Ques.1. The main function of a fuse is to


1. Protect the line
2. Open the circuit
3. Prevent excessive currents
4. None of the above

Ques.2.Short-circuit currents are due to


1. Single phase to ground faults
2. Phase to phase faults
3. Three phase faults
4. Any of these

Ques.3.The relay with inverse time is


1. Directly proportional to the square of fault current
2. Direct proportional to the of fault current
3. Inversely proportional to the of fault current
4. Inversely proportional to the square of fault current

Ques.4.A relay is used to


a) Break the fault current
b) Sense the fault
c) Sense the fault and direct to trip the circuit breaker
d) All of these

Ques.5.Over current fault is most likely in


a) Transformer
b) Overhead line equipment
c) Alternator
d) Motors

Ques.6.Relay gets its operating energy from

a) Transformer
b) Alternator
c) Overhead lines
d) C.T., P.T.

Ques.7.Good relay should posses

a) Speed & reliability


b) Aped & sensitivity
c) Adequateness & selectivity
d) All of these

Ques.8.What is the purpose of back up protection?

a. To increase the speed


b. To increase the reach
c. To leave no blind spot
d. To guard against failure of primary

Ques.9.Function of auxiliary relay is as


(A) Change over relay
(B) Supervisory relay
(C) Tripping relay
(D) All of above

Ques.10.DTOC Relay stands for


1. Divide Time Over Current
2. Define Time Over Current
3. Definite Time Over Current
4. Differentiate time Over Current

Ques.11. A thermal protection switch can protect against


1. Short-circuit
2. Temperature
3. Overload
4. Overvoltage

Ques.12 Relays can be designed to respond to changes in


1. Resistance, reactance or impedance
2. Voltage and current
3. Temperature
4. All of the above

Ques.13 Overload relays are of type.


1. Solid state
2. Thermal
3. Electromagnetic
4. All of the above

Ques.14 Thermal overload relays are used to protect the motor against over current due to
1. Short-circuits
2. Heavy loads
3. Grounds.
4. All of the above

Ques.15. The function of the circuit breaker is


1. To safeguard the circuit
2. On and off the circuit
3. To save human life
4. None of these

Ques.16. In order that current should flow without causing excessive heating or voltage drop,
the
relay contacts should
1. Have low contact resistance
2. Be clean and smooth
3. Be of sufficient size and proper shape
4. Have all above properties

Ques.15.Directional relays are based on the flow of


1. Power
2. Current
3. Voltage Wave
4. None of the above

Ques.16.A differential relay measures the vector difference between


1. Two current
2. Two voltage
3. Two similar quantities
4. Any of the above

Ques.17.A transmission line is protected by


1. Time graded and current graded overcurrent protection
2. Distance Protection
3. Both 1 and 2
4. None of the above

Ques.18.Large internal faults are protected by


1. Merz price percentage differential protection
2. Mho and ohm relays
3. Horn gaps and temperature relays
4. Earth fault and positive sequence relays

Ques.19.When a transmission line is energized, the wave that propagates on it is


1. Current wave only
2. Voltage wave only
3. Both 1 and 2
4. Power factor wave only

Ques.20.Protective relays are devices that detect abnormal conditions in electrical circuits by
measuring
1. Current during abnormal condition
2. Voltage during abnormal condition
3. Constantly the electrical quantities which differ during normal and abnormal
conditions
4. None of the above

Ques.21.The voltage appearing across the contacts after the opening of the circuit breaker is
called voltage.
1. Recovery
2. Surge
3. Operating
4. Arc
Ques.22.A relay used on short transmission lines is
1. Reactance Relay
2. Mho’s Relay
3. Impedance Relay
4. None of these

Ques.23.The time interval which is passed in between the energization of the trip coil to the
instant of contact separation is called the
1. Opening Time
2. Closing Time
3. Delayed Time
4. None of the above
Ques.24.The rated voltage of the circuit breaker is
5. RMS Phase to Phase Voltage
6. Average Phase to Phase Voltage
7. RMS Ground to phase voltage
8. RMS Phase to Phase Voltage

Ques.25.Which relay operate fast in order to operating time?


a) Instantaneous relay
b) IDMT relay
c) Very inverse relay
d)Extremely inverse relay

Ques.26. Calculate Plug Setting Multiplier when relay is connected to a 400/5 current transformer
and set at 150% with primary fault current of 2400A.

a) 6
b) 5
c) 4
d) 3

Ques.27 The minimum relay coil current at which the relay operates is called .

a) PSM
b) Pick up value
c) relay value
d) RMS value

Ques.28. An Over current relay is used to ….


a) Break the Fault Current.
b) Sense the Fault.
c) Sense the Fault current & direct to trip the Circuit.
d) All of these.

Ques.29 Directional relays are based on the flow of ….

a) Power
b) Current
c) Voltage Wave
d) None

Ques.30.Current setting of relay for phase to phase faults can be from

a) 50 to 80 %
b)80 to 200 %
c) 50 to 100%
d) 50 to 200%

Ques.31 Determine the time of operation of 5 Amp, 3 Second, over-current relay having a current
setting of 125 % and time setting multiplier of 0.6 connected to supply circuit through a 400/5
current transformer when the circuit carries a fault current of 4000 A.

PSM 2 4 5 8 10 20
Operating 10 5 4 3 2.8 2.4
Time
a) 1.8 second
b) 2.1 second
c) 3.6 second
d )4.3 second

Ques.32.IDMT Relay stands for


1. Inverse Divide Minimum Time
2. Inverse Define Minimum Time
3. Inverse Definite Minimum Time
4. Inverse Differentiate Minimum time

Ques.33.For Time grading sytem type of relay is used.


a) Instantaneous relay
b) IDMT relay
c) Very inverse relay
d) DTOC relay
Ques.34. Plug setting of a relay can be changed by changing…

a) Airgap
b) Back-up Stop
c) Number of Ampere turns
d) All of these

Ques.35.H.R.C. fuses provide the best protection against


1. Overload
2. Reverse current
3. Open-circuits
4. Short-circuits

Ques.36.Which of the following is the least expensive protection for overcurrent is a low
voltage system?
1. Rewireable fuse
2. Isolator
3. Oil circuit breaker
4. Air break circuit breaker

Ques.37.In Railway applications circuit breaker is used.


1. SF6
2. Bulk oil
3. Minimum oil
4. Air Blast

Ques.38.MCB protects a circuit from


1. Short circuit
2. Over Load only
3. Both short circuit and overload
4. None of the above

Ques.39.IDMT Relay stands for


1. Inverse Divide Minimum Time
2. Inverse Define Minimum Time
3. Inverse Definite Minimum Time
4. Inverse Differentiate Minimum time
Ques.40.Wave trap is used to trap waves of
1. Power frequencies
2. Higher frequencies entering generator or transformer units
3. Lower frequencies entering generator or transformer units
4. Medium frequencies entering generator or transformer units

Ques.41.Discrimination between main and back up protection is provided by the use of


relays
1. Facts
2. Sensitive
3. Slow
4. None of the above

Ques.42.Induction cup relay is operated due to changes in


1. Current
2. Voltage
3. Both 1 & 2
4. None of the above

Ques.43.Short-circuit currents are due to


5. Single phase to ground faults
6. Phase to phase faults
7. Three phase faults
8. Any of these

Ques.44 Which of the following is used for the measurement of the insulation resistance?
1. Megger
2. Wattmeter
3. Ammeter
4. Voltmeter

Ques.45)i) Circle passing through origin of the graph is the charactristics of -


i) a)Impedance b)Reactance c)Mho d)Resistance

Ques.46) relay is most affected by arc resistance. a)Impedance b)Reactance


c)Mho d)Resistance
Ques.47) relay is used for protection of long transmission line. a)Impedance
b)Reactance c)Mho d)Resistance

Ques.48) relay has inherent Directional property. a)Impedance b)Reactance c)Mho


d)Resistance
Ques.49) relay is used for protection of Short transmission line. a)Impedance
b)Reactance c)Mho d)Resistance

Ques.50) relay is most affected by Power Swing. a)Impedance b)Reactance


c)Mho d)Resistance

Ques.51) In three stepped protection ,second step protects for


a)50 – 200%+50% of adjoining line b)10 -20% +50% of adjoining line
c)80 -90 % +80% of adjoining line d) 0 -120%+60% of adjoining line
Ques.52 Ref. to fig. if ON=6 UNIT and OA = 6.6, so percentage of line protected by Mho relay
is 90 %_

Ques.53) Ref. to fig. percentage of line protected by reactance relay is 100%.

Ques.54) In carrier current protection, wave trap is used is for trapping a) High
frequency waves entering in generating units
b) Power frequency waves
c) Both (a) and (b)
d) None of these
Ques55) Area occupied by relay is very large on R-X plane. - a)Impedance
b)Reactance c)Mho d)Resistance

Ques56) relay is most affected by power swing.


For i),ii),iii),iv) - a)Impedance b)Reactance c)Mho d)Resistance
Ques.57.A mho relay is used for protection of:
1. Protection of a transformer against external fault
2. Long Transmission Line
3. Protection of a transformer against all the internal faults and external fault
4. Medium Length lines

Ques.58.For which of the following protection from negative sequence currents is provided?
1. Generators
2. Motors
3. Transmission line
4. Transformers

Ques.59.A relay which measures impedance or a component of the impedance at the relay
location is known as
1. Induction Relay
2. Moving Coil Relay
3. IDMT Relay
4. Distance Relay

Ques.60.Distance relays are generally


1. Mho relays
2. Reactance relays
3. Impedance relays
4. All of the above

Ques 61.A Buchholz relay is used for


1. Protection of a transformer against all internal faults.
2. Protection of a transformer against external faults.
3. Protection of a transformer against both internal and external faults.
4. Protection of induction motors.

Ques62 .A three phase power transformer having a line voltage ratio of 400 V / 33 kV is
connected in star-delta. The C.T.s on 400 V side have current ratio as 1000/5. What must be
the C.T. ratio on 33 kV side.

20.12/5
65.32/5
4.5/5√3
12.12/5√3

Ques 63. The CTs of Star/Delta transformer is connected in

Star/Star
Star/Delta
Delta/Star
Delta /Delta

Ques64.In restricted earth fault protection, generally % of winding is protected.


100
95
85
75

Ques 65.A differential relay measures the vector difference between


5. Two current
6. Two voltage
7. Two similar quantities
8. Any of the above

Ques 66. Large internal faults are protected by


5. Merz price percentage differential protection
6. Mho and ohm relays
7. Horn gaps and temperature relays
8. Earth fault and positive sequence relays

Ques 67.In Bus bar protection the values of feeder current is 1000A,2000A and 3000A.The
value of CT Ratio will be
1000/1
2000/1
3000/1
5000/1

Ques 68.MCB protects a circuit from


5. Short circuit
6. Over Load only
7. Both short circuit and overload
8. None of the above

Ques 69.Wave trap is used to trap waves of


5. Power frequencies
6. Higher frequencies entering generator or transformer units
7. Lower frequencies entering generator or transformer units
8. Medium frequencies entering generator or transformer units
Ques 70. A generator is protected by restricted earth fault protection. The generator ratings
are 11 kV, 20 MVA. The relay setting is such that it trips for 1.5 out of balance. The
resistance to be added in the neutral to ground connection is 5 ohm. CT ratio is
1000/5.What percentage of winding protected against phase to ground fault.
76 %
50%
68%
70%

Ques.71.The under voltage relay can be used for


1. Generators
2. Busbars
3. Motors
4. All of the above

Ques.72.The relay with inverse time is


5. Directly proportional to the square of fault current
6. Direct proportional to the of fault current
7. Inversely proportional to the of fault current
8. Inversely proportional to the square of fault current

Ques.73.When the fault current is 2000 A, for a relay setting of 50% with CT ratio 500/5,
the plug setting multiplier will be
1. 16
2. 12
3. 4
4. 8

Ques.74.Which of the following circuit breakers has high reliability and minimum
maintenance?
1. Air blast circuit breakers
2. Circuit breaker with SF6 gas
3. Vacuum circuit breakers
4. Oil circuit breakers

Ques.75.Arc in a circuit breaker is interrupted at


1. Zero current
2. Maximum current
3. Minimum current
4. Maximum voltage

Ques.76.A Buchholz relay is used for


1. Protection of a transformer against all internal faults.
2. Protection of a transformer against external faults.
3. Protection of a transformer against both internal and external faults.
4. Protection of induction motors.

Ques.77.Admittance relay is relay.


1. Impedance
2. Distance
3. Non-directional
4. None of the above

Ques.78.If the fault occurs near the impedance relay, the VI ratio will be
1. Constant for all distances
2. Lower than that of if the fault occurs away from the relay
3. Higher than that of if the fault occurs away from the relay
4. None of the above

Ques.79.The following statement is associated with the Buchholz relay is not true
1. It is a gas actuated device
2. It is a current operative device
3. It is placed between the transformer tank and the conservator
4. It causes alarm for minor fault and tripping for major fault

Ques.80.In which of the following equipment, current rating is not necessary?


1. Circuit breaker
2. Relay
3. Isolator
4. Load break switch

Ques.81.A single phasing relay can be used with

a) 1ɸ motor
b) 2r ɸ motor
c) 3 ɸ motor
d) All of these

Ques.82.A relay is used to

a) Break the fault current


b) Sense the fault
c) Sense the fault and direct to trip the circuit breaker
d) All of these

Ques.83. In impedance relay, current element torque should be


Equal to voltage element torque
b) Greater than voltage element torque
c) Less than voltage element torque
d) None of these

Ques84.Over current fault is most likely in


a) Transformer
b) Overhead line equipment
c) Alternator
d) Motors

Ques.85.Plug setting of a relay can be changed by changing

a) Air gap
b) Back up stop
c) Number of ampere turns
d) All of these

Ques.86.Instantaneous relay should operate within


a) 0.0001 sec
b) 0.001 sec
c) 0.01 sec
d) 0.1 sec

Ques.87.MHO relay is inherently a


a) Directional type
b) Non-directional type
c) Unidirectional type
d) None of these

Ques.88.Relay gets its operating energy from

a) Transformer
b) Alternator
c) Overhead lines
d) C.T., P.T.

Ques.89.Good relay should posses

a) Speed & reliability


b) Aped & sensitivity
c) Adequateness & selectivity
d) All of these

Ques.90.Relays for transmission line protection are

a) In three zones
b) In two zones
c) Independent of zone
d) None of these

Ques.91.What is the purpose of back up protection?

a. To increase the speed


b. To increase the reach
c. To leave no blind spot
d. To guard against failure of primary

Ques.92.What is the actuating quantity for the relays?

a. Magnitude
b. Frequency
c. Phase angle
d. All of these

Ques.93For the protection of a very long extra high-voltage lines, the productive relay used is

A. Over currently with extremely inverse characteristics


B. Percentage differential relay
C. Reactance type distance relay
D. Mho type distance relay

Ques.94.Burden of a protective relay is the power

A. Required to operate the circuit breaker


B. Absorbed by the circuit of relay
C. Developed by the relay circuit
D. None of the above

Ques.95.Function of auxiliary relay is as


(A) Change over relay
(B) Supervisory relay
(C) Tripping relay
(D) All of above

Ques.96.Which relay used mercury?


(A) Thermal relay
(B) Gas operated relay
(C) Induction cup relay
(D) None of above

Ques.97.In inverse characteristic of relay as current increase operation time will be


(A) Increase
(B) Decrease
(C) Remain same
(D) None of above

Ques.98.Which is not an advantage of static relay?


(A) Fast speed
(B) Less maintenance
(C) Less burden
(D) Less Price

Ques.99.Location of buchholz relay is


(A) In main tank
(B) In conservation tank
(C) Between main and conservation tank
(D) None of above

Ques.100.If rated secondary current of CT is 5A and tapping is at 150% then peak up current
is
(A) 5A
(B) 7.5A
(C) 10A
(D) 2.5A

Ques.101.If fault current is 30A and peak up current is 7.5A then PSM is
(A) 4
(B) 5
(C) 6
(D) 7.5

Ques.102.If PSM is 5 and peak up current is 7A then fault current is


(A) 30A
(B) 35A
(C) 7.5A
(D) 5A

Ques.103.DTOC Relay stands for


5. Divide Time Over Current
6. Define Time Over Current
7. Definite Time Over Current
8. Differentiate time Over Current

Ques.104.Spill Current is

(A) I1/I2
(B) I1-I2
(C) I1+I2
(D) I1*I2

Ques.105. In a circuit breaker the basic problem is to

A. Maintain the arc


B. Extinguish the arc
C. Transmit large power
D. Emit the ionizing electrons
Ques.106The arcing contacts in a circuit breaker are made of
1. Copper tungsten alloy
2. Porcelain
3. Electrolytic copper
4. Aluminum alloy

Ques.107. Which of the following medium is employed for the extinction of arc in air circuit
breaker?
1. Water
2. Oil
3. Air
4. SF6

Ques.108 The function of the circuit breaker is


5. To safeguard the circuit
6. On and off the circuit
7. To save human life
8. None of these

Ques.109Circuit breakers are essentially


1. Current carrying contacts called electrodes
2. Arc extinguishers
3. Circuits to break the system
4. Transformers to isolate the two systems

Ques.110.Air blast circuit breaker is used for


1. Overcurrents
2. Short duty
3. Intermittent duty
4. Repeated duty
Ques.111.The rated voltage of the circuit breaker is
1. RMS Phase to Phase Voltage
2. Average Phase to Phase Voltage
3. RMS Ground to phase voltage
4. RMS Phase to Phase Voltage

Ques.112.The time interval which is passed in between the energization of the trip coil to the
instant of contact separation is called the
9. Opening Time
10. Closing Time
11. Delayed Time
12. None of the above

Ques.113.Arc in a circuit breaker is interrupted at


5. Zero current
6. Maximum current
7. Minimum current
8. Maximum voltage

Ques.114.Which of the following circuit breakers has high reliability and minimum
maintenance?
5. Air blast circuit breakers
6. Circuit breaker with SF6 gas
7. Vacuum circuit breakers
8. Oil circuit breakers

Ques.115 Interrupting a low inductive current may lead to


a) Very high restriking voltage
b) Very high current
c) Rupture of circuit breaker
d) Current chopping

Ques.116 Current chopping can be avoided by

a) Resistance switching
b) Inductive switching
c) Capacitive switching
d) Diode switching

Ques.117. The making capacity of a circuit breaker is

a). Less than the asymmetrical breaking capacity of the breaker


b). Greater than the asymmetrical breaking capacity of the breaker
c). Equal to the symmetrical breaking capacity of the breaker
d). Equal to the asymmetrical breaking capacity
Ques.118 Which one of the following types of circuit breaker is used for high power high
voltage
a) Oil circuit breaker
b) Air blast circuit breaker
c) SF6 circuit breaker
d) Vacuum circuit breaker

Ques.119. Which one of the following statements is NOT true for circuit breaker?

a) It can switch on or off the circuit manually in the healthy condition


b) It can switch on or off the circuit by remote control in the healthy condition.
c) It breaks the circuit automatically in the faulty condition
d) It does not switch on the circuit in the faulty condition

Ques.120. Which one of the following is NOT used as quenching medium in circuit breaker?
a) Oil
b) Carbon dioxide
c) sulphur hexafluoride
d) Air blast

Ques.121 In minimum oil circuit breaker, the oil is used for

a) arc quenching
b) insulation
c) cooling
d) None of these

Ques.122. A circuit breaker is rated as 1500A, 1000 MVA, 33 KV,3 second , find – 1) rated
symmetrical breaking current.

a) 21000A
b) 44614 A
c) 1500 A
d) 17496 A

Ques.123 Refering above Question-rated making current is


a) 21000A
b) 44614 A
c) 1500 A
d) 17496 A

Ques.124 The rating of a circuit breaker is generally determined on the basis of

a). Line-to-line fault current


b). Symmetrical fault current
c). Single line to ground fault current
d). Double line to ground fault current

Ques.125 In air blast circuit breaker resistance switching is used to

a). Read use the magnitude of the fault current


b). Control the CB operating time0
c). Damp out the fast transient
d). Change the fault current power factor
Ques.126 In a system of 132 kV, the line to ground capacitance is 0.01 micro F & the
inductance is 5 henries. Determine the voltage appearing across the pole of CB, if a
magnetizing current of 5 amps (instantaneous value) is interrupted.
a) 111.8 KV
b) 115.6 KV
c) 110.3 KV
d) 19.98 KV

Ques.127. If the restriking voltage increases more rapidly than the dielectric strength, then the
arc ---

a) extinguishes
b) persists
c) both a) and b)
d) None of the these

Ques.128. If the rate of heat removal is faster than rate of heat generation, this is ---

a) Cassies Theory
b) Slepains Theory
c) Recovery rate theory
d) None of the these

Ques.129. The phenomenon of arc interruption before natural zero is called----.

a) Current Chopping
b) Resistance Switching
c) Capacitive current Interruption
d) Circuit Breaking

Ques.130. Which of the following medium is employed for the extinction of arc in air circuit
breaker?
1. Water
2. Oil
3. Air
4. SF6

Ques.131.Making capacity of Circuit Breaker is ----- --.

a) 2.55 x symmetrical breaking capacity


b) 1.8 x symmetrical breaking capacity
c) 3 x symmetrical breaking capacity
d) 1.6 x symmetrical breaking capacity

Ques.132. Natural frequency of oscillation is given by -------

1
a) 1/ (2 π √LC) 2 LC
b) 1/(2 π √L/C)
c) 1/(2 π √1/LC – 1/4R2C2 )
d) 0.5√(L/C)

Ques.133 For a 132 KV system, the reactance and capacitance upto the location of C.B. is 3
Ω and 0.015 μF respectively. Calculate – i)Frequency of transient Oscillation

a) 11.2KHz
b) 13.2 KHz
c) 6.31 KHz
d) 9.5 KHz
Ques.134.Refering above Question , ii)Maximum value of restriking voltage

a) 132 KV
b) 9 KV
c) 215.5 KV
d)17.92KV

Ques.135. SF6 gas


1. Is yellow in color
2. Is lighter than air
3. Is nontoxic
4. Has pungent small

Ques.136.The arcing contacts in a circuit breaker are made of


5. Copper tungsten alloy
6. Porcelain
7. Electrolytic copper
8. Aluminum alloy

Ques.137 Which of the following medium is employed for the extinction of arc in air circuit
breaker?
5. Water
6. Oil
7. Air
8. SF6
Ques.138.Circuit breakers are essentially
5. Current carrying contacts called electrodes
6. Arc extinguishers
7. Circuits to break the system
8. Transformers to isolate the two systems

Ques.139.Air blast circuit breaker is used for


5. Overcurrents
6. Short duty
7. Intermittent duty
8. Repeated duty
Ques.140 Circuit breakers are essentially

9. Current carrying contacts called electrodes


10. Arc extinguishers
11. Circuits to break the system
12. Transformers to isolate the two systems

Ques.141 Current chopping can be avoided by

Resistance switching
Inductive switching
Capacitive switching
Diode switching

Ques.142 In Bulk oil circuit breaker, the oil is used for

A. arc quenching
B. insulation
C. cooling
D. insulation and cooling

Ques.143 A circuit breaker is rated as 1250A, 200 MVA, 33 KV, 4 second , find –
rated symmetrical breaking current. = 1000*106/sqrt3*33*103 =

Hint-- breaking cap in MVA/Sqrt 3*rated Voltage

A. 21000A

B. 44614 A

C. 1500 A

D.17496 A

Ques.144 A circuit breaker is rated as 1500A, 1000 MVA, 33 KV,3 second , find -
rated making current is

A. 21000A

B. 44614 A= 2.55* symmetrical breaking capacity


C. 1500 A

D. 17496 A

Ques.145 In a system of 132 kV, the line to ground capacitance is 0.01 micro F & the
inductance is 5 henries. Determine the voltage appearing across the pole of
CB, if a magnetizing current of 5 amps (instantaneous value) is interrupted.

A. 111.8 KV

B. 115.6 KV e=I *sqrt(L/C)

C. 110.3 KV

D. 19.98 KV

Ques.146 If the rate of heat removal is faster than rate of heat generation, this is ---

A. Cassies Theory

B. Slepains Theory

C. Recovery rate theory

D. None of the these

Ques.147 Making capacity of Circuit Breaker is ----- --.

A. 2.55 x symmetrical breaking capacity


B. 1.8 x symmetrical breaking capacity

C. 3 x symmetrical breaking capacity

D. 1.6 x symmetrical breaking capacity

Ques.148 For a 132 KV system, the reactance and capacitance upto the location of
C.B. is 3 ohm and 0.015 µF respectively. Calculate – Maximum value of
restriking voltage

A. A.132 KV
B. 9 KV Epeak=[132*103/sqrt 3]*sqrt2=107.77Kv
C. 215.5 KV Maximum value of restriking voltage=2* Epeak
=215.5kv
D. 17.92 KV
Ques.149 The RMS Voltage that appears across the contacts of circuit breaker after
final arc extinction is called
E. arc voltage
F. restriking voltage
G. recovery voltage
H. RRRV

Ques.150.Overcurrent protection is used for _ a)Transformer b)


Incipient Fault c) Transmission Line d)Bus bar