Professional Documents
Culture Documents
Utilities
Root Guard
The Company intends to lead the market in the design and manufacture of innovative
geosynthetics, and continue to provide ground-breaking solutions - the next generation
of Terram products.
3
Root Guard
Protectamesh™HD Rockshield
Pipe protection mesh
Protectamesh™ HD is essential where pipelines are Protectamesh™ HD protects the pipes anti-corrosion coating.
constructed through rocky terrain.
4
Root Guard
Protectamesh™ used to protect the pipeline from the Protectamesh™ absorbs any movement between the
concrete saddle weights. pipe and the concrete saddles.
Available in black
or yellow
Lightweight
Cost effective
Manufactured to withstand
extreme weather conditions,
hot to cold
Protects pipe coating from
protruding rocks
Available in rolls or pads
Minimises abrasion of
coating from pipe
Protectamesh ™
movement underground
HD is flexible even
at sub-zero
temperatures
PRODUCT DETAILS
UNIT WEIGHT APERTURE
WIDTH THICKNESS COLOUR
g/m2 lb/ft2 (Diamond structure)
1.22m (4ft) 10mm (0.40”) 1500 0.32 Black 4mm x 4mm (0.16” x 0.16”)
1.22m (4ft) 10mm (0.40”) 1500 0.32 Yellow 4mm x 4mm (0.16” x 0.16”)
1.53m (5ft) 10mm (0.40”) 1500 0.32 Black 4mm x 4mm (0.16” x 0.16”)
1.53m (5ft) 10mm (0.40”) 1500 0.32 Yellow 4mm x 4mm (0.16” x 0.16”)
1.83m (6ft) 10mm (0.40”) 1500 0.32 Black 4mm x 4mm (0.16” x 0.16”)
1.83m (6ft) 10mm (0.40”) 1500 0.32 Yellow 4mm x 4mm (0.16” x 0.16”)
5
Root Guard
Rockshield
Pipe protection mesh
Rockshield meshes are manufactured from high density The polyethylene mesh can incorporate a blowing agent to
polyethylene, and are designed to act as a shield against produce a strong cellular cushioning structure offering
impact damage from rocks during backfilling, ensuring the maximum protection against rock impact damage during
protective coatings on the pipes are not damaged. backfilling operations and protruding rocks in the trench.
Rockshield meshes can be used where metallic pipes are Chemically inert, the mesh will not rot and the open mesh
installed in rocky terrain, or in areas where soil movement structure allows water to flow around the pipe ensuring
is a possibility. cathodic protection is not affected.
Various grades of mesh are offered to produce a range
High resistance to compression, tearing of solutions to meet the most demanding conditions.
and wearing A wide range of alternative grades can be manufactured
Adaptable to all pipeline sizes to your specification subject to a minimum order
quantity. Rockshield mesh can be manufactured in
Chemically inert
various roll sizes and cut pieces, with widths up to 2.5m
Light, flexible and easy to install in wide and in various lengths. Custom mesh structures
3 different ways and roll sizes can be manufactured to suit individual
Durable without the loss of the cushioning requirements subject to minimum order quantities.
characteristics
Unaffected by temperature extremes and
wet weather
Maintains cathodic protection without inhibiting
cathodic flow
Technical Specifications
Roll Size Roll Size Unit Weight Max pipe diameter for
Product Colour
(m) (feet) g/m2 lb/ft2 longitudinal wrapping
BRS 1, 2 1.5 x 20 4.9 x 65.6 750, 950, 1200 0.154, 0.195, 0.246 Black 430mm 16.9 in.
BRS 3 1.0 x 20 3.28 x 65.6 1200 0.246 Black 270mm 10.6 in.
BRS 5, 6, 7 2.0 x 24 6.5 x 78.7 1200, 950, 750 0.246, 0.195, 0.154 Black 585mm 23 in.
BRS 11 1.0 x 30 3.28 x 98.4 600 0.123 Black 270mm 10.6 in.
BRS 12 1.54 x 30.48 5 x 100 560 0.115 Black 440mm 17.3 in.
BRS 13 1.84 x 30.48 6 x 100 560 0.115 Black 535mm 21 in.
BRS 15 1.65 x 20 5.4 x 65.6 950 0.195 Black 475mm 18.7 in.
6
Root Guard
Rockshield
Application Diagram
PADS
Custom cut pads should be wrapped around the
circumference of the pipe, covering all exposed
Section View
areas. Ensure that all pads are of sufficient
dimension to protect the entire pipe.
All pad overlaps shall be placed at the 6 o’clock
position of the pipe, taking care to secure
the PROTECTAMESH with a polypropylene banding.
Place all end to end overlaps min. 50mm/ 2”; all
parallel pad overlaps min.150mm/ 6”.
All pads shall be secured to the pipe by using a min.
18mm/ 0.7” wide polypropylene banding.
After pads are secured to the pipe, the backfill
process may take place.
ROLLS
All rolls should be of adequate coverage to entirely cover the circumference of the pipe.
PROTECTAMESH is to be placed around pipe, whereby placing overlap portion at the 6 o’clock
position of the pipe.
Place all end to end overlaps min. 50mm/ 2”; all parallel pad overlaps min 150mm/ 6”.
In the event that a side overlap is used place the overlaps “shingle style”. This will ensure that no backfill will protrude under
the PROTECTAMESH
After pads are secured to the pipe, the backfill process may take place.
7
Root Guard
Utilitape ™
Underground Warning Tape
Utilitape™ is the most economical way of warning Premium & Economy grades available
excavators of buried services below ground. Our tapes Material - High quality linear low density
can be printed with any text in any language, any colour polyethylene.
and any size, manufactured to your specifications. Lead free pigments with virgin grade film.
Standard texts are available ex-stock. Soil tolerance from-pH 2.5 to pH 11.0 inclusive
Premium grade manufactured in accordance
with ENATS 12-23 Issue 2 : 2004
Various thicknesses of polyethylene available.
Technical Specifications
TEXT/COLOURS SIZE PART No. TEXT/COLOURS SIZE PART No.
PREMIUM GRADE
CAUTION CAUTION CAUTION 150mm x 0.1mm x 365mtrs 004126 CAUTION CAUTION CAUTION 150mm x 0.1mm x 365mtrs 004805
WATER PIPE BELOW TELEPHONE CABLE BELOW
150mm x 0.1mm x 365mtrs 002146 CAUTION CAUTION CAUTION 150mm x 0.1mm x 365mtrs 002405
ROAD DUCT BELOW
CAUTION CAUTION CAUTION 150mm x 0.1mm x 365mtrs 002467 CAUTION CAUTION CAUTION 150mm x 0.1mm x 365mtrs 006045
GAS MAIN BELOW TRAFFIC SIGNAL CABLE BELOW
CAUTION CAUTION CAUTION
STREET LIGHTING CABLE BELOW 150mm x 0.1mm x 365mtrs 002344 FIN DRAIN 150mm x 0.1mm x 365mtrs 004928
CAUTION CAUTION CAUTION 150mm x 0.1mm x 365mtrs 006168 150mm x 0.1mm x 365mtrs 003662
STREET LIGHTING CABLE BELOW CAUTION•ELECTRIC CABLE BELOW
CAUTION CAUTION CAUTION 150mm x 0.1mm x 365mtrs 005468 CAUTION CAUTION CAUTION 150mm x 0.1mm x 365mtrs 005161
FOUL SEWER BELOW CCTV CABLE BELOW
CAUTION CAUTION CAUTION 150mm x 0.1mm x 365mtrs 005444 CAUTION CAUTION CAUTION 150mm x 0.1mm x 365mtrs 005482
SEWERAGE PUMPING MAIN BELOW OIL PIPELINE BELOW
CAUTION CAUTION CAUTION 150mm x 0.1mm x 365mtrs 004867
FIBRE OPTIC CABLES
ECONOMY GRADE
CAUTION CAUTION CAUTION 150mm x 0.05mm x 365mtrs 004102 CAUTION CAUTION CAUTION 150mm x 0.05mm x 365mtrs 004843
WATER PIPE BELOW FIBRE OPTIC CABLES
CAUTION CAUTION CAUTION 150mm x 0.05mm x 365mtrs 002047 CAUTION CAUTION CAUTION 150mm x 0.05mm x 365mtrs 004782
ELECTRIC CABLE BELOW TELEPHONE CABLE BELOW
CAUTION CAUTION CAUTION 150mm x 0.05mm x 365mtrs 002443 CAUTION CAUTION CAUTION 150mm x 0.05mm x 365mtrs 006144
GAS MAIN BELOW STREET LIGHTING CABLE BELOW
CAUTION CAUTION CAUTION 150mm x 0.05mm x 365mtrs 002320 CAUTION CAUTION CAUTION 150mm x 0.05mm x 365mtrs 045006
STREET LIGHTING CABLE BELOW FOUL SEWER BELOW
8
Root Guard
Utilitnet ™
Underground Warning Mesh
Technical Specifications
PRODUCT TEXT/COLOUR SIZE MATERIAL PART NO.
CAUTION - ELECTRIC CABLE BELOW 150mm x 365mtrs PPH 003648
CAUTION - WATER MAIN BELOW 150mm x 365mtrs PPH 050925
CAUTION - GAS MAIN BELOW 150mm x 365mtrs PPH 050932
CAUTION - FOUL SEWER BELOW 150mm x 365mtrs PPH 050949
CAUTION - FIBRE OPTIC CABLE BELOW 150mm x 365mtrs PPH 050956
EUROPEAN STANDARD
BS EN 12613:2009 is a European wide directive that specifies the
warning characteristics for all underground warning devices.
This scope covers electric cables and pipelines containing
pressurised or non-pressurised fluids.
Underground Warning mesh is manufactured to the European
In-house
Standard and has been independently tested and approved. Our
laboratory
own in-house crate test and laboratory ensure consistent quality crate test to
conform to
and standards are maintained to conform to BS EN 12613:2009.
BS EN 12613:2009
Copies of test reports are available.
9
Root Guard
Wavelay ®
Detectable Tape
Wavelay® is a highly visible and detectable warning tape. Rust free stainless Clear PE film
steel tracer wires
Used with standard cable and pipe locators for the location of
non-metallic pipes and un-energised cables. Wavelay is laid
halfway between the pipe or cable and the surface of the
trench during backfilling.
Used with standard cable and pipe locators for the
location of non-metallic pipes and un-energised cables.
Laid halfway between the pipe or cable and the surface of Coloured tape with Wires in constant contact with earth
printed message
the trench during backfilling.
Detectaccessories
To ensure a continuous signal along the mesh it is important to use our wire crimps
and crimping tool. This gives the join sufficient strength to cope with most back
fills. If it is not installed correctly then the signal may not pass from join to join.
Technical Specifications
PRODUCT QUANTITY PER PACK PART NO.
Crimping Tool 1 043385
Stainless Steel Wire Crimps 100 043347
10
Root Guard
Detectamesh ®
Detectable Mesh
Mesh manufactured to
STANDARD TEXTS
BS EN 12613:2009 TEXT/COLOUR SIZE PART NO. TEXT/COLOUR SIZE PART NO.
Bagged for storage CAUTION-WATER MAIN BELOW 200mm x 100m 016747 - (Wire) CAUTION-FIRE MAINS BELOW 200mm x 100m 017584 - (Wire)
and protection CAUTION-WATER MAIN BELOW 200mm x 100m 016761 - (Ali/foil) CAUTION-SEWERAGE PUMPING MAIN BELOW 200mm x 100m 017607 - (Wire)
Various colours available CAUTION - STORM WATER CULVERT BELOW 200mm x 100m 016846 - (Wire) CAUTION-GRAVITY SEWER BELOW 200mm x 100m 017621 - (Wire)
Crimps and crimping CAUTION-BURIED GAS PIPE 200mm x 100m 016167 - (Wire) CAUTION-PRESSURE SEWER BELOW 200mm x 100m 017645 - (Wire)
tool available CAUTION•ELECTRIC CABLE BELOW 200mm x 100m 016181 - (Wire) CAUTION-NON POTABLE WATER MAIN BELOW 200mm x 100m 017683 - (Wire)
CAUTION-FIBRE OPTIC CABLES 200mm x 100m 017263 - (Wire) CAUTION-FUEL PIPE BELOW 200mm x 100m 017669 - (Wire)
Bespoke texts
manufactured to order RAW WATER MAIN BELOW 200mm x 100m 045969 - (Wire) CAUTION-TELEPHONE CABLE BELOW 200mm x 100m 017126 - (Wire)
Caution: Sewer Below 200mm x 100m 017508 - (Wire) CAUTION-STREET LIGHTING CABLE BELOW 200mm x 100m 016082 - (Wire)
Sizes 100mm-500mm
(subject to MOQ’s) • Special manufacture available any colour, size or language
Detectaccessories
To ensure a continuous signal along the mesh it is important to use our wire crimps
and crimping tool. This gives the join sufficient strength to cope with most back
fills. If it is not installed correctly then the signal may not pass from join to join.
Technical Specifications
PRODUCT QUANTITY PER PACK PART NO.
Crimping Tool 1 043385
Stainless Steel Wire Crimps 100 043347
11
Root Guard
Ultra-strong ®
Detectable Tape
Aluminium Foil
Detectable Marker Tape
A printed coloured plastic strip of detectable aluminium
foil tape, permanently bonded between two layers of rot
resistant plastic to prevent corrosion and increase its
tensile strength.
Available in many colours.
All 50mm tapes are boxed in dispenser cartons.
Easily located by direct connection
Continuous metallic tracer element
Detectaccessories
To ensure a continuous signal along the mesh it is important to use our ultra crimps and
crimping tool. This gives the join sufficient strength to cope with most back fills. If it is not
installed correctly then the signal may not pass from join to join.
Technical Specifications
PRODUCT QUANTITY PER PACK PART NO.
Crimping Tool 1 043385
Ultra Crimps 5 043361
12
Root Guard
Heavy duty, yet lightweight recycled polyethylene High impact resistance, manufactured
cable covers, incorporating a coloured printed to BS 2484
polyethylene warning tape laminated to the top
surface. Our environmentally friendly cable covers Rot resistant
should be laid over high voltage power cables or
other buried services which require additional Lightweight, meaning low transportation and
protection. installation costs
Available from 6mm to 18mm thick
Special manufacture available
Technical Specifications
PRODUCT TEXT/COLOUR SIZE MATERIAL PART NO.
Water, Gas and Fibre Optic cable covers can be manufactured to order
13
Root Guard
TapeTile™
Protection Warning Mesh
Our cable and pipe TapeTile™, offers far greater More protection than a standard warning tape
protection than ordinary warning tape. TapeTile™ is very
Reduced installation time
economically priced and installation time is greatly re-
duced as it is easy to transport and simple to unroll. Var- Manufactured in accordance with ENATS 12-23
Issue : 2004
ious thicknesses are available with colours and texts to
your requirements. Various thicknesses available from 1mm
upwards
Heavy duty recycled low density polyethylene sheet
with a warning tape laminated on oneside, printed Tensile strength - >10N/mm2
in black. Elongation at Break - >300%
Technical Specifications
TEXT/COLOURS SIZE PART NO.
200mm x 2.5mm x 40m 018444
150mm x 2.5mm x 40m 018420
14
Root Guard
Maxigrid™
Utility Protection Mesh
Technical Specifications
PRODUCT & COLOUR SIZE COLOUR PART NO.
15
Luran-S Snap fit Signs
Utility Marker Plates
16
Identification Signs
ID Signage Plates
17
Aluminium Marker Posts
ID Signage
Screw Earth
anchor anchor
18
TECHNICAL SUPPORT
A full range of product data sheets, case studies and project
information request forms are available from Terram technical
support or as downloads from the Terram website. www.terram.com.
DISCLAIMER
The information contained herein is, to the best of our made and no responsibility or liability is or will be accepted
knowledge, accurate in all material respects. However, since by us, any of our affiliates or our or their respective directors,
the circumstances and conditions in which such information officers, employees or agents in relation to the accuracy or
and the products mentioned herein can be used may vary completeness or use of the information contained herein or
and are beyond our control, no representation or warranty, any such products and any such liability is expressly disclaimed.
express or implied, of any nature whatsoever is or will be