772 55211 First order multiplexer subrack
SXXA

not permitted without written authorization from Alcatel.


document, use and communication of its contents
All rights reserved. Passing on and copying of this
Subrack equipment
D 1 DC/DC converter in position 13;
D 1 PCM controller unit in position 12;
D the positions 1 to 11 can be equipped with channel and signalling units or auxiliary units.
Remarks :
Channel units (CSU's) with different signalling types can be combined in one subrack. Units in the positions 2
to 11 have access to bus 1, the unit in position 1 has access to bus 2. If the number of channels on the CSU's
is different and/or some CSU's have a programmable CTC and some have not, the position of the CSU's is
determined by some rules :
D for CSU's with a non-programmable CTC (CTC1 or CTC2) the position of the channel signals on the
internal buses is fixed : it is determined by the position of the CSU on the subrack. They should be
placed as indicated in the first part of the table on the next page :
- the CSU's with 5 channels are mounted, starting from the position with the lowest number, but
excluding position 1 (2, 3...). These units should never be placed in the positions 8 to 11.
- the CSU's with 3 channels are mounted, starting from the position with the highest number (11,
10...).
- the position of the channels on the internal bus 1 to the PCM controller is given in the second
part of the table on the next page. If CSU's with a different number of channels are mounted,
some time slots can be left unused or some time slots can be occupied by two different channel
types, depending upon the number of CSU's on the subrack. Remark that in the latter case one
of both channels has to be disabled, depending upon the local channel requirements (see strap
options on the CSU's).
D for CSU's with a programmable CTC (CTC3) the position of the channel signals on the internal buses
can be chosen freely and is determined by means of man-machine commands, refer to section 3 of
the manual : installation. They can be placed on any of the remaining places. The same applies for
units which are not provided with a CTC but with a control circuit offering the same possibilities.
D however for a CSU with programmable CTC and 15 channels, the channel selection on the internal
buses is limited to either the first or the last 15 channels of the bus. So, precautions have to be taken
that no other CSU's use either the first or the last 15 bus channels. For example the CSU's with
non-programmable CTC can be placed in the positions 2 to 6 (thus using the bus channels 1 to 15)
and the CSU with 15 channels in position 7 (thus using the bus channels 17 to 31).
When the channels on the CSU's occupy more than 30 time slots, one CSU should be placed in position 1 (so
these channels are connected to bus 2). In this way the system configuration can be adapted, if required, by
means of man-machine commands only and without the need to rearrange the subrack layout.
In case of channel drop and insert or digital channel distribution, up to 5 slave PCM controller units can be
mounted in the positions 2 to 11.
A second DC/DC converter can be mounted in one of the positions 1 to 11 (option).
Auxiliary units, if required, can be placed on any of the remaining places. Remark that the 1VF tone
generator occupies up to 5 time slots on the internal bus 1 or 2.

Note If the equipment is controlled by a CNCC, it has to be noted that a CNCC address can only be
assigned to position 12, refer also to strap fields and, for detailed information, to section 3 of the
manual (Installation). So, no slave PCM controller unit or APS unit should be mounted on the
subrack in case of CNCC control.

2/8   


  
     
  
 
not permitted without written authorization from Alcatel.
document, use and communication of its contents
All rights reserved. Passing on and copying of this

Note In case an LTR system (1510PL) is mounted on the multiplexer subrack :


G the LTR2M unit 772 51004 AXXA can only be equipped in position 2, 4, 6, 8 or 10;
G the LF2M unit 772 51020 AXXA (if required) has to be equipped in the position next right
to the LTR2M unit.

  
   /8
772 55211 First order multiplexer subrack
SXXA

not permitted without written authorization from Alcatel.


document, use and communication of its contents
All rights reserved. Passing on and copying of this
Time slot allocation for non-programmable CSU's
CSU Channel Number of channels per CSU
position type Time slot overlapping by channels on CSU is
not allowed *1 allowed *2
1 A 5 3
2 B 5 5 5 5 5 5 3 15 5 5 5 5 5 5 15
3 C 5 5 5 5 5 - 3 - 5 5 5 5 3 3 *4
4 D 5 5 5 5 - 3 3 - 5 5 5 5 3 3 *4
5 E 5 5 5 - - 3 3 *3 5 5 5 3 3 3 *4
6 F 5 5 - - 3 3 3 *3 5 5 3 3 3 3 *4
7 G 5 - - 3 3 3 3 *3 5 3 3 3 3 3 *4
8 H - - - 3 3 3 3 *3 5 3 3 3 3 3 *4
9 I - - 3 3 3 3 3 *3 3 3 3 3 3 3* *4
10 J - - 3 3 3
3 3 3 *3 3 3 3 3 3 3 *4
11 K - 3 3 3 3 3 3 *3 3 3 3 3 3 3 *4
Channel type on 1 B B B B B B B B B B B B B B B
time slots of 2 B B B B B B B B B B B B B B B
internal bus 1 3 B B B B B B B B B B B B B B B
4 B B B B B B C B B B B B B B/C B/*4
5 B B B B B B C B B B B B B B/C B/*4
6 C C C C C - C B C C C C C C B/*4
7 C C C C C D D B C C C C C/D D B/*4
8 C C C C C D D B C C C C C/D D B/*4
9 C C C C C D D B C C C C C/D D B/*4
10 C C C C C E E B C C C C/E C/E E B/*4
11 D D D D - E E B D D D D/E E E B/*4
12 D D D D - E E B D D D D/E E E B/*4
13 D D D D F F F B D D D/F D/F F F B/*4
14 D D D D F F F B D D D/F D/F F F B/*4
15 D D D D F F F B D D D/F D/F F F B/*4
16 - - - - - - - - - - - - - - -
17 E E E G G G G *3 E E/G E/G G G G *4
18 E E E G G G G *3 E E/G E/G G G G *4
19 E E E G G G G *3 E/H E/G E/G G G G *4
20 E E E H H H H *3 E/H E/H E/H H H H *4
21 E E E H H H H *3 E/H E/H E/H H H H *4
22 F F - H H H H *3 F/H F/H H H H H *4
23 F F I I I I I *3 F/I F/I I I I I *4
24 F F I I I I I *3 F/I F/I I I I I *4
25 F F I I I I I *3 F/I F/I I I I I *4
26 F F J J J J J *3 F/J F/J J J J J *4
27 G - J J J J J *3 G/J J J J J J *4
28 G - J J J J J *3 G/J J J J J J *4
29 G K K K K K K *3 G/K K K K K K *4
30 G K K K K K K *3 G/K K K K K K *4
31 G K K K K K K *3 G/K K K K K K *4
Channel type on 1 A A
time slots of 2 A A
internal bus 2 3 A A
4 A -
5 A -
6-31 - -

4/8   


  
     
  
 
not permitted without written authorization from Alcatel.
document, use and communication of its contents
All rights reserved. Passing on and copying of this

*1 : in case of CSU's with CTC1


*2 : only in case at least one of the overlapping CSU's has a CTC2 or CTC3, see remark on previous page
*3 : as in column 3, 4, 5 and 6
*4 : as in the previous columns

   



    

PS
Power supply connector, connected to the distribution cable 772 55102 AXAA via a connection cable
772 55103 AAAA if the distribution cable is provided or connected to a battery connection block via
connection cable 772 55103 ABAA if the distribution cable is not provided.
If the subrack is equipped in a module with distribution cable, the subrack power is connected as shown
below :
Power bus
772 55102 AXAA
to distribution panel
*1
+5V -5V

PS CS AL MTL1 MTL2 CL
Black Yellow-green
Black Brown
Red Blue

Piercing terminal
(code 770 14600 AFUA)
Cable 772 55103 AAAA
from Subrack
to power bus *1 See backpanel connector +5V

If the subrack is equipped in a module without distribution cable, the subrack power is connected as shown
below :

+5V -5V

PS CS AL MTL1 MTL2 CL

Station battery 1 negative pole Black Yellow-green


Safety ground
Station battery 2 negative pole Black Brown Not connected
Station battery common positive pole Red Blue Not connected

Cable 772 55103 ABAA


to Subrack
and battery connection block

  
   /8
       

 

not permitted without written authorization from Alcatel.


document, use and communication of its contents
All rights reserved. Passing on and copying of this
CS
Central supervisory connector, connected to the supervisory distribution flatcable if a CASU or CNCC is
provided on the module.

+5V
+5 V connector, connected on only one first order multiplexer subrack to the power distribution cable
772 55102 AXAA for the +5 V supply to the alarm subrack, if an alarm subrack is used and if there is no
DC/DC converter on the alarm subrack.

-5V
-5 V connector.

AL
Alarm bus output connector for remote alarm supervision system. The signals on this connector depend on
the PCMC variant :
D PCMC : 772 52102 BBBA / 3AL 43018 BXXX
The open collector alarm output is active (low impedance with respect to ARTN=ground) in case of
alarm on the system.

B01 : UA : Urgent Alarm A01 : NUA : Non-Urgent Alarm


B02 : ARTN : Alarm ReTurN A02 : PA : Power Alarm
B03 : Electrical ground A03 : Electrical ground
B04 : UA : Urgent Alarm A04 : NUA : Non-Urgent Alarm
B05 : ARTN : Alarm ReTurN A05 : PA : Power Alarm

D PCMC : 772 52102 BABA


The alarm signals TFC and NUA are provided by relay contacts, which are active (connected to ARTN)
in case of alarm on the system. The PA alarm signal is an open collector signal, which presents a low
impedance with respect to ARTN in case of alarm on the system.

B01 : TFC : Transm. failure A01 : NUA : Non-Urgent Alarm


B02 : ARTN : Alarm ReTurN A02 : PA : Power Alarm
B03 : Electrical ground A03 : Electrical ground
B04 : TFC : Transm. failure A04 : NUA : Non-Urgent Alarm
B05 : ARTN : Alarm ReTurN A05 : PA : Power Alarm

/8   


  
     
  
 
not permitted without written authorization from Alcatel.
document, use and communication of its contents
All rights reserved. Passing on and copying of this

MTL1
Multiple connector 1 (through-connection between subracks) : this connector can be used as follows :
D used for the connection of a +48 V supply for some signalling units if provided;
D if the optional TEST-E unit 772 52126 AAAA is equipped on one subrack of the module, see section 4
of the manual (operation), it is used for the through-connection of the test bus :

B01 : SL3 : Signal 3 A01 : SL4 : Signal 4


B02 : SL5 : Signal 5 A02 : SL2 : Signal 2
B03 : Electrical ground A03 : Electrical ground
B04 : SL3 : Signal 3 A04 : SL4 : Signal 4
B05 : SL5 : Signal 5 A05 : SL2 : Signal 2

Meaning :
D TPCM system :
 Signal 2 : +48V : positive battery supply for some CSUs (if provided) via cable 772 55149
 Signal 3 - 4 - 5 : not connected
D SPCM system :
 exchange :
- Signal 2 : not connected
- Signal 3 : TBA : test bus A-wire
- Signal 4 : TBB : test bus B-wire
- Signal 5 : TBF : test bus free indication wire
 subscriber :
- Signal 2 : not connected
- Signal 3 : TBA : test bus A-wire
- Signal 4 : TBB : test bus B-wire
- Signal 5 : ALARM : ringing generator alarm

  
   /8
772 55211 First order multiplexer subrack
SXXA

not permitted without written authorization from Alcatel.


document, use and communication of its contents
All rights reserved. Passing on and copying of this
MTL2
Multiple connector 2 (through-connection between subracks) : can be used for the ringing bus (normally
not used).

B01 : SL6 : Signal 6 A01 : Not connected


B02 : SL0 : Signal 0 A02 : SL1 : Signal 1
B03 : Electrical ground A03 : Electrical ground
B04 : SL6 : Signal 6 A04 : Not connected
B05 : SL0 : Signal 0 A05 : SL1 : Signal 1

Meaning :
D TPCM system : Signal 0 - 1 - 6 : not connected
D SPCM system :
- exchange : Signal 0 - 1 - 6 : not connected
- subscriber :
- Signal 0 : RBR : ring bus ring lead
- Signal 1 : RBT : ring bus tip lead
- Signal 6 : not connected

CL
Clock signal connector :

B01 : C2OT A01 : C2OF


B02 : ECLKIT A02 : ECLKIF
B03 : Electrical ground A03 : Electrical ground
B04 : ECLKIT A04 : ECLKIF
B05 : C2OT A05 : C2OF

Meaning :
D C2OT-C2OF : system clock output
D ECLKIT-ECLKIF : external synchronization clock input
By means of straps on the PCM controller unit both the output and the input can be matched to 120 Ω
balanced or 75 Ω unbalanced. In the latter case the A-pins or the B-pins can be grounded (refer to the
strap options on the PCM controller unit).

Strap field : (above flatcable connector) :


Used only if a CASU or CNCC is provided.
The system numbers for the central alarm system are assigned according to the installation description
(section 3 of the manual), depending upon the position of the subrack on the module.

8/8   


  