You are on page 1of 7

Channel and signalling E&M unit 3AL 43082

ADXX
not permitted without written authorization from Alcatel.
document, use and communication of its contents
All rights reserved. Passing on and copying of this

1 Function
This unit (Channel & Signalling Unit) forms the interface between the internal bus of a 2
Mbit/s multiplexer and 5 audio channels with 1E&1M signalling.

2 Information for system configuration


CTC version : CTC3
Internal bus channels :As the unit is provided with a programmable CTC, the position of
the unit on the subrack determines the unit address. The position of
the channel signals on the internal buses and hence the bus channel
numbers (from 1 to 15 and from 17 to 31) are determined by
means of man-machine commands :
 2 groups of bus channels are available for one CSU : 1 to 5 or
17 to 21;
 all channels on the same CSU must be connected to the same
group;
 the position of each channel in the group is fixed : channel N
on the CSU can thus be connected to bus channel N or (N+16);
 as soon as 1 channel on a CSU is allocated to a bus channel,
the group is fixed (all other channels must be allocated to the
same group);
 the number of channels that are used on each CSU is free :
unused bus channels can be allocated by other CSU's.

Signalling type options : refer to the first appendix document : equipment layout.
Correspondence between E- and M-wire status and signalling bits can be selected with
straps, see strap options

DOCC:
MMCC:
20021030

3AL 43082 ADAA TNAAA Edition 01 1/7


3AL 43082 Channel and signalling E&M unit
ADXX

not permitted without written authorization from Alcatel.


document, use and communication of its contents
All rights reserved. Passing on and copying of this
3 Operational data
Audio :
 2-wire or 4-wire operation : selectable, see strap options
 nominal impedance : 600 Ω
 input level 2-wire : -14 to +10 dBr
 input level 4-wire : -14 to +10 dBr
 output level 2-wire : -20 to +2.5 dBr
 output level 4-wire : -16 to +8 dBr
 adjustable in steps of 0,1 dB via man-machine commands, see section 3 of the
manual : installation
Signalling :
 E-wire inputs :
 earth detector sensitivity :
 should operate with 2 kΩ
 may not operate with 20 kΩ
 earth difference between exchange and CSU : max. +6 V
 M-wire outputs :
 current in M-wire to earth : max. 100 mA
 voltage drop of M-wire (connected to battery) : max. 0,05 V / mA

2/7 3AL 43082 ADAA TNAAA Edition 01


Channel and signalling E&M unit 3AL 43082
ADXX
not permitted without written authorization from Alcatel.
document, use and communication of its contents
All rights reserved. Passing on and copying of this

4 Front view

2x32-pin connector (D)


(detail see next page)

2x32-pin connector (C)


(detail see next page)

3AL 43082 ADAA TNAAA Edition 01 3/7


3AL 43082 Channel and signalling E&M unit
ADXX

not permitted without written authorization from Alcatel.


document, use and communication of its contents
All rights reserved. Passing on and copying of this
5 Front connectors
Front connector C : audio input and output signals

CA01 : A1MDF CB01 : B1MDF


CA02 : C1MDF CB02 : D1MDF
CA03 : A2MDF CB03 : B2MDF
CA04 : C2MDF CB04 : D2MDF
CA05 : A3MDF CB05 : B3MDF
CA06 : C3MDF CB06 : D3MDF
CA07 : A4MDF CB07 : B4MDF
CA08 : C4MDF CB08 : D4MDF
CA09 : A5MDF CB09 : B5MDF
CA10 : C5MDF CB10 : D5MDF
CA11 : Safety ground CB11 : Safety ground

Meaning : AiMDF : A-wire access of channel i


BiMDF : B-wire access of channel i
CiMDF : C-wire access of channel i
DiMDF : D-wire access of channel i
i is 1 to 5 for the 5 channels on one unit.
The channel signals are connected to the unit via multipair cables, terminated by means of
multipin plugs, as indicated on the figure above.
Cable code : 772 55066

4/7 3AL 43082 ADAA TNAAA Edition 01


Channel and signalling E&M unit 3AL 43082
ADXX
not permitted without written authorization from Alcatel.
document, use and communication of its contents
All rights reserved. Passing on and copying of this

Front connector D : signalling inputs and outputs

DA01 : E1MDF DB01 : M1MDF


DA02 : Safety ground DB02 : Safety ground
DA03 : E2MDF DB03 : M2MDF
DA04 : Safety ground DB04 : Safety ground
DA05 : E3MDF DB05 : M3MDF
DA06 : Safety ground DB06 : Safety ground
DA07 : E4MDF DB07 : M4MDF
DA08 : Safety ground DB08 : Safety ground
DA09 : E5MDF DB09 : M5MDF
DA10 : Safety ground DB10 : Safety ground
DA11 : Safety ground DB11 : Safety ground

Meaning :
 EiMDF : E-wire access of channel i
 MiMDF : M-wire access of channel i
 i is 1 to 5 for the 5 channels on one unit.

The channel signals are connected to the unit via multipair cables, terminated by means of
multipin plugs, as indicated on the figure above.
Cable code : 772 55129 XXXA

3AL 43082 ADAA TNAAA Edition 01 5/7


3AL 43082 Channel and signalling E&M unit
ADXX

not permitted without written authorization from Alcatel.


document, use and communication of its contents
All rights reserved. Passing on and copying of this
6 Strap options
For the location of the jumpers refer to figure 1.
For each channel on the unit a selection is possible between 4-wire and 2-wire operation
by means of the corresponding jumpers on Xi21 :
 jumpers in position 1-2 and 3-4 : 4-wire operation;
 jumpers in position 1-3 and 2-4 : 2-wire operation.
Remark : i is 1 to 5 for the channels 1 to 5 on the unit.
The correspondence between the E-wire status and the corresponding signalling bits can
be selected by means of the switch S81 :
 switch in position 2-3 : E-wires grounded make signalling bits 0;
 switch in position 1-2 : E-wires grounded make signalling bits 1.
The correspondence between the M-wire status and the corresponding signalling bits can
be selected by means of the switch S42 :
 switch in position 2-3 : signalling bits 0 make M-wires grounded
 switch in position 1-2 : signalling bits 1 make M-wires grounded
The TFC alarm can be enabled or disabled on the unit by means of the switch S1 :
 switch in position 2-3 : TFC alarm enabled;
 switch in position 1-2 : TFC alarm disabled.
The status of the M-wires during TFC alarm (if enabled, see above) and power-up can be
selected by means of the switch S58 :
 switch in position 2-3 : M-wires open during TFC alarm and power-up;
 switch in position 1-2 : M-wires grounded during TFC alarm and power-up.

6/7 3AL 43082 ADAA TNAAA Edition 01


Channel and signalling E&M unit 3AL 43082
ADXX
not permitted without written authorization from Alcatel.
document, use and communication of its contents
All rights reserved. Passing on and copying of this

1 2 3
S81
S1 A
3 2 1

2 1
X121
4 3

2 1 2 1
X321 X221
4 3 4 3
1 2 3
S58 2 1 2 1
S42 X521 X421
3 2 1 4 3 4 3

Figure 1 Position of the straps on the board

3AL 43082 ADAA TNAAA Edition 01 7/7