Professional Documents
Culture Documents
Environmental Requirements:
Wind Speed Standard: IBC 2018 Tilt: 0 degrees
Snow Load: 0 psf Existing Terrain: N-S Slope: 0 degrees
Wind Speed: 90 mph End Clamp Preference: Universal
Topographic Condition: Standard
Array Information:
Number of rows per array: 4 High (Landscape) Grounding Method: UL 2703 Listed
Number of columns per array: 10 columns Foundation Option: Standard Pier
Number of arrays: 1 arrays Bracing: Standard
Minimum Height of Leading Edge: 48 inches Vertical Pipe: 1.5 inches
Module Overhang: 16 inches Microinverter Attachment Kits: No
SnapNrack PV Mounting System ? www.snapnrack.com ? +(877)732-2860 ? 775 Fiero LN, Suite 200. San Luis Obispo, CA 93401 1 of 2
s (2.1.4) 2023-01-19T22:46:03-0500
STANDARD OPTIONS:
Maximum E-W post spacing: 97 inches
Adjusted E-W post spacing: 97 inches
N-S post spacing: 96 inches
Rails per Column: 2
Total Array Length: 54.8 feet
E-W exterior post distance: 48.5 feet
E-W exterior rail distance: 52.2 feet
Rail Span (RS): 96 inches
Rail Overhang (RO): 31.5 inches
Total Number of Modules: 40
Front Pier Depth: 30 inches
Back Pier Depth: 30 inches
NOTE: All pipe lengths are estimated to be slightly long. Pipe fittings will slightly reduce length of cross braces, and terrain variations may
effect lengths as well. Pipe is typically purchased from a plumbing supply in 21 foot sections. It is important to make sure the pipe is threaded
on both ends and includes a coupler. Use this coupler to connect pipe sections together for the Horizontal Pipe.
SnapNrack PV Mounting System ? www.snapnrack.com ? +(877)732-2860 ? 775 Fiero LN, Suite 200. San Luis Obispo, CA 93401 2 of 2
REVISION:
MODULE MOUNTING HARDWARE G 12/1/2013 NSSE UPDATE DR
SNAPNRACK UNIVERSAL END CLAMP H 2/26/2018 PZSE UPDATE DR
I 8/6/2020 PIPE TEE MJA
NOTE: (FOR END OF ROW) J 8/31/2021 PZSE UPDATE MKW
5
TYPICAL ARRAY TORQUE 5 16 " SS CLAMPS MODULE WITH 16 " STAINLESS
(FOUR MODULES SILVER HEX BOLTS HARDWARE USING WEDGE CLAMP
SHOWN) TO 10-16 FT-LBS
TORQUE 5 FOR MODULES WITHOUT AN UNDERSIDE
16 " SS
LIP USE SNAPNRACK TOP MOUNT END
BLACK HEX BOLTS CLAMPS
TO 7-9 FT-LBS
A
RAIL SHOWN
BEFORE MODULES
ARE INSTALLED SNAPNRACK PIPE CLAMP
THREADED PIPE
MODULE MID CLAMP
COUPLERS TO
ASSEMBLY
SNAPNRACK MATCH PIPE SIZE
GROUND RAIL
PIPE TO RAIL CONNECTION EXPLODED PIPE TO RAIL CONNECTION PIPE FITTING DETAILS
J
595 MARKET STREET, 29TH FLOOR SAN FRANCISCO, CA 94105 USA
PHONE (415) 580-6900 FAX (415) 580-6902
DRAFTER: M.WATKINS SNR-DC-00202 SERIES 200 SYSTEM DETAILS
DATE:
Solar Mounting Solutions THE INFORMATION IN THIS DRAWING IS CONFIDENTIAL AND PROPRIETARY. ANY
REPRODUCTION, DISCLOSURE, OR USE THEREOF IS PROHIBITED WITHOUT THE
APPROVED BY: B.ARBUCKLE 8/31/2021
WRITTEN CONSENT OF SUNRUN SOUTH LLC.
SEE ENGINEERING TABLES FOR REVISION:
SNAPNRACK UNIVERSAL MODULES SNAPNRACK G 12/1/2013 NSSE UPDATE DR
PIER DEPTHS AND SPAN END CLAMPS (SHOWN) MID CLAMP H 2/26/2018 PZSE UPDATE DR
LIMITATIONS. OR SNAPNRACK TOP ASSEMBLIES I 12/18/2020 PZSE UPDATE MKW
J 8/31/2021 PZSE UPDATE MKW
MOUNT END CLAMPS
UNLESS OTHERWISE SPECIFIED
IN ENGINEERING DOCS,
THE FOLLOWING
HOLLAENDER SINGLE ADJUSTABLE SOCKET TEES
VALUES APPLY. HORIZONTAL A CONNECT ANGLED BRACES TO VERTICAL PIPES
1.5" PIPE - 17-8 FOR 1.5" VERTICAL POSTS
MAX RAIL LENGTH (RL) IS 214": - 17-98 FOR 2" VERTICAL POSTS
MAX RAIL SPAN (RS) = 144"
MAX RAIL OVERHANG (RO) = 35"
BRACE C
(1.5" PIPE)
MAXIMUM MODULE WEIGHT IS
65 LBS VERTICAL POST
(1.5" OR 2" PIPE)
SNAPNRACK
CHANNEL NUT
SNAPNRACK
HOLLAENDER SINGLE SOCKET TEES
PIPE CLAMP
BRACE D BRACE A CONNECT HORIZONTALS TO VERTICAL POSTS
(1.5" PIPE) (1.5" PIPE) - 5EXT-8 FOR 1.5" VERTICAL POSTS
- 5-89 FOR 2" VERTICAL POSTS
(WITH ADDITIONAL 1/4"x1" SS DETAIL A
SELF-DRILLING FASTENER)
ISO VIEW OF RACKING ASSEMBLY
DETAILED VIEW OF PIPE TO RAIL AND BRACING INTERFACE
SNAPNRACK
HOLLAENDER SINGLE SOCKET TEES
PIPE CLAMP
BRACE D BRACE A CONNECT HORIZONTALS TO VERTICAL POSTS
(1.5" PIPE) (1.5" PIPE) - 5EXT-8 FOR 1.5" VERTICAL POSTS
- 5-89 FOR 2" VERTICAL POSTS
(WITH ADDITIONAL 1/4"x1" SS DETAIL A
SELF-DRILLING FASTENER)
ISO VIEW OF RACKING ASSEMBLY
DETAILED VIEW OF PIPE TO RAIL AND BRACING INTERFACE
SHEATHING, TYP.
RAFTER, TYP.
PIER DIAMETER PIER DIAMETER SECURE FLANGES
12" MIN, TYP. 12" MIN, TYP. TO SURFACE USING
GROUND SCREW DETAIL FLANGE MOUNT DETAIL APPROPRIATE HARDWARE
STANDARD PIER DETAIL STANDARD PIER DETAIL ON SLOPED GRADE
TO RESIST PULL OUT
FORCES OF 800 LBS
J
595 MARKET STREET, 29TH FLOOR SAN FRANCISCO, CA 94105 USA
PHONE (415) 580-6900 FAX (415) 580-6902
DRAFTER: M.WATKINS SNR-DC-00206 SERIES 200 FOUNDATION DETAILS
DATE:
Solar Mounting Solutions THE INFORMATION IN THIS DRAWING IS CONFIDENTIAL AND PROPRIETARY. ANY
REPRODUCTION, DISCLOSURE, OR USE THEREOF IS PROHIBITED WITHOUT THE
APPROVED BY: B.ARBUCKLE 8/31/2021
WRITTEN CONSENT OF SUNRUN SOUTH LLC.
REVISION:
A 2/26/2018 NEW SHEET DR
1
1-2" THREADED PIPE COUPLER. PIPE COUPLER
SHALL NOT OCCUR IN THE OVERHANG (CANTILEVER)
NOR SHALL IT OCCUR IN THE BACKSPAN OF THE
CANTILEVER WHICH IS DEFINED AS THE CLOSEST
ADJACENT SPAN TO THE CANTILEVER. PIPE COUPLER
SHALL BE LOCATED NO CLOSER THAN (PS)/6 FROM
A POST NOR FURTHER THAN (PS)/3 FROM A POST.
OVERHANG BACKSPAN
HORIZONTAL PIPE
(PS)/6 <X<(PS)/3
POST, TYP.
BRACES PER
CONFIGURATION
TABLES
A
595 MARKET STREET, 29TH FLOOR SAN FRANCISCO, CA 94105 USA
PHONE (415) 580-6900 FAX (415) 580-6902
DRAFTER: D.RYAN SNR-DC-00204 SERIES 200 PIPE SPLICE DETAIL
DATE:
Solar Mounting Solutions THE INFORMATION IN THIS DRAWING IS CONFIDENTIAL AND PROPRIETARY. ANY
REPRODUCTION, DISCLOSURE, OR USE THEREOF IS PROHIBITED WITHOUT THE
APPROVED BY: B.ARBUCKLE 2/26/2018
WRITTEN CONSENT OF SUNRUN SOUTH LLC.