This document is an inspection report for the residual unbalance of a compressor rotor from PT Sulzer Hickham Indonesia. It provides measurements taken at 6 phases for the rotor, with residual unbalance found to be 15.31 gr-mm, within the allowable tolerance of 134 gr-mm. The rotor has a maximum continuous speed of 10395 RPM and was statically weighed at 220 kg. Inspections were performed by Yudo on July 26, 2007.
This document is an inspection report for the residual unbalance of a compressor rotor from PT Sulzer Hickham Indonesia. It provides measurements taken at 6 phases for the rotor, with residual unbalance found to be 15.31 gr-mm, within the allowable tolerance of 134 gr-mm. The rotor has a maximum continuous speed of 10395 RPM and was statically weighed at 220 kg. Inspections were performed by Yudo on July 26, 2007.
This document is an inspection report for the residual unbalance of a compressor rotor from PT Sulzer Hickham Indonesia. It provides measurements taken at 6 phases for the rotor, with residual unbalance found to be 15.31 gr-mm, within the allowable tolerance of 134 gr-mm. The rotor has a maximum continuous speed of 10395 RPM and was statically weighed at 220 kg. Inspections were performed by Yudo on July 26, 2007.