1 Function
This subrack has 17 positions for plug-in units and can be equipped with the necessary
units to build up to 3 complete first order multiplexer systems.
2 Front view
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
DOCC: *NA
MMCC: *NA
20031010
Test
2 connectors for the through-connection between subracks of the test bus (daisy-chain
principle) :
01 : Not connected
06 : Not connected
02 : SL3 : Signal 3
07 : Not connected
03 : SL4 : Signal 4
08 : Not connected
04 : Not connected
09 : Not connected
05 : Not connected
Meaning :
TPCM system : Signal 3 - 4 : not connected
SPCM system :
Signal 3 : TBA : test bus A-wire
Signal 4 : TBB : test bus B-wire
LMP
This connector can be used with the cable 3AL 42877 AAAA to connect the lamps on top of
the rack.
08 : Not connected
15 : Not connected
07 : Not connected
14 : Not connected
06 : Clock in (+)
13 : Clock in (-)
05 : Not connected
12 : Electrical ground
04 : Data out (+)
11 : Data out (-)
03 : Not connected
10 : Electrical ground
02 : Data in (+)
09 : Data in (-)
01 : Safety ground
BAT
Power connection to battery
CONTR
Control connector
05 : Not connected
09 : Not connected
04 : Not connected
08 : Not connected
03 : SHUNT +
07 : Not connected
02 : SHUNT -
06 : Not connected
01 : Not connected
ALARM
For connection to End of Discharge (EOD) unit (switch between battery charging and
subrack fed by battery).
01 : EODAL
06 : EODRES +
02 : FUSEAL
07 : EODRES -
03 : Not connected
08 : Not connected
04 : COMMON
09 : Not connected
05 : Not connected
Note After connecting the battery to the subrack, the subrack has to be reset by
looping 'EODRES+' to 'EODRES -'in order to activate the battery feed.
CLK 123
F X264
A
X266
Master Slave
E S678
S301 S401
D 1 1
2 2
3 3
4 4
5 5
GND 6 6
7 7
Open OUT IN 8 8
S246 ON S402ON
S7001 75Ω 120Ω 120 75Ω S302
S268 Ω
1 1
S286 S262 3
2 2
3
4 4 B
S285 ON ON
C S222 S524
S510
S221 64K 1200
Note The addresses can also be set by means of switches on the backpanel of the
subrack : however, this method can only be used on the following conditions :
the CNCC is mounted on the subrack;
there is no need to extend the Q1 bus to other subracks;
the other functionalities of the QEXA unit (access for synchronization clock
input or output, access for auxiliary alarm inputs) are not required.
If the address setting is realized by means of the switches on the QEXA unit, all
ATTENTION switches on the backpanel of the subrack have to be open.
Normal exploitation
4 consecutive numbers (within the same group of 8) are assigned to the subrack. Selection
is achieved by setting 5 switches in the ON position :
one switch of S301 is set to ON to select a group of 8 addresses (the other switches of
S301 and all switches of S302 are set to OFF);
the first 4 switches of S401 are set to ON if the first 4 addresses of the group have to
be used (the other switches of S401 and all switches of S402 are set to OFF);
the 4 switches of S402 are set to ON if the last 4 addresses of the group have to be
used (all switches of S401 are set to OFF).
Value Value
0 1 1 1
8 2 2 2
16 3 3 3
24 4 4 4
S301 32 5 5 5 S401
40 6 6 6
48 7 7 7
56 8 8 8
Value Value
8 1 1 5
24 2 2 6
S302 0 3 3 7 S402
16 4 4 8
Value Value
0 1 1 1
8 2 2 2
16 3 3 3
24 4 4 4
S301 32 5 5 5 S401
40 6 6 6
48 7 7 7
56 8 8 8
Value Value
8 1 1 5
24 2 2 6
S302 0 3 3 7 S402
16 4 4 8
Value Value
0 1 1 1
8 2 2 2
16 3 3 3
24 4 4 4
S301 32 5 5 5 S401
40 6 6 6
48 7 7 7
56 8 8 8
Value Value
8 1 1 5
24 2 2 6
S302 0 3 3 7 S402
16 4 4 8
The addresses are assigned to the units on the subrack as follows :
the 1st address belongs to the PCM controller unit in position 4 (1st multiplexer :
master) and the main ringer power unit RGPA in position 9;
the 2nd address belongs to the PCM controller unit in position 5 (2nd multiplexer :
master) and the redundant ringer power unit RGPA in position 10, if provided;
the 3rd address belongs to the PCM controller unit in position 15 (3rd multiplexer :
master);
the 4th address belongs to the ILTAUS unit is position 11 (option);
the 5th address belongs to the PCM controller unit in position 3 (1st multiplexer :
slave);
the 6th address belongs to the PCM controller unit in position 6 (2nd multiplexer :
slave);
the 7th address belongs to the PCM controller unit in position 14 (3rd multiplexer :
slave);
the 8th address is not used.
Note Slave PCM controller units in other subrack positions can not be addressed.
Note Slave PCM controller units in other subrack positions can not be addressed.
S701
1
2
3
4
S702 ON
If the address setting is realized on
1
2
3
the QEXA unit, these switches have 4
5
6
to be open (as shown) !! 7
8
ON