You are on page 1of 2

KB1250 12V 5.

0Ah
The KB Standard series consists in VRLA batteries - AGM technology (Absorbent Glass
Mat), with a design life of 3-5 years and it is designed for general applications such
as UPS, telecommunications and electrical applications.

Dimensions and Terminal (Unit: mm (inches))

F187/F250

101
97
Terminal

70

Performance Characteristics

90
Nominal Voltage 12V
Dimensions Length (mm / inch) 90±1 / 3.54
Width (mm / inch) 70±1 / 2.76 Applications
Height (mm / inch) 97±1 / 3.82
Total Height (mm / inch) 101±1 / 3.98 Alarm systems Marine equipment
Approx Weight (Kg / lbs) 1.58 / 3.48 Cable television Medical equipment
Design Life 5 years Communications Equipment Micro processor based office machines
Terminal F1 / F2 Control Equipment Portable cine & Video lights
Container Material ABS Computers Solar powered systems
Rated Capacity 5.00Ah / 0.250A (20hr, 1.75V / cell, 25ºC / 77ºF)
Electronic Cash Registers Telecommunications systems
3.90Ah / 1.30A (3hr, 1.75V / cell, 25ºC / 77ºF)
(1hr, 1.60V / cell, 25ºC / 77ºF)
Electric Test Equipment Television & Video recorders
3.30Ah / 3.30A
Emergency lighting systems Toys
Max. Discharge Current 75A (5s) Fire & Security Uninterruptible power supply systems
Internal Resistance Approx 40mΩ
Geophysical equipment Vending machines
Operating Temp. Range Discharge : -20 ~ 50ºC (-4 ~122ºF)
Charge : -20 ~ 50ºC (-4 ~ 122ºF)
Storage : -20 ~ 50ºC (-4 ~ 122ºF) Certifications
Max.1.25A
Cycle Use Voltage: 14.4V ~ 15.0V at 25ºC (77ºF)
Temp. Coefficient: -30mV/ºC
ISO 9001:2008 ISO 14001:2008
Standby Use Voltage: 13.5V ~ 13.8V at 25ºC (77ºF)
Temp. Coefficient: -18mV/ºC
Capacity affected by Temperature 40ºC (104ºF) 103%
Discharge Current vs. Discharge Voltage
25ºC (77ºF) 100%
0ºC (32ºF) 86%
Self Discharge Fully charged Kaise Standard Series batteries may be Final discharge 1,8 1,75 1,7 1,6
stored for up to 6 months at 25ºC (77ºF) and then a voltage V/CELL
freshening charge is required. For higher temperatures the
time interval will be shorter.
Discharge current I ≤ 0,1CA 0.25CA ≥ I >>0.1CA 0.55CA ≥ I> > 0.25CA I > 0.55CA
(A)

Discharge Constant Current (Amperes) at 25ºC (77ºF) Discharge Constant Power (Watts per cell) at 25ºC (77ºF)

Volts/cell 5min 10min 15min 30min 1h 3h 5h 10h 20h Volts/cell 5min 10min 15min 30min 1h 3h 5h 10h 20h
1.80V 13.8 10.5 7.15 5.50 2.80 1.23 0.835 0.460 0.240 1.80V 25.5 20.1 14.6 10.4 5.28 2.39 1.62 0.893 0.493
1.75V 15.0 11.1 7.70 5.69 2.90 1.30 0.870 0.470 0.250 1.75V 28.4 20.8 15.3 10.5 5.36 2.46 1.66 0.912 0.496
1.70V 16.1 11.7 8.25 5.82 3.00 1.32 0.910 0.480 0.255 1.70V 31.3 21.4 15.8 10.6 5.52 2.49 1.69 0.933 0.507
1.65V 19.7 12.4 8.85 6.01 3.10 1.34 0.920 0.490 0.260 1.65V 34.3 22.1 16.6 10.6 5.69 2.53 1.74 0.941 0.511
1.60V 19.8 13.0 9.65 6.33 3.30 1.38 0.940 0.495 0.265 1.60V 37.2 23.3 17.7 10.7 6.05 2.61 1.78 0.959 0.525

(Note) The above characteristics data are average values obtained within
three charge/discharge cycles not the mimimum values.
KB1250 12V 5.0Ah

Charging Characteristics Discharge characteristic


capacity

Charge

Chrage
voltage
Charge

current

13.0

Discharge voltage(V)
Constant charge at 0.1CA-14.1V(25℃)
( %) (CA) (V)
12.0
120 14.5 Charge voltage

14.0 11.0
100
Charge capacity
13.5
0.6C 0.4C 0.2C 0.1C 0.05C
80 0.10 13.0 10.0

0.08 12.5 3C 2C 1C
60 9.00
12.0
0.06 100% DOD
40 11.5 50% DOD 8.00
0.04
11.0
20 0.02 7.00
10.5 Charge current
1 2 4 6 8 10 20 40 60 2 4 6 8 10 20
0 0 10.0 hour
min
0 4 8 12 16 20 24 Discharge time
Time(hour)

Temperature Effects in Relation to Battery Capacity The effect of discharge depth on cycle life

120 120

100 100
Capacity(%)
Capacity(%)

80 80

60 60
100%DOD 50%DOD 30%DOD
40 40

20 20

0 0
-20 -10 0 10 20 30 40 50 0 200 400 600 800 1000 1200 1400
Ambient temperature(℃) Number of cycles

Curves of self-discharge The effect of temperature on float life

100
7.5
90
6.0
Capacity(%)

80
Life(year)

0℃

70 20℃ 10℃ 4.5

40℃ 30℃
60 3.0

50
1.5
40
0 3 6 9 12 15 18 0
10 20 30 40 50 60
Storage time(months)
Ambient temperature(℃)

IMPORTANT NOTE: The specifications presented herein are subject to revision without notice.

Contacto
energy@tempelgroup.com
PANASONIC EVOLTA EL FUTURO DE LAS PILAS
www.tempelgroup.com
Tempel Group en el mundo
BARCELONA · MADRID · VALENCIA · BILBAO · SEVILLA · LISBOA · PORTO · BUENOS AIRES · LIMA
BARCELONA
SANTIAGO DE CHILE· ·MADRID
BOGOTÁ ·· SÃO
VALENCIA
PAULO ·· MÉXICO
BILBAODF ·· CIUDAD
SEVILLADE PANAMÁ
· LISBOA · PORTO · QUITO
· MONTEVIDEO
www.tempelgroup.com
BUENOS AIRES · SANTIAGO DE CHILE · BOGOTÁ · SÃO PAULO · LIMA · MEXICO DF

You might also like