First order multiplexer Desktop housing 3AL 42937

ABXX
not permitted without written authorization from Alcatel.
document, use and communication of its contents
All rights reserved. Passing on and copying of this

1 Function
The 9 position desktop housing was specifically designed to house 1 first order multiplexer.
Boards can be added to form a complete multiplexer as per desired specifications. An AC
power feed must be provided. A Digital Connection Frame (DCF) can be provided below
the plug-in unit mounting level for the connection of the station cables.

2 Front View
The desktop housing is depicted without its front cover. Switch S is located on the backpanel
of the housing.

DOCC: *NA
MMCC: *NA
20031010

3AL 42937 ABAA TNAAA Edition 02 1/6


2/6
ABXX
3AL 42937

1
2
3
4
5
6
7
8
9

S
First order multiplexer Desktop housing

3AL 42937 ABAA TNAAA


Edition 02
All rights reserved. Passing on and copying of this
document, use and communication of its contents
not permitted without written authorization from Alcatel.
First order multiplexer Desktop housing 3AL 42937
ABXX
not permitted without written authorization from Alcatel.
document, use and communication of its contents
All rights reserved. Passing on and copying of this

3 Subrack Equipment
2 basic configurations are possible on this housing, selectable by switch (see switch settings)
: with CNCC or without CNCC.

Network Controller CNCC equipped in the housing


 1 CNCC unit in position 9;
 1 master PCM controller unit in position 8;
 power supply units :
 if no ringing functions are required : 1 AC/DC converter with -48 V, +5 V and
-5 V supply (e.g. 3AL 42929) in positions 6 and 7;
 if ringing functions are required :
 1 AC/DC converter with -48 V supply (e.g. 3AL 42930) in positions 5 and 6;
 1 ringer/power unit in position 7;
 the positions 1 to 4 or 1 to 5 can be equipped with a redundant ringer/power board (if
applicable) and the necessary CSU's to build 1 multiplexer system :
 the CSU's in position 4 and 5 are connected to the internal bus 1;
 the CSU's in position 1 to 3 are connected to the internal bus 2.

Network Controller CNCC not equipped in the housing


 1 master PCM controller unit in position 8;
 power supply units :
 if no ringing functions are required : 1 AC/DC converter with -48 V, +5 V and
-5 V supply (e.g. 3AL 42929) in positions 6 and 7;
 if ringing functions are required :
 1 AC/DC converter with -48 V supply (e.g. 3AL 42930) in positions 6 and 7;
 1 ringer/power unit in position 9;
 the positions 1 to 5 can be equipped with a redundant ringer/power board (if
applicable) and the necessary CSU's to build 1 multiplexer system :
 the CSU's in position 4 and 5 are connected to the internal bus 1;
 the CSU's in position 1 to 3 are connected to the internal bus 2.
Remarks :
 in case of channel drop and insert, a slave PCM controller unit can be mounted in any
of the positions 1 to 5.

3AL 42937 ABAA TNAAA Edition 02 3/6


3AL 42937 First order multiplexer Desktop housing
ABXX

not permitted without written authorization from Alcatel.


document, use and communication of its contents
All rights reserved. Passing on and copying of this
 the housing is primarily intended to be used with channel units (CSU's) with 10 or 15
channels per unit (or occupying 10 or 15 time slots on the internal bus). However,
other channel units can be mounted as well. Channel units with different signalling
types can be combined in one housing.
 when the channels on the CSU's occupy more than 30 time slots, at least one CSU
should be placed in such a position that the corresponding channels are connected to
bus 2. In this way the system configuration can be adapted, if required, by means of
man-machine commands only and without the need to rearrange the layout.
 an integrated line test unit ILTAUS can be mounted in any of the positions 1 to 5.
 auxiliary units, if required, can be placed on any of the remaining places.
 In case 1511BA with clock protection the slave PCMC controller unit can only be
mounted in position 6.

Line terminal units


A line terminal unit can be mounted in any of the positions 1 to 5, not occupied by a
multiplexer unit.
The housing can also be equipped with line terminal units only :
 1 CNCC unit in position 9;
 1 AC/DC converter with -48 V supply (e.g. 3AL 42930) in positions 5 and 6;
 the other positions can be equipped with line terminal units.
Remark : in case of a 1+1 configuration, the corresponding units should be placed in
position 1 and 2, 3 and 4 or 7 and 8.

4 Switch settings on the backpanel


One switch is provided on the backpanel in position 9. This switch can only be reached if
no units are mounted on the housing.
The switch has to be set according to the equipped unit in position 9 : CNCC or
ringer/power.

4/6 3AL 42937 ABAA TNAAA Edition 02


First order multiplexer Desktop housing 3AL 42937
ABXX
not permitted without written authorization from Alcatel.
document, use and communication of its contents
All rights reserved. Passing on and copying of this

Switch in right position : ringer/power equipped in


position 9 (no CNCC equipped).

Switch in left position : CNCC equipped in position 9.

3AL 42937 ABAA TNAAA Edition 02 5/6


3AL 42937 First order multiplexer Desktop housing
ABXX

not permitted without written authorization from Alcatel.


document, use and communication of its contents
All rights reserved. Passing on and copying of this
5 System addresses
1 multiplexer system can be mounted on this housing. If a CNCC is mounted on the
housing, the Q1 bus addresses for the system on the housing are fixed in the backpanel
wiring. For some general information, refer to section 3 of the manual : installation.
The addresses are assigned to the units on the housing as follows :
 address 1 belongs to the PCM controller unit in position 8 and the ringer/power unit in
position 7 or 9, if provided;
 address 2 belongs to the redundant ringer/power unit in position 1 to 6, if provided,
and the AC/DC converter;
 address 3 belongs to the unit in position 1; *1
 address 4 belongs to the unit in position 2; *1
 address 5 belongs to the unit in position 3; *1
 address 6 belongs to the unit in position 4; *1
 address 7 belongs to the unit in position 5; *1
 address 8 belongs to the unit in position 6; *1
 address 9 belongs to the unit in position 7; *2
 address 10 belongs to the unit in position 8. *2

*1 This can be a slave PCM controller, ILTAUS or line terminal unit.


*2 This can be a line terminal unit if the housing is equipped with line terminal units only.

6/6 3AL 42937 ABAA TNAAA Edition 02