Grid Recurrence Blackout: Legend
Grid Recurrence Blackout: Legend
Blackout
Grid recurrence
Here we can see a blackout duration 10s, 200 rpm and 200Nm torque. As we can see the
Legend:
speed (red) turns from 200rpm into the opposite direction 180rpm for a moment and then
CH1_Speed[U/min] => speed actual value from external encoder the motor decelerates the speed up to 100rpm therefore we reduce the back flow of the oil.
nact[rpm] => speed actual value from calculation
CON_ACT_VDC[V] => dc-link voltage actual value
The current (purple) is nearly always at the same value. He is adjusted at the switching
MON_CurrentRMS[A]=> current(rms) actual value
points to the right level.
Blackout
Grid recurrence
The same behavior is also here. Blackout for 10s with 200rpm and 400Nm.
Blackout
Grid recurrence
Here we have a blackout for lower than 10s, 200rpm and 600Nm.