FLOW SHEET AND PIPING SYMBOLS VALVE SYMBOLS

PSE
MAIN PROCESS LINE FLANGED CONNECTION 001
DIAPHRAGM VALVE ANGLE VALVE
W/ BLIND FLANGE

PRODUCT UTILITY LINE CLAMP TYPE RUPTURE DISK (PRESSURE)


GATE VALVE ANGLE BALL VALVE
SANITARY FITTING
HV
SCREWED OR SOCKET WELDED 001 AUTOMATIC ON/OFF VALVE PISTON
GENERAL UTILITY LINE GLOBE VALVE OPERATED
PIPE CAP KNIFE/SLIDE VALVE
FO FO = FAIL OPEN
HOSE OR FLEXIBLE TUBING HOSE COUPLING BALL VALVE FLUSH BOTTOM FL = FAIL LAST
DIAPHRAGM VALVE _V (BLANK) = FAIL CLOSED
HOSE COUPLING - SINGLE END RADIAL DIAPHRAGM VALVE 001
DOUBLE CONTAINED PIPE PLUG VALVE CONTROL VALVE
SHUT OFF QUICK DISCONNECT SINGLE PORT
FC SPRING/DIAPHRAGM OPERATED
ELECTRICALLY TRACED HOSE COUPLING - DOUBLE END RADIAL DIAPHRAGM VALVE HV
BALANCING VALVE
SHUT OFF QUICK DISCONNECT DOUBLE PORT 001 S

3 WAY SOLENOID VALVE


STEAM TRACED LINE CONTINUATION PINCH CLAMP VALVE ZERO STATIC VALVE USE ONE OF THESE
X" SYMBOLS WHERE A HV
MINIMUM DEAD LEG IS 001 M
INSTRUMENT ELECTRICAL SIGNAL HOSE BARB CHECK VALVE DIAPHRAGM DESIRED. MOTO-OPERATED VALVE
BUTT WELD CAP BFP VALVE FC
QUICK DISCONNECT (ELECTRICAL) BACK FLOW PREVENTER ASSEMBLY
A" x B" PCV
INSTRUMENT AIR SUPPLY CONCENTRIC REDUCER L = 2D (WHEN 2D IS REQUIRED) 001
v v v v v v
(SPECIFY PRESSURE IF OTHER OR BACK PRESSURE REGULATOR
A" x B" BUTTERFLY VALVE
THAN 1 BARG) = FT (FITTING TIGHT) (SELF CONTAINED)
ECCENTRIC REDUCER PCV
INSTRUMENT PNEUMATIC SIGNAL NEEDLE VALVE 001
INGOLD FITTING PCV PRESSURE REDUCING VALVE
INSTRUMENT (HYDRAULIC) SIGNAL 001
3 WAY GLOBE VALVE (SELF CONTAINED)
CAPILLARY TUBE COMPRESSION FITTING CONSERVATION VENT
# PCV
SWAGELOCK CONNECTION 001
CONTROL SIGNAL (SOFT WIRED) 3 WAY BALL VALVE (T-PORT) BACK PRESSURE REGULATOR
(LINE ACTUATED)
ST STEAM TRAP
E EXISTING EQUIPMENT BOUNDARY 3 WAY BALL VALVE (L-PORT) FLUSH BOTTOM VALVE PCV
T LIQUID TRAP # 001
PRESSURE REDUCING VALVE
F FUTURE EQUIPMENT BOUNDARY HV HV
PIPE UNION # (LINE ACTUATED)
4 WAY BALL VALVE (T-PORT) 001 001 HV
S SKID EQUIPMENT BOUNDARY THREADED CONNECTION MIX-PROOF VALVES 001 M

FO FO
DOUBLE BLOCK AND BLEED ELECTRIC SOLENOID
# DIAPHRAGM VALVE
P PACKAGE EQUIPMENT BOUNDARY "Y" STRAINER 4 WAY BALL VALVE (L-PORT) PSV
001
CONTAINMENT VALVE
FA-XX

LINE SLOPE DIRECTION


FLAME ARRESTOR PRESSURE RELIEF VALVE
SPEC1 SPEC2 4 WAY BALL VALVE (X-PORT) SILENCER PSV
001
CHANGE OF PIPING SPEC AUTOMATIC AIR VENT #(ARROW DESIGNATES FAILURE POSITION)
DRAIN HUB HEMOSTAT VACUUM RELIEF VALVE
P = PROCESS PSV
P (UFD,S)
DIN TO ANSI ADAPTER 001
UFD = UTILITY FLOOR DRAIN
S = SOLVENT SEPTUM PRESSURE AND VACUUM
BIRDSCREEN
SAMPLING PORT RELIEF VALVE
AREA BREAK

DWG NO. BATTERY LIMIT TIE-IN SAMPLE


LINE CONTINUED ON DESIGNATOR BAG
DESCRIPTION ANOTHER DRAWING
*(FOR SYMBOLOGY SHOWN ABOVE,
DIRECTION OF FLOW IS LEFT TO RIGHT)
DWG NO. LINE CONTINUED FROM CONTINUATION
DESCRIPTION ANOTHER DRAWING LINE NUMBERING SYSTEM MANUAL VALVE IDENTIFICATION
0 REVISION TRIANGLE 0
0
1 1/2"-WFI-XXXXXXX-SST4 HC 0 XXX - S1XX - V - 001
PIPING SERVICE ABBREVIATIONS INSULATION
HC - HEAT CONSERVATION SEQUENTIAL NUMBER
SS = STAINLESS STEEL MF = MILL FINISH CC - COLD CONSERVATION VALVE CODE
CS = CARBON STEEL RA PP - PERSONNEL PROTECTION MV - MANUAL VALVE
EP = ELECTRO POLISHED SCH = SCHEDULE AS - ANTI SWEAT XV - AUTOMATED VALVE
MP = MECHANICAL POLISHED CH - COLD CONSERVATION CV - CHECK VALVE
BUT STEAMABLE YSV - STRAINER VALVE
OTHER ABBREVIATIONS PIPE SPECIFICATION SYSTEM NUMBER RELATED 0
SEQUENTIAL NUMBER TO EQUIPMENT CODE
@ = AT FP = FAIL POSITION MIN = MINUTE
BARG = BAR (GAUGE) FT = FITTING TIGHT MM = MILLIMETER P&ID DRAWING NUMBER PROCESS EQUIPMENT CODE
BTU = BRITISH THERMAL GAL = (US) GALLONS PSIG = POUNDS PER SQUARE SERVICE
UNIT GPM = (US) GALLONS PER MINUTE INCH (GAUGE) LINE SIZE
CIP = CLEAN IN PLACE HP = HIGH POINT SAT = SITE ACCEPTANCE
CSC = CAR SEAL CLOSED HR = HOUR TEST
PROJECT TITLE.
CSO = CAR SEAL OPEN L = LITERS SP = SAMPLE POINT CONSULTANT

HOSE / TUBE IDENTIFICATION PROJECT MARVEL -


DES. PRESS = DESIGN PRESSURE LC = LOCK CLOSED CONNECTION
CELL THERAPY MANUFACTURING
DIA = DIAMETER LO = LOCK OPEN SCFM= STANDARD CUBIC
FACILITY SINGAPORE
DWG = DRAWING LP = LOW POINT FEET PER MINUTE DRAWING TITLE.

XXXX - H - 001
EPCM

FAT = FACTORY ACCEPTANCE LPM = LITERS PER MINUTE SIP = STEAM IN PLACE
TEST M = METER TT = TANGENT TO TANGENT PIPING & INSTRUMENTATION DIAGRAM
SEQUENTIAL NUMBER LEAD SHEET 1 OF 3
V = VENDOR SUPPLIED
HOSE / TUBE CODE CLIENT

P&ID DRAWING NUMBER NOTICE!


This drawing, related detail drawings, and technical information supplied with
them are the property of TESSA. All equipment design and application data shown
NORTH
herein is confidential. No use or disclosure thereof may be made without written
permission from TESSA. CLIENT CLIENT
NOTE: THIS IS A COMPUTER PLOT. CHANGES MUST BE MADE ON THE CAD SYSTEM. DRAWING JOB
NO. NO.

B 19.06.2019 ISSUED FOR DESIGN RKresn SKamath NareshM APawar DRAWING JES REV
FILE PROJECT NO.
NAME NO.
A 27.05.2019 ISSUED FOR DESIGN RKresn SKamath SKamath APawar 0 10.10.2019 ISSUED FOR CONSTRUCTION RAhmad SKamath NareshM APawar
ORIGINATOR CHECKER APPROVER DATE SCALE JES

REVISION RKresn SKamath SKamath 27.05.2019 N.T.S. DRAWING


NO. 0
-
--