You are on page 1of 55

PROPOSED AMAF HEADQUARTER

BUILDING (2B+G+3FLRS+RF)
PLOT NO. 2140909
@ AL GARHOUD, DUBAI

STRUCTURAL CALCULATIONS FOR CURTAIN WALL , 3.7


M HEIGHT GL42 AND SIMILAR

1
CURTAIN WALL STRUCTURAL CALCULATIONS

INTRODUCTION:
The following report contains the structural calculations for the STRIP CURTAIN WALL
for the PROPOSED AMAF HEADQUARTER BUILDING (2B+G+3FLRS+RF), PLOT NO.
2140909 @ AL GARHOUD, DUBAI ,This structural calculation is assessed as Per Bs 8118:
Part 1:1991. (Structural use of aluminum) with required support paper at latest of this
report. Maximum mullion reaction points are 3.7 m and span are 1.29 m. This
Calculations consider 3.7 m Height to be Maximum and Critical , hence this calculations
can be used for other Curtain Wall types and Similiar. GL 42 comes under Corner Areas.

GLASS DETAILS :
It consists of 6 mm outer glass + 16 mm air space + 6 mm inner pane.

DEFLECTION:

 Maximum deflection of framing members in direction normal to wall plane is


limited to 1/175 of clear span as per AAMA TIR A11 04 upto height 4110 mm

Deflection Criteria

For Span 4110 mm = 1/175

For Span > 4110 mm but < 12 m = 1/240 + 6.35 mm

2
3
4
5
6
7
8
ALUMINIUM PROPERTIES:
Density = 2710 kg/m3
Modulus of elasticity = 70000 N/mm2
Modulus of rigidity = 26600 N/mm2

LOAD COMBINATION ( BS 8118: Part 1:1991)

WIND LOAD FROM LEVEL TO HEIGHT 24.86 M (ROOF FLOOR LEVEL)


BS 6399‐2:1997 was a technical revision of CP3: Chapter V: Part 2 (now

Withdrawn) which incorporated the considerable advances made and experience

Gained in wind engineering since that time. The design wind load is assessed as per

BS: 6399: Part 2:1997, by standard method.

Basic wind speed(Vg) = 45 m/sec

9
(3 sec gust)
(As per the Dubai Muncipality)

The basic 3 sec wind speed is converted to mean hourly wind speed.

Basic wind speed = 45 m/sec


(3 sec gust)

Considering a Distance of 10 km from Sea(Country)


Terrain Building factor at 24.86 m height (Roof top Level) (Sb)
(Interpolation) =1.92

Hourly Wind Speed (Vb) =23.4 m/s

10
Maximum Suction is 1.829 kpa for Zone A ( Corner Areas)
Maximum Suction is 1.288 kpa for Middle Areas.
GL 42 comes under Corner Areas

11
CURTAIN WALLS STRUCTURAL
CALCULATION SCHEDULE

12
NAME TYPE L (M) W(SPAN)M WIND LOAD, TRIBUTARY AREA (M2) REMARKS TYPE OF CONNECTION
GL 01 C.C.W 7.95 1.7 13.515 FOLLOW CALCULATION OF GL 01 FIX
GL 01 A C.C.W 7.95 1.7 13.515 FOLLOW CALCULATION OF GL 01 FIX
GL 02 STRIP 3 1.246 3.738 FOLLOW CALCULATION OF GL 08 PINNED
GL 03 STRIP 3 1.254 3.762 FOLLOW CALCULATION OF GL 08 PINNED
GL 05 STRIP 3 1.31 3.93 FOLLOW CALCULATION OF GL 42 PINNED
GL 06 STRIP 3.45 1.31 4.5195 FOLLOW CALCULATION OF GL 42 PINNED
GL 07 STRIP 3.45 1.238 4.2711 FOLLOW CALCULATION OF GL 42 PINNED
GL 08 STRIP 3 1.255 3.765 FOLLOW CALCULATION OF GL 08 PINNED
GL 09 STRIP 4.3 1.33 5.719 FOLLOW CALCULATION OF GL 30 FIX
GL 10 STRIP 4.25 1.095 4.65375 FOLLOW CALCULATION OF GL 42 PINNED
GL 11 STRIP 3.58 1.55 5.549 FOLLOW CALCULATION OF GL 30 FIX
GL 12 STRIP 3.75 1.2 4.5 FOLLOW CALCULATION OF GL 42 PINNED
GL 13 STRIP 3 1.38 4.14 FOLLOW CALCULATION OF GL 42 PINNED
GL 14 STRIP 3 1.2 3.6 FOLLOW CALCULATION OF GL 08 PINNED
GL 14 A STRIP 3 1.2 3.6 FOLLOW CALCULATION OF GL 08 PINNED
GL 14 B STRIP 3 1.2 3.6 FOLLOW CALCULATION OF GL 08 PINNED
GL 15 A STRIP 3.45 1.2 4.14 FOLLOW CALCULATION OF GL 42 PINNED
GL 15 B STRIP 3.6 1.2 4.32 FOLLOW CALCULATION OF GL 42 PINNED
GL 15 C STRIP 3.45 1.2 4.14 FOLLOW CALCULATION OF GL 42 PINNED
GL 15 D STRIP 3.45 1.2 4.14 FOLLOW CALCULATION OF GL 42 PINNED
GL 16 STRIP 4.15 1.1 4.565 FOLLOW CALCULATION OF GL 42 PINNED
GL 17 STRIP 3.05 1.12 3.416 FOLLOW CALCULATION OF GL 08 PINNED
GL 18 STRIP 2.96 1.125 3.33 FOLLOW CALCULATION OF GL 08 PINNED
GL 19 STRIP 1.2 0.975 1.17 FOLLOW CALCULATION OF GL 34 PINNED
GL 20 STRIP 1.2 0.975 1.17 FOLLOW CALCULATION OF GL 34 PINNED
GL 21 STRIP 1.2 0.95 1.14 FOLLOW CALCULATION OF GL 34 PINNED
GL 22 STRIP 1.2 0.95 1.14 FOLLOW CALCULATION OF GL 34 PINNED
GL 23 A STRIP 3 1.37 4.11 FOLLOW CALCULATION OF GL 42 PINNED
GL 23 B STRIP 3 1.255 3.765 FOLLOW CALCULATION OF GL 08 PINNED
GL 23 C STRIP 3 1.325 3.975 FOLLOW CALCULATION OF GL 42 PINNED
GL 24 A STRIP 3 1.365 4.095 FOLLOW CALCULATION OF GL 42 PINNED
GL 24 B STRIP 3 1.255 3.765 FOLLOW CALCULATION OF GL 08 PINNED

13
GL 24 C STRIP 3 1.255 3.765 FOLLOW CALCULATION OF GL 08 PINNED
GL 25 STRIP 3.45 1.255 4.32975 FOLLOW CALCULATION OF GL 42 PINNED
GL 26 STRIP 3.45 0.785 2.70825 FOLLOW CALCULATION OF GL 34 PINNED
GL 27 STRIP 3.45 1.255 4.32975 FOLLOW CALCULATION OF GL 42 PINNED
GL 28 STRIP 3.45 1.255 4.32975 FOLLOW CALCULATION OF GL 42 PINNED
GL 29 STRIP 3.45 1.255 4.32975 FOLLOW CALCULATION OF GL 42 PINNED
GL 30 STRIP 4.5 1.185 5.3325 FOLLOW CALCULATION OF GL 30 FIX
GL 31 STRIP 3.15 1.055 3.32325 FOLLOW CALCULATION OF GL 08 PINNED
GL 32 STRIP 3 0.995 2.985 FOLLOW CALCULATION OF GL 08 PINNED
GL 33 STRIP 3.2 1.095 3.504 FOLLOW CALCULATION OF GL 08 PINNED
GL 34 STRIP 2.85 0.7475 2.130375 FOLLOW CALCULATION OF GL 34 PINNED
GL 35 STRIP 2.85 0.7475 2.130375 FOLLOW CALCULATION OF GL 34 PINNED
GL 36 STRIP 2.85 0.695 1.98075 FOLLOW CALCULATION OF GL 34 PINNED
GL 37 STRIP 2.85 0.7475 2.130375 FOLLOW CALCULATION OF GL 34 PINNED
GL 38 STRIP 2.85 0.7475 2.130375 FOLLOW CALCULATION OF GL 34 PINNED
GL 39 STRIP 2.85 0.6975 1.987875 FOLLOW CALCULATION OF GL 34 PINNED
GL 40 STRIP 3.6 1.485 5.346 FOLLOW CALCULATION OF GL 30 FIX
GL 41 STRIP 3.55 1.43 5.0765 FOLLOW CALCULATION OF GL 30 FIX
GL 42 STRIP 3.7 1.29 4.773 FOLLOW CALCULATION OF GL 42 PINNED
GL 43 STRIP 3.5 1.055 3.6925 FOLLOW CALCULATION OF GL 08 PINNED
GL 44 A STRIP 3 1.2 3.6 FOLLOW CALCULATION OF GL 08 PINNED
GL 44 B STRIP 3 1.2 3.6 FOLLOW CALCULATION OF GL 08 PINNED
GL 44 C STRIP 3.025 1.2 3.63 FOLLOW CALCULATION OF GL 08 PINNED
GL 45 STRIP 3.955 1.307 5.169185 FOLLOW CALCULATION OF GL 30 FIX
GL 46 STRIP 3 1.307 3.921 FOLLOW CALCULATION OF GL 42 PINNED

14
DESIGN OF NON CONTINOUS CW
GL42
THIS TYPE FALLS UNDER CORNER
AREAS

15
08//,21$1$/<6,6
*(

16
13
MULLION PROPERTIES(BS 8118:1)
GE‐13938

GENERAL PROPERTIES:
AA6063‐T6 Unwelded
ρo = 160.00 Mpa Ultimate Tensile Stress (Table 4.1)
ρv = 95.00 Mpa Limiting Shear Stress (Table 4.1)
ρa = 175.00 Mpa Limiting Axial Stress (Table 4.1)
E= 70000.00 Mpa Modulus of elasticity of Aluminum

SECTION PROPERTIES OF MULLION:

b= 50.00 mm Profile width


d= 150.00 mm Profile depth
tw = 2.80 mm Profile web thickness
tf = 3.50 mm Profile flange thickness
2
Am = 1349 mm Cross ‐ sectional area
4
Ix = 4345074 mm Moment of inertia at major axis
Cy =yc 85.4 mm Distance from neutral y ‐ axis to extreme fibers (+)
yo= ‐64.6 mm Distance from neutral y ‐ axis to extreme fibers(‐)
4
Iy = 532604 mm Moment of inertia at minor axis
Cx = 25.00 mm Distance from neutral x ‐ axis to extreme fibers
3
SCX = IX/CY= 50879.09 mm Elastic section modulus at x‐x axis
3
SCY = IY/CX= 21304.16 mm Elastic section modulus at y‐y axis

DEAD LOAD CALCULATIONS

w1 = 1290.00 mm Panel Width 1


w2 = 1290.00 mm Panel Width 2
Tw = (w1+w2) / 2 mm Tributary width of loaded area
Tw = 1290.00 mm
hm = 3700.00 mm Max. height of mullion
tg = 14.00 mm Assume thickness of glass (6 + A + 6)
Wtrans = 0.04 N/mm Weight of transom
3
ωg = 0.00002450 N/mm Density of glass
DL = weight of (glazing + transoms)
DL = 1.1*ωg*tg*tw + 2*Wtrans
DL = 0.6 kN/m

17
WIND LOAD DISTRIBUTION

Wp = 1.829 kPa Wind pressure (Zone A)


Wp = Wp*tw
Wp = 2.36 kN/m Uniformly distributed wind load at typical area

CHECK FOR DEFLECTION DUE TO WL:

Input Data:
Wp = 2.36 kN/m Uniformly distributed wind load at typical area
hm = 3700.00 mm Max. height of mullion
E= 70000.00 Mpa Modulus of elasticity of aluminum
Ix = 4345074 mm4 Moment of inertia at major axis
Cx = 25.00 mm Distance from neutral x ‐ axis to extreme fibers

δmax = 19.12 mm Maximum deflection for mullion generated from staad


δallow = hm/240 + 6.35mm Project Specifications
δallow = 21.76666667 mm Allowable deflection for mullion

Since : δmax < δallow O.K!

SECTION CLASSIFICATION:
According to BS 8118: Part 1: 1991 ‐ table 4.3

β < β1 Fully compact


β1 < β < β o Semi‐compact
β > βo Slender

ε = √(250 MPa/po) Slenderness Limit Constant


ε= 1.25

βo = 22*ε 27.5 Limit for a semi‐compact section


β1 = 18*ε 22.5 Limit for a fully compact section

ELEMENT CLASSIFICATION FOR WEB ELEMENT:


yo/yc= ‐0.76
gr = 0.45 Stress Gradient Coefficient (Figure 4.2)
βw = (gr*d/tw) Slenderness Parameter
βw = 24.11
SEMI‐COMPACT

ELEMENT CLASSIFICATION FOR FLANGE ELEMENT:

βf = b/tf Slenderness Parameter


βf = 14.29
FULLY COMPACT!

CHECK FOR BENDING MOMENT RESISTANCE OF MULLION:

3
Wx=SCX 50879.09 mm
ɤm = 1.2
Mz = 4.846 kN‐m Factored max.bending moment generated from STAAD.

MRX = (ρo*Wx)/ɤm
MRX = 6.78 kN‐m

Since:Mz< MRX O.K!

18
CHECK FOR SHEAR RESISTANCE:
According to BS 8118: Part 1: 1991 ‐ table 4.3,
d w < 49 * ε Fully Compact
tw

d w > 49 * ε Slender
tw
=√ (250 )
po

ε= 1.25

d 53.57
tw
THE SECTION IFULLY COMPACT!

Vmax= 5.239 kN Factored max.shear generated from STAAD


N w= 1 Number of webs
Avw= 0.8*Nw*d*tw Effective shear area
3
Avw= 336 mm
VRSWY= (ρV*AVW)/ɤm Factored shear resistance
VRSWY= 26.60 kN
Since:Vmax< VRO.K!

CHECK FOR AXIAL RESISTANCE FOR COMPRESSION MEMBERS:


According to BS 8118: Part 1: 1991 ‐ table 4.7.3

Pcw = 2.352 Factored max.axial force (Compression) generated from STAA


P1 = ρa According 4.7.6.2
P1 = 175 MPa
e= 2550.00 mm Distance between Transoms
K= 0.7 Effective length factor for Lateral Torsional Buckling
l= e*K mm Effective length for Lateral Torsional Buckling
l= 1785 mm
ry= 19.87 mm Minor Axis Radius of Gyration
λ= l/ry
λ= 89.83
Ps = 115 MPa Buckling stress ‐ Figure 4.10(a)
PRC = (Ps*Am)/ɤm
PRC = 129.28 kN
Since:Pcw< PRC O.K!
CHECK FOR LOCAL SQUASHING RESISTANCE FOR COMPRESSION MEMBERS:
According BS 8118: Part 1: 1991 ‐ 4.7.7
PRS = (ρa*Am/ɤm)
PRS = 196.73 kN
Since:Pcw< PRS O.K!

CHECK FOR BENDING WITH AXIAL FORCE:


According BS 8118: Part 1: 1991 ‐ 4.8
Section check
SC= (PCW/PRS+MZ/MRX)
SC= 0.73
Since:SC< 1.0 O.K!
LATERAL TORSIONAL BUCKLING CHECK:
According BS 8118: Part 1: 1991 ‐ 4.5.6

=√ (250 )
po

ε= 1.25
For Unwelded , Fully Compact Sections,4.5.6.5
ρ1 =ρo

19
For Other Sections , Including Hybrid ,4.5.6.5
ρ1 = (ɤm*MRX)/Wx
ρ1 = 160.00 MPa
e= 2550 mm Distance between Transoms
K= 0.7 Effective length factor for Lateral Torsional Buckling
l= e*K mm Effective length for Lateral Torsional Buckling
l= 1785 mm
ry= 19.87 mm Minor Axis Radius of Gyration
λ= l/ry
λ= 89.83
From Fig.4.9
ps= 115 MPa
MRS= (ps*Wx/ɤm)
MRS= 4.88 kN‐m
Since:Mz< MRS O.K!

20
BEARING CAPACITY OF SECTION
The bearing capacity of the connected ply is given by the following.
∗ ∗ ∗ ∗
BRP= According 6.4.4
ɤ

N= 2 Number of Flanges or Webs Connecting to Screw/Bolt


db= 14 mm Dia of Hole (1 NOS M 12 BOLT)
tw = 2.80 mm Wall Thickness
db/t= 5.00
C= 2 When db/t <10
C= 20t/db When 10< db/t <13
C= 1.5 When db/t >13
Hence C= 2
BRP= 22.87 kN
Rwind = 6.767 kN Factored Reaction due to 1.2 Wind Load
Rdead = 5.021 kN Factored Reaction due to 1.2 Dead Load
√ 22
Rresultant = kN
Rresultant = 8.43 kN
Since:Rresultant< BRP O.K!
THERMAL EXPANSION
ΔL = L x ά x ΔT Deflecton Due to thermal loads
L= 3700.00 mm Length of Member
ά= 0.000023 mm.C Coeifficient of Thermal Expansion
ΔT= 40 Temperature Gradient
ΔL = 3.40 mm
EXPANSION GAP PROVIDED 10 MM , HENCE O.K!

21
67$$'$1$/<6,6

22
19
Job No Sheet No Rev
1
Part
Software licensed to
Job Title Ref

By Date26-Apr-16 Chd

Client File GL-42.std Date/Time 24-Jan-2021 13:07

Job Information
Engineer Checked Approved

Name:
Date: 26-Apr-16

Project ID
Project Name

Structure Type PLANE FRAME

Number of Nodes 2 Highest Node 2


Number of Elements 1 Highest Beam 1

Number of Basic Load Cases -2


Number of Combination Load Cases 3

Included in this printout are data for:


All The Whole Structure

Included in this printout are results for load cases:


Type L/C Name

Primary 1 DEAD LOAD


Primary 2 WIND LOAD
Combination 3 DL+WL
Combination 4 1.2DL+1.2WL
Combination 5 1.35DL+1.5WL

Section Properties
Prop Section Area Iyy Izz J Material
(cm2) (cm4) (cm4) (cm4)
1 Prismatic General 11.180 67.887 434.510 1.000 ALUMINUM

Combination Load Cases


Comb. Combination L/C Name Primary Primary L/C Name Factor

3 DL+WL 1 DEAD LOAD 1.00


2 WIND LOAD 1.00
4 1.2DL+1.2WL 1 DEAD LOAD 1.20
2 WIND LOAD 1.20
5 1.35DL+1.5WL 1 DEAD LOAD 1.35
2 WIND LOAD 1.50

Print Time/Date: 24/01/2021 16:00 STAAD.Pro V8i (SELECTseries 6) 20.07.11.90 Print Run 1 of 10

23
Job No Sheet No Rev
2
Part
Software licensed to
Job Title Ref

By Date26-Apr-16 Chd

Client File GL-42.std Date/Time 24-Jan-2021 13:07

3.700m

Y
X
Z Load 4

GE 13938 PROPERTIES.

3.700m

Y -0.500 kN/m
X
Z Load 1

WEIGHT OF (GLAZING + TRANSOMS)

Print Time/Date: 24/01/2021 16:00 STAAD.Pro V8i (SELECTseries 6) 20.07.11.90 Print Run 2 of 10

24
Job No Sheet No Rev
3
Part
Software licensed to
Job Title Ref

By Date26-Apr-16 Chd

Client File GL-42.std Date/Time 24-Jan-2021 13:07

3.700m

Y
X
Z Load 2

2.360 kN/m

WINDLOAD 2.36 KN/M

Print Time/Date: 24/01/2021 16:00 STAAD.Pro V8i (SELECTseries 6) 20.07.11.90 Print Run 3 of 10

25
Job No Sheet No Rev
4
Part
Software licensed to
Job Title Ref

By Date26-Apr-16 Chd

Client File GL-42.std Date/Time 24-Jan-2021 13:07

Max: 19.117 mm

Y
X Load 2 : Displacement
Z Displacement - mm

DL+WL,DEFLECTION, 19.117 MM<3700/175=21.14 MM (O.K) !

Print Time/Date: 24/01/2021 16:00 STAAD.Pro V8i (SELECTseries 6) 20.07.11.90 Print Run 4 of 10

26
Job No Sheet No Rev
5
Part
Software licensed to
Job Title Ref

By Date26-Apr-16 Chd

Client File GL-42.std Date/Time 24-Jan-2021 13:07

Max: -4.846 kN-m

Y
X Load 4 : Bending Z
Z Moment - kN-m

MZ,1.2DL+1.2WL=4.846 KNM

Print Time/Date: 24/01/2021 16:00 STAAD.Pro V8i (SELECTseries 6) 20.07.11.90 Print Run 5 of 10

27
Job No Sheet No Rev
6
Part
Software licensed to
Job Title Ref

By Date26-Apr-16 Chd

Client File GL-42.std Date/Time 24-Jan-2021 13:07

Y
X Load 4 : Shear Y
Z Force - kN

Max: 5.239 kN

Fy ,1.2DL+1.2WL=5.239 KN

Print Time/Date: 24/01/2021 16:00 STAAD.Pro V8i (SELECTseries 6) 20.07.11.90 Print Run 6 of 10

28
Job No Sheet No Rev
7
Part
Software licensed to
Job Title Ref

By Date26-Apr-16 Chd

Client File GL-42.std Date/Time 24-Jan-2021 13:07

0 kN

Y
X Load 4 : Axial Force
Z Force - kN
2.352 kN

Fx 1.2DL+1.2WL=2.352 KN

Print Time/Date: 24/01/2021 16:00 STAAD.Pro V8i (SELECTseries 6) 20.07.11.90 Print Run 7 of 10

29
Job No Sheet No Rev
8
Part
Software licensed to
Job Title Ref

By Date26-Apr-16 Chd

Client File GL-42.std Date/Time 24-Jan-2021 13:07

X = -4.366 kN
Y = FREE
Z = 0.000 kN
MX = FREE
MY = FREE
MZ = FREE

X = -4.366 kN
Y = 1.960 kN
Z = 0.000 kN
MX = FREE
MY = FREE
MZ = FREE

Y
X
Z Load 3

REACTION, DL+WL

Print Time/Date: 24/01/2021 16:00 STAAD.Pro V8i (SELECTseries 6) 20.07.11.90 Print Run 8 of 10

30
Job No Sheet No Rev
9
Part
Software licensed to
Job Title Ref

By Date26-Apr-16 Chd

Client File GL-42.std Date/Time 24-Jan-2021 13:07

X = -5.239 kN
Y = FREE
Z = 0.000 kN
MX = FREE
MY = FREE
MZ = FREE

X = -5.239 kN
Y = 2.352 kN
Z = 0.000 kN
MX = FREE
MY = FREE
MZ = FREE

Y
X
Z Load 4

REACTION, 1.2DL+1.2WL

Print Time/Date: 24/01/2021 16:00 STAAD.Pro V8i (SELECTseries 6) 20.07.11.90 Print Run 9 of 10

31
Job No Sheet No Rev
10
Part
Software licensed to
Job Title Ref

By Date26-Apr-16 Chd

Client File GL-42.std Date/Time 24-Jan-2021 13:07

X = -6.549 kN
Y = FREE
Z = 0.000 kN
MX = FREE
MY = FREE
MZ = FREE

X = -6.549 kN
Y = 2.646 kN
Z = 0.000 kN
MX = FREE
MY = FREE
MZ = FREE

Y
X
Z Load 5

REACTION,1.35 DL+1.5WL (ETAG)

Print Time/Date: 24/01/2021 16:00 STAAD.Pro V8i (SELECTseries 6) 20.07.11.90 Print Run 10 of 10

32
75$1620$1$/<6,6
*(

33
30
TRANSOM PROPERTIES (BS 8118:1)
GE‐13938

GENERAL PROPERTIES:
AA6063‐T6 Unwelded
ρo = 160.00 Mpa Ultimate Tensile Stress (Table 4.1)
ρv = 95.00 Mpa Limiting Shear Stress (Table 4.1)
ρa = 175.00 Mpa Limiting Axial Stress (Table 4.1)
E= 70000.00 Mpa Modulus of elasticity of Aluminum

SECTION PROPERTIES OF TRANSOM:

b= 50.00 mm Profile width


d= 150.00 mm Profile depth
tw = 2.80 mm Profile web thickness
tf = 3.50 mm Profile flange thickness
Am = 1349 mm2 Cross ‐ sectional area
Ix = 4345074 mm4 Moment of inertia at major axis
Cy =yc 85.4 mm Distance from neutral y ‐ axis to extreme fibers (+)
yo= ‐64.6 mm Distance from neutral y ‐ axis to extreme fibers(‐)
Iy = 532603 mm4 Moment of inertia at minor axis
Cx = 25.00 mm Distance from neutral x ‐ axis to extreme fibers
3
SCX = IX/CY= 50879.09 mm
3
SCY = IY/CX= 21304.12 mm

DEAD LOAD CALCULATIONS

Lt = 1290.00 mm Length of transom


hgt = 1150.00 mm Height of glass at top
hgb = 2550 mm Height of glass at bottom
th = (hgt + hgb)/2 mm
th = 2425.00 mm Tributary height of loaded area
tg = 12.00 mm Assume thickness of glass (6 + A + 6)
3
ωg = 0.00002930 N/mm Density of glass (@45 kg/m2)
2
wg= 0.00044 N/mm Unit weight of glass (@45 kg/m2)
DL = ωg*tg*th *Lt
DL = 1.10 kN Dead load
WIND LOAD DISTRIBUTION
Wp = 1.829 kPa Wind pressure
Wp = Wp*th
Wp = 4.44 kN/m Uniformly distributed wind load at typical area

34
CHECK FOR DEFLECTION DUE TO SW+ DL:
Normal to the plane of the wall

hgb=2550 (MAX)
P P

a a 322.5 mm
Lt=1290
P= DL/2 Weight of glass on Setting Block
P= 0.55 kN
a= Lt/4 The glass unit is supported on 2 nos. setting blocks as shown
a= 322.5 mm
Deflection Of Transom Due To Weight Of Glass
Deflection of transom P x a x (3 x Lt2 – 4 x a2)
(In‐plane deflection) 24 x E x
δDead= 0.99 mm
δAllow= Lt /1000
δAllow= 1.29 Allowable vertical deflection for transom
Since : δDead < δAllow O.K!

Deflection Of Transom Due To Wind Load


Deflection of transom 5 x Wp x Lt4
(Due to Wind Load) 384 x E x
δWind= 0.53 mm
δAllow= Lt /200
δAllow= 6.45 mm Allowable Horizontal deflection for transom
Since : δWind < δAllow O.K!

SECTION CLASSIFICATION:
According to BS 8118: Part 1: 1991 ‐ table 4.3

β < β1 Fully compact


β1 < β < β o Semi‐compact
β > βo Slender

ε= √(250 MPa/ρo) Slenderness Limit Constant


ε= 1.25

βo = 22*ε 27.5 Limit for a semi‐compact section


β1 = 18*ε 22.5 Limit for a fully compact section

ELEMENT CLASSIFICATION FOR WEB ELEMENT:


yo/yc= ‐0.76
gr = 0.45 Stress Gradient Coefficient (Figure 4.2)
βw = (gr*d/tw) Slenderness Parameter
βw = 24.11
SEMI‐COMPACT

ELEMENT CLASSIFICATION FOR FLANGE ELEMENT:

βf = b/tf Slenderness Parameter


βf = 14.29
FULLY COMPACT!

35
CHECK FOR BENDING MOMENT RESISTANCE OF TRANSOM:

3
Wx = 50879.09 mm
ɤm = 1.2
Mz = (1.2*Wp *Lt2 )/8 Actual Factored max.bending moment .
Mz = 1.11 kN‐m
MRX = (ρo*Wx)/ɤm Allowable bending moment .
MRX = 6.78 kN‐m

Since:Mz< MRX O.K!

CHECK FOR SHEAR RESISTANCE:


According to BS 8118: Part 1: 1991 ‐ table 4.3,
d w < 49 * ε Fully Compact
tw

d w > 49 * ε Slender
tw
=√ (250 )
po
ε= 1.25

d 53.57
tw
THE SECTION IS FULLY COMPACT!
Vmax= (1.2*Wp*Lt)/2 Factored max.shear
Vmax= 3.43 kN
Nw = 2 Number of webs
Avw= 0.8*Nw*d*tw Effective shear area
3
Avw= 672 mm
VRSWY= (ρV*AVW)/ɤm Factored shear resistance
VRSWY= 53.20 kN
Since:Vmax< VRSWY O.K!

36
$1&+25$*($1'
%$6(3/$7(

37
34
www.hilti-me.com
GL 42 BOTTOM , BP THK 6 MM Profis Anchor 2.9.1
Company: Page: 1
Specifier: Project:
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 1/24/2021
E-Mail:

Specifier's comments:

1 Input data
Anchor type and diameter: HST2 M12 hmin1
Return period (service life in years): 50
Seismic/Filling set or any suitable annular gap filling solution
Effective embedment depth: hef = 70 mm, hnom = 80 mm
Material:
Evaluation Service Report: ETA-15/0435
Issued I Valid: 12/21/2017 | -
Proof: SOFA design method + fib (07/2011) - after ETAG testing
Stand-off installation: eb = 0 mm (no stand-off); t = 3 mm
Anchor plate: S 275; E = 210,000.00 N/mm2; fyk = 275.00 N/mm2; gMs = 1.000
lx x ly x t = 180 mm x 150 mm x 3 mm; (Recommended plate thickness: calculated (3 mm))
Profile: Rectangular hollow, ; (L x W x T) = 125 mm x 50 mm x 2 mm
Base material: uncracked concrete, C40/50, fc,cyl = 40.00 N/mm2; h = 250 mm
Installation: hammer drilled hole, Installation condition: Dry
Reinforcement: no reinforcement or reinforcement spacing >= 150 mm (any Ø) or >= 100 mm (Ø <= 10 mm)
no longitudinal edge reinforcement

R
- The anchor calculation is based on a rigid anchor plate assumption.

Geometry [mm] & Loading [kN, kNm]

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 38
www.hilti-me.com Profis Anchor 2.9.1
Company: Page: 2
Specifier: Project:
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 1/24/2021
E-Mail:

2 Load case/Resulting anchor forces y

Load case: Design loads


3 4
Anchor reactions [kN]
Tension force: (+Tension, -Compression)
Anchor Tension force Shear force Shear force x Shear force y
1 0.662 1.637 1.637 0.000
x
2 0.662 1.637 1.637 0.000
3 0.662 1.637 1.637 0.000 Tension
4 0.662 1.637 1.637 0.000

max. concrete compressive strain: - [‰] 1 2


max. concrete compressive stress: - [N/mm2]
resulting tension force in (x/y)=(0/0): 2.646 [kN]
resulting compression force in (x/y)=(0/0): 0.000 [kN]

Anchor forces are calculated based on the assumption of a rigid anchor plate.

3 Tension load SOFA (fib (07/2011), section 10.1)


Load [kN] Capacity [kN] Utilization bN [%] Status
Steel Strength* 0.662 32.000 3 OK
Pullout Strength* 0.662 18.856 4 OK
Concrete Breakout Strength** 2.646 50.740 6 OK
Splitting failure** 2.646 67.014 4 OK
* anchor having the highest loading **anchor group (anchors in tension)

3.1 Steel Strength


NRk,s [kN] gM,s NRd,s [kN] NSd [kN]
44.800 1.400 32.000 0.662

3.2 Pullout Strength


NRk,p [kN] yc gM,p NRd,p [kN] NSd [kN]
20.000 1.414 1.500 18.856 0.662

3.3 Concrete Breakout Strength


Ac,N [mm2] A0c,N [mm2] y A,N ccr,N [mm] scr,N [mm]
84,800 44,100 1.923 105 210
ec1,N [mm] y ec1,N ec2,N [mm] y ec2,N y s,N y re,N
0 1.000 0 1.000 0.971 1.000
k1 N0Rk,c [kN] gM,c NRd,c [kN] NSd [kN]
11.000 40.745 1.500 50.740 2.646
Group anchor ID
1-4

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 39
www.hilti-me.com Profis Anchor 2.9.1
Company: Page: 3
Specifier: Project:
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 1/24/2021
E-Mail:

3.4 Splitting failure


Ac,N [mm2] A0c,N [mm2] y A,N ccr,sp [mm] scr,sp [mm] y h,sp
84,800 44,100 1.923 105 210 1.321
ec1,N [mm] y ec1,N ec2,N [mm] y ec2,N y s,N y re,N k1
0 1.000 0 1.000 0.971 1.000 11.000
N0Rk,c [kN] gM,sp NRd,sp [kN] NSd [kN]
40.745 1.500 67.014 2.646
Group anchor ID
1-4

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 40
www.hilti-me.com Profis Anchor 2.9.1
Company: Page: 4
Specifier: Project:
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 1/24/2021
E-Mail:

4 Shear load SOFA (fib (07/2011), section 10.2)


Load [kN] Capacity [kN] Utilization bV [%] Status
Steel Strength (without lever arm)* 1.637 25.120 7 OK
Steel failure (with lever arm)* N/A N/A N/A N/A
Pryout Strength** 6.549 111.627 6 OK
Concrete edge failure in direction x+** 3.275 20.331 17 OK
* anchor having the highest loading **anchor group (relevant anchors)

4.1 Steel Strength (without lever arm)


VRk,s [kN] gM,s VRd,s [kN] VSd [kN]
31.400 1.250 25.120 1.637

4.2 Pryout Strength


Ac,N [mm2] A0c,N [mm2] y A,N ccr,N [mm] scr,N [mm] k4
84,800 44,100 1.923 105 210 2.200
ec1,V [mm] y ec1,N ec2,V [mm] y ec2,N y s,N y re,N
0 1.000 0 1.000 0.971 1.000
N0Rk,c [kN] gM,c,p VRd,cp [kN] VSd [kN]
40.745 1.500 111.627 6.549
Group anchor ID
1-4

4.3 Concrete edge failure in direction x+


lf [mm] dnom [mm] kV a b
70 12.0 2.400 0.064 0.059
c1 [mm] Ac,V [mm2] A0c,V [mm2] y A,V
170 155,000 130,050 1.192
y s,V y h,V y a,V ec,V [mm] y ec,V y re,V y 90°,V
1.000 1.010 1.000 0 1.000 1.000 2.000
V0Rk,c [kN] n1 gM,c VRd,c [kN] VSd [kN]
50.670 2 1.500 20.331 3.275
Note: Resistance limit acc. to fib (07/2011) Eq. (10.2-6) is governing

5 Combined tension and shear loads SOFA (fib (07/2011), section 10.3)
bN bV a Utilization bN,V [%] Status
steel 0.021 0.065 2.000 1 OK
concrete 0.052 0.161 1.500 8 OK

baN + baV <= 1

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 41
www.hilti-me.com Profis Anchor 2.9.1
Company: Page: 5
Specifier: Project:
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 1/24/2021
E-Mail:

6 Displacements (highest loaded anchor)


Short term loading:
NSk = 0.490 [kN] dN = 0.005 [mm]
VSk = 1.213 [kN] dV = 0.224 [mm]
dNV = 0.224 [mm]
Long term loading:
NSk = 0.490 [kN] dN = 0.057 [mm]
VSk = 1.213 [kN] dV = 0.332 [mm]
dNV = 0.337 [mm]

Comments: Tension displacements are valid with half of the required installation torque moment for uncracked concrete! Shear displacements are valid
without friction between the concrete and the anchor plate! The gap due to the drilled hole and clearance hole tolerances are not included in this
calculation!

The acceptable anchor displacements depend on the fastened construction and must be defined by the designer!

7 Warnings
• The anchor design methods in PROFIS Anchor require rigid anchor plates per current regulations (ETAG 001/Annex C, EOTA TR029, etc.). This means load
re-distribution on the anchors due to elastic deformations of the anchor plate are not considered - the anchor plate is assumed to be sufficiently stiff, in
order not to be deformed when subjected to the design loading. PROFIS Anchor calculates the minimum required anchor plate thickness with FEM to
limit the stress of the anchor plate based on the assumptions explained above. The proof if the rigid anchor plate assumption is valid is not carried out by
PROFIS Anchor. Input data and results must be checked for agreement with the existing conditions and for plausibility!
• The accessory list in this report is for the information of the user only. In any case, the instructions for use provided with the product have to be followed
to ensure a proper installation.
• The design method fib (07/2011) assumes that no hole clearance between the anchors and the fixture is present. This can be achieved by filling the gap
with mortar of sufficient compressive strength (e.g. by using the HILTI Seismic/Filling set) or by other suitable means
• The compliance with current standards (e.g. EC3) is the responsibility of the user
• Checking the transfer of loads into the base material is required in accordance with fib (07/2011)!
• The characteristic bond resistances depend on the return period (service life in years): 50

Fastening meets the design criteria!

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 42
www.hilti-me.com Profis Anchor 2.9.1
Company: Page: 6
Specifier: Project:
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 1/24/2021
E-Mail:

8 Installation data
Anchor plate, steel: S 275; E = 210,000.00 N/mm2; fyk = 275.00 N/mm Anchor type and diameter: HST2 M12 hmin1
Profile: Rectangular hollow, ; (L x W x T) = 125 mm x 50 mm x 2 mm Installation torque: 0.060 kNm
Hole diameter in the fixture: df = 14 mm Hole diameter in the base material: 12 mm
Plate thickness (input): 3 mm Hole depth in the base material: 97 mm
Recommended plate thickness: calculated (3 mm) Minimum thickness of the base material: 140 mm
Drilling method: Hammer drilled
Cleaning: Manual cleaning of the drilled hole according to instructions for use
is required.

8.1 Recommended accessories

Drilling Cleaning Setting


• Suitable Rotary Hammer • Manual blow-out pump • Seismic/Filling set
• Properly sized drill bit • Torque wrench
• Hammer
y

90 90

20
3 4

75
110

x
75

1 2
20

55 70 55

Coordinates Anchor [mm]


Anchor x y c-x c+x c-y c+y
1 -35 -55 95 170 - -
2 35 -55 165 100 - -
3 -35 55 95 170 - -
4 35 55 165 100 - -

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 43
www.hilti-me.com Profis Anchor 2.9.1
Company: Page: 7
Specifier: Project:
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 1/24/2021
E-Mail:

9 Remarks; Your Cooperation Duties


• Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles, formulas and
security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be strictly
complied with by the user. All figures contained therein are average figures, and therefore use-specific tests are to be conducted prior to using the
relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the data you put in. Therefore, you
bear the sole responsibility for the absence of errors, the completeness and the relevance of the data to be put in by you. Moreover, you bear sole
responsibility for having the results of the calculation checked and cleared by an expert, particularly with regard to compliance with applicable norms
and permits, prior to using them for your specific facility. The Software serves only as an aid to interpret norms and permits without any guarantee as to
the absence of errors, the correctness and the relevance of the results or suitability for a specific application.
• You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for the regular
backup of programs and data and, if applicable, carry out the updates of the Software offered by Hilti on a regular basis. If you do not use the
AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the Software in each case by
carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or damaged data or programs,
arising from a culpable breach of duty by you.

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 44
www.hilti-me.com
GL 42 , TOP , BP THK 6 MM Profis Anchor 2.9.1
Company: Page: 1
Specifier: Project:
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 1/24/2021
E-Mail:

Specifier's comments:

1 Input data
Anchor type and diameter: HST2 M8 hmin1
Return period (service life in years): 50
Effective embedment depth: hef = 47 mm, hnom = 55 mm
Material:
Evaluation Service Report: ETA-15/0435
Issued I Valid: 12/21/2017 | -
Proof: Design method EN 1992-4, Mechanical
Stand-off installation: eb = 0 mm (no stand-off); t = 2 mm
Anchor plate: S 275; E = 210,000.00 N/mm2; fyk = 275.00 N/mm2; gMs = 1.000
lx x ly x t = 140 mm x 120 mm x 2 mm; (Recommended plate thickness: calculated (2 mm))
Profile: Rectangular hollow, ; (L x W x T) = 125 mm x 50 mm x 2 mm
Base material: uncracked concrete, C40/50, fc,cyl = 40.00 N/mm2; h = 250 mm, partial material safety factor gc = 1.500
Installation: hammer drilled hole, Installation condition: Dry
Reinforcement: no reinforcement or reinforcement spacing >= 150 mm (any Ø) or >= 100 mm (Ø <= 10 mm)
no longitudinal edge reinforcement

R
- The anchor calculation is based on a rigid anchor plate assumption.

Geometry [mm] & Loading [kN, kNm]

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 45
www.hilti-me.com Profis Anchor 2.9.1
Company: Page: 2
Specifier: Project:
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 1/24/2021
E-Mail:

2 Load case/Resulting anchor forces y

Load case: Design loads


2
Anchor reactions [kN]
Tension force: (+Tension, -Compression)
Anchor Tension force Shear force Shear force x Shear force y
1 0.000 3.275 3.275 0.000
x
2 0.000 3.275 3.275 0.000

max. concrete compressive strain: - [‰]


max. concrete compressive stress: - [N/mm2]
resulting tension force in (x/y)=(0/0): 0.000 [kN]
resulting compression force in (x/y)=(0/0): 0.000 [kN] 1

Anchor forces are calculated based on the assumption of a rigid anchor plate.

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 46
www.hilti-me.com Profis Anchor 2.9.1
Company: Page: 3
Specifier: Project:
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 1/24/2021
E-Mail:

3 Tension load (EN 1992-4, Section 7.2.1)


Load [kN] Capacity [kN] Utilization bN [%] Status
Steel Strength* N/A N/A N/A N/A
Pullout Strength* N/A N/A N/A N/A
Concrete Breakout Strength** N/A N/A N/A N/A
Splitting failure** N/A N/A N/A N/A
* anchor having the highest loading **anchor group (anchors in tension)

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 47
www.hilti-me.com Profis Anchor 2.9.1
Company: Page: 4
Specifier: Project:
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 1/24/2021
E-Mail:

4 Shear load (EN 1992-4, Section 7.2.2)


Load [kN] Capacity [kN] Utilization bV [%] Status
Steel Strength (without lever arm)* 3.275 9.120 36 OK
Steel failure (with lever arm)* N/A N/A N/A N/A
Pryout Strength** 6.549 48.689 14 OK
Concrete edge failure in direction x+** 6.549 12.884 51 OK
* anchor having the highest loading **anchor group (relevant anchors)

4.1 Steel Strength (without lever arm)


V0Rk,s [kN] k7 VRk,s [kN] gM,s VRd,s [kN] VEd [kN]
11.400 1.000 11.400 1.250 9.120 3.275

4.2 Pryout Strength


Ac,N [mm2] A0c,N [mm2] ccr,N [mm] scr,N [mm] fc,cyl [N/mm2] k8
32,456 19,881 71 141 40.00 2.000
ec1,V [mm] y ec1,N ec2,V [mm] y ec2,N y s,N y re,N y M,N
0 1.000 0 1.000 0.998 1.000 1.000
k1 N0Rk,c [kN] gM,c,p VRd,cp [kN] VEd [kN]
11.000 22.417 1.500 48.689 6.549
Group anchor ID
1, 2

4.3 Concrete edge failure in direction x+


lf [mm] dnom [mm] k9 a b fc,cyl [N/mm2]
47 8.0 2.400 0.082 0.065 40.00
c1 [mm] Ac,V [mm2] A0c,V [mm2]
70 31,500 22,050
y s,V y h,V y a,V ec,V [mm] y ec,V y re,V
1.000 1.000 1.000 0 1.000 1.000
V0Rk,c [kN] kT gM,c VRd,c [kN] VEd [kN]
13.528 1.0 1.500 12.884 6.549

5 Displacements (highest loaded anchor)


Short term loading:
NSk = 0.000 [kN] dN = 0.000 [mm]
VSk = 2.426 [kN] dV = 0.746 [mm]
dNV = 0.746 [mm]
Long term loading:
NSk = 0.000 [kN] dN = 0.000 [mm]
VSk = 2.426 [kN] dV = 1.157 [mm]
dNV = 1.157 [mm]

Comments: Tension displacements are valid with half of the required installation torque moment for uncracked concrete! Shear displacements are valid
without friction between the concrete and the anchor plate! The gap due to the drilled hole and clearance hole tolerances are not included in this
calculation!

The acceptable anchor displacements depend on the fastened construction and must be defined by the designer!

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 48
www.hilti-me.com Profis Anchor 2.9.1
Company: Page: 5
Specifier: Project:
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 1/24/2021
E-Mail:

6 Warnings
• The anchor design methods in PROFIS Anchor require rigid anchor plates per current regulations (ETAG 001/Annex C, EOTA TR029, etc.). This means load
re-distribution on the anchors due to elastic deformations of the anchor plate are not considered - the anchor plate is assumed to be sufficiently stiff, in
order not to be deformed when subjected to the design loading. PROFIS Anchor calculates the minimum required anchor plate thickness with FEM to
limit the stress of the anchor plate based on the assumptions explained above. The proof if the rigid anchor plate assumption is valid is not carried out by
PROFIS Anchor. Input data and results must be checked for agreement with the existing conditions and for plausibility!
• Checking the transfer of loads into the base material is required in accordance with EN 1992-4, Annex A!
• The design is only valid if the clearance hole in the fixture is not larger than the value given in Table 6.1 of EN 1992-4! For larger diameters of the
clearance hole see section 6.2.2 of EN 1992-4!
• The accessory list in this report is for the information of the user only. In any case, the instructions for use provided with the product have to be followed
to ensure a proper installation.
• For the determination of the Psi_re,v (concrete edge failure) a concrete cover of the edge reinforcement c = 30 mm is assumed
• The characteristic bond resistances depend on the return period (service life in years): 50

Fastening meets the design criteria!

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 49
www.hilti-me.com Profis Anchor 2.9.1
Company: Page: 6
Specifier: Project:
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 1/24/2021
E-Mail:

7 Installation data
Anchor plate, steel: S 275; E = 210,000.00 N/mm2; fyk = 275.00 N/mm Anchor type and diameter: HST2 M8 hmin1
Profile: Rectangular hollow, ; (L x W x T) = 125 mm x 50 mm x 2 mm Installation torque: 0.020 kNm
Hole diameter in the fixture: df = 9 mm Hole diameter in the base material: 8 mm
Plate thickness (input): 2 mm Hole depth in the base material: 70 mm
Recommended plate thickness: calculated (2 mm) Minimum thickness of the base material: 100 mm
Drilling method: Hammer drilled
Cleaning: Manual cleaning of the drilled hole according to instructions for use
is required.

7.1 Recommended accessories

Drilling Cleaning Setting


• Suitable Rotary Hammer • Manual blow-out pump • Torque wrench
• Properly sized drill bit • Hammer
y

70 70

15
2

60
90

x
60

1
15

70 70

Coordinates Anchor [mm]


Anchor x y c-x c+x c-y c+y
1 0 -45 - 70 - -
2 0 45 - 70 - -

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 50
www.hilti-me.com Profis Anchor 2.9.1
Company: Page: 7
Specifier: Project:
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 1/24/2021
E-Mail:

8 Remarks; Your Cooperation Duties


• Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles, formulas and
security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be strictly
complied with by the user. All figures contained therein are average figures, and therefore use-specific tests are to be conducted prior to using the
relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the data you put in. Therefore, you
bear the sole responsibility for the absence of errors, the completeness and the relevance of the data to be put in by you. Moreover, you bear sole
responsibility for having the results of the calculation checked and cleared by an expert, particularly with regard to compliance with applicable norms
and permits, prior to using them for your specific facility. The Software serves only as an aid to interpret norms and permits without any guarantee as to
the absence of errors, the correctness and the relevance of the results or suitability for a specific application.
• You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for the regular
backup of programs and data and, if applicable, carry out the updates of the Software offered by Hilti on a regular basis. If you do not use the
AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the Software in each case by
carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or damaged data or programs,
arising from a culpable breach of duty by you.

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 51
ADEQUACY OF GLASS THICKNESS

52
ADEQUACY OF GLASS THICKNESS
(AS PER ASTM E 1300 – 2002)

INTRODUCTION:

This report given structural calculation of glass thickness for


GL‐30 and rest of the Curtain Walls as this type is Critical as
per (ASTM E 1300 – 2002) according wind load calculations as
per 1.829 kpa. This analysis was done with the aid of software
SAFLEX programmer for determining of glass size and
thickness in conjunction with ASTM E 1300 code of practice,
Glass selection calculations ensuring the adequacy of glass
thickness so that not more than 8 glass units per thousand
breaks during the building life.

The typical Curtain Wall consists of 28 mm Double Glazed Vision Panel

Outer Frame: 6 mm Thick Tempered,

Air Space: 16 mm.

Inner Pane: 6 mm Thick Tempered.

53
The glass unit is supported on 2 nos. setting blocks as shown.

2550 mm (MAX)

P P

a a
322.5
L=1290
(Max)

Design wind load considered = 1.829 kpa

Simplified glass panel size = 1290 x 2550 mm

Deflection:
Maximum Allowable deflection = 12 mm
(From output window below)

54
Permissible deflection = (short side length) / 50, limited to 25 mm
= 1290 / 50, limited to 25 mm
= 25.8 mm, limited to 25 mm

= 25 mm > 16 mm (O.K.)

The glass thicknesses are sufficient to withstand design wind load.

55

You might also like