You are on page 1of 5

1 2 3 4 5 6 7 8 9 10 11 12

00. LINE TYPES LEGEND 02. PIPELINE FITTINGS CONT. 03. VALVES CONT. 05. SELF ACTUATED 07. PUMPS 11. INSTRUMENT AND CONTROLS 12. SCREENING
OPEN VENT
REGULATORS AND VALVES
MAIN PROCESS LINE CYLINDER VALVE
(GIVE NOTE IF RUN TO GRADE) PUMP, GENERAL SYMBOL FO
X
SECONDARY PROCESS LINE GENERAL SYMBOL (UNSPECIFIED) INCLINED SCREEN (MECH RAKED)
OPEN DRAIN
PCV
PINCH VALVE
A INSULATED / LAGGED XXXX FE A
PROCESS LINE IN-LINE PRESSURE RELIEF XX
OVERFLOW (EG. TANK) OR SAFETY VALVE
PROCESS LINE DOUBLE PUMP, CENTRIFUGAL
SHOWING PRESSURE SETTING
CONTAINED
SYPHON DRAIN AIR PURGING DEVICE PITOT TUBE OR ANNUBAR
FLEXIBLE HOSE LINE
PCV FE INCLINED SCREEN (MOTOR
OPEN OR COVERED CONCRETE NON-RETURN / CHECK VALVE / XXXX PRESSURE RELIEF XX RAKED)
TUNDISH / DRAIN PUMP, RECIPROCATING
CHANNEL REFLUX VALVE OR SAFETY VALVE
INSTRUMENT SUPPLY OR SHOWING PRESSURE SETTING
VORTEX METER
CONNECTION TO PROCESS STRAINER, GENERAL SYMBOL DOUBLE NON-RETURN CHECK
VALVE FE
UNDEFINED SIGNAL
PRV XX
BURSTING DISC PUMP, HELICAL ROTOR
XXXX
PNEUMATIC SIGNAL PRESSURE REGULATING
IN-LINE PRESSURE MAGNETIC FLOWMETER ROTARY FINE SCREEN
B M B
SPECTACLE BLIND, RELIEF VALVE
ELECTRICAL SIGNAL
NORMALLY CLOSED FQI
ELECTRICAL BINARY SIGNAL - XX
\ \ \ \ \ PRESSURE VACUUM VALVE PUMP, ROTARY VANE
DIGITAL SPECTACLE BLIND, POSITIVE DISPLACEMENT TYPE
ELECTROMAGNETIC OR SONIC NORMALLY OPEN PRV FLOWMETER C/W FLOW
SIGNAL XXXX TOTALIZING INDICATOR
SPADE BLIND (OR SLIP BLIND) CIRCULAR GUIDE VANE VALVE PUMP CONTROL
CAPILLARY TUBING BAND SCREEN
PUMP, DOSING
SPACER
FI VARIABLE AREA FLOW
HYDRAULIC SIGNAL
PRelV XX INDICATOR
GAS RELIEF VALVE
XXXX BACK PRESSURE REGULATING
SPRAY HEADER OR DIFFUSER
01. LABELLING PERISTALTIC PUMP FE
ROTARY VALVE
XX
SPRAY NOZZLE
C TURBINE OR PROPELLER METER
C
PRV BASKET STRAINER
LINE 1 PROCESS FLOW CONTINUATION XXXX
LINE 2 FLAG - 3 LINES RUPTURE DISK (OR BURSTING CONE VALVE PRESSURE REGULATING
AAXYZ-PPPP IN LEFT / OUT RIGHT PSE (EXTERNAL TAPPING)
DISC) SUBMERSIBLE PUMP
XXXX FE
PRESSURE RELIEF
XX
8301PU EQUIPMENT NUMBER DISPLAY
FLUME
PRelV
BAR SCREEN
PSE RUPTURE DISK (OR BURSTING XXXX
DIRECTION OF FLOW / ARROW
XXXX DISC) BACK PRESSURE REGULATING 08. MOTORS AND DRIVES FE
VACUUM RELIEF (EXTERNAL TAPPING) XX
CONNECTION (OF LINES) 04. ACTUATORS
ULTRASONIC FLOWMETER
MECHANICAL VIBRATOR
PROCESS LINE CROSSOVER 06. ACTUATOR FAIL POSITIONS M MOTOR

03. VALVES AUTOMATIC ACTUATOR


PVCU DICL PIPE SPECIFICATION
D CHANGE POINT DIAPHRAGM SEAL D
TWO WAY VALVE, FAIL CLOSED
AUTOMATIC ACTUATOR WITH
TURBINE 13. BLOWERS AND COMPRESSORS
VALVE SIZE INDICATED ABOVE
TP POSITIONER
TERMINATION POINT VALVE (GENERAL SYMBOL)
TAG No. INDICATED BELOW TWO WAY VALVE, FAIL OPEN I I TO P CONVERTER
P FAN
GATE VALVE MINI HYDRO
PISTON ACTUATOR
A B THREE WAY VALVE, FAIL OPEN
BALL VALVE TO PATH A-C I BLOWER
INTERLOCK OR LOGIC FUNCTION
LOC LIMIT OF CONTRACT
PISTON ACTUATOR WITH C 09. FLOW CONTROL DEVICES
GLOBE VALVE POSITIONER
A P G
PIPING GENERATOR
PIPE TO INSTRUMENTATION NEEDLE VALVE B PURGE OR FLUSHING DEVICE
INST. FOUR WAY VALVE, FAIL OPEN
SPECIFICATION CHANGE POINT DIAPHRAGM ACTUATOR V-NOTCH WEIR
C TO PATHS A-C & D-B
REDUCING VALVE D ATTENUATOR / SILENCER
E S E
IPXX-X INTERFACE POINT
AUTOMATIC DIAPHRAGM SELECTOR SWITCH
RECTANGULAR WEIR
ABOVE GROUND & ACTUATOR
DIAPHRAGM VALVE AIR DRYER
a/g u/g UNDERGROUND BURIED ANY VALVE, FAIL LOCKED
R
RESET OR LATCH TYPE
REDUCED PRESSURE ZONE PNEUMATIC DIAPHRAGM DRYER
STOPLOG OR BOARD ACTUATOR
DEVICE ACTUATOR
ANY VALVE, FAIL INTERMEDIATE
02. PIPELINE FITTINGS
PRESSURE BALANCED SCREEN CONTROL SWITCH AND/OR AFTER COOLER
AAxBB PENSTOCK
DIAPHRAGM ACTUATOR PUSHBUTTON STATION
REDUCER THE FAILURE MODES INDICATED ARE THOSE COMMONLY
DEFINED BY THE TERM "SHELF POSITION". LUBRICATOR
BUTTERFLY VALVE VENTURI
SPRING ACTUATOR - FOR
HOSE CONNECTION FEMALE PRESSURE RELIEF OR SAFETY
AS AN ALTERNATIVE TO THE ARROWS AND BARS, THE FLOAT SWITCH
VALVE ONLY F FILTER
FOLLOWING ABBREVIATIONS MAY BE EMPLOYED: FO
HOSE CONNECTION MALE PLUG VALVE
F XX F
FLOW ELEMENT, ORIFICE TYPE D/F
HANDWHEEL DISPOSABLE FILTER
END CAP ANGLE VALVE FO - FAIL OPEN AIR SUPPLY FITTING
WALL TYPE
W/F
BLANKED FLANGE WASHABLE FILTER
ANGLE FLOAT VALVE SOLENOID FC - FAIL CLOSED BELLMOUTH
AIR EXHAUST FITTING
FLANGED JOINT WALL TYPE AIR FILTER

PLUGGED SOCKET IN-LINE FLOAT VALVE WEIGHT FL - FAIL LOCKED (LAST POSITION)
10. MIXING AND FLOCCULATION
AIR SUPPLY FITTING
HOSE COUPLING CEILING TYPE COMPRESSOR
KNIFE GATE VALVE FI - FAIL INTERMEDIATE
FLOAT SUBMERSIBLE MIXER
BELLOWS OR EXPANSION JOINT
AIR EXHAUST FITTING
AGITATOR, FAN, PROPELLER CEILING TYPE DAMPER, SINGLE BLADE
FLANGED VALVE SLIDE GATE VALVE LO - LOCKED OPEN
G M MOTORISED G
EDUCTOR/INJECTOR/EJECTOR
TRAP LC - LOCKED CLOSED FLASHING LIGHT OR SIGNAL DAMPER, MULTI BLADE
THREE WAY VALVE LAMP OPPOSED
P PNEUMATIC ACTUATOR AXIAL FLOW MIXER OR
WATER TRAP
FLOCCULATOR
NO - NORMALLY OPEN
DAMPER, MULTI BLADE
STATIC IN-LINE MIXER ULTRASONIC LEVEL PROBE
H PARALLEL
STRAINER, Y-TYPE (FLANGED) HYDRAULIC ACTUATOR
FOUR WAY VALVE
NC - NORMALLY CLOSED

LEVEL SWITCH PADDLE DAMPER, FIRE


TRAPPED VENT G GEARBOX F
M AERATOR
B

DRAWING STATUS
DAM RES SPS
STANDARD DRAWING Current
H BWS WAT STP
PIPING AND INSTRUMENTATION DIAGRAM (P&ID) H

A INITIAL ISSUE 15/06/2018 C. Dickson K. Danenbergsons D. Eager


WTP

WPS
SEW

REC
DRAWING SYMBOLS
SHEET 1 OF 2
SD-1100-D
ISSUE

No. ISSUE DATE DRAWN CHECKED AUTHORISED ASSET AREA APPLICABILITY A1 © Icon Water. 2017
A
1 2 3 4 5 6 7 8 9 10 11 12
Date Plotted: 25/06/2018 Plot Style: Water.ctb Plotted by: Essery, Scott CADD File Name:C:\Temp\BC-WorkSpace\S_ESSERY\M-Seappsprd37,D-DrwWaterdbP\Masters\Standard_Drawing\1100\SD_1100_D.dwg
1 2 3 4 5 6 7 8 9 10 11 12

14. FILTRATION 16. SLUDGE TREATMENT 18. CHLORINATION AND 20. GRIT AND OIL REMOVAL 21. EQUIPMENT (MISC.) CONT. 22. STORAGE AND PRESSURE 23. WATER AND SEWAGE
DECHLORINATION VESSELS CONT. COMBINED FLUID CODES
FIXED HOIST (HAND OPERATED)
MECHANICAL CLASSIFIER
A SAND FILTER (SHEET MEDIA)
FILTER PLATE PRESS 1. REFER TO STD-SPE-M-002 FOR THE A
EVAPORATOR APPLICATION OF WATER AND SEWAGE
ACCUMULATOR OR TREATMENT FLUID CODES AS WELL AS VALVE
TRAVELING HOIST PULSATION DAMPENER AND PIPING IDENTIFICATION CODES.
FILTER BELT PRESS 2. REFER TO WORK INSTRUCTION WI05.14.04
RAPID GRAVITY SAND FILTER TITLED "ENGINEERING ASSET
CHLORINATOR INCLUDING GRIT CLASSIFIER (SCREW TYPE)
Cl₂ INJECTOR IDENTIFICATION" FOR THE APPLICATION OF
OVERHEAD CRANE
ASSET LABELING AND EQUIPMENT
CENTRIFUGE (HORIZONTAL) IDENTIFICATION CODES.
PRESSURE VESSEL
MEMBRANE FILTER MODULE
ELECTRICAL PLUG AND SOCKET
B GAS CYLINDER B

15. SEDIMENTATION TANKS, CENTRIFUGE (BOWL TYPE) 21. EQUIPMENT (MISC.) SPRING

THICKENERS AND CLARIFIERS 24. INSTRUMENTATION & CONTROL


ELECTROLYSER
ELECTROLYSER
NORMALLY
INSECT SCREENED VENT PRIMARY
22. STORAGE AND PRESSURE FIELD LOCATION
LOCATION
NORMALLY
NOT
ACCESSIBLE
VAC MOUNTED NORMALLY
CIRCULAR THICKENER 17. SOLIDS HANDLING VACUUM REGULATOR
VESSELS SCRUBBER WITH DEMIST PAD
ACCESSIBLE
ACCESSIBLE
TO
TO
OPERATOR
FLAT BOTTOM TO
OPERATOR (BEHIND
FIRE EXTINGUISHER OPERATOR
THE PANEL)

GAS DRUM DISCRETE X X X X


C C
INSTRUMENTS X X X X
CIRCULAR THICKENER CYCLONE SEPARATOR SKIP BIN
CONICAL BOTTOM
UV LAMP
STORAGE TANK COMPUTER X X X X
FUNCTION X X X X
ODOUR ABSORPTION TOWER
FIRE HOSE REEL
WITH DEMIST PAD AND MEDIA
RECTANGULAR
CONVEYOR (BELT TYPE)
19. HEAT TRANSFER EQUIPMENT OR BIOTRICKLING FILTER SHARED
THICKENER/SEDIMENTATION DISPLAY X X X X
TANK SHARED X X X X
HEAT EXCHANGER
HOSE COCK CONTROL
INCLINED CONVEYOR (BELT
TYPE) PROGRAMMABLE
X X X X
RECTANGULAR ELECTRIC HEATER OPEN TANK LOGIC CONTROL
(PLC) X X X X
GRIT SEPARATION TANK HYDRANT

D FIRE HYDRANT D
CONVEYOR (SCREW TYPE)
ADSORPTION COLUMN OR
OIL BURNER TOWER
CLARIFIER WITH SCREW DOWN HYDRANT
PERIPHERAL LAUNDER
OPEN TANK WITH COVER
INCLINED CONVEYOR (SCREW
TYPE)
GAS BURNER
DELUGE SHOWER

CLARIFIER WITH RADIAL CONVEYOR (BUCKET TYPE) HEATER


LAUNDER
EYE WASH SEALED TANK
HORIZONTAL TANK
E E
FLAME ARRESTOR

SAFETY SHOWER & EYE WASH


SCUM DRAW OFF WEIGHING MACHINE

WEIGHBRIDGE OR PLATFORM BOILER SILO (BASIC SYMBOL) CONTACT TANK


CARBOY/CONTAINER
WEIGHER
RAKE SCRAPER

CALIBRATION CYLINDER
COLLECTOR / HOPPER
SURFACE SKIMMER FURNACE
INSPECTION HATCH /
F MAINTENANCE HATCH F

SLUDGE ROLLER DISINTEGRATOR/MACERATOR SIGHT LEVEL INDICATOR


ACCUMULATOR
BOTTLE/PULSATION
AIR COOLED CONDENSER DAMPENER

FLIGHT SCRAPER SIGHT LEVEL INDICATOR WITH


GAUGE
DOUBLE PIPE HEAT EXCHANGER

SCRAPER (GENERAL)

PLATE HEAT EXCHANGER WHEELY BIN


G G

SCRAPER (CHAIN & FLIGHT)


FIN TUBE HEAT EXCHANGER
AUTOMATIC SAMPLER

LAGOON WATER SURFACE LEVEL


VAPOURISER

HORN

DRAWING STATUS
DAM RES SPS
STANDARD DRAWING Current
H BWS WAT STP
PIPING AND INSTRUMENTATION DIAGRAM (P&ID) H

A INITIAL ISSUE 15/06/2018 C. Dickson K. Danenbergsons D. Eager


WTP

WPS
SEW

REC
DRAWING SYMBOLS
SHEET 2 OF 2
SD-1101-D
ISSUE

No. ISSUE DATE DRAWN CHECKED AUTHORISED ASSET AREA APPLICABILITY A1 © Icon Water. 2017
A
1 2 3 4 5 6 7 8 9 10 11 12
Date Plotted: 25/06/2018 Plot Style: Water.ctb Plotted by: Essery, Scott CADD File Name:C:\Temp\BC-WorkSpace\S_ESSERY\M-Seappsprd37,D-DrwWaterdbP\Masters\Standard_Drawing\1100\SD_1101_D.dwg
1 2 3 4 5 6 7 8 9 10 11 12

VALVES OTHER FITTINGS

WATER SEWER WATER SEWER WATER SEWER


A A
AV
GATE VALVE X X AIR VALVE - SINGLE X X AIR GAP DEVICE DEAD END

DAV

ALT
ALTITUDE X AIR VALVE - DOUBLE X X AIR VESSEL DISCHARGE POINT

EAV

BAV
BACKUP ALTITUDE X AIR VALVE - ENHANCED DOUBLE X X BLANK FLANGE GAUGING POINT (ACTIVE)
FUNCTIONALITY

KNIFE X X BALL VALVE X X DISMANTLING JOINT GAUGING POINT (NON-ACTIVE)


B B

*
M

MOTORISED X X SMS INSPECTION SHAFT (STANDARD


ZONE VALVE X END CAP
225mm)
M
MOTORISED - NORMALLY DCV
CLOSED X X DOUBLE CHECK VALVE X FLOW ELEMENT MAINTENANCE HOLE

NORMALLY CLOSED X X FLOAT OPERATED VALVE X FLOW METER OR RECORDING DEVICE REDUCER

BUTTERFLY VALVE X RP
NEEDLE VALVE X GIBAULT JOINT RODDING POINT
C C
ALTITUDE X P M S
ALT PENSTOCK VALVE X X HYDRANT - MILCOCK SCREEN

BAV
BACKUP ALTITUDE X PLUG P SIS
PLUG VALVE X HYDRANT - PILLAR SPECIAL INSPECTION SHAFT
DUAL FLOW RATE
FRCV CONTROL X STORAGE TANK (BURIED) OR
PRESSURE RELIEF VALVE X HYDRANT - SPRING
SEWAGE OVERFLOW STRUCTURE
FLOW RATE ALTITUDE
X
FUNCTIONALITY

FAV COMBINATION SL OH
D
STOP LOG X OVERHEAD FILLING POINT STORAGE TANK (NOT BURIED)
D
FRCV
FLOW RATE CONTROL X SVE
STOP OR SCOUR VALVE (NORMALLY
X X INLINE VALVE - TONGUE REMOVED VENT (EDUCT)
M SCOUR CLOSED ON SCOUR OR DRAIN PIPE)
MOTORISED X
SVI
M
MOTORISED - NORMALLY
X
* TEMPORARY ZONE VALVE X MAINTENANCE HOLE VENT (INDUCT)

CLOSED
ORIFICE PLATE VERTICAL DROP
SVD
NORMALLY CLOSED X
E
SERVICE CONNECTION FITTINGS PRESSURE GAUGE OR RECORDING
DEVICE
V
VORTEX DROP
E
PCV
PUMP CONTROL X
REDUCED PRESSURE ZONE DEVICE W
WEIR
(RPZD)
GLOBE VALVE X WATER
REDUCER / TAPER VERTICAL RISER
ALT
ALTITUDE X BILLING METER SMALL(<40mm)

PUMP, PUMP STATION TEE


BAV
BACKUP ALTITUDE X BILLING METER LARGE(≥40mm)

FLOW RATE ALTITUDE SP SAMPLING POINT


F F
FAV COMBINATION X MAIN COCK
FUNCTIONALITY

TEE / OPEN END


FRCV
FLOW RATE CONTROL X STOPCOCK

THRUST BLOCK
OCV
OUTLET CONTROL X
SEWER TRENCH / SCOUR
PRV
PRESSURE REDUCING X
BVR
BURIED VERTICAL RISER (BVR) NOTES:
G PSV
PRESSURE SUSTAINING X G

1. ALL SYMBOLS SHALL BE SHOWN IN BLACK UNLESS PRESENTED OTHERWISE.


SERVICE POINT
PCV PUMP CONTROL X
2. REFER TO DRAWING SD-1103 FOR LINETYPES.
SLOPE JUNCTION
CONE VALVE X 3. SYMBOLS SIZED FOR LEGIBILITY WHEN PRINTED AT A3 SIZE.

4. VALVE AND FITTINGS NORMALLY OPEN UNLESS NOTED OTHERWISE.


FUNCT.
ALT
ALTITUDE X

DRAWING STATUS
DAM RES SPS
STANDARD DRAWING Current
H BWS WAT STP
BULK WATER, WATER & SEWERAGE H
A

B
INITIAL ISSUE

DISTRICT METER ZONE VALVE CHANGED TO ZONE VALVE


15/06/2018

18/06/2019
S. Essery

S. Essery
K. Danenbergsons

K. Danenbergsons
D. Eager

C. Patrick
WTP

WPS
SEW

REC
DESIGN SYMBOLS FOR PLANS AND TIE BOOKS SD-1102-D
ISSUE

No. ISSUE DATE DRAWN CHECKED AUTHORISED ASSET AREA APPLICABILITY A1 © Icon Water. 2017
B
1 2 3 4 5 6 7 8 9 10 11 12
Date Plotted: 2/07/2019 Plot Style: Water.ctb Plotted by: Essery, Scott CADD File Name:C:\Temp\BC-WorkSpace\S_ESSERY\M-Seappsprd37,D-DrwWaterdbP\Projects\CX10999\Standard_Drawing\1100\SD_1102_D.dwg
1 2 3 4 5 6 7 8 9 10 11 12

TABLE 1: LINETYPES FOR THE PRODUCTION OF KEY PLANS, HYDRAULIC PLANS AND SERVICE PLANS
TABLE 3: LINETYPES FOR THE PRODUCTION OF DRAINAGE PLANS & TIE BOOKS
A A
LINE TYPE SERVICE TYPE LINE COLOUR LINE THICKNESS (mm)
eW WATER MAIN/LINE (REF. NOTE 1) 7 0.25 LINETYPE SERVICE TYPE LINE COLOUR LINE THICKNESS (mm)
eS GRAVITY SEWER MAIN
W DOMESTIC WATER SERVICE 3 0.50
EXISTING ASSETS - SRM SEWER RISING MAIN
HYDRAULIC PLANS FS FIRE SERVICE
WATER OR SEWER SEWER SCOUR MAIN, SEWER TIE OR
eS
PROPERTY SERVICE LINE SS SPRINKLER SERVICE
eS MAIN/LINE TO BE DECOMMISSIONED - S S 14 0.50
SEWER OR WATER (REF. NOTE 2) SEWER MAIN, MANHOLE AND JUNCTION
B B
W W 35 0.70 SW STORMWATER MAIN, MANHOLE AND 84
BULK WATER MAIN TIE BOOKS
SUMP (REF. NOTE 3)
W W WATER DISTRIBUTION MAIN 175 174
W WATER MAIN
W W
WATER RETICULATION MAIN 145

WATER RISING MAIN 145


TABLE 4: LINETYPES FOR THE PRODUCTION OF KEY PLANS, HYDRAULIC PLANS & SERVICE PLANS -
WATER NETWORK - DRAIN LINE 235 OTHER UTILITIES (NOTE 3)
PROPOSED OR NEW
ASSETS - WATER WATER NETWORK - OVERFLOW LINE 75
NETWORK
WATER NETWORK - SCOUR LINE
45 LINETYPE SERVICE TYPE LINE COLOUR LINE THICKNESS (mm)
C C
215
WATER NETWORK - WASHDOWN LINE ERM EFFLUENT REUSE MAIN (EFF) 3 0.50
WATER NETWORK - DOMESTIC SERVICE 135 0.70
ELECTRICITY (ELC)
LINE
235 G GAS MAIN (GAS)
WATER NETWORK - FIRE SERVICE LINE
EXISTING ASSETS 0.50
S 245 0.70 SW STORMWATER MAIN (STW)
SEWER GRAVITY MAIN - RETIC
TELECOMMUNICATIONS (e.g. TELSTRA)
S 245
SEWER GRAVITY MAIN - TRUNK
X X ABANDONED
D S 245 D
SEWER GRAVITY MAIN - TUNNEL 4 0.70
ERM EFFLUENT REUSE MAIN (EFF)
145
SEWER SYPHON MAIN ELECTRICITY (ELC)
PROPOSED OR NEW 245
SRM SEWER RISING MAIN G GAS MAIN (GAS)
ASSETS - SEWERAGE PROPOSED OR NEW
NETWORK ASSETS TELECOMMUNICATIONS (e.g. TELSTRA)
65
SEWER SCOUR MAIN
X X ABANDONED
SEWER NETWORK - TIE OR 232 0.25
PROPERTY SERVICE LINE SW STORMWATER MAIN (STW) 85
232
SEWER TIE (CONNECTED TO MAINS)
E E
BVR
SEWER TIE (WITH BVR CONNECTED TO 232 NOTES:
MAINS)
252 1.50 1. WATER MAINS/LINES ARE DEFINED AS: BULK SUPPLY MAINS, DISTRIBUTION MAINS, RETICULATION MAINS, RISING MAINS, DRAIN LINES,
STAGE BOUNDARY OVERFLOW LINES, SCOUR LINES, WASHDOWN LINES, DOMESTIC SERVICE LINES AND FIRE SERVICE LINES, ALL OF WHICH HAVE THE
OTHER INTENDED PURPOSE OF CONVEYING BULK OR POTABLE WATER.
206 1.00
WATER ZONE BOUNDARY
2. A MAIN/LINE TO BE DECOMMISSIONED, WHETHER IT BE FOR WATER OR SEWERAGE, SHALL BE ANNOTATED TO SHOW THE TYPE OF
DECOMMISSIONING. FOR EXAMPLE, DESCRIPTORS SUCH AS "ABANDONED" , "EXHUMED" , "DECOMMISSIONED AND END CAPPED" SHALL BE
CLEARLY SHOWN ON THE RELEVANT PLANS. THIS WILL ALLOW ICON WATER TO BETTER DETERMINE WHETHER A DECOMMISSIONED LINE
TABLE 2: HYDRAULIC INFORMATION BOXES
CAN BE REINSTATED FOR USE AT A LATER DATE.
F SEWER MAIN SEWER TIE STORMWATER (REF. NOTE 3) F
612.220 UPSTREAM INVERT LEVEL
3. UTILITIES NOT OWNED/OPERATED BY ICON WATER SHALL BE SHOWN IN ACCORDANCE WITH THE RELEVANT AGENCY/UTILITY'S DRAFTING
612.220 UPSTREAM INVERT LEVEL
150 PE PIPE DIAMETER & MATERIAL
SEWER 675 x PIPE DIAMETER / MATERIAL STANDARDS ON THE CONDITION THAT EXISTING AND NEW/PROPOSED LINES ARE SHOWN IN COLOUR "0" (BLACK) WITH THE EXCEPTION
28.3 m PIPE LENGTH (m) T 1.0 TIE LENGTH (m)
28.3 m PIPE LENGTH (m) OF STORMWATER. ICON WATER AND TRANSPORT CANBERRA AND COMMUNITY SERVICES (TCCS) HAVE AGREED THAT STORMWATER LINES
D 0.0 TIE DEPTH (m)
0.46 % PIPE GRADE S 100 TIE SIZE (mm) 0.46 % PIPE GRADE
612.090 DOWNSTREAM INVERT LEVEL
M uPVC
TIE MATERIAL
(BOTH EXISTING AND PROPOSED) SHALL BE SHOWN IN ACCORDANCE WITH TCCS DRAFTING REQUIREMENTS (i.e. BLACK FOR EXISTING AND
612.090 DOWNSTREAM INVERT LEVEL
GREEN FOR NEW/PROPOSED). IF THE RELEVANT AGENCY/UTILITY DOES NOT HAVE A DEFINED DRAFTING STANDARD THEN THE ICON
WATER PREFERRED LINETYPES SHOWN IN TABLE 4 SHALL BE APPLIED.

4. REFER TO DRAWING SD-1102 FOR THE DESIGN SYMBOLS TO BE USED.

PIPE MATERIALS LINE THICKNESS 5. THE LINE COLOURS INDICATED IN TABLES 1 TO 4 ABOVE REFER TO COLOUR NUMBERS FROM THE STANDARD AUTOCAD COLOUR PALETTE.
THE LINEWEIGHTS INDICATED ARE FOR PRINTING AT A1 SIZE. WHEN PRINTING AT A3 SIZE, HALFWIDTHS SHALL BE USED.
G PIPE SPECIFICATION CHANGE POINT 0.25mm G

L OF C LIMIT OF CONTRACT

L OF C

DRAWING STATUS
DAM RES SPS
STANDARD DRAWING Current
H BWS WAT STP
BULK WATER, WATER & SEWERAGE H
A

B
INITIAL ISSUE

SEWER TIE INFORMATION BOX AND LINE TYPES UPDATED


15/06/2018

18/06/2019
M. Matusiak

S. Essery
K. Danenbergsons

K. Danenbergsons
D. Eager

C. Patrick
WTP

WPS
SEW

REC
LINETYPES AND NOTATION
FOR PLANS AND TIE BOOKS
SD-1103-D
ISSUE

No. ISSUE DATE DRAWN CHECKED AUTHORISED ASSET AREA APPLICABILITY A1 © Icon Water. 2017
B
1 2 3 4 5 6 7 8 9 10 11 12
Date Plotted: 2/07/2019 Plot Style: Water.ctb Plotted by: Essery, Scott CADD File Name:C:\Temp\BC-WorkSpace\S_ESSERY\M-Seappsprd37,D-DrwWaterdbP\Projects\CX10999\Standard_Drawing\1100\SD_1103_D.dwg
1 2 3 4 5 6 7 8 9 10 11 12

NOTES:
LEGEND WITH ALL
RELEVANT LINE TYPES 1. ARRANGEMENTS AND DETAILS OF SERVICES,
A AND SYMBOLS SHOWN THRUST RESTRAINTS AND EQUIPMENT DEPICTED IN A
THIS DRAWING ARE EXAMPLES ONLY. THIS
DRAWING IS NOT TO BE USED AS A GUIDE TO
1 2 3 4 5 6 560 7 8 9 10 11 12 WATER AND SEWER PIPE AND EQUIPMENT
LAYOUTS.
2. A HYDRAULIC CONNECTIONS DRAWING MUST
52
CONTAIN THE FOLLOWING DETAILS:

eS
LEGEND

150∅ DICL
eS
A A
EXISTING WATER MAIN
· A PLAN VIEW OF THE FULL EXTENT OF THE
PRESSURE ZONE BOUNDARY EXISTING SEWER MAIN
W ZONE VALVE. REFER DETAIL 3 CONNECTION AREA.

W
NEW WATER MAIN
· ALL ADJOINING (INCLUDING FUTURE) STAGES /
NEW WATER PROPERTY SERVICE LINE DISCONNECT AND REMOVE END CAP AND ICON WATER ASSETS TO THE CONNECTION AREA.
FROM CONNIE RESERVOIR STAGE CONNECTION THRUST BLOCK. CONNECT NEW 150∅
B SEE DETAIL 1
STAGE BOUNDARY
WATER MAIN. CONNECTION BY ICON · LOCATION OF ALL ZONE VALVES, PRV'S, HYDRANTS B
PRESSURE ZONE BOUNDARY WATER AT CONTRACTORS EXPENSE AND SLUICE VALVES.
W 3
· PRESSURE ZONES, WITH CLEAR BOUNDARIES AND

eS
NEW SEWER MAIN / PROPERTY SERVICE LINE
LABELS STATING PRESSURE DETAILS.

150∅ DICL
B eW B
(NEW) (EXISTING)
· ALL CONNECTION DETAILS, WITH REFERENCE TO

W
79 77 eW WATER STOP VALVE
83 81
8 11
0 THE RELEVANT CONNECTION DETAIL AND

P A R K W A Y

D A N E N B E R G S O N S
6 10
10
4 10 75 WATER FIRE HYDRANT
4

W 4
1 2 3
5 DRAWING NUMBER (IF APPLICABLE).
2 3 WATER REDUCER
1 · LEGEND WITH ALL RELEVANT LINE TYPES AND
35
eS * * ZONE VALVE DETAIL 1 SYMBOLS.
51
8 7 6
SEWER MAINTENANCE HOLE
PRESSURE ZONE 11 10 9
STAGE CONNECTION DETAIL
5 11 SEWER VERTICAL DROP 3. DETAILS OF ALL CONNECTION POINTS ARE TO BE

D A N E N B E R G S O N S
7 6
9 8 7 9 SVD SVD
5
INFORMATION 10
2
1 3
SHOWN ON THE HYDRAULIC CONNECTIONS PLAN. IF

W
6 4 eW
C SHOWN C 12 10 8
C ADDITIONAL SPACE IS REQUIRED, A DEDICATED C
eS
eW

150∅ DICL
NABIN ROAD
SVD
S T R E E T eS CONNECTION DETAILS DRAWING IS TO BE
M A T T H E W 12 14 16

P A R K W A Y
10
2 4 6 8 PROVIDED AS THE NEXT DRAWING IN THE SET.
SUPER HIGH 8

eW
SVD
5 3 1 7
7 5 6
11 9 2 3 4
1
PRESSURE ZONE 4 5 6 7 REMOVE BLANK FLANGE

W
2 3
1 34 BY ICON WATER AT
98
TWL 685.0 CONTRACTORS EXPENSE.

W
50 13 12
16 15 14
18 17
19
8 15
11 10 9
11 13
13 12 7 9
14 1 3 5
D 15 2 D
14 12 10 8 6 4 eS CONNECTION DETAILS
16 E
McRAE PLAC (NOTE 3)
eW

H
SVD
eS 150∅ DICL
H

14 16
W

*
S T R E E T 12
eS

D HIGH PRESSURE E S S E R Y 8 10
D
*

2 4 6

eW

eW
SVD 3 1 8
5 7
ZONE SVD
11 9 7 5 6
T

13 3 4
17 15 2
1 150 x 150 TEE
N

10
PRESSURE ZONE
E

9
TWL 640.0 8

STAGE 1B
6 7
C

4 5

STAGE 1D
92 2 3 33
S

BOUNDARIES 1
DETAIL 2
E
R

SHOWN
C

49 16
STAGE CONNECTION 20 19 18 17
STAGE CONNECTION DETAIL
A

21
eS

24 23 22
SEE DETAIL 1
T

E 11 E
S

13 12 13 15 17
15 14 11
LI

16 5 7 9
18 17 3
20 19 1
A

21
6 4 2 eS
C

14 12 10 8 eS
20 18 16 PAUL PAR
22 eW
eW
S
SVD SUPER HIGH PRESURE ZONE HIGH PRESURE ZONE
PAUL PARADE
eW
FL-FL PIPE SPACER
D 1 2 HYDRANT AND TEE
SV 1 2

STAGE 1A
D
76

STAGE 1C
eS D SV
D SV
1
2
FL-FL SPOOL PIPE ZONE VALVE, CLOSED
SV
2 16
1 15 eS
E 2 16 FL-SOC E

*
15

SVD
1
86 3 4 FL-FL PIPE THRUST WALL
3 73 74 15
CONNECT TO EXISTING 14 16
31
1
SPACER
3 13
eS

13 14 16
SEWER MAINTENANCE HOLE 3
F 84 16
71 72 14
4 6 F
4
11 12 15
4
12 15
eW

82 15
4 11
70
5 8
H
eW

13
5 69 32 9
9 10 14
FL-SOC STOP VALVE, OPEN
eW

CONNECTION 5 9
10 14
5
46 6 10
80 14 68 12
LOCATIONS SHOWN AND 47 67
THRUST WALL
6
eS

48
eS

eW
8 13
eS

7 12
eS

6 7
REFERENCED ON PLANS
eS

8 13
7 66 11
eS

6
78 13
7 65
6 12 16 DETAIL 3
7 5 8
6 12 64 10
7 5 8
eW

76 12 14 30
PRESSURE ZONE BOUNDARY ZONE VALVE
G BAILEY'S RESIDENTIAL ESTATE 0 40 80 120 160 200m
G
F STAGE 1 - SUB STAGE 1A SCALE 1:2000 F
SEWER AND WATER KEY PLAN
SCALE 1:2000 @ A1

Drawn:
Issued For Construction
Scale: Date: Sheet No.:
I. McDonell KEIRAN 30/01/2018
Designed: Project No.: Tender No.:
C. Allen BAILEY'S RESIDENTIAL ESTATE CX10999
H A INITIAL ISSUE 26/06/2019 STAGE 1D ACT Cadastral information supplied by the ACT Environment H
& Sustainable Development Directorate. © ACT Gov. 2016.
No. REVISION DATE ENG CHECKED VERIFIED DESIGN AUTH HYDRAULIC CONNECTIONS
Rev
PLAN 2019/00112
1 2 3 4 5 6 7 8 9 10 11 12 TITLE BLOCK TO BE PREPARED IN
G Water.ctb ACCORDANCE WITH ICON WATER G
DRAFTING STANDARDS

ALL INFORMATION SHOWN ON


STAGE LABEL SCALE BAR TO BE SHOWN
THIS DRAWING MUST BE CLEAR
WHEN PRINTED AT A3

DRAWING STATUS
DAM RES SPS
STANDARD DRAWING Current
H BWS WAT STP
WATER AND SEWER NETWORK H

A INITIAL ISSUE 26/06/2019 S. Essery K. Danenbergsons C. Patrick


WTP

WPS
SEW

REC
HYDRAULIC CONNECTIONS DRAWING
DRAWING EXAMPLE AND REQUIREMENTS
SD-1104-C
ISSUE

No. ISSUE DATE DRAWN CHECKED AUTHORISED ASSET AREA APPLICABILITY A1 © Icon Water. 2017
A
1 2 3 4 5 6 7 8 9 10 11 12
Date Plotted: 3/07/2019 Plot Style: Water.ctb Plotted by: Essery, Scott CADD File Name:C:\Temp\BC-WorkSpace\S_ESSERY\M-Seappsprd37,D-DrwWaterdbP\Projects\CX10999\Standard_Drawing\1100\SD_1104_C.dwg

You might also like