You are on page 1of 475

BILL NO.

0
SUMMARY

TA2459 Lesaffre Garuda 1/3 02ba-4c3f-3a4b-1dc6-Cover


Item BILL NO. 0 SUMMARY RUPIAHS
No. SUMMARY

SUMMARY

BILL 01 PRELIMINARIES -

BILL 02 PARKIR AREAN AND EXTERNAL WORKS -

BILL 14 COOLING TOWER -

BILL 21 ELECTRICAL SUBSTATION -

BILL 31 MOLASSES STORAGE -

BILL 40 YEAST CREAM PRODUCTION -

BILL 50 INSTANT DRY YEAST AND COMPRESS YEAST -

BILL 77 VINASSES STORAGE -

BILL 92 MAINTENANCE AND UTILITIES -

BILL 94 GUARD HOUSE -

BILL 95 FIRE PUMP HOUSE -

BILL 96 ADMINISTRATION BUILDING -

BILL 97 CANTEEN AND MUSHOLLA -

BILL 99 PIPE BRIDGE -

BILL NO. 0

TA2459 Lesaffre Garuda 2/3 02ba-4c3f-3a4b-1dc6-Sum


CARRIED TO SUMMARY -

TA2459 Lesaffre Garuda 3/3 02ba-4c3f-3a4b-1dc6-Sum


BILL NO. 01
PRELIMINARIES

TA2459 Lesaffre Garuda 1/3 133c-5d46-19bc-cd13


Item BILL NO. 01
1.1 PRELIMINARIES Qty Unit Rate Rupiahs
No. PRELIMINARIES

REFERENCE : TENDER DOCUMENTS SECTION III.4


PRELIMINARIES REQUIREMENTS

A Permit and Fees 1 LS -

B General Requirements
B.1 Bonds, Guarantees and Securities 1 LS -
B.2 Insurances (CAR, TPL, BPJS) 1 LS -
B.3 Site Management and Establishment Costs 1 LS -
B.4 Contractor's equipment 1 LS -
B.5 Contractor's Labour 1 LS -
B.6 Contractor's Employees 1 LS -
B.7 Workmen Living 1 LS -
B.8 Visitors 1 LS -
B.9 Identification Badges 1 LS -
B.10 Safeguarding the Works 1 LS -
Maintenance and Protection of Existing Roads, Bridges Footpaths,
B.11 1 LS -
Fences, Rivers and Irrigation Channels
B.12 Protection of Public and Private Services 1 LS -
B.13 Contractor's Responsibilities Towards Neighbours 1 LS -
B.14 Noise Control on the Site 1 LS -
B.15 Removal of Rubbish 1 LS -
B.16 Temporary Diversion of Traffic 1 LS -
B.17 Project Signage 1 LS -
B.18 Certification and guarantees 1 LS -
C.19 Rapid Test for Worker (as Per local regulation) 1 LS

C Temporary Works
C.1 Contractor's Storages 1 LS -
C.2 Contractor's Site Office 1 LS -
C.3 Site Accomodation for Security Staff 1 LS -
C.4 Telephone and Internet Connections (for contractor own use) 1 LS -
C.5 Water 1 LS -
C.6 Lighting and Power 1 LS -
C.7 Fire Protection 1 LS -
C.8 Temporary Lightning Protection 1 LS -
C.9 Cleaning Up 1 LS -

1.1 PRELIMINARIES
CARRIED OUT TO COLLECTION BILL NO. 01 Rp. -

TA2459 Lesaffre Garuda 2/3 133c-5d46-19bc-cd13


Item BILL NO. 01
1.1 PRELIMINARIES Qty Unit Rate Rupiahs
No. PRELIMINARIES

D Administration & Quality


D.1 Project Meetings 1 LS -
D.2 Progress report and Progress Photographs 1 LS -
D.3 Contractor's Calculation and Shop Drawings 1 LS -
D.4 As-Built Drawings 1 LS -

E Safety, Health and Welfare of Work People 1 LS -

F Builders Work in Connection Direct Contractors: 1 LS -

The Main Contractor shall be responsible for complete coordination of


the works to other contractor, Equipment vendor and Furniture installation

The main contractor shall allow for forming all chases, recesses, holes and
penetration through concrete work brickwork/blockwork for the works of
the Direct Contractor

The main contractor shall allow for building or casting in all pipes, pipe
sleeves, anchors, brackets and the like sundry items supplied by the Direct
Contractors into concrete, reinforced and masonry

Core drilling for pipe/sleeve penetrations to "wet" areas (areas with liquid
applied or itegral waterproofing) including sealing between pipe and
concrete slab with non shrink grout with epoxy caulking

Conctractor should be responsible for all manhole, at ceiling all wall for
MEP works

Rp. -

Collection

Page Bill 1.1 / 1 -

Page Bill 1.1 / 2 -

1.1 PRELIMINARIES
CARRIED TO SUMMARY AT END OF BILL NO. 01 Rp. -

TA2459 Lesaffre Garuda 3/3 133c-5d46-19bc-cd13


BILL NO. 02
PARKING AND EXTERNAL WORKS

TA2459 Lesaffre Garuda 1/27 b3ba-e2a2-55be-93fa-Cover


Item BILL NO. 02 SUMMARY Credensa
No. PARKING AND EXTERNAL WORKS

SUMMARY

02.1 DEMOLITION N/A

02.2 EARTHWORK -

02.3 CONCRETE -

02.4 MASONRY -

02.5 METALS -

02.7 THERMAL AND MOISTURE PROTECTION N/A

02.8 DOORS AND WINDOWS N/A

02.9. FINISHES -

02.10 SPECIALITIES N/A

02.11 MECHANICAL WORKS -

02.12 ELECTRICAL WORKS -

02.3 HVAC WORKS N/A

BILL NO. 02
CARRIED TO SUMMARY -

TA2459 Lesaffre Garuda 2/27 b3ba-e2a2-55be-93fa-Sum


Item BILL NO. 02 Qty Unit Rate Rupiahs
PARKING AND EXTERNAL 02.2 EARTHWORK
No.
WORKS

02.2.1 EARTHWORK

The Contractor is to allow in his rates for earthwork for bulking/shrinkage


factors he consider appropriate and entirely at his own risk

The excavation is measured based on the existing ground level

Excavation, Compacted Backfill, and Disposal in any material including


rock or hard material, working space 500mm at perimeter items as defined;
Excavating, starting from stripped level, trenches to receive depth as
specified
A To External area m3

02.2.2 BASE COURSES

Compacted of subgrade to 95% Standard Proctor Density as specified

B To External area m2

Compacted sandfill 100mm thick as specified

C To Concrete road m2

D To Paving Block (HD, LD, and Pathway) m2

E To Control Box m2

F To Drainage

G To ME Foundation, Cable Duct, and Sleeve m2

H To Absorption pit m2

I To Retention pit m2

Crushed stone 1-10mm as specified

J To Concrete road m2

K To Paving Block LD m2

L To Paving Block HD m2

M To ME Cable Duct m2

Macadam stone 5-250mm (gravel) as specified

N To Concrete road m2

O To Paving Block LD m2

P To Paving Block HD m2

Q To Absorption pit m2

TA2459 Lesaffre Garuda 3/27 b3ba-e2a2-55be-93fa-.2


Item BILL NO. 02 Qty Unit Rate Rupiahs
PARKING AND EXTERNAL 02.2 EARTHWORK
No.
WORKS

To Collection Rp. -

02.2.2 BASE COURSES, CONT'D

Macadam stone 5-250mm (gravel) as specified

A To Retention pit m2

B To ME Cable Duct and Sleeve m2

02.2.3 TERMITE CONTROL

Termite control to soil; The protection against termites by spraying an


insecticide on the soil or on the fill before placing the vapor and after
building completed and importing landfill; undertaken by an approved
specialist; (5 years quarantee to be given) as specified.

C To Absorption pit m2

D To Drainage m2

E To Control Box m2

02.2.4 OTHERS

Plastic sheet as specified

F To Concrete road m2

HDPE line 0.3mm as specified

G To Retention pit m2

To Collection Rp. -

COLLECTIONS

Page 02.2 /1 -

Page 02.2 /2 -

TA2459 Lesaffre Garuda 4/27 b3ba-e2a2-55be-93fa-.2


Item BILL NO. 02 Qty Unit Rate Rupiahs
PARKING AND EXTERNAL 02.2 EARTHWORK
No.
WORKS

02.2 EARTHWORK
CARRIED TO SUMMARY AT END OF BILL NO. 02 Rp. -

TA2459 Lesaffre Garuda 5/27 b3ba-e2a2-55be-93fa-.2


Item BILL NO. 02
PARKING AND EXTERNAL 02.3 CONCRETE Qty. Unit Rate Rupiahs
No.
WORKS
02.3.1 FORMWORK

02.3.1.1 IN GROUND FORMWORK

The design, certification, construction and performance of the formwork,


falsework and backpropping shall be the responsibilty of Contractor.
Proposed method of installation and removal of formwork is to be
submitted to the Superintendent for comment prior to work being carried
out as per dwg note.
In ground formwork as follows; permanent formwork system for in-place
concrete, concrete hollow block 100mm thick, finish starting at/from any
level and including rebates or grooves formers as described to

A To Road m2 -

B To Control Box m2 -

C To Absorption pit m2 -

02.3.1.2 UPPER STRUCTURE FORMWORK

Smooth-Formed Finished concrete, plywood, metal, or other approved panel


materials, finish starting at/from any level and rebates or groove formers as
specified
D To Foundation m2 -

02.3.2 CONCRETE

In-Situ Concrete

In-situ concrete designed mix Grade 25 Mpa, (K-300) NFA; ± 20mm


aggregate, vibrated with standard flatness as described ;

E To Road m3 -

F To Control Box m3 -

G To Absorption pit m3 -

H To ME Foundation and pipe sleeve m3 -

Plain in-situ concrete, designed mix grade f'c= Mpa,(K-125), 40mm


aggregate, 50mm thick as described,

I To Road m2 -

J To Control Box m2 -

K To Absorption pit m2 -

L To Foundation m2 -

TA2459 Lesaffre Garuda 6/27 b3ba-e2a2-55be-93fa-.3


Item BILL NO. 02
PARKING AND EXTERNAL 02.3 CONCRETE Qty. Unit Rate Rupiahs
No.
WORKS

To Collection Rp. -

02.3.3 REINFORCEMENT

Manufacture reinforcement bars is according to "Manual of Standard


Practice" CRSI's as follows; supply, cleaned, measurement, positioning,
setting and install. Reinforcement measure include joint dowel bars,
bolsters, chairs, spacers and other device for spacing, supporting and
fastening reinforcing bars and welded wire reinforcement in place.

A To Concrete sleeve, Wiremesh M8-150 (1 Layer) m2 -

Reinforcing bars is Grade 60/420 deformed or Grade BJTD 40 deformed.


round mild steel, as described in

B To Road kg -

C To Control Box kg -

D To Absorption pit kg -

E To Absorption pit kg -

F To Absorption pit kg -

G To Foundation kg -

02.3.4 DRAINAGE

Supply and install drain concrete precast U Channel complete with light
duty concrete cover as specified

H UC200 - m

I UC300 - m

J UC300x200 - m

K UC400 - m

L UC500 - m

M UC600 - m

N UC800 - m

Supply and install drain concrete precast U Channel complete with heavy
duty concrete cover as specified

O UG300 - m

P UG400 - m

Q UG500 - m

R UG600 - m

TA2459 Lesaffre Garuda 7/27 b3ba-e2a2-55be-93fa-.3


Item BILL NO. 02
PARKING AND EXTERNAL 02.3 CONCRETE Qty. Unit Rate Rupiahs
No.
WORKS

To Collection Rp. -

02.3.4 DRAINAGE, CONT'D

Supply and install drain concrete precast as specified

A OD200 m

B OD300 m

C OD300x200 m

D OD400 m

E OD500 m

F OD800 m

Supply and install concrete RCP and Culvert as specified

G RCP 800 m

H Box Culvert 1000 m

02.3.5 SUNDRIES

I Supply and Install Conblock paving K400 80mm thick as specified m2

J Supply and Install Conblock paving K400 100mm thick as specified m2

K Supply and Install Concrete curb including drain hole, accessories, and m
support as drawing and specification

L Supply and Install Stone masonry as specified m3

M Supply and Install Man ladder D16-200 c/c complete with baseplate, nos
anchor, and all accessories and support as drawing and specification

N Supply and Install Isolation joint system as drawing and specification m

O Supply and Install FDC joint system as drawing and specification m

P Supply and Install IDC joint system as drawing and specification m

TA2459 Lesaffre Garuda 8/27 b3ba-e2a2-55be-93fa-.3


Item BILL NO. 02
PARKING AND EXTERNAL 02.3 CONCRETE Qty. Unit Rate Rupiahs
No.
WORKS

To Collection Rp. -

COLLECTIONS

Page 02.3 /1 -

Page 02.3 /2 -

Page 02.3 /3 -

TA2459 Lesaffre Garuda 9/27 b3ba-e2a2-55be-93fa-.3


Item BILL NO. 02
PARKING AND EXTERNAL 02.3 CONCRETE Qty. Unit Rate Rupiahs
No.
WORKS

02.3 CONCRETE
CARRIED TO SUMMARY AT END OF BILL NO. 02 Rp. -

TA2459 Lesaffre Garuda 10/27 b3ba-e2a2-55be-93fa-.3


Item BILL NO. 02
PARKING AND EXTERNAL 02.4 MASONRY Qty. Unit Rate Rupiahs
No
WORKS
02.4.1 UNIT MASONRY

Supply and Install Autoclaved aerated concrete block wall with mortar;
including reinforced concrete bonding ties, anchorage, latching, stiffener
columns and lintels beams as required, all in accordancce with drawings
and specifications
A To Wall 150mm thick m2

Concrete Roaster as specified

B To Wall m2

02.4.2 PLASTERED

Plaster; Mortar instant trowelled smooth with and including cement coating
instant as described

C To Wall 150mm thick m2

02.4 MASONRY
CARRIED TO SUMMARY AT END OF BILL NO. 02 Rp. -

TA2459 Lesaffre Garuda 11/27 b3ba-e2a2-55be-93fa-.4


Item BILL NO. 02
PARKING AND EXTERNAL 02.5 METALS Qty. Unit Rate Rupiahs
No
WORKS
02.5.1 METAL WORKS

A Supply and intsall Steel grating cover complete with steel frame, steel m2
support and accessories as drawing and specification

02.5.2 GATES

Supply and install gate complete with accessories and support as drawing
and specification

B Gates nos

02.5 METALS

TA2459 Lesaffre Garuda 12/27 b3ba-e2a2-55be-93fa-.5


Item BILL NO. 02
PARKING AND EXTERNAL 02.5 METALS Qty. Unit Rate Rupiahs
No
WORKS
CARRIED TO SUMMARY AT END OF BILL NO. 02 Rp. -

TA2459 Lesaffre Garuda 13/27 b3ba-e2a2-55be-93fa-.5


Item BILL NO. 02
PARKING AND EXTERNAL 02.9. FINISHES Qty. Unit Rate Rupiahs
No
WORKS

02.9.1 FLOOR FINISHES

Prepare and apply floor marking paint as specified

A To Parking area m2

02.9.2 WALL FINISHES

Prepare smooth and apply acrylic emulsion wethershield paint finish, in


accordance with manufacturer's recommendations, as specified to face of :

B Applied to plastered autoclaved concrete walls m2

02.9. FINISHES
CARRIED TO SUMMARY AT END OF BILL NO. 02 Rp. -

TA2459 Lesaffre Garuda 14/27 b3ba-e2a2-55be-93fa-.9


Item BILL NO. 02
PARKING AND EXTERNAL 02.9. FINISHES Qty. Unit Rate Rupiahs
No
WORKS

TA2459 Lesaffre Garuda 15/27 b3ba-e2a2-55be-93fa-.9


Item BILL NO. 02
PARKING AND EXTERNAL 02.11 MECHANICAL WORKS Qty. Unit Rate Rupiahs
No
WORKS
02.11 MECHANICAL WORKS

02.11.1 DOMESTIC COLD WATER

DOMESTIC COLD WATER SYSTEM INSTALLATION


Supply and install Domestic Water pipes; Galvanized Steel Pipe BS 1387
including fittings (for 50 mm dia. Pipe or less) fixed in position complete with
seals (for underground pipe) supports, hangers, brackets, clamp, painting, and
other necessary fixing and jointing material in accordance to the technical
specification and drawings, as described;

PIPEWORKS

A 32mm diameter pipe m

B 50mm diameter pipe m

C 65mm diameter pipe m

D 80mm diameter pipe m

E 100mm diameter pipe m

FITTINGS

F Fitting 65mm diameter no

G Fitting 80mm diameter no

H Fitting 100mm diameter no

VALVE AND ANCILLARIES

I 32mm diameter gate valve no

J 40mm diameter gate valve no

K 50mm diameter gate valve no

L 65mm diameter gate valve no

M 80mm diameter gate valve no

N Pressure gauge 16 K with 4" dial stainless steel with water syphon and no
manometer holder,valve;threaded end connection

O AAV with 10 kg/cm2, dia.25 mm no

To Collection Rp. -

TA2459 Lesaffre Garuda 16/27 b3ba-e2a2-55be-93fa-.11


Item BILL NO. 02
PARKING AND EXTERNAL 02.11 MECHANICAL WORKS Qty. Unit Rate Rupiahs
No
WORKS

TA2459 Lesaffre Garuda 17/27 b3ba-e2a2-55be-93fa-.11


Item BILL NO. 02
PARKING AND EXTERNAL 02.11 MECHANICAL WORKS Qty. Unit Rate Rupiahs
No
WORKS

02.11.2 SEWAGE AND WASTE WATER SYSTEM

SEWAGE AND WASTE WATER SYSTEM INSTALLATION


Supply and Install Waste water and Sewage Water pipes; HDPE SDR11, PN10
including tape for underground pipe and PVC Class AW 10 kg/m2 for Vent
including fittings (for 50 mm dia. Pipe or less) fixed in position complete with
supports, hangers, brackets, clamp, painting, and other necessary fixing and
jointing material in accordance to the technical specification and drawings, as
described;

PIPEWORKS

A 110mm diameter pipe m

B 160mm diameter pipe m

C 200mm diameter pipe m

FITTINGS

D Fitting 110mm diameter no

E Fitting 160mm diameter no

F Fitting 200mm diameter no

VALVE AND ANCILLARIES

G 100mm diameter gate valve no

H 100mm diameter check valve


no
02.11.3 INDUSTRIAL WASTE WATER SYSTEM

INDUSTRIAL WASTE WATER SYSTEM INSTALLATION


Supply and Install Industrial Waste Water pipes; FRP pipe and FRP coated IC pipe
including excavation for undergground pipe and fittings (for 50mm dia. Pipe or
less) fixed in position complete with supports, hangers, brackets, clamp,painting,
and other necessary fixing a

PIPEWORKS

I 450mm diameter pipe; FRP m

J 450mm diameter pipe; FRP coated IC m

FITTINGS

K Fitting 450mm diameter; FRP no

L Fitting 450mm diameter; FRP coated IC no

TA2459 Lesaffre Garuda 18/27 b3ba-e2a2-55be-93fa-.11


Item BILL NO. 02
PARKING AND EXTERNAL 02.11 MECHANICAL WORKS Qty. Unit Rate Rupiahs
No
WORKS

To Collection Rp. -

TA2459 Lesaffre Garuda 19/27 b3ba-e2a2-55be-93fa-.11


Item BILL NO. 02
PARKING AND EXTERNAL 02.11 MECHANICAL WORKS Qty. Unit Rate Rupiahs
No
WORKS

02.11.4 HYDRANT & SPRINKLER SYSTEM

HYDRANT SYSTEM INSTALLATION


Supply and install Hydrant Pipes, Black steel pipe to ASTM A 53 schedule 40 ,
Grade B, including fitting (for 50 mm dia. Pipe or less) fixed in position complete
with supports, hangers, brackets, clamp, painting, and other necessary fixing and
jointing material in accordance to the technical specification and drawings, as
described;

PIPEWORKS

A 100mm diameter pipe m

B 200mm diameter pipe m

C 250mm diameter pipe m

FITTINGS

D Fitting 100mm diameter no

E Fitting 200mm diameter no

F Fitting 250mm diameter no

VALVE AND ANCILLARIES

G Main Control Valve (MCV); 250mm diameter no

H AAV; 50mm diameter no

I Test Drain; 50 mm diameter no

J 100mm diameter gate valve, UL listed & FM approved no

K 200mm diameter gate valve, UL listed & FM approved no

L 250mm diameter gate valve, UL listed & FM approved no

M Outdoor hydrant box with size 1350 x 660 x 200mm complete with hose rack, no
nozzle and rubber hose reel

N Pillar hydrant c/w gate valve no

O Siamese Connection c/w check valve no

TA2459 Lesaffre Garuda 20/27 b3ba-e2a2-55be-93fa-.11


Item BILL NO. 02
PARKING AND EXTERNAL 02.11 MECHANICAL WORKS Qty. Unit Rate Rupiahs
No
WORKS
To Collection Rp. -

TA2459 Lesaffre Garuda 21/27 b3ba-e2a2-55be-93fa-.11


Item BILL NO. 02
PARKING AND EXTERNAL 02.11 MECHANICAL WORKS Qty. Unit Rate Rupiahs
No
WORKS

COLLECTION

Page 02.11 /1 -

Page 02.11 /2 -

Page 02.11 /3 -

02.11 MECHANICAL WORKS


CARRIED TO SUMMARY AT END OF BILL NO. 02 Rp. -

TA2459 Lesaffre Garuda 22/27 b3ba-e2a2-55be-93fa-.11


Item BILL NO. 02
PARKING AND EXTERNAL 02.12 ELECTRICAL WORKS Qty. Unit Rate Rupiahs
No
WORKS
2.12 ELECTRICAL WORKS

02.12.1 LIGHTING FIXTURES & POWER OUTLET


Supply and Install the following light fittings including tubes or lamps fixed in
position complete with all accessories and support in accordance with the
technical specification and drawings, as described :-

A Single street lighting LED 140W, 220V, min 14000lm, IP66, c/w 9000mm Pole no
single arm and fondation

B Single street lighting LED 140W, 220V, min 14000lm, IP66, c/w 2500mm Pole no
mounted pipe bridge

C Flood light LED 310W, 220V, min 40000lm, IP66 c/w 7000mm pole and no
foundation (without arm)

Supply and Install lighting cables from sub circuit to final circuit including
grounding system and all neccessary accessories accordance with the technical
specification and drawings, as described :-

D Cabling point from local panel (NYFGbY 3x2.5mm² underground direct burried no
at 300mm below grade (minimum) to lighting

02.12.2 GROUNDING & LIGHTNING PROTECTION SYSTEM

Supply and Install Lightning protection system for panel and equipment
complete with support and all neccessary accessories in accordance with the
technical specification and drawings, as described :-

E Air terminal (ESE Type) c/w pole H=2 mtr, radius protection = 80mtr, installed no
on the top building

F Air terminal (ESE Type) c/w pole H=18 mtr, radius protection = 90mtr, installed no
on the level ground floor

02.12.3 PUBLIC ADDRESS


Supply and Install the following Sound System Equipment complete with support,
and all necessary accessories in accordance to the technical specification and
drawings, as described : -

G Junction box public address JBPA (include in every building system) no include

H Horn speaker 15W mounted pole lighting no

I Horn speaker 15W no

Supply and Install the following Security cables in final sub-circuit to


termination, run-in and with PVC conduit 20mm dia underground direct burried
min 400mm below grade or through pipe rack; including earthing system and all
necessary accessories in accordance to the technical spesification as shown on
drawing, as described : -

J Cable NYFGbY 2Cx1,5 mm2; for horns speaker point no

To Collection Rp. -

TA2459 Lesaffre Garuda 23/27 b3ba-e2a2-55be-93fa-.12


Item BILL NO. 02
PARKING AND EXTERNAL 02.12 ELECTRICAL WORKS Qty. Unit Rate Rupiahs
No
WORKS

TA2459 Lesaffre Garuda 24/27 b3ba-e2a2-55be-93fa-.12


Item BILL NO. 02
PARKING AND EXTERNAL 02.12 ELECTRICAL WORKS Qty. Unit Rate Rupiahs
No
WORKS

02.12.3 SECURITY SYSTEM


Supply and Install the following Security System Equipment complete with
support, and all necessary accessories in accordance to the technical specification
and drawings, as described : -

A Wall mounted switch rack (include in every building system) no include

B IP based bullet camera outdoor type IP65/IK10, min 4 MP, VF, POE, mounted no
on pole

Supply and Install the following Security cables in final sub-circuit to


termination, run-in and with PVC conduit 25mm dia underground direct burried
min 400mm below grade or through pipe rack; including earthing system and all
necessary accessories in accordance to the technical spesification as shown on
drawing, as described : -

C FO cable 4Cores-MM-OM3/armoured + NYFGbY 2x1.5mm2 for camera point no

To Collection Rp. -

COLLECTION

Page 02.12 /1 -

Page 02.12 /2 -

02.12 ELECTRICAL WORKS


CARRIED TO SUMMARY AT END OF BILL NO. 02 Rp. -

TA2459 Lesaffre Garuda 25/27 b3ba-e2a2-55be-93fa-.12


Item BILL NO. 02
PARKING AND EXTERNAL 02.12 ELECTRICAL WORKS Qty. Unit Rate Rupiahs
No
WORKS

TA2459 Lesaffre Garuda 26/27 b3ba-e2a2-55be-93fa-.12


Item BILL NO. 02
PARKING AND EXTERNAL 02.3 HVAC WORKS Qty. Unit Rate Rupiahs
No
WORKS

02.3 HVAC WORKS


CARRIED TO SUMMARY AT END OF BILL NO. 02 Rp. N/A

TA2459 Lesaffre Garuda 27/27 b3ba-e2a2-55be-93fa-.13


BILL NO. 14
COOLING TOWER

TA2459 Lesaffre Garuda 1/12 b183-0319-00e6-44a6-Cover


Item BILL NO. 14 SUMMARY RUPIAHS
No. COOLING TOWER

SUMMARY

14.1 DEMOLITION N/A

14.2 EARTHWORK -

14.3 CONCRETE -

14.4 MASONRY N/A

14.5 METALS N/A

14.7 THERMAL AND MOISTURE PROTECTION N/A

14.8 DOORS AND WINDOWS N/A

14.9. FINISHES N/A

14.10 SPECIALITIES N/A

14.11 MECHANICAL WORKS N/A

14.2 ELECTRICAL WORKS N/A

14.3 HVAC WORKS N/A

BILL NO. 14
CARRIED TO SUMMARY -

TA2459 Lesaffre Garuda 2/12 b183-0319-00e6-44a6-Sum


Item BILL NO. 14 Qty Unit Rate Rupiahs
14.2 EARTHWORK
No. COOLING TOWER

14.2.1 CUT OFF PILE HEAD

Cut off pile head as drawings

A Spun pile, dia. 400mm nos

14.2.2 EARTHWORK

Excavation, disposal and backfill in any material including rock or hard


material, working space at parimeter items as defined; Excavating, starting
from stripped level, trenches to receive depth as pecified (insite area)

B To Pile Cap m3

C To Slab m3

D To Tie Beam m3

14.2.3 BASE COURSES

Compacted of subgrade to 95% Standard Proctor Density as specified

E To Pile Cap m2

F To Slab m2

G To Tie Beam m2

Sandfill 100mm thick as specified

H To Pile Cap m2

I To Slab m2

J To Tie Beam m2

14.2.4 TERMITE CONTROL

Termite control to soil; The protection against termites by spraying an


insecticide on the soil or on the fill before placing the vapor and after
building completed and importing landfill; undertaken by an approved
specialist; (5 years quarantee to be given) as specified.

K To Pile Cap m2

L To Slab m2

M To Tie Beam m2

14.2.5 OTHERS

Plastic sheet

N To Pile Cap m2

O To Slab m2

P To Tie Beam m2

TA2459 Lesaffre Garuda 3/12 b183-0319-00e6-44a6-2.2


Item BILL NO. 14 Qty Unit Rate Rupiahs
14.2 EARTHWORK
No. COOLING TOWER

14.2 EARTHWORK
CARRIED TO SUMMARY AT END OF BILL NO. 14 Rp. -

TA2459 Lesaffre Garuda 4/12 b183-0319-00e6-44a6-2.2


Item BILL NO. 14
14.3 CONCRETE Qty. Unit Rate Rupiahs
No. COOLING TOWER

14.3.1 FORMWORK

14.3.1.1 IN GROUND FORMWORK

The design, certification, construction and performance of the formwork,


falsework and backpropping shall be the responsibilty of Contractor.
Proposed method of installation and removal of formwork is to be
submitted to the Superintendent for comment prior to work being carried
out as per dwg note.
In ground formwork as follows; permanent formwork system for in-place
concrete, concrete hollow block 100mm thick, finish starting at/from any
level and including rebates or grooves formers as described to

A To Pile Cap m2 -

B To Slab m2 -

C To Tie Beam m2 -

14.3.1.2 UPPER STRUCTURE FORMWORK

Smooth-Formed Finished concrete, plywood, metal, or other approved


panel materials, finish starting at/from any level and rebates or groove
formers as specified

D To Pedestal and Column m2 -

E To Wall m2 -

14.3.2 CONCRETE

In-Situ Concrete

In-situ concrete designed mix Grade 30 Mpa, (K-350) NFA; ± 20mm


aggregate, vibrated with standard flatness as described ;

F To Pile Cap m3 -

G To Slab m3 -

H To Tie Beam m3 -

I To Pedestal and Column m3 -

J To Wall m3 -

Lean Concrete

Plain in-situ concrete, designed mix grade f'c= Mpa,(K-125), 40mm


aggregate, 50mm thick as described,

K To Pile Cap m2 -

L To Slab m2 -

M To Tie Beam m2 -

TA2459 Lesaffre Garuda 5/12 b183-0319-00e6-44a6-2.3


Item BILL NO. 14
14.3 CONCRETE Qty. Unit Rate Rupiahs
No. COOLING TOWER

To Collection Rp. -

14.3.3 REINFORCEMENT

Manufacture reinforcement bars is according to "Manual of Standard


Practice" CRSI's as follows; supply, cleaned, measurement, positioning,
setting and install. Reinforcement measure include joint dowel bars,
bolsters, chairs, spacers and other device for spacing, supporting and
fastening reinforcing bars and welded wire reinforcement in place.

Reinforcing bars is Grade 60/420 deformed or Grade BJTD 40 deformed.


round mild steel, as described in

A Dia. 16mm, To Pile Cap kg -

B Dia. 19mm, To Slab kg -

C Dia. 16mm, To Tie Beam kg -

D Dia. 10mm, To Tie Beam kg -

E Dia. 16mm, To Pedestal and Column kg -

F Dia. 10mm, To Pedestal and Column kg -

G Dia. 16mm, To Wall kg -

H Dia. 10mm, To Wall kg -

14.3.4 SUNDRIES

I Waterstop joint, sika water including all necessary per drawings and m
specification

To Collection Rp. -

COLLECTION

Page 14.3 /1 -

Page 14.3 /2 -

TA2459 Lesaffre Garuda 6/12 b183-0319-00e6-44a6-2.3


Item BILL NO. 14
14.3 CONCRETE Qty. Unit Rate Rupiahs
No. COOLING TOWER

14.3 CONCRETE
CARRIED TO SUMMARY AT END OF BILL NO. 14 Rp. -

TA2459 Lesaffre Garuda 7/12 b183-0319-00e6-44a6-2.3


Item BILL NO. 14
14.11 MECHANICAL WORKS Qty. Unit Rate Rupiahs
No COOLING TOWER

14.11 MECHANICAL WORKS


CARRIED TO SUMMARY AT END OF BILL NO. 14 Rp. N/A

TA2459 Lesaffre Garuda 8/12 b183-0319-00e6-44a6-2.11


Item BILL NO. 14
14.11 MECHANICAL WORKS Qty. Unit Rate Rupiahs
No COOLING TOWER

TA2459 Lesaffre Garuda 9/12 b183-0319-00e6-44a6-2.11


Item BILL NO. 14
14.2 ELECTRICAL WORKS Qty. Unit Rate Rupiahs
No COOLING TOWER

14.2 ELECTRICAL WORKS


CARRIED TO SUMMARY AT END OF BILL NO. 14 Rp. N/A

TA2459 Lesaffre Garuda 10/12 b183-0319-00e6-44a6-2.12


Item BILL NO. 14
14.2 ELECTRICAL WORKS Qty. Unit Rate Rupiahs
No COOLING TOWER

TA2459 Lesaffre Garuda 11/12 b183-0319-00e6-44a6-2.12


Item BILL NO. 14
14.3 HVAC WORKS Qty. Unit Rate Rupiahs
No COOLING TOWER

14.3 HVAC WORKS


CARRIED TO SUMMARY AT END OF BILL NO. 14 Rp. N/A

TA2459 Lesaffre Garuda 12/12 b183-0319-00e6-44a6-2.13


BILL NO. 21
ELECTRICAL SUBSTATION

TA2459 Lesaffre Garuda 1/24 2a0c-d555-db7d-d6c0-Cover


Item BILL NO. 21 SUMMARY RUPIAHS
No. ELECTRICAL SUBSTATION

SUMMARY

21.1 PILING WORKS -

21.2 EARTHWORK -

21.3 CONCRETE -

21.4 MASONRY -

21.5 METALS -

21.7 THERMAL AND MOISTURE PROTECTION -

21.8 DOORS AND WINDOWS -

21.9. FINISHES -

21.10 SPECIALITIES N/A

21.11 MECHANICAL WORKS -

21.12 ELECTRICAL WORKS -

21.13 HVAC WORKS -

BILL NO. 21
CARRIED TO SUMMARY -

TA2459 Lesaffre Garuda 2/24 2a0c-d555-db7d-d6c0-Sum


Item BILL NO. 21
21.1 PILING WORKS Qty. Unit Rate Rupiahs
No. ELECTRICAL SUBSTATION

21.1 PILINGS

21.1.1 DRILLING WORKS

Drilling works (Preboring) as specified in drawings

A Dia.350mm, L=12mm m

Soil disposal as specified

B Dia.350mm, L=12mm (disposed m3


insite)

21.1.2 SUPPLY OF PILES

Supply pre-cast prestressed reinforced concrete piles grade K-600 kg/cm2


including reinforcement pile, pencil shoe and end plate

C Spun pile; dia. 400mm, L=9m nr

21.1.3 PILES DRIVING

Pitching and driving pre-cast prestressed reinforced concrete piles with


hydrolic or diesel hammer system as described

D Spun pile; dia. 400mm, L=9m m

Jointing of piles incl. welding

E Spun pile; dia. 400mm (Plate/joint included in piles, welding only) nos

Others

F Dolly no Rate only

G Re-drive no Rate only

21.1.2 PILES TESTING

H Pile dynamic testing with PDA, including CAPWAP analysis and report by nos
independent contractor

I Pile integrity testing with PIT system including analysis and report for new nos

TA2459 Lesaffre Garuda 3/24 2a0c-d555-db7d-d6c0-2.1


Item BILL NO. 21
21.1 PILING WORKS Qty. Unit Rate Rupiahs
No. ELECTRICAL SUBSTATION
21.1 PILING WORKS
CARRIED TO SUMMARY AT END OF BILL NO. 21 Rp. -

TA2459 Lesaffre Garuda 4/24 2a0c-d555-db7d-d6c0-2.1


Item BILL NO. 21 Qty Unit Rate Rupiahs
21.2 EARTHWORK
No. ELECTRICAL SUBSTATION

21.2.1 CUT OFF PILE HEAD

Cut off pile head as drawings

A Spun pile, dia. 400mm nos

21.2.2 EARTHWORK

Excavation, disposal and backfill in any material including rock or hard


material, working space at parimeter items as defined; Excavating, starting
from stripped level, trenches to receive depth as pecified (insite area)

B To Pile Cap m3

C To Slab incl. ramp m3

D To Tie Beam m3

E To Pedestal m3

21.2.3 BASE COURSES

Compacted of subgrade to 95% Standard Proctor Density as specified

F To Pile Cap m2

G To Slab incl. ramp m2

H To Tie Beam m2

Sandfill 100mm thick as specified

I To Pile Cap m2

J To Slab incl. ramp m2

K To Tie Beam m2

L To Levelling Under ramp m2

Compacted gravel as specified

M To Ramp m2

21.2.4 TERMITE CONTROL

Termite control to soil; The protection against termites by spraying an


insecticide on the soil or on the fill before placing the vapor and after
building completed and importing landfill; undertaken by an approved
specialist; (5 years quarantee to be given) as specified.

N To Pile Cap m2

O To Slab incl. ramp m2

P To Tie Beam m2

Q To Pedestal m2

TA2459 Lesaffre Garuda 5/24 2a0c-d555-db7d-d6c0-2.2


Item BILL NO. 21 Qty Unit Rate Rupiahs
21.2 EARTHWORK
No. ELECTRICAL SUBSTATION

To Collection Rp. -

21.2.5 OTHERS

Plastic sheet

A To Pile Cap m2

B To Slab incl. ramp m2

C To Tie Beam m2

To Collection Rp. -

COLLECTIONS

Page 21.2/1 -

Page 21.2/2 -

21.2 EARTHWORK

TA2459 Lesaffre Garuda 6/24 2a0c-d555-db7d-d6c0-2.2


Item BILL NO. 21 Qty Unit Rate Rupiahs
21.2 EARTHWORK
No. ELECTRICAL SUBSTATION

CARRIED TO SUMMARY AT END OF BILL NO. 21 Rp. -

TA2459 Lesaffre Garuda 7/24 2a0c-d555-db7d-d6c0-2.2


Item BILL NO. 21
21.3 CONCRETE Qty. Unit Rate Rupiahs
No. ELECTRICAL SUBSTATION

21.3.1 FORMWORK

21.3.1.1 IN GROUND FORMWORK

The design, certification, construction and performance of the formwork,


falsework and backpropping shall be the responsibilty of Contractor.
Proposed method of installation and removal of formwork is to be
submitted to the Superintendent for comment prior to work being carried
out as per dwg note.
In ground formwork as follows; permanent formwork system for in-place
concrete, concrete hollow block 100mm thick, finish starting at/from any
level and including rebates or grooves formers as described to

A To Pile Cap m2 -

B To Slab Incl. Ramp m2 -

C To Tie Beam m2 -

21.3.1.2 UPPER STRUCTURE FORMWORK

Smooth-Formed Finished concrete, plywood, metal, or other approved


panel materials, finish starting at/from any level and rebates or groove
formers as specified

D To Slab m2 -

E To Beam m2 -

F To Pedestal and Column m2 -

G To Wall/Parapet Incl. Under Ramp m2 -

21.3.2 CONCRETE

In-Situ Concrete

In-situ concrete designed mix Grade 30 Mpa, (K-350) NFA; ± 20mm


aggregate, vibrated with standard flatness as described ;

H To Pile Cap m3 -

I To Slab and Roof Incl. Ramp m3 -

J To Tie Beam and Upper Beam m3 -

K To Pedestal and Column m3 -

L To Wall/Parapet Incl. Under Ramp m3 -

Lean Concrete

Plain in-situ concrete, designed mix grade f'c= Mpa,(K-125), 40mm


aggregate, 50mm thick as described,

M To Pile Cap m2 -

TA2459 Lesaffre Garuda 8/24 2a0c-d555-db7d-d6c0-2.3


Item BILL NO. 21
21.3 CONCRETE Qty. Unit Rate Rupiahs
No. ELECTRICAL SUBSTATION

To Collection Rp. -

21.3.2 CONCRETE, CONT'D

Lean Concrete

Plain in-situ concrete, designed mix grade f'c= Mpa,(K-125), 40mm


aggregate, 50mm thick as described,

A To Slab Incl. Ramp m2 -

B To Tie Beam m2 -

21.3.3 REINFORCEMENT

Manufacture reinforcement bars is according to "Manual of Standard


Practice" CRSI's as follows; supply, cleaned, measurement, positioning,
setting and install. Reinforcement measure include joint dowel bars,
bolsters, chairs, spacers and other device for spacing, supporting and
fastening reinforcing bars and welded wire reinforcement in place.

Reinforcing bars is Grade 60/420 deformed or Grade BJTD 40 deformed.


round mild steel, as described in

C Dia. 16mm, To Pile Cap kg -

D Dia. 13mm, To Pile Cap kg -

E Dia. 13mm, To Slab and Roof Incl. Ramp kg -

F Dia. 10mm To Slab and Roof Incl. Ramp kg -

G Dia. 22mm, To Tie Beam and Upper Beam kg -

H Dia. 19mm, To Tie Beam and Upper Beam kg -

I Dia. 16mm, To Tie Beam and Upper Beam kg -

J Dia. 10mm, To Tie Beam and Upper Beam kg -

K Dia. 19mm, To Pedestal and Column kg -

L Dia. 10mm, To Pedestal and Column kg -

M Dia. 13mm, To Wall/Parapet kg -

N Dia. 10mm, To Wall/Parapet kg -

21.3.4 SUNDRIES

O Flexible joint filler, folytirene 5mm thick per drawings and specification m

TA2459 Lesaffre Garuda 9/24 2a0c-d555-db7d-d6c0-2.3


Item BILL NO. 21
21.3 CONCRETE Qty. Unit Rate Rupiahs
No. ELECTRICAL SUBSTATION

To Collection Rp. -

COLLECTIONS

Page 21.3 /1 -

Page 21.3 /2 -

TA2459 Lesaffre Garuda 10/24 2a0c-d555-db7d-d6c0-2.3


Item BILL NO. 21
21.3 CONCRETE Qty. Unit Rate Rupiahs
No. ELECTRICAL SUBSTATION

21.3 CONCRETE
CARRIED TO SUMMARY AT END OF BILL NO. 21 Rp. -

TA2459 Lesaffre Garuda 11/24 2a0c-d555-db7d-d6c0-2.3


Item BILL NO. 21
21.4 MASONRY Qty. Unit Rate Rupiahs
No ELECTRICAL SUBSTATION

21.4.1 UNIT MASONRY

Supply and Install Autoclaved aerated concrete block wall with mortar;
including reinforced concrete bonding ties, anchorage, latching, stiffener
columns and lintels beams as required, all in accordancce with drawings
and specifications
A To Wall 150mm thick External Wall m2 -

B To Wall 150mm thick Internal Wall m2 -

21.4.2 PLASTERED

Plaster; Mortar instant trowelled smooth with and including cement coating
instant as described

C To Wall 150mm thick m2 -

21.4 MASONRY
CARRIED TO SUMMARY AT END OF BILL NO. 21 Rp. -

TA2459 Lesaffre Garuda 12/24 2a0c-d555-db7d-d6c0-2.4


Item BILL NO. 21 21.5 METALS
Qty. Unit Rate Rupiahs
No ELECTRICAL SUBSTATION

21.5.1 STEEL STAIR

A Supply and install cage ladder including landing step, connecting plates no -
and all fixing accessories and support as drawing and specification - to

21.5.2 RAILING

Supply and Install steel pipe railing including handrail support and knee
railing complete with kick plate, anchor bolt and all necessary fixing
accessories as drawings and specifications

B To external ramp m -

21.5 METALS
CARRIED TO SUMMARY AT END OF BILL NO. 21 Rp. -

TA2459 Lesaffre Garuda 13/24 2a0c-d555-db7d-d6c0-2.5


Item BILL NO. 21 21.5 METALS
Qty. Unit Rate Rupiahs
No ELECTRICAL SUBSTATION

TA2459 Lesaffre Garuda 14/24 2a0c-d555-db7d-d6c0-2.5


Item BILL NO. 21 21.7 THERMAL AND MOISTURE Qty Unit Rate Rupiahs
No. ELECTRICAL SUBSTATION PROTECTION

21.7.1 ROOF SPECIALITIES

Supply and Install down pipe complete with overflow, steel clamp, support,
fitting, bracket, steel unp, and all fixing accessories; all in accordance with
drawings and specifications

A PVC Downpipe Ø4" m -

B Cast iron strainer nos -

Supply and install concrete waterproofing liquid membrane complete with


accessories and support; all in accordance with manufacturer's instruction,
drawings, and specifications

C To Roof m2 -

21.7.2 SUNDRIES

D Balustrade strip as drawing and specification m -

21.7 THERMAL AND MOISTURE PROTECTION


CARRIED TO SUMMARY AT END OF BILL NO. 21 Rp. -

TA2459 Lesaffre Garuda 15/24 2a0c-d555-db7d-d6c0-2.7


Item BILL NO. 21
21.8 DOORS AND WINDOWS Qty. Unit Rate Rupiahs
No. ELECTRICAL SUBSTATION

21.8.1 DOORS

Supply and install steel door including vision panel / louvre, frames,
hardwares, treshold, steel plate, and all fixing accessories and supports as
drawings and specifications

A 21.DF.003 no -

B 21.DF.002 no -

C 21.DF.004 no -

D 21.DF.005 no -

21.8.3 LOUVRES AND GLASSBLOCK

Supply and install steel louvre complete with removable insect screen,
hardwares, and all necessary components, fixing, accessories as drawing
and specification.

E 21.LA.001 no -

F 21.LA.002 no -

G Glassblock nos -

21.8 DOORS AND WINDOWS


CARRIED TO SUMMARY AT END OF BILL NO. 21 Rp. -

TA2459 Lesaffre Garuda 16/24 2a0c-d555-db7d-d6c0-2.8


Item BILL NO. 21
21.9. FINISHES Qty. Unit Rate Rupiahs
No ELECTRICAL SUBSTATION

21.9.1 FLOOR FINISHES

Prepare and apply floor hardener; all in accordance with manufacturer's


instruction, drawings, and specifications

A To Floor m2 -

Prepare and apply PU paint; all in accordance with manufacturer's


instruction, drawings, and specifications

B To Coving m -

Supply and install raised floor; all in accordance with manufacturer's


instruction, drawings, and specifications

C To Floor m2 -

21.9.2 WALL FINISHES

Prepare smooth and apply waterbased acrylic emulsion paint finish, in


accordance with manufacturer's recommendations, as specified to face of :

D Applied to plastered autoclaved concrete walls (Internal Wall) m2 -

Prepare smooth and apply waterbased wethershield emulsion paint finish,


in accordance with manufacturer's recommendations, as specified to face of

E Applied to plastered autoclaved concrete walls (External Wall) m2 -

F Applied to parapet wall

Prepare smooth and apply skimcoat, in accordance with manufacturer's


recommendations, as drawing and specification

H To Exposed Concrete Wall m2 -

21.9.3 CEILING FINISHES

Prepare smooth and apply waterbased acrylic emulsion paint finish, in


accordance with manufacturer's recommendations, as specified to face of :

F To Ceiling m2 -

Prepare smooth and apply skimcoat, in accordance with manufacturer's


recommendations, as drawing and specification

G To Exposed Concrete Ceiling m2 -

21.9. FINISHES
CARRIED TO SUMMARY AT END OF BILL NO. 21 Rp. -

TA2459 Lesaffre Garuda 17/24 2a0c-d555-db7d-d6c0-2.9


Item BILL NO. 21
21.10 SPECIALITIES Qty. Unit Rate Rupiahs
No ELECTRICAL SUBSTATION

21.10 SPECIALITIES
CARRIED TO SUMMARY AT END OF BILL NO. 21 Rp. N/A

TA2459 Lesaffre Garuda 18/24 2a0c-d555-db7d-d6c0-2.10


Item BILL NO. 21
21.11 MECHANICAL WORKS Qty. Unit Rate Rupiahs
No ELECTRICAL SUBSTATION

21.11 ELECTRICAL WORKS

21.11.1 HYDRANT & SPRINKLER SYSTEM

Supply and install Hydrant Pipes, Black steel pipe to ASTM A 53 schedule 40 ,
Grade B, including fitting (for 50 mm dia. Pipe or less) fixed in position complete
with supports, hangers, brackets, clamp, painting, and other necessary fixing and
jointing material in accordance to the technical specification and drawings, as
described;

VALVE AND ANCILLARIES

A Portable fire extinguisher with capacity 6 kg chemical powder ABC type. no

21.11 MECHANICAL WORKS


CARRIED TO SUMMARY AT END OF BILL NO. 21 Rp. -

TA2459 Lesaffre Garuda 19/24 2a0c-d555-db7d-d6c0-2.11


Item BILL NO. 21
21.12 ELECTRICAL WORKS Qty. Unit Rate Rupiahs
No ELECTRICAL SUBSTATION

21.12 ELECTRICAL WORKS

21.12.1 SUB DISTRIBUTION BOARDS


Supply, Install and Testing Commissioning the following Sub Distribution board
fix in position includes circuit breaker, board, busbar, digital multimeter,
contactor, surge arrester, potensial transformer, current transformer, indicator
lamp, fuse, loto, star / stop push button, and all necessary accessories in
arcondance to the technical spesification as shown on drawing, as described : -

A 21DB01 no

B 21DBAC01 no

21.12.2 MAIN AND SUB-MAINS CABLES


Supply and Install the following Main and Sub-Mains circuit distribution cable
run & fixed on cable tray/ladders including all necessary accessories in
arcondance to the technical spesification as shown on drawing, as described : -

C From SDB…. to 21DB01 m by other package

21.12.3 LIGHTING FIXTURES & POWER OUTLET


Supply and Install the following light fittings including tubes or lamps fixed in
position complete with all accessories and support in accordance with the
technical specification and drawings, as described :-

D High bay LED 75W, 10503, 220V, surface mounted 12 no

E High bay LED 75W, 10503, 220V, surface mounted c/w nicad battery, rated 2 no
duration 1 hour

F Waterproof batten LED 20W, 220V, IP65, 2000lm, L600 c/w nicad battery, 4 no
rated duration 1 hour

G Batten LED 40W, 220V, 4100lm, mounted on the trunking 20 no

H Batten LED 40W, 220V, 4100lm, mounted on the trunking c/w nicad battery, 5 no
rated duration 1 hour

Supply and Install the following switches including provision of steel/metal box
and all accessories accordance with the technical specification and drawings, as
described :-

H Double gang, 1 way switch, 10A 4 no

Supply and Install lighting & switch cables from sub circuit to final circuit
including grounding system and all neccessary accessories accordance with the
technical specification and drawings, as described :-

I Cabling point from local panel (NYM 3C x 2.5 mm² run-in and with PVC high 47 no
impact conduit) to; lighting and switch

To Collection Rp. -

TA2459 Lesaffre Garuda 20/24 2a0c-d555-db7d-d6c0-2.12


Item BILL NO. 21
21.12 ELECTRICAL WORKS Qty. Unit Rate Rupiahs
No ELECTRICAL SUBSTATION

21.12.3 LIGHTING FIXTURES & POWER OUTLET (Cont'd)

POWER OUTLET
Supply and Install the following power outlet including provision of steel/metal
box and all accessories accordance with the Technical Specification and
drawings, as described :-

A General socket outlet c/w cover , wall mounted, 16A, 250V, (Waterproof) single 9 no
gang

B Industrial socket outlet, wall mounted, 32A, 400V, IP65 1 no

21.12.4 TRAYS AND LADDERS


Supply and Install hot dip galvanized tray and ladder 2mm thickness include
jointing, elbow, tee, fixing accessories and hangers and all necessary accessories
accordance with the technical specification and drawings, as described :-

Electrical

C Cable tray 300x100 m

Electronic

D Cable tray 200x100 m

21.12.5 GROUNDING & LIGHTNING PROTECTION SYSTEM

Supply and Install Grounding system for panel and equipment complete with
support and all neccessary accessories accordance with the technical
specification and drawings, as described :-

E Earth pit, Conductor clamp and rod electrode, dia 19mm x 3000 length no

F Earthing bonding bar (copper bar) 40x3mm thk, c/w isolator no

G BC 70mm2, grounding cable for main/mesh earthing c/w connector and m


grounding lug

H Potential earth clamp (100kA) no

I Bonding cable NYAF 35mm2 m

FIRE ALARM
Supply and Install the following Fire Alarm Equipment complete with support, and
all necessary accessories in accordance to the technical specification and
drawings, as described : -

K JBFA-21-01 1 no

L Addressable photoelectric smoke detector 10 no

M Horn & strobe light 4 no

To Collection Rp. -

TA2459 Lesaffre Garuda 21/24 2a0c-d555-db7d-d6c0-2.12


Item BILL NO. 21
21.12 ELECTRICAL WORKS Qty. Unit Rate Rupiahs
No ELECTRICAL SUBSTATION

21.12.6 FIRE ALARM (Cont'd)


Supply and Install the following Fire Alarm cables in final sub-circuit to
termination, run-in and with steel conduit 20mm dia; including earthing system
and all necessary accessories in accordance to the technical spesification as
shown on drawing, as described : -

A Cable FRC STP 2Cx1,5 mm2; for smoke detector point 10 no

B Cable FRC 2Cx1,5 mm2; for horn & strobe light point 4 no

C Cable FRC 2Cx2,5 mm2; from BD50 1 ls

PUBLIC ADDRESS
Supply and Install the following Sound System Equipment complete with support,
and all necessary accessories in accordance to the technical specification and
drawings, as described : -

D Wall mounted switch rack JBPA-21-01 (SR-21-01) 1 no

E Column speaker 10W 3 no

Supply and Install the following Public Address cables in final sub-circuit to
termination, run-in and with steel conduit 20mm dia; including earthing system
and all necessary accessories in accordance to the technical spesification as
shown on drawing, as described : -

F Cable FO OM3; from BD96 m

G Cable NYMHY 2Cx1,5 mm2; for column speaker point 3 no

DATA AND TELEPHONE


Supply and Install the following Data and Communication System
Equipment complete with support, and all necessary accessories in
accordance to the technical specification and drawings, as described : -

H Wall mounted switch rack SR-21-01 1 no

I Single gang type data outlet (RJ45) 2 no

Supply and Install the following Data and Telephone cables in final sub-circuit
to termination, run-in and with steel conduit 20mm dia; including earthing system
and all necessary accessories in accordance to the technical spesification as
shown on drawing, as described : -

J Cable UTP-CAT6/FO mm2; for data outlet point 2 no

K Cable FO OM3; from BD96 m

To Collection Rp. -

TA2459 Lesaffre Garuda 22/24 2a0c-d555-db7d-d6c0-2.12


Item BILL NO. 21
21.12 ELECTRICAL WORKS Qty. Unit Rate Rupiahs
No ELECTRICAL SUBSTATION

COLLECTIONS

Page 21.12/1 -

Page 21.12/2 -

Page 21.12/3 -

21.12 ELECTRICAL WORKS


CARRIED TO SUMMARY AT END OF BILL NO. 21 Rp. -

TA2459 Lesaffre Garuda 23/24 2a0c-d555-db7d-d6c0-2.12


Item BILL NO. 21
21.13 HVAC WORKS Qty. Unit Rate Rupiahs
No ELECTRICAL SUBSTATION

21.13 ELECTRICAL WORKS

21.13.1 EQUIPMENT

AIR CONDITIONING
Supply and Install of Air Conditioning Units complete with hangers/supports,
vibration mountings, neoprene pads and all necessary accessories in accordance
to the technical specification and drawings, as described : -

A IU/OU-Dx.21.00.01A, cooling capacity 9 kWth no

B IU/OU-Dx.21.00.01B, cooling capacity 9 kWth no

C IU/OU-Dx.21.00.02A, cooling capacity 10.5 kWth no

D IU/OU-Dx.21.00.02B, cooling capacity 10.5 kWth no

E IU/OU-Dx.21.00.02C, cooling capacity 10.5 kWth no

F IU/OU-Dx.21.00.02D, cooling capacity 10.5 kWth no

FAN
Supply and Install of Fan Units complete with hangers/supports, vibration
mountings, neoprene pads and all necessary accessories in accordance to the
technical specification and drawings, as described : -

G Exhasut Fan EF-21.00.01A, cap 4411 CMH no

H Exhasut Fan EF-21.00.01B, cap 4411 CMH no

I Exhasut Fan EF-21.00.02, cap 4389 CMH no

21.13.2 REFRIGERANT & DRAIN PIPES


Supply and install the following Refrigerant Copper Pipeworks including FM
Approved insulation ,vapour barrier, trap, fittings (for 50mm diameter pipe or
less), joints, flanges, support and all accessories in accordance to the technical
specification and drawings, as described : -

J 9,5 mm diameter pipe copper c/w insulation m

K 15,9 mm diameter pipe copper c/w insulation m

DRAIN PIPES
L 25 mm diameter pipe PVC Class AW c/w insulation m

21.13 HVAC WORKS


CARRIED TO SUMMARY AT END OF BILL NO. 21 Rp. -

TA2459 Lesaffre Garuda 24/24 2a0c-d555-db7d-d6c0-2.13


BILL NO. 31
MOLASSES STORAGE

TA2459 Lesaffre Garuda 1/21 e783-50c7-d64b-56dd-Cover


Item BILL NO. 31 SUMMARY RUPIAHS
No. MOLASSES STORAGE

SUMMARY

31.1 DEMOLITION N/A

31.2 EARTHWORK -

31.3 CONCRETE -

31.4 MASONRY -

31.5 METALS -

31.7 THERMAL AND MOISTURE PROTECTION -

31.8 DOORS AND WINDOWS -

31.9. FINISHES -

31.10 SPECIALITIES N/A

31.11 MECHANICAL WORKS N/A

31.2 ELECTRICAL WORKS -

31.3 HVAC WORKS N/A

BILL NO. 31
CARRIED TO SUMMARY -

TA2459 Lesaffre Garuda 2/21 e783-50c7-d64b-56dd-Sum


Item BILL NO. 31
31.1 DEMOLITION Qty. Unit Rate Rupiahs
No. MOLASSES STORAGE

31.1 DEMOLITION
CARRIED TO SUMMARY AT END OF BILL NO. 31 Rp. N/A

TA2459 Lesaffre Garuda 3/21 e783-50c7-d64b-56dd-2.1


Item BILL NO. 31 Qty Unit Rate Rupiahs
31.2 EARTHWORK
No. MOLASSES STORAGE

31.2.1 CUT OFF PILE HEAD

Cut off pile head as drawings

A Spun pile, dia. 800mm nos

31.2.2 EARTHWORK

Excavation, disposal and backfill in any material including rock or hard


material, working space at parimeter items as defined; Excavating, starting
from stripped level, trenches to receive depth as pecified (insite area)

B To Footings m3

C To Slab on Ground Incl. slab guard room m3

D To Tank Foundation m3

E To Wall m3

31.2.3 BASE COURSES

Compacted of subgrade to 95% Standard Proctor Density as specified

F To Footings m2

G To Slab on Ground Incl. slab guard room m2

H To Tank Foundation m2

J To Tie Beam m2

Sandfill 100mm thick as specified

K To Footings m2

L To Slab on Ground Incl. slab guard room m2

M To Tank Foundation m2

N To Tie Beam m2

31.2.4 TERMITE CONTROL

Termite control to soil; The protection against termites by spraying an


insecticide on the soil or on the fill before placing the vapor and after
building completed and importing landfill; undertaken by an approved
specialist; (5 years quarantee to be given) as specified.

O To Footings m2

P To Slab on Ground Incl. slab guard room m2

Q To Tank Foundation m2

R To Wall m2

TA2459 Lesaffre Garuda 4/21 e783-50c7-d64b-56dd-2.2


Item BILL NO. 31 Qty Unit Rate Rupiahs
31.2 EARTHWORK
No. MOLASSES STORAGE

To Collection Rp. -

31.2.5 OTHERS

Plastic sheet

A To Footings m2

B To Slab on Ground Incl. slab guard room m2

C To Tank Foundation m2

D To Tie Beam m2

To Collection Rp. -

COLLECTIONS

Page 31.2 /1

Page 31.2 /2 -

31.2 EARTHWORK

TA2459 Lesaffre Garuda 5/21 e783-50c7-d64b-56dd-2.2


Item BILL NO. 31 Qty Unit Rate Rupiahs
31.2 EARTHWORK
No. MOLASSES STORAGE

CARRIED TO SUMMARY AT END OF BILL NO. 31 Rp. -

TA2459 Lesaffre Garuda 6/21 e783-50c7-d64b-56dd-2.2


Item BILL NO. 31
31.3 CONCRETE Qty. Unit Rate Rupiahs
No. MOLASSES STORAGE

31.3.1 FORMWORK

31.3.1.1 IN GROUND FORMWORK

The design, certification, construction and performance of the formwork,


falsework and backpropping shall be the responsibilty of Contractor.
Proposed method of installation and removal of formwork is to be
submitted to the Superintendent for comment prior to work being carried
out as per dwg note.
In ground formwork as follows; permanent formwork system for in-place
concrete, concrete hollow block 100mm thick, finish starting at/from any
level and including rebates or grooves formers as described to

A To Footings m2 -

B To Slab on Ground m2 -

31.3.1.2 UPPER STRUCTURE FORMWORK

Smooth-Formed Finished concrete, plywood, metal, or other approved


panel materials, finish starting at/from any level and rebates or groove
formers as specified

C To Slab m2 -

D To Tank Foundation m2 -

E To Tie Beam and Beam m2 -

F To Column m2 -

G To Wall Incl. bundwall m2 -

H To Stair m2 -

31.3.2 CONCRETE

In-Situ Concrete

In-situ concrete designed mix Grade 30 Mpa, (K-350) NFA; ± 20mm


aggregate, vibrated with standard flatness as described ;

I To Footings m3 -

J To Slab on Ground Incl. slab guard room m3 -

K To Tank Foundation m3 -

L To Tie Beam and Beam m3 -

M To Column m3 -

N To Wall Incl. bundwall m3 -

O To Stair m3 -

TA2459 Lesaffre Garuda 7/21 e783-50c7-d64b-56dd-2.3


Item BILL NO. 31
31.3 CONCRETE Qty. Unit Rate Rupiahs
No. MOLASSES STORAGE

To Collection Rp. -

31.3.2 CONCRETE, CONT'D

Lean Concrete

Plain in-situ concrete, designed mix grade f'c= Mpa,(K-125), 40mm


aggregate, 50mm thick as described,

A To Footings m2 -

B To Slab on Ground m2 -

C To Tank Foundation m2 -

D To Tie Beam m2 -

31.3.3 REINFORCEMENT

Manufacture reinforcement bars is according to "Manual of Standard


Practice" CRSI's as follows; supply, cleaned, measurement, positioning,
setting and install. Reinforcement measure include joint dowel bars,
bolsters, chairs, spacers and other device for spacing, supporting and
fastening reinforcing bars and welded wire reinforcement in place.

Wiremesh M8-150 as specified

E To Slab on Ground 2 layers m2 -

F To Stair - Bordes slab 2 layers m2 -

Reinforcing bars is Grade 60/420 deformed or Grade BJTD 40 deformed.


round mild steel, as described in

G Dia. 13mm, To Footings kg -

H Dia. 10mm, To Slab on Ground Incl. slab guard room kg -

I Dia. 22mm, To Tank Foundation kg -

J Dia. 13mm, To Tie Beam and Beam kg -

K Dia. 10mm, To Tie Beam and Beam kg -

L Dia. 13mm, To Column kg -

M Dia. 10mm, To Column kg -

N Dia. 10mm, To Wall Incl. bundwall kg -

O Dia. 8mm, To Wall Incl. bundwall kg -

P Dia. 13mm, To Stair kg -

Q Dia. 10mm, To Stair kg -

TA2459 Lesaffre Garuda 8/21 e783-50c7-d64b-56dd-2.3


Item BILL NO. 31
31.3 CONCRETE Qty. Unit Rate Rupiahs
No. MOLASSES STORAGE

To Collection Rp. -

COLLECTIONS

Page 31.3 /1 -

Page 31.3 /2 -

TA2459 Lesaffre Garuda 9/21 e783-50c7-d64b-56dd-2.3


Item BILL NO. 31
31.3 CONCRETE Qty. Unit Rate Rupiahs
No. MOLASSES STORAGE

31.3 CONCRETE
CARRIED TO SUMMARY AT END OF BILL NO. 31 Rp. -

TA2459 Lesaffre Garuda 10/21 e783-50c7-d64b-56dd-2.3


Item BILL NO. 31
31.4 MASONRY Qty. Unit Rate Rupiahs
No MOLASSES STORAGE

31.4.1 UNIT MASONRY


Supply and Install Autoclaved aerated concrete block wall with mortar;
including reinforced concrete bonding ties, anchorage, latching, stiffener
columns and lintels beams as required, all in accordancce with drawings
and specifications

A To Wall 150mm thick External Wall m2

B To Wall 150mm thick Internal Wall m2

31.4.2 PLASTERED

Plaster; Mortar instant trowelled smooth with and including cement coating
instant as described

C To Wall 150mm thick m2 -

31.4 MASONRY
CARRIED TO SUMMARY AT END OF BILL NO. 31 Rp. -

TA2459 Lesaffre Garuda 11/21 e783-50c7-d64b-56dd-2.4


Item BILL NO. 31 31.5 METALS
Qty. Unit Rate Rupiahs
No MOLASSES STORAGE

31.5.1 RAILING

Supply and Install steel pipe railing including handrail support and knee
railing complete with kick plate, anchor bolt and all necessary fixing
accessories as drawings and specifications

A To stair m

31.5.2 SUNDRIES

Supply and install hot dipped galvanized steel angle complet with all
fixing accessories and support as drawing and specification

B L 50.50.5 m

Supply and install steel grating complete with metal angle support
grating including all fixing accessories and support as drawing and

C To Gutter m

D To Sumpit 600x600mm nos

E To Sumpit 1000x1000mm nos

31.5 METALS
CARRIED TO SUMMARY AT END OF BILL NO. 31 Rp. -

TA2459 Lesaffre Garuda 12/21 e783-50c7-d64b-56dd-2.5


Item BILL NO. 31 31.5 METALS
Qty. Unit Rate Rupiahs
No MOLASSES STORAGE

TA2459 Lesaffre Garuda 13/21 e783-50c7-d64b-56dd-2.5


Item BILL NO. 31 31.7 THERMAL AND MOISTURE Qty Unit Rate Rupiahs
No. MOLASSES STORAGE PROTECTION

31.7.1 ROOF SPECIALITIES

Supply and Install down pipe complete with overflow, steel clamp, support,
fitting, bracket, steel unp, and all fixing accessories; all in accordance with
drawings and specifications

A PVC Downpipe Ø4" m

B Roof Drain nos

Supply and install concrete waterproofing liquid membrane complete with


screeding, accessories and support; all in accordance with manufacturer's
instruction, drawings, and specifications

C To Roof m2

31.7 THERMAL AND MOISTURE PROTECTION


CARRIED TO SUMMARY AT END OF BILL NO. 31 Rp. -

TA2459 Lesaffre Garuda 14/21 e783-50c7-d64b-56dd-2.7


Item BILL NO. 31
31.8 DOORS AND WINDOWS Qty. Unit Rate Rupiahs
No. MOLASSES STORAGE

31.8.1 DOORS

Supply and install aluminium door including laminated tempered glass +


clear glass, frames, hardwares, treshold, steel plate, and all fixing
accessories and supports as drawings and specifications

A 31.DR.001 nos

31.8.3 WINDOWS

Supply and install aluminium window complete with laminated tempered


glass + clear glass, hardwares, and all necessary components, fixing,
accessories as drawing and specification.

B 31.WA.001 nos

C 31.WB.002 nos

D 31.WB.003 nos

31.8 DOORS AND WINDOWS


CARRIED TO SUMMARY AT END OF BILL NO. 31 Rp. -

TA2459 Lesaffre Garuda 15/21 e783-50c7-d64b-56dd-2.8


Item BILL NO. 31
31.9. FINISHES Qty. Unit Rate Rupiahs
No MOLASSES STORAGE

31.9.1 FLOOR FINISHES

Epoxy; all in accordance with manufacturer's instruction, drawings, and


specifications

A To Floor m2

Supply and install Homogenous Tile complete with screed, gape grouting
and all in accordance with manufactured instruction applied: all in
accordance with drawings and specifications

B To Floor m2

C To Skirting m

Concrete Broom Finish; all in accordance with manufacturer's instruction,


drawings, and specifications

D To Floor m2

31.9.2 WALL FINISHES

Prepare smooth and apply epoxy paint finish, in accordance with


manufacturer's recommendations, as specified to face of :

E Applied to concrete walls m2

Prepare smooth and apply waterbased acrylic emulsion paint finish, in


accordance with manufacturer's recommendations, as specified to face of :

F Applied to plastered autoclaved concrete walls (Internal Wall) m2

Prepare smooth and apply waterbased wethershield emulsion paint finish,


in accordance with manufacturer's recommendations, as specified to face of

G Applied to plastered autoclaved concrete walls (External Wall) m2

H Applied to parapet wall

Prepare smooth and apply skimcoat, in accordance with manufacturer's


recommendations, as drawing and specification

I Applied to concrete walls m2

31.9.3 CEILING FINISHES

Prepare smooth and apply waterbased acrylic emulsion paint finish, in


accordance with manufacturer's recommendations, as specified to face of :

J To Concrete Ceiling m2

Prepare smooth and apply skimcoat, in accordance with manufacturer's


recommendations, as drawing and specification

K To Concrete Ceiling m2

31.9. FINISHES
CARRIED TO SUMMARY AT END OF BILL NO. 31 Rp. -

TA2459 Lesaffre Garuda 16/21 e783-50c7-d64b-56dd-2.9


Item BILL NO. 31
31.10 SPECIALITIES Qty. Unit Rate Rupiahs
No MOLASSES STORAGE

31.10 SPECIALITIES
CARRIED TO SUMMARY AT END OF BILL NO. 31 Rp. N/A

TA2459 Lesaffre Garuda 17/21 e783-50c7-d64b-56dd-2.10


Item BILL NO. 31
31.11 MECHANICAL WORKS Qty. Unit Rate Rupiahs
No MOLASSES STORAGE

31.11 MECHANICAL WORKS


CARRIED TO SUMMARY AT END OF BILL NO. 31 Rp. N/A

TA2459 Lesaffre Garuda 18/21 e783-50c7-d64b-56dd-2.11


Item BILL NO. 31
31.2 ELECTRICAL WORKS Qty. Unit Rate Rupiahs
No MOLASSES STORAGE

31.12 ELECTRICAL WORKS

31.12.1 SUB DISTRIBUTION BOARDS


Supply, Install and Testing Commissioning the following Sub Distribution board
fix in position includes circuit breaker, board, busbar, digital multimeter,
contactor, surge arrester, potensial transformer, current transformer, indicator
lamp, fuse, loto, star / stop push button, and all necessary accessories in
arcondance to the technical spesification as shown on drawing, as described : -

A 31DB01 no

31.12.2 MAIN AND SUB-MAINS CABLES


Supply and Install the following Main and Sub-Mains circuit distribution cable
run & fixed on cable tray/ladders including all necessary accessories in
arcondance to the technical spesification as shown on drawing, as described : -

B From SDB…. to 31DB01 m by other package

31.12.3 LIGHTING FIXTURES & POWER OUTLET


Supply and Install the following light fittings including tubes or lamps fixed in
position complete with all accessories and support in accordance with the
technical specification and drawings, as described :-

C Waterproof LED 40W, 220V, IP65 mounted on steel pipe 2.5m height Ø50mm no

D Flood light LED 100W, 9500lm, mounted on steel pipe 2.5m height Ø50mm no

E Surface downlight 16W, 220V, minimum 1.200lm no

Supply and Install the following switches including provision of steel/metal box
and all accessories accordance with the technical specification and drawings, as
described :-

F Double gang, 1 way switch, 10A no

Supply and Install lighting & switch cables from sub circuit to final circuit
including grounding system and all neccessary accessories accordance with the
technical specification and drawings, as described :-

G Cabling point from local panel (NYM 3C x 2.5 mm² run-in and with PVC high no
impact conduit) to; lighting and switch

POWER OUTLET
Supply and Install the following power outlet including provision of steel/metal
box and all accessories accordance with the Technical Specification and
drawings, as described :-

H General socket outlet, wall mounted, 16A, 250V, single gang no

I Industrial socket outlet, mounted on the front panel door, 16A, 250V, IP65 no

J Industrial socket outlet, mounted on the front panel door, 32A, 400V, IP65

To Collection Rp. -

TA2459 Lesaffre Garuda 19/21 e783-50c7-d64b-56dd-2.12


Item BILL NO. 31
31.2 ELECTRICAL WORKS Qty. Unit Rate Rupiahs
No MOLASSES STORAGE

21.12.4 TRAYS AND LADDERS


Supply and Install hot dip galvanized tray and ladder 2mm thickness include
jointing, elbow, tee, fixing accessories and hangers and all necessary accessories
accordance with the technical specification and drawings, as described :-

Electrical

A Cable tray 300x100mm m

B Wiremesh tray 300x100mm m

C Wiremesh tray 200x100mm m

21.12.5 GROUNDING & LIGHTNING PROTECTION SYSTEM

Supply and Install Grounding system for panel and equipment complete with
support and all neccessary accessories accordance with the technical
specification and drawings, as described :-

D Earth pit, Conductor clamp and rod electrode, dia 19mm x 3000 length no

E Earthing bonding bar (copper bar) 40x3mm thk, c/w isolator no

F BC 70mm2, grounding cable for main/mesh earthing c/w connector and m


grounding lug

To Collection Rp. -

COLLECTIONS

Page 31.12 /1 -

Page 31.12 /2 -

31.2 ELECTRICAL WORKS


CARRIED TO SUMMARY AT END OF BILL NO. 31 Rp. -

TA2459 Lesaffre Garuda 20/21 e783-50c7-d64b-56dd-2.12


Item BILL NO. 31
31.3 HVAC WORKS Qty. Unit Rate Rupiahs
No MOLASSES STORAGE

31.3 HVAC WORKS


CARRIED TO SUMMARY AT END OF BILL NO. 31 Rp. N/A

TA2459 Lesaffre Garuda 21/21 e783-50c7-d64b-56dd-2.13


BILL NO. 40
YEAST CREAM PRODUCTION

TA2459 Lesaffre Garuda 1/60 69ee-c99f-6b5d-bd85-Cover


Item BILL NO. 40 SUMMARY RUPIAHS
No. YEAST CREAM PRODUCTION

SUMMARY

40.1 DEMOLITION N/A

40.2 EARTHWORK -

40.3 CONCRETE -

40.4 MASONRY -

40.5 METALS -

40.7 THERMAL AND MOISTURE PROTECTION -

40.8 DOORS AND WINDOWS -

40.9. FINISHES -

40.10 SPECIALITIES -

40.11 MECHANICAL WORKS -

40.2 ELECTRICAL WORKS -

40.3 HVAC WORKS -

BILL NO. 40
CARRIED TO SUMMARY -

TA2459 Lesaffre Garuda 2/60 69ee-c99f-6b5d-bd85-Sum


Item BILL NO. 40 Qty Unit Rate Rupiahs
40.2 EARTHWORK
No. YEAST CREAM PRODUCTION

40.2.1 CUT OFF PILE HEAD

Cut off pile head as drawings

A Spun pile, dia. 400mm nos

40.2.2 EARTHWORK

Excavation, disposal and backfill in any material including rock or hard


material, working space at parimeter items as defined; Excavating, starting
from stripped level, trenches to receive depth as pecified (insite area)

B To Pile Caps m3

C To Slab on Ground Incl. Ramp m3

D To Plinths/Tank Foundation m3

E To Pedestal m3

40.2.3 BASE COURSES

Compacted of subgrade to 95% Standard Proctor Density as specified

F To Pile Caps m2

G To Slab on Ground Incl. Ramp m2

H To Plinths/Tank Foundation m2

I To Tie Beam m2

Sandfill 100mm thick as specified

J To Pile Caps m2

K To Slab on Ground Incl. Ramp m2

L To Plinths/Tank Foundation m2

M To Tie Beam m2

40.2.4 TERMITE CONTROL

Termite control to soil; The protection against termites by spraying an


insecticide on the soil or on the fill before placing the vapor and after
building completed and importing landfill; undertaken by an approved
specialist; (5 years quarantee to be given) as specified.

N To Pile Caps m2

O To Slab on Ground Incl. Ramp m2

P To Plinths/Tank Foundation m2

Q To Pedestal m2

TA2459 Lesaffre Garuda 3/60 69ee-c99f-6b5d-bd85-2.2


Item BILL NO. 40 Qty Unit Rate Rupiahs
40.2 EARTHWORK
No. YEAST CREAM PRODUCTION

To Collection Rp. -

40.2.5 OTHERS

Plastic sheet

A To Pile Caps m2

B To Slab on Ground Incl. Ramp m2

C To Plinths/Tank Foundation m2

D To Tie Beam m2

To Collection Rp. -

COLLECTIONS

Page 40.2 /1

Page 40.2 /2 -

TA2459 Lesaffre Garuda 4/60 69ee-c99f-6b5d-bd85-2.2


Item BILL NO. 40 Qty Unit Rate Rupiahs
40.2 EARTHWORK
No. YEAST CREAM PRODUCTION

40.2 EARTHWORK
CARRIED TO SUMMARY AT END OF BILL NO. 40 Rp. -

TA2459 Lesaffre Garuda 5/60 69ee-c99f-6b5d-bd85-2.2


Item BILL NO. 40
40.3 CONCRETE Qty. Unit Rate Rupiahs
No. YEAST CREAM PRODUCTION

40.3.1 FORMWORK

40.3.1.1 IN GROUND FORMWORK

The design, certification, construction and performance of the formwork,


falsework and backpropping shall be the responsibilty of Contractor.
Proposed method of installation and removal of formwork is to be
submitted to the Superintendent for comment prior to work being carried
out as per dwg note.
In ground formwork as follows; permanent formwork system for in-place
concrete, concrete hollow block 100mm thick, finish starting at/from any
level and including rebates or grooves formers as described to

A To Pile Caps m2 -

B To Slab on Ground Incl. Ramp m2 -

C To Gutter m2 -

40.3.1.2 UPPER STRUCTURE FORMWORK

Smooth-Formed Finished concrete, plywood, metal, or other approved


panel materials, finish starting at/from any level and rebates or groove
formers as specified

D To Upper Slab m2 -

E To Tank Foundation m2 -

F To Tie Beam and Beam m2 -

G To Pedestal m2 -

H To Wall/Parapet Incl. bundwall m2 -

I To Stair m2 -

J To Gutter m2 -

Metal Deck BMT 0.7 thick including shear connector, support and all
necessary as drawing specified

K To Floor m2 -

40.3.2 CONCRETE

In-Situ Concrete

In-situ concrete designed mix Grade 30 Mpa, (K-350) NFA; ± 20mm


aggregate, vibrated with standard flatness as described ;

L To Pile Caps m3 -

M To Slab on Ground m3 -

N To Plinth/Tank Foundation m3 -

O To Tie Beam and Beam m3 -

TA2459 Lesaffre Garuda 6/60 69ee-c99f-6b5d-bd85-2.3


Item BILL NO. 40
40.3 CONCRETE Qty. Unit Rate Rupiahs
No. YEAST CREAM PRODUCTION

To Collection Rp. -

40.3.2 CONCRETE, CONT'D

In-Situ Concrete

In-situ concrete designed mix Grade 30 Mpa, (K-350) NFA; ± 20mm


aggregate, vibrated with standard flatness as described ;

A To Pedestal m3 -

B To Wall/Parapet m3 -

C To Stair m3 -

D To Gutter m3 -

Lean Concrete

Plain in-situ concrete, designed mix grade f'c= Mpa,(K-125), 40mm


aggregate, 50mm thick as described,

E To Pile Caps m2 -

F To Slab on Ground m2 -

G To Plinth/Tank Foundation m2 -

H To Tie Beam m2 -

40.3.3 REINFORCEMENT

Manufacture reinforcement bars is according to "Manual of Standard


Practice" CRSI's as follows; supply, cleaned, measurement, positioning,
setting and install. Reinforcement measure include joint dowel bars,
bolsters, chairs, spacers and other device for spacing, supporting and
fastening reinforcing bars and welded wire reinforcement in place.

Wiremesh M8-150 as specified

I To Upper Slab 2 layers m2 -

Reinforcing bars is Grade 60/420 deformed or Grade BJTD 40 deformed.


round mild steel, as described in

J Dia. 19mm, To Pile Caps kg -

K Dia. 16mm, To Pile Caps kg -

L Dia. 13mm, To Pile Caps kg -

M Dia. 10mm, To Pile Caps kg -

N Dia. 19mm, To Slab on Ground Incl. Ramp kg -

O Dia. 13mm, To Slab on Ground Incl. Ramp kg -

P Dia. 25mm, To Tie Beam and Beam kg -

TA2459 Lesaffre Garuda 7/60 69ee-c99f-6b5d-bd85-2.3


Item BILL NO. 40
40.3 CONCRETE Qty. Unit Rate Rupiahs
No. YEAST CREAM PRODUCTION

To Collection Rp. -

40.3.3 REINFORCEMENT

Reinforcing bars is Grade 60/420 deformed or Grade BJTD 40 deformed.


round mild steel, as described in

A Dia. 19mm, To Tie Beam and Beam kg -

B Dia. 10mm, To Tie Beam and Beam kg -

C Dia. 19mm, To Pedestal kg -

D Dia. 16mm, To Pedestal kg -

E Dia. 10mm, To Pedestal kg -

F Dia. ..mm, To Wall/Parapet Incl. bundwall kg -

G Dia. ..mm, To Wall/Parapet Incl. bundwall kg -

H Dia. ..mm, To Stair kg -

I Dia. ..mm, To Stair kg -

J Dia. ...mm, To Plinths/Tank Foundation kg -

K Dia. ...mm, To Plinths/Tank Foundation kg -

L Dia. ...mm, To Plinths/Tank Foundation kg -

M Dia. ...mm, To Gutter kg -

N Dia. ...mm, To Gutter kg -

To Collection Rp. -

COLLECTIONS

Page 40.3 /1 -

Page 40.3 /2 -

Page 40.3 /3 -

TA2459 Lesaffre Garuda 8/60 69ee-c99f-6b5d-bd85-2.3


Item BILL NO. 40
40.3 CONCRETE Qty. Unit Rate Rupiahs
No. YEAST CREAM PRODUCTION

40.3 CONCRETE
CARRIED TO SUMMARY AT END OF BILL NO. 40 Rp. -

TA2459 Lesaffre Garuda 9/60 69ee-c99f-6b5d-bd85-2.3


Item BILL NO. 40
40.4 MASONRY Qty. Unit Rate Rupiahs
No YEAST CREAM PRODUCTION

40.4.1 UNIT MASONRY

Supply and Install Autoclaved aerated concrete block wall with mortar;
including reinforced concrete bonding ties, anchorage, latching, stiffener
columns and lintels beams as required, all in accordancce with drawings
and specifications

A To Wall 150mm thick External Wall m2

B To Wall 150mm thick Internal Wall m2

C To Wall 150mm thick Fire Rated m2

40..4.2 PLASTERED

Plaster; Mortar instant trowelled smooth with and including cement coating
instant as described

D To Wall 150mm thick m2

40.4.3 WALL PARTITION

Supply and Install Metal cladding 0.45 BMT finish colorbond fixed to
steel structure, including sealant, and all necessary fixing accessories; all in
accordance with drawings and specifications

E To Wall m2

Supply and install PIR Sandwich Panel including Coving and all necessary
fixing accessories and steel support; all in accordance with drawings and
specifications

F To Wall - 150mm thick m2

Supply and install Rockwool 60kg/m3 complete with Glass Cloth and
Perporated Accoustic Gypsumboard including metal stud, and all necessary
fixing accessories and support; all in accordance with drawings and
specifications

G To Wall m2

40.4.3 CEILING PARTITION

Supply and install calsium silicate board 6mm glued in gypsum ceiling
including ceiling suspension system and fixing accessories all in accordance
with drawings and specifications

H To Ceiling m2 -

40.4 MASONRY
CARRIED TO SUMMARY AT END OF BILL NO. 40 Rp. -

TA2459 Lesaffre Garuda 10/60 69ee-c99f-6b5d-bd85-2.4


Item BILL NO. 40 40.5 METALS
Qty. Unit Rate Rupiahs
No YEAST CREAM PRODUCTION

40.5.1 STRUCTURAL FRAMING

The following in steel structure in framing sanblasting and painting


finished ; from ground level to roof floor level; comprising wide flange
bolted to mild steel, cleats, welded to rafter; including all labour,
materials and plant in fabricating,erecting with welded and bolted shop
and site connections; assembling and erecting with welded and bolted
shop and site connections; and all necessaries as specified on
specification and drawing; steel grade as note on specifications ( ASTM
A-36 / BJ 37 for steel structure)
A SC4 WF200x200x8x12 kg -

B SC6, WF250x250x9x14 kg -

C SC8, WF300x300x10x15 kg -

D SC10, WF350x350x12x19 kg -

E SC12, WF400x400x13x21 kg -

F SC21, UNP200x90 kg -

G PR3, C150x65x20x2.3 kg -

H PR4, C150x65x20x3.2 kg -

I PR5, C200x75x20x2.3 kg -

J PR8, Z20024 kg -

K PR9, Z15024 kg -

L R3, WF250x125x6x9-R kg -

M R4, WF300x150x6.5x9-R kg -

N R6, WF400x200x8x13-R kg -

O HB17, Dia16-HB kg -

P HB18, Dia19-HB kg -

Q SB2, WF200x100x5.5x8-SB kg -

R SB3, WF250x125x6x9-SB kg -

S SB4, WF300x150x6.5x9-SB kg -

T SB5, WF350x175x7x11-SB kg -

U SB6, WF400x200x8x13-SB kg -

V SB12, UNP150x75-SB kg -

W SB14, UNP200x90-SB kg -

X SG3, WF250x125x6x9-SG kg -

Y SG4, WF300x150x6.5x9-SG kg -

TA2459 Lesaffre Garuda 11/60 69ee-c99f-6b5d-bd85-2.5


Item BILL NO. 40 40.5 METALS
Qty. Unit Rate Rupiahs
No YEAST CREAM PRODUCTION

To Collection Rp. -

40.5.1 STRUCTURAL FRAMING, CONT'D

The following in steel structure in framing sanblasting and painting


finished ; from ground level to roof floor level; comprising wide flange
bolted to mild steel, cleats, welded to rafter; including all labour,
materials and plant in fabricating,erecting with welded and bolted shop
and site connections; assembling and erecting with welded and bolted
shop and site connections; and all necessaries as specified on
specification and drawing; steel grade as note on specifications ( ASTM
A-36 / BJ 37 for steel structure)
A SG5, WF350x175x7x11-SG kg -

B SG6, WF400x200x8x13-SG kg -

C SG7, WF450x200x9x14-SG kg -

D TR2, Dia12-TR kg -

E VB2, L50x50x6-VB2 kg -

F All connecting plates, brackets, cleats, bolts, anchor bolts and stiffeners, Ls -
welding, including sandblasting and painted finish and all necessary
fixing accessories as described

40.5.2 CAGE LADDER

Supply and install cage ladder including landing step, connecting plates
and all fixing accessories and support as drawing and specification

G Cage ladder - 3rd Floor nos

H Cage ladder - 4th Floor nos

I Cage ladder - 5th Floor nos

40.5.3 RAILINGS

Supply and Install Stainless steel pipe railing including handrail support
and knee railing complete with kick plate, anchor bolt and all necessary
fixing accessories as drawings and specifications

J To Platform and Ingredients Preparation Mezzanine m

Supply and Install Galvanized steel pipe railing including handrail


support and knee railing complete with kick plate, anchor bolt and all
necessary fixing accessories as drawings and specifications

K To Commercial Cream Storage Mezzanine and Roof m

40.5.4 OTHERS

L Supply and install galvanized steel grating 32mm thick including all m2 -
support and accessories per drawings and specifications

M Supply and install galvanized steel grating 30mm thick including all m2 -
support and accessories per drawings and specifications

TA2459 Lesaffre Garuda 12/60 69ee-c99f-6b5d-bd85-2.5


Item BILL NO. 40 40.5 METALS
Qty. Unit Rate Rupiahs
No YEAST CREAM PRODUCTION

To Collection Rp. -

40.5.4 OTHERS, CONT'D

Supply and install steel grating complete with metal angle support grating
including all fixing accessories and support as drawing and specification

A To Floor m2

B To Gutter m2

Supply and install steel bollard including baseplate and all fixing
accessories and support as drawing and specification

C Steel Bollard nos

To Collection Rp. -

COLLECTIONS

Page 40.5 /1 -

Page 40.5 /2 -

Page 40.5 /3 -

TA2459 Lesaffre Garuda 13/60 69ee-c99f-6b5d-bd85-2.5


Item BILL NO. 40 40.5 METALS
Qty. Unit Rate Rupiahs
No YEAST CREAM PRODUCTION

40.5 METALS
CARRIED TO SUMMARY AT END OF BILL NO. 40 Rp. -

TA2459 Lesaffre Garuda 14/60 69ee-c99f-6b5d-bd85-2.5


Item BILL NO. 40 40.7 THERMAL AND MOISTURE Qty Unit Rate Rupiahs
No. YEAST CREAM PRODUCTION PROTECTION

40.7.1 FLASHING AND SHEET METAL

Supply and Install metal roof Klip Lok 0.45 BMT fixed to steel purlin
including sealant, and all fixing accessories; all in accordance with
drawings and specifications

A To Roof m2

Supply and Install Waterstop Colorbond finish fixed to metal roof sheet,
including sealant and all necessary fixing accessories; all in accordance with
drawings and specifications

B To Roof m

Supply and Install Metal cladding Trimdek 0.45 BMT finish colorbond
fixed to steel structure, including sealant, over flow galvanized steel pipe
Ø2" 6000mm CTC, and all necessary fixing accessories; all in accordance
with drawings and specifications

C To Fascia m2

Supply and Install Metal Flashing 0.45 BMT precoated finish colorbond
fixed to steel purlin, including sealant and all necessary fixing accessories;
all in accordance with drawings and specifications

D To Fascia m

40.7.2 ROOF SPECIALITIES

Supply and install PIR Sandwich Panel including Coving and all necessary
fixing accessories and steel support; all in accordance with drawings and
specifications

E To Roof, 75mm thick m2

F To Fascia, 75mm thick m2

Supply and Install metal gutter 0.5mm with weatherproof sealant complete
with plate support, jointing and all necessary fixing accessories and support,
in accordance with manufacturer's recommendations, as drawings and
specifications

G To Roof Gutter m2

Supply and Install down pipe complete with overflow, steel clamp, support,
fitting, bracket, steel unp, and all fixing accessories; all in accordance with
drawings and specifications

H PVC Downpipe Ø4" m

I Roof Drain nos

Supply and install concrete waterproofing liquid membrane including


sreeding, accessories and support; all in accordance with manufacturer's
instruction, drawings, and specifications

J To Roof m2

TA2459 Lesaffre Garuda 15/60 69ee-c99f-6b5d-bd85-2.7


Item BILL NO. 40 40.7 THERMAL AND MOISTURE Qty Unit Rate Rupiahs
No. YEAST CREAM PRODUCTION PROTECTION

To Collection Rp. -

40.7.3 SUNDRIES

A Supply and Install Balustrade as drawings and specifications m

B Waterdrip 10mm as drawings and specifications m

C Supply and Install Turbin Ventilator complete with all fixing accessories nos
and support as drawings and specifications

To Collection Rp. -

COLLECTIONS

Page 40.7 / 1

Page 40.7 / 2

40.7 THERMAL AND MOISTURE PROTECTION


CARRIED TO SUMMARY AT END OF BILL NO. 40 Rp. -

TA2459 Lesaffre Garuda 16/60 69ee-c99f-6b5d-bd85-2.7


Item BILL NO. 40
40.8 DOORS AND WINDOWS Qty. Unit Rate Rupiahs
No. YEAST CREAM PRODUCTION

40.8.1 DOORS

Supply and install High Speed Door including frames, hardwares, treshold,
steel plate, and all necessary accessories and fixing supports as drawings
and specifications

A 40.DA.002 nos

B 40.DA.004 nos

C 40.DA.006 nos

D 40.DA.010 nos

E 40.DA.012 nos

Supply and install Sectional Door including , frames, hardwares, treshold,


steel plate, and all fixing accessories and supports as drawings and
specifications

F 40.DB.001 nos

Supply and install Fire Shutter Door including , frames, hardwares,


treshold, steel plate, and all fixing accessories and supports as drawings and
specifications

G 40.DD.007 nos

Supply and install Steel Rolling Door including , frames, hardwares,


treshold, steel plate, and all fixing accessories and supports as drawings and
specifications

H 40.DE.014 nos

Supply and install steel door including vision panel / louvre, frames,
hardwares, treshold, steel plate, and all fixing accessories and supports as
drawings and specifications

I 40.DF.016 nos

J 40.DF.018 nos

K 40.DG.017 nos

L 40.DH.028 nos

M 40.DL.009 nos

N 40.DL.013 nos

A 40.DL.030 nos

B 40.DL.037 nos

C 40.DL.038 nos

D 40.DL.039 nos

E 40.DN.003 nos

TA2459 Lesaffre Garuda 17/60 69ee-c99f-6b5d-bd85-2.8


Item BILL NO. 40
40.8 DOORS AND WINDOWS Qty. Unit Rate Rupiahs
No. YEAST CREAM PRODUCTION

To Collection Rp. -

40.8.1 DOORS, CONT'D

Supply and install alumnium door including vision panel / louvre, frames,
hardwares, treshold, steel plate, and all fixing accessories and supports as
drawings and specifications

A 40.DK.019 nos

B 40.DK.029 nos

C 40.DP.020 nos

D 40.DQ.023 nos

E 40.DQ.024 nos

F 40.DQ.025 nos

G 40.DQ.026 nos

H 40.DQ.027 nos

I 40.DR.005 nos

J 40.DR.011 nos

K 40.DR.021 nos

L 40.DR.022 nos

M 40.DR.031 nos

N 40.DR.034 nos

O 40.DR.035 nos

P 40.DR.036 nos

Supply and install alumnium glass door including vision panel / louvre,
frames, hardwares, treshold, steel plate, and all fixing accessories and
supports as drawings and specifications

Q 40.DU.032 nos

R 40.DU.033 nos

Supply and install steel fire rated door including vision panel / louvre,
frames, hardwares, treshold, steel plate, and all fixing accessories and
supports as drawings and specifications

S 40.DV.008 nos

T 40.DV.015 nos

TA2459 Lesaffre Garuda 18/60 69ee-c99f-6b5d-bd85-2.8


Item BILL NO. 40
40.8 DOORS AND WINDOWS Qty. Unit Rate Rupiahs
No. YEAST CREAM PRODUCTION

To Collection Rp. -

40.8.2 WINDOWS

Supply and install aluminium window complete with laminated tempered


glass + clear glass, hardwares, and all necessary components, fixing,
accessories as drawings and specifications

A 40.WA.005 nos

B 40.WB.001 nos

C 40.WB.002 nos

D 40.WB.003 nos

E 40.WB.004 nos

F 40.WB.006 nos

G 40.WB.007 nos

40.8.3 LOUVRES

Supply and install steel louvre complete with removable insect screen,
hardwares, and all necessary components, fixing, accessories as drawing
and specification.

H 40.LA.001 nos

I 40.LA.002 nos

J 40.LA.003 nos

K 40.LA.004 nos

L 40.LA.005 nos

M 40.LA.006 nos

N 40.LA.007 nos

O 40.LA.008 nos

P 40.LA.009 nos

Q 40.LA.010 nos

R 40.LA.011 nos

S 40.LA.012 nos

T 40.LA.013 nos

U 40.LA.014 nos

V 40.LA.015 nos

TA2459 Lesaffre Garuda 19/60 69ee-c99f-6b5d-bd85-2.8


Item BILL NO. 40
40.8 DOORS AND WINDOWS Qty. Unit Rate Rupiahs
No. YEAST CREAM PRODUCTION

W 40.LA.016 nos

X 40.LA.017 nos

To Collection Rp. -

40.8.3 LOUVRES, CONT'D

Supply and install steel louvre complete with removable insect screen,
hardwares, and all necessary components, fixing, accessories as drawing
and specification.

A 40.LA.018 nos

B 40.LA.019 nos

C 40.LA.020 nos

D 40.LA.021 nos

E 40.LA.022 nos

F 40.LA.023 nos

G 40.LA.024 nos

H 40.LA.025 nos

I 40.LA.026 nos

40.8.4 CURTAIN WALL

Supply and install curtain wall system complete with hardwares, and all
necessary components, fixing, accessories as drawing and specification

A 40.SR.001 nos

B 40.SR.002 nos

To Collection Rp. -

COLLECTIONS

Page 40.8 /1 -

Page 40.8 /2 -

TA2459 Lesaffre Garuda 20/60 69ee-c99f-6b5d-bd85-2.8


Item BILL NO. 40
40.8 DOORS AND WINDOWS Qty. Unit Rate Rupiahs
No. YEAST CREAM PRODUCTION

Page 40.8 /3 -

Page 40.8 /4 -

40.8 DOORS AND WINDOWS


CARRIED TO SUMMARY AT END OF BILL NO. 40 Rp. -

TA2459 Lesaffre Garuda 21/60 69ee-c99f-6b5d-bd85-2.8


Item BILL NO. 40
40.9. FINISHES Qty. Unit Rate Rupiahs
No YEAST CREAM PRODUCTION

40.9.1 FLOOR FINISHES

Prepare and apply floor hardener; all in accordance with manufacturer's


instruction, drawings, and specifications

A To Floor m2

Prepare and apply epoxy quartz; all in accordance with manufacturer's


instruction, drawings, and specifications

B To Floor m2

Prepare and apply anti acid/alkali/slippery tile; all in accordance with


manufacturer's instruction, drawings, and specifications

C To Floor m2

D To Skirting H=150mm

Prepare and apply epoxy coating; all in accordance with manufacturer's


instruction, drawings, and specifications

E To Floor m2

Supply and install Homogenous Tile complete with screed, gape grouting
and all in accordance with manufactured instruction applied: all in
accordance with drawings and specifications

F To Floor m2

G To Skirting H=100mm m

Supply and install Homogenous Tile Shock Resistant complete with screed,
gape grouting and all in accordance with manufactured instruction applied:
all in accordance with drawings and specifications

H To Floor m2

I To Skirting H=150mm m

Supply and install raised floor system complete with all fixing accessories
and support; all in accordance with manufactured instruction applied: all in
accordance with drawings and specifications

J To Floor m2

Concrete broom finish; all in accordance with manufactured instruction


applied: all in accordance with drawings and specifications

K To Floor m2

Prepare and apply below materials to skirting wall complete with


accessories and support; all in accordance with manufactured instruction
applied: all in accordance with drawings and specifications

L PU Paint, h=100mm m

M Epoxy Mortar Round Coving R=70mm m

N Hardening, h=100mm m

TA2459 Lesaffre Garuda 22/60 69ee-c99f-6b5d-bd85-2.9


Item BILL NO. 40
40.9. FINISHES Qty. Unit Rate Rupiahs
No YEAST CREAM PRODUCTION

To Collection Rp. -

40.9.2 WALL FINISHES

Prepare smooth and apply epoxy paint finish, in accordance with


manufacturer's recommendations, as specified to face of :

A Applied to concrete walls m2

Prepare smooth and apply waterbased acrylic emulsion paint finish, in


accordance with manufacturer's recommendations, as specified to face of :

B Applied to plastered autoclaved concrete walls (Internal Wall) m2

Prepare smooth and apply waterbased wethershield emulsion paint finish,


in accordance with manufacturer's recommendations, as specified to face of
:

C Applied to plastered autoclaved concrete walls (External Wall) m2

Supply and install Homogenous Tile complete with screed, gape grouting
and all in accordance with manufactured instruction applied: all in
accordance with drawings and specifications

D Applied to autoclaved concrete walls m2

Prepare and apply anti acid/alkali tile with epoxy joint; all in accordance
with manufacturer's instruction, drawings, and specifications

E Applied to autoclaved concrete walls m2

40.9.3 CEILING FINISHES

Prepare smooth and apply waterbased acrylic emulsion paint finish, in


accordance with manufacturer's recommendations, as specified to face of :

F To Calciboard Ceiling m2

G To Exposed Concrete m2

Prepare smooth and apply skimcoat, in accordance with manufacturer's


recommendations, as drawing and specification

H To Exposed Concrete m2

TA2459 Lesaffre Garuda 23/60 69ee-c99f-6b5d-bd85-2.9


Item BILL NO. 40
40.9. FINISHES Qty. Unit Rate Rupiahs
No YEAST CREAM PRODUCTION

To Collection Rp. -

COLLECTIONS

Page 40.9 /1

Page 40.9 /2

TA2459 Lesaffre Garuda 24/60 69ee-c99f-6b5d-bd85-2.9


Item BILL NO. 40
40.9. FINISHES Qty. Unit Rate Rupiahs
No YEAST CREAM PRODUCTION

40.9. FINISHES
CARRIED TO SUMMARY AT END OF BILL NO. 40 Rp. -

TA2459 Lesaffre Garuda 25/60 69ee-c99f-6b5d-bd85-2.9


Item BILL NO. 40
40.10 SPECIALITIES Qty. Unit Rate Rupiahs
No YEAST CREAM PRODUCTION

40.10.1 INTERIOR SPECIALITIES

Supply and install sanitary wares complete with all necessary in


accordance with manufacturer's recommendations as drawing and
specification

A SF1, Stainless steel 304 short station nos

B SF8, Wall mounted nos

C SF9, Toilet Cubicle nos

D SF10, Toilet Seated nos

E SF11, General floor drain nos

F SF12, Jet Shower nos

G SF13, Urinoir nos

H SF14, Urinal Partition nos

I SF15, Automatic Tap nos

J SF16, Self Closing Tap nos

K SF17, Under Counter Lavatory nos

L SF18, Wall Hung Lavatory nos

M SF19, Paper Towel Holder nos

N SF20, Wall Mounted Shower nos

O SF21, Shower Stop Valve nos

P SF22, Mirror Half Body Stainless Steel nos

Q SF23, Mirror Half Body T:5mm nos

R SF24, Soap Dispenser nos

S SF25, Automatic Soap Dispenser nos

T SF27, Automatic Hand Sanitizer Dispenser nos

U SF28, Stainless Steel 304 Paper Towel Dispenser nos

V SF29, Paper Towel Dispenser Plastic Material nos

TA2459 Lesaffre Garuda 26/60 69ee-c99f-6b5d-bd85-2.10


Item BILL NO. 40
40.10 SPECIALITIES Qty. Unit Rate Rupiahs
No YEAST CREAM PRODUCTION

To Collection Rp. -

40.10.2 FURNITURES

Supply and install furnitures complete with all necessary in accordance


with manufacturer's recommendations as drawing and specification

A FU02, Overall Cabinet nos

B FU03, Step Over Bench nos

C FU04, Bench nos

D FU05, Hairnet and Mask Container nos

E FU06, Waste Bin nos

F FU07, Locker nos

G FI08, Shoe Rack nos

40.10.3 SUNDRIES

H Racking system, FILO Drive in Rack, 3 tier 3 Deep, 1.5m height, plt
including all supports and accessories as drawing specified

To Collection Rp. -

COLLECTIONS

Page 40.10 / 1 -

Page 40.10 / 2 -

TA2459 Lesaffre Garuda 27/60 69ee-c99f-6b5d-bd85-2.10


Item BILL NO. 40
40.10 SPECIALITIES Qty. Unit Rate Rupiahs
No YEAST CREAM PRODUCTION

40.10 SPECIALITIES
CARRIED TO SUMMARY AT END OF BILL NO. 40 Rp. -

TA2459 Lesaffre Garuda 28/60 69ee-c99f-6b5d-bd85-2.10


Item BILL NO. 40
40.11 MECHANICAL WORKS Qty. Unit Rate Rupiahs
No YEAST CREAM PRODUCTION

40.11 MECHANICAL WORKS

40.11.1 DOMESTIC COLD WATER

DOMESTIC COLD WATER SYSTEM INSTALLATION


Supply and install Domestic Water pipes; PPR PN 10 including fittings (for 50
mm dia. Pipe or less) fixed in position complete with seals (for underground
pipe) supports, hangers, brackets, clamp, painting, and other necessary fixing
and jointing material in accordance to the technical specification and drawings,
as described;

PIPEWORKS

A 15mm diameter pipe m

B 20mm diameter pipe m

C 25mm diameter pipe m

D 32mm diameter pipe m

E 40mm diameter pipe m

F 50mm diameter pipe m

VALVE AND ANCILLARIES

G 25mm diameter gate valve no

H 32mm diameter gate valve no

I 40mm diameter gate valve no

J 50mm diameter gate valve no

40.11.2 SEWAGE AND WASTE WATER SYSTEM

SEWAGE AND WASTE WATER SYSTEM INSTALLATION


Supply and Install Waste water, Sewage water pipes and Venting pipes; PVC Class
AW 10 kg/m2 including fittings (for 50 mm dia. Pipe or less) fixed in position
complete with supports, hangers, brackets, clamp, painting, and other necessary
fixing and jointing material in accordance to the technical specification and
drawings, as described;

PIPEWORKS (SEWAGE AND WASTE)

K 50mm diameter pipe m

L 100mm diameter pipe m

M 160mm diameter pipe m

N 200mm diameter pipe m

TA2459 Lesaffre Garuda 29/60 69ee-c99f-6b5d-bd85-2.11


Item BILL NO. 40
40.11 MECHANICAL WORKS Qty. Unit Rate Rupiahs
No YEAST CREAM PRODUCTION

To Collection Rp. -

TA2459 Lesaffre Garuda 30/60 69ee-c99f-6b5d-bd85-2.11


Item BILL NO. 40
40.11 MECHANICAL WORKS Qty. Unit Rate Rupiahs
No YEAST CREAM PRODUCTION

SEWAGE AND WASTE WATER SYSTEM INSTALLATION (Cont'd)


Supply and Install Waste water, Sewage water pipes and Venting pipes; PVC Class
AW 10 kg/m2 including fittings (for 50 mm dia. Pipe or less) fixed in position
complete with supports, hangers, brackets, clamp, painting, and other necessary
fixing and jointing material in accordance to the technical specification and
drawings, as described;

PIPEWORKS (VENTING)

A 40mm diameter pipe m

B 50mm diameter pipe m

FITTINGS

C Fitting 110mm diameter no

D Fitting 160mm diameter no

E Fitting 200mm diameter no

VALVE AND ANCILLARIES

F Ventcap 50mm diameter no

G Clean out 50mm diameter no

H Clean out 100mm diameter no

40.11.3 INDUSTRIAL WASTE WATER SYSTEM

INDUSTRIAL WASTE WATER SYSTEM INSTALLATION


Supply and Install Industrial Waste Water pipes; Stainless steel 316L schedule 10
and FRP pipe including excavation for undergground pipe and fittings (for 50mm
dia. Pipe or less) fixed in position complete with supports, hangers, brackets,
clamp,painting, and other necessary fixing a

PIPEWORKS

I 500mm diameter pipe m

J 450mm diameter pipe; FRP m

K 350mm diameter pipe m

L 250mm diameter pipe m

M 200mm diameter pipe m

N 150mm diameter pipe m

To Collection Rp. -

TA2459 Lesaffre Garuda 31/60 69ee-c99f-6b5d-bd85-2.11


Item BILL NO. 40
40.11 MECHANICAL WORKS Qty. Unit Rate Rupiahs
No YEAST CREAM PRODUCTION

TA2459 Lesaffre Garuda 32/60 69ee-c99f-6b5d-bd85-2.11


Item BILL NO. 40
40.11 MECHANICAL WORKS Qty. Unit Rate Rupiahs
No YEAST CREAM PRODUCTION

40.11.3 INDUSTRIAL WASTE WATER SYSTEM (CONT'D)

INDUSTRIAL WASTE WATER SYSTEM INSTALLATION


Supply and Install Industrial Waste Water pipes; Stainless steel 316L schedule 10
and FRP pipe including excavation for undergground pipe and fittings (for 50mm
dia. Pipe or less) fixed in position complete with supports, hangers, brackets,
clamp,painting, and other necessary fixing a

FITTINGS

A Fitting 500mm diameter no

B Fitting 450mm diameter; FRP no

C Fitting 350mm diameter no

D Fitting 250mm diameter no

E Fitting 200mm diameter no

F Fitting 150mm diameter no

40.11.4 HYDRANT & SPRINKLER SYSTEM

HYDRANT SYSTEM INSTALLATION


Supply and install Hydrant pipes, Black steel pipe to ASTM A 53 schedule 40 ,
Grade B, including fitting (for 50 mm dia. Pipe or less) fixed in position complete
with supports, hangers, brackets, clamp, painting, and other necessary fixing and
jointing material in accordance to the technical specification and drawings, as
described;

PIPEWORKS

G 40mm diameter pipe m

H 65mm diameter pipe m

I 80mm diameter pipe m

J 100mm diameter pipe m

K 150mm diameter pipe m

FITTINGS

L Fitting 65mm diameter no

M Fitting 80mm diameter no

N Fitting 100mm diameter no

O Fitting 150mm diameter no

TA2459 Lesaffre Garuda 33/60 69ee-c99f-6b5d-bd85-2.11


Item BILL NO. 40
40.11 MECHANICAL WORKS Qty. Unit Rate Rupiahs
No YEAST CREAM PRODUCTION

To Collection Rp. -

TA2459 Lesaffre Garuda 34/60 69ee-c99f-6b5d-bd85-2.11


Item BILL NO. 40
40.11 MECHANICAL WORKS Qty. Unit Rate Rupiahs
No YEAST CREAM PRODUCTION

40.11.4 HYDRANT & SPRINKLER SYSTEM (CONT'D)

HYDRANT SYSTEM INSTALLATION


Supply and install Hydrant pipes, Black steel pipe to ASTM A 53 schedule 40 ,
Grade B, including fitting (for 50 mm dia. Pipe or less) fixed in position complete
with supports, hangers, brackets, clamp, painting, and other necessary fixing and
jointing material in accordance to the technical specification and drawings, as
described;

VALVE AND ANCILLARIES

A 80mm diameter gate valve, UL listed & FM approved no

B Portable fire extinguisher with capacity 6 kg chemical powder ABC type. no

C Indoor Hydrant Box (IHB) complete with hose rack, rubber hose, hose reel, valve no
and nozzle

SPRINKLER SYSTEM INSTALLATION


Supply and install Sprinkler pipes, Black steel pipe to ASTM A 53 schedule 40 ,
Grade B, including fitting (for 50 mm dia. Pipe or less) fixed in position complete
with supports, hangers, brackets, clamp, painting, and other necessary fixing and
jointing material in accordance to the technical specification and drawings, as
described;

PIPEWORKS

D 25mm diameter pipe m

E 32mm diameter pipe m

F 40mm diameter pipe m

G 50mm diameter pipe m

H 65mm diameter pipe m

I 80mm diameter pipe m

J 100mm diameter pipe m

K 150mm diameter pipe m

L 200mm diameter pipe m

FITTINGS

M Fitting 65mm diameter no

N Fitting 80mm diameter no

O Fitting 100mm diameter no

P Fitting 150mm diameter no

Q Fitting 200mm diameter no

TA2459 Lesaffre Garuda 35/60 69ee-c99f-6b5d-bd85-2.11


Item BILL NO. 40
40.11 MECHANICAL WORKS Qty. Unit Rate Rupiahs
No YEAST CREAM PRODUCTION

To Collection Rp. -

TA2459 Lesaffre Garuda 36/60 69ee-c99f-6b5d-bd85-2.11


Item BILL NO. 40
40.11 MECHANICAL WORKS Qty. Unit Rate Rupiahs
No YEAST CREAM PRODUCTION

40.11.4 HYDRANT & SPRINKLER SYSTEM (CONT'D)

SPRINKLER SYSTEM INSTALLATION


Supply and install Sprinkler pipes, Black steel pipe to ASTM A 53 schedule 40 ,
Grade B, including fitting (for 50 mm dia. Pipe or less) fixed in position complete
with supports, hangers, brackets, clamp, painting, and other necessary fixing and
jointing material in accordance to the technical specification and drawings, as
described;

VALVE AND ANCILLARIES

A Head sprinkler pendant type no

B Head sprinkler upright type no

C Branch Control Valve (BCV); 65mm diameter set

D Alarm Control Valve (ACV); 200mm diameter set

E Alarm Control Valve (ACV); 65mm diameter set

F AAV; 25mm diameter no

G Test Drain; 25 mm diameter set

H Flexible coupling; 65mm diameter no

I Flexible coupling; 200mm diameter no

To Collection Rp. -

COLLECTION

Page 40.11 /1 -

Page 40.11 /2 -

Page 40.11 /3 -

Page 40.11 /4 -

Page 40.11 /5 -

40.11 MECHANICAL WORKS


CARRIED TO SUMMARY AT END OF BILL NO. 40 Rp. -

TA2459 Lesaffre Garuda 37/60 69ee-c99f-6b5d-bd85-2.11


Item BILL NO. 40
40.11 MECHANICAL WORKS Qty. Unit Rate Rupiahs
No YEAST CREAM PRODUCTION

TA2459 Lesaffre Garuda 38/60 69ee-c99f-6b5d-bd85-2.11


Item BILL NO. 40
40.2 ELECTRICAL WORKS Qty. Unit Rate Rupiahs
No YEAST CREAM PRODUCTION

40.12 ELECTRICAL WORKS

40.12.1 SUB DISTRIBUTION BOARDS


Supply, Install and Testing Commissioning the following Sub Distribution board
fix in position includes circuit breaker, board, busbar, digital multimeter,
contactor, surge arrester, potensial transformer, current transformer, indicator
lamp, fuse, loto, star / stop push button, and all necessary accessories in
arcondance to the technical spesification as shown on drawing, as described : -

A 40DB01 no

B 40DB02 no

C 40DBAC01 no

40.12.2 MAIN AND SUB-MAINS CABLES


Supply and Install the following Main and Sub-Mains circuit distribution cable
run & fixed on cable tray/ladders including all necessary accessories in
arcondance to the technical spesification as shown on drawing, as described : -

D From SDB…. to 40DB01 m by other package

E From SDB…. to 40DB02 m by other package

40.12.3 LIGHTING FIXTURES & POWER OUTLET


Supply and Install the following light fittings including tubes or lamps fixed in
position complete with all accessories and support in accordance with the
technical specification and drawings, as described :-

F High bay LED 75W, 10503 lm no

G High bay LED 75W, 10503 lm, c/w nicad battery duration 1 hour no

H High bay LED 90W, 11000 lm no

I Recessed mounted TLED 40W, 220V, 3709 lm no

J Recessed mounted TLED 40W, 220V, 3709 lm, c/w nicad battery duration 1 no
hour
K Exit sign LED 5W, 220V, wall mounted no

L Waterproof LED 20W, 220V, IP65, 2000 lm, L600 no

M Waterproof LED 20W, 220V, IP65, 2000 lm, L600, c/w nicad battery duration 1 no
hour

N Waterproof LED 40W, 220V, IP65, 400 lm, L1200 no

O Waterproof LED 40W, 220V, IP65, 400 lm, L1200, c/w nicad battery duration 1 no
hour

P Waterproof LED 20W, 220V, IP65, mounted on steel pipe 2.5mtr height no
Ø50mm

Q Flood light LED 100W, 9500 lm no

To Collection Rp. -

TA2459 Lesaffre Garuda 39/60 69ee-c99f-6b5d-bd85-2.12


Item BILL NO. 40
40.2 ELECTRICAL WORKS Qty. Unit Rate Rupiahs
No YEAST CREAM PRODUCTION

TA2459 Lesaffre Garuda 40/60 69ee-c99f-6b5d-bd85-2.12


Item BILL NO. 40
40.2 ELECTRICAL WORKS Qty. Unit Rate Rupiahs
No YEAST CREAM PRODUCTION

40.12.3 LIGHTING FIXTURES & POWER OUTLET (Cont'd)


Supply and Install the following light fittings including tubes or lamps fixed in
position complete with all accessories and support in accordance with the
technical specification and drawings, as described :-

A Emergency lighting, double head LED 2x4W, 220V no

B Downlight 16W 220V, minimum 1200 lm no

C Downlight 16W 220V, minimum 1200 lm, c/w nicad battery duration 1 hour no

D Batten LED 40W, 220V, 4100 lm no

E Batten LED 40W, 220V, 4100 lm, c/w nicad battery duration 1 hour no

Supply and Install the following switches including provision of steel/metal box
and all accessories accordance with the technical specification and drawings, as
described :-

F Single gang, 1 way switch, 10A no

G Double gang, 1 way switch, 10A no

Supply and Install lighting & switch cables from sub circuit to final circuit
including grounding system and all neccessary accessories accordance with the
technical specification and drawings, as described :-

H Cabling point from local panel (500V/CU/PVC 3C x 2.5 mm² shall be UV & no
chemical resistance) run-in and with PVC high impact conduit) to; lighting and
switch

POWER OUTLET
Supply and Install the following power outlet including provision of steel/metal
box and all accessories accordance with the Technical Specification and
drawings, as described :-

I General socket outlet, wall mounted, 16A, 250V, single gang no

J General socket outlet, wall mounted, 16A, 250V, double gang no

K General socket outlet fly catcher, wall mounted, 16A, 250V, single gang no

L General socket outlet c/w cover, wall mounted, 16A, 250V, (waterproof) single no
gang

M General socket outlet hand dryer, wall mounted, 16A, 250V, (waterproof) single no
gang

N Industrial socket outlet, mounted on the front panel door, 16A, 250V, IP65, 1 Ph no

O Industrial socket outlet, mounted on the front panel door, 32A, 400V, IP65, 3 Ph no

To Collection Rp. -

TA2459 Lesaffre Garuda 41/60 69ee-c99f-6b5d-bd85-2.12


Item BILL NO. 40
40.2 ELECTRICAL WORKS Qty. Unit Rate Rupiahs
No YEAST CREAM PRODUCTION

TA2459 Lesaffre Garuda 42/60 69ee-c99f-6b5d-bd85-2.12


Item BILL NO. 40
40.2 ELECTRICAL WORKS Qty. Unit Rate Rupiahs
No YEAST CREAM PRODUCTION

40.12.4 TRAYS AND LADDERS


Supply and Install hot dip galvanized tray and ladder 2mm thickness include
jointing, elbow, tee, fixing accessories and hangers and all necessary accessories
accordance with the technical specification and drawings, as described :-

Electrical

A Cable tray 300x100mm m

B Wiremesh tray 300x100mm m

C Wiremesh tray 200x100mm m

Electronic

D Cable tray 200x100mm m

E Wiremesh tray 200x100mm m

40.12.5 GROUNDING & LIGHTNING PROTECTION SYSTEM


Supply and Install Grounding system for panel and equipment complete with
support and all neccessary accessories accordance with the technical
specification and drawings, as described :-

F Earth pit, Conductor clamp and rod electrode, dia 19mm x 3000 length no

G Earthing bonding bar (copper bar) 40x3mm thk, c/w isolator no

H BC 70mm2, grounding cable for main/mesh earthing c/w connector and m


grounding lug

I Potential earth clamp (100kA) no

J Bonding cable NYAF 16mm2 m

K Bonding cable NYAF 25mm2 m

L Bonding cable NYAF 35mm2 m

M Bonding cable NYAF 50mm2 m

40.12.6 FIRE ALARM


Supply and Install the following Fire Alarm Equipment complete with support, and
all necessary accessories in accordance to the technical specification and
drawings, as described : -

N JBFA-40-01 no

O Addressable photoelectric smoke detector no

P UV/IR Beam detector type receive/transmit no

Q Addressable manual call point no

To Collection Rp. -

TA2459 Lesaffre Garuda 43/60 69ee-c99f-6b5d-bd85-2.12


Item BILL NO. 40
40.2 ELECTRICAL WORKS Qty. Unit Rate Rupiahs
No YEAST CREAM PRODUCTION

TA2459 Lesaffre Garuda 44/60 69ee-c99f-6b5d-bd85-2.12


Item BILL NO. 40
40.2 ELECTRICAL WORKS Qty. Unit Rate Rupiahs
No YEAST CREAM PRODUCTION

40.12.6 FIRE ALARM (Cont'd)


Supply and Install the following Fire Alarm Equipment complete with support, and
all necessary accessories in accordance to the technical specification and
drawings, as described : -

A Horn & strobe light no

B Flow switch sprnkler system no

C Tamper switch sprnkler system no

D End of line (EOL) no

Supply and Install the following Fire Alarm cables in final sub-circuit to
termination, run-in and with steel conduit 20mm dia; including earthing system
and all necessary accessories in accordance to the technical spesification as
shown on drawing, as described : -

E Power Cable FRC 2Cx2,5 mm2; from control room BD50 m

F Cable FRC STP 2Cx1,5 mm2; for detector point no

G Cable FRC STP 2Cx1,5 mm2; for manual call point no

H Cable FRC 2Cx1,5 mm2; for horn & strobe light point no

40.12.7 PUBLIC ADDRESS


Supply and Install the following Sound System Equipment complete with support,
and all necessary accessories in accordance to the technical specification and
drawings, as described : -

I Wall mounted switch rack JBPA-40-01 (SR-40-01) no

J Indoor ceiling mounted speaker 6W no

K Horn speaker 15W no

L Column speaker 10W no

Supply and Install the following Public Address cables in final sub-circuit to
termination, run-in and with steel conduit 20mm dia; including earthing system
and all necessary accessories in accordance to the technical spesification as
shown on drawing, as described : -

M Cable FO OM3; from BD96 m

N Cable NYMHY 2Cx1,5 mm2; for column speaker point no

O Cable NYMHY 2Cx1,5 mm2; for indor ceiling speaker point no

P Cable NYMHY 2Cx1,5 mm2; for horn speaker point no

Q Cable NYMHY 2Cx1,5 mm2; for column speaker point no

To Collection Rp. -

TA2459 Lesaffre Garuda 45/60 69ee-c99f-6b5d-bd85-2.12


Item BILL NO. 40
40.2 ELECTRICAL WORKS Qty. Unit Rate Rupiahs
No YEAST CREAM PRODUCTION

TA2459 Lesaffre Garuda 46/60 69ee-c99f-6b5d-bd85-2.12


Item BILL NO. 40
40.2 ELECTRICAL WORKS Qty. Unit Rate Rupiahs
No YEAST CREAM PRODUCTION

40.12.8 DATA AND TELEPHONE


Supply and Install the following Data and Communication System
Equipment complete with support, and all necessary accessories in
accordance to the technical specification and drawings, as described : -

A Wall mounted switch rack SR-40-01 no

B Single gang type data outlet (RJ45) no

C Single gang type telephone outlet (RJ45)

Supply and Install the following Data and Telephone cables in final sub-circuit
to termination, run-in and with steel conduit 20mm dia; including earthing system
and all necessary accessories in accordance to the technical spesification as
shown on drawing, as described : -

D Cable UTP-CAT6/FO mm2; for data outlet point no

E Cable UTP-CAT6/FO mm2; for telephone outlet point no

F Cable FO OM3; from BD96 m

40.12.9 SECURITY SYSTEM


Supply and Install the following Security System Equipment complete with
support, and all necessary accessories in accordance to the technical specification
and drawings, as described : -

G Wall mounted switch rack SR-40-01 no

H IP based bullet fix camera indoor type no

I IP based bullet fix camera outdoor type no

J IP based dome camera no

K Acces control door consist of; no


Door control
Finger print / card reader
Push button door release

Supply and Install the following Security cables in final sub-circuit to


termination, run-in and with PVC conduit 25mm dia underground direct burried
min 400mm below grade or through pipe rack; including earthing system and all
necessary accessories in accordance to the technical spesification as shown on
drawing, as described : -

L Cable UTP-CAT6/FO; for bullet fix camera indoor type point no

M Cable UTP-CAT6/FO; for bullet fix camera outdoor type point no

N Cable UTP-CAT6/FO; for dome camera point no

O Cable UTP-CAT6/FO; for acces control door point no

P Cable FO OM3; from BD96 m

To Collection Rp. -

TA2459 Lesaffre Garuda 47/60 69ee-c99f-6b5d-bd85-2.12


Item BILL NO. 40
40.2 ELECTRICAL WORKS Qty. Unit Rate Rupiahs
No YEAST CREAM PRODUCTION

TA2459 Lesaffre Garuda 48/60 69ee-c99f-6b5d-bd85-2.12


Item BILL NO. 40
40.2 ELECTRICAL WORKS Qty. Unit Rate Rupiahs
No YEAST CREAM PRODUCTION

COLLECTIONS

Page 40.12 /1 -

Page 40.12 /2 -

Page 40.12 /3 -

Page 40.12 /4 -

Page 40.12 /5 -

40.2 ELECTRICAL WORKS


CARRIED TO SUMMARY AT END OF BILL NO. 40 Rp. -

TA2459 Lesaffre Garuda 49/60 69ee-c99f-6b5d-bd85-2.12


Item BILL NO. 40
40.2 ELECTRICAL WORKS Qty. Unit Rate Rupiahs
No YEAST CREAM PRODUCTION

TA2459 Lesaffre Garuda 50/60 69ee-c99f-6b5d-bd85-2.12


Item BILL NO. 40
40.3 HVAC WORKS Qty. Unit Rate Rupiahs
No YEAST CREAM PRODUCTION

40.13 HVAC WORKS

40.13.1 EQUIPMENT

AHU UNIT
Supply and Install of AHU Units complete with hangers/supports,
vibration mountings, neoprene pads and all necessary accessories in
accordance to the technical specification and drawings, as described : -

A AHU-40.00.01, modular hygienic class, chilled water coil type, total no


cooling capacity 341 kWth, supply air flow 33.224 m3/hr, pressure drop
100 pa,

VRF UNIT
Supply and Install of VRF Units complete with hangers/supports, vibration
mountings, neoprene pads and all necessary accessories in accordance to
the technical specification and drawings, as described : -

B IU-VRF.40.00.01; high static split duct, cooling capacity 14kWth, supply no


air flow 760 CMH, static pressure 220 pa, 0.37kW, 220V/1Ph/50Hz

C IU-VRF.40.00.02; high static split duct, cooling capacity 28kWth, supply no


air flow 1357 CMH, static pressure 220 pa, 1.1kW, 380V/3Ph/50Hz

D IU-VRF.40.02.01; 4 way cassete, cooling capacity 3.75kWth, supply air no


flow 660 CMH, free blow, 0.1kW, 220V/1Ph/50Hz

E IU-VRF.40.02.02; 1 way cassete, cooling capacity 3.4kWth, supply air no


flow 666 CMH, free blow, 0.1kW, 220V/1Ph/50Hz

F IU-VRF.40.02.03; 2 way cassete, cooling capacity 3.1kWth, supply air no


flow 666 CMH, free blow, 0.1kW, 220V/1Ph/50Hz

G IU-VRF.40.02.04A&B; 4 way cassete, cooling capacity 6.95kWth, supply no


air flow 1020 CMH, free blow, 0.1kW, 220V/1Ph/50Hz

H IU-VRF.40.02.05; high static split duct, cooling capacity 14kWth, supply no


air flow 851 CMH, static pressure 220 pa, 0.37kW, 220V/1Ph/50Hz

I OU-VRF.40.00.01; air cooled VRF, cooling capacity 43-56kWth, supply no


air flow 9600 CMH/Module, 380V/3Ph/50Hz

J OU-VRF.40.02.01; air cooled VRF, cooling capacity 48.5-61kWth, supply no


air flow 9600 CMH/Module, 380V/3Ph/50Hz

DX UNIT
Supply and Install of DX Units complete with hangers/supports, vibration
mountings, neoprene pads and all necessary accessories in accordance to
the technical specification and drawings, as described : -

K IU-DX.40.00.01A-B; ceiling suspend, cooling capacity 7.3kWth, supply no


air flow 1520 CMH, 0.1kW, 220V/1Ph/50Hz

L IU-DX.40.00.02A-B; ceiling suspend, cooling capacity 6.9kWth, supply no


air flow 1520 CMH, 0.1kW, 220V/1Ph/50Hz

To Collection Rp. -

TA2459 Lesaffre Garuda 51/60 69ee-c99f-6b5d-bd85-2.13


Item BILL NO. 40
40.3 HVAC WORKS Qty. Unit Rate Rupiahs
No YEAST CREAM PRODUCTION

TA2459 Lesaffre Garuda 52/60 69ee-c99f-6b5d-bd85-2.13


Item BILL NO. 40
40.3 HVAC WORKS Qty. Unit Rate Rupiahs
No YEAST CREAM PRODUCTION

40.13.1 EQUIPMENT (Cont'd)

DX UNIT
Supply and Install of DX Units complete with hangers/supports, vibration
mountings, neoprene pads and all necessary accessories in accordance to
the technical specification and drawings, as described : -

A IU-DX.40.00.03; ceiling suspend, cooling capacity 2.7kWth, supply no


air flow 552 CMH, 0.1kW, 220V/1Ph/50Hz

B IU-DX.40.02.01A-B; ceiling suspend, cooling capacity 13.3kWth, supply no


air flow 1520 CMH, 0.1kW, 220V/1Ph/50Hz

FAN
Supply and Install of Fan Units complete with hangers/supports, vibration
mountings, neoprene pads and all necessary accessories in accordance to the
technical specification and drawings, as described : -

C Exhasut Fan EF-40.00.01, mixflow Inline type, cap 996 CMH, static pressure no
167 pa, 0.37kW, 220V/1Ph/50Hz

D Exhasut Fan EF-40.00.02, mixflow Inline type, cap 1041 CMH, static pressure no
363 pa, 0.37kW, 220V/1Ph/50Hz

E Exhasut Fan EF-40.02.01, mixflow Inline type, cap 549 CMH, static pressure no
201 pa, 0.1kW, 220V/1Ph/50Hz

F Exhasut Fan EF-40.02.02, mixflow Inline type, cap 127 CMH, static pressure no
191 pa, 0.1kW, 220V/1Ph/50Hz

40.13.2 DUCTWORK
Supply and Install galvanized steel sheet ductworks complete with
hangers, supports, brackets and all necessary fixing accessories in
accordance to the technical tpecification and drawings, as described :-

SUPPLY AIR DUCT


With external insulation (closed cell elastomeric fire retardant type class 0,
FM Approved, 50mm thickness + AL sheet Jacketing 0.4mm thckness)

G Supply air duct (SAD) ; 250x200mm m

H Supply air duct (SAD) ; 200x200mm m

Install Textile Fabric duct including with support/rail and similar to it, fittings &
another accessories which are comply to clean room installation
requirement standard in accordance to the technical tpecification and
drawings, as described :-

I Supply air duct (SAD) ; 1200mm diameter m

To Collection Rp. -

TA2459 Lesaffre Garuda 53/60 69ee-c99f-6b5d-bd85-2.13


Item BILL NO. 40
40.3 HVAC WORKS Qty. Unit Rate Rupiahs
No YEAST CREAM PRODUCTION

TA2459 Lesaffre Garuda 54/60 69ee-c99f-6b5d-bd85-2.13


Item BILL NO. 40
40.3 HVAC WORKS Qty. Unit Rate Rupiahs
No YEAST CREAM PRODUCTION

40.13.2 DUCTWORK (Cont'd)


Supply and Install galvanized steel sheet ductworks complete with
hangers, supports, brackets and all necessary fixing accessories in
accordance to the technical tpecification and drawings, as described :-

FRESH AIR DUCT


With external insulation (closed cell elastomeric fire retardant type class 0,
FM Approved, 32mm thickness + AL sheet Jacketing 0.4mm thckness)

A Fresh air duct (FAD) ; 400x250mm m

B Fresh air duct (FAD) ; 250x250mm

RETURN AIR DUCT


With external insulation (closed cell elastomeric fire retardant type class 0,
FM Approved, 32mm thickness + AL sheet Jacketing 0.4mm thckness)

C Return air duct (RAD) ; 1200mm diameter m

Install Textile Fabric duct including with support/rail and similar to it, fittings &
another accessories which are comply to clean room installation
requirement standard in accordance to the technical tpecification and
drawings, as described :-

D Return air duct (RAD) ; 1600x800mm m

EXHAUST AIR DUCT


With external insulation (closed cell elastomeric fire retardant type class 0,
FM Approved, 25mm thickness + AL sheet Jacketing 0.4mm thckness)

E Exhaust air duct (EAD) ; 300x300mm m

F Exhaust air duct (EAD) ; 300x250mm m

G Exhaust air duct (EAD) ; 250x200mm m

H Exhaust air duct (EAD) ; 200x200mm m

I Exhaust air duct (EAD) ; 150x150mm m

40.13.3 GRILLE AND DIFFUSER

Supply and Install Diffuser, Grilles and Volume Damper complete with air
equalising deflector blades, plenum box (if any) and all necessary
accessories including fixing, frame and connecting to ductwork in
accordance with the technical specification and drawings, as described :-

J Supply air diffuser (SAD) ; 400x400mm no

K Supply air grille (SAG) ; 325x225mm no

L Intake air louvre (IAL) ; 400x330mm no

M Fresh air louvre (EAG) ; 660x330mm no

TA2459 Lesaffre Garuda 55/60 69ee-c99f-6b5d-bd85-2.13


Item BILL NO. 40
40.3 HVAC WORKS Qty. Unit Rate Rupiahs
No YEAST CREAM PRODUCTION

To Collection Rp. -

TA2459 Lesaffre Garuda 56/60 69ee-c99f-6b5d-bd85-2.13


Item BILL NO. 40
40.3 HVAC WORKS Qty. Unit Rate Rupiahs
No YEAST CREAM PRODUCTION

40.13.3 GRILLE AND DIFFUSER (Cont'd)

Supply and Install Diffuser, Grilles and Volume Damper complete with air
equalising deflector blades, plenum box (if any) and all necessary
accessories including fixing, frame and connecting to ductwork in
accordance with the technical specification and drawings, as described :-

A Exhaust air grille (EAG) ; 150x150mm

B Exhaust air grille (EAG) ; 200x200mm

C Exhaust air grille (EAG) ; 325x225mm

D Exhaust air louvre (EAL) ; 400x330mm

E Exhaust air louvre (EAL) ; 660x400mm

F Volume control damper (VCD) ; 150x150mm

G Volume control damper (VCD) ; 200x150mm

H Volume control damper (VCD) ; 200x200mm

40.13.4 REFRIGERANT & DRAIN PIPES


Supply and install the following Refrigerant Copper Pipeworks including
FM Approved insulation ,vapour barrier, trap, fittings (for 50mm diameter
pipe or less), joints, flanges, support and all accessories in accordance to
the technical specification and drawings, as described : -

I 6.5 mm diameter pipe copper c/w insulation m

J 9,5 mm diameter pipe copper c/w insulation m

K 12,7 mm diameter pipe copper c/w insulation m

L 15,8 mm diameter pipe copper c/w insulation m

M 22,2 mm diameter pipe copper c/w insulation m

N 28,5 mm diameter pipe copper c/w insulation m

DRAIN PIPES
O 25 mm diameter pipe PVC Class AW c/w insulation m

P 32 mm diameter pipe PVC Class AW c/w insulation m

TA2459 Lesaffre Garuda 57/60 69ee-c99f-6b5d-bd85-2.13


Item BILL NO. 40
40.3 HVAC WORKS Qty. Unit Rate Rupiahs
No YEAST CREAM PRODUCTION

To Collection Rp. -

TA2459 Lesaffre Garuda 58/60 69ee-c99f-6b5d-bd85-2.13


Item BILL NO. 40
40.3 HVAC WORKS Qty. Unit Rate Rupiahs
No YEAST CREAM PRODUCTION

COLLECTIONS

Page 40.13 /1 -

Page 40.13 /2 -

Page 40.13 /3 -

Page 40.13 /4 -

Page 40.13 /5 -

40.3 HVAC WORKS


CARRIED TO SUMMARY AT END OF BILL NO. 40 Rp. -

TA2459 Lesaffre Garuda 59/60 69ee-c99f-6b5d-bd85-2.13


Item BILL NO. 40
40.3 HVAC WORKS Qty. Unit Rate Rupiahs
No YEAST CREAM PRODUCTION

TA2459 Lesaffre Garuda 60/60 69ee-c99f-6b5d-bd85-2.13


BILL NO. 50
INSTANT DRY YEAST

TA2459 Lesaffre Garuda 1/75 23de-38a4-c013-c37e-Cover


Item BILL NO. 50 SUMMARY RUPIAHS
No. INSTANT DRY YEAST

SUMMARY

50.1 DEMOLITION N/A

50.2 EARTHWORK -

50.3 CONCRETE -

50.4 MASONRY -

50.5 METALS -

50.7 THERMAL AND MOISTURE PROTECTION -

50.8 DOORS AND WINDOWS -

50.9. FINISHES -

50.10 SPECIALITIES -

50.11 MECHANICAL WORKS -

50.12 ELECTRICAL WORKS -

50.13 HVAC WORKS -

BILL NO. 50
CARRIED TO SUMMARY -

TA2459 Lesaffre Garuda 2/75 23de-38a4-c013-c37e-Sum


Item BILL NO. 50 Qty Unit Rate Rupiahs
50.2 EARTHWORK
No. INSTANT DRY YEAST

50.2.1 CUT OFF PILE HEAD

Cut off pile head as drawings

A Spun pile, dia. 400mm nos

50.2.2 EARTHWORK

Excavation, disposal and backfill in any material including rock or hard


material, working space at parimeter items as defined; Excavating, starting
from stripped level, trenches to receive depth as pecified (insite area)

B To Pile Cap m3

C To Slab m3

D To Tie Beam m3

E To Pedestal m3

F To Drop Panel m3

G To Gutter m3

H To Stair m3

50.2.3 BASE COURSES

Compacted of subgrade to 95% Standard Proctor Density as specified

I To Pile Cap m2

J To Slab m2

K To Tie Beam m2

L To Drop Panel m2

M To Gutter m2

N To Stair m2

Sandfill 100mm thick as specified

O To Pile Cap m2

P To Slab m2

Q To Tie Beam m2

R To Drop Panel m2

S To Gutter m2

T To Stair m2

TA2459 Lesaffre Garuda 3/75 23de-38a4-c013-c37e-2.2


Item BILL NO. 50 Qty Unit Rate Rupiahs
50.2 EARTHWORK
No. INSTANT DRY YEAST

To Collection Rp. -

50.2.4 TERMITE CONTROL

Termite control to soil; The protection against termites by spraying an


insecticide on the soil or on the fill before placing the vapor and after
building completed and importing landfill; undertaken by an approved
specialist; (5 years quarantee to be given) as specified.

A To Pile Cap m2

B To Slab m2

C To Tie Beam m2

D To Pedestal m2

E To Drop Panel m2

F To Gutter m2

G To Stair m2

50.2.5 OTHERS

Plastic sheet

H To Pile Cap m2

I To Slab incl. ramp m2

J To Tie Beam m2

K To Drop Panel m2

L To Gutter m2

M To Stair m2

To Collection Rp. -

COLLECTIONS

Page 50.2/1 -

Page 50.2/2 -

TA2459 Lesaffre Garuda 4/75 23de-38a4-c013-c37e-2.2


Item BILL NO. 50 Qty Unit Rate Rupiahs
50.2 EARTHWORK
No. INSTANT DRY YEAST

50.2 EARTHWORK
CARRIED TO SUMMARY AT END OF BILL NO. 50 Rp. -

TA2459 Lesaffre Garuda 5/75 23de-38a4-c013-c37e-2.2


Item BILL NO. 50
50.3 CONCRETE Qty. Unit Rate Rupiahs
No. INSTANT DRY YEAST

50.3.1 FORMWORK

50.3.1.1 IN GROUND FORMWORK

The design, certification, construction and performance of the formwork,


falsework and backpropping shall be the responsibilty of Contractor.
Proposed method of installation and removal of formwork is to be
submitted to the Superintendent for comment prior to work being carried
out as per dwg note.
In ground formwork as follows; permanent formwork system for in-place
concrete, concrete hollow block 100mm thick, finish starting at/from any
level and including rebates or grooves formers as described to

A To Pile Cap m2 -

B To Slab m2 -

C To Tie Beam m2 -

E To Drop Panel m2 -

D To Gutter m2 -

G To Stair m2 -

50.3.1.2 UPPER STRUCTURE FORMWORK

Smooth-Formed Finished concrete, plywood, metal, or other approved


panel materials, finish starting at/from any level and rebates or groove
formers as specified

H To Slab m2 -

I To Beam m2 -

J To Pedestal and Column m2 -

K To Wall/Parapet/Concrete Curb m2 -

L To Gutter m2 -

M To Stair m2 -

N To Plinths m2 -

Bondex BMT 0.7 thick including shear connector, support and all
necessary as drawing specified

O To Floor m2 -

50.3.2 CONCRETE

In-Situ Concrete

In-situ concrete designed mix Grade 30 Mpa, (K-350) NFA; ± 20mm


aggregate, vibrated with standard flatness as described ;

O To Pile Cap m3 -

TA2459 Lesaffre Garuda 6/75 23de-38a4-c013-c37e-2.3


Item BILL NO. 50
50.3 CONCRETE Qty. Unit Rate Rupiahs
No. INSTANT DRY YEAST

To Collection Rp. -

50.3.2 CONCRETE, CONT'D

In-Situ Concrete

In-situ concrete designed mix Grade 30 Mpa, (K-350) NFA; ± 20mm


aggregate, vibrated with standard flatness as described ;

A To Slab and Upper Slab m3 -

B To Tie Beam and Upper Beam m3 -

C To Pedestal and Column m3 -

D To Wall/Parapet/Concrete Curb m3 -

E To Gutter m3 -

F To Stair m3 -

G To Plinths m3 -

Lean Concrete

Plain in-situ concrete, designed mix grade f'c= Mpa,(K-125), 40mm


aggregate, 50mm thick as described,

H To Pile Cap m2 -

I To Slab m2 -

J To Tie Beam m2 -

K To Drop Panel m2 -

L To Gutter m2 -

50.3.3 REINFORCEMENT

Manufacture reinforcement bars is according to "Manual of Standard


Practice" CRSI's as follows; supply, cleaned, measurement, positioning,
setting and install. Reinforcement measure include joint dowel bars,
bolsters, chairs, spacers and other device for spacing, supporting and
fastening reinforcing bars and welded wire reinforcement in place.

Wiremesh M10-150 as specified

To Slab 2 layers m2 -

Reinforcing bars is Grade 60/420 deformed or Grade BJTD 40 deformed.


round mild steel, as described in

M Dia. mm, To Pile Cap kg -

N Dia. mm, To Pile Cap kg -

O Dia. 19mm, To Slab and Upper Slab kg -

TA2459 Lesaffre Garuda 7/75 23de-38a4-c013-c37e-2.3


Item BILL NO. 50
50.3 CONCRETE Qty. Unit Rate Rupiahs
No. INSTANT DRY YEAST

P Dia. 16mm, To Slab and Upper Slab kg -

To Collection Rp. -

50.3.3 REINFORCEMENT, CONT'D

Reinforcing bars is Grade 60/420 deformed or Grade BJTD 40 deformed.


round mild steel, as described in

A Dia. 13mm, To Slab and Upper Slab kg -

B Dia. 10mm To Slab and Upper Slab kg -

C Dia. 29mm, To Tie Beam and Upper Beam kg -

D Dia. 25mm, To Tie Beam and Upper Beam kg -

E Dia. 22mm, To Tie Beam and Upper Beam kg -

F Dia. 19mm, To Tie Beam and Upper Beam kg -

G Dia. 16mm, To Tie Beam and Upper Beam kg -

H Dia. 13mm, To Tie Beam and Upper Beam kg -

I Dia. 10mm, To Tie Beam and Upper Beam kg -

J Dia. 29mm, To Pedestal and Column kg -

K Dia. 25mm, To Pedestal and Column kg -

L Dia. 22mm, To Pedestal and Column kg -

M Dia. 19mm, To Pedestal and Column kg -

N Dia. 16mm, To Pedestal and Column kg -

O Dia. 13mm, To Pedestal and Column kg -

P Dia. 10mm, To Pedestal and Column kg -

Q Dia. 13mm, To Wall/Parapet kg -

R Dia. 16mm, To Drop Panel kg -

S Dia. 16mm, To Plinths kg -

T Dia. 10mm, To Gutter kg -

U Dia. 13mm, To Stair kg -

V Dia. 10mm, To Stair kg -

50.3.4 SUNDRIES

W flexible joint filler, folytirene 5mm m

TA2459 Lesaffre Garuda 8/75 23de-38a4-c013-c37e-2.3


Item BILL NO. 50
50.3 CONCRETE Qty. Unit Rate Rupiahs
No. INSTANT DRY YEAST

To Collection Rp. -

COLLECTIONS

Page 50.3 /1 -

Page 50.3 /2 -

Page 50.3 /2 -

TA2459 Lesaffre Garuda 9/75 23de-38a4-c013-c37e-2.3


Item BILL NO. 50
50.3 CONCRETE Qty. Unit Rate Rupiahs
No. INSTANT DRY YEAST

50.3 CONCRETE
CARRIED TO SUMMARY AT END OF BILL NO. 50 Rp. -

TA2459 Lesaffre Garuda 10/75 23de-38a4-c013-c37e-2.3


Item BILL NO. 50
50.4 MASONRY Qty. Unit Rate Rupiahs
No INSTANT DRY YEAST

50.4.1 UNIT MASONRY

Supply and Install Autoclaved aerated concrete block wall with mortar;
including reinforced concrete bonding ties, anchorage, latching, stiffener
columns and lintels beams as required, all in accordancce with drawings
and specifications
A To Wall 150mm thick External Wall m2 -

B To Wall 150mm thick Internal Wall m2 -

50.4.2 PLASTERED

Plaster; Mortar instant trowelled smooth with and including cement coating
instant as described

C To Wall 150mm thick m2 -

50.4.3 WALL PARTITION

Supply and install sandwich panel PIR Insulation including frames, support
and all necessary in accordance with manufacturer's recommendations, as
specified
D To Roof m2 -

E To Fascia m2 -

F To Wall m2 -

Supply and install gypsum board including frames, support and all
necessary in accordance with manufacturer's recommendations, as specified

G To Wall m2 -

50.4.3 CEILING PARTITION

Supply and install sandwich panel PIR Insulation including frames, support
and all necessary in accordance with manufacturer's recommendations, as
specified
H To Ceiling m2 -

Supply and install calsium silicate board 6mm glued in gypsum ceiling
including ceiling suspension system and fixing accessories all in accordance
with drawings and specifications

I To Ceiling m2 -

Supply and Install Grid system with accoustic tile complete with metal stud
framing hanger and all necessary accessories and support; all in
accordancce with drawings and specifications

J To Ceiling m2 -

50.4 MASONRY

TA2459 Lesaffre Garuda 11/75 23de-38a4-c013-c37e-2.4


Item BILL NO. 50
50.4 MASONRY Qty. Unit Rate Rupiahs
No INSTANT DRY YEAST
CARRIED TO SUMMARY AT END OF BILL NO. 50 Rp. -

TA2459 Lesaffre Garuda 12/75 23de-38a4-c013-c37e-2.4


Item BILL NO. 50 50.5 METALS
Qty. Unit Rate Rupiahs
No INSTANT DRY YEAST

50.5.1 STRUCTURAL FRAMING

The following in steel structure in framing sanblasting and painting


finished ; from ground level to roof floor level; comprising wide flange
bolted to mild steel, cleats, welded to rafter; including all labour,
materials and plant in fabricating,erecting with welded and bolted shop
and site connections; assembling and erecting with welded and bolted
shop and site connections; and all necessaries as specified on
specification and drawing; steel grade as note on specifications ( ASTM
A-36 / BJ 37 for steel structure)
A SC4, WF200x200x8x12 kg -

B SC6, WF250x250x9x14 kg -

C SC7, WF300x150x6.5x9 kg -

D SC10, WF350x350x12x19 kg -

E SC11, WF400x200x8x13 kg -

F SC12, WF400x400x13x21 kg -

G PR7, Z 254x21mm kg -

H R3, WF250x125x6x9-R kg -

I R4, WF300x150x6.5x9-R kg -

J R6, WF400x200x8x13-R kg -

K R8, WF500x200x10x16-R kg -

L R9, WF600x200x11x17-R kg -

M SB12, UNP150x75-SB kg -

N SB13, UNP200x80-SB kg -

O SB16A, L75x75x6 kg -

P SB1A, WF150x150x7x10-SB kg -

Q SB2, WF200x100x5.5x8-SB kg -

R SB3, WF250x125x6x9-SB kg -

S SB4, WF300x150x6.5x9-SB kg -

T SB6, WF400x200x8x13-SB kg -

U SB7, WF450x200x9x14-SB kg -

V SB8, WF500x200x10x16-SB kg -

W SB9, WF600x200x11x17-SB kg -

X SB12/13 kg -

Y SG2, WF200x100x5.5x8-SG kg -

TA2459 Lesaffre Garuda 13/75 23de-38a4-c013-c37e-2.5


Item BILL NO. 50 50.5 METALS
Qty. Unit Rate Rupiahs
No INSTANT DRY YEAST

To Collection Rp. -

50.5.1 STRUCTURAL FRAMING, CONT'D

The following in steel structure in framing sanblasting and painting


finished ; from ground level to roof floor level; comprising wide flange
bolted to mild steel, cleats, welded to rafter; including all labour,
materials and plant in fabricating,erecting with welded and bolted shop
and site connections; assembling and erecting with welded and bolted
shop and site connections; and all necessaries as specified on
specification and drawing; steel grade as note on specifications ( ASTM
A-36 / BJ 37 for steel structure)
A SG3, WF250x125x6x9-SG kg -

B SG4, WF300x150x6.5x9-SG kg -

C SG5, WF350x175x7x11-SG kg -

D SG6, WF400x200x8x13-SG kg -

E SG7, WF450x200x9x14-SG kg -

F SG8, WF500x200x10x16-SG kg -

G SG8A, WF588x300x12x20 -SG kg -

H SG9, WF600x200x11x17-SG kg -

I SG9A, WF700x300x13x24-SG kg -

J TR3, Dia16-TR kg -

K VB15, T150x150x6.5x9 kg -

L VB16, T175x175x7x11 kg -

M VB17, T200x200x8x13 kg -

N WB6, Dia25-WB kg -

O All connecting plates, brackets, cleats, bolts, anchor bolts and stiffeners, Ls -
welding, including sandblasting and painted finish and all necessary
fixing accessories as described

50.5.2 OTHERS

P Supply and install galvanized steel grating 30mm thick including all m2 -
support and accessories per drawings and specifications

Q Supply and install galvanized steel grating 32mm thick including all m2 -
support and accessories per drawings and specifications

Supply and install cage ladder including landing step, connecting plates
and all fixing accessories and support as drawing and specification

R Cage Ladder nos -

TA2459 Lesaffre Garuda 14/75 23de-38a4-c013-c37e-2.5


Item BILL NO. 50 50.5 METALS
Qty. Unit Rate Rupiahs
No INSTANT DRY YEAST

To Collection Rp. -

COLLECTIONS

Page 50.5/1 -

Page 50.5/2 -

TA2459 Lesaffre Garuda 15/75 23de-38a4-c013-c37e-2.5


Item BILL NO. 50 50.5 METALS
Qty. Unit Rate Rupiahs
No INSTANT DRY YEAST

50.5 METALS
CARRIED TO SUMMARY AT END OF BILL NO. 50 Rp. -

TA2459 Lesaffre Garuda 16/75 23de-38a4-c013-c37e-2.5


Item BILL NO. 50 50.7 THERMAL AND MOISTURE Qty Unit Rate Rupiahs
No. INSTANT DRY YEAST PROTECTION

50.7.1 FLASHING AND SHEET METAL

Supply and Install Waterstop Colorbond finish fixed to metal roof sheet,
including sealant and all necessary fixing accessories; all in accordance with
drawings and specifications

A To Roof m -

Supply and Install Metal cladding Trimdek 0.45 BMT finish colorbond
fixed to steel structure, including sealant, over flow galvanized steel pipe
Ø2" 6000mm CTC, and all necessary fixing accessories; all in accordance
with drawings and specifications

B To Fascia m2 -

Supply and Install Metal Flashing 0.45 BMT finish colorbond fixed to steel
purlin, including sealant and all necessary fixing accessories; all in
accordance with drawings and specifications

C To Roof m -

50.7.2 ROOF SPECIALITIES

Supply and Install metal gutter 0.5mm with weatherproof sealant complete
with plate support, jointing and all necessary fixing accessories and support,
in accordance with manufacturer's recommendations, as drawings and
specifications

D To Roof Gutter m2 -

Supply and Install down pipe complete with overflow, steel clamp, support,
fitting, bracket, steel unp, and all fixing accessories; all in accordance with
drawings and specifications

E PVC Downpipe Ø4" m -

F Cast iron roof drain nos -

G Chromium roof drain strainer nos -

Supply and install concrete waterproofing liquid membrane complete with


accessories and support; all in accordance with manufacturer's instruction,
drawings, and specifications

H To Roof m2 -

Supply and install waterproofing membrane polyurethane complete with


accessories and support; all in accordance with manufacturer's instruction,
drawings, and specifications

I To Roof m2 -

50.7 THERMAL AND MOISTURE PROTECTION

TA2459 Lesaffre Garuda 17/75 23de-38a4-c013-c37e-2.7


Item BILL NO. 50 50.7 THERMAL AND MOISTURE Qty Unit Rate Rupiahs
No. INSTANT DRY YEAST PROTECTION
CARRIED TO SUMMARY AT END OF BILL NO. 50 Rp. -

TA2459 Lesaffre Garuda 18/75 23de-38a4-c013-c37e-2.7


Item BILL NO. 50
50.8 DOORS AND WINDOWS Qty. Unit Rate Rupiahs
No. INSTANT DRY YEAST

50.8.1 DOORS

Supply and install high speed doors including frames, hardwares, treshold,
steel plate, and all necessary accessories and fixing supports as drawings
and specifications

A 50.DA.023 nos -

B 50.DA.024 nos -

C 50.DA.026 nos -

D 50.DA.031 nos -

E 50.DA.033 nos -

F 50.DA.035 nos -

G 50.DA.040 nos -

H 50.DA.042 nos -

I 50.DA.044 nos -

Supply and install sectional doors including dock shelter, frames,


hardwares, treshold, steel plate, and all necessary accessories and fixing
supports as drawings and specifications

J 50.DB.046 nos -

K 50.DB.047 nos -

Supply and install sandwih panel including frames, hardwares, treshold,


steel plate, and all necessary accessories and fixing supports as drawings
and specifications

L 50.DC.028 nos -

M 50.DC.045 nos -

Supply and install fire shutter doors including frames, hardwares, treshold,
steel plate, and all necessary accessories and fixing supports as drawings
and specifications

N 50.DD.030 nos -

O 50.DD.032 nos -

P 50.DD.034 nos -

Supply and install steel doors including frames, hardwares, treshold, steel
plate, and all necessary accessories and fixing supports as drawings and
specifications

Q 50.DE.001 nos -

R 50.DE.002 nos -

TA2459 Lesaffre Garuda 19/75 23de-38a4-c013-c37e-2.8


Item BILL NO. 50
50.8 DOORS AND WINDOWS Qty. Unit Rate Rupiahs
No. INSTANT DRY YEAST

To Collection Rp. -

50.8.1 DOORS, CONT'D

Supply and install steel doors including frames, hardwares, treshold, steel
plate, and all necessary accessories and fixing supports as drawings and
specifications

A 50.DE.008 nos -

B 50.DF.062 nos -

Supply and install steel door including vision panel / louvre, frames,
hardwares, treshold, steel plate, and all fixing accessories and supports as
drawings and specifications

C 50.DG.004 nos -

D 50.DG.006 nos -

E 50.DG.022 nos -

F 50.DG.063 nos -

Supply and install steel door including tempered and clear glass, vision
panel / louvre, frames, hardwares, treshold, steel plate, and all fixing
accessories and supports as drawings and specifications

G 50.DH.007 nos -

H 50.DH.016 nos -

I 50.DH.018 nos -

J 50.DH.064 nos -

Supply and install alumnium door including tempered and clear glass,
vision panel / louvre, frames, hardwares, treshold, steel plate, and all fixing
accessories and supports as drawings and specifications

K 50.DK.009 nos -

L 50.DK.010 nos -

Supply and install steel door including frames, hardwares, treshold, steel
plate, and all fixing accessories and supports as drawings and specifications

M 50.DL.017 nos -

N 50.DL.027 nos -

O 50.DL.037 nos -

P 50.DL.038 nos -

Q 50.DL.039 nos -

R 50.DL.065 nos -

TA2459 Lesaffre Garuda 20/75 23de-38a4-c013-c37e-2.8


Item BILL NO. 50
50.8 DOORS AND WINDOWS Qty. Unit Rate Rupiahs
No. INSTANT DRY YEAST
S 50.DL.066 nos -

To Collection Rp. -

50.8.1 DOORS, CONT'D

Supply and install steel door including frames, hardwares, treshold, steel
plate, and all fixing accessories and supports as drawings and specifications

A 50.DL.070 nos -

B 50.DL.073 nos -

C 50.DL.074 nos -

D 50.DL.075 nos -

Supply and install steel door including temperedand clear glass, vision
panel / louvre, frames, hardwares, treshold, steel plate, and all fixing
accessories and supports as drawings and specifications

E 50.DN.052 nos -

F 50.DN.077 nos -

Supply and install steel firerated door including frames, hardwares,


treshold, steel plate, and all fixing accessories and supports as drawings and
specifications
G 50.DV.036 nos -

Supply and install alumnium door including frames, hardwares, treshold,


steel plate, and all fixing accessories and supports as drawings and
specifications
H 50.DP.003 nos -

I 50.DW.005 nos -

Supply and install alumnium door including vision panel / louvre, frames,
hardwares, treshold, steel plate, and all fixing accessories and supports as
drawings and specifications

J 50.DQ.011 nos -

K 50.DQ.012 nos -

L 50.DQ.013 nos -

M 50.DQ.014 nos -

N 50.DQ.015 nos -

O 50.DQ.048 nos -

P 50.DQ.051 nos -

Q 50.DQ.053 nos -

R 50.DQ.055 nos -

TA2459 Lesaffre Garuda 21/75 23de-38a4-c013-c37e-2.8


Item BILL NO. 50
50.8 DOORS AND WINDOWS Qty. Unit Rate Rupiahs
No. INSTANT DRY YEAST

To Collection Rp. -

50.8.1 DOORS, CONT'D

Supply and install alumnium door including tempered and clear glass,
vision panel / louvre, frames, hardwares, treshold, steel plate, and all fixing
accessories and supports as drawings and specifications

A 50.DR.019 nos -

B 50.DR.020 nos -

C 50.DR.021 nos -

D 50.DR.025 nos -

E 50.DR.029 nos -

F 50.DR.041 nos -

G 50.DR.043 nos -

H 50.DR.049 nos -

I 50.DR.050 nos -

J 50.DR.054 nos -

K 50.DR.056 nos -

L 50.DR.059 nos -

M 50.DR.060 nos -

N 50.DR.061 nos -

O 50.DR.067 nos -

P 50.DR.068 nos -

Q 50.DR.069 nos -

R 50.DR.071 nos -

S 50.DR.072 nos -

T 50.DR.076 nos -

Supply and install alumnium glass door including frames, hardwares,


treshold, steel plate, and all fixing accessories and supports as drawings and
specifications
U 50.DU.057 nos -

TA2459 Lesaffre Garuda 22/75 23de-38a4-c013-c37e-2.8


Item BILL NO. 50
50.8 DOORS AND WINDOWS Qty. Unit Rate Rupiahs
No. INSTANT DRY YEAST
V 50.DX.058 nos -

To Collection Rp. -

50.8.2 WINDOWS

Supply and install aluminium fix window complete with laminated


tempered glass + clear glass, hardwares, and all necessary components,
fixing, accessories as drawing and specification.

A 50.WA.011 nos -

B 50.WA.012 nos -

C 50.WA.013 nos -

D 50.WA.014 nos -

E 50.WA.015 nos -

F 50.WA.016 nos -

G 50.WA.017 nos -

Supply and install aluminium swing window complete with laminated


tempered glass + clear glass, hardwares, and all necessary components,
fixing, accessories as drawing and specification.

H 50.WB.001 nos -

I 50.WB.002 nos -

J 50.WB.003 nos -

K 50.WB.004 nos -

L 50.WB.005 nos -

M 50.WB.006 nos -

N 50.WB.007 nos -

O 50.WB.008 nos -

P 50.WB.009 nos -

Q 50.WB.018 nos -

R 50.WB.019 nos -

S 50.WB.020 nos -

TA2459 Lesaffre Garuda 23/75 23de-38a4-c013-c37e-2.8


Item BILL NO. 50
50.8 DOORS AND WINDOWS Qty. Unit Rate Rupiahs
No. INSTANT DRY YEAST
T 50.WB.021 nos -

U 50.WB.010 nos -

To Collection Rp. -

50.8.3 LOUVRES

Supply and install steel louvre complete with removable insect screen,
hardwares, and all necessary components, fixing, accessories as drawing
and specification.

A 50.LA.001 nos -

B 50.LA.002 nos -

C 50.LA.003 nos -

D 50.LA.004 nos -

E 50.LA.005 nos -

F 50.LA.006 nos -

G 50.LA.007 nos -

H 50.LA.008 nos -

I 50.LA.009 nos -

J 50.LA.010 nos -

50.8.4 CURTAIN WALL

Supply and install curtain wall system complete with hardwares, and all
necessary components, fixing, accessories as drawing and specification

K 50.SR.001 nos -

To Collection Rp. -

COLLECTIONS

Page 50.8/1 -

Page 50.8/2 -

TA2459 Lesaffre Garuda 24/75 23de-38a4-c013-c37e-2.8


Item BILL NO. 50
50.8 DOORS AND WINDOWS Qty. Unit Rate Rupiahs
No. INSTANT DRY YEAST

Page 50.8/3 -

Page 50.8/4 -

Page 50.8/5 -

Page 50.8/6 -

50.8 DOORS AND WINDOWS


CARRIED TO SUMMARY AT END OF BILL NO. 50 Rp. -

TA2459 Lesaffre Garuda 25/75 23de-38a4-c013-c37e-2.8


Item BILL NO. 50
50.9. FINISHES Qty. Unit Rate Rupiahs
No INSTANT DRY YEAST

50.9.1 FLOOR FINISHES

Supply and install waterproofing including screed all in accordance with


manufactured instruction applied: all in accordance with drawings and
specifications
A To Floor Wet Area m2 -

B To Floor m2 -

Supply and install floor hardener all in accordance with manufactured


instruction applied: all in accordance with drawings and specifications

C To Floor m2 -

Prepare and apply anti acid/alkali/slippery tile; all in accordance with


manufacturer's instruction, drawings, and specifications

D To Floor m2 -

Prepare and apply epoxy quartz; all in accordance with manufacturer's


instruction, drawings, and specifications

E To Floor m2 -

Supply and install Homogenous Tile complete with screed, gape grouting
and all in accordance with manufactured instruction applied: all in
accordance with drawings and specifications

F To Floor m2 -

G To Skirting m -

Prepare and apply below materials to skirting wall complete with


accessories and support; all in accordance with manufactured instruction
applied: all in accordance with drawings and specifications

H PU Paint, h=100mm m

I Epoxy Mortar Round Coving R=70mm m

J Hardening, h=100mm m

50.9.2 WALL FINISHES

Supply and install Homogenous Tile complete with screed, gape grouting
and all in accordance with manufactured instruction applied: all in
accordance with drawings and specifications

K Applied to wall m2 -

Prepare smooth and apply waterbased acrylic emulsion paint finish, in


accordance with manufacturer's recommendations, as specified to face of :

L Applied to plastered autoclaved concrete walls (Internal Wall) m2 -

M Applied to gypsum board (Internal Wall) m2 -

TA2459 Lesaffre Garuda 26/75 23de-38a4-c013-c37e-2.9


Item BILL NO. 50
50.9. FINISHES Qty. Unit Rate Rupiahs
No INSTANT DRY YEAST

To Collection Rp. -

50.9.2 WALL FINISHES, CONT'D

Prepare smooth and apply waterbased wethershield emulsion paint finish,


in accordance with manufacturer's recommendations, as specified to face of
:
A Applied to plastered autoclaved concrete walls (External Wall) m2 -

Prepare smooth and apply epoxy paint, in accordance with manufacturer's


recommendations, as drawing and specification

B Applied to wall m2 -

Prepare and apply anti acid/alkali/slippery tile; all in accordance with


manufacturer's instruction, drawings, and specifications

C Applied to wall m2 -

Supply and install waterproofing including screed all in accordance with


manufactured instruction applied: all in accordance with drawings and
specifications

D Applied to Wall Wet Area m2 -

50.9.3 CEILING FINISHES

Prepare smooth and apply waterbased acrylic emulsion paint finish, in


accordance with manufacturer's recommendations, as specified to face of :

E To Calciboard Ceiling m2 -

Prepare smooth and apply skimcoat, in accordance with manufacturer's


recommendations, as drawing and specification

F To Exposed Concrete m2 -

Prepare smooth and apply epoxy paint, in accordance with manufacturer's


recommendations, as drawing and specification

G To Exposed Concrete m2 -

To Collection Rp. -

COLLECTIONS

Page 50.9/1 -

TA2459 Lesaffre Garuda 27/75 23de-38a4-c013-c37e-2.9


Item BILL NO. 50
50.9. FINISHES Qty. Unit Rate Rupiahs
No INSTANT DRY YEAST

Page 50.9/2 -

50.9. FINISHES
CARRIED TO SUMMARY AT END OF BILL NO. 50 Rp. -

TA2459 Lesaffre Garuda 28/75 23de-38a4-c013-c37e-2.9


Item BILL NO. 50
50.10 SPECIALITIES Qty. Unit Rate Rupiahs
No INSTANT DRY YEAST

50.10.1 INTERIOR SPECIALITIES

Supply and install sanitary wares complete with all necessary in


accordance with manufacturer's recommendations as drawing and
specification
A SF1, Short Station Sink Stainless steel 304 nos -

B SF8, Wall Mounted nos -

C SF9, Toilet Cubicle nos -

D SF10, Toilet Seated nos -

E SF11, Floor Drain nos -

F SF12, Jet Shower nos -

G SF13, Urinoir nos -

H SF14, Urinal Partition nos -

I SF15, Automatic Tap nos -

J SF16, Self Closing nos -

K SF17, Under Counter Lavatory nos -

L SF18, Wall Hung Lavatory nos -

M SF19, Paper Towel Holder nos -

N SF20, Wall Mounted Shower nos -

O SF21, Shower Stop Valve nos -

P SF22, Mirror Half Body Stainless steel nos -

Q SF23, Mirror Male Toilet nos -

R SF23, Mirror Female Toilet nos -

S SF24, Soap Dispenser nos -

T SF25, Automatic Soap Dispenser nos -

U SF27, Automatic Hand Sanitizer Dispenser nos -

V SF28, Paper Towel Dispenser Stainless steel 304 nos -

W SF28, Paper Towel Dispenser nos -

50.10.2 FURNITURES

Supply and install furnitures complete with all necessary in accordance


with manufacturer's recommendations as drawing and specification

X FU02, Overall Cabinet nos -

Y FU03, Step Over Bench nos -

TA2459 Lesaffre Garuda 29/75 23de-38a4-c013-c37e-2.10


Item BILL NO. 50
50.10 SPECIALITIES Qty. Unit Rate Rupiahs
No INSTANT DRY YEAST

To Collection Rp. -

50.10.2 FURNITURES. CONT'D

Supply and install furnitures complete with all necessary in accordance


with manufacturer's recommendations as drawing and specification

A FU04, Bench nos -

B FU05, Hairnet and Mask Container nos -

C FU06, Waste Bin nos -

D FU07, Locker nos -

E FU08, Shoe Rack (for Ablution) nos -

50.10.3 SUNDRIES

F Racking system, FILO Drive in Rack, 3 tier 3 Deep, 1.5m height, plt -
including all supports and accessories as drawing specified

To Collection Rp. -

COLLECTIONS

Page 50.10/1 -

Page 50.10/2 -

TA2459 Lesaffre Garuda 30/75 23de-38a4-c013-c37e-2.10


Item BILL NO. 50
50.10 SPECIALITIES Qty. Unit Rate Rupiahs
No INSTANT DRY YEAST

50.10 SPECIALITIES
CARRIED TO SUMMARY AT END OF BILL NO. 50 Rp. -

TA2459 Lesaffre Garuda 31/75 23de-38a4-c013-c37e-2.10


Item BILL NO. 50
50.11 MECHANICAL WORKS Qty. Unit Rate Rupiahs
No INSTANT DRY YEAST

50.11 MECHANICAL WORKS

50.11.1 DOMESTIC COLD WATER

DOMESTIC COLD WATER SYSTEM INSTALLATION


Supply and install Domestic Water pipes; PPR PN 10 including fittings (for 50
mm dia. Pipe or less) fixed in position complete with seals (for underground
pipe) supports, hangers, brackets, clamp, painting, and other necessary fixing
and jointing material in accordance to the technical specification and drawings,
as described;

PIPEWORKS

A 15mm diameter pipe m

B 20mm diameter pipe m

C 25mm diameter pipe m

D 32mm diameter pipe m

E 40mm diameter pipe m

F 50mm diameter pipe m

VALVE AND ANCILLARIES

G 25mm diameter gate valve no

H 32mm diameter gate valve no

I 40mm diameter gate valve no

J 50mm diameter gate valve no

K AAV; 25mm diameter

50.11.2 SEWAGE AND WASTE WATER SYSTEM

SEWAGE AND WASTE WATER SYSTEM INSTALLATION


Supply and Install Waste water, Sewage water pipes and Venting pipes; PVC Class
AW 10 kg/m2 including fittings (for 50 mm dia. Pipe or less) fixed in position
complete with supports, hangers, brackets, clamp, painting, and other necessary
fixing and jointing material in accordance to the technical specification and
drawings, as described;

PIPEWORKS (SEWAGE AND WASTE)

L 50mm diameter pipe m

M 100mm diameter pipe m

N 160mm diameter pipe m

O 200mm diameter pipe m

TA2459 Lesaffre Garuda 32/75 23de-38a4-c013-c37e-2.11


Item BILL NO. 50
50.11 MECHANICAL WORKS Qty. Unit Rate Rupiahs
No INSTANT DRY YEAST

To Collection Rp. -

TA2459 Lesaffre Garuda 33/75 23de-38a4-c013-c37e-2.11


Item BILL NO. 50
50.11 MECHANICAL WORKS Qty. Unit Rate Rupiahs
No INSTANT DRY YEAST

50.11.2 SEWAGE AND WASTE WATER SYSTEM INSTALLATION (Cont'd)


Supply and Install Waste water, Sewage water pipes and Venting pipes; PVC Class
AW 10 kg/m2 including fittings (for 50 mm dia. Pipe or less) fixed in position
complete with supports, hangers, brackets, clamp, painting, and other necessary
fixing and jointing material in accordance to the technical specification and
drawings, as described;

PIPEWORKS (VENTING)

A 40mm diameter pipe m

B 50mm diameter pipe m

C 80mm diameter pipe m

FITTINGS

D Fitting 110mm diameter no

E Fitting 160mm diameter no

F Fitting 200mm diameter no

VALVE AND ANCILLARIES

G Ventcap 80mm diameter no

H Clean out 50mm diameter no

I Clean out 100mm diameter no

50.11.3 INDUSTRIAL WASTE WATER SYSTEM

INDUSTRIAL WASTE WATER SYSTEM INSTALLATION


Supply and Install Industrial Waste Water pipes; Stainless steel 316L schedule 10
and FRP pipe including excavation for undergground pipe and fittings (for 50mm
dia. Pipe or less) fixed in position complete with supports, hangers, brackets,
clamp,painting, and other necessary fixing a

PIPEWORKS

G 800mm diameter pipe; FRP m

H 600mm diameter pipe; FRP m

I 250mm diameter pipe m

J 150mm diameter pipe m

To Collection Rp. -

TA2459 Lesaffre Garuda 34/75 23de-38a4-c013-c37e-2.11


Item BILL NO. 50
50.11 MECHANICAL WORKS Qty. Unit Rate Rupiahs
No INSTANT DRY YEAST

TA2459 Lesaffre Garuda 35/75 23de-38a4-c013-c37e-2.11


Item BILL NO. 50
50.11 MECHANICAL WORKS Qty. Unit Rate Rupiahs
No INSTANT DRY YEAST

50.11.3 INDUSTRIAL WASTE WATER SYSTEM (CONT'D)

INDUSTRIAL WASTE WATER SYSTEM INSTALLATION


Supply and Install Industrial Waste Water pipes; Stainless steel 316L schedule 10
and FRP pipe including excavation for undergground pipe and fittings (for 50mm
dia. Pipe or less) fixed in position complete with supports, hangers, brackets,
clamp,painting, and other necessary fixing a

FITTINGS

A Fitting 800mm diameter; FRP no

B Fitting 600mm diameter; FRP no

C Fitting 250mm diameter no

D Fitting 150mm diameter no

50.11.4 HYDRANT & SPRINKLER SYSTEM

HYDRANT SYSTEM INSTALLATION


Supply and install Hydrant pipes, Black steel pipe to ASTM A 53 schedule 40 ,
Grade B, including fitting (for 50 mm dia. Pipe or less) fixed in position complete
with supports, hangers, brackets, clamp, painting, and other necessary fixing and
jointing material in accordance to the technical specification and drawings, as
described;

PIPEWORKS

E 40mm diameter pipe m

F 65mm diameter pipe m

G 80mm diameter pipe m

H 100mm diameter pipe m

I 150mm diameter pipe m

J 200mm diameter pipe m

FITTINGS

K Fitting 65mm diameter no

L Fitting 80mm diameter no

M Fitting 100mm diameter no

N Fitting 150mm diameter no

O Fitting 200mm diameter no

TA2459 Lesaffre Garuda 36/75 23de-38a4-c013-c37e-2.11


Item BILL NO. 50
50.11 MECHANICAL WORKS Qty. Unit Rate Rupiahs
No INSTANT DRY YEAST

To Collection Rp. -

TA2459 Lesaffre Garuda 37/75 23de-38a4-c013-c37e-2.11


Item BILL NO. 50
50.11 MECHANICAL WORKS Qty. Unit Rate Rupiahs
No INSTANT DRY YEAST

50.11.4 HYDRANT & SPRINKLER SYSTEM (CONT'D)

HYDRANT SYSTEM INSTALLATION


Supply and install Hydrant pipes, Black steel pipe to ASTM A 53 schedule 40 ,
Grade B, including fitting (for 50 mm dia. Pipe or less) fixed in position complete
with supports, hangers, brackets, clamp, painting, and other necessary fixing and
jointing material in accordance to the technical specification and drawings, as
described;

VALVE AND ANCILLARIES

A 80mm diameter gate valve, UL listed & FM approved no

B Portable fire extinguisher with capacity 6 kg chemical powder ABC type. no

C Portable fire extinguisher with capacity 6 kg dry chemical CO2 type. no

D Portable fire extinguisher with capacity 25 kg dry chemical CO2 type c/w trolley. no

E Indoor Hydrant Box (IHB) complete with hose rack, rubber hose, hose reel, valve no
and nozzle

SPRINKLER SYSTEM INSTALLATION


Supply and install Sprinkler pipes, Black steel pipe to ASTM A 53 schedule 40 ,
Grade B, including fitting (for 50 mm dia. Pipe or less) fixed in position complete
with supports, hangers, brackets, clamp, painting, and other necessary fixing and
jointing material in accordance to the technical specification and drawings, as
described;

PIPEWORKS

F 25mm diameter pipe m

G 32mm diameter pipe m

H 40mm diameter pipe m

I 50mm diameter pipe m

J 65mm diameter pipe m

K 80mm diameter pipe m

L 100mm diameter pipe m

M 150mm diameter pipe m

N 200mm diameter pipe m

FITTINGS

O Fitting 65mm diameter no

P Fitting 80mm diameter no

TA2459 Lesaffre Garuda 38/75 23de-38a4-c013-c37e-2.11


Item BILL NO. 50
50.11 MECHANICAL WORKS Qty. Unit Rate Rupiahs
No INSTANT DRY YEAST

To Collection Rp. -

TA2459 Lesaffre Garuda 39/75 23de-38a4-c013-c37e-2.11


Item BILL NO. 50
50.11 MECHANICAL WORKS Qty. Unit Rate Rupiahs
No INSTANT DRY YEAST

50.11.4 HYDRANT & SPRINKLER SYSTEM (CONT'D)

SPRINKLER SYSTEM INSTALLATION


Supply and install Sprinkler pipes, Black steel pipe to ASTM A 53 schedule 40 ,
Grade B, including fitting (for 50 mm dia. Pipe or less) fixed in position complete
with supports, hangers, brackets, clamp, painting, and other necessary fixing and
jointing material in accordance to the technical specification and drawings, as
described;

A Fitting 100mm diameter no

B Fitting 150mm diameter no

C Fitting 200mm diameter no

VALVE AND ANCILLARIES

D Head sprinkler pendant type no

E Head sprinkler upright type no

F Alarm Control Valve (ACV); 200mm diameter set

G Alarm Control Valve (ACV); 150mm diameter set

H Branch Control Valve (BCV); 100mm diameter set

I Branch Control Valve (BCV); 150mm diameter set

J Branch Control Valve (BCV); 200mm diameter set

K Main Control Valve (MCV); 150mm diameter set

L AAV; 25mm diameter no

M Test Drain; 50 mm diameter set

N Flexible coupling; 100mm diameter no

O Flexible coupling; 150mm diameter no

P Flexible coupling; 200mm diameter no

To Collection Rp. -

TA2459 Lesaffre Garuda 40/75 23de-38a4-c013-c37e-2.11


Item BILL NO. 50
50.11 MECHANICAL WORKS Qty. Unit Rate Rupiahs
No INSTANT DRY YEAST

TA2459 Lesaffre Garuda 41/75 23de-38a4-c013-c37e-2.11


Item BILL NO. 50
50.11 MECHANICAL WORKS Qty. Unit Rate Rupiahs
No INSTANT DRY YEAST

COLLECTION

Page 50.11 /1 -

Page 50.11 /2 -

Page 50.11 /3 -

Page 50.11 /4 -

Page 50.11 /5 -

50.11 MECHANICAL WORKS


CARRIED TO SUMMARY AT END OF BILL NO. 50 Rp. -

TA2459 Lesaffre Garuda 42/75 23de-38a4-c013-c37e-2.11


Item BILL NO. 50
50.11 MECHANICAL WORKS Qty. Unit Rate Rupiahs
No INSTANT DRY YEAST

TA2459 Lesaffre Garuda 43/75 23de-38a4-c013-c37e-2.11


Item BILL NO. 50
50.12 ELECTRICAL WORKS Qty. Unit Rate Rupiahs
No INSTANT DRY YEAST

50.12 ELECTRICAL WORKS

50.12.1 SUB DISTRIBUTION BOARDS


Supply, Install and Testing Commissioning the following Sub Distribution board
fix in position includes circuit breaker, board, busbar, digital multimeter,
contactor, surge arrester, potensial transformer, current transformer, indicator
lamp, fuse, loto, star / stop push button, and all necessary accessories in
arcondance to the technical spesification as shown on drawing, as described : -

A 50DB01 no

B 50DB02 no

C 50DB03 no

D 50DBAC01 no

50.12.2 MAIN AND SUB-MAINS CABLES


Supply and Install the following Main and Sub-Mains circuit distribution cable
run & fixed on cable tray/ladders including all necessary accessories in
arcondance to the technical spesification as shown on drawing, as described : -

E From SDB…. to 50DB01 m by other package

F From SDB…. to 50DB02 m by other package

G From SDB…. to 50DB03 m by other package

50.12.3 LIGHTING FIXTURES & POWER OUTLET


Supply and Install the following light fittings including tubes or lamps fixed in
position complete with all accessories and support in accordance with the
technical specification and drawings, as described :-

H High bay LED 75W, 10503 lm no

I High bay LED 75W, 10503 lm, c/w nicad battery duration 1 hour no

J High bay LED 90W, 11000 lm no

K High bay LED 140W, 20401 lm no

L Recessed mounted TLED 40W, 220V, 3709 lm no

M Recessed mounted TLED 40W, 220V, 3709 lm, c/w nicad battery duration 1 no
hour
N Exit sign LED 5W, 220V, wall mounted no

O Waterproof LED 20W, 220V, IP65, 2000 lm, L600 no

P Waterproof LED 20W, 220V, IP65, 2000 lm, L600, c/w nicad battery duration 1 no
hour

Q Waterproof LED 40W, 220V, IP65, 400 lm, L1200 no

To Collection Rp. -

TA2459 Lesaffre Garuda 44/75 23de-38a4-c013-c37e-2.12


Item BILL NO. 50
50.12 ELECTRICAL WORKS Qty. Unit Rate Rupiahs
No INSTANT DRY YEAST

TA2459 Lesaffre Garuda 45/75 23de-38a4-c013-c37e-2.12


Item BILL NO. 50
50.12 ELECTRICAL WORKS Qty. Unit Rate Rupiahs
No INSTANT DRY YEAST

50.12.3 LIGHTING FIXTURES & POWER OUTLET (Cont'd)


Supply and Install the following light fittings including tubes or lamps fixed in
position complete with all accessories and support in accordance with the
technical specification and drawings, as described :-

A Waterproof LED 40W, 220V, IP65, 400 lm, L1200, c/w nicad battery duration 1 no
hour

B Waterproof LED 20W, 220V, IP65, mounted on steel pipe 2.5mtr height no
Ø40mm

C Flood light LED 100W, 9400 lm no

D Downlight 16W 220V, minimum 1200 lm no

E Downlight 16W 220V, minimum 1200 lm, c/w nicad battery duration 1 hour no

F Batten LED 40W, 220V, 4100 lm no

G Batten LED 40W, 220V, 4100 lm, c/w nicad battery duration 1 hour no

H Explosion proof LED 40W, 220V, Zone-2, T6 surface mounted, minimum 4000 lm no

Supply and Install the following switches including provision of steel/metal box
and all accessories accordance with the technical specification and drawings, as
described :-

I Single gang, 1 way switch, 10A no

J Double gang, 1 way switch, 10A no

Supply and Install lighting & switch cables from sub circuit to final circuit
including grounding system and all neccessary accessories accordance with the
technical specification and drawings, as described :-

K Cabling point from local panel (400V/CU/PVC 3C x 2.5 mm² shall be UV & no
chemical resistance) run-in and with PVC high impact conduit) to; lighting and
switch

POWER OUTLET
Supply and Install the following power outlet including provision of steel/metal
box and all accessories accordance with the Technical Specification and
drawings, as described :-

L General socket outlet, wall mounted, 16A, 240V, single gang no

M General socket outlet, wall mounted, 16A, 240V, double gang no

N General socket outlet fly catcher, wall mounted, 16A, 240V, single gang no

O General socket outlet c/w cover, wall mounted, 16A, 240V, (waterproof) single no
gang

To Collection Rp. -

TA2459 Lesaffre Garuda 46/75 23de-38a4-c013-c37e-2.12


Item BILL NO. 50
50.12 ELECTRICAL WORKS Qty. Unit Rate Rupiahs
No INSTANT DRY YEAST

TA2459 Lesaffre Garuda 47/75 23de-38a4-c013-c37e-2.12


Item BILL NO. 50
50.12 ELECTRICAL WORKS Qty. Unit Rate Rupiahs
No INSTANT DRY YEAST

POWER OUTLET (Cont'd)


Supply and Install the following power outlet including provision of steel/metal
box and all accessories accordance with the Technical Specification and
drawings, as described :-

A General socket outlet hand dryer, wall mounted, 16A, 240V, (waterproof) single no
gang

B Industrial socket outlet, mounted on the front panel door, 16A, 240V, IP65, 1 Ph no

C Industrial socket outlet, mounted on the front panel door, 32A, 400V, IP65, 3 Ph no

D Industrial combination outlet, 16A, 240V, IP65, 1 Ph & 32A, 400V, IP65, 3 Ph no

50.12.4 TRAYS AND LADDERS


Supply and Install hot dip galvanized tray and ladder 2mm thickness include
jointing, elbow, tee, fixing accessories and hangers and all necessary accessories
accordance with the technical specification and drawings, as described :-

Electrical

E Cable tray 300x100mm m

F Cable tray 200x100mm m

G Wiremesh tray 300x100mm m

Electronic

H Cable tray 200x100mm m

I Wiremesh tray 200x100mm m

50.12.5 GROUNDING & LIGHTNING PROTECTION SYSTEM


Supply and Install Grounding system for panel and equipment complete with
support and all neccessary accessories accordance with the technical
specification and drawings, as described :-

J Earth pit, Conductor clamp and rod electrode, dia 19mm x 3000 length no

K Earthing bonding bar (copper bar) 40x3mm thk, c/w isolator no

L BC 70mm2, grounding cable for main/mesh earthing c/w connector and m


grounding lug

M Potential earth clamp (100kA) m

N Bonding cable NYAF 16mm2 m

O Bonding cable NYAF 25mm2 m

P Bonding cable NYAF 35mm2 m

Q Bonding cable NYAF 40mm2 m

To Collection Rp. -

TA2459 Lesaffre Garuda 48/75 23de-38a4-c013-c37e-2.12


Item BILL NO. 50
50.12 ELECTRICAL WORKS Qty. Unit Rate Rupiahs
No INSTANT DRY YEAST

TA2459 Lesaffre Garuda 49/75 23de-38a4-c013-c37e-2.12


Item BILL NO. 50
50.12 ELECTRICAL WORKS Qty. Unit Rate Rupiahs
No INSTANT DRY YEAST

50.12.6 FIRE ALARM


Supply and Install the following Fire Alarm Equipment complete with support, and
all necessary accessories in accordance to the technical specification and
drawings, as described : -

A JBFA-40-01 no

B Addressable photoelectric smoke detector no

C Addressable manual call point no

D Horn & strobe light no

E Flow switch sprnkler system no

F Tamper switch sprnkler system no

G End of line (EOL) no

Supply and Install the following Fire Alarm cables in final sub-circuit to
termination, run-in and with steel conduit 20mm dia; including earthing system
and all necessary accessories in accordance to the technical spesification as
shown on drawing, as described : -

H Power Cable FRC 2Cx2,5 mm2; from control room BD40 m

I Cable FRC STP 2Cx1,5 mm2; for detector point no

J Cable FRC STP 2Cx1,5 mm2; for manual call point no

K Cable FRC 2Cx1,5 mm2; for horn & strobe light point no

50.12.7 PUBLIC ADDRESS


Supply and Install the following Sound System Equipment complete with support,
and all necessary accessories in accordance to the technical specification and
drawings, as described : -

L Wall mounted switch rack JBPA-40-01 (SR-40-01) no

M Indoor ceiling mounted speaker 6W no

N Horn speaker 15W no

O Column speaker 10W no

P Box speaker 6W no

Supply and Install the following Public Address cables in final sub-circuit to
termination, run-in and with steel conduit 20mm dia; including earthing system
and all necessary accessories in accordance to the technical spesification as
shown on drawing, as described : -

Q Cable FO OM3; from BD96 m

R Cable NYMHY 2Cx1,5 mm2; for column speaker point no

To Collection Rp. -

TA2459 Lesaffre Garuda 50/75 23de-38a4-c013-c37e-2.12


Item BILL NO. 50
50.12 ELECTRICAL WORKS Qty. Unit Rate Rupiahs
No INSTANT DRY YEAST

TA2459 Lesaffre Garuda 51/75 23de-38a4-c013-c37e-2.12


Item BILL NO. 50
50.12 ELECTRICAL WORKS Qty. Unit Rate Rupiahs
No INSTANT DRY YEAST

50.12.7 PUBLIC ADDRESS (Cont'd)


Supply and Install the following Public Address cables in final sub-circuit to
termination, run-in and with steel conduit 20mm dia; including earthing system
and all necessary accessories in accordance to the technical spesification as
shown on drawing, as described : -

A Cable NYMHY 2Cx1,5 mm2; for indor ceiling speaker point no

B Cable NYMHY 2Cx1,5 mm2; for horn speaker point no

C Cable NYMHY 2Cx1,5 mm2; for column speaker point no

D Cable NYMHY 2Cx1,5 mm2; for box speaker point no

50.12.8 DATA AND TELEPHONE


Supply and Install the following Data and Communication System
Equipment complete with support, and all necessary accessories in
accordance to the technical specification and drawings, as described : -

E Wall mounted switch rack SR-40-01 no

F Single gang type data outlet (RJ45) no

G Single gang type telephone outlet (RJ45) no

Supply and Install the following Data and Telephone cables in final sub-circuit
to termination, run-in and with steel conduit 20mm dia; including earthing system
and all necessary accessories in accordance to the technical spesification as
shown on drawing, as described : -

G Cable UTP-CAT6/FO mm2; for data outlet point no

H Cable UTP-CAT6/FO mm2; for telephone outlet point no

I Cable FO OM3; from BD96 m

50.12.9 SECURITY SYSTEM


Supply and Install the following Security System Equipment complete with
support, and all necessary accessories in accordance to the technical specification
and drawings, as described : -

I Wall mounted switch rack SR-40-01 no

J IP based bullet fix camera indoor type no

K IP based bullet fix camera outdoor type no

L IP based dome camera no

M Acces control door consist of; no


Door control
Finger print / card reader
Push button door release

To Collection Rp. -

TA2459 Lesaffre Garuda 52/75 23de-38a4-c013-c37e-2.12


Item BILL NO. 50
50.12 ELECTRICAL WORKS Qty. Unit Rate Rupiahs
No INSTANT DRY YEAST

TA2459 Lesaffre Garuda 53/75 23de-38a4-c013-c37e-2.12


Item BILL NO. 50
50.12 ELECTRICAL WORKS Qty. Unit Rate Rupiahs
No INSTANT DRY YEAST

50.12.9 SECURITY SYSTEM (Cont'd)


Supply and Install the following Security cables in final sub-circuit to
termination, run-in and with PVC conduit 25mm dia underground direct burried
min 400mm below grade or through pipe rack; including earthing system and all
necessary accessories in accordance to the technical spesification as shown on
drawing, as described : -

A Cable UTP-CAT6/FO; for bullet fix camera indoor type point no

B Cable UTP-CAT6/FO; for bullet fix camera outdoor type point no

C Cable UTP-CAT6/FO; for dome camera point no

D Cable UTP-CAT6/FO; for acces control door point no

E Cable FO OM3; from BD96 m

To Collection Rp. -

COLLECTIONS

Page 50.12 /1 -

Page 50.12 /2 -

Page 50.12 /3 -

Page 50.12 /4 -

Page 50.12 /5 -

Page 50.12 /6 -

50.12 ELECTRICAL WORKS


CARRIED TO SUMMARY AT END OF BILL NO. 50 Rp. -

TA2459 Lesaffre Garuda 54/75 23de-38a4-c013-c37e-2.12


Item BILL NO. 50
50.12 ELECTRICAL WORKS Qty. Unit Rate Rupiahs
No INSTANT DRY YEAST

TA2459 Lesaffre Garuda 55/75 23de-38a4-c013-c37e-2.12


Item BILL NO. 50
50.13 HVAC WORKS Qty. Unit Rate Rupiahs
No INSTANT DRY YEAST

50.13 ELECTRICAL WORKS

50.13.1 EQUIPMENT

AHU UNIT
Supply and Install of AHU Units complete with hangers/supports,
vibration mountings, neoprene pads and all necessary accessories in
accordance to the technical specification and drawings, as described : -

A AHU-50.02.01, modular hygienic class, chilled water coil type, total no


cooling capacity 435 kWth, supply air flow 21.303 m3/hr, pressure drop
100 pa

B AHU-50.02.02, modular hygienic class, chilled water coil type, total no


cooling capacity 341 kWth, supply air flow 33.224 m3/hr, pressure drop
100 pa

C AHU-50.02.03, modular hygienic class, VRF type, total cooling capacity no


51 kWth, supply air flow 14.450 m3/hr, pressure drop 100 pa, refrigerant
R-410A

D AHU-50.02.04, modular hygienic class, VRF type, total cooling capacity no


42,5 kWth, supply air flow 11.420 m3/hr, pressure drop 100 pa,
refrigerant R-410A

E AHU-50.02.05A-B, modular hygienic class, VRF type, total cooling no


capacity 42 kWth, supply air flow 9.626 m3/hr, pressure drop 100 pa,
refrigerant R-410A

F OU-VRF.50.02.02; VRF air cooled type, cooling capacity 51-68 kWth, no


380V/3Ph/50Hz

G OU-VRF.50.02.03; VRF air cooled type, cooling capacity 42-61.5 kWth, no


380V/3Ph/50Hz

H OU-VRF.50.02.04A-B; VRF air cooled type, cooling capacity 84-115 kWth, no


380V/3Ph/50Hz

COLD ROOM
Supply and Install of Cold Room Units complete with all necessary
accessories in accordance to the technical specification and drawings, as
described : -

I COLD ROOM Unit no


Room Area. M2 180
Room Height, M 5.5
Outside Temp, oC 35
Outside RH, % 65
Room Temp, oC 0.5 ~ 1
No. People Est. 4
Product Capacity, Ton 12
Daily Turnover Est., % 20
Refrigerant R404A

To Collection Rp. -

TA2459 Lesaffre Garuda 56/75 23de-38a4-c013-c37e-2.13


Item BILL NO. 50
50.13 HVAC WORKS Qty. Unit Rate Rupiahs
No INSTANT DRY YEAST

TA2459 Lesaffre Garuda 57/75 23de-38a4-c013-c37e-2.13


Item BILL NO. 50
50.13 HVAC WORKS Qty. Unit Rate Rupiahs
No INSTANT DRY YEAST

50.13.1 EQUIPMENT (Cont'd)

VRF UNIT
Supply and Install of VRF Units complete with hangers/supports, vibration
mountings, neoprene pads and all necessary accessories in accordance to
the technical specification and drawings, as described : -

A IU-VRF.50.00.01; 4 way cassete, cooling capacity 2.7kWth, supply no


air flow 760 CMH, free blow, 0.37kW, 220V/1Ph/50Hz

B IU-VRF.50.00.02; high static split duct, cooling capacity 7.1kWth, supply no


air flow 1140 CMH, static pressure 220 pa, 0.37kW, 220V/1Ph/50Hz

C IU-VRF.50.00.03; wall mounted, cooling capacity 2.8kWth, supply air no


flow 354 CMH, free blow, 0.37kW, 220V/1Ph/50Hz

D IU-VRF.50.00.04; high static split duct, cooling capacity 16kWth, supply no


air flow 855 CMH, static pressure 220 pa, 0.37kW, 220V/1Ph/50Hz

E IU-VRF.50.00.05; high static split duct, cooling capacity 22kWth, supply no


air flow 1358 CMH, static pressure 220 pa, 1.1kW, 220V/1Ph/50Hz

F IU-VRF.50.00.06; high static split duct, cooling capacity 28kWth, supply no


air flow 2037 CMH, static pressure 220 pa, 1.1kW, 220V/1Ph/50Hz

G IU-VRF.50.02.01; 1 way cassete, cooling capacity 2.6kWth, supply air no


flow 558 CMH, free blow, 0.1kW, 220V/1Ph/50Hz

H IU-VRF.50.02.02; 2 way cassete, cooling capacity 2.3kWth, supply air no


flow 570 CMH, free blow, 0.1kW, 220V/1Ph/50Hz

I IU-VRF.50.02.03; 4 way cassete, cooling capacity 5kWth, supply air no


flow 672 CMH, free blow, 0.1kW, 220V/1Ph/50Hz

J OU-VRF.50.00.01; Air cooled VRF, cooling capacity 28.6-55.6 kWth, supply air no
flow 9600 CMH/fan, 380V/3Ph/50Hz

K OU-VRF.50.00.02; Air cooled VRF, cooling capacity 49-68 kWth, supply air no
flow 9600 CMH/fan, 380V/3Ph/50Hz

L OU-VRF.50.02.01; Air cooled VRF, cooling capacity 11-14 kWth, supply air no
flow 6600 CMH/fan, 220V/1Ph/50Hz

DX UNIT
Supply and Install of DX Units complete with hangers/supports, vibration
mountings, neoprene pads and all necessary accessories in accordance to
the technical specification and drawings, as described : -

M IU-DX.50.00.01A&B; ceiling suspend, cooling capacity 7.1kWth, supply no


air flow 1520 CMH, 0.1kW, 220V/1Ph/50Hz

N IU-DX.50.00.02A&B; ceiling suspend, cooling capacity 5.7kWth, supply no


air flow 720 CMH, 0.1kW, 220V/1Ph/50Hz

To Collection Rp. -

TA2459 Lesaffre Garuda 58/75 23de-38a4-c013-c37e-2.13


Item BILL NO. 50
50.13 HVAC WORKS Qty. Unit Rate Rupiahs
No INSTANT DRY YEAST

TA2459 Lesaffre Garuda 59/75 23de-38a4-c013-c37e-2.13


Item BILL NO. 50
50.13 HVAC WORKS Qty. Unit Rate Rupiahs
No INSTANT DRY YEAST

50.13.1 EQUIPMENT (Cont'd)

DX UNIT
Supply and Install of DX Units complete with hangers/supports, vibration
mountings, neoprene pads and all necessary accessories in accordance to
the technical specification and drawings, as described : -

A IU-DX.50.00.03A&B; wall mounted, cooling capacity 2.2kWth, supply no


air flow 564 CMH, 0.1kW, 220V/1Ph/50Hz

B IU-DX.50.02.01A&B; wall mounted, cooling capacity 4.0kWth, supply no


air flow 858 CMH, 0.1kW, 220V/1Ph/50Hz

C OU-DX.50.00.01A&B; air cooled inverter, cooling capacity 7.1kWth, supply no


air flow 1350 CMH, 3.5kW, 220V/1Ph/50Hz

D OU-DX.50.00.02A&B; air cooled inverter, cooling capacity 5.7kWth, supply no


air flow 1350 CMH, 2.2kW, 220V/1Ph/50Hz

E OU-DX.50.00.03A&B; air cooled inverter, cooling capacity 2.2kWth, supply no


air flow 522 CMH, 1.1kW, 220V/1Ph/50Hz

F OU-DX.50.02.01A&B; air cooled inverter, cooling capacity 4.0kWth, supply no


air flow 564 CMH, 1.5kW, 220V/1Ph/50Hz

DUCT HEATER
Supply and Install of Duct Heater Units complete with hangers/supports,
vibration mountings, neoprene pads and all necessary accessories in
accordance to the technical specification and drawings, as described : -

G EDH-50.1, heating cap 2.9kWth, supply air flow 479 CMH, 380V/3Ph/50Hz no

H EDH-50.2, heating cap 3.4kWth, supply air flow 567 CMH, 380V/3Ph/50Hz no

I EDH-50.2.2.1, heating cap 10.2kWth, supply air flow 2029 CMH, no


380V/3Ph/50Hz

FAN
Supply and Install of Fan Units complete with hangers/supports, vibration
mountings, neoprene pads and all necessary accessories in accordance to
the technical specification and drawings, as described : -

J Exhasut Fan EF-50.00.01, centrifugal with accoustic case type, cap 1755 CMH, no
static pressure 406.7 pa, 0.37kW, 220V/1Ph/50Hz

K Exhasut Fan EF-50.00.02A&B, axial wall mounted type, cap 4738 CMH, static no
pressure 83.3 pa, 0.37kW, 380V/3Ph/50Hz

L Exhasut Fan EF-50.00.03, axial wall mounted type, cap 1225 CMH, static no
pressure 98 pa, 0.37kW, 380V/3Ph/50Hz

M Exhasut Fan EF-50.00.04, ceiling mounted type, cap 63 CMH, static pressure no
N/A pa, 0.1kW, 220V/1Ph/50Hz

N Exhasut Fan EF-50.00.05, single inlet centrifugal type, cap 2468 CMH, static no
pressure 313.6 pa, 1.1kW, 380V/3Ph/50Hz

To Collection Rp. -

TA2459 Lesaffre Garuda 60/75 23de-38a4-c013-c37e-2.13


Item BILL NO. 50
50.13 HVAC WORKS Qty. Unit Rate Rupiahs
No INSTANT DRY YEAST

TA2459 Lesaffre Garuda 61/75 23de-38a4-c013-c37e-2.13


Item BILL NO. 50
50.13 HVAC WORKS Qty. Unit Rate Rupiahs
No INSTANT DRY YEAST

50.13.1 EQUIPMENT (Cont'd)

FAN
Supply and Install of Fan Units complete with hangers/supports, vibration
mountings, neoprene pads and all necessary accessories in accordance to
the technical specification and drawings, as described : -

A Exhasut Fan EF-50.00.06, mixflow inline type, cap 867 CMH, static pressure no
205.8 pa, 0.37kW, 220V/1Ph/50Hz

B Exhasut Fan EF-50.00.07, centrifugal with accoustic case, cap 2591 CMH, no
static pressure 294 pa, 0.37kW, 220V/1Ph/50Hz

C Exhasut Fan EF-50.02.01, axial wall mounted type, cap 733 CMH, static no
pressure 166.6 pa, 0.37kW, 380V/3Ph/50Hz

D Exhasut Fan EF-50.02.02, inlet circular duct type, cap 171 CMH, static pressure no
156.8 pa, 0.37kW, 220V/1Ph/50Hz

E Exhasut Fan EF-50.03.01, axial wall mounted type, cap 821 CMH, static no
pressure 166.6 pa, 0.37kW, 380V/3Ph/50Hz

50.13.2 DUCTWORK
Supply and Install galvanized steel sheet ductworks complete with
hangers, supports, brackets and all necessary fixing accessories in
accordance to the technical tpecification and drawings, as described :-

SUPPLY AIR DUCT


With external insulation (closed cell elastomeric fire retardant type class 0,
FM Approved, 50mm thickness + AL sheet Jacketing 0.4mm thckness)

F Supply air duct (SAD) ; 1200mm diameter m

G Supply air duct (SAD) ; 1000mm diameter m

H Supply air duct (SAD) ; 900mm diameter m

I Supply air duct (SAD) ; 800mm diameter m

J Supply air duct (SAD) ; 750mm diameter m

K Supply air duct (SAD) ; 700mm diameter m

L Supply air duct (SAD) ; 650mm diameter m

M Supply air duct (SAD) ; 250mm diameter m

N Supply air duct (SAD) ; 200mm diameter m

O Supply air duct (SAD) ; 400x400mm m

P Supply air duct (SAD) ; 300x300mm m

Q Supply air duct (SAD) ; 250x200mm m

R Supply air duct (SAD) ; 200x200mm m

S Supply air duct (SAD) ; 200x150mm m

TA2459 Lesaffre Garuda 62/75 23de-38a4-c013-c37e-2.13


Item BILL NO. 50
50.13 HVAC WORKS Qty. Unit Rate Rupiahs
No INSTANT DRY YEAST

To Collection Rp. -

TA2459 Lesaffre Garuda 63/75 23de-38a4-c013-c37e-2.13


Item BILL NO. 50
50.13 HVAC WORKS Qty. Unit Rate Rupiahs
No INSTANT DRY YEAST

50.13.2 DUCTWORK (Cont'd)

SUPPLY AIR DUCT


Install Textile Fabric duct including with support/rail and similar to it,
fittings & another accessories which are comply to clean room installation
requirement standard in accordance to the technical tpecification and
drawings, as described :-

A Supply air duct (SAD) ; 1000mm diameter m

B Supply air duct (SAD) ; 900mm diameter m

C Supply air duct (SAD) ; 750mm diameter m

D Supply air duct (SAD) ; 650mm diameter m

E Supply air duct (SAD) ; 500mm diameter m

F Supply air duct (SAD) ; 450mm diameter m

G Supply air duct (SAD) ; 250mm diameter m

FRESH AIR DUCT


With external insulation (closed cell elastomeric fire retardant type class 0,
FM Approved, 32mm thickness + AL sheet Jacketing 0.4mm thckness)

H Fresh air duct (FAD) ; 1200mm diameter m

I Fresh air duct (FAD) ; 300x250mm m

J Fresh air duct (FAD) ; 250x250mm m

K Fresh air duct (FAD) ; 250x200mm m

L Fresh air duct (FAD) ; 150x150mm m

RETURN AIR DUCT


With external insulation (closed cell elastomeric fire retardant type class 0,
FM Approved, 32mm thickness + AL sheet Jacketing 0.4mm thckness)

M Return air duct (RAD) ; 900mm diameter m

N Return air duct (RAD) ; 800mm diameter m

O Return air duct (RAD) ; 700mm diameter m

P Return air duct (RAD) ; 650mm diameter m

Q Return air duct (RAD) ; 500mm diameter m

R Return air duct (RAD) ; 250x200mm m

S Return air duct (RAD) ; 200x200mm m

T Return air duct (RAD) ; 200x150mm m

TA2459 Lesaffre Garuda 64/75 23de-38a4-c013-c37e-2.13


Item BILL NO. 50
50.13 HVAC WORKS Qty. Unit Rate Rupiahs
No INSTANT DRY YEAST

To Collection Rp. -

TA2459 Lesaffre Garuda 65/75 23de-38a4-c013-c37e-2.13


Item BILL NO. 50
50.13 HVAC WORKS Qty. Unit Rate Rupiahs
No INSTANT DRY YEAST

50.13.2 DUCTWORK (Cont'd)

RETURN AIR DUCT


Install Textile Fabric duct including with support/rail and similar to it, fittings &
another accessories which are comply to clean room installation
requirement standard in accordance to the technical tpecification and
drawings, as described :-

A Return air duct (RAD) ; 1100x550mm m

B Return air duct (RAD) ; 1200x600mm m

EXHAUST AIR DUCT


With external insulation (closed cell elastomeric fire retardant type class 0,
FM Approved, 25mm thickness + AL sheet Jacketing 0.4mm thckness)

C Exhaust air duct (EAD) ; 700mm diameter m

D Exhaust air duct (EAD) ; 500mm diameter m

E Exhaust air duct (EAD) ; 200mm diameter m

F Exhaust air duct (EAD) ; 500x300mm m

G Exhaust air duct (EAD) ; 400x300mm m

H Exhaust air duct (EAD) ; 300x300mm m

I Exhaust air duct (EAD) ; 300x250mm m

J Exhaust air duct (EAD) ; 250x200mm m

K Exhaust air duct (EAD) ; 200x200mm m

L Exhaust air duct (EAD) ; 150x150mm m

50.13.3 GRILLE AND DIFFUSER

Supply and Install Diffuser, Grilles and Volume Damper complete with air
equalising deflector blades, plenum box (if any) and all necessary
accessories including fixing, frame and connecting to ductwork in
accordance with the technical specification and drawings, as described :-

M Supply air diffuser (SAD) ; 400x400mm no

N Supply air grille (SAG) ; 325x225mm no

O Intake air louvre (IAL) ; 400x330mm no

P Fresh air louvre (FAL) ; 660x330mm no

Q Exhaust air grille (EAG) ; 150x150mm no

R Exhaust air grille (EAG) ; 200x200mm no

TA2459 Lesaffre Garuda 66/75 23de-38a4-c013-c37e-2.13


Item BILL NO. 50
50.13 HVAC WORKS Qty. Unit Rate Rupiahs
No INSTANT DRY YEAST

To Collection Rp. -

TA2459 Lesaffre Garuda 67/75 23de-38a4-c013-c37e-2.13


Item BILL NO. 50
50.13 HVAC WORKS Qty. Unit Rate Rupiahs
No INSTANT DRY YEAST

50.13.3 GRILLE AND DIFFUSER (Cont'd)

Supply and Install Diffuser, Grilles and Volume Damper complete with air
equalising deflector blades, plenum box (if any) and all necessary
accessories including fixing, frame and connecting to ductwork in
accordance with the technical specification and drawings, as described :-

A Exhaust air grille (EAG) ; 225x225mm no

B Exhaust air grille (EAG) ; 325x225mm no

C Exhaust air grille (EAG) ; 525x525mm no

D Exhaust air louvre (EAL) ; 400x330mm no

E Exhaust air louvre (EAL) ; 660x400mm no

F Exhaust air louvre (EAL) ; 800x495mm no

G Volume control damper (VCD) ; 150x150mm no

H Volume control damper (VCD) ; 200x150mm no

I Volume control damper (VCD) ; 200x200mm no

50.13.4 REFRIGERANT & DRAIN PIPES


Supply and install the following Refrigerant Copper Pipeworks including
FM Approved insulation ,vapour barrier, trap, fittings (for 50mm diameter
pipe or less), joints, flanges, support and all accessories in accordance to
the technical specification and drawings, as described : -

J 6.5 mm diameter pipe copper c/w insulation m

K 9,5 mm diameter pipe copper c/w insulation m

L 12,7 mm diameter pipe copper c/w insulation m

M 15,8 mm diameter pipe copper c/w insulation m

N 22,2 mm diameter pipe copper c/w insulation m

O 28,5 mm diameter pipe copper c/w insulation m

DRAIN PIPES
P 25 mm diameter pipe PVC Class AW c/w insulation m

Q 32 mm diameter pipe PVC Class AW c/w insulation m

TA2459 Lesaffre Garuda 68/75 23de-38a4-c013-c37e-2.13


Item BILL NO. 50
50.13 HVAC WORKS Qty. Unit Rate Rupiahs
No INSTANT DRY YEAST

To Collection Rp. -

TA2459 Lesaffre Garuda 69/75 23de-38a4-c013-c37e-2.13


Item BILL NO. 50
50.13 HVAC WORKS Qty. Unit Rate Rupiahs
No INSTANT DRY YEAST

50.13.5 HVAC CONTROL


Supply and Install of HVAC Control complete with all necessary accessories in
accordance to the technical specification and drawings, as described : -

A SYSTEM SOFTWARE, SERVER


1. UPS APC 3kVA/2700W, 15 minutes backup time, 1 phase, rack mount 2U, no
10/100mbps ethernet SNMP
2. Rack cabinet for server & switch no
3. Managed Switch, 18 channel 1Gbps no
4. System software : no
4.1. Software Controller CPU Single License no
4.2. Floating License Download, Engineering Software no
4.3. System Software (min. 512 Tag point) no
4.4. Alarm software module: alarm & event management system, based on no
OPC Alarm and Events (AE) specification, Open Database Connectivity with
MS SQL Server
4.5. SNMP connector software module: native Simple Network Management no
Protocol with Auto-discovery capability
4.6. License included : 1 client/ developer station for use as thick client desktop no
workstation or as thin client WebHMI developer, 1 WebHMI client, 5000
on-demand tags
4.7. Built in development package software to comply FDA CFR Part 11 no
4.8. WEB & Report Server, Environment & Energy Management System no
4.9. Runtime softwareSP1 Single license client station as thick client desktop no
workstation or as thin client for WebHMI
4.10. Audit TraiI License Software for configuration no
5. Historian software : no
5.1. Process Historian 2014 SP3 Basic Package, Runtime software, single license no
5.2. Historian Server no
6. Enclosure Panel no
6.1. Free Standing Outdo Panel Box, Powder Coating, RAL7035, Est. no
Dimension: 2100x800x600 , Thick: 2.0 mm
6.2. Fuse Protection Terminal Bloc for AI,AO,DI,DO no
6.3. Dell PC for client monitor no
6.4. Material Assembly : Terminal, Duct, Wiring Cable, Ferules no
6.5 UPS 3KvA no
6.6 Profinet Connector RJ45 no
6.7 Profinet Cable no
6.8 FO Box 6 port no
6.9 Pigtail Multimode FO SC no
6.10 Patch cord Multimode SC to SC no

B CONTROLLER, EXPANSION MODULE & ACCESSORIES


1. Industrial Grade Embedded PC, Integrated with 4x USB V3.0, 1x Serial no
(COM1); Watchdog, tempertaure and fan monitoring; RAID Controller
onboard; 15" touch (1280x800); with front USB Xeon 2.3 (3.3) Ghz, 8 MB
cache VT-D, AMT) 1 TB HDD SATA; DVD +/- RW 16
2. Expansion module, 32 channels digital outputs, transistor output 24VDC no
3. Expansion module, 32 channels digital input, 24VDC input no
4. Expansion module, 8 channels analog output, 0..10V/-10..+10V or no
0..20mA/4..20mA, A/D resolution 12 bits or 11 bits + sign
5. Expansion module, 8 channels analog input, 0..10V/-10..+10V or no
0..20mA/4..20mA, A/D resolution 12 bits or 11 bits + sign

To Collection Rp. -

TA2459 Lesaffre Garuda 70/75 23de-38a4-c013-c37e-2.13


Item BILL NO. 50
50.13 HVAC WORKS Qty. Unit Rate Rupiahs
No INSTANT DRY YEAST

TA2459 Lesaffre Garuda 71/75 23de-38a4-c013-c37e-2.13


Item BILL NO. 50
50.13 HVAC WORKS Qty. Unit Rate Rupiahs
No INSTANT DRY YEAST

50.13.5 HVAC CONTROL (Cont'd)


Supply and Install of HVAC Control complete with all necessary accessories in
accordance to the technical specification and drawings, as described : -

6. Communication processor minimum 4 port Real Time Switch no


7. Managed Layer 2 IE Switch no
8. Power supply 24VDC/10A, short circuit protection, DIN rail mounted no
9. Ethernet switch, 10/100Mbps 8 ports, DIN rail mounted no
10. Panel enclosure consist of circuit breakers, terminal blocks, fuses & no
accessories
11. HMI 15" Touch, comfort Panel no
12. Front Connector 40 Pole no
13. Mounting Rail 482 mm no

C SENSOR, TRANSMITTER & END DEVICES


1. Duct Humidity 0..100% RH accuracy ±3% & Temperature transmitter no
-50..50°C accuracy ±0.5°C, c/w factory certificate calibration
2. Differential Pressure Transmitter 0..5000Pa for air flow measurement, no
accuracy ±1.0Pa + ±1% of reading at 25°C, automatic zero point calibration,
including necessary averaging type air flow probe , c/w factory certificate
calibration
3. Differential Pressure Transmitter 0..2500Pa for air filter monitoring, accuracy no
±3.0Pa + ±1% of reading at 25°C, local display, automatic zero point
calibration, c/w factory certificate calibration
4. Room Differential Pressure Transmitter -100..+100Pa, accuracy ±0.5Pa + no
±1% of reading at 25°C, automatic zero point calibration, c/w factory certificate
calibration
5. SCR Controller 1phase 230V, 30A, Modbus RTU communication no
6. SCR Controller 3phase 380V, 35A, Modbus RTU communication no
7. SCR Controller 3phase 380V, 75A, Modbus RTU communication no
8. Air Flow Switch & temperature sensor for heater protection no
9. Panel enclosure for SCR Controller c/w ventilation fan, circuit breaker & no
accessories
10. Motorized Damper Actuator 5Nm modulating type, 24VDC power input no
11. Motorized Damper Actuator 10Nm on off type, 24VDC power input no
12. Duct static pressure transmitter 0..2kPa, accuracy ±3.0Pa + ±1% of no
reading at 25°C, c/w factory certificate calibration
13. Outside air Humidity 0..100% RH accuracy ±3% & Temperature no
transmitter -50..50°C accuracy ±0.5°C, c/w factory certificate calibration
14. Motorized Damper Actuator 5Nm on off type, 24VDC power input no

D INSTALLATION MATERIAL & LABOR


1. Cable ethernet UTP CAT6 for communication ls
2. Cable flexible multicore 0.75mm2 for digital IO points ls
3. Cable flexible multicore 0.75mm2 for actuator ls
4. Cable flexible multicore 0.75mm2 for analog IO points ls
5. Cable power HYY HY 1.5mm2 ls
6. Cable tray, PVC conduit & accessories ls

E ENGINEERING
1. Engineering cost for system development, testing & commissioning (PLC ls
Programming, HMI Programming) ls
2. FAT ls
3. Project documentation : drawing, SOP, etc ls
4. On Site Training (Operational, Maintenance, & Troubleshoot) ls

To Collection Rp. -

TA2459 Lesaffre Garuda 72/75 23de-38a4-c013-c37e-2.13


Item BILL NO. 50
50.13 HVAC WORKS Qty. Unit Rate Rupiahs
No INSTANT DRY YEAST

TA2459 Lesaffre Garuda 73/75 23de-38a4-c013-c37e-2.13


Item BILL NO. 50
50.13 HVAC WORKS Qty. Unit Rate Rupiahs
No INSTANT DRY YEAST

COLLECTIONS

Page 50.13 /1 -

Page 50.13 /2 -

Page 50.13 /3 -

Page 50.13 /4 -

Page 50.13 /5 -

Page 50.13 /6 -

Page 50.13 /7 -

Page 50.13 /8 -

Page 50.13 /9 -

50.13 HVAC WORKS


CARRIED TO SUMMARY AT END OF BILL NO. 50 Rp. -

TA2459 Lesaffre Garuda 74/75 23de-38a4-c013-c37e-2.13


Item BILL NO. 50
50.13 HVAC WORKS Qty. Unit Rate Rupiahs
No INSTANT DRY YEAST

TA2459 Lesaffre Garuda 75/75 23de-38a4-c013-c37e-2.13


BILL NO. 77
VINASSES STORAGE

TA2459 Lesaffre Garuda 1/28 0326-e734-24fb-16ca-Cover


Item BILL NO. 77 SUMMARY RUPIAHS
No. VINASSES STORAGE

SUMMARY

77.1 DEMOLITION N/A

77.2 EARTHWORK -

77.3 CONCRETE -

77.4 MASONRY -

77.5 METALS -

77.7 THERMAL AND MOISTURE PROTECTION -

77.8 DOORS AND WINDOWS -

77.9. FINISHES -

77.10 SPECIALITIES N/A

77.11 MECHANICAL WORKS -

77.2 ELECTRICAL WORKS -

77.3 HVAC WORKS -

BILL NO. 77
CARRIED TO SUMMARY -

TA2459 Lesaffre Garuda 2/28 0326-e734-24fb-16ca-Sum


Item BILL NO. 77 Qty Unit Rate Rupiahs
77.2 EARTHWORK
No. VINASSES STORAGE

77.2.1 CUT OFF PILE HEAD

Cut off pile head as drawings

A Spun pile, dia. 400mm nos

B Spun pile, dia. 800mm nos

77.2.2 EARTHWORK

Excavation, disposal and backfill in any material including rock or hard


material, working space at parimeter items as defined; Excavating, starting
from stripped level, trenches to receive depth as pecified (insite area)

C To Pile Cap m3

D To Slab Incl. Ramp m3

E To Tank Foundation m3

F To Wall m3

G To Tie Beam m3

77.2.3 BASE COURSES

Compacted of subgrade to 95% Standard Proctor Density as specified

H To Pile Cap m2

I To Slab Incl. Ramp m2

J To Tank Foundation m2

K To Tie Beam m2

Sandfill 100mm thick as specified

L To Pile Cap m2

M To Slab Incl. Ramp m2

N To Tank Foundation m2

O To Tie Beam m2

Compacted gravel 200m thick as specified

P To Under Ramp m2

TA2459 Lesaffre Garuda 3/28 0326-e734-24fb-16ca-2.2


Item BILL NO. 77 Qty Unit Rate Rupiahs
77.2 EARTHWORK
No. VINASSES STORAGE

To Collection Rp. -

77.2.4 TERMITE CONTROL

Termite control to soil; The protection against termites by spraying an


insecticide on the soil or on the fill before placing the vapor and after
building completed and importing landfill; undertaken by an approved
specialist; (5 years quarantee to be given) as specified.

A To Pile Cap m2

B To Slab Incl. Ramp m2

C To Tank Foundation m2

D To Wall m2

77.2.5 OTHERS

Plastic sheet

E To Pile Cap m2

F To Slab Incl. Ramp m2

G To Tank Foundation m2

H To Tie Beam m2

To Collection Rp. -

COLLECTIONS

Page 77.2 /1

Page 77.2 /2 -

TA2459 Lesaffre Garuda 4/28 0326-e734-24fb-16ca-2.2


Item BILL NO. 77 Qty Unit Rate Rupiahs
77.2 EARTHWORK
No. VINASSES STORAGE

77.2 EARTHWORK
CARRIED TO SUMMARY AT END OF BILL NO. 77 Rp. -

TA2459 Lesaffre Garuda 5/28 0326-e734-24fb-16ca-2.2


Item BILL NO. 77
77.3 CONCRETE Qty. Unit Rate Rupiahs
No. VINASSES STORAGE

77.3.1 FORMWORK

77.3.1.1 IN GROUND FORMWORK

The design, certification, construction and performance of the formwork,


falsework and backpropping shall be the responsibilty of Contractor.
Proposed method of installation and removal of formwork is to be
submitted to the Superintendent for comment prior to work being carried
out as per dwg note.
In ground formwork as follows; permanent formwork system for in-place
concrete, concrete hollow block 100mm thick, finish starting at/from any
level and including rebates or grooves formers as described to

A To Pile Cap m2 -

B To Slab Incl. Ramp m2 -

77.3.1.2 UPPER STRUCTURE FORMWORK

Smooth-Formed Finished concrete, plywood, metal, or other approved


panel materials, finish starting at/from any level and rebates or groove
formers as specified

C To Tank Foundation m2 -

D To Tie Beam and Beam m2 -

E To Wall m2 -

F To Column m2 -

77.3.2 CONCRETE

In-Situ Concrete

In-situ concrete designed mix Grade 30 Mpa, (K-350) NFA; ± 20mm


aggregate, vibrated with standard flatness as described ;

G To Pile Cap m3 -

H To Slab Incl. Ramp m3 -

I To Tank Foundation m3 -

J To Tie Beam and Beam m3 -

K To Wall m3 -

L To Column m3 -

Lean Concrete

Plain in-situ concrete, designed mix grade f'c= Mpa,(K-125), 40mm


aggregate, 50mm thick as described,

M To Pile Cap m2 -

N To Slab on Ground m2 -

TA2459 Lesaffre Garuda 6/28 0326-e734-24fb-16ca-2.3


Item BILL NO. 77
77.3 CONCRETE Qty. Unit Rate Rupiahs
No. VINASSES STORAGE

To Collection Rp. -

77.3.2 CONCRETE, CONT'D

Lean Concrete

Plain in-situ concrete, designed mix grade f'c= Mpa,(K-125), 40mm


aggregate, 50mm thick as described,

A To Tank Foundation m2 -

B To Tie Beam m2 -

77.3.3 REINFORCEMENT

Manufacture reinforcement bars is according to "Manual of Standard


Practice" CRSI's as follows; supply, cleaned, measurement, positioning,
setting and install. Reinforcement measure include joint dowel bars,
bolsters, chairs, spacers and other device for spacing, supporting and
fastening reinforcing bars and welded wire reinforcement in place.

Reinforcing bars is Grade 60/420 deformed or Grade BJTD 40 deformed.


round mild steel, as described in

C Dia. 19mm, To Pile Cap kg -

D Dia. 13mm, To Pile Cap kg -

E Dia. 13mm, To Slab Incl. Ramp kg -

F Dia. 22mm, To Tank Foundation kg -

G Dia. 16mm, To Tank Foundation kg -

H Dia. 13mm, To Tank Foundation kg -

I Dia. 10mm, To Tank Foundation kg -

J Dia. 22mm, To Tie Beam and Beam kg -

K Dia. 19mm, To Tie Beam and Beam kg -

L Dia. 10mm, To Tie Beam and Beam kg -

M Dia. 16mm, To Column kg -

N Dia. 10mm, To Column kg -

O Dia. 10mm, To Wall kg -

77.3.4 OTHERS

P Supply and install waterstop, steel plate 300x3mm complete with all m -
necessary per drawings and specifications

Q Supply and install slab connection, dowel rebar dia. 16mm (round bar) ctc m -
300, L=300mm, bitumen paint complete with galv. Steel angle and anchor
bolt per drawings and specifications

TA2459 Lesaffre Garuda 7/28 0326-e734-24fb-16ca-2.3


Item BILL NO. 77
77.3 CONCRETE Qty. Unit Rate Rupiahs
No. VINASSES STORAGE

To Collection Rp. -

COLLECTIONS

Page 31.3 /1 -

Page 31.3 /2 -

TA2459 Lesaffre Garuda 8/28 0326-e734-24fb-16ca-2.3


Item BILL NO. 77
77.3 CONCRETE Qty. Unit Rate Rupiahs
No. VINASSES STORAGE

77.3 CONCRETE
CARRIED TO SUMMARY AT END OF BILL NO. 77 Rp. -

TA2459 Lesaffre Garuda 9/28 0326-e734-24fb-16ca-2.3


Item BILL NO. 77
77.4 MASONRY Qty. Unit Rate Rupiahs
No VINASSES STORAGE

77.4.1 UNIT MASONRY

Supply and Install Autoclaved aerated concrete block wall with mortar;
including reinforced concrete bonding ties, anchorage, latching, stiffener
columns and lintels beams as required, all in accordancce with drawings
and specifications
A To Wall 150mm thick External Wall m2 -

B To Wall 150mm thick Internal Wall m2 -

77.4.2 PLASTERED

Plaster; Mortar instant trowelled smooth with and including cement coating
instant as described

C To Wall 150mm thick m2 -

77.4.3 WALL PARTITION


Supply and Install Metal cladding Trimdek 0.45 BMT finish colorbond
with transparent cladding fixed to steel structure, including sealant, and all
necessary fixing accessories; all in accordance with drawings and
specifications
D To Wall m2 -

Supply and install mineral wool, in accordance with manufacturer's


recommendations, as specified

E To Wall m2 -

Supply and install gypsum board including frames, support and all
necessary in accordance with manufacturer's recommendations, as specified

F To Wall m2 -

77.4.3 CEILING PARTITION

Supply and install calsium silicate board 6mm glued in gypsum ceiling
including ceiling suspension system and fixing accessories all in
accordance with drawings and specifications

G To Ceiling m2 -

Supply and Install Grid system with accoustic tile complete with metal stud
framing hanger and all necessary accessories and support; all in
accordancce with drawings and specifications

H To Ceiling m2 -

77.4 MASONRY
CARRIED TO SUMMARY AT END OF BILL NO. 77 Rp. -

TA2459 Lesaffre Garuda 10/28 0326-e734-24fb-16ca-2.4


Item BILL NO. 77
77.4 MASONRY Qty. Unit Rate Rupiahs
No VINASSES STORAGE

TA2459 Lesaffre Garuda 11/28 0326-e734-24fb-16ca-2.4


Item BILL NO. 77 77.5 METALS
Qty. Unit Rate Rupiahs
No VINASSES STORAGE

77.5.1 STRUCTURAL FRAMING

The following in steel structure in framing sanblasting and painting


finished ; from ground level to roof floor level; comprising wide flange
bolted to mild steel, cleats, welded to rafter; including all labour,
materials and plant in fabricating,erecting with welded and bolted shop
and site connections; assembling and erecting with welded and bolted
shop and site connections; and all necessaries as specified on
specification and drawing; steel grade as note on specifications ( ASTM
A-36 / BJ 37 for steel structure)
A SC6, WF250x250x9x14 kg -

B PR3, C150x65x20x2.3 kg -

C HB17, Dia16-HB kg -

D PR5A, C200x75x20x2.5 kg -

E R1, WF150x75x5x7-R kg -

F R3, WF250x125x6x9-R kg -

G R5, WF350x175x7x11-R kg -

H SB1, WF150x75x5x7-SB kg -

I SB21A, C150x65x20x2.3-SB kg -

J TR2, Dia12-TR kg -

K SB21C, C200x75x20x2.3-SB kg -

L SG2, WF200x100x5.5x8-SG kg -

M SG3, WF250x125x6x9-SG kg -

N SG9, WF600x200x11x17-SG kg -

O All connecting plates, brackets, cleats, bolts, anchor bolts and stiffeners, Ls -
welding, including sandblasting and painted finish and all necessary
fixing accessories as described

77.5 METALS

TA2459 Lesaffre Garuda 12/28 0326-e734-24fb-16ca-2.5


Item BILL NO. 77 77.5 METALS
Qty. Unit Rate Rupiahs
No VINASSES STORAGE

CARRIED TO SUMMARY AT END OF BILL NO. 77 Rp. -

TA2459 Lesaffre Garuda 13/28 0326-e734-24fb-16ca-2.5


Item BILL NO. 77 77.7 THERMAL AND MOISTURE Qty Unit Rate Rupiahs
No. VINASSES STORAGE PROTECTION

77.7.1 FLASHING AND SHEET METAL

Supply and Install metal roof Klip Lok Optima 0.45 BMT fixed to steel
purlin including flashing, sealant, and all fixing accessories; all in
accordance with drawings and specifications

A To Roof and Canopy m2 -

Supply and Install Waterstop Colorbond finish fixed to metal roof sheet,
including sealant and all necessary fixing accessories; all in accordance with
drawings and specifications

B To Roof m -

Supply and Install Metal cladding Trimdek 0.45 BMT finish colorbond
fixed to steel structure, including sealant, over flow galvanized steel pipe
Ø2" 6000mm CTC, and all necessary fixing accessories; all in accordance
with drawings and specifications

C To Fascia m2 -

Supply and Install Metal Flashing 0.45 BMT finish colorbond fixed to steel
purlin, including sealant and all necessary fixing accessories; all in
accordance with drawings and specifications

D To Roof m -

77.7.2 ROOF SPECIALITIES

Supply and Install metal gutter 0.5mm with weatherproof sealant complete
with plate support, jointing and all necessary fixing accessories and support,
in accordance with manufacturer's recommendations, as drawings and
specifications

E To Roof Gutter m2 -

Supply and Install down pipe complete with overflow, steel clamp, support,
fitting, bracket, steel unp, and all fixing accessories; all in accordance with
drawings and specifications

F PVC Downpipe Ø4" m -

G Chromium roof drain strainer nos -

Supply and install roof insulation, rockwool 60kg/m3 50mm+double sided


flame stop 506 aluminium foil with wiremesh galv. M2 50x50, including all
support and necessary per drawings and specifications

H To Roof m2 -

77.7 THERMAL AND MOISTURE PROTECTION


CARRIED TO SUMMARY AT END OF BILL NO. 77 Rp. -

TA2459 Lesaffre Garuda 14/28 0326-e734-24fb-16ca-2.7


Item BILL NO. 77 77.7 THERMAL AND MOISTURE Qty Unit Rate Rupiahs
No. VINASSES STORAGE PROTECTION

TA2459 Lesaffre Garuda 15/28 0326-e734-24fb-16ca-2.7


Item BILL NO. 77
77.8 DOORS AND WINDOWS Qty. Unit Rate Rupiahs
No. VINASSES STORAGE

77.8.1 DOORS

Supply and install high speed doors including frames, hardwares, treshold,
steel plate, and all necessary accessories and fixing supports as drawings
and specifications

A 77.DA.001 nos -

Supply and install sectional doors including dock shelter, frames,


hardwares, treshold, steel plate, and all necessary accessories and fixing
supports as drawings and specifications

B 77.DB.002 nos -

C 77.DB.003 nos -

Supply and install steel doors including frames, hardwares, treshold, steel
plate, and all necessary accessories and fixing supports as drawings and
specifications

D 77.DL.004 nos -

E 77.DL.005 nos -

F 77.DL.008 nos -

Supply and install steel door including vision panel / louvre, frames,
hardwares, treshold, steel plate, and all fixing accessories and supports as
drawings and specifications

G 77.DL.006 nos -

H 77.DL.007 nos -

77.8.2 WINDOWS

Supply and install aluminium fix window complete with laminated


tempered glass + clear glass, hardwares, and all necessary components,
fixing, accessories as drawing and specification.

I 77.WA.001 nos -

J 77.WA.002 nos -

Supply and install aluminium openable window complete with laminated


tempered glass + clear glass, hardwares, and all necessary components,
fixing, accessories as drawing and specification.

K 77.WB.003 nos -

77.8.3 LOUVRES

Supply and install steel louvre complete with removable insect screen,
hardwares, and all necessary components, fixing, accessories as drawing
and specification.

L 77.LA.001 nos -

M 77.LA.002 nos -

TA2459 Lesaffre Garuda 16/28 0326-e734-24fb-16ca-2.8


Item BILL NO. 77
77.8 DOORS AND WINDOWS Qty. Unit Rate Rupiahs
No. VINASSES STORAGE
To Collection Rp. -

77.8.3 LOUVRES, CONT'D

Supply and install steel louvre complete with removable insect screen,
hardwares, and all necessary components, fixing, accessories as drawing
and specification.

A 77.LA.003 nos -

B 77.LA.004 nos -

C 77.LA.005 nos -

D 77.LA.006 nos -

E 77.LA.007 nos -

F 77.LA.008 nos -

G 77.LA.009 nos -

H 77.LA.010 nos -

I 77.LA.011 nos -

J 77.LA.012 nos -

K 77.LA.013 nos -

L 77.LA.014 nos -

L 77.LA.015 nos -

M 77.LA.016 nos -

O 77.LA.017 nos -

P 77.LA.018 nos -

Q 77.LA.019 nos -

To Collection Rp. -

COLLECTIONS

Page 77.8 /1 -

Page 77.8 /2 -

TA2459 Lesaffre Garuda 17/28 0326-e734-24fb-16ca-2.8


Item BILL NO. 77
77.8 DOORS AND WINDOWS Qty. Unit Rate Rupiahs
No. VINASSES STORAGE

77.8 DOORS AND WINDOWS


CARRIED TO SUMMARY AT END OF BILL NO. 77 Rp. -

TA2459 Lesaffre Garuda 18/28 0326-e734-24fb-16ca-2.8


Item BILL NO. 77
77.9. FINISHES Qty. Unit Rate Rupiahs
No VINASSES STORAGE

77.9.1 FLOOR FINISHES

Prepare and apply epoxy quartz; all in accordance with manufacturer's


instruction, drawings, and specifications

A To Floor m2 -

Supply and install Homogenous Tile complete with screed, gape grouting
and all in accordance with manufactured instruction applied: all in
accordance with drawings and specifications

B To Floor m2 -

C To Skirting m -

77.9.2 WALL FINISHES

Prepare smooth and apply waterbased acrylic emulsion paint finish, in


accordance with manufacturer's recommendations, as specified to face of :

D Applied to plastered autoclaved concrete walls (Internal Wall) m2 -

E Applied to gypsum board (Internal Wall) m2 -

Prepare smooth and apply waterbased wethershield emulsion paint finish,


in accordance with manufacturer's recommendations, as specified to face of

F Applied to plastered autoclaved concrete walls (External Wall) m2 -

77.9.3 CEILING FINISHES

Prepare smooth and apply waterbased acrylic emulsion paint finish, in


accordance with manufacturer's recommendations, as specified to face of :

G To Calciboard Ceiling m2 -

77.9. FINISHES
CARRIED TO SUMMARY AT END OF BILL NO. 77 Rp. -

TA2459 Lesaffre Garuda 19/28 0326-e734-24fb-16ca-2.9


Item BILL NO. 77
77.10 SPECIALITIES Qty. Unit Rate Rupiahs
No VINASSES STORAGE

77.10 SPECIALITIES
CARRIED TO SUMMARY AT END OF BILL NO. 77 Rp. N/A

TA2459 Lesaffre Garuda 20/28 0326-e734-24fb-16ca-2.10


Item BILL NO. 77
77.11 MECHANICAL WORKS Qty. Unit Rate Rupiahs
No VINASSES STORAGE

77.11 MECHANICAL WORKS

77.11.1 HYDRANT & SPRINKLER SYSTEM

HYDRANT SYSTEM INSTALLATION


Supply and install Hydrant pipes, Black steel pipe to ASTM A 53 schedule 40 ,
Grade B, including fitting (for 50 mm dia. Pipe or less) fixed in position complete
with supports, hangers, brackets, clamp, painting, and other necessary fixing and
jointing material in accordance to the technical specification and drawings, as
described;

PIPEWORKS

A 80mm diameter pipe m

FITTINGS

B Fitting 80mm diameter no

VALVE AND ANCILLARIES

C Portable fire extinguisher with capacity 6 kg chemical powder ABC type. no

D Indoor Hydrant Box (IHB) complete with hose rack, rubber hose, hose reel, valve no
and nozzle

To Collection Rp. -

TA2459 Lesaffre Garuda 21/28 0326-e734-24fb-16ca-2.11


Item BILL NO. 77
77.11 MECHANICAL WORKS Qty. Unit Rate Rupiahs
No VINASSES STORAGE

SPRINKLER SYSTEM INSTALLATION


Supply and install Sprinkler pipes, Black steel pipe to ASTM A 53 schedule 40 ,
Grade B, including fitting (for 50 mm dia. Pipe or less) fixed in position complete
with supports, hangers, brackets, clamp, painting, and other necessary fixing and
jointing material in accordance to the technical specification and drawings, as
described;

PIPEWORKS

H 25mm diameter pipe m

I 32mm diameter pipe m

J 40mm diameter pipe m

K 50mm diameter pipe m

L 65mm diameter pipe m

M 80mm diameter pipe m

N 100mm diameter pipe m

O 150mm diameter pipe m

P 200mm diameter pipe m

FITTINGS

Q Fitting 65mm diameter no

To Collection Rp. -

TA2459 Lesaffre Garuda 22/28 0326-e734-24fb-16ca-2.11


Item BILL NO. 77
77.11 MECHANICAL WORKS Qty. Unit Rate Rupiahs
No VINASSES STORAGE

SPRINKLER SYSTEM INSTALLATION (Cont'd)


Supply and install Sprinkler pipes, Black steel pipe to ASTM A 53 schedule 40 ,
Grade B, including fitting (for 50 mm dia. Pipe or less) fixed in position complete
with supports, hangers, brackets, clamp, painting, and other necessary fixing and
jointing material in accordance to the technical specification and drawings, as
described;

FITTINGS

A Fitting 80mm diameter no

B Fitting 100mm diameter no

C Fitting 150mm diameter no

D Fitting 200mm diameter no

VALVE AND ANCILLARIES

E Head sprinkler pendant type no

F Head sprinkler upright type no

G Main Control Valve (MCV); 200mm diameter set

H Branch Control Valve (BCV); 150mm diameter set

H Alarm Control Valve (ACV); 150mm diameter set

I AAV; 25mm diameter no

J Test Drain; 25 mm diameter set

K Flexible coupling; 150mm diameter no

To Collection Rp. -

COLLECTION

Page 77.11 /1 -

Page 77.11 /2 -

Page 77.11 /3 -

77.11 MECHANICAL WORKS


CARRIED TO SUMMARY AT END OF BILL NO. 77 Rp. -

TA2459 Lesaffre Garuda 23/28 0326-e734-24fb-16ca-2.11


Item BILL NO. 77
77.2 ELECTRICAL WORKS Qty. Unit Rate Rupiahs
No VINASSES STORAGE

77.12 ELECTRICAL WORKS

77.12.1 SUB DISTRIBUTION BOARDS


Supply, Install and Testing Commissioning the following Sub Distribution board
fix in position includes circuit breaker, board, busbar, digital multimeter,
contactor, surge arrester, potensial transformer, current transformer, indicator
lamp, fuse, loto, star / stop push button, and all necessary accessories in
arcondance to the technical spesification as shown on drawing, as described : -

A 77DB01 no

77.12.2 MAIN AND SUB-MAINS CABLES


Supply and Install the following Main and Sub-Mains circuit distribution cable
run & fixed on cable tray/ladders including all necessary accessories in
arcondance to the technical spesification as shown on drawing, as described : -

B From SDB…. to 77DB01 m by other package

77.12.3 LIGHTING FIXTURES & POWER OUTLET


Supply and Install the following light fittings including tubes or lamps fixed in
position complete with all accessories and support in accordance with the
technical specification and drawings, as described :-

C High bay LED 75W, 10503 lm no

D High bay LED 75W, 10503 lm, c/w nicad battery duration 1 hour no

E Recessed mounted TLED 40W, 220V, 3709 lm no

F Recessed mounted TLED 40W, 220V, 3709 lm, c/w nicad battery duration 1 no
hour

G Exit sign LED 5W, 220V, wall mounted no

H Waterproof LED 20W, 220V, IP65, 2000 lm, L600 no

I Waterproof LED 20W, 220V, IP65, 2000 lm, L600, c/w nicad battery duration 1 no
hour

J Flood light LED 100W, 9500 lm no

Supply and Install the following switches including provision of steel/metal box
and all accessories accordance with the technical specification and drawings, as
described :-

K Single gang, 1 way switch, 10A no

L Double gang, 1 way switch, 10A no

Supply and Install lighting & switch cables from sub circuit to final circuit
including grounding system and all neccessary accessories accordance with the
technical specification and drawings, as described :-

M Cabling point from local panel (500V/CU/PVC 3C x 2.5 mm² shall be UV & no
chemical resistance) run-in and with PVC high impact conduit) to; lighting and
switch

To Collection Rp. -

TA2459 Lesaffre Garuda 24/28 0326-e734-24fb-16ca-2.12


Item BILL NO. 77
77.2 ELECTRICAL WORKS Qty. Unit Rate Rupiahs
No VINASSES STORAGE

POWER OUTLET
Supply and Install the following power outlet including provision of steel/metal
box and all accessories accordance with the Technical Specification and
drawings, as described :-

A General socket outlet, wall mounted, 16A, 250V, single gang no

B General socket outlet, wall mounted, 16A, 250V, double gang no

C General socket outlet c/w cover, wall mounted, 16A, 250V, (waterproof) single no
gang

77.12.4 TRAYS AND LADDERS


Supply and Install hot dip galvanized tray and ladder 2mm thickness include
jointing, elbow, tee, fixing accessories and hangers and all necessary accessories
accordance with the technical specification and drawings, as described :-

Electrical
D Cable tray 300x100mm m

Electronic
E Cable tray 200x100mm m

77.12.5 GROUNDING & LIGHTNING PROTECTION SYSTEM


Supply and Install Grounding system for panel and equipment complete with
support and all neccessary accessories accordance with the technical
specification and drawings, as described :-

F Earth pit, Conductor clamp and rod electrode, dia 19mm x 3000 length no

G Earthing bonding bar (copper bar) 50x3mm thk, c/w isolator no

H BC 70mm2, grounding cable for main/mesh earthing c/w connector and m


grounding lug

I Potential earth clamp (100kA) no

J Bonding cable NYAF 35mm2 m

77.12.6 FIRE ALARM


Supply and Install the following Fire Alarm Equipment complete with support, and
all necessary accessories in accordance to the technical specification and
drawings, as described : -

K JBFA-77-01 no

L Addressable photoelectric smoke detector no

M Addressable manual call point no

N Horn & strobe light no

O Beam detedtor receiver no

P End of line (EOL) no

To Collection Rp. -

TA2459 Lesaffre Garuda 25/28 0326-e734-24fb-16ca-2.12


Item BILL NO. 77
77.2 ELECTRICAL WORKS Qty. Unit Rate Rupiahs
No VINASSES STORAGE

77.12.6 FIRE ALARM Cont'd)


Supply and Install the following Fire Alarm cables in final sub-circuit to
termination, run-in and with steel conduit 20mm dia; including earthing system
and all necessary accessories in accordance to the technical spesification as
shown on drawing, as described : -

A Power Cable FRC 2Cx2,5 mm2; from control room BD50 m

B Cable FRC STP 2Cx1,5 mm2; for detector point no

C Cable FRC STP 2Cx1,5 mm2; for manual call point no

D Cable FRC 2Cx1,5 mm2; for horn & strobe light point no

77.12.7 PUBLIC ADDRESS


Supply and Install the following Sound System Equipment complete with support,
and all necessary accessories in accordance to the technical specification and
drawings, as described : -

E Wall mounted switch rack JBPA-77-01 (SR-77-01) no

F Indoor ceiling mounted speaker 6W no

G Horn speaker 15W no

Supply and Install the following Public Address cables in final sub-circuit to
termination, run-in and with steel conduit 20mm dia; including earthing system
and all necessary accessories in accordance to the technical spesification as
shown on drawing, as described : -

H Cable FO OM3; from BD96 m

I Cable NYMHY 2Cx1,5 mm2; for indor ceiling speaker point no

J Cable NYMHY 2Cx1,5 mm2; for horn speaker point no

77.12.8 DATA AND TELEPHONE


Supply and Install the following Data and Communication System
Equipment complete with support, and all necessary accessories in
accordance to the technical specification and drawings, as described : -

K Wall mounted switch rack SR-50-01 no

L Single gang type data outlet (RJ45) no

M Single gang type telephone outlet (RJ45) no

Supply and Install the following Data and Telephone cables in final sub-circuit
to termination, run-in and with steel conduit 20mm dia; including earthing system
and all necessary accessories in accordance to the technical spesification as
shown on drawing, as described : -

M Cable UTP-CAT6/FO mm2; for data outlet point no

N Cable UTP-CAT6/FO mm2; for data outlet point no

To Collection Rp. -

TA2459 Lesaffre Garuda 26/28 0326-e734-24fb-16ca-2.12


Item BILL NO. 77
77.2 ELECTRICAL WORKS Qty. Unit Rate Rupiahs
No VINASSES STORAGE

77.12.8 DATA AND TELEPHONE (Cont'd)


Supply and Install the following Data and Telephone cables in final sub-circuit
to termination, run-in and with steel conduit 20mm dia; including earthing system
and all necessary accessories in accordance to the technical spesification as
shown on drawing, as described : -

A Cable UTP-CAT6/FO mm2; for telephone outlet point no

B Cable FO OM3; from BD96 m

77.12.9 SECURITY SYSTEM


Supply and Install the following Security System Equipment complete with
support, and all necessary accessories in accordance to the technical specification
and drawings, as described : -

C Wall mounted switch rack SR-50-01 no

D IP based bullet fix camera indoor type no

E IP based bullet fix camera outdoor type no

F Acces control door consist of; no


Door control
Finger print / card reader
Push button door release

Supply and Install the following Security cables in final sub-circuit to


termination, run-in and with PVC conduit 25mm dia underground direct burried
min 500mm below grade or through pipe rack; including earthing system and all
necessary accessories in accordance to the technical spesification as shown on
drawing, as described : -

G Cable UTP-CAT6/FO; for bullet fix camera indoor type point no

H Cable UTP-CAT6/FO; for bullet fix camera outdoor type point no

I Cable UTP-CAT6/FO; for acces control door point no

To Collection Rp. -

COLLECTIONS

Page 77.12 /1 -

Page 77.12 /2 -

Page 77.12 /3 -

Page 77.12 /4 -

77.2 ELECTRICAL WORKS


CARRIED TO SUMMARY AT END OF BILL NO. 77 Rp. -

TA2459 Lesaffre Garuda 27/28 0326-e734-24fb-16ca-2.12


Item BILL NO. 77
77.3 HVAC WORKS Qty. Unit Rate Rupiahs
No VINASSES STORAGE

77.13 HVAC WORKS

77.13.1 EQUIPMENT

DX UNIT
Supply and Install of DX Units complete with hangers/supports, vibration
mountings, neoprene pads and all necessary accessories in accordance to
the technical specification and drawings, as described : -

A IU-DX.77.00.01; wall mounted, cooling capacity 5.2kWth, supply no


air flow 858 CMH, 0.1kW, 220V/1Ph/50Hz

B OU-DX.77.00.01; air colled inverter, cooling capacity 5.2kWth, supply no


air flow 564 CMH, 2.2kW, 220V/1Ph/50Hz

77.13.2 REFRIGERANT & DRAIN PIPES


Supply and install the following Refrigerant Copper Pipeworks including
FM Approved insulation ,vapour barrier, trap, fittings (for 50mm diameter
pipe or less), joints, flanges, support and all accessories in accordance to
the technical specification and drawings, as described : -

C 6.5 mm diameter pipe copper c/w insulation m

D 9,5 mm diameter pipe copper c/w insulation m

E 12,7 mm diameter pipe copper c/w insulation m

DRAIN PIPES
F 25 mm diameter pipe PVC Class AW c/w insulation m

77.3 HVAC WORKS


CARRIED TO SUMMARY AT END OF BILL NO. 77 Rp. -

TA2459 Lesaffre Garuda 28/28 0326-e734-24fb-16ca-2.13


BILL NO. 92
MAINTENANCE AND UTILITIES

TA2459 Lesaffre Garuda 1/45 7046-92f7-20b4-d4c3-Cover


Item BILL NO. 92 SUMMARY RUPIAHS
No. MAINTENANCE AND UTILITIES

SUMMARY

92.1 DEMOLITION N/A

92.2 EARTHWORK -

92.3 CONCRETE -

92.4 MASONRY -

92.5 METALS -

92.7 THERMAL AND MOISTURE PROTECTION -

92.8 DOORS AND WINDOWS -

92.9. FINISHES -

92.10 SPECIALITIES -

92.11 MECHANICAL WORKS -

92.12 ELECTRICAL WORKS -

92.13 HVAC WORKS -

BILL NO. 92
CARRIED TO SUMMARY -

TA2459 Lesaffre Garuda 2/45 7046-92f7-20b4-d4c3-Sum


Item BILL NO. 92 Qty Unit Rate Rupiahs
92.2 EARTHWORK
No. MAINTENANCE AND UTILITIES

92.2.1 CUT OFF PILE HEAD

Cut off pile head as drawings

A Spun pile, dia. 400mm nos

92.2.2 EARTHWORK

Excavation, disposal and backfill in any material including rock or hard


material, working space at parimeter items as defined; Excavating, starting
from stripped level, trenches to receive depth as pecified (insite area)

B To Pile Caps m3

C To Slab incl. ramp m3

D To Tie Beam m3

E To Pedestal m3

F To Plinths/Tank Foundation m3

92.2.3 BASE COURSES

Compacted of subgrade to 95% Standard Proctor Density as specified

G To Pile Caps m2

H To Slab incl. ramp m2

I To Tie Beam m2

J To Plinths/Tank Foundation m2

Sandfill 100mm thick as specified

K To Pile Caps m2

L To Slab m2

M To Tie Beam m2

N To Plinths/Tank Foundation m2

Compacted gravel 200mm thick as specified

O To Under Ramp m2

92.2.4 TERMITE CONTROL

Termite control to soil; The protection against termites by spraying an


insecticide on the soil or on the fill before placing the vapor and after
building completed and importing landfill; undertaken by an approved
specialist; (5 years quarantee to be given) as specified.

P To Pile Caps m2

Q To Slab incl. ramp m2

TA2459 Lesaffre Garuda 3/45 7046-92f7-20b4-d4c3-2.2


Item BILL NO. 92 Qty Unit Rate Rupiahs
92.2 EARTHWORK
No. MAINTENANCE AND UTILITIES

To Collection Rp. -

92.2.4 TERMITE CONTROL, CONT'D

Termite control to soil; The protection against termites by spraying an


insecticide on the soil or on the fill before placing the vapor and after
building completed and importing landfill; undertaken by an approved
specialist; (5 years quarantee to be given) as specified.

A To Tie Beam m2

B To Pedestal m2

C To Plinths/Tank Foundation m2

92.2.5 OTHERS

Plastic sheet

D To Pile Caps m2

E To Perimeter Slab m2

F To Tie Beam m2

G To Plinths/Tank Foundation m2

To Collection Rp. -

COLLECTIONS

Page 92.2/1 -

Page 92.2/2 -

TA2459 Lesaffre Garuda 4/45 7046-92f7-20b4-d4c3-2.2


Item BILL NO. 92 Qty Unit Rate Rupiahs
92.2 EARTHWORK
No. MAINTENANCE AND UTILITIES

92.2 EARTHWORK
CARRIED TO SUMMARY AT END OF BILL NO. 92 Rp. -

TA2459 Lesaffre Garuda 5/45 7046-92f7-20b4-d4c3-2.2


Item BILL NO. 92
92.3 CONCRETE Qty. Unit Rate Rupiahs
No. MAINTENANCE AND UTILITIES

92.3.1 FORMWORK

92.3.1.1 IN GROUND FORMWORK

The design, certification, construction and performance of the formwork,


falsework and backpropping shall be the responsibilty of Contractor.
Proposed method of installation and removal of formwork is to be
submitted to the Superintendent for comment prior to work being carried
out as per dwg note.
In ground formwork as follows; permanent formwork system for in-place
concrete, concrete hollow block 100mm thick, finish starting at/from any
level and including rebates or grooves formers as described to

A To Pile Caps m2 -

B To Slab Incl. Ramp m2 -

C To Tie Beam m2 -

92.3.1.2 UPPER STRUCTURE FORMWORK

Smooth-Formed Finished concrete, plywood, metal, or other approved


panel materials, finish starting at/from any level and rebates or groove
formers as specified

D To Upper Slab m2 -

E To Pedestal and Column m2 -

F To Gutter m2 -

G To Plinths m2 -

Bondex BMT 0.7 thick including shear connector, support and all
necessary as drawing specified

H To Floor m2 -

92.3.2 CONCRETE

In-Situ Concrete

In-situ concrete designed mix Grade 30 Mpa, (K-350) NFA; ± 20mm


aggregate, vibrated with standard flatness as described ;

I To Pile Caps m3 -

J To Ground and Upper Slab Incl. Ramp m3 -

K To Tie Beam and Upper Beam m3 -

L To Pedestal and Column m3 -

M To Plinths m3 -

TA2459 Lesaffre Garuda 6/45 7046-92f7-20b4-d4c3-2.3


Item BILL NO. 92
92.3 CONCRETE Qty. Unit Rate Rupiahs
No. MAINTENANCE AND UTILITIES

To Collection Rp. -

92.3.2 CONCRETE, CONT'D

Lean Concrete

Plain in-situ concrete, designed mix grade f'c= Mpa,(K-125), 40mm


aggregate, 50mm thick as described,

A To Pile Caps m2 -

B To Slab Incl. Ramp m2 -

C To Tie Beam m2 -

E To Plinths/Tank Foundation m2 -

92.3.3 REINFORCEMENT

Manufacture reinforcement bars is according to "Manual of Standard


Practice" CRSI's as follows; supply, cleaned, measurement, positioning,
setting and install. Reinforcement measure include joint dowel bars,
bolsters, chairs, spacers and other device for spacing, supporting and
fastening reinforcing bars and welded wire reinforcement in place.

Wiremesh as specified

F To Slab M10-150 1 layer m2 -

G To Slab M12-150 1 layer m2 -

Reinforcing bars is Grade 60/420 deformed or Grade BJTD 40 deformed.


round mild steel, as described in

H Dia. 19mm, To Pile Caps kg -

I Dia. 19mm, To Pile Caps kg -

J Dia. 16mm To Slab Incl. Ramp kg -

K Dia. 13mm To Slab Incl. Ramp kg -

L Dia. 10mm To Slab Incl. Ramp kg -

M Dia. 22mm, To Tie Beam kg -

N Dia. 19mm, To Tie Beam kg -

O Dia. 10mm, To Tie Beam kg -

P Dia. 16mm, To Pedestal kg -

Q Dia. 10mm, To Pedestal kg -

92.3.4 SUNDRIES

R Supply and installpolystirene 5mm thick replace by flexible joint filler m


complete with all necessary per drawings and specifications

S Chemical anchor nos

TA2459 Lesaffre Garuda 7/45 7046-92f7-20b4-d4c3-2.3


Item BILL NO. 92
92.3 CONCRETE Qty. Unit Rate Rupiahs
No. MAINTENANCE AND UTILITIES

To Collection Rp. -

COLLECTIONS

Page 92.3 /1 -

Page 92.3 /2 -

TA2459 Lesaffre Garuda 8/45 7046-92f7-20b4-d4c3-2.3


Item BILL NO. 92
92.3 CONCRETE Qty. Unit Rate Rupiahs
No. MAINTENANCE AND UTILITIES

92.3 CONCRETE
CARRIED TO SUMMARY AT END OF BILL NO. 92 Rp. -

TA2459 Lesaffre Garuda 9/45 7046-92f7-20b4-d4c3-2.3


Item BILL NO. 92
92.4 MASONRY Qty. Unit Rate Rupiahs
No MAINTENANCE AND UTILITIES

92.4.1 UNIT MASONRY

Supply and Install Autoclaved aerated concrete block wall with mortar;
including reinforced concrete bonding ties, anchorage, latching, stiffener
columns and lintels beams as required, all in accordancce with drawings
and specifications
A To Wall 150mm thick External Wall m2 -

B To Wall 150mm thick Internal Wall m2 -

92.4.2 PLASTERED

Plaster; Mortar instant trowelled smooth with and including cement coating
instant as described

C To Wall 150mm thick m2 -

92.4.3 WALL PARTITION


Supply and Install Metal cladding Trimdek 0.45 BMT finish colorbond
with transparent cladding fixed to steel structure, including sealant, and all
necessary fixing accessories; all in accordance with drawings and
specifications
D To Wall m2 -

92.4.3 CEILING PARTITION

Supply and install calsium silicate board 6mm glued in gypsum ceiling
including ceiling suspension system and fixing accessories all in
accordance with drawings and specifications

E To Ceiling m2 -

Supply and Install Grid system with accoustic tile complete with metal stud
framing hanger and all necessary accessories and support; all in
accordancce with drawings and specifications

F To Ceiling m2 -

92.4 MASONRY
CARRIED TO SUMMARY AT END OF BILL NO. 92 Rp. -

TA2459 Lesaffre Garuda 10/45 7046-92f7-20b4-d4c3-2.4


Item BILL NO. 92 92.5 METALS
Qty. Unit Rate Rupiahs
No MAINTENANCE AND UTILITIES

92.5.1 STRUCTURAL FRAMING

The following in steel structure in framing sanblasting and painting


finished ; from ground level to roof floor level; comprising wide flange
bolted to mild steel, cleats, welded to rafter; including all labour,
materials and plant in fabricating,erecting with welded and bolted shop
and site connections; assembling and erecting with welded and bolted
shop and site connections; and all necessaries as specified on
specification and drawing; steel grade as note on specifications ( ASTM
A-36 / BJ 37 for steel structure)
A SC3, WF200x100x5.5x8 kg -

B SC8, WF300x300x10x15 kg -

C GH20A, CAST. 675x200x9x14 kg -

D HB17, Dia16-HB kg -

E PR3, C150x65x20x2.3 kg -

F PR5, C200x75x20x2.3 kg -

G PR5A, C200x75x20x2.5 kg -

H R1, WF150x75x5x7-R kg -

I R2, WF200x100x5.5x8-R kg -

J R3, WF250x125x6x9-R kg -

K SB1, WF150x75x5x7-SB kg -

L SB3, WF250x125x6x9-SB kg -

M SB5, WF350x175x7x11-SB kg -

N SB6, WF400x200x8x13-SB kg -

O SB9, WF600x200x11x17-SB kg -

P SB10, UNP100x50-SB kg -

Q SB14, UNP200x90-SB kg -

R SB16A, L50x50x5-SB kg -

S SB21A, C150x65x20x2.3-SB kg -

T SB21D, C125x50x20x2.3 kg -

U SG2, WF200x100x5.5x8-SG kg -

V SG3, WF250x125x6x9-SG kg -

W SG5, WF350x175x7x11-SG kg -

X SG6, WF400x200x8x13-SG kg -

TA2459 Lesaffre Garuda 11/45 7046-92f7-20b4-d4c3-2.5


Item BILL NO. 92 92.5 METALS
Qty. Unit Rate Rupiahs
No MAINTENANCE AND UTILITIES

To Collection Rp. -

92.5.1 STRUCTURAL FRAMING, CONT'D

The following in steel structure in framing sanblasting and painting


finished ; from ground level to roof floor level; comprising wide flange
bolted to mild steel, cleats, welded to rafter; including all labour,
materials and plant in fabricating,erecting with welded and bolted shop
and site connections; assembling and erecting with welded and bolted
shop and site connections; and all necessaries as specified on
specification and drawing; steel grade as note on specifications ( ASTM
A-36 / BJ 37 for steel structure)
A SG8, WF500x200x10x16-SG kg -

B SG9, WF600x200x11x17-SG kg -

C SG9A, WF588x300x12x20-SG kg -

D TR2, Dia12-TR kg -

E All connecting plates, brackets, cleats, bolts, anchor bolts and stiffeners, Ls -
welding, including sandblasting and painted finish and all necessary
fixing accessories as described

92.5.2 STEEL STAIR

Supply and install steel stair complete with step, railing, base plate, kick
plate, and all neccesary fixing accessories and support as drawing and
specification
F Staircase 1 no -

G Staircase 3 no -

Supply and install cage ladder including landing step, connecting plates
and all fixing accessories and support as drawing and specification

H To Roof Level +10.37 nos -

I To Roof Level +13.00 nos -

92.5.3 RAILING

Supply and Install steel pipe railing including handrail support and knee
railing complete with kick plate, anchor bolt and all necessary fixing
accessories as drawings and specifications

J To staircase 3 m -

92.5.4 OTHERS

K Supply and install chequered plate 4.5mm thick including, support and m2 -
all necessary per drawings and specifications

L Supply and install galvanized steel grating 32mm thick including all m2 -
support and accessories per drawings and specifications

TA2459 Lesaffre Garuda 12/45 7046-92f7-20b4-d4c3-2.5


Item BILL NO. 92 92.5 METALS
Qty. Unit Rate Rupiahs
No MAINTENANCE AND UTILITIES

To Collection Rp. -

COLLECTIONS

Page 92.5 /1 -

Page 92.5 /2 -

TA2459 Lesaffre Garuda 13/45 7046-92f7-20b4-d4c3-2.5


Item BILL NO. 92 92.5 METALS
Qty. Unit Rate Rupiahs
No MAINTENANCE AND UTILITIES

92.5 METALS
CARRIED TO SUMMARY AT END OF BILL NO. 92 Rp. -

TA2459 Lesaffre Garuda 14/45 7046-92f7-20b4-d4c3-2.5


Item BILL NO. 92 92.7 THERMAL AND MOISTURE Qty Unit Rate Rupiahs
No. MAINTENANCE AND UTILITIES PROTECTION

92.7.1 FLASHING AND SHEET METAL

Supply and Install metal roof Klip Lok Optima 0.45 BMT fixed to steel
purlin including flashing, sealant, and all fixing accessories; all in
accordance with drawings and specifications

A To Roof and Canopy m2 -

Supply and Install Waterstop Colorbond finish fixed to metal roof sheet,
including sealant and all necessary fixing accessories; all in accordance with
drawings and specifications

B To Roof m -

Supply and Install Metal cladding Trimdek 0.45 BMT finish colorbond
fixed to steel structure, including sealant, over flow galvanized steel pipe
Ø2" 6000mm CTC, and all necessary fixing accessories; all in accordance
with drawings and specifications

C To Fascia m2 -

Supply and Install Metal Flashing 0.45 BMT finish colorbond fixed to steel
purlin, including sealant and all necessary fixing accessories; all in
accordance with drawings and specifications

D To Roof m -

92.7.2 ROOF SPECIALITIES

Supply and Install metal gutter 0.5mm with weatherproof sealant complete
with plate support, jointing and all necessary fixing accessories and support,
in accordance with manufacturer's recommendations, as drawings and
specifications

E To Roof Gutter m2 -

Supply and Install down pipe complete with overflow, steel clamp, support,
fitting, bracket, steel unp, and all fixing accessories; all in accordance with
drawings and specifications

F PVC Downpipe Ø4" m -

G Chromium roof drain strainer nos -

92.7 THERMAL AND MOISTURE PROTECTION


CARRIED TO SUMMARY AT END OF BILL NO. 92 Rp. -

TA2459 Lesaffre Garuda 15/45 7046-92f7-20b4-d4c3-2.7


Item BILL NO. 92
92.8 DOORS AND WINDOWS Qty. Unit Rate Rupiahs
No. MAINTENANCE AND UTILITIES

92.8.1 DOORS

Supply and install steel rolling doors including frames, hardwares, treshold,
steel plate, and all necessary accessories and fixing supports as drawings
and specifications

A 92.DE.001 nos -

B 92.DE.015 nos -

C 92.DE.016 nos -

D 92.DE.017 nos -

E 92.DE.018 nos -

F 92.DE.024 nos -

G 92.DE.025 nos -

Supply and install steel door including vision panel / louvre, frames,
hardwares, treshold, steel plate, and all fixing accessories and supports as
drawings and specifications

H 92.DE.026 nos -

I 92.DE.012 nos -

J 92.DE.013 nos -

K 92.DE.019 nos -

L 92.DE.020 nos -

Supply and install alumnium door including vision panel / louvre, frames,
hardwares, treshold, steel plate, and all fixing accessories and supports as
drawings and specifications

M 92.DQ.005 nos -

N 92.DQ.006 nos -

O 92.DQ.007 nos -

P 92.DQ.008 nos -

Q 92.DQ.009 nos -

R 92.DR.002 nos -

S 92.DR.003 nos -

T 92.DR.010 nos -

TA2459 Lesaffre Garuda 16/45 7046-92f7-20b4-d4c3-2.8


Item BILL NO. 92
92.8 DOORS AND WINDOWS Qty. Unit Rate Rupiahs
No. MAINTENANCE AND UTILITIES
To Collection Rp. -

92.8.1 DOORS, CONT'D

Supply and install alumnium door including vision panel / louvre, frames,
hardwares, treshold, steel plate, and all fixing accessories and supports as
drawings and specifications

A 92.DR.011 nos -

B 92.DR.014 nos -

C 92.DR.022 nos -

Supply and install glass door including frames, hardwares, treshold, steel
plate, and all fixing accessories and supports as drawings and specifications

D 92.DU.021 nos -

E 92.DU.023 nos -

92.8.2 WINDOWS

Supply and install aluminium fix window complete with laminated


tempered glass + clear glass, hardwares, and all necessary components,
fixing, accessories as drawing and specification.

F 92.WA.001 nos -

G 92.WA.002 nos -

H 92.WA.003 nos -

I 92.WA.004 nos -

J 92.WA.005 nos -

K 92.WA.006 nos -

L 92.WA.007 nos -

M 92.WA.008 nos -

N 92.WA.009 nos -

O 92.WA.010 nos -

P 92.WA.011 nos -

Q 92.WA.012 nos -

92.8.3 LOUVRES

Supply and install steel louvre complete with removable insect screen,
hardwares, and all necessary components, fixing, accessories as drawing
and specification.

R 92.LA.001 nos -

S 92.LA.002 nos -

TA2459 Lesaffre Garuda 17/45 7046-92f7-20b4-d4c3-2.8


Item BILL NO. 92
92.8 DOORS AND WINDOWS Qty. Unit Rate Rupiahs
No. MAINTENANCE AND UTILITIES

To Collection Rp. -

92.8.3 LOUVRES, CONT'D

Supply and install steel louvre complete with removable insect screen,
hardwares, and all necessary components, fixing, accessories as drawing
and specification.

A 92.LA.003 nos -

B 92.LA.004 nos -

C 92.LA.005 nos -

D 92.LA.006 nos -

E 92.LA.007 nos -

F 92.LA.008 nos -

G 92.LA.009 nos -

H 92.LA.010 nos -

I 92.LA.011 nos -

J 92.LA.012 nos -

K 92.LA.013 nos -

L 92.LA.014 nos -

M 92.LA.015 nos -

N 92.LA.016 nos -

O 92.LA.017 nos -

P 92.LA.018 nos -

Q 92.LA.019 nos -

R 92.LA.020 nos -

S 92.LA.021 nos -

T 92.LA.022 nos -

U 92.LA.023 nos -

V 92.LA.024 nos -

W 92.LA.025 nos -

X 92.LA.026 nos -

TA2459 Lesaffre Garuda 18/45 7046-92f7-20b4-d4c3-2.8


Item BILL NO. 92
92.8 DOORS AND WINDOWS Qty. Unit Rate Rupiahs
No. MAINTENANCE AND UTILITIES

To Collection Rp. -

92.8.4 CURTAIN WALL

Supply and install curtain wall system complete with hardwares, and all
necessary components, fixing, accessories as drawing and specification

A 92.SR.001 Size (2775x2800) 4 panel nos -

B 92.SZ.002 Size (6000x2800) 6 panel nos -

To Collection Rp. -

COLLECTIONS

Page 92.8 /1 -

Page 92.8 /2 -

Page 92.8 /3 -

Page 92.8 /4 -

TA2459 Lesaffre Garuda 19/45 7046-92f7-20b4-d4c3-2.8


Item BILL NO. 92
92.8 DOORS AND WINDOWS Qty. Unit Rate Rupiahs
No. MAINTENANCE AND UTILITIES

92.8 DOORS AND WINDOWS


CARRIED TO SUMMARY AT END OF BILL NO. 92 Rp. -

TA2459 Lesaffre Garuda 20/45 7046-92f7-20b4-d4c3-2.8


Item BILL NO. 92
92.9. FINISHES Qty. Unit Rate Rupiahs
No MAINTENANCE AND UTILITIES

92.9.1 FLOOR FINISHES

Prepare and apply anti acid/alkali/slippery tile; all in accordance with


manufacturer's instruction, drawings, and specifications

A To Floor m2 -

Prepare and apply epoxy quartz; all in accordance with manufacturer's


instruction, drawings, and specifications

B To Floor, incl. plinths m2 -

Supply and install Homogenous Tile complete with screed, gape grouting
and all in accordance with manufactured instruction applied: all in
accordance with drawings and specifications

C To Floor m2 -

D To Skirting m -

Supply and install Homogenous Tile Anti Skid complete with screed, gape
grouting and all in accordance with manufactured instruction applied: all in
accordance with drawings and specifications

E To Floor m2 -

F To Skirting m -

92.9.2 WALL FINISHES

Supply and install Homogenous Tile complete with screed, gape grouting
and all in accordance with manufactured instruction applied: all in
accordance with drawings and specifications

G To Toilet m2 -

Prepare smooth and apply waterbased acrylic emulsion paint finish, in


accordance with manufacturer's recommendations, as specified to face of :

H Applied to plastered autoclaved concrete walls (Internal Wall) m2 -

Prepare smooth and apply waterbased wethershield emulsion paint finish,


in accordance with manufacturer's recommendations, as specified to face of

I Applied to plastered autoclaved concrete walls (External Wall) m2 -

92.9.3 CEILING FINISHES

Prepare smooth and apply waterbased acrylic emulsion paint finish, in


accordance with manufacturer's recommendations, as specified to face of :

J To Calciboard Ceiling m2 -

K To Exposed Concrete

Prepare smooth and apply skimcoat, in accordance with manufacturer's


recommendations, as drawing and specification

L To Exposed Concrete m2 -

92.9. FINISHES

TA2459 Lesaffre Garuda 21/45 7046-92f7-20b4-d4c3-2.9


Item BILL NO. 92
92.9. FINISHES Qty. Unit Rate Rupiahs
No MAINTENANCE AND UTILITIES

CARRIED TO SUMMARY AT END OF BILL NO. 92 Rp. -

TA2459 Lesaffre Garuda 22/45 7046-92f7-20b4-d4c3-2.9


Item BILL NO. 92
92.10 SPECIALITIES Qty. Unit Rate Rupiahs
No MAINTENANCE AND UTILITIES

92.10.1 INTERIOR SPECIALITIES

Supply and install sanitary wares complete with all necessary in


accordance with manufacturer's recommendations as drawing and

A SF9, Toilet Cubicle nos -

B SF10, Toilet Seated nos -

C SF11, Floor Drain nos -

D SF12, Jet Shower nos -

E SF13, Urinoir nos -

F SF14, Urinal Partition nos -

G SF16, Self Closing nos -

H SF17, Under Counter Lavatory nos -

I SF19, Paper Towel Holder nos -

J SF23, Mirror Male Toilet nos -

K SF23, Mirror Female Toilet nos -

L SF24, Soap Dispenser nos -

M SF28, Paper Towel Dispenser nos -

N Shower nos -

92.10 SPECIALITIES

TA2459 Lesaffre Garuda 23/45 7046-92f7-20b4-d4c3-2.10


Item BILL NO. 92
92.10 SPECIALITIES Qty. Unit Rate Rupiahs
No MAINTENANCE AND UTILITIES

CARRIED TO SUMMARY AT END OF BILL NO. 92 Rp. -

TA2459 Lesaffre Garuda 24/45 7046-92f7-20b4-d4c3-2.10


Item BILL NO. 92
92.11 MECHANICAL WORKS Qty. Unit Rate Rupiahs
No MAINTENANCE AND UTILITIES

92.11 MECHANICAL WORKS

92.11.1 DOMESTIC COLD WATER

DOMESTIC COLD WATER SYSTEM INSTALLATION


Supply and install Domestic Water pipes; PPR PN 10 including fittings (for 50
mm dia. Pipe or less) fixed in position complete with seals (for underground
pipe) supports, hangers, brackets, clamp, painting, and other necessary fixing
and jointing material in accordance to the technical specification and drawings,
as described;

PIPEWORKS

A 15mm diameter pipe m

B 20mm diameter pipe m

C 25mm diameter pipe m

D 32mm diameter pipe m

E 40mm diameter pipe m

F 50mm diameter pipe m

VALVE AND ANCILLARIES

G 25mm diameter gate valve no

H 32mm diameter gate valve no

I 40mm diameter gate valve no

J 50mm diameter gate valve no

92.11.2 SEWAGE AND WASTE WATER SYSTEM

SEWAGE AND WASTE WATER SYSTEM INSTALLATION


Supply and Install Waste water, Sewage water pipes and Venting pipes; PVC Class
AW 10 kg/m2 including fittings (for 50 mm dia. Pipe or less) fixed in position
complete with supports, hangers, brackets, clamp, painting, and other necessary
fixing and jointing material in accordance to the technical specification and
drawings, as described;

PIPEWORKS (SEWAGE AND WASTE)

K 50mm diameter pipe m

L 100mm diameter pipe m

M 160mm diameter pipe m

N 200mm diameter pipe m

PIPEWORKS (VENTING)

O 40mm diameter pipe m

TA2459 Lesaffre Garuda 25/45 7046-92f7-20b4-d4c3-2.11


Item BILL NO. 92
92.11 MECHANICAL WORKS Qty. Unit Rate Rupiahs
No MAINTENANCE AND UTILITIES

To Collection Rp. -

TA2459 Lesaffre Garuda 26/45 7046-92f7-20b4-d4c3-2.11


Item BILL NO. 92
92.11 MECHANICAL WORKS Qty. Unit Rate Rupiahs
No MAINTENANCE AND UTILITIES

SEWAGE AND WASTE WATER SYSTEM INSTALLATION (Cont'd)


Supply and Install Waste water, Sewage water pipes and Venting pipes; PVC Class
AW 10 kg/m2 including fittings (for 50 mm dia. Pipe or less) fixed in position
complete with supports, hangers, brackets, clamp, painting, and other necessary
fixing and jointing material in accordance to the technical specification and
drawings, as described;

PIPEWORKS (VENTING)

A 50mm diameter pipe m

FITTINGS

B Fitting 110mm diameter no

C Fitting 160mm diameter no

D Fitting 200mm diameter no

VALVE AND ANCILLARIES

E Ventcap 50mm diameter no

F Clean out 50mm diameter no

G Clean out 100mm diameter no

92.11.3 HYDRANT & SPRINKLER SYSTEM

HYDRANT SYSTEM INSTALLATION


Supply and install Hydrant pipes, Black steel pipe to ASTM A 53 schedule 40 ,
Grade B, including fitting (for 50 mm dia. Pipe or less) fixed in position complete
with supports, hangers, brackets, clamp, painting, and other necessary fixing and
jointing material in accordance to the technical specification and drawings, as
described;

PIPEWORKS

H 40mm diameter pipe m

I 65mm diameter pipe m

J 80mm diameter pipe m

K 100mm diameter pipe m

L 150mm diameter pipe m

FITTINGS

M Fitting 65mm diameter no

N Fitting 80mm diameter no

TA2459 Lesaffre Garuda 27/45 7046-92f7-20b4-d4c3-2.11


Item BILL NO. 92
92.11 MECHANICAL WORKS Qty. Unit Rate Rupiahs
No MAINTENANCE AND UTILITIES

To Collection Rp. -

TA2459 Lesaffre Garuda 28/45 7046-92f7-20b4-d4c3-2.11


Item BILL NO. 92
92.11 MECHANICAL WORKS Qty. Unit Rate Rupiahs
No MAINTENANCE AND UTILITIES

HYDRANT SYSTEM INSTALLATION (Cont'd)


Supply and install Hydrant pipes, Black steel pipe to ASTM A 53 schedule 40 ,
Grade B, including fitting (for 50 mm dia. Pipe or less) fixed in position complete
with supports, hangers, brackets, clamp, painting, and other necessary fixing and
jointing material in accordance to the technical specification and drawings, as
described;

FITTINGS

A Fitting 100mm diameter no

B Fitting 150mm diameter no

VALVE AND ANCILLARIES

C 80mm diameter gate valve, UL listed & FM approved no

D Portable fire extinguisher with capacity 4.5 kg chemical powder ABC type. no

E Portable fire extinguisher with capacity 6 kg chemical powder ABC type. no

F Portable fire extinguisher with capacity 6 kg chemical powder C02 type. no

G Indoor Hydrant Box (IHB) complete with hose rack, rubber hose, hose reel, valve no
and nozzle

SPRINKLER SYSTEM INSTALLATION


Supply and install Sprinkler pipes, Black steel pipe to ASTM A 53 schedule 40 ,
Grade B, including fitting (for 50 mm dia. Pipe or less) fixed in position complete
with supports, hangers, brackets, clamp, painting, and other necessary fixing and
jointing material in accordance to the technical specification and drawings, as
described;

PIPEWORKS

H 25mm diameter pipe m

I 32mm diameter pipe m

J 40mm diameter pipe m

K 50mm diameter pipe m

L 65mm diameter pipe m

M 80mm diameter pipe m

N 100mm diameter pipe m

O 150mm diameter pipe m

P 200mm diameter pipe m

FITTINGS

Q Fitting 65mm diameter no

TA2459 Lesaffre Garuda 29/45 7046-92f7-20b4-d4c3-2.11


Item BILL NO. 92
92.11 MECHANICAL WORKS Qty. Unit Rate Rupiahs
No MAINTENANCE AND UTILITIES

To Collection Rp. -

TA2459 Lesaffre Garuda 30/45 7046-92f7-20b4-d4c3-2.11


Item BILL NO. 92
92.11 MECHANICAL WORKS Qty. Unit Rate Rupiahs
No MAINTENANCE AND UTILITIES

SPRINKLER SYSTEM INSTALLATION (Cont'd)


Supply and install Sprinkler pipes, Black steel pipe to ASTM A 53 schedule 40 ,
Grade B, including fitting (for 50 mm dia. Pipe or less) fixed in position complete
with supports, hangers, brackets, clamp, painting, and other necessary fixing and
jointing material in accordance to the technical specification and drawings, as
described;

FITTINGS

A Fitting 80mm diameter no

B Fitting 100mm diameter no

C Fitting 150mm diameter no

D Fitting 200mm diameter no

VALVE AND ANCILLARIES

E Head sprinkler pendant type no

F Head sprinkler upright type no

G Branch Control Valve (BCV); 80mm diameter set

H Branch Control Valve (BCV); 100mm diameter set

H Alarm Control Valve (ACV); 150mm diameter set

I AAV; 25mm diameter no

J Test Drain; 25 mm diameter set

K Flexible coupling; 150mm diameter no

To Collection Rp. -

COLLECTION

Page 92.11 /1 -

Page 92.11 /2 -

Page 92.11 /3 -

Page 92.11 /4 -

92.11 MECHANICAL WORKS


CARRIED TO SUMMARY AT END OF BILL NO. 92 Rp. -

TA2459 Lesaffre Garuda 31/45 7046-92f7-20b4-d4c3-2.11


Item BILL NO. 92
92.11 MECHANICAL WORKS Qty. Unit Rate Rupiahs
No MAINTENANCE AND UTILITIES

TA2459 Lesaffre Garuda 32/45 7046-92f7-20b4-d4c3-2.11


Item BILL NO. 92
92.12 ELECTRICAL WORKS Qty. Unit Rate Rupiahs
No MAINTENANCE AND UTILITIES

92.12 ELECTRICAL WORKS

92.12.1 SUB DISTRIBUTION BOARDS


Supply, Install and Testing Commissioning the following Sub Distribution board
fix in position includes circuit breaker, board, busbar, digital multimeter,
contactor, surge arrester, potensial transformer, current transformer, indicator
lamp, fuse, loto, star / stop push button, and all necessary accessories in
arcondance to the technical spesification as shown on drawing, as described : -

A 92DB01 no

B 92DBAC01 no

92.12.2 MAIN AND SUB-MAINS CABLES


Supply and Install the following Main and Sub-Mains circuit distribution cable
run & fixed on cable tray/ladders including all necessary accessories in
arcondance to the technical spesification as shown on drawing, as described : -

C From SDB…. to 92DB01 m by other package

92.12.3 LIGHTING FIXTURES & POWER OUTLET


Supply and Install the following light fittings including tubes or lamps fixed in
position complete with all accessories and support in accordance with the
technical specification and drawings, as described :-

D High bay LED 150W, 20501 lm no

E Recessed mounted TLED 40W, 220V, 3709 lm no

F Recessed mounted TLED 40W, 220V, 3709 lm, c/w nicad battery duration 1 no
hour

G Exit sign LED 5W, 220V, wall mounted no

H Waterproof LED 20W, 220V, IP65, 2000 lm, L600 no

I Waterproof LED 20W, 220V, IP65, 2000 lm, L600, c/w nicad battery duration 1 no
hour

J Waterproof LED 40W, 220V, IP65, 4000 lm, L1200 no

K Waterproof LED 40W, 220V, IP65, 4000 lm, L1200, c/w nicad battery duration no
1 hour

L Flood light LED 100W, 9500 lm no

M Downlight 16W, 220V, minimum 1200 lm no

N Downlight 16W, 220V, minimum 1200 lm, c/w nicad battery duration 1 hour no

O Batten LED 40W, 220V 4100 lm no

To Collection Rp. -

TA2459 Lesaffre Garuda 33/45 7046-92f7-20b4-d4c3-2.12


Item BILL NO. 92
92.12 ELECTRICAL WORKS Qty. Unit Rate Rupiahs
No MAINTENANCE AND UTILITIES

92.12.3 LIGHTING FIXTURES & POWER OUTLET (Cont'd)


Supply and Install the following switches including provision of steel/metal box
and all accessories accordance with the technical specification and drawings, as
described :-

A Single gang, 1 way switch, 10A no

B Double gang, 1 way switch, 10A no

Supply and Install lighting & switch cables from sub circuit to final circuit
including grounding system and all neccessary accessories accordance with the
technical specification and drawings, as described :-

C Cabling point from local panel (500V/CU/PVC 3C x 2.5 mm² shall be UV & no
chemical resistance) run-in and with PVC high impact conduit) to; lighting and
switch

POWER OUTLET
Supply and Install the following power outlet including provision of steel/metal
box and all accessories accordance with the Technical Specification and
drawings, as described :-

D General socket outlet, wall mounted, 16A, 250V, single gang no

E General socket outlet, wall mounted, 16A, 250V, double gang no

F General socket outlet c/w cover, wall mounted, 16A, 250V, (waterproof) single no
gang

G General socket outlet hand dryer, wall mounted, 16A, 250V, (waterproof) single no
gang

H General socket outlet c/w cover outbow type, wall mounted, 16A, 250V, no
(waterproof) single gang

I Industrial socket outlet, wall mounted 16A, 250V, IP65, 1Ph no

J Industrial socket outlet, wall mounted 32A, 400V, IP65, 3Ph no

92.12.4 TRAYS AND LADDERS


Supply and Install hot dip galvanized tray and ladder 2mm thickness include
jointing, elbow, tee, fixing accessories and hangers and all necessary accessories
accordance with the technical specification and drawings, as described :-

Electrical
K Cable tray 300x100mm m

L Cable ladder 300x100mm m

Electronic
M Cable tray 200x100mm m

To Collection Rp. -

TA2459 Lesaffre Garuda 34/45 7046-92f7-20b4-d4c3-2.12


Item BILL NO. 92
92.12 ELECTRICAL WORKS Qty. Unit Rate Rupiahs
No MAINTENANCE AND UTILITIES

92.12.5 GROUNDING & LIGHTNING PROTECTION SYSTEM (Cont'd)


Supply and Install Grounding system for panel and equipment complete with
support and all neccessary accessories accordance with the technical
specification and drawings, as described :-

A Earth pit, Conductor clamp and rod electrode, dia 19mm x 3000 length no

B Earthing bonding bar (copper bar) 50x3mm thk, c/w isolator no

C BC 70mm2, grounding cable for main/mesh earthing c/w connector and m


grounding lug

D Potential earth clamp (100kA) no

E Bonding cable NYAF 16mm2 m

F Bonding cable NYAF 25mm2 m

G Bonding cable NYAF 35mm2 m

H Bonding cable NYAF 50mm2 m

92.12.6 FIRE ALARM


Supply and Install the following Fire Alarm Equipment complete with support, and
all necessary accessories in accordance to the technical specification and
drawings, as described : -

I JBFA-92-01 no

J Addressable photoelectric smoke detector no

K Addressable fixed heat detector no

L Addressable manual call point no

M Horn & strobe light no

N Beam detector transmitter no

O Beam detector receiver no

P End of line (EOL) no

Supply and Install the following Fire Alarm cables in final sub-circuit to
termination, run-in and with steel conduit 20mm dia; including earthing system
and all necessary accessories in accordance to the technical spesification as
shown on drawing, as described : -

Q Power Cable FRC 2Cx2,5 mm2; from control room BD50 m

R Cable FRC STP 2Cx1,5 mm2; for detector point no

S Cable FRC STP 2Cx1,5 mm2; for manual call point no

T Cable FRC 2Cx1,5 mm2; for horn & strobe light point no

To Collection Rp. -

TA2459 Lesaffre Garuda 35/45 7046-92f7-20b4-d4c3-2.12


Item BILL NO. 92
92.12 ELECTRICAL WORKS Qty. Unit Rate Rupiahs
No MAINTENANCE AND UTILITIES

92.12.7 PUBLIC ADDRESS


Supply and Install the following Sound System Equipment complete with support,
and all necessary accessories in accordance to the technical specification and
drawings, as described : -

A Wall mounted switch rack JBPA-92-01 (SR-92-01) no

B Indoor ceiling mounted speaker 6W no

C Horn speaker 15W no

Supply and Install the following Public Address cables in final sub-circuit to
termination, run-in and with steel conduit 20mm dia; including earthing system
and all necessary accessories in accordance to the technical spesification as
shown on drawing, as described : -

D Cable FO OM3; from BD96 m

E Cable NYMHY 2Cx1,5 mm2; for indor ceiling speaker point no

F Cable NYMHY 2Cx1,5 mm2; for horn speaker point no

92.12.8 DATA AND TELEPHONE


Supply and Install the following Data and Communication System
Equipment complete with support, and all necessary accessories in
accordance to the technical specification and drawings, as described : -

G Wall mounted switch rack SR-92-01 no

H Single gang type data outlet (RJ45) no

I Single gang type telephone outlet (RJ45) no

Supply and Install the following Data and Telephone cables in final sub-circuit
to termination, run-in and with steel conduit 20mm dia; including earthing system
and all necessary accessories in accordance to the technical spesification as
shown on drawing, as described : -

J Cable UTP-CAT6/FO mm2; for data outlet point no

K Cable UTP-CAT6/FO mm2; for data outlet point no

L Cable UTP-CAT6/FO mm2; for telephone outlet point no

M Cable FO OM3; from BD96 m

92.12.9 SECURITY SYSTEM


Supply and Install the following Security System Equipment complete with
support, and all necessary accessories in accordance to the technical specification
and drawings, as described : -

M Wall mounted switch rack SR-50-01 no

N IP based bullet fix camera indoor type no

To Collection Rp. -

TA2459 Lesaffre Garuda 36/45 7046-92f7-20b4-d4c3-2.12


Item BILL NO. 92
92.12 ELECTRICAL WORKS Qty. Unit Rate Rupiahs
No MAINTENANCE AND UTILITIES

92.12.9 SECURITY SYSTEM (Cont'd)


Supply and Install the following Security System Equipment complete with
support, and all necessary accessories in accordance to the technical specification
and drawings, as described : -

A IP based dome camera no

B Acces control door consist of; no


Door control
Finger print / card reader
Push button door release

Supply and Install the following Security cables in final sub-circuit to


termination, run-in and with PVC conduit 25mm dia underground direct burried
min 500mm below grade or through pipe rack; including earthing system and all
necessary accessories in accordance to the technical spesification as shown on
drawing, as described : -

C Cable UTP-CAT6/FO; for bullet fix camera indoor type point no

D Cable UTP-CAT6/FO; for bullet dome camera no

E Cable UTP-CAT6/FO; for acces control door point no

F Cable FO OM3; from BD96 m

To Collection Rp. -

COLLECTIONS

Page 92.12 /1 -

Page 92.12 /2 -

Page 92.12 /3 -

Page 92.12 /4 -

Page 92.12 /5 -

92.12 ELECTRICAL WORKS


CARRIED TO SUMMARY AT END OF BILL NO. 92 Rp. -

TA2459 Lesaffre Garuda 37/45 7046-92f7-20b4-d4c3-2.12


Item BILL NO. 92
92.13 HVAC WORKS Qty. Unit Rate Rupiahs
No MAINTENANCE AND UTILITIES

92.13 HVAC WORKS

92.13.1 EQUIPMENT

VRF UNIT
Supply and Install of VRF Units complete with hangers/supports, vibration
mountings, neoprene pads and all necessary accessories in accordance to
the technical specification and drawings, as described : -

A IU-VRF.92.00.01; high static split duct, cooling capacity 22kWth, supply no


air flow 1321 CMH, static pressure 220 pa, 1.1kW, 380V/3Ph/50Hz

B IU-VRF.92.00.02; high static split duct, cooling capacity 28kWth, supply no


air flow 1996 CMH, static pressure 220 pa, 1.1kW, 380V/3Ph/50Hz

C IU-VRF.92.00.03; wall mounted, cooling capacity 3kWth, supply air no


flow 510 CMH, free blow, 0.1kW, 220V/1Ph/50Hz

D IU-VRF.92.00.04; wall mounted, cooling capacity 2.4kWth, supply air no


flow 468 CMH, free blow, 0.1kW, 220V/1Ph/50Hz

E IU-VRF.92.00.05; ceiling suspend, cooling capacity 7.2kWth, supply air no


flow 1260 CMH, free blow, 0.1kW, 220V/1Ph/50Hz

F IU-VRF.92.02.01A-B; high static split duct, cooling capacity 22kWth, supply no


air flow 3480 CMH, static pressure 220 pa, 1.1kW, 380V/3Ph/50Hz

G IU-VRF.92.02.01C; high static split duct, cooling capacity 9.8kWth, supply no


air flow 1938 CMH, static pressure 150 pa, 0.55kW, 220V/1Ph/50Hz

H IU-VRF.92.02.02A-B; 2 way cassete, cooling capacity 2.2kWth, supply no


air flow 648 CMH, free blow, 0.1kW, 220V/1Ph/50Hz

I IU-VRF.92.02.03; 2 way cassete, cooling capacity 3.5kWth, supply no


air flow 708 CMH, free blow, 0.1kW, 220V/1Ph/50Hz

J IU-VRF.92.02.04; wall mounted, cooling capacity 1.6kWth, supply no


air flow 708 CMH, free blow, 0.1kW, 220V/1Ph/50Hz

K OU-VRF.92.00.01; inverter, cooling capacity 3.7kWth, supply


air flow 12600 CMH/module, static pressure 75 pa, 7kW, 380V/3Ph/50Hz

L OU-VRF.92.00.02; inverter, cooling capacity 3.2kWth, supply


air flow 4020 CMH/module, static pressure 86 pa, 5.5kW, 380V/3Ph/50Hz

M OU-VRF.92.02.01; inverter, cooling capacity 3.4kWth, supply


air flow 12600 CMH/module, static pressure 80 pa, 8kW, 380V/3Ph/50Hz

HEAT EXCHANGER UNIT


Supply and Install of Heat Exchanger Units complete with hangers/supports, vibration
mountings, neoprene pads and all necessary accessories in accordance to
the technical specification and drawings, as described : -

N HEXV-92.02.01, heat exchanger, air flow 746 CMH, static pressure 150 pa, no
0.55kW, 220V/1Ph/50Hz

To Collection Rp. -

TA2459 Lesaffre Garuda 38/45 7046-92f7-20b4-d4c3-2.13


Item BILL NO. 92
92.13 HVAC WORKS Qty. Unit Rate Rupiahs
No MAINTENANCE AND UTILITIES

92.13.1 EQUIPMENT (Cont'd)

FAN
Supply and Install of Fan Units complete with hangers/supports, vibration
mountings, neoprene pads and all necessary accessories in accordance to the
technical specification and drawings, as described : -

A Exhasut Fan EF-92.00.01, mixflow inline type, cap 1260 CMH, static pressure no
294 pa, 0.37kW, 220V/1Ph/50Hz

B Exhasut Fan EF-92.00.02, centrifugal with accoustic case type, cap 2110 CMH, no
static pressure 284 pa, 0.37kW, 220V/1Ph/50Hz

C Exhasut Fan EF-92.00.03, mixflow inline type, cap 448 CMH, static pressure no
221 pa, 0.37kW, 220V/1Ph/50Hz

D Exhasut Fan EF-92.00.04A-D, axial wall mounted type, cap 6654 CMH, static no
pressure 113 pa, 0.55kW, 380V/3Ph/50Hz

92.13.2 DUCTWORK
Supply and Install galvanized steel sheet ductworks complete with hangers,
supports, brackets and all necessary fixing accessories in accordance to the
technical tpecification and drawings, as described :-

SUPPLY AIR DUCT


With external insulation (closed cell elastomeric fire retardant type class 0,
FM Approved, 50mm thickness + AL sheet Jacketing 0.4mm thckness)

E Supply air duct (SAD) ; 500x400mm m

F Supply air duct (SAD) ; 500x300mm m

G Supply air duct (SAD) ; 400x300mm m

H Supply air duct (SAD) ; 400x250mm m

I Supply air duct (SAD) ; 300x300mm m

J Supply air duct (SAD) ; 400x200mm m

K Supply air duct (SAD) ; 250x250mm m

L Supply air duct (SAD) ; 250x200mm m

M Supply air duct (SAD) ; 200x200mm m

N Supply air duct (SAD) ; 150x150mm m

FRESH AIR DUCT


With external insulation (closed cell elastomeric fire retardant type class 0,
FM Approved, 32mm thickness + AL sheet Jacketing 0.4mm thckness)

O Fresh air duct (FAD) ; 400x300mm m

P Fresh air duct (FAD) ; 400x200mm m

To Collection Rp. -

TA2459 Lesaffre Garuda 39/45 7046-92f7-20b4-d4c3-2.13


Item BILL NO. 92
92.13 HVAC WORKS Qty. Unit Rate Rupiahs
No MAINTENANCE AND UTILITIES

TA2459 Lesaffre Garuda 40/45 7046-92f7-20b4-d4c3-2.13


Item BILL NO. 92
92.13 HVAC WORKS Qty. Unit Rate Rupiahs
No MAINTENANCE AND UTILITIES

92.13.2 DUCTWORK (Cont'd)


Supply and Install galvanized steel sheet ductworks complete with hangers,
supports, brackets and all necessary fixing accessories in accordance to the
technical tpecification and drawings, as described :-

FRESH AIR DUCT


With external insulation (closed cell elastomeric fire retardant type class 0,
FM Approved, 32mm thickness + AL sheet Jacketing 0.4mm thckness)

A Fresh air duct (FAD) ; 300x200mm m

B Fresh air duct (FAD) ; 200x200mm m

C Fresh air duct (FAD) ; 200x150mm m

D Fresh air duct (FAD) ; 150x150mm m

RETURN AIR DUCT


With external insulation (closed cell elastomeric fire retardant type class 0,
FM Approved, 32mm thickness + AL sheet Jacketing 0.4mm thckness)

E Return air duct (RAD) ; 500x400mm m

F Return air duct (RAD) ; 500x300mm m

G Return air duct (RAD) ; 400x300mm m

H Return air duct (RAD) ; 400x250mm m

I Return air duct (RAD) ; 300x250mm m

J Return air duct (RAD) ; 250x250mm m

EXHAUST AIR DUCT


With external insulation (closed cell elastomeric fire retardant type class 0,
FM Approved, 25mm thickness + AL sheet Jacketing 0.4mm thckness)

K Exhaust air duct (EAD) ; 600x600mm m

L Exhaust air duct (EAD) ; 500x200mm m

M Exhaust air duct (EAD) ; 400x200mm m

N Exhaust air duct (EAD) ; 350x200mm m

O Exhaust air duct (EAD) ; 300x200mm m

P Exhaust air duct (EAD) ; 300x150mm m

Q Exhaust air duct (EAD) ; 250x200mm m

R Exhaust air duct (EAD) ; 250x150mm m

S Exhaust air duct (EAD) ; 225x325mm m

To Collection Rp. -

TA2459 Lesaffre Garuda 41/45 7046-92f7-20b4-d4c3-2.13


Item BILL NO. 92
92.13 HVAC WORKS Qty. Unit Rate Rupiahs
No MAINTENANCE AND UTILITIES

TA2459 Lesaffre Garuda 42/45 7046-92f7-20b4-d4c3-2.13


Item BILL NO. 92
92.13 HVAC WORKS Qty. Unit Rate Rupiahs
No MAINTENANCE AND UTILITIES

92.13.2 DUCTWORK (Cont'd)


Supply and Install galvanized steel sheet ductworks complete with hangers,
supports, brackets and all necessary fixing accessories in accordance to the
technical tpecification and drawings, as described :-

EXHAUST AIR DUCT


With external insulation (closed cell elastomeric fire retardant type class 0,
FM Approved, 25mm thickness + AL sheet Jacketing 0.4mm thckness)

A Exhaust air duct (EAD) ; 225x225mm m

B Exhaust air duct (EAD) ; 200x200mm m

C Exhaust air duct (EAD) ; 200x150mm m

D Exhaust air duct (EAD) ; 150x150mm m

E Exhaust air duct (EAD) ; 150mm diameter m

92.13.3 GRILLE AND DIFFUSER

Supply and Install Diffuser, Grilles and Volume Damper complete with air
equalising deflector blades, plenum box (if any) and all necessary
accessories including fixing, frame and connecting to ductwork in
accordance with the technical specification and drawings, as described :-

F Supply air diffuser (SAD) ; 225x225mm no

G Supply air diffuser (SAD) ; 300x300mm no

H Supply air diffuser (SAD) ; 400x400mm no

I Supply air diffuser (SAD) ; 500x500mm no

J Intake air louvre (IAL) ; 600x330mm no

K Intake air louvre (IAL) ; 1200x330mm no

L Fresh air louvre (EAG) ; 660x330mm no

M Return air grille (RAG) ; 525x225mm no

N Exhaust air grille (EAG) ; 225x225mm no

O Exhaust air grille (EAG) ; 325x225mm no

P Exhaust air grille (EAG) ; 525x225mm no

Q Exhaust air louvre (EAL) ; 400x330mm no

R Exhaust air louvre (EAL) ; 600x330mm no

S Exhaust air louvre (EAL) ; 800x330mm no

TA2459 Lesaffre Garuda 43/45 7046-92f7-20b4-d4c3-2.13


Item BILL NO. 92
92.13 HVAC WORKS Qty. Unit Rate Rupiahs
No MAINTENANCE AND UTILITIES

To Collection Rp. -

TA2459 Lesaffre Garuda 44/45 7046-92f7-20b4-d4c3-2.13


Item BILL NO. 92
92.13 HVAC WORKS Qty. Unit Rate Rupiahs
No MAINTENANCE AND UTILITIES

92.13.2 REFRIGERANT & DRAIN PIPES


Supply and install the following Refrigerant Copper Pipeworks including
FM Approved insulation ,vapour barrier, trap, fittings (for 50mm diameter
pipe or less), joints, flanges, support and all accessories in accordance to
the technical specification and drawings, as described : -

A 6.5 mm diameter pipe copper c/w insulation m

B 9,5 mm diameter pipe copper c/w insulation m

C 12,7 mm diameter pipe copper c/w insulation m

D 15,8 mm diameter pipe copper c/w insulation m

E 22,2 mm diameter pipe copper c/w insulation m

DRAIN PIPES
F 25 mm diameter pipe PVC Class AW c/w insulation m

G 32 mm diameter pipe PVC Class AW c/w insulation m

To Collection Rp. -

COLLECTIONS

Page 92.13 /1 -

Page 92.13 /2 -

Page 92.13 /3 -

Page 92.13 /4 -

Page 92.13 /5 -

92.13 HVAC WORKS


CARRIED TO SUMMARY AT END OF BILL NO. 92 Rp. -

TA2459 Lesaffre Garuda 45/45 7046-92f7-20b4-d4c3-2.13


BILL NO. 94
GUARD HOUSE

TA2459 Lesaffre Garuda 1/24 72ae-1b3b-55d9-5dc4-Cover


Item BILL NO. 94 SUMMARY RUPIAHS
No. GUARD HOUSE

SUMMARY

94.1 DEMOLITION N/A

94.2 EARTHWORK -

94.3 CONCRETE -

94.4 MASONRY -

94.5 METALS -

94.7 THERMAL AND MOISTURE PROTECTION -

94.8 DOORS AND WINDOWS -

94.9. FINISHES -

94.10 SPECIALITIES -

94.11 MECHANICAL WORKS -

94.12 ELECTRICAL WORKS -

94.13 HVAC WORKS -

BILL NO. 94
CARRIED TO SUMMARY -

TA2459 Lesaffre Garuda 2/24 72ae-1b3b-55d9-5dc4-Sum


Item BILL NO. 94 Qty Unit Rate Rupiahs
94.2 EARTHWORK
No. GUARD HOUSE

94.2.1 EARTHWORK

Excavation, disposal and backfill in any material including rock or hard


material, working space at parimeter items as defined; Excavating, starting
from stripped level, trenches to receive depth as pecified (insite area)

A To Footings m3

B To Slab incl. ramp m3

C To Tie Beam m3

D To Column m3

E To Weighe Bridge m3

94.2.2 BASE COURSES

Compacted of subgrade to 95% Standard Proctor Density as specified

F To Footings m2

G To Slab incl. ramp m2

H To Tie Beam m2

I To Weighe Bridge m2

Sandfill 100mm thick as specified

J To Footings m2

K To Slab m2

L To Tie Beam m2

M To Weighe Bridge m2

Compacted gravel 200mm thick as specified

N To Under Ramp and Perimeter m2

94.2.3 TERMITE CONTROL

Termite control to soil; The protection against termites by spraying an


insecticide on the soil or on the fill before placing the vapor and after
building completed and importing landfill; undertaken by an approved
specialist; (5 years quarantee to be given) as specified.

O To Footings m2

P To Slab incl. ramp m2

Q To Tie Beam m2

R To Column m2

S To Weighe Bridge m2

TA2459 Lesaffre Garuda 3/24 72ae-1b3b-55d9-5dc4-2.2


Item BILL NO. 94 Qty Unit Rate Rupiahs
94.2 EARTHWORK
No. GUARD HOUSE

To Collection Rp. -

94.2.4 OTHERS

Plastic sheet

A To Footings m2

B To Perimeter Slab m2

C To Tie Beam m2

D To Weighe Bridge m2

To Collection Rp. -

COLLECTIONS

Page 94.2/1 -

Page 94.2/2 -

94.2 EARTHWORK

TA2459 Lesaffre Garuda 4/24 72ae-1b3b-55d9-5dc4-2.2


Item BILL NO. 94 Qty Unit Rate Rupiahs
94.2 EARTHWORK
No. GUARD HOUSE

CARRIED TO SUMMARY AT END OF BILL NO. 94 Rp. -

TA2459 Lesaffre Garuda 5/24 72ae-1b3b-55d9-5dc4-2.2


Item BILL NO. 94
94.3 CONCRETE Qty. Unit Rate Rupiahs
No. GUARD HOUSE

94.3.1 FORMWORK

94.3.1.1 IN GROUND FORMWORK

The design, certification, construction and performance of the formwork,


falsework and backpropping shall be the responsibilty of Contractor.
Proposed method of installation and removal of formwork is to be
submitted to the Superintendent for comment prior to work being carried
out as per dwg note.
In ground formwork as follows; permanent formwork system for in-place
concrete, concrete hollow block 100mm thick, finish starting at/from any
level and including rebates or grooves formers as described to

A To Footings m2 -

B To Ground Slab m2 -

C To Tie Beam m2 -

D To Weighe Bridge m2 -

94.3.1.2 UPPER STRUCTURE FORMWORK

Smooth-Formed Finished concrete, plywood, metal, or other approved


panel materials, finish starting at/from any level and rebates or groove
formers as specified

E To Upper Slab Incl. Roof Canopy m2 -

F To Beam m2 -

G To Column m2 -

H To Gutter m2 -

I To Wall/Parapet/Bundwall m2 -

94.3.2 CONCRETE

In-Situ Concrete

In-situ concrete designed mix Grade 30 Mpa, (K-350) NFA; ± 20mm


aggregate, vibrated with standard flatness as described ;

J To Footings m3 -

K To Ground and Upper Slab Incl. Roof Canopy m3 -

L To Tie Beam and Upper Beam m3 -

M To Column m3 -

N To Wall m3 -

O To Gutter m3 -

P To Weighe Bridge m3 -

TA2459 Lesaffre Garuda 6/24 72ae-1b3b-55d9-5dc4-2.3


Item BILL NO. 94
94.3 CONCRETE Qty. Unit Rate Rupiahs
No. GUARD HOUSE

To Collection Rp. -

94.3.2 CONCRETE, CONT'D

Lean Concrete

Plain in-situ concrete, designed mix grade f'c= Mpa,(K-125), 40mm


aggregate, 50mm thick as described,

A To Footings m2 -

B To Slab m2 -

C To Tie Beam m2 -

D To Weighe Bridge m2 -

94.3.3 REINFORCEMENT

Manufacture reinforcement bars is according to "Manual of Standard


Practice" CRSI's as follows; supply, cleaned, measurement, positioning,
setting and install. Reinforcement measure include joint dowel bars,
bolsters, chairs, spacers and other device for spacing, supporting and
fastening reinforcing bars and welded wire reinforcement in place.

Reinforcing bars is Grade 60/420 deformed or Grade BJTD 40 deformed.


round mild steel, as described in

E Dia. 13mm, To Footings kg -

G Dia. 13mm To Slab Incl. Roof Canopy kg -

H Dia. 16mm, To Tie Beam and Upper Beam kg -

I Dia. 13mm, To Tie Beam and Upper Beam kg -

J Dia. 10mm, To Tie Beam and Upper Beam kg -

K Dia. 16mm, To Column kg -

L Dia. 13mm, To Column kg -

M Dia. 10mm, To Column kg -

N Dia. 10mm, To Wall/Parapet/Bundwall kg -

O Dia. 8mm, To Wall/Parapet/Bundwall kg -

P Dia. ..mm, To Gutter kg -

Q Dia. ..mm, To Gutter kg -

R Dia. ..mm, To Weighe Bridge kg -

S Dia. ..mm, To Weighe Bridge kg -

TA2459 Lesaffre Garuda 7/24 72ae-1b3b-55d9-5dc4-2.3


Item BILL NO. 94
94.3 CONCRETE Qty. Unit Rate Rupiahs
No. GUARD HOUSE

To Collection Rp. -

94.3.4 OTHERS

Weighing bridge

A Side Curbing m -

B PVC pipe Ø2" access to weiging home m -

C Pipe arde m -

D Make a hole no -

To Collection Rp. -

COLLECTIONS

Page 94.3 /1 -

Page 94.3 /2 -

Page 94.3 /3 -

TA2459 Lesaffre Garuda 8/24 72ae-1b3b-55d9-5dc4-2.3


Item BILL NO. 94
94.3 CONCRETE Qty. Unit Rate Rupiahs
No. GUARD HOUSE

94.3 CONCRETE
CARRIED TO SUMMARY AT END OF BILL NO. 94 Rp. -

TA2459 Lesaffre Garuda 9/24 72ae-1b3b-55d9-5dc4-2.3


Item BILL NO. 94
94.4 MASONRY Qty. Unit Rate Rupiahs
No GUARD HOUSE

94.4.1 UNIT MASONRY

Supply and Install Autoclaved aerated concrete block wall with mortar;
including reinforced concrete bonding ties, anchorage, latching, stiffener
columns and lintels beams as required, all in accordancce with drawings
and specifications
A To Wall 150mm thick External Wall m2 -

B To Wall 150mm thick Internal Wall m2 -

94.4.2 PLASTERED

Plaster; Mortar instant trowelled smooth with and including cement coating
instant as described

C To Wall 150mm thick m2 -

94.4.3 CEILING

Supply and install calsium silicate board 6mm glued in gypsum ceiling
including ceiling suspension system and fixing accessories all in
accordance with drawings and specifications

D To Ceiling m2 -

94.4 MASONRY
CARRIED TO SUMMARY AT END OF BILL NO. 94 Rp. -

TA2459 Lesaffre Garuda 10/24 72ae-1b3b-55d9-5dc4-2.4


Item BILL NO. 94 94.5 METALS
Qty. Unit Rate Rupiahs
No GUARD HOUSE

94.5.1 STRUCTURAL FRAMING

The following in steel structure in framing sanblasting and painting


finished ; from ground level to roof floor level; comprising wide flange
bolted to mild steel, cleats, welded to rafter; including all labour,
materials and plant in fabricating,erecting with welded and bolted shop
and site connections; assembling and erecting with welded and bolted
shop and site connections; and all necessaries as specified on
specification and drawing; steel grade as note on specifications ( ASTM
A-36 / BJ 37 for steel structure)
A Weighing Bridge lot by others

B Protector steel angle 100x100x10 kg -

C Foundation steel plate m2 -

D Transom steel plate m2 -

E Steel plate form m2 -

F Load Cell nos -

94.5 METALS
CARRIED TO SUMMARY AT END OF BILL NO. 94 Rp. -

TA2459 Lesaffre Garuda 11/24 72ae-1b3b-55d9-5dc4-2.5


Item BILL NO. 94 94.5 METALS
Qty. Unit Rate Rupiahs
No GUARD HOUSE

TA2459 Lesaffre Garuda 12/24 72ae-1b3b-55d9-5dc4-2.5


Item BILL NO. 94 94.7 THERMAL AND MOISTURE Qty Unit Rate Rupiahs
No. GUARD HOUSE PROTECTION

94.7.1 ROOF SPECIALITIES

Supply and Install down pipe complete with overflow, steel clamp, support,
fitting, bracket, steel unp, and all fixing accessories; all in accordance with
drawings and specifications

A PVC Downpipe Ø4" m -

B Cast Iron Drain Strainer no -

Supply and install rubberized asphalt sheet, extrude polystyrene boar 30mm
thick, PU separation sheet, screed all in accordance with manufacturer's
recommendations, drawings and specifications

C To Concrete Roof m2 -

94.7.2 SUNDRIES

D Waterdrip 10mm as drawing and specification m -

E Balustrade strip as drawing and specification m -

94.7 THERMAL AND MOISTURE PROTECTION


CARRIED TO SUMMARY AT END OF BILL NO. 94 Rp. -

TA2459 Lesaffre Garuda 13/24 72ae-1b3b-55d9-5dc4-2.7


Item BILL NO. 94
94.8 DOORS AND WINDOWS Qty. Unit Rate Rupiahs
No. GUARD HOUSE

94.8.1 DOORS

Supply and install alumnium door including vision panel / louvre, frames,
hardwares, treshold, steel plate, and all fixing accessories and supports as
drawings and specifications

A 94.DP.001 Size 1000x2200 nos -

B 94.DP.002 Size 1000x2200 nos -

C 94.DQ.003 Size 1000x2200 nos -

D 94.DQ.004 Size 1000x2200 nos -

94.8.2 WINDOWS

Supply and install aluminium fix window complete with laminated


tempered glass + clear glass, hardwares, and all necessary components,
fixing, accessories as drawing and specification.

E 94.WA.004 nos -

F 94.WA.005 nos -

G 94.WB.002 nos -

H 94.WB.003 nos -

I 94.WC.001 nos -

J Breeze Block nos -

94.8 DOORS AND WINDOWS


CARRIED TO SUMMARY AT END OF BILL NO. 94 Rp. -

TA2459 Lesaffre Garuda 14/24 72ae-1b3b-55d9-5dc4-2.8


Item BILL NO. 94
94.9. FINISHES Qty. Unit Rate Rupiahs
No GUARD HOUSE

94.9.1 FLOOR FINISHES

Supply and install Homogenous Tile complete with screed, gape grouting
and all in accordance with manufactured instruction applied: all in
accordance with drawings and specifications

A To Guard House m2 -

B To Skirting m2 -

94.9.2 WALL FINISHES

Supply and install Homogenous Tile complete with screed, gape grouting
and all in accordance with manufactured instruction applied: all in
accordance with drawings and specifications

C To Toilet m2 -

Prepare smooth and apply waterbased acrylic emulsion paint finish, in


accordance with manufacturer's recommendations, as specified to face of :

D Applied to plastered autoclaved concrete walls (Internal Wall) m2 -

Prepare smooth and apply waterbased wethershield emulsion paint finish,


in accordance with manufacturer's recommendations, as specified to face of

E Applied to plastered autoclaved concrete walls (External Wall) m2 -

F Applied to parapet wall

Prepare smooth and apply skimcoat, in accordance with manufacturer's


recommendations, as drawing and specification

G To Exposed Concrete m2 -

94.9.3 CEILING FINISHES

Prepare smooth and apply waterbased acrylic emulsion paint finish, in


accordance with manufacturer's recommendations, as specified to face of :

H To Ceiling m2 -

94.9. FINISHES
CARRIED TO SUMMARY AT END OF BILL NO. 94 Rp. -

TA2459 Lesaffre Garuda 15/24 72ae-1b3b-55d9-5dc4-2.9


Item BILL NO. 94
94.10 SPECIALITIES Qty. Unit Rate Rupiahs
No GUARD HOUSE

94.10.1 INTERIOR SPECIALITIES

Supply and install sanitary wares complete with all necessary in


accordance with manufacturer's recommendations as drawing and

A SF8, Wall Mounted tap no -

B SF10, Toilet Seated no -

C SF11, Floor Drain no -

D SF12, Jet Shower no -

E SF17, Under Counter Lavatory no -

F SF19, Paper Towel Holder no -

G SF23, Mirror no -

H SF24, Soap Dispenser no -

94.10 SPECIALITIES
CARRIED TO SUMMARY AT END OF BILL NO. 94 Rp. -

TA2459 Lesaffre Garuda 16/24 72ae-1b3b-55d9-5dc4-2.10


Item BILL NO. 94
94.11 MECHANICAL WORKS Qty. Unit Rate Rupiahs
No GUARD HOUSE

94.11 MECHANICAL WORKS

94.11.1 DOMESTIC COLD WATER

DOMESTIC COLD WATER SYSTEM INSTALLATION


Supply and install Domestic Water pipes; PPR PN 10 including fittings (for 50
mm dia. Pipe or less) fixed in position complete with seals (for underground
pipe) supports, hangers, brackets, clamp, painting, and other necessary fixing
and jointing material in accordance to the technical specification and drawings,
as described;

PIPEWORKS

A 15mm diameter pipe m

B 20mm diameter pipe m

C 25mm diameter pipe m

D 32mm diameter pipe m

VALVE AND ANCILLARIES

E 25mm diameter gate valve no

F 32mm diameter gate valve no

G AAV; 25mm diameter no

94.11.2 SEWAGE AND WASTE WATER SYSTEM

SEWAGE AND WASTE WATER SYSTEM INSTALLATION


Supply and Install Waste water, Sewage water pipes and Venting pipes; PVC Class
AW 10 kg/m2 including fittings (for 50 mm dia. Pipe or less) fixed in position
complete with supports, hangers, brackets, clamp, painting, and other necessary
fixing and jointing material in accordance to the technical specification and
drawings, as described;

PIPEWORKS (SEWAGE AND WASTE)

H 50mm diameter pipe m

I 80mm diameter pipe m

J 100mm diameter pipe m

PIPEWORKS (VENTING)

K 40mm diameter pipe m

L 50mm diameter pipe m

FITTINGS

M Fitting 80mm diameter no

N Fitting 100mm diameter no

TA2459 Lesaffre Garuda 17/24 72ae-1b3b-55d9-5dc4-2.11


Item BILL NO. 94
94.11 MECHANICAL WORKS Qty. Unit Rate Rupiahs
No GUARD HOUSE

To Collection Rp. -

TA2459 Lesaffre Garuda 18/24 72ae-1b3b-55d9-5dc4-2.11


Item BILL NO. 94
94.11 MECHANICAL WORKS Qty. Unit Rate Rupiahs
No GUARD HOUSE

SEWAGE AND WASTE WATER SYSTEM INSTALLATION (Cont'd)


Supply and Install Waste water, Sewage water pipes and Venting pipes; PVC Class
AW 10 kg/m2 including fittings (for 50 mm dia. Pipe or less) fixed in position
complete with supports, hangers, brackets, clamp, painting, and other necessary
fixing and jointing material in accordance to the technical specification and
drawings, as described;

VALVE AND ANCILLARIES

A Ventcap 50mm diameter no

B Clean out 50mm diameter no

C Clean out 100mm diameter no

Supply and Install STP Biotech cap. 3m3/day c/w Blower for aeration system,
effluent pump and all of supporting accessories. STP Biotech made of FRP
material, influuent BOD= 200 mg/lt, Efluent BOD=30 mg/lt, c/w control box,
vent pipe etc.

D STP BIOTECH set

94.11.3 HYDRANT & SPRINKLER SYSTEM

VALVE AND ANCILLARIES

E Portable fire extinguisher with capacity 6 kg chemical powder ABC type. no

To Collection Rp. -

COLLECTION

Page 94.11 /1 -

Page 94.11 /2 -

94.11 MECHANICAL WORKS


CARRIED TO SUMMARY AT END OF BILL NO. 94 Rp. -

TA2459 Lesaffre Garuda 19/24 72ae-1b3b-55d9-5dc4-2.11


Item BILL NO. 94
94.12 ELECTRICAL WORKS Qty. Unit Rate Rupiahs
No GUARD HOUSE

94.12 ELECTRICAL WORKS

94.12.1 SUB DISTRIBUTION BOARDS


Supply, Install and Testing Commissioning the following Sub Distribution board
fix in position includes circuit breaker, board, busbar, digital multimeter,
contactor, surge arrester, potensial transformer, current transformer, indicator
lamp, fuse, loto, star / stop push button, and all necessary accessories in
arcondance to the technical spesification as shown on drawing, as described : -

A 94DB01 no

94.12.2 MAIN AND SUB-MAINS CABLES


Supply and Install the following Main and Sub-Mains circuit distribution cable
run & fixed on cable tray/ladders including all necessary accessories in
arcondance to the technical spesification as shown on drawing, as described : -

B From SDB…. to 94DB01 m by other package

94.12.3 LIGHTING FIXTURES & POWER OUTLET


Supply and Install the following light fittings including tubes or lamps fixed in
position complete with all accessories and support in accordance with the
technical specification and drawings, as described :-

C Recessed mounted TLED 40W, 220V, 3709 lm no

D Recessed mounted TLED 40W, 220V, 3709 lm, c/w nicad battery duration 1 no
hour

E Flood light LED 100W, 9500 lm no

F Downlight 16W, 220V, minimum 1200 lm no

G Downlight 16W, 220V, minimum 1200 lm, c/w nicad battery duration 1 hour no

Supply and Install the following switches including provision of steel/metal box
and all accessories accordance with the technical specification and drawings, as
described :-

H Single gang, 1 way switch, 10A no

I Double gang, 1 way switch, 10A no

Supply and Install lighting & switch cables from sub circuit to final circuit
including grounding system and all neccessary accessories accordance with the
technical specification and drawings, as described :-

J Cabling point from local panel (500V/CU/PVC 3C x 2.5 mm² shall be UV & no
chemical resistance) run-in and with PVC high impact conduit) to; lighting and
switch

To Collection Rp. -

TA2459 Lesaffre Garuda 20/24 72ae-1b3b-55d9-5dc4-2.12


Item BILL NO. 94
94.12 ELECTRICAL WORKS Qty. Unit Rate Rupiahs
No GUARD HOUSE

POWER OUTLET
Supply and Install the following power outlet including provision of steel/metal
box and all accessories accordance with the Technical Specification and
drawings, as described :-

A General socket outlet, wall mounted, 16A, 250V, single gang no

B General socket outlet, wall mounted, 16A, 250V, double gang no

94.12.4 TRAYS AND LADDERS


Supply and Install hot dip galvanized tray and ladder 2mm thickness include
jointing, elbow, tee, fixing accessories and hangers and all necessary accessories
accordance with the technical specification and drawings, as described :-

Electrical
C Cable tray 200x100mm m

Electronic
D Cable tray 100x100mm m

94.12.5 GROUNDING & LIGHTNING PROTECTION SYSTEM


Supply and Install Grounding system for panel and equipment complete with
support and all neccessary accessories accordance with the technical
specification and drawings, as described :-

E Earth pit, Conductor clamp and rod electrode, dia 19mm x 3000 length no

F Earthing bonding bar (copper bar) 50x3mm thk, c/w isolator no

G BC 70mm2, grounding cable for main/mesh earthing c/w connector and m


grounding lug

H Bonding cable NYAF 16mm2 m

I Bonding cable NYAF 25mm2 m

J Bonding cable NYAF 35mm2 m

94.12.6 FIRE ALARM


Supply and Install the following Fire Alarm Equipment complete with support, and
all necessary accessories in accordance to the technical specification and
drawings, as described : -

K MCPFA no

L JBFA-94-01 no

M Addressable photoelectric smoke detector no

Supply and Install the following Fire Alarm cables in final sub-circuit to
termination, run-in and with steel conduit 20mm dia; including earthing system
and all necessary accessories in accordance to the technical spesification as
shown on drawing, as described : -

N Power Cable FRC 2Cx2,5 mm2; from BD40 m

To Collection Rp. -

TA2459 Lesaffre Garuda 21/24 72ae-1b3b-55d9-5dc4-2.12


Item BILL NO. 94
94.12 ELECTRICAL WORKS Qty. Unit Rate Rupiahs
No GUARD HOUSE

94.12.6 FIRE ALARM (Cont'd)


Supply and Install the following Fire Alarm cables in final sub-circuit to
termination, run-in and with steel conduit 20mm dia; including earthing system
and all necessary accessories in accordance to the technical spesification as
shown on drawing, as described : -

A Cable FRC STP 2Cx1,5 mm2; from BD40 m

B Cable FRC STP 2Cx1,5 mm2; for detector point no

94.12.7 PUBLIC ADDRESS


Supply and Install the following Sound System Equipment complete with support,
and all necessary accessories in accordance to the technical specification and
drawings, as described : -

C Wall mounted switch rack JBPA-94-01 (SR-94-01) no

D Indoor ceiling mounted speaker 6W no

E Horn speaker 15W no

Supply and Install the following Public Address cables in final sub-circuit to
termination, run-in and with steel conduit 20mm dia; including earthing system
and all necessary accessories in accordance to the technical spesification as
shown on drawing, as described : -

F Cable FO OM3; from BD96 m

G Cable NYMHY 2Cx1,5 mm2; for indor ceiling speaker point no

H Cable NYMHY 2Cx1,5 mm2; for horn speaker point no

94.12.8 DATA AND TELEPHONE


Supply and Install the following Data and Communication System
Equipment complete with support, and all necessary accessories in
accordance to the technical specification and drawings, as described : -

I Wall mounted switch rack SR-92-01 no

J Single gang type data outlet (RJ45) no

K Single gang type telephone outlet (RJ45) no

Supply and Install the following Data and Telephone cables in final sub-circuit
to termination, run-in and with steel conduit 20mm dia; including earthing system
and all necessary accessories in accordance to the technical spesification as
shown on drawing, as described : -

L Cable UTP-CAT6/FO mm2; for data outlet point no

M Cable UTP-CAT6/FO mm2; for data outlet point no

N Cable UTP-CAT6/FO mm2; for telephone outlet point no

O Cable FO OM3; from BD96 m

To Collection Rp. -

TA2459 Lesaffre Garuda 22/24 72ae-1b3b-55d9-5dc4-2.12


Item BILL NO. 94
94.12 ELECTRICAL WORKS Qty. Unit Rate Rupiahs
No GUARD HOUSE

94.12.9 SECURITY SYSTEM


Supply and Install the following Security System Equipment complete with
support, and all necessary accessories in accordance to the technical specification
and drawings, as described : -

A Wall mounted switch rack SR-94-01 no

B IP based bullet fix camera outdoor type no

C IP based dome camera no

D Acces control door consist of; no


Door control
Finger print / card reader
Push button door release

Supply and Install the following Security cables in final sub-circuit to


termination, run-in and with PVC conduit 25mm dia underground direct burried
min 500mm below grade or through pipe rack; including earthing system and all
necessary accessories in accordance to the technical spesification as shown on
drawing, as described : -

E Cable UTP-CAT6/FO; for bullet fix camera indoor type point no

F Cable UTP-CAT6/FO; for bullet dome camera no

G Cable UTP-CAT6/FO; for acces control door point no

H Cable FO OM3; from BD96 m

To Collection Rp. -

COLLECTIONS

Page 94.12 /1 -

Page 94.12 /2 -

Page 94.12 /3 -

Page 94.12 /4 -

94.12 ELECTRICAL WORKS


CARRIED TO SUMMARY AT END OF BILL NO. 94 Rp. -

TA2459 Lesaffre Garuda 23/24 72ae-1b3b-55d9-5dc4-2.12


Item BILL NO. 94
94.13 HVAC WORKS Qty. Unit Rate Rupiahs
No GUARD HOUSE

94.13 HVAC WORKS

94.13.1 EQUIPMENT

DX UNIT
Supply and Install of DX Units complete with hangers/supports, vibration
mountings, neoprene pads and all necessary accessories in accordance to
the technical specification and drawings, as described : -

A IU-DX.94.00.01A-B; wall mounted, cooling capacity 4kWth, supply no


air flow 564 CMH, 0.1kW, 220V/1Ph/50Hz

B OU-DX.94.00.01; air colled inverter, cooling capacity 7.9kWth, supply no


air flow 564 CMH, 1.5kW, 220V/1Ph/50Hz

FAN
Supply and Install of Fan Units complete with hangers/supports, vibration
mountings, neoprene pads and all necessary accessories in accordance to the
technical specification and drawings, as described : -

C Exhasut Fan EF-94.00.01, axial wall mounted, cap 105-314 CMH, axial wall no
mounted, static pressure 117.6 pa, 0.1kW, 380V/3Ph/50Hz

D Exhasut Fan EF-94.00.01, axial wall mounted, cap 143-314 CMH, axial wall no
mounted, static pressure 117.6 pa, 0.1kW, 380V/3Ph/50Hz

94.13.2 REFRIGERANT & DRAIN PIPES


Supply and install the following Refrigerant Copper Pipeworks including
FM Approved insulation ,vapour barrier, trap, fittings (for 50mm diameter
pipe or less), joints, flanges, support and all accessories in accordance to
the technical specification and drawings, as described : -

E 6.5 mm diameter pipe copper c/w insulation m

F 9,5 mm diameter pipe copper c/w insulation m

DRAIN PIPES
G 25 mm diameter pipe PVC Class AW c/w insulation m

94.13 HVAC WORKS


CARRIED TO SUMMARY AT END OF BILL NO. 94 Rp. -

TA2459 Lesaffre Garuda 24/24 72ae-1b3b-55d9-5dc4-2.13


BILL NO. 95
FIRE PUMP HOUSE

TA2459 Lesaffre Garuda 1/24 c3c8-17e2-26bb-8c60-Cover


Item BILL NO. 95 SUMMARY RUPIAHS
No. FIRE PUMP HOUSE

SUMMARY

95.1 DEMOLITION N/A

95.2 EARTHWORK -

95.3 CONCRETE -

95.4 MASONRY -

95.5 METALS -

95.7 THERMAL AND MOISTURE PROTECTION -

95.8 DOORS AND WINDOWS -

95.9. FINISHES -

95.10 SPECIALITIES N/A

95.11 MECHANICAL WORKS -

95.2 ELECTRICAL WORKS -

95.3 HVAC WORKS N/A

BILL NO. 95
CARRIED TO SUMMARY -

TA2459 Lesaffre Garuda 2/24 c3c8-17e2-26bb-8c60-Sum


Item BILL NO. 95 Qty Unit Rate Rupiahs
95.2 EARTHWORK
No. FIRE PUMP HOUSE

95.2.1 EARTHWORK

Excavation, disposal and backfill in any material including rock or hard


material, working space at parimeter items as defined; Excavating, starting
from stripped level, trenches to receive depth as pecified (insite area)

A To Footings m3

B To Slab incl. ramp m3

C To Tie Beam m3

D To Column m3

95.2.2 BASE COURSES

Compacted of subgrade to 95% Standard Proctor Density as specified

E To Footings m2

F To Slab incl. ramp m2

G To Tie Beam m2

Sandfill 100mm thick as specified

H To Footings m2

I To Slab m2

J To Tie Beam m2

Compacted gravel 200mm thick as specified

K To Under Ramp and Perimeter m2

95.2.3 TERMITE CONTROL

Termite control to soil; The protection against termites by spraying an


insecticide on the soil or on the fill before placing the vapor and after
building completed and importing landfill; undertaken by an approved
specialist; (5 years quarantee to be given) as specified.

L To Footings m2

M To Slab incl. ramp m2

N To Tie Beam m2

O To Column m2

TA2459 Lesaffre Garuda 3/24 c3c8-17e2-26bb-8c60-2.2


Item BILL NO. 95 Qty Unit Rate Rupiahs
95.2 EARTHWORK
No. FIRE PUMP HOUSE

To Collection Rp. -

95.2.4 OTHERS

Plastic sheet

A To Footings m2

B To Perimeter Slab m2

C To Tie Beam m2

To Collection Rp. -

COLLECTIONS

Page 95.2/1 -

Page 95.2/2 -

95.2 EARTHWORK

TA2459 Lesaffre Garuda 4/24 c3c8-17e2-26bb-8c60-2.2


Item BILL NO. 95 Qty Unit Rate Rupiahs
95.2 EARTHWORK
No. FIRE PUMP HOUSE

CARRIED TO SUMMARY AT END OF BILL NO. 95 Rp. -

TA2459 Lesaffre Garuda 5/24 c3c8-17e2-26bb-8c60-2.2


Item BILL NO. 95
95.3 CONCRETE Qty. Unit Rate Rupiahs
No. FIRE PUMP HOUSE

95.3.1 FORMWORK

95.3.1.1 IN GROUND FORMWORK

The design, certification, construction and performance of the formwork,


falsework and backpropping shall be the responsibilty of Contractor.
Proposed method of installation and removal of formwork is to be
submitted to the Superintendent for comment prior to work being carried
out as per dwg note.
In ground formwork as follows; permanent formwork system for in-place
concrete, concrete hollow block 100mm thick, finish starting at/from any
level and including rebates or grooves formers as described to

A To Footings m2 -

B To Slab Incl. Ramp m2 -

C To Tie Beam m2 -

95.3.1.2 UPPER STRUCTURE FORMWORK

Smooth-Formed Finished concrete, plywood, metal, or other approved


panel materials, finish starting at/from any level and rebates or groove
formers as specified

D To Beam m2 -

E To Column m2 -

F To Gutter m2 -

G To Wall m2 -

H To Plinths m2 -

95.3.2 CONCRETE

In-Situ Concrete

In-situ concrete designed mix Grade 30 Mpa, (K-350) NFA; ± 20mm


aggregate, vibrated with standard flatness as described ;

I To Footings m3 -

J To Slab Incl. Ramp m3 -

K To Tie Beam and Upper Beam m3 -

L To Pedestal and Column m3 -

M To Wall m3 -

N To Plinths m3 -

TA2459 Lesaffre Garuda 6/24 c3c8-17e2-26bb-8c60-2.3


Item BILL NO. 95
95.3 CONCRETE Qty. Unit Rate Rupiahs
No. FIRE PUMP HOUSE

To Collection Rp. -

95.3.2 CONCRETE, CONT'D

Lean Concrete

Plain in-situ concrete, designed mix grade f'c= Mpa,(K-125), 40mm


aggregate, 50mm thick as described,

A To Footings m2 -

B To Slab Incl. Ramp m2 -

C To Tie Beam m2 -

95.3.3 REINFORCEMENT

Manufacture reinforcement bars is according to "Manual of Standard


Practice" CRSI's as follows; supply, cleaned, measurement, positioning,
setting and install. Reinforcement measure include joint dowel bars,
bolsters, chairs, spacers and other device for spacing, supporting and
fastening reinforcing bars and welded wire reinforcement in place.

Reinforcing bars is Grade 60/420 deformed or Grade BJTD 40 deformed.


round mild steel, as described in

D Dia. 13mm, To Footings kg -

E Dia. 13mm To Slab Incl. Ramp kg -

F Dia. 10mm To Slab Incl. Ramp kg -

G Dia. 19mm, To Tie Beam and Upper Beam kg -

H Dia. 13mm, To Tie Beam and Upper Beam kg -

I Dia. 10mm, To Tie Beam and Upper Beam kg -

J Dia. 16mm, To Pedestal and Column kg -

K Dia. 10mm, To Pedestal and Column kg -

L Dia. 10mm, To Wall kg -

M Dia. 10mm, To Plinths kg -

N Dia. 8mm, To Plinths kg -

95.3.4 SUNDRIES

O Supply and install steel galvanized grating 40mm thick including steel m2
angle, plate and all necessary per drawings and specifications (Cover

P Supply and install polystirene 5mm thick replace by flexible joint, dowel m
16mm (round bar) ctc 300, L=300mm one side coated with bitumen per
darings and specifications

Q Anchors bolt dia. 10mm to plinths nos

TA2459 Lesaffre Garuda 7/24 c3c8-17e2-26bb-8c60-2.3


Item BILL NO. 95
95.3 CONCRETE Qty. Unit Rate Rupiahs
No. FIRE PUMP HOUSE

To Collection Rp. -

COLLECTIONS

Page 95.3 /1 -

Page 95.3 /2 -

TA2459 Lesaffre Garuda 8/24 c3c8-17e2-26bb-8c60-2.3


Item BILL NO. 95
95.3 CONCRETE Qty. Unit Rate Rupiahs
No. FIRE PUMP HOUSE

95.3 CONCRETE
CARRIED TO SUMMARY AT END OF BILL NO. 95 Rp. -

TA2459 Lesaffre Garuda 9/24 c3c8-17e2-26bb-8c60-2.3


Item BILL NO. 95
95.4 MASONRY Qty. Unit Rate Rupiahs
No FIRE PUMP HOUSE

95.4.1 UNIT MASONRY

Supply and Install Autoclaved aerated concrete block wall with mortar;
including reinforced concrete bonding ties, anchorage, latching, stiffener
columns and lintels beams as required, all in accordancce with drawings
and specifications
A To Wall 150mm thick External Wall m2 -

95.4.2 PLASTERED

Plaster; Mortar instant trowelled smooth with and including cement coating
instant as described

B To Wall 150mm thick m2 -

95.4 MASONRY
CARRIED TO SUMMARY AT END OF BILL NO. 95 Rp. -

TA2459 Lesaffre Garuda 10/24 c3c8-17e2-26bb-8c60-2.4


Item BILL NO. 95 95.5 METALS
Qty. Unit Rate Rupiahs
No FIRE PUMP HOUSE

95.5.1 STRUCTURAL FRAMING

The following in steel structure in framing sanblasting and painting


finished ; from ground level to roof floor level; comprising wide flange
bolted to mild steel, cleats, welded to rafter; including all labour,
materials and plant in fabricating,erecting with welded and bolted shop
and site connections; assembling and erecting with welded and bolted
shop and site connections; and all necessaries as specified on
specification and drawing; steel grade as note on specifications ( ASTM
A-36 / BJ 37 for steel structure)
A SC4, WF200x200x8x12 kg -

B HB17, Dia16-HB kg -

C PR5, C200x75x20x2.3 kg -

D R1, WF150x75x5x7-R kg -

E R2, WF250x125x6x9-R kg -

F R3, WF300x150x6.5x9-R kg -

G SB1A, WF100x50x5x7-SB kg -

H SB2, WF200x100x5.5x8-SB kg -

I SB21B, C100x50x20x2.3-SB kg -

J SG1, WF150x75x5x7-SG kg -

K SG2, WF200x100x5.5x8-SG kg -

L TR2, Dia12-TR kg -

M All connecting plates, brackets, cleats, bolts, anchor bolts and stiffeners, Ls -
welding, including sandblasting and painted finish and all necessary
fixing accessories as described

95.5 METALS
CARRIED TO SUMMARY AT END OF BILL NO. 95 Rp. -

TA2459 Lesaffre Garuda 11/24 c3c8-17e2-26bb-8c60-2.5


Item BILL NO. 95 95.5 METALS
Qty. Unit Rate Rupiahs
No FIRE PUMP HOUSE

TA2459 Lesaffre Garuda 12/24 c3c8-17e2-26bb-8c60-2.5


Item BILL NO. 95 95.7 THERMAL AND MOISTURE Qty Unit Rate Rupiahs
No. FIRE PUMP HOUSE PROTECTION

95.7.1 FLASHING AND SHEET METAL

Supply and Install metal roof Klip Lok Optima 0.45 BMT fixed to steel
purlin including flashing, sealant, and all fixing accessories; all in
accordance with drawings and specifications

A To Roof m2 -

Supply and Install Waterstop Colorbond finish fixed to metal roof sheet,
including sealant and all necessary fixing accessories; all in accordance with
drawings and specifications

B To Roof m -

Supply and Install Metal cladding Trimdek 0.45 BMT finish colorbond
fixed to steel structure, including sealant, over flow galvanized steel pipe
Ø2" 6000mm CTC, and all necessary fixing accessories; all in accordance
with drawings and specifications

C To Fascia m2 -

Supply and Install Metal Flashing 0.45 BMT finish colorbond fixed to steel
purlin, including sealant and all necessary fixing accessories; all in
accordance with drawings and specifications

D To Roof m -

95.7.2 ROOF SPECIALITIES

Supply and Install metal gutter 0.5mm with weatherproof sealant complete
with plate support, jointing and all necessary fixing accessories and support,
in accordance with manufacturer's recommendations, as drawings and
specifications

E To Roof Gutter m2 -

Supply and Install down pipe complete with overflow, steel clamp, support,
fitting, bracket, steel unp, and all fixing accessories; all in accordance with
drawings and specifications

F PVC Downpipe Ø4" m -

G Chromium roof drain strainer nos -

95.7 THERMAL AND MOISTURE PROTECTION

TA2459 Lesaffre Garuda 13/24 c3c8-17e2-26bb-8c60-2.7


Item BILL NO. 95 95.7 THERMAL AND MOISTURE Qty Unit Rate Rupiahs
No. FIRE PUMP HOUSE PROTECTION
CARRIED TO SUMMARY AT END OF BILL NO. 95 Rp. -

TA2459 Lesaffre Garuda 14/24 c3c8-17e2-26bb-8c60-2.7


Item BILL NO. 95
95.8 DOORS AND WINDOWS Qty. Unit Rate Rupiahs
No. FIRE PUMP HOUSE

95.8.1 DOORS

Supply and install steel doors including frames, hardwares, treshold, steel
plate, and all necessary accessories and fixing supports as drawings and

A 95.DG.001 nos -

95.8.2 LOUVRES

Supply and install steel louvre complete with removable insect screen,
hardwares, and all necessary components, fixing, accessories as drawing

B 95.LA.001 nos -

C 95.LA.002 nos -

D 95.LA.003 nos -

E 95.LA.004 nos -

F 95.LA.005 nos -

95.8 DOORS AND WINDOWS


CARRIED TO SUMMARY AT END OF BILL NO. 95 Rp. -

TA2459 Lesaffre Garuda 15/24 c3c8-17e2-26bb-8c60-2.8


Item BILL NO. 95
95.8 DOORS AND WINDOWS Qty. Unit Rate Rupiahs
No. FIRE PUMP HOUSE

TA2459 Lesaffre Garuda 16/24 c3c8-17e2-26bb-8c60-2.8


Item BILL NO. 95
95.9. FINISHES Qty. Unit Rate Rupiahs
No FIRE PUMP HOUSE

95.9.1 FLOOR FINISHES

Supply and install floor hardener including all necessary per drawings and
specifications

A To Floor m2 -

B Skirting, PU paint m -

95.9. FINISHES
CARRIED TO SUMMARY AT END OF BILL NO. 95 Rp. -

TA2459 Lesaffre Garuda 17/24 c3c8-17e2-26bb-8c60-2.9


Item BILL NO. 95
95.10 SPECIALITIES Qty. Unit Rate Rupiahs
No FIRE PUMP HOUSE

95.10 SPECIALITIES
CARRIED TO SUMMARY AT END OF BILL NO. 95 Rp. N/A

TA2459 Lesaffre Garuda 18/24 c3c8-17e2-26bb-8c60-2.10


Item BILL NO. 95
95.11 MECHANICAL WORKS Qty. Unit Rate Rupiahs
No FIRE PUMP HOUSE

95.11 MECHANICAL WORKS

95.11.1 EQUIPMENT
Supply and Install of following main equipment plumbing including control panel,
valve, supporting frame, connection, fixing, testing, commissioning and all
necessary accessories in arcondance to the technical spesification as shown on
drawing, as described : -

A Main Electrical Fire Pump, NFPA-20 and UL/FM listed with capacity 2000 no
GPM, 10 Bar (150 psi), power 336 BHP (MP-01)

B Diesel Engine fire Pump, NFPA-20 and UL/FM listed with capacity 2000 GPM, no
12 Bar (175 psi), power 336 BHP (MP-02)

C Jockey pump, in line centrifugal type with capacity 50 GPM, 13 Bar (185 psi), no
power 8 kw / 380 v / 50 Hz

D Daily fuel tank capacity 515 gallons complete with spill protection and all set
accessories needed.

95.11.2 PUMP ROOM INSTALLATION


Supply and install Sprinkler pipes, Black steel pipe to ASTM A 53 schedule 40 ,
Grade B, including fitting (for 50 mm dia. Pipe or less) fixed in position complete
with supports, hangers, brackets, clamp, painting, and other necessary fixing and
jointing material in accordance to the technical specification and drawings, as
described;

PIPEWORKS

E 300mm diameter header pipe c/w flange, connection and accessories no

F 250mm diameter header pipe c/w flange, connection and accessories m

G 300mm diameter pipe m

H 200mm diameter pipe m

I 150mm diameter pipe m

J 65mm diameter pipe m

K 25mm diameter pipe m

FITTINGS

L Fitting 300mm diameter no

M Fitting 200mm diameter no

N Fitting 150mm diameter no

O Fitting 65mm diameter no

To Collection Rp. -

TA2459 Lesaffre Garuda 19/24 c3c8-17e2-26bb-8c60-2.11


Item BILL NO. 95
95.11 MECHANICAL WORKS Qty. Unit Rate Rupiahs
No FIRE PUMP HOUSE

95.11.2 PUMP ROOM INSTALLATION (Cont'd)


Supply and install Sprinkler pipes, Black steel pipe to ASTM A 53 schedule 40 ,
Grade B, including fitting (for 50 mm dia. Pipe or less) fixed in position complete
with supports, hangers, brackets, clamp, painting, and other necessary fixing and
jointing material in accordance to the technical specification and drawings, as
described;

VALVE AND ANCILLARIES

A Gate valve; 250mm diameter, UL listed & FM approved no

B Gate valve; 80mm diameter, UL listed & FM approved no

C Gate valve; 65mm diameter, UL listed & FM approved no

D Gate valve; 250mm diameter no

E Gate valve; 80mm diameter no

F Gate valve; 65mm diameter no

G Flexible joint; 250mm diameter no

H Flexible joint; 80mm diameter no

I Flexible joint; 65mm diameter no

J Flow meter; 200mm diameter no

K Vortex inhibitor; 250mm diameter no

L Pressure relief valve; 250mm diameter no

M AAV; 25mm diameter no

N Pressure release valve; 250mm diameter no

O Pressure gauge c/w valve no

ASSOCIATED ELECTRICAL WORK

P Distribution board, PP-Fire electric pump no

Q Distribution board, PP-Fire diesel pump no

R Distribution board, PP-Jockey pump no

S Cabling for jockey pump no

T Cabling for electric fire pump no

U Cabling for diesel fire pump no

To Collection Rp. -

TA2459 Lesaffre Garuda 20/24 c3c8-17e2-26bb-8c60-2.11


Item BILL NO. 95
95.11 MECHANICAL WORKS Qty. Unit Rate Rupiahs
No FIRE PUMP HOUSE

COLLECTIONS

Page 95.11 /1 -

Page 95.11 /2 -

95.11 MECHANICAL WORKS


CARRIED TO SUMMARY AT END OF BILL NO. 95 Rp. -

TA2459 Lesaffre Garuda 21/24 c3c8-17e2-26bb-8c60-2.11


Item BILL NO. 95
95.2 ELECTRICAL WORKS Qty. Unit Rate Rupiahs
No FIRE PUMP HOUSE

95.12 ELECTRICAL WORKS

95.12.1 SUB DISTRIBUTION BOARDS


Supply, Install and Testing Commissioning the following Sub Distribution board
fix in position includes circuit breaker, board, busbar, digital multimeter,
contactor, surge arrester, potensial transformer, current transformer, indicator
lamp, fuse, loto, star / stop push button, and all necessary accessories in
arcondance to the technical spesification as shown on drawing, as described : -

A 95DB01 no

95.12.2 MAIN AND SUB-MAINS CABLES


Supply and Install the following Main and Sub-Mains circuit distribution cable
run & fixed on cable tray/ladders including all necessary accessories in
arcondance to the technical spesification as shown on drawing, as described : -

B From SDB…. to 95DB01 m by other package

95.12.3 LIGHTING FIXTURES & POWER OUTLET


Supply and Install the following light fittings including tubes or lamps fixed in
position complete with all accessories and support in accordance with the
technical specification and drawings, as described :-

C High bay LED 75W, 10503 lm, 220V, surface mounted no

D High bay LED 75W, 10503 lm, 220V, surface mounted, c/w nicad battery no
duration 1 hour

E Waterproof LED 20W, 220V, IP65, 2000 lm, L600 no

F Waterproof LED 20W, 220V, IP65, 2000 lm, L600, c/w nicad battery duration 1 no
hour

Supply and Install the following switches including provision of steel/metal box
and all accessories accordance with the technical specification and drawings, as
described :-

G Double gang, 1 way switch, 10A no

Supply and Install lighting & switch cables from sub circuit to final circuit
including grounding system and all neccessary accessories accordance with the
technical specification and drawings, as described :-

H Cabling point from local panel (500V/CU/PVC 3C x 2.5 mm² shall be UV & no
chemical resistance) run-in and with PVC high impact conduit) to; lighting and
switch

POWER OUTLET
Supply and Install the following power outlet including provision of steel/metal
box and all accessories accordance with the Technical Specification and
drawings, as described :-

I General socket outlet c/w cover, wall mounted, 16A, 250V, single gang no

J General socket outlet c/w cover, wall mounted, 16A, 250V, double gang no

To Collection Rp. -

TA2459 Lesaffre Garuda 22/24 c3c8-17e2-26bb-8c60-2.12


Item BILL NO. 95
95.2 ELECTRICAL WORKS Qty. Unit Rate Rupiahs
No FIRE PUMP HOUSE

95.12.4 TRAYS AND LADDERS


Supply and Install hot dip galvanized tray and ladder 2mm thickness include
jointing, elbow, tee, fixing accessories and hangers and all necessary accessories
accordance with the technical specification and drawings, as described :-

Electrical
A Cable ladder 600x100mm m

B Cable tray 300x100mm m

95.12.5 GROUNDING & LIGHTNING PROTECTION SYSTEM


Supply and Install Grounding system for panel and equipment complete with
support and all neccessary accessories accordance with the technical
specification and drawings, as described :-

C Earth pit, Conductor clamp and rod electrode, dia 19mm x 3000 length no

D Earthing bonding bar (copper bar) 50x3mm thk, c/w isolator no

E BC 70mm2, grounding cable for main/mesh earthing c/w connector and m


grounding lug

F Bonding cable NYAF 16mm2 m

G Bonding cable NYAF 25mm2 m

H Bonding cable NYAF 35mm2 m

95.12.6 FIRE ALARM


Supply and Install the following Fire Alarm Equipment complete with support, and
all necessary accessories in accordance to the technical specification and
drawings, as described : -

I Addressable photoelectric smoke detector no

Supply and Install the following Fire Alarm cables in final sub-circuit to
termination, run-in and with steel conduit 20mm dia; including earthing system
and all necessary accessories in accordance to the technical spesification as
shown on drawing, as described : -

J Cable FRC STP 2Cx1,5 mm2; for detector point no

To Collection Rp. -

COLLECTIONS

Page 95.12 /1 -

Page 95.12 /2 -

95.2 ELECTRICAL WORKS


CARRIED TO SUMMARY AT END OF BILL NO. 95 Rp. -

TA2459 Lesaffre Garuda 23/24 c3c8-17e2-26bb-8c60-2.12


Item BILL NO. 95
95.3 HVAC WORKS Qty. Unit Rate Rupiahs
No FIRE PUMP HOUSE

95.3 HVAC WORKS


CARRIED TO SUMMARY AT END OF BILL NO. 95 Rp. N/A

TA2459 Lesaffre Garuda 24/24 c3c8-17e2-26bb-8c60-2.13


BILL NO. 96
ADMINISTRATION BUILDING

TA2459 Lesaffre Garuda 1/65 4788-3e5a-e0c9-5708-Cover


Item BILL NO. 96 SUMMARY RUPIAHS
No. ADMINISTRATION BUILDING

SUMMARY

96.1 DEMOLITION N/A

96.2 EARTHWORK -

96.3 CONCRETE -

96.4 MASONRY -

96.5 METALS -

96.7 THERMAL AND MOISTURE PROTECTION -

96.8 DOORS AND WINDOWS -

96.9. FINISHES -

96.10 SPECIALITIES -

96.11 MECHANICAL WORKS -

96.12 ELECTRICAL WORKS -

96.13 HVAC WORKS -

BILL NO. 96
CARRIED TO SUMMARY -

TA2459 Lesaffre Garuda 2/65 4788-3e5a-e0c9-5708-Sum


Item BILL NO. 96 Qty Unit Rate Rupiahs
96.2 EARTHWORK
No. ADMINISTRATION BUILDING

96.2.1 CUT OFF PILE HEAD

Cut off pile head as drawings

A Spun pile, dia. 400mm nos

96.2.2 EARTHWORK

Excavation, disposal and backfill in any material including rock or hard


material, working space at parimeter items as defined; Excavating, starting
from stripped level, trenches to receive depth as pecified (insite area)

B To Footings and Pile Caps m3

C To Slab incl. ramp m3

D To Tie Beam m3

E To Pedestal m3

96.2.3 BASE COURSES

Compacted of subgrade to 95% Standard Proctor Density as specified

F To Footings and Pile Caps m2

G To Slab incl. ramp m2

H To Tie Beam m2

Sandfill 100mm thick as specified

I To Footings and Pile Caps m2

J To Slab m2

K To Tie Beam m2

Compacted gravel 200mm thick as specified

L To Under Ramp and Perimeter m2

96.2.4 TERMITE CONTROL

Termite control to soil; The protection against termites by spraying an


insecticide on the soil or on the fill before placing the vapor and after
building completed and importing landfill; undertaken by an approved
specialist; (5 years quarantee to be given) as specified.

M To Footings and Pile Caps m2

N To Slab incl. ramp m2

O To Tie Beam m2

P To Pedestal m2

TA2459 Lesaffre Garuda 3/65 4788-3e5a-e0c9-5708-2.2


Item BILL NO. 96 Qty Unit Rate Rupiahs
96.2 EARTHWORK
No. ADMINISTRATION BUILDING

To Collection Rp. -

96.2.5 OTHERS

Plastic sheet

A To Footings and Pile Caps m2

B To Perimeter Slab m2

C To Tie Beam m2

To Collection Rp. -

COLLECTIONS

Page 96.2/1 -

Page 96.2/2 -

TA2459 Lesaffre Garuda 4/65 4788-3e5a-e0c9-5708-2.2


Item BILL NO. 96 Qty Unit Rate Rupiahs
96.2 EARTHWORK
No. ADMINISTRATION BUILDING

96.2 EARTHWORK
CARRIED TO SUMMARY AT END OF BILL NO. 96 Rp. -

TA2459 Lesaffre Garuda 5/65 4788-3e5a-e0c9-5708-2.2


Item BILL NO. 96
96.3 CONCRETE Qty. Unit Rate Rupiahs
No. ADMINISTRATION BUILDING

96.3.1 FORMWORK

96.3.1.1 IN GROUND FORMWORK

The design, certification, construction and performance of the formwork,


falsework and backpropping shall be the responsibilty of Contractor.
Proposed method of installation and removal of formwork is to be
submitted to the Superintendent for comment prior to work being carried
out as per dwg note.
In ground formwork as follows; permanent formwork system for in-place
concrete, concrete hollow block 100mm thick, finish starting at/from any
level and including rebates or grooves formers as described to

A To Footings and Pile Caps m2 -

B To Slab Incl. Ramp m2 -

C To Tie Beam m2 -

96.3.1.2 UPPER STRUCTURE FORMWORK

Smooth-Formed Finished concrete, plywood, metal, or other approved


panel materials, finish starting at/from any level and rebates or groove
formers as specified

D To Upper Slab m2 -

E To Beam m2 -

F To Pedestal and Column m2 -

G To Gutter m2 -

H To Wall/Parapet m2 -

I To Stairs m2 -

96.3.2 CONCRETE

In-Situ Concrete

In-situ concrete designed mix Grade 30 Mpa, (K-350) NFA; ± 20mm


aggregate, vibrated with standard flatness as described ;

J To Footings and Pile Caps m3 -

K To Ground and Upper Slab Incl. Ramp m3 -

L To Tie Beam and Upper Beam m3 -

M To Pedestal and Column m3 -

N To Wall/Parapet m3 -

O To Stairs m3 -

TA2459 Lesaffre Garuda 6/65 4788-3e5a-e0c9-5708-2.3


Item BILL NO. 96
96.3 CONCRETE Qty. Unit Rate Rupiahs
No. ADMINISTRATION BUILDING

To Collection Rp. -

96.3.2 CONCRETE, CONT'D

Lean Concrete

Plain in-situ concrete, designed mix grade f'c= Mpa,(K-125), 40mm


aggregate, 50mm thick as described,

A To Footings and Pile Caps m2 -

B To Slab Incl. Ramp m2 -

C To Tie Beam m2 -

96.3.3 REINFORCEMENT

Manufacture reinforcement bars is according to "Manual of Standard


Practice" CRSI's as follows; supply, cleaned, measurement, positioning,
setting and install. Reinforcement measure include joint dowel bars,
bolsters, chairs, spacers and other device for spacing, supporting and
fastening reinforcing bars and welded wire reinforcement in place.

Reinforcing bars is Grade 60/420 deformed or Grade BJTD 40 deformed.


round mild steel, as described in

D Dia. ..mm, To Footings and Pile Caps kg -

E Dia. ..mm, To Footings and Pile Caps kg -

F Dia. 10mm To Slab Incl. Ramp kg -

G Dia. 19mm, To Tie Beam and Upper Beam kg -

G Dia. 16mm, To Tie Beam and Upper Beam kg -

H Dia. 13mm, To Tie Beam and Upper Beam kg -

I Dia. 10mm, To Tie Beam and Upper Beam kg -

J Dia. 19mm, To Pedestal and Column kg -

J Dia. 16mm, To Pedestal and Column kg -

K Dia. 10mm, To Pedestal and Column kg -

L Dia. ..mm, To Wall/Parapet kg -

L Dia. ..mm, To Wall/Parapet kg -

M Dia. ..mm, To Stairs kg -

N Dia. ..mm, To Stairs kg -

96.3.4 SUNDRIES

TA2459 Lesaffre Garuda 7/65 4788-3e5a-e0c9-5708-2.3


Item BILL NO. 96
96.3 CONCRETE Qty. Unit Rate Rupiahs
No. ADMINISTRATION BUILDING

To Collection Rp. -

COLLECTIONS

Page 96.3 /1 -

Page 96.3 /2 -

TA2459 Lesaffre Garuda 8/65 4788-3e5a-e0c9-5708-2.3


Item BILL NO. 96
96.3 CONCRETE Qty. Unit Rate Rupiahs
No. ADMINISTRATION BUILDING

96.3 CONCRETE
CARRIED TO SUMMARY AT END OF BILL NO. 96 Rp. -

TA2459 Lesaffre Garuda 9/65 4788-3e5a-e0c9-5708-2.3


Item BILL NO. 96
96.4 MASONRY Qty. Unit Rate Rupiahs
No ADMINISTRATION BUILDING

96.4.1 UNIT MASONRY

Supply and Install Autoclaved aerated concrete block wall with mortar;
including reinforced concrete bonding ties, anchorage, latching, stiffener
columns and lintels beams as required, all in accordancce with drawings
and specifications
A To Wall 150mm thick External Wall m2 -

B To Wall 150mm thick Internal Wall m2 -

96.4.2 PLASTERED

Plaster; Mortar instant trowelled smooth with and including cement coating
instant as described

C To Wall 150mm thick m2 -

96.4.3 WALL PARTITION

Supply and install gypsum board including frames, support and all
necessary in accordance with manufacturer's recommendations, as specified

D To Wall m2 -

96.4.3 CEILING PARTITION

Supply and install calsium silicate board 6mm glued in gypsum ceiling
including ceiling suspension system and fixing accessories all in accordance
with drawings and specifications

E To Ceiling m2 -

Supply and Install Grid system with accoustic tile complete with metal stud
framing hanger and all necessary accessories and support; all in
accordancce with drawings and specifications

F To Ceiling m2 -

96.4 MASONRY
CARRIED TO SUMMARY AT END OF BILL NO. 96 Rp. -

TA2459 Lesaffre Garuda 10/65 4788-3e5a-e0c9-5708-2.4


Item BILL NO. 96 96.5 METALS
Qty. Unit Rate Rupiahs
No ADMINISTRATION BUILDING

96.5.1 STRUCTURAL FRAMING

The following in steel structure in framing sanblasting and painting


finished ; from ground level to roof floor level; comprising wide flange
bolted to mild steel, cleats, welded to rafter; including all labour,
materials and plant in fabricating,erecting with welded and bolted shop
and site connections; assembling and erecting with welded and bolted
shop and site connections; and all necessaries as specified on
specification and drawing; steel grade as note on specifications ( ASTM
A-36 / BJ 37 for steel structure)
A R2, WF200x100x5.5x8 kg -

B R3, WF250x125x6x9 kg -

C SB2, WF200x100x5.5x8 kg -

D SB13, UNP200x80x7.5x11 kg -

E SB21, SP kg -

F SG13, UNP200x80x7.5x11 kg -

G All connecting plates, brackets, cleats, bolts, anchor bolts and stiffeners, Ls -
welding, including sandblasting and painted finish and all necessary
fixing accessories as described

96.5.2 RAILING

Supply and Install steel pipe railing including handrail support and knee
railing complete with kick plate, anchor bolt and all necessary fixing
accessories as drawings and specifications

H To staircase m -

96.7.3 OTHERS

I Supply and install galvanized steel grating 32mm thick including all m2 -
support and accessories per drawings and specifications

96.5 METALS

TA2459 Lesaffre Garuda 11/65 4788-3e5a-e0c9-5708-2.5


Item BILL NO. 96 96.5 METALS
Qty. Unit Rate Rupiahs
No ADMINISTRATION BUILDING

CARRIED TO SUMMARY AT END OF BILL NO. 96 Rp. -

TA2459 Lesaffre Garuda 12/65 4788-3e5a-e0c9-5708-2.5


Item BILL NO. 96 96.6 WOODS, PLASTICS AND Qty. Unit Rate
No ADMINISTRATION BUILDING COMPOSITE

96.6.1 ALUMINIUM COMPOSITE PANEL

Supply and install aluminium composite panel fire retardant core including
steel support, aluminium support, hollow support, framing, sealant, other
jointing system, and all fixing accessories as drawings and specifications

A To Cover Perimeter Beam, 2nd Floor m2

B To Cover Perimeter Roof m2

C To Canopy Ceiling m2

TA2252 MBI SA 13/65 4788-3e5a-e0c9-5708-2.6


Item BILL NO. 96 96.6 WOODS, PLASTICS AND Qty. Unit Rate
No ADMINISTRATION BUILDING COMPOSITE
96.6 WOODS, PLASTICS AND COMPOSITE
CARRIED TO SUMMARY AT END OF BILL NO. 96 Rp.

TA2252 MBI SA 14/65 4788-3e5a-e0c9-5708-2.6


Rupiahs

TA2252 MBI SA 15/65 4788-3e5a-e0c9-5708-2.6


Rupiahs

TA2252 MBI SA 16/65 4788-3e5a-e0c9-5708-2.6


Item BILL NO. 96 96.7 THERMAL AND MOISTURE Qty Unit Rate Rupiahs
No. ADMINISTRATION BUILDING PROTECTION

91.7.1 ROOF SPECIALITIES

Supply and Install metal roof Klip Lok Optima 0.45 BMT finish fixed to
steel purlin including flashing, sealant, and all fixing accessories; all in
accordance with drawings and specifications

A To Canopy m2 -

96.7.2 ROOF SPECIALITIES

Supply and Install down pipe complete with overflow, steel clamp, support,
fitting, bracket, steel unp, and all fixing accessories; all in accordance with
drawings and specifications

B PVC Downpipe Ø4" m -

C Cast iron roof drain nos -

Supply and install concrete waterproofing liquid membrane complete with


accessories and support; all in accordance with manufacturer's instruction,
drawings, and specifications

D To Roof m2 -

Supply and install waterproofing membrane polyurethane complete with


accessories and support; all in accordance with manufacturer's instruction,
drawings, and specifications

E To Roof m2 -

TA2459 Lesaffre Garuda 17/65 4788-3e5a-e0c9-5708-2.7


Item BILL NO. 96 96.7 THERMAL AND MOISTURE Qty Unit Rate Rupiahs
No. ADMINISTRATION BUILDING PROTECTION
96.7 THERMAL AND MOISTURE PROTECTION
CARRIED TO SUMMARY AT END OF BILL NO. 96 Rp. -

TA2459 Lesaffre Garuda 18/65 4788-3e5a-e0c9-5708-2.7


Item BILL NO. 96
96.8 DOORS AND WINDOWS Qty. Unit Rate Rupiahs
No. ADMINISTRATION BUILDING

96.8.1 DOORS

Supply and install steel door including tempered and clear glass, frames,
hardwares, treshold, steel plate, and all fixing accessories and supports as
drawings and specifications

A 96.DH.002 nos -

Supply and install steel door including tempered and clear glass, vision
panel / louvre, frames, hardwares, treshold, steel plate, and all fixing
accessories and supports as drawings and specifications

B 96.DL.013 nos -

C 96.DL.014 nos -

D 96.DL.021 nos -

E 96.DL.039 nos -

Supply and install alumnium door including tempered and clear glass,
frames, hardwares, treshold, steel plate, and all fixing accessories and
supports as drawings and specifications

F 96.DK.008 nos -

G 96.DK.016 nos -

H 96.DR.015 nos -

Supply and install alumnium door including frames, hardwares, treshold,


steel plate, and all fixing accessories and supports as drawings and
specifications
I 96. DI.003 nos -

J 96. DP.004 nos -

K 96. DP.005 nos -

L 96. DP.007 nos -

M 96. DP.022 nos -

N 96. DP.027 nos -

Supply and install alumnium door including vision panel / louvre, frames,
hardwares, treshold, steel plate, and all fixing accessories and supports as
drawings and specifications

O 96.DQ.009 nos -

P 96.DQ.010 nos -

Q 96.DQ.011 nos -

R 96.DQ.012 nos -

S 96.DQ.019 nos -

TA2459 Lesaffre Garuda 19/65 4788-3e5a-e0c9-5708-2.8


Item BILL NO. 96
96.8 DOORS AND WINDOWS Qty. Unit Rate Rupiahs
No. ADMINISTRATION BUILDING

To Collection Rp. -

96.8.1 DOORS, CONT'D

Supply and install alumnium door including vision panel / louvre, frames,
hardwares, treshold, steel plate, and all fixing accessories and supports as
drawings and specifications

A 96.DQ.020 nos -

B 96.DQ.023 nos -

C 96.DQ.024 nos -

D 96.DQ.025 nos -

E 96.DQ.026 nos -

Supply and install glass door including frames, hardwares, treshold, steel
plate, and all fixing accessories and supports as drawings and specifications

F 96.DT.001 nos -

G 96.DU.006 nos -

H 96.DU.017 nos -

I 96.DU.018 nos -

J 96.DU.028 nos -

K 96.DU.029 nos -

L 96.DU.030 nos -

M 96.DU.031 nos -

N 96.DU.032 nos -

O 96.DU.033 nos -

P 96.DU.034 nos -

Q 96.DU.035 nos -

R 96.DU.036 nos -

S 96.DU.037 nos -

96.DU.038 nos -

96.8.2 WINDOWS

Supply and install aluminium fix window complete with laminated


tempered glass + clear glass, hardwares, and all necessary components,
fixing, accessories as drawing and specification.

T 96.WA.001 nos -

TA2459 Lesaffre Garuda 20/65 4788-3e5a-e0c9-5708-2.8


Item BILL NO. 96
96.8 DOORS AND WINDOWS Qty. Unit Rate Rupiahs
No. ADMINISTRATION BUILDING
U 96.WA.002 nos -

To Collection Rp. -

96.8.2 WINDOWS, CONT'D

Supply and install aluminium fix window complete with laminated


tempered glass + clear glass, hardwares, and all necessary components,
fixing, accessories as drawing and specification.

A 96.WA.005 nos -

B 96.WA.008 nos -

Supply and install aluminium swing window complete with laminated


tempered glass + clear glass, hardwares, and all necessary components,
fixing, accessories as drawing and specification.

C 96.WB.003 nos -

D 96.WB.004 nos -

E 96.WB.006 nos -

F 96.WB.007 nos -

96.8.3 CURTAIN WALL

Supply and install curtain wall system complete with hardwares, and all
necessary components, fixing, accessories as drawing and specification

G 96.SA.001 nos -

H 96.SA.002 nos -

I 96.SB.003 nos -

J 96.SB.004 nos -

K 96.SC.005 nos -

L 96.SD.006 nos -

M 96.SE.007 nos -

N 96.SF.008 nos -

O 96.SF.009 nos -

P 96.SF.010 nos -

Q 96.SF.011 nos -

R 96.SF.012 nos -

S 96.SF.013 nos -

T 96.SF.014 nos -

TA2459 Lesaffre Garuda 21/65 4788-3e5a-e0c9-5708-2.8


Item BILL NO. 96
96.8 DOORS AND WINDOWS Qty. Unit Rate Rupiahs
No. ADMINISTRATION BUILDING

U 96.SG.015 nos -

V 96.SH.016 nos -

To Collection Rp. -

96.8.3 CURTAIN WALL, CONT'D

Supply and install curtain wall system complete with hardwares, and all
necessary components, fixing, accessories as drawing and specification

A 96.SI.017 nos -

B 96.SJ.018 nos -

C 96.SJ.019 nos -

D 96.SJ.020 nos -

E 96.SJ.021 nos -

F 96.SJ.025 nos -

G 96.SJ.026 nos -

H 96.SJ.027 nos -

I 96.SJ.028 nos -

J 96.SJ.029 nos -

K 96.SJ.030 nos -

L 96.SJ.031 nos -

M 96.SK.022 nos -

N 96.SL.023 nos -

O 96.SL.024 nos -

P 96.SM.032 nos -

Q 96.SN.033 nos -

R 96.SN.034 nos -

S 96.SO.035 nos -

T 96.SP.036 nos -

U 96.SQ.037 nos -

V 96.SQ.039 nos -

W 96.SQ.041 nos -

TA2459 Lesaffre Garuda 22/65 4788-3e5a-e0c9-5708-2.8


Item BILL NO. 96
96.8 DOORS AND WINDOWS Qty. Unit Rate Rupiahs
No. ADMINISTRATION BUILDING
X 96.SR.038 nos -

Y 96.SR.040 nos -

Z 96.SR.042 nos -

To Collection Rp. -

96.8.3 CURTAIN WALL, CONT'D

Supply and install curtain wall system complete with hardwares, and all
necessary components, fixing, accessories as drawing and specification

A 96.SR.043 nos -

B 96.SR.044 nos -

C 96.SR.045 nos -

D 96.SS.046 nos -

E 96.ST.047 nos -

F 96.SU.048 nos -

G 96.SU.049 nos -

H 96.SV.050 nos -

To Collection Rp. -

COLLECTIONS

Page 96.8 /1 -

Page 96.8 /2 -

Page 96.8 /3 -

TA2459 Lesaffre Garuda 23/65 4788-3e5a-e0c9-5708-2.8


Item BILL NO. 96
96.8 DOORS AND WINDOWS Qty. Unit Rate Rupiahs
No. ADMINISTRATION BUILDING

Page 96.8 /4 -

Page 96.8 /5 -

96.8 DOORS AND WINDOWS


CARRIED TO SUMMARY AT END OF BILL NO. 96 Rp. -

TA2459 Lesaffre Garuda 24/65 4788-3e5a-e0c9-5708-2.8


Item BILL NO. 96
96.9. FINISHES Qty. Unit Rate Rupiahs
No ADMINISTRATION BUILDING

96.9.1 FLOOR FINISHES

Supply and install waterproofing including screed all in accordance with


manufactured instruction applied: all in accordance with drawings and
specifications

A To Floor Wet Area m2 -

Supply and install Homogenous Tile complete with screed, gape grouting
and all in accordance with manufactured instruction applied: all in
accordance with drawings and specifications

B To Floor m2 -

C To Skirting m -

Supply and install Epoxy coating including all necessary and all in
accordance with manufactured instruction applied: all in accordance with
drawings and specifications

D To Floor m2 -

E To Skirting m -

Raised floor including all necessary and all in accordance with


manufactured instruction applied: all in accordance with drawings and
specifications
F To Floor m2 -

Carpet tile including support and all necessary; all in accordance with
manufactured instruction applied: all in accordance with drawings and
specifications
G To Floor m2 -

H To Skirting, aluminium skirting m -

96.9.2 WALL FINISHES

Supply and install Homogenous Tile complete with screed, gape grouting
and all in accordance with manufactured instruction applied: all in
accordance with drawings and specifications

I Applied to wall m2 -

Prepare smooth and apply waterbased acrylic emulsion paint finish, in


accordance with manufacturer's recommendations, as specified to face of :

J Applied to plastered autoclaved concrete walls (Internal Wall) m2 -

Prepare smooth and apply waterbased wethershield emulsion paint finish,


in accordance with manufacturer's recommendations, as specified to face of
:
K Applied to plastered autoclaved concrete walls (External Wall) m2 -

Prepare smooth and apply epoxy paint, in accordance with manufacturer's


recommendations, as drawing and specification

L Applied to plastered autoclaved concrete walls (Internal Wall) m2 -

TA2459 Lesaffre Garuda 25/65 4788-3e5a-e0c9-5708-2.9


Item BILL NO. 96
96.9. FINISHES Qty. Unit Rate Rupiahs
No ADMINISTRATION BUILDING

To Collection Rp. -

96.9.2 WALL FINISHES, CONT'D

Prepare smooth and apply skimcoat, in accordance with manufacturer's


recommendations, as drawing and specification

A To Exposed Concrete m2 -

Supply and install waterproofing including screed all in accordance with


manufactured instruction applied: all in accordance with drawings and
specifications

B To Wall Wet Area m2 -

96.9.3 CEILING FINISHES

Prepare smooth and apply waterbased acrylic emulsion paint finish, in


accordance with manufacturer's recommendations, as specified to face of :

C To Ceiling m2 -

Prepare smooth and apply skimcoat, in accordance with manufacturer's


recommendations, as drawing and specification

D To Exposed Concrete m2 -

To Collection Rp. -

COLLECTIONS

Page 96.9 /1 -

Page 96.9 /2 -

TA2459 Lesaffre Garuda 26/65 4788-3e5a-e0c9-5708-2.9


Item BILL NO. 96
96.9. FINISHES Qty. Unit Rate Rupiahs
No ADMINISTRATION BUILDING

96.9. FINISHES
CARRIED TO SUMMARY AT END OF BILL NO. 96 Rp. -

TA2459 Lesaffre Garuda 27/65 4788-3e5a-e0c9-5708-2.9


Item BILL NO. 96
96.10 SPECIALITIES Qty. Unit Rate Rupiahs
No ADMINISTRATION BUILDING

96.10.1 INTERIOR SPECIALITIES

Supply and install sanitary wares complete with all necessary in


accordance with manufacturer's recommendations as drawing and
specification
A SF8, Wall Mounted nos -

B SF9, Toilet Cubicle nos -

C SF10, Toilet Seated nos -

D SF11, Floor Drain nos -

E SF12, Jet Shower nos -

F SF13, Urinoir nos -

G SF14, Urinal Partition nos -

H SF16, Self Closing nos -

I SF17, Under Counter Lavatory nos -

J SF18, Wall Hung Lavatory nos -

K SF19, Paper Towel Holder nos -

L SF23, Mirror Male Toilet nos -

M SF23, Mirror Female Toilet nos -

M SF24, Soap Dispenser nos -

N SF28, Paper Towel Dispenser nos -

O SF30, Safety Grab Rail nos -

96.10.2 FURNITURES

Supply and install furnitures complete with all necessary in accordance


with manufacturer's recommendations as drawing and specification

P FU04, Bench nos -

Q FU05, Hairnet and Mask Container nos -

R FU06, Waste Bin nos -

S FU07, Locker nos -

96.10.3 INTERIOE WORKS excluded

TA2459 Lesaffre Garuda 28/65 4788-3e5a-e0c9-5708-2.10


Item BILL NO. 96
96.10 SPECIALITIES Qty. Unit Rate Rupiahs
No ADMINISTRATION BUILDING

96.10 SPECIALITIES
CARRIED TO SUMMARY AT END OF BILL NO. 96 Rp. -

TA2459 Lesaffre Garuda 29/65 4788-3e5a-e0c9-5708-2.10


Item BILL NO. 96
96.11 MECHANICAL WORKS Qty. Unit Rate Rupiahs
No ADMINISTRATION BUILDING

96.11 MECHANICAL WORKS

96.11.1 DOMESTIC COLD WATER

DOMESTIC COLD WATER SYSTEM INSTALLATION


Supply and install Domestic Water pipes; PPR PN 10 including fittings (for 50
mm dia. Pipe or less) fixed in position complete with seals (for underground
pipe) supports, hangers, brackets, clamp, painting, and other necessary fixing
and jointing material in accordance to the technical specification and drawings,
as described;

PIPEWORKS

A 15mm diameter pipe m

B 20mm diameter pipe m

C 25mm diameter pipe m

D 32mm diameter pipe m

E 40mm diameter pipe m

F 50mm diameter pipe m

VALVE AND ANCILLARIES

G 25mm diameter gate valve no

H 32mm diameter gate valve no

I 40mm diameter gate valve no

J 50mm diameter gate valve no

K AAV; 25mm diameter no

96.11.2 SEWAGE AND WASTE WATER SYSTEM

SEWAGE AND WASTE WATER SYSTEM INSTALLATION


Supply and Install Waste water, Sewage water pipes and Venting pipes; PVC Class
AW 10 kg/m2 including fittings (for 50 mm dia. Pipe or less) fixed in position
complete with supports, hangers, brackets, clamp, painting, and other necessary
fixing and jointing material in accordance to the technical specification and
drawings, as described;

PIPEWORKS (SEWAGE AND WASTE)

L 50mm diameter pipe m

M 100mm diameter pipe m

N 150mm diameter pipe m

O 200mm diameter pipe m

TA2459 Lesaffre Garuda 30/65 4788-3e5a-e0c9-5708-2.11


Item BILL NO. 96
96.11 MECHANICAL WORKS Qty. Unit Rate Rupiahs
No ADMINISTRATION BUILDING

To Collection Rp. -

TA2459 Lesaffre Garuda 31/65 4788-3e5a-e0c9-5708-2.11


Item BILL NO. 96
96.11 MECHANICAL WORKS Qty. Unit Rate Rupiahs
No ADMINISTRATION BUILDING

SEWAGE AND WASTE WATER SYSTEM INSTALLATION (Cont'd)


Supply and Install Waste water, Sewage water pipes and Venting pipes; PVC Class
AW 10 kg/m2 including fittings (for 50 mm dia. Pipe or less) fixed in position
complete with supports, hangers, brackets, clamp, painting, and other necessary
fixing and jointing material in accordance to the technical specification and
drawings, as described;

PIPEWORKS (VENTING)

A 40mm diameter pipe m

B 50mm diameter pipe m

FITTINGS

C Fitting 100mm diameter no

D Fitting 150mm diameter no

E Fitting 200mm diameter no

VALVE AND ANCILLARIES

F Ventcap 50mm diameter no

G Clean out 50mm diameter no

H Clean out 100mm diameter no

96.11.3 HYDRANT & SPRINKLER SYSTEM

HYDRANT SYSTEM INSTALLATION


Supply and install Hydrant pipes, Black steel pipe to ASTM A 53 schedule 40 ,
Grade B, including fitting (for 50 mm dia. Pipe or less) fixed in position complete
with supports, hangers, brackets, clamp, painting, and other necessary fixing and
jointing material in accordance to the technical specification and drawings, as
described;

PIPEWORKS

I 40mm diameter pipe m

J 65mm diameter pipe m

K 80mm diameter pipe m

L 100mm diameter pipe m

M 150mm diameter pipe m

N 200mm diameter pipe m

TA2459 Lesaffre Garuda 32/65 4788-3e5a-e0c9-5708-2.11


Item BILL NO. 96
96.11 MECHANICAL WORKS Qty. Unit Rate Rupiahs
No ADMINISTRATION BUILDING

To Collection Rp. -

TA2459 Lesaffre Garuda 33/65 4788-3e5a-e0c9-5708-2.11


Item BILL NO. 96
96.11 MECHANICAL WORKS Qty. Unit Rate Rupiahs
No ADMINISTRATION BUILDING

HYDRANT SYSTEM INSTALLATION (Cont'd)


Supply and install Hydrant pipes, Black steel pipe to ASTM A 53 schedule 40 ,
Grade B, including fitting (for 50 mm dia. Pipe or less) fixed in position complete
with supports, hangers, brackets, clamp, painting, and other necessary fixing and
jointing material in accordance to the technical specification and drawings, as
described;

FITTINGS

A Fitting 65mm diameter no

B Fitting 80mm diameter no

C Fitting 100mm diameter no

D Fitting 150mm diameter no

VALVE AND ANCILLARIES

E Gate valve; 100mm diameter, UL listed & FM approved no

F Portable fire extinguisher with capacity 6 kg chemical powder ABC type. no

G Portable fire extinguisher with capacity 6 kg chemical powder C02 type. no

H Portable fire extinguisher with capacity 25 kg dry chemical CO2 type c/w trolley. no

I Indoor Hydrant Box (IHB) complete with hose rack, rubber hose, hose reel, valve no
and nozzle

SPRINKLER SYSTEM INSTALLATION


Supply and install Sprinkler pipes, Black steel pipe to ASTM A 53 schedule 40 ,
Grade B, including fitting (for 50 mm dia. Pipe or less) fixed in position complete
with supports, hangers, brackets, clamp, painting, and other necessary fixing and
jointing material in accordance to the technical specification and drawings, as
described;

PIPEWORKS

J 25mm diameter pipe m

K 32mm diameter pipe m

L 40mm diameter pipe m

M 50mm diameter pipe m

N 65mm diameter pipe m

O 80mm diameter pipe m

P 100mm diameter pipe m

Q 150mm diameter pipe m

R 200mm diameter pipe m

TA2459 Lesaffre Garuda 34/65 4788-3e5a-e0c9-5708-2.11


Item BILL NO. 96
96.11 MECHANICAL WORKS Qty. Unit Rate Rupiahs
No ADMINISTRATION BUILDING

To Collection Rp. -

TA2459 Lesaffre Garuda 35/65 4788-3e5a-e0c9-5708-2.11


Item BILL NO. 96
96.11 MECHANICAL WORKS Qty. Unit Rate Rupiahs
No ADMINISTRATION BUILDING

SPRINKLER SYSTEM INSTALLATION (Cont'd)


Supply and install Sprinkler pipes, Black steel pipe to ASTM A 53 schedule 40 ,
Grade B, including fitting (for 50 mm dia. Pipe or less) fixed in position complete
with supports, hangers, brackets, clamp, painting, and other necessary fixing and
jointing material in accordance to the technical specification and drawings, as
described;

FITTINGS

A Fitting 65mm diameter no

B Fitting 80mm diameter no

C Fitting 100mm diameter no

D Fitting 150mm diameter no

E Fitting 200mm diameter no

VALVE AND ANCILLARIES

F Head sprinkler pendant type no

G Head sprinkler upright type no

H Branch Control Valve (BCV); 100mm diameter set

I Branch Control Valve (BCV); 150mm diameter set

J Branch Control Valve (BCV); 200mm diameter set

K Alarm Control Valve (ACV); 100mm diameter set

L Alarm Control Valve (ACV); 200mm diameter set

M Main Control Valve (MCV); 150mm diameter no

N AAV; 25mm diameter no

O Test Drain; 25 mm diameter set

P Flexible coupling; 100mm diameter no

Q Flexible coupling; 150mm diameter no

R Flexible coupling; 200mm diameter no

TA2459 Lesaffre Garuda 36/65 4788-3e5a-e0c9-5708-2.11


Item BILL NO. 96
96.11 MECHANICAL WORKS Qty. Unit Rate Rupiahs
No ADMINISTRATION BUILDING

To Collection Rp. -

TA2459 Lesaffre Garuda 37/65 4788-3e5a-e0c9-5708-2.11


Item BILL NO. 96
96.11 MECHANICAL WORKS Qty. Unit Rate Rupiahs
No ADMINISTRATION BUILDING

COLLECTION

Page 96.11 /1 -

Page 96.11 /2 -

Page 96.11 /3 -

Page 96.11 /4 -

96.11 MECHANICAL WORKS


CARRIED TO SUMMARY AT END OF BILL NO. 96 Rp. -

TA2459 Lesaffre Garuda 38/65 4788-3e5a-e0c9-5708-2.11


Item BILL NO. 96
96.11 MECHANICAL WORKS Qty. Unit Rate Rupiahs
No ADMINISTRATION BUILDING

TA2459 Lesaffre Garuda 39/65 4788-3e5a-e0c9-5708-2.11


Item BILL NO. 96
96.12 ELECTRICAL WORKS Qty. Unit Rate Rupiahs
No ADMINISTRATION BUILDING

96.12 ELECTRICAL WORKS

96.12.1 SUB DISTRIBUTION BOARDS


Supply, Install and Testing Commissioning the following Sub Distribution board
fix in position includes circuit breaker, board, busbar, digital multimeter,
contactor, surge arrester, potensial transformer, current transformer, indicator
lamp, fuse, loto, star / stop push button, and all necessary accessories in
arcondance to the technical spesification as shown on drawing, as described : -

A 96DB01 no

B 96DB02 no

C 96DB-E_UPS no

D Industrial 3Ph Outlet no

E UPS 380 VAC, 10 kVA no

F 96DBAC01 no

96.12.2 MAIN AND SUB-MAINS CABLES


Supply and Install the following Main and Sub-Mains circuit distribution cable
run & fixed on cable tray/ladders including all necessary accessories in
arcondance to the technical spesification as shown on drawing, as described : -

G From SDB…. to 92DB01 m by other package

H From SDB…. to 92DB02 m by other package

I From 96DB01 to DB-E-UPS NYY 5x4mm2 m

J From DB-E-UPS to local panel NYY 3x4mm2 m

96.12.3 LIGHTING FIXTURES & POWER OUTLET


Supply and Install the following light fittings including tubes or lamps fixed in
position complete with all accessories and support in accordance with the
technical specification and drawings, as described :-

K Recessed mounted TLED 40W, 220V, 3709 lm no

L Recessed mounted TLED 40W, 220V, 3709 lm, c/w nicad battery duration 1 no
hour

M Exit sign LED 5W, 220V, wall mounted no

N Waterproof LED 20W, 220V, IP65, 2000 lm, L600 no

O Waterproof LED 20W, 220V, IP65, 2000 lm, L600, c/w nicad battery duration 1 no
hour

P Downlight 16W, 220V, minimum 1200 lm no

Q Downlight 16W, 220V, minimum 1200 lm, c/w nicad battery duration 1 hour no

R Surface downlight 16W, 220V, minimum 1200 lm no

To Collection Rp. -

TA2459 Lesaffre Garuda 40/65 4788-3e5a-e0c9-5708-2.12


Item BILL NO. 96
96.12 ELECTRICAL WORKS Qty. Unit Rate Rupiahs
No ADMINISTRATION BUILDING

TA2459 Lesaffre Garuda 41/65 4788-3e5a-e0c9-5708-2.12


Item BILL NO. 96
96.12 ELECTRICAL WORKS Qty. Unit Rate Rupiahs
No ADMINISTRATION BUILDING

96.12.3 LIGHTING FIXTURES & POWER OUTLET (Cont'd)


Supply and Install the following switches including provision of steel/metal box
and all accessories accordance with the technical specification and drawings, as
described :-

A Single gang, 1 way switch, 10A no

B Double gang, 1 way switch, 10A no

Supply and Install lighting & switch cables from sub circuit to final circuit
including grounding system and all neccessary accessories accordance with the
technical specification and drawings, as described :-

C Cabling point from local panel (500V/CU/PVC 3C x 2.5 mm² shall be UV & no
chemical resistance) run-in and with PVC high impact conduit) to; lighting and
switch

POWER OUTLET
Supply and Install the following power outlet including provision of steel/metal
box and all accessories accordance with the Technical Specification and
drawings, as described :-

D General socket outlet, wall mounted, 16A, 250V, single gang no

E General socket outlet, wall mounted, 16A, 250V, double gang no

F General socket outlet hand dryer, wall mounted, 16A, 250V, (waterproof) single no
gang

G Industrial socket outlet, wall mounted 16A, 250V, IP65, 1Ph no

H Industrial socket outlet, wall mounted 32A, 400V, IP65, 3Ph no

96.12.4 TRAYS AND LADDERS


Supply and Install hot dip galvanized tray and ladder 2mm thickness include
jointing, elbow, tee, fixing accessories and hangers and all necessary accessories
accordance with the technical specification and drawings, as described :-

Electrical
I Cable tray 300x100mm m

J Cable ladder 100x100mm m

Electronic
K Cable tray 300x100mm m

L Cable tray 200x100mm m

M Cable tray 100x100mm m

To Collection Rp. -

TA2459 Lesaffre Garuda 42/65 4788-3e5a-e0c9-5708-2.12


Item BILL NO. 96
96.12 ELECTRICAL WORKS Qty. Unit Rate Rupiahs
No ADMINISTRATION BUILDING

TA2459 Lesaffre Garuda 43/65 4788-3e5a-e0c9-5708-2.12


Item BILL NO. 96
96.12 ELECTRICAL WORKS Qty. Unit Rate Rupiahs
No ADMINISTRATION BUILDING

96.12.5 GROUNDING & LIGHTNING PROTECTION SYSTEM


Supply and Install Grounding system for panel and equipment complete with
support and all neccessary accessories accordance with the technical
specification and drawings, as described :-

A Earth pit, Conductor clamp and rod electrode, dia 19mm x 3000 length no

B Earthing bonding bar (copper bar) 40x3mm thk, c/w isolator no

C BC 70mm2, grounding cable for main/mesh earthing c/w connector and m


grounding lug

D Potential earth clamp (100kA) no

E Bonding cable NYAF 16mm2 m

F Bonding cable NYAF 25mm2 m

G Bonding cable NYAF 35mm2 m

96.12.6 FIRE ALARM


Supply and Install the following Fire Alarm Equipment complete with support, and
all necessary accessories in accordance to the technical specification and
drawings, as described : -

H JBFA-96-01 no

I Addressable photoelectric smoke detector no

I Addressable fixed heat detector no

J Addressable manual call point no

K Horn & strobe light no

L End of line (EOL) no

Supply and Install the following Fire Alarm cables in final sub-circuit to
termination, run-in and with steel conduit 20mm dia; including earthing system
and all necessary accessories in accordance to the technical spesification as
shown on drawing, as described : -

M Power Cable FRC 2Cx2,5 mm2; from control room BD50 m

N Cable FRC STP 2Cx1,5 mm2; for detector point no

O Cable FRC STP 2Cx1,5 mm2; for manual call point no

P Cable FRC 2Cx1,5 mm2; for horn & strobe light point no

To Collection Rp. -

TA2459 Lesaffre Garuda 44/65 4788-3e5a-e0c9-5708-2.12


Item BILL NO. 96
96.12 ELECTRICAL WORKS Qty. Unit Rate Rupiahs
No ADMINISTRATION BUILDING

TA2459 Lesaffre Garuda 45/65 4788-3e5a-e0c9-5708-2.12


Item BILL NO. 96
96.12 ELECTRICAL WORKS Qty. Unit Rate Rupiahs
No ADMINISTRATION BUILDING

96.12.7 PUBLIC ADDRESS


Supply and Install the following Sound System Equipment complete with support,
and all necessary accessories in accordance to the technical specification and
drawings, as described : -

A MDFPA no

B Wall mounted switch rack JBPA-96-01 (SR-96-01) no

C Indoor ceiling mounted speaker 6W no

Supply and Install the following Public Address cables in final sub-circuit to
termination, run-in and with steel conduit 20mm dia; including earthing system
and all necessary accessories in accordance to the technical spesification as
shown on drawing, as described : -

D Cable NYMHY 2Cx1,5 mm2; for indor ceiling speaker point no

96.12.8 DATA AND TELEPHONE


Supply and Install the following Data and Communication System
Equipment complete with support, and all necessary accessories in
accordance to the technical specification and drawings, as described : -

E Wall mounted switch rack SR-96-01 no

F Single gang type data outlet (RJ45) no

G Single gang type telephone outlet (RJ45) no

Supply and Install the following Data and Telephone cables in final sub-circuit
to termination, run-in and with steel conduit 20mm dia; including earthing system
and all necessary accessories in accordance to the technical spesification as
shown on drawing, as described : -

H Cable UTP-CAT6/FO mm2; from server room BD96 m

I Cable UTP-CAT6/FO mm2; for data outlet point no

J Cable UTP-CAT6/FO mm2; for data outlet point no

K Cable UTP-CAT6/FO mm2; for telephone outlet point no

96.12.9 SECURITY SYSTEM


Supply and Install the following Security System Equipment complete with
support, and all necessary accessories in accordance to the technical specification
and drawings, as described : -

L Wall mounted switch rack SR-96-01 no

M IP based dome camera no

N Acces control door consist of; no


Door control
Finger print / card reader
Push button door release

To Collection Rp. -

TA2459 Lesaffre Garuda 46/65 4788-3e5a-e0c9-5708-2.12


Item BILL NO. 96
96.12 ELECTRICAL WORKS Qty. Unit Rate Rupiahs
No ADMINISTRATION BUILDING

TA2459 Lesaffre Garuda 47/65 4788-3e5a-e0c9-5708-2.12


Item BILL NO. 96
96.12 ELECTRICAL WORKS Qty. Unit Rate Rupiahs
No ADMINISTRATION BUILDING

96.12.9 SECURITY SYSTEM (Cont'd)


Supply and Install the following Security cables in final sub-circuit to
termination, run-in and with PVC conduit 25mm dia underground direct burried
min 500mm below grade or through pipe rack; including earthing system and all
necessary accessories in accordance to the technical spesification as shown on
drawing, as described : -

A Cable UTP-CAT6/FO mm2; from server room BD96 m

B Cable UTP-CAT6/FO; for bullet dome camera no

C Cable UTP-CAT6/FO; for acces control door point no

To Collection Rp. -

COLLECTIONS

Page 96.12 /1 -

Page 96.12 /2 -

Page 96.12 /3 -

Page 96.12 /4 -

Page 96.12 /5 -

96.12 ELECTRICAL WORKS


CARRIED TO SUMMARY AT END OF BILL NO. 96 Rp. -

TA2459 Lesaffre Garuda 48/65 4788-3e5a-e0c9-5708-2.12


Item BILL NO. 96
96.12 ELECTRICAL WORKS Qty. Unit Rate Rupiahs
No ADMINISTRATION BUILDING

TA2459 Lesaffre Garuda 49/65 4788-3e5a-e0c9-5708-2.12


Item BILL NO. 96
96.13 HVAC WORKS Qty. Unit Rate Rupiahs
No ADMINISTRATION BUILDING

96.13 HVAC WORKS

96.13.1 EQUIPMENT

VRF UNIT
Supply and Install of VRF Units complete with hangers/supports, vibration
mountings, neoprene pads and all necessary accessories in accordance to
the technical specification and drawings, as described : -

A IU-VRF.96.00.01; fresh air type, cooling capacity 16kWth, supply no


air flow 888 CMH, static pressure 220 pa, 0.75kW, 380V/3Ph/50Hz

B IU-VRF.96.00.02A-B; 2 way cassette, cooling capacity 2.1kWth, supply no


air flow 570 CMH, static pressure 220 pa, 0.1kW, 220V/1Ph/50Hz

C IU-VRF.96.00.03; fresh air type, cooling capacity 22kWth, supply no


air flow 1451 CMH, static pressure 220 pa, 1.1kW, 380V/3Ph/50Hz

D IU-VRF.96.00.04; 1 way cassette, cooling capacity 2.4kWth, supply no


air flow 558 CMH, free blow, 0.1kW, 220V/1Ph/50Hz

E IU-VRF.96.00.05; wall mounted, cooling capacity 2.4kWth, supply air no


flow 354 CMH, free blow, 0.1kW, 220V/1Ph/50Hz

F IU-VRF.96.00.06; wall mounted, cooling capacity 1.3kWth, supply air no


flow 318 CMH, free blow, 0.1kW, 220V/1Ph/50Hz

G IU-VRF.96.00.07; wall mounted, cooling capacity 2.4kWth, supply air no


flow 354 CMH, free blow, 0.1kW, 220V/1Ph/50Hz

H IU-VRF.96.00.08; wall mounted, cooling capacity 1.1kWth, supply air no


flow 318 CMH, free blow, 0.1kW, 220V/1Ph/50Hz

I IU-VRF.96.00.09; high static split duct, cooling capacity 11kWth, supply air no
flow 2280 CMH, static pressure 220 pa, 0.37kW, 220V/1Ph/50Hz

J IU-VRF.96.00.10; fresh air type, cooling capacity 16kWth, supply no


air flow 873 CMH, static pressure 220 pa, 0.37kW, 380V/3Ph/50Hz

K IU-VRF.96.00.11; high static split duct, cooling capacity 14kWth, supply air no
flow 2280 CMH, static pressure 220 pa, 0.37kW, 220V/1Ph/50Hz

L IU-VRF.96.00.12A-B; high static split duct, cooling capacity 22kWth, supply air no
flow 2400 CMH, static pressure 220 pa, 0.75kW, 380V/2Ph/50Hz

M IU-VRF.96.01.01; wall mounted, cooling capacity 2kWth, supply air no


flow 348 CMH, free blow, 0.1kW, 220V/1Ph/50Hz

N IU-VRF.96.01.02; 2 way cassette, cooling capacity 3.3kWth, supply air no


flow 570 CMH, free blow, 0.1kW, 220V/1Ph/50Hz

O IU-VRF.96.01.03; 2 way cassette, cooling capacity 3.3kWth, supply air no


flow 570 CMH, free blow, 0.1kW, 220V/1Ph/50Hz

To Collection Rp. -

TA2459 Lesaffre Garuda 50/65 4788-3e5a-e0c9-5708-2.13


Item BILL NO. 96
96.13 HVAC WORKS Qty. Unit Rate Rupiahs
No ADMINISTRATION BUILDING

TA2459 Lesaffre Garuda 51/65 4788-3e5a-e0c9-5708-2.13


Item BILL NO. 96
96.13 HVAC WORKS Qty. Unit Rate Rupiahs
No ADMINISTRATION BUILDING

96.13.1 EQUIPMENT (Cont'd)

VRF UNIT
Supply and Install of VRF Units complete with hangers/supports, vibration
mountings, neoprene pads and all necessary accessories in accordance to
the technical specification and drawings, as described : -

A IU-VRF.96.01.04; 2 way cassette, cooling capacity 4.4kWth, supply air no


flow 750 CMH, free blow, 0.1kW, 220V/1Ph/50Hz

B IU-VRF.96.01.05; 2 way cassette, cooling capacity 4.4kWth, supply air no


flow 750 CMH, free blow, 0.1kW, 220V/1Ph/50Hz

C IU-VRF.96.01.06; 2 way cassette, cooling capacity 3.3kWth, supply air no


flow 570 CMH, free blow, 0.1kW, 220V/1Ph/50Hz

D IU-VRF.96.01.07A-B; 2 way cassette, cooling capacity 3.6kWth, supply air no


flow 750 CMH, free blow, 0.1kW, 220V/1Ph/50Hz

E IU-VRF.96.01.08; mid static split duct, cooling capacity 1.8kWth, supply air no
flow 316 CMH, static pressure 100 pa, 0.1kW, 220V/1Ph/50Hz

F IU-VRF.96.01.09A-D; high static split duct, cooling capacity 10.5kWth, supply no


air flow 2280 CMH, static pressure 220 pa, 0.37kW, 220V/1Ph/50Hz

G IU-VRF.96.01.10; ceiling suspend, cooling capacity 10.5kWth, supply no


air flow 1680 CMH, free blow, 0.75kW, 220V/1Ph/50Hz

H IU-VRF.96.01.11A-B; mid static split duct, cooling capacity 2.3kWth, supply air no
flow 510 CMH, static pressure 100 pa, 0.1kW, 220V/1Ph/50Hz

I IU-VRF.96.01.12; mid static split duct, cooling capacity 2.3kWth, supply air no
flow 510 CMH, static pressure 100 pa, 0.1kW, 220V/1Ph/50Hz

J IU-VRF.96.01.13; mid static split duct, cooling capacity 2.3kWth, supply air no
flow 510 CMH, static pressure 100 pa, 0.1kW, 220V/1Ph/50Hz

K IU-VRF.96.01.14; fresh air type, cooling capacity 14kWth, supply air no


flow 683 CMH, static pressure 220 pa, 0.1kW, 220V/1Ph/50Hz

L OU-VRF.96.00.01; air cooled VRF, cooling capacity 4kWth, supply air no


flow 10500CMH/module, static pressure 75 pa, 2.2kW, 220V/1Ph/50Hz

M OU-VRF.96.00.02; air cooled VRF, cooling capacity 3.4kWth, supply air no


flow 10500CMH/module, static pressure 85 pa, 11kW, 380V/3Ph/50Hz

N OU-VRF.96.00.03; air cooled VRF, cooling capacity 3.7kWth, supply air no


flow 10500CMH/module, static pressure 80 pa, 10.5kW, 380V/3Ph/50Hz

O OU-VRF.96.01.01; air cooled VRF, cooling capacity 3kWth, supply air no


flow 10500CMH/module, static pressure 85 pa, 11kW, 380V/3Ph/50Hz

To Collection Rp. -

TA2459 Lesaffre Garuda 52/65 4788-3e5a-e0c9-5708-2.13


Item BILL NO. 96
96.13 HVAC WORKS Qty. Unit Rate Rupiahs
No ADMINISTRATION BUILDING

TA2459 Lesaffre Garuda 53/65 4788-3e5a-e0c9-5708-2.13


Item BILL NO. 96
96.13 HVAC WORKS Qty. Unit Rate Rupiahs
No ADMINISTRATION BUILDING

96.13.1 EQUIPMENT (Cont'd)

DX UNIT
Supply and Install of DX Units complete with hangers/supports, vibration
mountings, neoprene pads and all necessary accessories in accordance to
the technical specification and drawings, as described : -

A IU-DX.96.00.01A-B; ceiling suspend, cooling capacity 10.6kWth, supply no


air flow 1520 CMH, 0.1kW, 220V/1Ph/50Hz

B OU-DX.96.00.01A-B; air cooled inverter, cooling capacity 10.6kWth, supply no


air flow 4800 CMH, 3.5kW, 220V/1Ph/50Hz

HEAT EXCHANGER UNIT


Supply and Install of Heat Exchanger Units complete with hangers/supports,
vibration mountings, neoprene pads and all necessary accessories in accordance
to the technical specification and drawings, as described : -

C HEXV-92.02.01, heat exchanger, air flow 746 CMH, static pressure 150 pa, no
0.55kW, 220V/1Ph/50Hz

D HEXV-92.00.01, heat exchanger, air flow 1087 CMH, static pressure 160 pa, no
0.55kW, 220V/1Ph/50Hz

E HEXV-92.01.01, heat exchanger, air flow 518 CMH, static pressure 150 pa, no
0.55kW, 220V/1Ph/50Hz

F HEXV-92.01.02, heat exchanger, air flow 728 CMH, static pressure 150 pa, no
0.55kW, 220V/1Ph/50Hz

FAN
Supply and Install of Fan Units complete with hangers/supports, vibration
mountings, neoprene pads and all necessary accessories in accordance to the
technical specification and drawings, as described : -

G Exhasut Fan EF-96.00.01, centrifugal with accoustic case, cap 2179 CMH, no
static pressure 372 pa, 0.37kW, 220V/1Ph/50Hz

H Exhasut Fan EF-96.00.02, mixflow inline, cap 683 CMH, static pressure 147 pa, no
0.37kW, 220V/1Ph/50Hz

I Exhasut Fan EF-96.00.03, mixflow inline, cap 852 CMH, static pressure 211 pa, no
0.37kW, 220V/1Ph/50Hz

J Exhasut Fan EF-96.02.01, mixflow inline, cap 683 CMH, static pressure 147 pa, no
0.37kW, 220V/1Ph/50Hz

To Collection Rp. -

TA2459 Lesaffre Garuda 54/65 4788-3e5a-e0c9-5708-2.13


Item BILL NO. 96
96.13 HVAC WORKS Qty. Unit Rate Rupiahs
No ADMINISTRATION BUILDING

TA2459 Lesaffre Garuda 55/65 4788-3e5a-e0c9-5708-2.13


Item BILL NO. 96
96.13 HVAC WORKS Qty. Unit Rate Rupiahs
No ADMINISTRATION BUILDING

96.13.2 DUCTWORK
Supply and Install galvanized steel sheet ductworks complete with
hangers, supports, brackets and all necessary fixing accessories in
accordance to the technical tpecification and drawings, as described :-

SUPPLY AIR DUCT


With external insulation (closed cell elastomeric fire retardant type class 0,
FM Approved, 50mm thickness + AL sheet Jacketing 0.4mm thckness)

A Supply air duct (SAD) ; 350mm diameter m

B Supply air duct (SAD) ; 450mm diameter m

C Supply air duct (SAD) ; 500x300mm m

D Supply air duct (SAD) ; 450x250mm m

E Supply air duct (SAD) ; 400x300mm m

F Supply air duct (SAD) ; 400x250mm m

G Supply air duct (SAD) ; 350x250mm m

H Supply air duct (SAD) ; 350x200mm m

I Supply air duct (SAD) ; 300x250mm m

J Supply air duct (SAD) ; 300x200mm m

K Supply air duct (SAD) ; 250x200mm m

L Supply air duct (SAD) ; 200x250mm m

M Supply air duct (SAD) ; 200x200mm m

N Supply air duct (SAD) ; 200x150mm m

O Supply air duct (SAD) ; 150x150mm m

Install Textile Fabric duct including with support/rail and similar to it, fittings &
another accessories which are comply to clean room installation
requirement standard in accordance to the technical tpecification and
drawings, as described :-

P Supply air duct (SAD) ; 700mm diameter m

FRESH AIR DUCT


With external insulation (closed cell elastomeric fire retardant type class 0,

Q Fresh air duct (FAD) ; 500x300mm m

R Fresh air duct (FAD) ; 350x300mm m

S Fresh air duct (FAD) ; 350x250mm m

To Collection Rp. -

TA2459 Lesaffre Garuda 56/65 4788-3e5a-e0c9-5708-2.13


Item BILL NO. 96
96.13 HVAC WORKS Qty. Unit Rate Rupiahs
No ADMINISTRATION BUILDING

TA2459 Lesaffre Garuda 57/65 4788-3e5a-e0c9-5708-2.13


Item BILL NO. 96
96.13 HVAC WORKS Qty. Unit Rate Rupiahs
No ADMINISTRATION BUILDING

96.13.2 DUCTWORK (Cont'd)


Supply and Install galvanized steel sheet ductworks complete with
hangers, supports, brackets and all necessary fixing accessories in
accordance to the technical tpecification and drawings, as described :-

FRESH AIR DUCT


With external insulation (closed cell elastomeric fire retardant type class 0,
FM Approved, 32mm thickness + AL sheet Jacketing 0.4mm thckness)

A Fresh air duct (FAD) ; 300x300mm m

B Fresh air duct (FAD) ; 300x250mm m

C Fresh air duct (FAD) ; 300x200mm m

D Fresh air duct (FAD) ; 250x200mm m

E Fresh air duct (FAD) ; 200x200mm m

F Fresh air duct (FAD) ; 150x150mm m

Install Textile Fabric duct including with support/rail and similar to it, fittings &
another accessories which are comply to clean room installation
requirement standard in accordance to the technical tpecification and
drawings, as described :-

G Return air duct (RAD) ; 200x200mm m

RETURN AIR DUCT


With external insulation (closed cell elastomeric fire retardant type class 0,
FM Approved, 32mm thickness + AL sheet Jacketing 0.4mm thckness)

H Return air duct (RAD) ; 300mm diameter m

I Return air duct (RAD) ; 825x225mm m

J Return air duct (RAD) ; 450x250mm m

K Return air duct (RAD) ; 400x300mm m

L Return air duct (RAD) ; 400x250mm m

M Return air duct (RAD) ; 350x250mm m

N Return air duct (RAD) ; 300x250mm m

O Return air duct (RAD) ; 250x200mm m

P Return air duct (RAD) ; 200x200mm m

Q Return air duct (RAD) ; 200x150mm m

R Return air duct (RAD) ; 150x150mm m

To Collection Rp. -

TA2459 Lesaffre Garuda 58/65 4788-3e5a-e0c9-5708-2.13


Item BILL NO. 96
96.13 HVAC WORKS Qty. Unit Rate Rupiahs
No ADMINISTRATION BUILDING

TA2459 Lesaffre Garuda 59/65 4788-3e5a-e0c9-5708-2.13


Item BILL NO. 96
96.13 HVAC WORKS Qty. Unit Rate Rupiahs
No ADMINISTRATION BUILDING

96.13.2 DUCTWORK (Cont'd)


Supply and Install galvanized steel sheet ductworks complete with
hangers, supports, brackets and all necessary fixing accessories in
accordance to the technical tpecification and drawings, as described :-

RETURN AIR DUCT


Install Textile Fabric duct including with support/rail and similar to it, fittings &
another accessories which are comply to clean room installation
requirement standard in accordance to the technical tpecification and
drawings, as described :-

A Return air duct (RAD) ; 300x250mm m

B Return air duct (RAD) ; 400x300mm m

EXHAUST AIR DUCT


With external insulation (closed cell elastomeric fire retardant type class 0,
FM Approved, 25mm thickness + AL sheet Jacketing 0.4mm thckness)

C Exhaust air duct (EAD) ; 500x300mm m

D Exhaust air duct (EAD) ; 350x250mm m

E Exhaust air duct (EAD) ; 325x225mm m

F Exhaust air duct (EAD) ; 300x300mm m

G Exhaust air duct (EAD) ; 300x250mm m

H Exhaust air duct (EAD) ; 300x200mm m

I Exhaust air duct (EAD) ; 250x250mm m

J Exhaust air duct (EAD) ; 250x200mm m

K Exhaust air duct (EAD) ; 200x200mm m

L Exhaust air duct (EAD) ; 200x150mm m

96.13.3 GRILLE AND DIFFUSER


Supply and Install Diffuser, Grilles and Volume Damper complete with air
equalising deflector blades, plenum box (if any) and all necessary
accessories including fixing, frame and connecting to ductwork in
accordance with the technical specification and drawings, as described :-

M Supply air diffuser (SAD) ; 400x400mm no

N Supply air diffuser (SAD) ; 300x300mm no

O Supply air diffuser (SAD) ; 225x225mm no

P Supply air grille (SAG) ; 1025x150mm no

Q Supply air grille (SAG) ; 1225x125mm no

TA2459 Lesaffre Garuda 60/65 4788-3e5a-e0c9-5708-2.13


Item BILL NO. 96
96.13 HVAC WORKS Qty. Unit Rate Rupiahs
No ADMINISTRATION BUILDING

To Collection Rp. -

TA2459 Lesaffre Garuda 61/65 4788-3e5a-e0c9-5708-2.13


Item BILL NO. 96
96.13 HVAC WORKS Qty. Unit Rate Rupiahs
No ADMINISTRATION BUILDING

96.13.3 GRILLE AND DIFFUSER


Supply and Install Diffuser, Grilles and Volume Damper complete with air
equalising deflector blades, plenum box (if any) and all necessary accessories
including fixing, frame and connecting to ductwork in accordance with the
technical specification and drawings, as described :-

A Supply air grille (SAG) ; 325x125mm no

B Supply air grille (SAG) ; 225x225mm no

C Intake air louvre (IAL) ; 1000x495mm no

D Intake air louvre (IAL) ; 800x330mm no

E Intake air louvre (IAL) ; 600x330mm no

F Return air grille (RAG) ; 1200x120mm no

G Return air grille (RAG) ; 1025x125mm no

H Return air grille (RAG) ; 825x225mm no

I Exhaust air louvre (EAG) ; 1025x125mm no

J Exhaust air louvre (EAL) ; 1000x495mm no

K Exhaust air louvre (EAL) ; 800x330mm no

L Exhaust air louvre (EAL) ; 600x330mm no

M Exhaust air grille (EAG) ; 325x225mm no

N Exhaust air grille (EAG) ; 225x225mm no

96.13.4 REFRIGERANT & DRAIN PIPES


Supply and install the following Refrigerant Copper Pipeworks including
FM Approved insulation ,vapour barrier, trap, fittings (for 50mm diameter
pipe or less), joints, flanges, support and all accessories in accordance to
the technical specification and drawings, as described : -

O 6.5 mm diameter pipe copper c/w insulation m

P 9,5 mm diameter pipe copper c/w insulation m

Q 12,7 mm diameter pipe copper c/w insulation m

R 15,8 mm diameter pipe copper c/w insulation m

S 19 mm diameter pipe copper c/w insulation m

DRAIN PIPES
T 25 mm diameter pipe PVC Class AW c/w insulation m

U 32 mm diameter pipe PVC Class AW c/w insulation m

TA2459 Lesaffre Garuda 62/65 4788-3e5a-e0c9-5708-2.13


Item BILL NO. 96
96.13 HVAC WORKS Qty. Unit Rate Rupiahs
No ADMINISTRATION BUILDING

To Collection Rp. -

TA2459 Lesaffre Garuda 63/65 4788-3e5a-e0c9-5708-2.13


Item BILL NO. 96
96.13 HVAC WORKS Qty. Unit Rate Rupiahs
No ADMINISTRATION BUILDING

COLLECTIONS

Page 96.13 /1 -

Page 96.13 /2 -

Page 96.13 /3 -

Page 96.13 /4 -

Page 96.13 /5 -

Page 96.13 /6 -

Page 96.13 /7 -

96.13 HVAC WORKS


CARRIED TO SUMMARY AT END OF BILL NO. 96 Rp. -

TA2459 Lesaffre Garuda 64/65 4788-3e5a-e0c9-5708-2.13


Item BILL NO. 96
96.13 HVAC WORKS Qty. Unit Rate Rupiahs
No ADMINISTRATION BUILDING

TA2459 Lesaffre Garuda 65/65 4788-3e5a-e0c9-5708-2.13


BILL NO. 97
CANTEEN AND MUSHOLLA

TA2459 Lesaffre Garuda 1/41 8dc8-9d03-a78a-2cbb-Cover


Item BILL NO. 97 SUMMARY RUPIAHS
No. CANTEEN AND MUSHOLLA

SUMMARY

97.1 DEMOLITION N/A

97.2 EARTHWORK -

97.3 CONCRETE -

97.4 MASONRY -

97.5 METALS -

97.7 THERMAL AND MOISTURE PROTECTION -

97.8 DOORS AND WINDOWS -

97.9. FINISHES -

97.10 SPECIALITIES -

97.11 MECHANICAL WORKS -

97.12 ELECTRICAL WORKS -

97.13 HVAC WORKS -

BILL NO. 97
CARRIED TO SUMMARY -

TA2459 Lesaffre Garuda 2/41 8dc8-9d03-a78a-2cbb-Sum


Item BILL NO. 97 Qty Unit Rate Rupiahs
97.2 EARTHWORK
No. CANTEEN AND MUSHOLLA

97.2.1 EARTHWORK

Excavation, disposal and backfill in any material including rock or hard


material, working space at parimeter items as defined; Excavating, starting
from stripped level, trenches to receive depth as pecified (insite area)

A To Footings m3

B To Slab incl. ramp m3

C To Tie Beam m3

D To Column m3

97.2.2 BASE COURSES

Compacted of subgrade to 95% Standard Proctor Density as specified

E To Footings m2

F To Slab incl. ramp m2

G To Tie Beam m2

Sandfill 100mm thick as specified

H To Footings m2

I To Perimeter Slab m2

J To Tie Beam m2

Compacted gravel 200mm thick as specified

K To Slab m2

97.2.3 TERMITE CONTROL

Termite control to soil; The protection against termites by spraying an


insecticide on the soil or on the fill before placing the vapor and after
building completed and importing landfill; undertaken by an approved
specialist; (5 years quarantee to be given) as specified.

L To Footings m2

M To Slab incl. ramp m2

N To Tie Beam m2

O To Column m2

TA2459 Lesaffre Garuda 3/41 8dc8-9d03-a78a-2cbb-2.2


Item BILL NO. 97 Qty Unit Rate Rupiahs
97.2 EARTHWORK
No. CANTEEN AND MUSHOLLA

To Collection Rp. -

97.2.4 OTHERS

Plastic sheet

A To Footings m2

B To Perimeter Slab m2

C To Tie Beam m2

To Collection Rp. -

COLLECTIONS

Page 97.2/1 -

Page 97.2/2 -

TA2459 Lesaffre Garuda 4/41 8dc8-9d03-a78a-2cbb-2.2


Item BILL NO. 97 Qty Unit Rate Rupiahs
97.2 EARTHWORK
No. CANTEEN AND MUSHOLLA

97.2 EARTHWORK
CARRIED TO SUMMARY AT END OF BILL NO. 97 Rp. -

TA2459 Lesaffre Garuda 5/41 8dc8-9d03-a78a-2cbb-2.2


Item BILL NO. 97
97.3 CONCRETE Qty. Unit Rate Rupiahs
No. CANTEEN AND MUSHOLLA

97.3.1 FORMWORK

97.3.1.1 IN GROUND FORMWORK

The design, certification, construction and performance of the formwork,


falsework and backpropping shall be the responsibilty of Contractor.
Proposed method of installation and removal of formwork is to be
submitted to the Superintendent for comment prior to work being carried
out as per dwg note.
In ground formwork as follows; permanent formwork system for in-place
concrete, concrete hollow block 100mm thick, finish starting at/from any
level and including rebates or grooves formers as described to

A To Footings m2 -

B To Slab Incl. Ramp m2 -

C To Tie Beam m2 -

97.3.1.2 UPPER STRUCTURE FORMWORK

Smooth-Formed Finished concrete, plywood, metal, or other approved


panel materials, finish starting at/from any level and rebates or groove
formers as specified

D To Upper Slab m2 -

E To Beam m2 -

F To Column m2 -

G To Wall/Parapet m2 -

97.3.2 CONCRETE

In-Situ Concrete

In-situ concrete designed mix Grade 30 Mpa, (K-350) NFA; ± 20mm


aggregate, vibrated with standard flatness as described ;

H To Footings m3 -

I To Slab and Roof Incl. Ramp m3 -

J To Tie Beam and Upper Beam m3 -

K To Column m3 -

L To Wall/Parapet m3 -

Lean Concrete

Plain in-situ concrete, designed mix grade f'c= Mpa,(K-125), 40mm


aggregate, 50mm thick as described,

M To Footings m2 -

TA2459 Lesaffre Garuda 6/41 8dc8-9d03-a78a-2cbb-2.3


Item BILL NO. 97
97.3 CONCRETE Qty. Unit Rate Rupiahs
No. CANTEEN AND MUSHOLLA

To Collection Rp. -

97.3.2 CONCRETE, CONT'D

Lean Concrete

Plain in-situ concrete, designed mix grade f'c= Mpa,(K-125), 40mm


aggregate, 50mm thick as described,

A To Slab Incl. Ramp m2 -

B To Tie Beam m2 -

97.3.3 REINFORCEMENT

Manufacture reinforcement bars is according to "Manual of Standard


Practice" CRSI's as follows; supply, cleaned, measurement, positioning,
setting and install. Reinforcement measure include joint dowel bars,
bolsters, chairs, spacers and other device for spacing, supporting and
fastening reinforcing bars and welded wire reinforcement in place.

Reinforcing bars is Grade 60/420 deformed or Grade BJTD 40 deformed.


round mild steel, as described in

C Dia. 13mm, To Footings kg -

D Dia. 10mm To Slab and Roof Incl. Ramp kg -

E Dia. 25mm, To Tie Beam and Upper Beam kg -

F Dia. 22mm, To Tie Beam and Upper Beam kg -

G Dia. 19mm, To Tie Beam and Upper Beam kg -

H Dia. 16mm, To Tie Beam and Upper Beam kg -

I Dia. 10mm, To Tie Beam and Upper Beam kg -

J Dia. 19mm, To Column kg -

K Dia. 16mm, To Column kg -

L Dia. 10mm, To Column kg -

M Dia. 10mm, To Wall/Parapet kg -

97.3.4 SUNDRIES

N Insulation joint per drawings and specifications m -

O Supply and install flexible joint filler 4x25 deep sawcut, dowel 16mm m -
(round bar) ctc 300, L=300mm one side coated with bitumen per darings
and specifications (SJ)

P Supply and install polystiren 5mm thick replace by flexible joint, dowel m -
16mm (round bar) ctc 300, L=300mm one side coated with bitumen per
darings and specifications (CJ)

TA2459 Lesaffre Garuda 7/41 8dc8-9d03-a78a-2cbb-2.3


Item BILL NO. 97
97.3 CONCRETE Qty. Unit Rate Rupiahs
No. CANTEEN AND MUSHOLLA

To Collection Rp. -

COLLECTIONS

Page 97.3 /1 -

Page 97.3 /2 -

TA2459 Lesaffre Garuda 8/41 8dc8-9d03-a78a-2cbb-2.3


Item BILL NO. 97
97.3 CONCRETE Qty. Unit Rate Rupiahs
No. CANTEEN AND MUSHOLLA

97.3 CONCRETE
CARRIED TO SUMMARY AT END OF BILL NO. 97 Rp. -

TA2459 Lesaffre Garuda 9/41 8dc8-9d03-a78a-2cbb-2.3


Item BILL NO. 97
97.4 MASONRY Qty. Unit Rate Rupiahs
No CANTEEN AND MUSHOLLA

97.4.1 UNIT MASONRY

Supply and Install Autoclaved aerated concrete block wall with mortar;
including reinforced concrete bonding ties, anchorage, latching, stiffener
columns and lintels beams as required, all in accordancce with drawings
and specifications
A To Wall 150mm thick External Wall m2 -

B To Wall 150mm thick Internal Wall m2 -

97.4.2 PLASTERED

Plaster; Mortar instant trowelled smooth with and including cement coating
instant as described

C To Wall 150mm thick m2 -

97.4.3 CEILING

Supply and install calsium silicate board 6mm glued in gypsum ceiling
including ceiling suspension system and fixing accessories all in accordance
with drawings and specifications

D To Ceiling m2 -

97.4 MASONRY
CARRIED TO SUMMARY AT END OF BILL NO. 97 Rp. -

TA2459 Lesaffre Garuda 10/41 8dc8-9d03-a78a-2cbb-2.4


Item BILL NO. 97
97.4 MASONRY Qty. Unit Rate Rupiahs
No CANTEEN AND MUSHOLLA

TA2459 Lesaffre Garuda 11/41 8dc8-9d03-a78a-2cbb-2.4


Item BILL NO. 97 97.5 METALS
Qty. Unit Rate Rupiahs
No CANTEEN AND MUSHOLLA

97.5.1 STRUCTURAL FRAMING

The following in steel structure in framing sanblasting and painting


finished ; from ground level to roof floor level; comprising wide flange
bolted to mild steel, cleats, welded to rafter; including all labour,
materials and plant in fabricating,erecting with welded and bolted shop
and site connections; assembling and erecting with welded and bolted
shop and site connections; and all necessaries as specified on
specification and drawing; steel grade as note on specifications ( ASTM
A-36 / BJ 37 for steel structure)
A PR3, C150x65x20x2.3 kg -

B R2, WF200x100x5.5x8-R kg -

C SP1A, SP48.6x1.5 kg -

D TR2, Dia12-TR kg -

E SB3, WF300x150 kg -

F All connecting plates, brackets, cleats, bolts, anchor bolts and stiffeners, Ls -
welding, including sandblasting and painted finish and all necessary
fixing accessories as described

97.5 METALS

TA2459 Lesaffre Garuda 12/41 8dc8-9d03-a78a-2cbb-2.5


Item BILL NO. 97 97.5 METALS
Qty. Unit Rate Rupiahs
No CANTEEN AND MUSHOLLA

CARRIED TO SUMMARY AT END OF BILL NO. 97 Rp. -

TA2459 Lesaffre Garuda 13/41 8dc8-9d03-a78a-2cbb-2.5


Item BILL NO. 97 97.6 WOODS, PLASTICS AND Qty. Unit Rate
No CANTEEN AND MUSHOLLA COMPOSITE

97.6.1 ALUMINIUM COMPOSITE PANEL

Supply and install aluminium composite panel fire retardant core including
steel support, aluminium support, hollow support, framing, sealant, other
jointing system, and all fixing accessories as drawings and specifications

A To Canopy and Roof Parapet m2

TA2252 MBI SA 14/41 8dc8-9d03-a78a-2cbb-2.6


Item BILL NO. 97 97.6 WOODS, PLASTICS AND Qty. Unit Rate
No CANTEEN AND MUSHOLLA COMPOSITE
97.6 WOODS, PLASTICS AND COMPOSITE
CARRIED TO SUMMARY AT END OF BILL NO. 97 Rp.

TA2252 MBI SA 15/41 8dc8-9d03-a78a-2cbb-2.6


Rupiahs

TA2252 MBI SA 16/41 8dc8-9d03-a78a-2cbb-2.6


Rupiahs

TA2252 MBI SA 17/41 8dc8-9d03-a78a-2cbb-2.6


Item BILL NO. 97 97.7 THERMAL AND MOISTURE Qty Unit Rate Rupiahs
No. CANTEEN AND MUSHOLLA PROTECTION

97.7.1 ROOF SPECIALITIES

Supply and Install metal roof Klip Lok Optima 0.45 BMT finish fixed to
steel purlin including flashing, sealant, and all fixing accessories; all in
accordance with drawings and specifications

A To Canopy m2 -

97.7.2 ROOF SPECIALITIES

Supply and Install down pipe complete with overflow, steel clamp, support,
fitting, bracket, steel unp, and all fixing accessories; all in accordance with
drawings and specifications

B PVC Downpipe Ø4" m -

C Cast iron roof drain nos -

Supply and install concrete waterproofing liquid membrane complete with


accessories and support; all in accordance with manufacturer's instruction,
drawings, and specifications

D To Roof m2 -

Supply and install waterproofing membrane polyurethane complete with


accessories and support; all in accordance with manufacturer's instruction,
drawings, and specifications

E To Roof m2 -

97.7.3 SUNDRIES

F Balustrade strip as drawing and specification m -

97.7 THERMAL AND MOISTURE PROTECTION


CARRIED TO SUMMARY AT END OF BILL NO. 97 Rp. -

TA2459 Lesaffre Garuda 18/41 8dc8-9d03-a78a-2cbb-2.7


Item BILL NO. 97 97.7 THERMAL AND MOISTURE Qty Unit Rate Rupiahs
No. CANTEEN AND MUSHOLLA PROTECTION

TA2459 Lesaffre Garuda 19/41 8dc8-9d03-a78a-2cbb-2.7


Item BILL NO. 97
97.8 DOORS AND WINDOWS Qty. Unit Rate Rupiahs
No. CANTEEN AND MUSHOLLA

97.8.1 DOORS

Supply and install steel doors including frames, hardwares, treshold, steel
plate, and all necessary accessories and fixing supports as drawings and
specifications

A 97.DF.014 Size 1800x2400 nos -

B 97.DL.015 Size 1000x2400 nos -

Supply and install alumnium door including vision panel / louvre, frames,
hardwares, treshold, steel plate, and all fixing accessories and supports as
drawings and specifications

C 97.DKK.008 Size 1800x2200 nos -

D 97.DP.012 Size 1000x2200 nos -

E 97.DP.013 Size 1000x2200 nos -

F 97.DQ.002 Size 900x2200 nos -

G 97.DQ.003 Size 900x2200 nos -

H 97.DQ.004 Size 900x2200 nos -

I 97.DQ.005 Size 900x2200 nos -

J 97.DS.006 Size 1000x2200 nos -

K 97.DS.007 Size 1000x2200 nos -

L 97.DS.009 Size 1000x2200 nos -

M 97.DS.010 Size 1000x2200 nos -

Supply and install glass door including frames, hardwares, treshold, steel
plate, and all fixing accessories and supports as drawings and specifications

N 97.DT.001 Size 1800x2200 nos -

O 97.DU.011 Size 900x2150 nos -

97.8.2 WINDOWS

Supply and install aluminium fix window complete with laminated


tempered glass + clear glass, hardwares, and all necessary components,
fixing, accessories as drawing and specification.

P 97.WB.001 nos -

Q 97.WB.002 nos -

R 97.WB.003 nos -

TA2459 Lesaffre Garuda 20/41 8dc8-9d03-a78a-2cbb-2.8


Item BILL NO. 97
97.8 DOORS AND WINDOWS Qty. Unit Rate Rupiahs
No. CANTEEN AND MUSHOLLA

To Collection Rp. -

97.8.3 CURTAIN WALL

Supply and install curtain wall system complete with hardwares, and all
necessary components, fixing, accessories as drawing and specification

A 97.SV.005 nos -

B 97.SW.002 nos -

C 97.SW.003 nos -

D 97.SX.004 nos -

E 97.SY.006 nos -

F 97.SW.001 nos -

To Collection Rp. -

COLLECTIONS

Page 97.8 /1 -

Page 97.8 /2 -

TA2459 Lesaffre Garuda 21/41 8dc8-9d03-a78a-2cbb-2.8


Item BILL NO. 97
97.8 DOORS AND WINDOWS Qty. Unit Rate Rupiahs
No. CANTEEN AND MUSHOLLA

97.8 DOORS AND WINDOWS


CARRIED TO SUMMARY AT END OF BILL NO. 97 Rp. -

TA2459 Lesaffre Garuda 22/41 8dc8-9d03-a78a-2cbb-2.8


Item BILL NO. 97
97.9. FINISHES Qty. Unit Rate Rupiahs
No CANTEEN AND MUSHOLLA

97.9.1 FLOOR FINISHES

Supply and install Homogenous Tile complete with screed, gape grouting
and all in accordance with manufactured instruction applied: all in
accordance with drawings and specifications

A To Canteen and Mushola m2 -

B To External Corridor m2 -

C To Skirting m2 -

97.9.2 WALL FINISHES

Supply and install Homogenous Tile complete with screed, gape grouting
and all in accordance with manufactured instruction applied: all in
accordance with drawings and specifications

D To Toilet m2 -

Prepare smooth and apply waterbased acrylic emulsion paint finish, in


accordance with manufacturer's recommendations, as specified to face of :

E Applied to plastered autoclaved concrete walls (Internal Wall) m2 -

Prepare smooth and apply waterbased wethershield emulsion paint finish,


in accordance with manufacturer's recommendations, as specified to face of
:
F Applied to plastered autoclaved concrete walls (External Wall) m2 -

G Applied to parapet wall

Prepare smooth and apply skimcoat, in accordance with manufacturer's


recommendations, as drawing and specification

H To Exposed Concrete m2 -

97.9.3 CEILING FINISHES

Prepare smooth and apply waterbased acrylic emulsion paint finish, in


accordance with manufacturer's recommendations, as specified to face of :

I To Ceiling m2 -

97.9. FINISHES
CARRIED TO SUMMARY AT END OF BILL NO. 97 Rp. -

TA2459 Lesaffre Garuda 23/41 8dc8-9d03-a78a-2cbb-2.9


Item BILL NO. 97
97.9. FINISHES Qty. Unit Rate Rupiahs
No CANTEEN AND MUSHOLLA

TA2459 Lesaffre Garuda 24/41 8dc8-9d03-a78a-2cbb-2.9


Item BILL NO. 97
97.10 SPECIALITIES Qty. Unit Rate Rupiahs
No CANTEEN AND MUSHOLLA

97.10.1 INTERIOR SPECIALITIES

Supply and install sanitary wares complete with all necessary in


accordance with manufacturer's recommendations as drawing and
specification
A SF8, Wall Mounted tap nos -

B SF9, Toilet Cubicle nos -

C SF10, Toilet Seated nos -

D SF11, Floor Drain nos -

E SF12, Jet Shower nos -

F SF13, Urinoir nos -

G SF14, Urinal Partition nos -

H SF16, Self Closing nos -

I SF17, Under Counter Lavatory nos -

J SF18, Wall Hung Lavatory nos -

K SF19, Paper Towel Holder nos -

L SF23, Mirror Male Toilet nos -

M SF23, Mirror Female Toilet nos -

N SF23, Mirror Corridor nos -

O SF24, Soap Dispenser nos -

P SF28, Paper Towel Dispenser nos -

Q SF30, Safety Grab Rail nos -

R FU06 nos -

97.10 SPECIALITIES
CARRIED TO SUMMARY AT END OF BILL NO. 97 Rp. -

TA2459 Lesaffre Garuda 25/41 8dc8-9d03-a78a-2cbb-2.10


Item BILL NO. 97
97.11 MECHANICAL WORKS Qty. Unit Rate Rupiahs
No CANTEEN AND MUSHOLLA

97.11 MECHANICAL WORKS

97.11.1 DOMESTIC COLD WATER

DOMESTIC COLD WATER SYSTEM INSTALLATION


Supply and install Domestic Water pipes; PPR PN 10 including fittings (for 50
mm dia. Pipe or less) fixed in position complete with seals (for underground
pipe) supports, hangers, brackets, clamp, painting, and other necessary fixing
and jointing material in accordance to the technical specification and drawings,
as described;

PIPEWORKS

A 15mm diameter pipe m

B 20mm diameter pipe m

C 25mm diameter pipe m

D 32mm diameter pipe m

E 40mm diameter pipe m

F 50mm diameter pipe m

VALVE AND ANCILLARIES

G 25mm diameter gate valve no

H 32mm diameter gate valve no

I 40mm diameter gate valve no

J 50mm diameter gate valve no

K AAV; 25mm diameter no

97.11.2 SEWAGE AND WASTE WATER SYSTEM

SEWAGE AND WASTE WATER SYSTEM INSTALLATION


Supply and Install Waste water, Sewage water pipes and Venting pipes; PVC Class
AW 10 kg/m2 including fittings (for 50 mm dia. Pipe or less) fixed in position
complete with supports, hangers, brackets, clamp, painting, and other necessary
fixing and jointing material in accordance to the technical specification and
drawings, as described;

PIPEWORKS (SEWAGE AND WASTE)

L 50mm diameter pipe m

M 100mm diameter pipe m

N 150mm diameter pipe m

O 200mm diameter pipe m

TA2459 Lesaffre Garuda 26/41 8dc8-9d03-a78a-2cbb-2.11


Item BILL NO. 97
97.11 MECHANICAL WORKS Qty. Unit Rate Rupiahs
No CANTEEN AND MUSHOLLA

To Collection Rp. -

TA2459 Lesaffre Garuda 27/41 8dc8-9d03-a78a-2cbb-2.11


Item BILL NO. 97
97.11 MECHANICAL WORKS Qty. Unit Rate Rupiahs
No CANTEEN AND MUSHOLLA

97.11.2 SEWAGE AND WASTE WATER SYSTEM INSTALLATION (Cont'd)


Supply and Install Waste water, Sewage water pipes and Venting pipes; PVC Class
AW 10 kg/m2 including fittings (for 50 mm dia. Pipe or less) fixed in position
complete with supports, hangers, brackets, clamp, painting, and other necessary
fixing and jointing material in accordance to the technical specification and
drawings, as described;

PIPEWORKS (VENTING)

A 40mm diameter pipe m

B 50mm diameter pipe m

FITTINGS

C Fitting 100mm diameter no

D Fitting 150mm diameter no

E Fitting 200mm diameter no

VALVE AND ANCILLARIES

F Ventcap 50mm diameter no

G Clean out 50mm diameter no

H Clean out 100mm diameter no

97.11.3 HYDRANT & SPRINKLER SYSTEM

VALVE AND ANCILLARIES

I Portable fire extinguisher with capacity 4.5 kg chemical powder ABC type. no

J Portable fire extinguisher with capacity 6 kg chemical powder C02 type. no

To Collection Rp. -

COLLECTION

Page 97.11 /1 -

Page 97.11 /2 -

97.11 MECHANICAL WORKS


CARRIED TO SUMMARY AT END OF BILL NO. 97 Rp. -

TA2459 Lesaffre Garuda 28/41 8dc8-9d03-a78a-2cbb-2.11


Item BILL NO. 97
97.11 MECHANICAL WORKS Qty. Unit Rate Rupiahs
No CANTEEN AND MUSHOLLA

TA2459 Lesaffre Garuda 29/41 8dc8-9d03-a78a-2cbb-2.11


Item BILL NO. 97
97.12 ELECTRICAL WORKS Qty. Unit Rate Rupiahs
No CANTEEN AND MUSHOLLA

97.12 ELECTRICAL WORKS

97.12.1 SUB DISTRIBUTION BOARDS


Supply, Install and Testing Commissioning the following Sub Distribution board
fix in position includes circuit breaker, board, busbar, digital multimeter,
contactor, surge arrester, potensial transformer, current transformer, indicator
lamp, fuse, loto, star / stop push button, and all necessary accessories in
arcondance to the technical spesification as shown on drawing, as described : -

A 97DB01 no

97.12.2 MAIN AND SUB-MAINS CABLES


Supply and Install the following Main and Sub-Mains circuit distribution cable
run & fixed on cable tray/ladders including all necessary accessories in
arcondance to the technical spesification as shown on drawing, as described : -

B From SDB…. to 97DB01 m by other package

97.12.3 LIGHTING FIXTURES & POWER OUTLET


Supply and Install the following light fittings including tubes or lamps fixed in
position complete with all accessories and support in accordance with the
technical specification and drawings, as described :-

C Recessed mounted TLED 40W, 220V, 3709 lm no

D Recessed mounted TLED 40W, 220V, 3709 lm, c/w nicad battery duration 1 no
hour

E Exit sign LED 5W, 220V, wall mounted no

F Waterproof LED 20W, 220V, IP65, 2000 lm, L600 no

G Waterproof LED 20W, 220V, IP65, 2000 lm, L600, c/w nicad battery duration 1 no
hour

H Downlight 16W, 220V, minimum 1200 lm no

I Downlight 16W, 220V, minimum 1200 lm, c/w nicad battery duration 1 hour no

J Surface downlight 16W, 220V, minimum 1200 lm no

K Surface downlight 16W, 220V, minimum 1200 lm, c/w nicad battery duration 1 no
hour

Supply and Install the following switches including provision of steel/metal box
and all accessories accordance with the technical specification and drawings, as
described :-

L Single gang, 1 way switch, 10A no

M Double gang, 1 way switch, 10A no

To Collection Rp. -

TA2459 Lesaffre Garuda 30/41 8dc8-9d03-a78a-2cbb-2.12


Item BILL NO. 97
97.12 ELECTRICAL WORKS Qty. Unit Rate Rupiahs
No CANTEEN AND MUSHOLLA

TA2459 Lesaffre Garuda 31/41 8dc8-9d03-a78a-2cbb-2.12


Item BILL NO. 97
97.12 ELECTRICAL WORKS Qty. Unit Rate Rupiahs
No CANTEEN AND MUSHOLLA

97.12.3 LIGHTING FIXTURES & POWER OUTLET (Cont'd)


Supply and Install lighting & switch cables from sub circuit to final circuit
including grounding system and all neccessary accessories accordance with the
technical specification and drawings, as described :-

A Cabling point from local panel (500V/CU/PVC 3C x 2.5 mm² shall be UV & no
chemical resistance) run-in and with PVC high impact conduit) to; lighting and
switch

POWER OUTLET
Supply and Install the following power outlet including provision of steel/metal
box and all accessories accordance with the Technical Specification and
drawings, as described :-

B General socket outlet, wall mounted, 16A, 250V, single gang no

C General socket outlet hand dryer, wall mounted, 16A, 250V, (waterproof) single no
gang

97.12.4 TRAYS AND LADDERS


Supply and Install hot dip galvanized tray and ladder 2mm thickness include
jointing, elbow, tee, fixing accessories and hangers and all necessary accessories
accordance with the technical specification and drawings, as described :-

Electrical
D Cable tray 300x100mm m

Electronic
E Cable tray 200x100mm m

97.12.5 GROUNDING & LIGHTNING PROTECTION SYSTEM


Supply and Install Grounding system for panel and equipment complete with
support and all neccessary accessories accordance with the technical
specification and drawings, as described :-

F Earth pit, Conductor clamp and rod electrode, dia 19mm x 3000 length no

G Earthing bonding bar (copper bar) 50x3mm thk, c/w isolator no

H BC 70mm2, grounding cable for main/mesh earthing c/w connector and m


grounding lug

I Potential earth clamp (100kA) no

J Bonding cable NYAF 16mm2 m

K Bonding cable NYAF 35mm2 m

To Collection Rp. -

TA2459 Lesaffre Garuda 32/41 8dc8-9d03-a78a-2cbb-2.12


Item BILL NO. 97
97.12 ELECTRICAL WORKS Qty. Unit Rate Rupiahs
No CANTEEN AND MUSHOLLA

TA2459 Lesaffre Garuda 33/41 8dc8-9d03-a78a-2cbb-2.12


Item BILL NO. 97
97.12 ELECTRICAL WORKS Qty. Unit Rate Rupiahs
No CANTEEN AND MUSHOLLA

97.12.6 FIRE ALARM


Supply and Install the following Fire Alarm Equipment complete with support, and
all necessary accessories in accordance to the technical specification and
drawings, as described : -

A JBFA-97-01 no

B Addressable photoelectric smoke detector no

C Addressable fixed heat detector no

D Addressable manual call point no

E Horn & strobe light no

F End of line (EOL) no

Supply and Install the following Fire Alarm cables in final sub-circuit to
termination, run-in and with steel conduit 20mm dia; including earthing system
and all necessary accessories in accordance to the technical spesification as
shown on drawing, as described : -

G Power Cable FRC 2Cx2,5 mm2; from control room BD50 m

H Cable FRC STP 2Cx1,5 mm2; for detector point no

I Cable FRC STP 2Cx1,5 mm2; for manual call point no

J Cable FRC 2Cx1,5 mm2; for horn & strobe light point no

97.12.7 PUBLIC ADDRESS


Supply and Install the following Sound System Equipment complete with support,
and all necessary accessories in accordance to the technical specification and
drawings, as described : -

K Wall mounted switch rack JBPA-92-01 (SR-92-01) no

L Indoor ceiling mounted speaker 6W no

M Column speaker 10W no

Supply and Install the following Public Address cables in final sub-circuit to
termination, run-in and with steel conduit 20mm dia; including earthing system
and all necessary accessories in accordance to the technical spesification as
shown on drawing, as described : -

N Cable FO OM3; from BD96 m

O Cable NYMHY 2Cx1,5 mm2; for indor ceiling speaker point no

P Cable NYMHY 2Cx1,5 mm2; for column speaker point no

To Collection Rp. -

TA2459 Lesaffre Garuda 34/41 8dc8-9d03-a78a-2cbb-2.12


Item BILL NO. 97
97.12 ELECTRICAL WORKS Qty. Unit Rate Rupiahs
No CANTEEN AND MUSHOLLA

TA2459 Lesaffre Garuda 35/41 8dc8-9d03-a78a-2cbb-2.12


Item BILL NO. 97
97.12 ELECTRICAL WORKS Qty. Unit Rate Rupiahs
No CANTEEN AND MUSHOLLA

97.12.8 DATA AND TELEPHONE


Supply and Install the following Data and Communication System
Equipment complete with support, and all necessary accessories in
accordance to the technical specification and drawings, as described : -

A Single gang type data outlet (RJ45) no

B Single gang type telephone outlet (RJ45) no

Supply and Install the following Data and Telephone cables in final sub-circuit
to termination, run-in and with steel conduit 20mm dia; including earthing system
and all necessary accessories in accordance to the technical spesification as
shown on drawing, as described : -

C Cable UTP-CAT6/FO mm2; for data outlet point no

D Cable UTP-CAT6/FO mm2; for data outlet point no

E Cable UTP-CAT6/FO mm2; for telephone outlet point no

To Collection Rp. -

COLLECTIONS

Page 97.12 /1 -

Page 97.12 /2 -

Page 97.12 /3 -

Page 97.12 /4 -

97.12 ELECTRICAL WORKS


CARRIED TO SUMMARY AT END OF BILL NO. 97 Rp. -

TA2459 Lesaffre Garuda 36/41 8dc8-9d03-a78a-2cbb-2.12


Item BILL NO. 97
97.12 ELECTRICAL WORKS Qty. Unit Rate Rupiahs
No CANTEEN AND MUSHOLLA

TA2459 Lesaffre Garuda 37/41 8dc8-9d03-a78a-2cbb-2.12


Item BILL NO. 97
97.13 HVAC WORKS Qty. Unit Rate Rupiahs
No CANTEEN AND MUSHOLLA

97.13 HVAC WORKS

97.13.1 EQUIPMENT

DX UNIT

Supply and Install of DX Units complete with hangers/supports, vibration


mountings, neoprene pads and all necessary accessories in accordance to
the technical specification and drawings, as described : -

A IU-DX.97.00.01; wall mounted, cooling capacity 5.8kWth, supply no


air flow 858 CMH, 0.1kW, 220V/1Ph/50Hz

B OU-DX.97.00.01; air cooled inverter, cooling capacity 5.8kWth, supply no


air flow 858 CMH, 0.1kW, 220V/1Ph/50Hz

FAN

Supply and Install of Fan Units complete with hangers/supports, vibration


mountings, neoprene pads and all necessary accessories in accordance to the
technical specification and drawings, as described : -

C Exhaust Fan EF-97.00.01, axial wall mounted type, cap 627 CMH, static no
pressure 93 pa, 0.37kW, 220V/1Ph/50Hz

D Exhaust Fan EF-97.00.02, axial wall mounted type, cap 249-400 CMH, static no
pressure 20 pa, 0.37kW, 220V/1Ph/50Hz

E Exhaust Fan EF-97.00.03, axial wall mounted type, cap 261-400 CMH, static no
pressure 20 pa, 0.37kW, 220V/1Ph/50Hz

F Exhaust Fan EF-97.00.04, axial wall mounted type, cap 261-400 CMH, static no
pressure 20 pa, 0.37kW, 220V/1Ph/50Hz

G Ceiling Fan CF-97.00.01A, cap 14220 CMH, free blow, 0.37kW, no


220V/1Ph/50Hz

H Ceiling Fan CF-97.00.01B, cap 14220 CMH, free blow, 0.37kW, no


220V/1Ph/50Hz

I Ceiling Fan CF-97.00.02, cap 14220 CMH, free blow, 0.37kW, no


220V/1Ph/50Hz

97.13.2 DUCTWORK

Supply and Install galvanized steel sheet ductworks complete with


hangers, supports, brackets and all necessary fixing accessories in
accordance to the technical tpecification and drawings, as described :-

EXHAUST AIR DUCT

With external insulation (closed cell elastomeric fire retardant type class 0,
FM Approved, 25mm thickness + AL sheet Jacketing 0.4mm thckness)

J Exhaust air duct (EAD) ; 300x300mm m

TA2459 Lesaffre Garuda 38/41 8dc8-9d03-a78a-2cbb-2.13


Item BILL NO. 97
97.13 HVAC WORKS Qty. Unit Rate Rupiahs
No CANTEEN AND MUSHOLLA

To Collection Rp. -

TA2459 Lesaffre Garuda 39/41 8dc8-9d03-a78a-2cbb-2.13


Item BILL NO. 97
97.13 HVAC WORKS Qty. Unit Rate Rupiahs
No CANTEEN AND MUSHOLLA

97.13.3 GRILLE AND DIFFUSER

Supply and Install Diffuser, Grilles and Volume Damper complete with air
equalising deflector blades, plenum box (if any) and all necessary
accessories including fixing, frame and connecting to ductwork in
accordance with the technical specification and drawings, as described :-

A Supply air grille (SAG) ; 400x400mm no

B Exhaust air louvre (EAL) ; 600x330mm no

97.13.2 REFRIGERANT & DRAIN PIPES

Supply and install the following Refrigerant Copper Pipeworks including


FM Approved insulation ,vapour barrier, trap, fittings (for 50mm diameter
pipe or less), joints, flanges, support and all accessories in accordance to
the technical specification and drawings, as described : -

C 6.5 mm diameter pipe copper c/w insulation m

D 9,5 mm diameter pipe copper c/w insulation m

E 12,7 mm diameter pipe copper c/w insulation m

DRAIN PIPES

F 25 mm diameter pipe PVC Class AW c/w insulation m

To Collection Rp. -

COLLECTIONS

Page 97.13 /1 -

Page 97.13 /2 -

TA2459 Lesaffre Garuda 40/41 8dc8-9d03-a78a-2cbb-2.13


Item BILL NO. 97
97.13 HVAC WORKS Qty. Unit Rate Rupiahs
No CANTEEN AND MUSHOLLA

97.13 HVAC WORKS


CARRIED TO SUMMARY AT END OF BILL NO. 97 Rp. -

TA2459 Lesaffre Garuda 41/41 8dc8-9d03-a78a-2cbb-2.13


BILL NO. 99
PIPE BRIDGE

TA2459 Lesaffre Garuda 1/23 5460-24ef-5f03-0b25-Cover


Item BILL NO. 99 SUMMARY RUPIAHS
No. PIPE BRIDGE

SUMMARY

99.1 DEMOLITION N/A

99.2 EARTHWORK -

99.3 CONCRETE -

99.4 MASONRY N/A

99.5 METALS -

99.7 THERMAL AND MOISTURE PROTECTION N/A

99.8 DOORS AND WINDOWS N/A

99.9. FINISHES N/A

99.10 SPECIALITIES N/A

99.11 MECHANICAL WORKS N/A

99.2 ELECTRICAL WORKS N/A

99.3 HVAC WORKS N/A

BILL NO. 99
CARRIED TO SUMMARY -

TA2459 Lesaffre Garuda 2/23 5460-24ef-5f03-0b25-Sum


Item BILL NO. 99 Qty Unit Rate Rupiahs
99.2 EARTHWORK
No. PIPE BRIDGE

99.2.1 CUT OFF PILE HEAD

Cut off pile head as drawings

A Spun pile, dia. 400mm nos

99.2.2 EARTHWORK

Excavation, disposal and backfill in any material including rock or hard


material, working space at parimeter items as defined; Excavating, starting
from stripped level, trenches to receive depth as pecified (insite area)

B To Pile Caps m3

C To Tie Beam m3

D To Pedestal m3

99.2.3 BASE COURSES

Compacted of subgrade to 95% Standard Proctor Density as specified

E To Pile Caps m2

F To Tie Beam m2

Sandfill 100mm thick as specified

G To Pile Caps m2

H To Tie Beam m2

99.2.4 TERMITE CONTROL

Termite control to soil; The protection against termites by spraying an


insecticide on the soil or on the fill before placing the vapor and after
building completed and importing landfill; undertaken by an approved
specialist; (5 years quarantee to be given) as specified.

I To Pile Caps m2

J To Tie Beam m2

K To Pedestal m2

99.2.5 OTHERS

Plastic sheet

L To Pile Caps m2

M To Tie Beam m2

99.2 EARTHWORK

TA2459 Lesaffre Garuda 3/23 5460-24ef-5f03-0b25-2.2


Item BILL NO. 99 Qty Unit Rate Rupiahs
99.2 EARTHWORK
No. PIPE BRIDGE

CARRIED TO SUMMARY AT END OF BILL NO. 99 Rp. -

TA2459 Lesaffre Garuda 4/23 5460-24ef-5f03-0b25-2.2


Item BILL NO. 99
99.3 CONCRETE Qty. Unit Rate Rupiahs
No. PIPE BRIDGE

99.3.1 FORMWORK

99.3.1.1 IN GROUND FORMWORK

The design, certification, construction and performance of the formwork,


falsework and backpropping shall be the responsibilty of Contractor.
Proposed method of installation and removal of formwork is to be
submitted to the Superintendent for comment prior to work being carried
out as per dwg note.
In ground formwork as follows; permanent formwork system for in-place
concrete, concrete hollow block 100mm thick, finish starting at/from any
level and including rebates or grooves formers as described to

A To Pile Caps m2 -

B To Tie Beam m2 -

99.3.1.2 UPPER STRUCTURE FORMWORK

Smooth-Formed Finished concrete, plywood, metal, or other approved


panel materials, finish starting at/from any level and rebates or groove
formers as specified

C To Pedestal m2 -

99.3.2 CONCRETE

In-Situ Concrete

In-situ concrete designed mix Grade 25 Mpa, (K-300) NFA; ± 20mm


aggregate, vibrated with standard flatness as described ;

D To Pile Caps m3 -

E To Tie Beam m3 -

F To Pedestal m3 -

Lean Concrete

Plain in-situ concrete, designed mix grade f'c= Mpa,(K-125), 40mm


aggregate, 50mm thick as described,

G To Pile Caps m2 -

H To Tie Beam m2 -

99.3.3 REINFORCEMENT

Manufacture reinforcement bars is according to "Manual of Standard


Practice" CRSI's as follows; supply, cleaned, measurement, positioning,
setting and install. Reinforcement measure include joint dowel bars,
bolsters, chairs, spacers and other device for spacing, supporting and
fastening reinforcing bars and welded wire reinforcement in place.

Reinforcing bars is Grade 60/420 deformed or Grade BJTD 40 deformed.


round mild steel, as described in

I Dia. 13mm, To Pile Caps kg -

TA2459 Lesaffre Garuda 5/23 5460-24ef-5f03-0b25-2.3


Item BILL NO. 99
99.3 CONCRETE Qty. Unit Rate Rupiahs
No. PIPE BRIDGE

To Collection Rp. -

99.3.3 REINFORCEMENT, CONT'D

Reinforcing bars is Grade 60/420 deformed or Grade BJTD 40 deformed.


round mild steel, as described in

A Dia. ..mm, To Footings and Pile Caps kg -

B Dia. 16mm, To Tie Beam kg -

C Dia. 10mm, To Tie Beam kg -

D Dia. 16mm, To Pedestal kg -

E Dia. 10mm, To Pedestal kg -

To Collection Rp. -

COLLECTIONS

Page 96.3 /1 -

Page 96.3 /2 -

TA2459 Lesaffre Garuda 6/23 5460-24ef-5f03-0b25-2.3


Item BILL NO. 99
99.3 CONCRETE Qty. Unit Rate Rupiahs
No. PIPE BRIDGE

99.3 CONCRETE
CARRIED TO SUMMARY AT END OF BILL NO. 99 Rp. -

TA2459 Lesaffre Garuda 7/23 5460-24ef-5f03-0b25-2.3


Item BILL NO. 99
99.4 MASONRY Qty. Unit Rate Rupiahs
No PIPE BRIDGE

99.4 MASONRY
CARRIED TO SUMMARY AT END OF BILL NO. 99 Rp. N/A

TA2459 Lesaffre Garuda 8/23 5460-24ef-5f03-0b25-2.4


Item BILL NO. 99
99.4 MASONRY Qty. Unit Rate Rupiahs
No PIPE BRIDGE

TA2459 Lesaffre Garuda 9/23 5460-24ef-5f03-0b25-2.4


Item BILL NO. 99 99.5 METALS
Qty. Unit Rate Rupiahs
No PIPE BRIDGE

99.5.1 STRUCTURAL FRAMING

The following in steel structure in framing sanblasting and painting


finished ; from ground level to roof floor level; comprising wide flange
bolted to mild steel, cleats, welded to rafter; including all labour,
materials and plant in fabricating,erecting with welded and bolted shop
and site connections; assembling and erecting with welded and bolted
shop and site connections; and all necessaries as specified on
specification and drawing; steel grade as note on specifications ( ASTM
A-36 / BJ 37 for steel structure)
A SC2, WF150x150x7x10 kg -

B SC4, WF200x200x8x12 kg -

C SC6, WF250x250x9x14 kg -

D SC8, WF300x300x10x15 kg -

E SC19, UNP150x75x6.5x10 kg -

F SC20A, UNP180x75x7x10.5 kg -

G SC21, UNP200x80x7.5x11 kg -

H HB2, L50x50x0x5 kg -

I HB3, L75x75x0x6 kg -

J HB4A, L90x90x0x7 kg -

K HB5, L100x100x0x7 kg -

L SB3, WF250x125x6x9-SB kg -

M SB11, UNP125x65x6x8 kg -

N SB12A, UNP180x75-SB kg -

O SB13, UNP200x80x7.5x11 kg -

P SB16, L50x50x0x6 kg -

Q SG2, WF200x100x5.5x8 kg -

R SG3, WF250x125x6x9 kg -

S SG4, WF300x150x6.5x9 kg -

T SG5, WF350x175x7x11 kg -

U SG6, WF400x200x8x13 kg -

V SG13, UNP200x80x7.5x11 kg -

W VB2, L50x50x0x5 kg -

X VB3, L75x75x0x6 kg -

TA2459 Lesaffre Garuda 10/23 5460-24ef-5f03-0b25-2.5


Item BILL NO. 99 99.5 METALS
Qty. Unit Rate Rupiahs
No PIPE BRIDGE

To Collection Rp. -

99.5.1 STRUCTURAL FRAMING, CONT'D

The following in steel structure in framing sanblasting and painting


finished ; from ground level to roof floor level; comprising wide flange
bolted to mild steel, cleats, welded to rafter; including all labour,
materials and plant in fabricating,erecting with welded and bolted shop
and site connections; assembling and erecting with welded and bolted
shop and site connections; and all necessaries as specified on
specification and drawing; steel grade as note on specifications ( ASTM
A-36 / BJ 37 for steel structure)
A VB3A, L75x75x0x9 kg -

B All connecting plates, brackets, cleats, bolts, anchor bolts and stiffeners, Ls -
welding, including sandblasting and painted finish and all necessary
fixing accessories as described

To Collection Rp. -

COLLECTIONS

Page 99.5 / 1 -

Page 99.5 / 1 -

99.5 METALS

TA2459 Lesaffre Garuda 11/23 5460-24ef-5f03-0b25-2.5


Item BILL NO. 99 99.5 METALS
Qty. Unit Rate Rupiahs
No PIPE BRIDGE

CARRIED TO SUMMARY AT END OF BILL NO. 99 Rp. -

TA2459 Lesaffre Garuda 12/23 5460-24ef-5f03-0b25-2.5


Item BILL NO. 99 99.7 THERMAL AND MOISTURE Qty Unit Rate Rupiahs
No. PIPE BRIDGE PROTECTION

99.7 THERMAL AND MOISTURE PROTECTION


CARRIED TO SUMMARY AT END OF BILL NO. 99 Rp. N/A

TA2459 Lesaffre Garuda 13/23 5460-24ef-5f03-0b25-2.7


Item BILL NO. 99 99.7 THERMAL AND MOISTURE Qty Unit Rate Rupiahs
No. PIPE BRIDGE PROTECTION

TA2459 Lesaffre Garuda 14/23 5460-24ef-5f03-0b25-2.7


Item BILL NO. 99
99.8 DOORS AND WINDOWS Qty. Unit Rate Rupiahs
No. PIPE BRIDGE

99.8 DOORS AND WINDOWS


CARRIED TO SUMMARY AT END OF BILL NO. 99 Rp. N/A

TA2459 Lesaffre Garuda 15/23 5460-24ef-5f03-0b25-2.8


Item BILL NO. 99
99.9. FINISHES Qty. Unit Rate Rupiahs
No PIPE BRIDGE

99.9. FINISHES
CARRIED TO SUMMARY AT END OF BILL NO. 99 Rp. N/A

TA2459 Lesaffre Garuda 16/23 5460-24ef-5f03-0b25-2.9


Item BILL NO. 99
99.9. FINISHES Qty. Unit Rate Rupiahs
No PIPE BRIDGE

TA2459 Lesaffre Garuda 17/23 5460-24ef-5f03-0b25-2.9


Item BILL NO. 99
99.10 SPECIALITIES Qty. Unit Rate Rupiahs
No PIPE BRIDGE

99.10 SPECIALITIES
CARRIED TO SUMMARY AT END OF BILL NO. 99 Rp. N/A

TA2459 Lesaffre Garuda 18/23 5460-24ef-5f03-0b25-2.10


Item BILL NO. 99
99.11 MECHANICAL WORKS Qty. Unit Rate Rupiahs
No PIPE BRIDGE

99.11 MECHANICAL WORKS


CARRIED TO SUMMARY AT END OF BILL NO. 99 Rp. N/A

TA2459 Lesaffre Garuda 19/23 5460-24ef-5f03-0b25-2.11


Item BILL NO. 99
99.11 MECHANICAL WORKS Qty. Unit Rate Rupiahs
No PIPE BRIDGE

TA2459 Lesaffre Garuda 20/23 5460-24ef-5f03-0b25-2.11


Item BILL NO. 99
99.2 ELECTRICAL WORKS Qty. Unit Rate Rupiahs
No PIPE BRIDGE

99.2 ELECTRICAL WORKS


CARRIED TO SUMMARY AT END OF BILL NO. 99 Rp. N/A

TA2459 Lesaffre Garuda 21/23 5460-24ef-5f03-0b25-2.12


Item BILL NO. 99
99.2 ELECTRICAL WORKS Qty. Unit Rate Rupiahs
No PIPE BRIDGE

TA2459 Lesaffre Garuda 22/23 5460-24ef-5f03-0b25-2.12


Item BILL NO. 99
99.3 HVAC WORKS Qty. Unit Rate Rupiahs
No PIPE BRIDGE

99.3 HVAC WORKS


CARRIED TO SUMMARY AT END OF BILL NO. 99 Rp. N/A

TA2459 Lesaffre Garuda 23/23 5460-24ef-5f03-0b25-2.13

You might also like