▪ Certificate of Analysis ▪
Product: WatR™ Pollution PCBs in Oil
Catalog Number: 729S
Lot No. P297-729S Product use instructions are included as part of
the certification packet and are paginated
Certificate Issue Date: December 16, 2019 separately from this Certificate of Analysis. Please
reference the product use instructions for catalog
Expiration Date: August 22, 2022 #729S revision 090119.
Revision Number: Original
CERTIFICATION
Certified QC Performance PT Performance
Parameter Value¹ Uncertainty² Acceptance Limits³ Acceptance Limits⁴
mg/kg % mg/kg mg/kg
ANALYTICAL VERIFICATION
Certified
Parameter Value¹ Proficiency Testing Study NIST Traceability
Mean Recovery⁵ n SRM Number⁶ Recovery
mg/kg mg/kg % %
Aroclor 1016 <0.860 - - - - -
Aroclor 1221 <1.25 - - - - -
Aroclor 1232 <1.25 - - - - -
Aroclor 1242 30.9 25.9 83.7 32 3077 107
Aroclor 1248 <1.25 - - - - -
Aroclor 1254 <0.860 - - - - -
Aroclor 1260 <0.860 - - - - -
▪ Certificate of Analysis ▪
1. The Certified Values are the actual gravimetric/volumetric "made-to" concentrations confirmed by ERA analytical verification. The certified values are
monitored and purchasers will be notified of any significant changes resulting in recertification or withdrawal of this certified reference material during the
period of validity of this certificate.
2. The Uncertainty represents an expanded uncertainty and approximates a 95% confidence interval. The uncertainty is based on the characterization,
homogeneity and stability characteristics of the product, multiplied by a coverage factor (k=2). The uncertainty applies to the product as supplied and does
not take into account any required or optional dilution and/or preparations the laboratory may perform while using this product. The formula used to calculate
the expanded uncertainty is:
Uexpanded = k * SQRT((Uchar²) + (Uhomogen²) + (ULTS²) + (USTS²) + (URSS²))
Where:
If you have any questions or need technical assistance, please call ERA technical assistance
at 1-800-372-0122 or send an email to info@eraqc.com.
Description:
• This standard is packaged in a 10 mL flame-sealed ampule containing approximately 5 grams of standard.
• The standard is not preserved.
• The solvent for this standard is transformer oil.
• The standard can be stored at room temperature.
• This product is intended to be used as a quality control check of the entire analytical process for the
analytes/matrix included in the standard.
• The dilution instructions below represent the minimum suggested sample size for this product. Using a
smaller sample size may invalidate the assigned value and/or uncertainty shown on the certificate of analysis.
• The certified values apply to the diluted sample after following the stated dilution instructions.
Helpful Hints:
• This standard has been prepared as a whole volume standard and is ready to analyze as received.
• This standard should be analyzed as soon as possible after the concentrate is diluted.
• The dilution scheme given below is simply a suggestion and you may use other dilutions as you require.
Instructions:
1. Carefully snap the top off of the PCBs in Oil ampule.
2. Tare a clean, dry 10 mL class A volumetric flask.
3. Transfer approximately 1.0 g of the PCBs in Oil standard to the flask and record the weight.
4. Dilute the flask to the line with pesticide grade hexane and mix well.
5. Cap the flask and mix by inverting two or three times.
6. Immediately analyze the diluted sample by your normal procedures.
Safety:
ERA products may be hazardous and are intended for use by professional laboratory personnel trained in the
competent handling of such materials. Responsibility for the safe use of these products rests entirely with the
buyer and/or user. Safety Data Sheets (SDS) for all ERA products are available through our website
www.eraqc.com.