corresponding channels are connected to
bus 2. In this way the system configuration can be adapted, if required, by means of
man-machine commands only and without the need to rearrange the subrack layout.
 auxiliary units, if required, can be placed on any of the remaining places.
 In case 1511BA with clock protection a slave PCM controller unit can be mounted:
 in position 3 for multiplexer 1
 in position 6 for multiplexer 2
 in position 14 for multiplexer 3

2 / 12 3AL 42912 BAAA TNAAA Edition 06


First order multiplexer subrack 3AL 42912
BAXX
not permitted without written authorization from Alcatel.
document, use and communication of its contents
All rights reserved. Passing on and copying of this

4 Connectors on the backpanel of the subrack

Test
2 connectors for the through-connection between subracks of the test bus (daisy-chain
principle) :
01 : Not connected
06 : Not connected
02 : SL3 : Signal 3
07 : Not connected
03 : SL4 : Signal 4
08 : Not connected
04 : Not connected
09 : Not connected
05 : Not connected
Meaning :
 TPCM system : Signal 3 - 4 : not connected
 SPCM system :
 Signal 3 : TBA : test bus A-wire
 Signal 4 : TBB : test bus B-wire

LMP

06 : Not connected 01 : Not connected


07 : Not connected 02 : NUALLMP
08 : Not connected 03 : UALLMP
09 : Not connected 04 : EXTALLMP
05 : BATTF

This connector can be used with the cable 3AL 42877 AAAA to connect the lamps on top of
the rack.

3AL 42912 BAAA TNAAA Edition 06 3 / 12


3AL 42912 First order multiplexer subrack
BAXX

not permitted without written authorization from Alcatel.


document, use and communication of its contents
All rights reserved. Passing on and copying of this
Q2
Q2 interface connector (only if a CNCC is provided in position 16) :

08 : Not connected
15 : Not connected
07 : Not connected
14 : Not connected
06 : Clock in (+)
13 : Clock in (-)
05 : Not connected
12 : Electrical ground
04 : Data out (+)
11 : Data out (-)
03 : Not connected
10 : Electrical ground
02 : Data in (+)
09 : Data in (-)
01 : Safety ground

PS
Power supply connector, connected to the power distribution via a connection cable 3AL
42732.

ALM
Alarm output connector of power unit.

A1 : NURG : non-urgent alarm B1 : NURG non-urgent alarm


A2: CO : common return B2 : CO : common return
A3 : Not connected B3 : not connected
A4 : NURG: non-urgent alarm B4 : NURG : non-urgent alarm
A5 : CO : common return B5 : CO : common return

5 Power unit
The power unit is used to :
 interrupt the power supply (BAT1 and BAT2) either manually or automatically in case of
overcurrent.
 provide an EMC filter on BAT1 and BAT2
 protect the boards in this subrack from transients and surges on the battery power
supplies.
 give urgent and non-urgent alarm signals.
The alarm contacts of the circuit breakers are combined and are available as urgent or
non-urgent alarm contacts to a common return.
Non-urgent alarm is given when one of both circuit breakers is switched off. Urgent
alarm is given when both circuit breakers are switched off.
The non-urgent alarm closes in a non-urgent alarm condition. The urgent alarm contact
opens in a urgent alarm condition.

4 / 12 3AL 42912 BAAA TNAAA Edition 06


First order multiplexer subrack 3AL 42912
BAXX
not permitted without written authorization from Alcatel.
document, use and communication of its contents
All rights reserved. Passing on and copying of this

Specifications of the circuit breakers


The unit is equipped with circuit breakers on the BAT1 and BAT2 voltages with following
specifications :
 Current rating : 5 A
 Maximum resistance : 30 mΩ
 Nominal voltage rating : 72 VDC
 Short circuit breaking capacity : 1000 A at 72 VDC
 Isolation resistance : 100 MΩ at 500 VDC
 Dielectric strenght : 2kV AC

6 Setting of the system addresses


Up to 3 multiplexer systems can be mounted on this subrack. The Q1 bus addresses for
the systems on the subrack are set by means of switches on the QEXA unit in position 17.
For some general information, refer to section 3 of the manual : installation.

Note The addresses can also be set by means of switches on the backpanel of the
subrack : however, this method can only be used on the following conditions :
 the CNCC is mounted on the subrack;
 there is no need to extend the Q1 bus to other subracks;
 the other functionalities of the QEXA unit (access for synchronization clock
input or output, access for auxiliary alarm inputs) are not required.

If the address setting is realized by means of the switches on the QEXA unit, all
ATTENTION switches on the backpanel of the subrack have to be open.

7 System address setting by means of QEXA


The addressing is realized by means of the switches S301 and S302 (Enable A) and S401
and S402 (Enable B) on the QEXA unit (see figure 1).
This subrack enables different exploitation modes :
 in normal exploitation 1 PCM controller unit of each multiplexer system can be
addressed (the master);
 an alternative exploitation enables to address 2 PCM controller units of each
multiplexer system.

3AL 42912 BAAA TNAAA Edition 06 5 / 12


3AL 42912 First order multiplexer subrack
BAXX

not permitted without written authorization from Alcatel.


document, use and communication of its contents
All rights reserved. Passing on and copying of this
Normal exploitation
4 consecutive numbers (within the same group of 8) are assigned to the subrack. Selection
is achieved by setting 5 switches in the ON position :
 one switch of S301 is set to ON to select a group of 8 addresses (the other switches of
S301 and all switches of S302 are set to OFF);
 the first 4 switches of S401 are set to ON if the first 4 addresses of the group have to
be used (the other switches of S401 and all switches of S402 are set to OFF);
 the 4 switches of S402 are set to ON if the last 4 addresses of the group have to be
used (all switches of S401 are set to OFF).

6 / 12 3AL 42912 BAAA TNAAA Edition 06


First order multiplexer subrack 3AL 42912
BAXX
not permitted without written authorization from Alcatel.
document, use and communication of its contents
All rights reserved. Passing on and copying of this

Example : system addresses 17 to 20


 address 17 = 16 + 1 = position S301 : 3 and S401 : 1
 address 20 = 16 + 4 = position S301 : 3 and S401 : 4
Value Value
0 1 1 1
8 2 2 2
16 3 3 3
24 4 4 4
S301 32 5 5 5 S401
40 6 6 6
48 7 7 7
56 8 8 8

Value Value
8 1 1 5
24 2 2 6
S302 0 3 3 7 S402
16 4 4 8

3AL 42912 BAAA TNAAA Edition 06 7 / 12


3AL 42912 First order multiplexer subrack
BAXX

not permitted without written authorization from Alcatel.


document, use and communication of its contents
All rights reserved. Passing on and copying of this
CLK 123

F X264
A
X266

Master Slave

E S678

S301 S401
D 1 1
2 2
3 3
4 4
5 5
GND 6 6
7 7
Open OUT IN 8 8
S246 ON S402ON
S7001 75Ω 120Ω 120 75Ω S302
S268 Ω
1 1
S286 S262 3
2 2
3
4 4 B
S285 ON ON
C S222 S524
S510
S221 64K 1200

Figure 1 Position of the straps on the QEXA board

8 / 12 3AL 42912 BAAA TNAAA Edition 06


First order multiplexer subrack 3AL 42912
BAXX
not permitted without written authorization from Alcatel.
document, use and communication of its contents
All rights reserved. Passing on and copying of this

Example : system addresses 21 to 24


 address 21 = 16 + 5 = position S301 : 3 and S402 : 1
 address 24 = 16 + 8 = position S301 : 3 and S402 : 4
Value Value
0 1 1 1
8 2 2 2
16 3 3 3
24 4 4 4
S301 32 5 5 5 S401
40 6 6 6
48 7 7 7
56 8 8 8

Value Value
8 1 1 5
24 2 2 6
S302 0 3 3 7 S402
16 4 4 8
The addresses are assigned to the units on the subrack as follows :
 the 1st address belongs to the PCM controller unit in position 4 (1st multiplexer) and
the main ringer power unit RGPA in position 9;
 the 2nd address belongs to the PCM controller unit in position 5 (2nd multiplexer) and
the redundant ringer power unit RGPA in position 10, if provided;
 the 3rd address belongs to the PCM controller unit in position 15 (3rd multiplexer);
 the 4th address belongs to the ILTAUS unit is position 11 (option).

Extended addressing exploitation


8 consecutive numbers (i.e. 1 group of 8) are assigned to the subrack. Selection is
achieved by setting 9 switches in the ON position :
 one switch of S301 is set to ON to select a group of 8 addresses (the other switches of
S301 and all switches of S302 are set to OFF);
 all 8 switches of S401 are set to ON (all switches of S402 are set to OFF).
Example : system addresses 17 to 24
 address 17 = 16 + 1 = position S301 : 3 and S401 : 1
 address 24 = 16 + 8 = position S301 : 3 and S401 : 8
Value Value
0 1 1 1
8 2 2 2
16 3 3 3
24 4 4 4
S301 32 5 5 5 S401
40 6 6 6
48 7 7 7
56 8 8 8

Value Value
8 1 1 5
24 2 2 6
S302 0 3 3 7 S402
16 4 4 8

3AL 42912 BAAA TNAAA Edition 06 9 / 12


3AL 42912 First order multiplexer subrack
BAXX

not permitted without written authorization from Alcatel.


document, use and communication of its contents
All rights reserved. Passing on and copying of this
The addresses are assigned to the units on the subrack as follows :
 the 1st address belongs to the PCM controller unit in position 4 (1st multiplexer :
master) and the main ringer power unit RGPA in position 9;
 the 2nd address belongs to the PCM controller unit in position 5 (2nd multiplexer :
master) and the redundant ringer power unit RGPA in position 10, if provided;
 the 3rd address belongs to the PCM controller unit in position 15 (3rd multiplexer :
master);
 the 4th address belongs to the ILTAUS unit is position 11 (option);
 the 5th address belongs to the PCM controller unit in position 3 (1st multiplexer :
slave);
 the 6th address belongs to the PCM controller unit in position 6 (2nd multiplexer :
slave);
 the 7th address belongs to the PCM controller unit in position 14 (3rd multiplexer :
slave);
 the 8th address is not used.

Note Slave PCM controller units in other subrack positions can not be addressed.

8 System address setting by means of backpanel switches


The addressing is realized by means of the switches S702 (Enable A) an S701 (Enable B)
on the backpanel of the subrack (see figure 2).
By closing all switches on S701 and S702, the addresses 1 to 8 are assigned to the units of
the subrack in the following way :
 address 1 belongs to the PCM controller unit in position 4 (1st multiplexer : master)
and the main ringer power unit RGPA in position 9;
 address 2 belongs to the PCM controller unit in position 5 (2nd multiplexer : master)
and the redundant ringer power unit RGPA in position 10, if provided;
 address 3 belongs to the PCM controller unit in position 15 (3rd multiplexer : master);
 address 4 belongs to the ILTAUS unit is position 11 (option);
 address 5 belongs to the PCM controller unit in position 3 (1st multiplexer : slave);
 address 6 belongs to the PCM controller unit in position 6 (2nd multiplexer : slave);
 address 7 belongs to the PCM controller unit in position 14 (3rd multiplexer : slave);
 address 8 is not used.

Note Slave PCM controller units in other subrack positions can not be addressed.

10 / 12 3AL 42912 BAAA TNAAA Edition 06


First order multiplexer subrack 3AL 42912
BAXX
not permitted without written authorization from Alcatel.
document, use and communication of its contents
All rights reserved. Passing on and copying of this

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

Test Test LMP Q2 PS ALM

S701
1
2
3
4

S702 ON
If the address setting is realized on
1
2
3
the QEXA unit, these switches have 4
5
6
to be open (as shown) !! 7
8
ON

Figure 2 Position of the straps on the backpanel of the subrack

3AL 42912 BAAA TNAAA Edition 06 11 / 12


12 / 12
BAXX
3AL 42912
First order multiplexer subrack

3AL 42912 BAAA TNAAA


Edition 06
All rights reserved. Passing on and copying of this
document, use and communication of its contents
not permitted without written authorization from Alcatel.