You are on page 1of 2

DESIGN OF ANCHORS AND BASE PLATE

JACK BEAM TO COLUMN


For Compression
Fy = 412.5 Kn
Fx = 5 Kn
Fz = 5 Kn

For Uplift
Fy = 255 Kn
Fx = 5 Kn
Fz = 5 Kn

For Compression Case


Try, M 24 Bolts, Numbers = 4
Shear Fx/Bolt = 5 4
= 1.25 Kn
Shear FZ/Bolt = 5 4
= 1.25 Kn
Resultant Shear = Sqrt [1.25²+1.25²]
= 1.77 Kn
Shear Capacity Of, M 24 Bolts > 56.5 Kn OK
(Grade 4.6)
For Up lift CaseCase
Try, M 24 Bolts, Numbers = 4
Tension Fy/Bolt = 255 4
= 63.8 Kn
TensionCapacity Of, M 24 Bolts > 67.8 Kn OK
(Grade 4.6)
Shear Fx/Bolt = 5 4
= 1.25 Kn
Shear FZ/Bolt = 5 4
= 1.25 Kn
Resultant Shear = Sqrt [1.25²+1.25²]
= 1.77 Kn
Shear Capacity Of, M 24 Bolts > 56.5 Kn OK
(Grade 4.6)
Combined Tension & shear = T / 47 + V / 39.2
= 0.97
< 1.4 OK
DESIGN OF ANCHORS AND BASE PLATE

Check Base Plate Thickness

Maximum Bolt Tension = 63.75 Kn


Maximum Projection of Plates = 60 mm
Moment, M = 63.75 * 60/1000
= 3.83 Kn-m
Modulus required, Z = Mx10^6 / ( 1.35 x 265 )
= 12028.30 mm³
1 /6 x b x t² = Z
b-moment resisting width
1/6 x 90 x t² = 12028.30
t = 28.32
Provided, base Plate Thickness < 30.00 mm OK

Anchor Bolt and length


fb = design stress = 0.28 Sqrt (Fcu) = 0.28 * Sqrt ( 35 )
fb = 1.66 N/mm²
Bolt Tension T = 63.75 Kn
Used Bolt Dia, d = 24 mm
Length of Anchor (L)
T x 1000 / (3.14 x 20 x fb) = 511 mm
Provided < 550 mm OK