You are on page 1of 1

POOTH KHURD VILLAGE BAWANA INDUSTRIAL AREA - I STATION BAWANA IND II

CL
1 2 3 5 6
80000
20000 20000 20000 20000

D C A B
302 302 301 301

ST-4 PLT. TO FOB (MM) ST-3 PLT. TO FOB (MM)


TREAD 300 TREAD 300
RISER 150 RISER 150
WIDTH 1200 (CLEAR) WIDTH 2400 (CLEAR)
1200x800 SPACE
1200x800 SPACE
FOR TRACTION 2500 FOR TRACTION
1200x800 SPACE
20 PAX LIFT 1200x800 SPACE
FOR TELE/ E&M 79 69 59 49 FOR TELE/ E&M

2600
(SIZE AS PER VENDOR)

2600
DN TO FOB

1400
49 59 69 79 ST-3 LOBBY LIFT-1
ST-4 DN TO FOB 1200x800 SPACE
+230.520M WICKET GATE
FOR SIGNALING
A WICKET GATE
5000x1750 SPACE
3400 1520 2435 2435 1520 3400

FOR SIGNALING OPEN


PLATFORM A PLATFORM A
PLATFORM
+230.520M +230.520M
7355

ROOF
ABOVE
14710

B
RAIL LEVEL
ROOF +229.430M
ABOVE
7355

OPEN PLATFORM B PLATFORM B


1 5000x1750 SPACE PLATFORM +230.520M +230.520M 1
303 303
FOR SIGNALING
C WICKET GATE
WICKET GATE

1400
49 59 69 79
ST-5 1200x800 SPACE

2600
DN TO FOB ST-2
DN TO FOB FOR SIGNALING
79 69 59 49
1200x800 SPACE
FOR TELE/ E&M

ST-5 PLT. TO FOB (MM) ST-2 PLT. TO FOB (MM) 1200x800 SPACE
CORRIDOR BELOW TREAD 300 TREAD 300 FOR TRACTION
RISER 150 RISER 150
WIDTH 1200 (CLEAR) WIDTH 2400 (CLEAR) LOBBY 2500 PLUMBING SHAFT
D5 FD3 FUTURE ESCALATOR GROUND TO FOB
+230.520M 1000X1000
1200x800 SPACE CAT LADDER

2600
FOR TELE/ E&M TERRACE LIFT-2
+230.470M ELECTRICAL PANEL
1200x800 SPACE 1150X400
FOR TRACTION
SERVICE SHAFT 1
2500 X 1680 MM

20 PAX LIFT
LEGEND (SIZE AS PER VENDOR)
200 MM ACC BLOCK WORK

RCC WALL
D C A B
PARAPET/ TOE WALL/BOUNDARY WALL 302 302 301 301

FILLED FLOORING

X
SEC./ELEV.NAME
00000
DRAWING NUMBER PLATFORM LEVEL PLAN
1 SCALE
EARTHMAT : 1/200

NOTES-

1. ALL DIMENSIONS ARE IN MM, UNLESS OTHERWISE MENTIONED.


2. ALL DIMENSIONS ARE TO BE READ AND NOT MEASURED.
3. GROUND LEVELS ARE INDICATIVE, CONTRACTOR TO VERIFY EXISTING LEVELS AT SITE PRIOR TO COMMENCEMENT OF
CONSTRUCTION.
4. CONTRACTOR TO VERIFY THE LEVELS FOR STAIRCASE AND LIFT/ESCALATORS PRIOR TO COMMENCEMENT OF
CONSTRUCTION.
5. ALL LEVELS ARE IN METERS, INDICATING T.O.C. (TOP OF CONCRETE) WHEREVER APPLICABLE.
6. ABSOLUTE RAIL LEVEL SHALL BE TAKEN FROM DMRC ALIGNMENT DRAWING.
7. ALL MINIMUM INTERNAL CLEARANCES ARE MANDATORY AND SHALL BE PROVIDED.
8. THIS DRAWING MUST BE READ IN CONJUNCTION WITH ALL RELEVANT ARCHITECTURAL, STRUCTURAL, PLUMBING, FIRE TYPICAL DRAWING REFERENCE NO:-
FIGHTING, ELECTRICAL AND TRAFFIC MANAGEMENT DRAWINGS. 1). EIRA1DE005-DMRC-FDS-AR-DC03-TYP-40004 - PLATFORM LEVEL FLOORING PLAN
9. ANY DISCREPANCIES MUST BE BROUGHT TO NOTICE OF THE ENGINEER BEFORE EXECUTION OF WORK AT SITE.
10. ALL DOOR'S/WINDOW'S SILL & LINTEL LEVELS ARE FROM MAIN FLOOR FINISH LEVEL. 2). EIRA1DE005-DMRC-FDS-AR-DC03-TYP-40005 - FLOORING DETAIL
11. COLUMN LOCATION AND STRUCTURAL ARRANGEMENT SHOWN ARE INDICATIVE ONLY. 3). EIRA1DE005-DMRC-FDS-AR-DC03-TYP-40006 - FLOORING DETAIL
12. ALL CUTOUTS AND FIRST FIX PROVISIONS FOR MEP/SYSTEMS REQUIREMENTS TO BE REFERRED FROM LATEST REVISION DOORS STR. OPENING (IN MM)
OF DISCIPLINE DRAWINGS. 4). EIRA1DE005-DMRC-FDS-AR-DC03-TYP-40011 - ENTRY/EXIT DETAIL
13. ROOM SIZES/MASONRY WORK AT THE STATION MAY VARY AS PER DETAILED ARCHITECTURAL LAYOUT OF THE STATION. S.NO. TYPE WIDTH SILL LINTEL LVL REVISION NOTE - R1
FROM FFL 5). EIRA1DE005-DMRC-FDS-AR-DC03-TYP-40012 - ENTRY/EXIT DETAIL
14. FOR LIGHTING ARRANGEMENT & ELECTRICAL DETAILS, PLEASE REFER SPECIFIC ELECTRICAL DRAWINGS.
13 D1
D5 750
1000 150 2100 1. Electrical Panel provided
15. EARTH MAT SIZE AND LOCATION TO BE GOT CONFIRMED FROM E&M (DMRC).
16. VENDOR SPECIFIC DRAWINGS FOR PIT SIZE AND STRUCTURAL ARRANGEMENT FOR LIFT / ESCALATOR,AS FINALIZED BY SHAFT SCHEDULE
FD - FIRE RATED DOORS STR. OPENING 2. Separate electrical & plumbing shaft provided
DMRC, TO BE REFERRED.
17. ALL THE WORK ARE IN LUMPSUM SCOPE UNLESS OTHERWISE MENTIONED
(IN MM) ROOM NO. TYPES OF ROOM LENGTH x WIDTH (M) AREA (SQ.M) FIRST DESIGN SUBMISSION- FINISHES
S.NO. TYPE WIDTH SILL LINTEL LVL 3. Staircase 3 & 4 from platform to fob added
18. ALL THE COMPONENTS LIKE RAMPS,DROP OF ETC COMPLETE FOR MMI INTEGRATION UTTIPEC S 01 SHAFT 1 2.3 X 2.8 6.44
FROM FFL This drawing must not be loaned, copied or otherwise reproduced in whole or in part or used for
GUIDELINES & APPLICABLE CODES TO BE CONSIDERED UNDER RELEVANT 3 FD1
FD3 750 150 2100 S 02 SHAFT 2 2.3 X 2.8 6.44 4. 5000x1750mm space for signalling provided
BOQ OR DMRC AGREEMENT. any purpose without the prior written permission of DMRC.
CLIENT: DELHI METRO RAIL CORPORATION LTD. PROJECT: Certified that this document has been designed and checked in accordance with DDC Quality
Contract DC03- : Part Design and Construction of Elevated
APPROVAL BY DMRC OFFICIALS Assurance Plan.
NORTH DELHI METRO PROJECT - PHASE -4
Metro Bhawan
Fire Brigade Lane, Barakhamba Road, Viaduct from Rithala to Narela 14 Elevated Stations and 5

ARCHITECTURE
DESIGNATION NAME/ SIGNATURE DESIGNATION NAME/ SIGNATURE
New Delhi - 110001,India At-Grade Stations viz. Rithala Interchange, Rohini Sector 25, RITHLA-BAWANA-NARELA
Board No. - 23417910/12 26, 31, 32, 36, Barwala, Pooth Khurd, Bawana Ind-I, Bawana AM/MGR ARCH DY CA CA PM CPM APPROVED BY DESIGNED BY
Ind-II, Bawana, Bawana JJ Colony, Sanoth, New Sanoth, STATION:
Fax No. - 23417921
Depot Station, Bhorgarh, Anaj Mandi, Narela DDA Sports
PROJECT SENIOR BAWANA INDUSTRIAL AREA - I STATION
DY CEE/ E&M CEE/ E&M DY CE/ TRACK CE/ TRACK DIRECTOR V. RAJENDRAN ARCHITECT R.SHARMA
Complex and Narela (including Entry & Exit structures at
CONSULTANT: stations but excluding Architectural finishing, Pre-engineered CHECKED BY DRAWN BY TITLE : PLATFORM LEVEL PLAN
R1 REVISED AS PER DMRC COMMENTS A.KUMAR R.SHARMA A. SAINI 03/08/2021
egis rail steel roof structure and roof sheeting of stations) from
Chainage 0.0 M to 23449.287 M of Rithala - Bawana-Narela
DY CSTE/ TELE CSTE DGM/ DESIGN GM/ TECH
A.CHIEF
ARCHITECT A. SAINI ARCHITECT
A.KUMAR DRG NO: REVISION NO. : SCALE : SIZE : STATUS:
Corridor of Delhi Metrolite Phase-IV project" R0 FIRST ISSUE A.KUMAR R.SHARMA A. SAINI 28/04/2021
egis india DY CSTE/ SIG GM / IT DY CEE/TRACTION GM / TRACTION
MEPF
EXPERT
DATE
03/08/2021 EIRA1DE005-DMRC-FDS-AR-DC03- IA1-09213 R1 A1 FIRST DESIGN
DY CSTE/AFC DY CEE / L&E CEE/ PLANING AM/ CIVIL REV. PARTICULARS DRN. DGN. CHD. DATE A.KUMAR