Professional Documents
Culture Documents
GENERAL NOTES:
ABBREVIATIONS:
LEGEND:
CRUZ RESIDENCE
PROPOSED TWO-STOREY HOUSE
TAPULAO, ORANI, BATAAN
DRAWN CHECK
REV. DESCRIPTION DATE
BY BY
CONSULTANT:
CLIENT:
MINA S. CRUZ
PROJECT TITLE:
PROPOSED
TWO-STOREY HOUSE
TAPULAO, ORANI. BATAAN
DRAWING TITLE:
TWO-STOREY HOUSE
COVER PAGE
Initials Signed by: Date:
Drawn by: RB 19-03-21
Checked by: -
Approved by: - SHEET SIZE A3
Scale: AS SHOWN
00
KEY PLAN:
LEGEND:
EC - EXISTING COLUMN
ETB
ES
- EXISTING TIE BEAM
- EXISTING SLAB A B C D
EB - EXITING BEAM @ 1ST FLOOR
TB - NEW TIE BEAM
F1,F2,F3 - NEW FOOTING 1, 2, 3 GENERAL NOTES:
WF - NEW WALL FOOTING 1. Do not scale this drawing, use figured dimensions only.
2. This drawing has been prepared based upon survey and information supplied by others. All
1460 3825 3840
C1 - NEW COLUMN dimensions and levels are to be checked on site by contractors and inconsistencies reported
immediately to the Designer and Client prior to works being undertaken.
3. Contractors are to ensure that all works under their responsibility or the responsibility of their
1C1 - NEW COLUMN 1ST FLOOR sub-contractors are constructed and / or manufactured to comply with all relevant national and / or
local authority statutory requirements and in accordance with local building control and codes of
practice.
NC1 - COLUMN FIRST FLOOR TO MATCH EXITING 4. This drawing is to be read in conjunction with other relevant drawings, specifications, schedules
and so forth,relating to the project or projects from which this drawing has been prepared.
5. This drawing is also to be read in conjunction with drawings, specification, schedules and so forth
PC/PC1 - PLANTED COLUMN TO MATCH EXISTING F2
prepared by others and which are relevant to the project or project identified on this drawing.
6. This drawing is representative of design intent only, Contractor to supply for approval by the
Designer and Client, shop drawings and setting out rods to fully illustrate methods of construction
1
C1 PC2 of all millworks, casegoods, joinery works and other specialist finishes and features.
7. The dimensional accuracy of this drawing as it relates to site conditions is not guaranteed. The
TB ETB ETB contractor must verify all site dimensions prior to producing shop and setting out drawings.
EC EC
FOOTING SCHEDULE 8. Refer to specification documents for all finish descriptions.
9. See detailed design per item; Verify actual measurement on site before installation, based on
approved materials and detailed specifications.
DIMENSIONS (MM) S2
Copyright is reserved by them and this drawing is issued on condition that is not copied or disclosed
1750
WF by or to any anauthorized persons without the prior consent in writing of the Client.
ETB
ETB
REINFORCEMENT TB ES S2
This drawing is not to be scaled for the purposes of setting-out.
Dimension to be checked on site and verified prior to commencing the works.
ETB
WF - 400 200
2830
1 W/ 10MM LATERAL TIES @
ETB
ES
0.3M O.C.
F1
BEAM SCHEDULE
REINFORCEMENT
EC
C2
ETB
2-16MMØ 3-16MMØ 3 @100MM S2
ES
3815
BOTTOMBAR BOTTOMBAR REST @ 200MM
ETB
2-16MMØ 2-16MMØ 10MMØ STIRRUPS TB
TOPBAR TOPBAR 1@50MM;
RB 150 300 2-16MMØ 2-16MMØ 3 @100MM
BOTTOMBAR BOTTOMBAR REST @ 200MM
F1
COLUMN SCHEDULE
REINFORCEMENT C2
EC
EC
NAME WIDTH DEPTH @SUPPORT STIRRUPS 4 TB
EC EC
DRAWING STATUS
10MMØ STIRRUPS
C1 200 300 4-16MMØ 2@150MM;
REST @ 250MM
ES
ETB
TB ES
2695
10MMØ STIRRUPS
ETB
S2
C2 / 1C2 200 400 6-16MMØ 2@150MM; 00 ISSUED FOR APPROVAL 19-03-21 RB -
REST @ 250MM DRAWN CHECK
REV. DESCRIPTION DATE
BY BY
F1
CONSULTANT:
10MMØ STIRRUPS
C2
C3 150 300 4-16MMØ 2@150MM;
REST @ 250MM
5 EC
ETB
EC
C3
ETB
EC
ETB
EC
CLIENT:
SLAB WF
REINFORCEMENT S2
F3 MINA S. CRUZ
NAME TYPE THICKNESS SHORT DIRECTION LONG DIRECTION
2705
WF
TB S2
PROJECT TITLE:
F3
MATCH
S1 1 WAY 10MMØ TB @300MM 10MMØ TB @300MM
F2
PROPOSED
EXISITNG SPACING SPACING WF C3
C1
TWO-STOREY HOUSE
10MMØ BB @300MM TAPULAO, ORANI. BATAAN
10MMØ BB @300MM
SPACING SPACING
6 DRAWING TITLE:
TWO-STOREY HOUSE
S2 1 WAY SLAB @ 10MMØ TB @600MM
SPACING FOUNDATION PLAN
GROUND
Initials Signed by: Date:
Drawn by: RB 19-03-21
Checked by: -
1 FOUNDATION PLAN Approved by:
Scale:
-
AS SHOWN
SHEET SIZE A3
DWG-AR-01 SCALE
DWG-AR-01 00
KEY PLAN:
LEGEND:
EC - EXISTING COLUMN
ETB
ES
- EXISTING TIE BEAM
- EXISTING SLAB A B C D
EB - EXITING BEAM @ 1ST FLOOR
TB - NEW TIE BEAM
F1,F2,F3 - NEW FOOTING 1, 2, 3 GENERAL NOTES:
WF - NEW WALL FOOTING 1. Do not scale this drawing, use figured dimensions only.
2. This drawing has been prepared based upon survey and information supplied by others. All
1460 3825 3840
C1 - NEW COLUMN dimensions and levels are to be checked on site by contractors and inconsistencies reported
immediately to the Designer and Client prior to works being undertaken.
3. Contractors are to ensure that all works under their responsibility or the responsibility of their
1C1 - NEW COLUMN 1ST FLOOR sub-contractors are constructed and / or manufactured to comply with all relevant national and / or
local authority statutory requirements and in accordance with local building control and codes of
practice.
NC1 - COLUMN FIRST FLOOR TO MATCH EXITING 4. This drawing is to be read in conjunction with other relevant drawings, specifications, schedules
and so forth,relating to the project or projects from which this drawing has been prepared.
5. This drawing is also to be read in conjunction with drawings, specification, schedules and so forth
PC/PC1 - PLANTED COLUMN TO MATCH EXISTING prepared by others and which are relevant to the project or project identified on this drawing.
6. This drawing is representative of design intent only, Contractor to supply for approval by the
Designer and Client, shop drawings and setting out rods to fully illustrate methods of construction
1
C1 P2 of all millworks, casegoods, joinery works and other specialist finishes and features.
7. The dimensional accuracy of this drawing as it relates to site conditions is not guaranteed. The
RB ERB ERB contractor must verify all site dimensions prior to producing shop and setting out drawings.
EC EC
FOOTING SCHEDULE 8. Refer to specification documents for all finish descriptions.
9. See detailed design per item; Verify actual measurement on site before installation, based on
approved materials and detailed specifications.
DIMENSIONS (MM) RB ERB ERB Copyright is reserved by them and this drawing is issued on condition that is not copied or disclosed
1750
by or to any anauthorized persons without the prior consent in writing of the Client.
MARK DEPTH (M) REINFORCEMENT This drawing is not to be scaled for the purposes of setting-out.
Dimension to be checked on site and verified prior to commencing the works.
2830
1 W/ 10MM LATERAL TIES @ RB
BELOW ERB OPEN
BELOW
0.3M O.C.
BEAM SCHEDULE
REINFORCEMENT
EC
1C2
3815
BOTTOMBAR BOTTOMBAR REST @ 200MM 1B1 STAIRS ES
EB1
2-16MMØ 2-16MMØ 10MMØ STIRRUPS
TOPBAR TOPBAR 1@50MM;
RB 150 300 2-16MMØ 2-16MMØ 3 @100MM
BOTTOMBAR BOTTOMBAR REST @ 200MM
COLUMN SCHEDULE
REINFORCEMENT
NC1
1C2
DRAWING STATUS
10MMØ STIRRUPS
C1 200 300 4-16MMØ 2@150MM;
REST @ 250MM 2695
CONSULTANT:
10MMØ STIRRUPS
2@150MM; 1C2
C3 150 300 4-16MMØ
REST @ 250MM
5 1B1 EB1
NC1
C3
EB1
NC1
EB1
NC1
CLIENT:
SLAB
REINFORCEMENT MINA S. CRUZ
RB
RB
NAME TYPE THICKNESS SHORT DIRECTION LONG DIRECTION
2705
PROJECT TITLE:
MATCH
S1 1 WAY 10MMØ TB @300MM 10MMØ TB @300MM
PROPOSED
EXISITNG SPACING SPACING C3
C1
TWO-STOREY HOUSE
10MMØ BB @300MM TAPULAO, ORANI. BATAAN
10MMØ BB @300MM
SPACING SPACING
6 DRAWING TITLE:
TWO-STOREY HOUSE
S2 1 WAY SLAB @ 10MMØ TB @600MM
SPACING SECOND FLOOR FRAMING PLAN
GROUND
Initials Signed by: Date:
Drawn by: RB 19-03-21
Checked by: -
1 SECOND FLOOR FRAMING PLAN Approved by:
Scale:
-
AS SHOWN
SHEET SIZE A3
DWG-AR-02 SCALE
DWG-AR-02 00
KEY PLAN:
LEGEND:
EC - EXISTING COLUMN
ETB
ES
- EXISTING TIE BEAM
- EXISTING SLAB A B C D
EB - EXITING BEAM @ 1ST FLOOR
TB - NEW TIE BEAM
F1,F2,F3 - NEW FOOTING 1, 2, 3 GENERAL NOTES:
WF - NEW WALL FOOTING 1. Do not scale this drawing, use figured dimensions only.
2. This drawing has been prepared based upon survey and information supplied by others. All
C1 - NEW COLUMN dimensions and levels are to be checked on site by contractors and inconsistencies reported
immediately to the Designer and Client prior to works being undertaken.
3. Contractors are to ensure that all works under their responsibility or the responsibility of their
1C1 - NEW COLUMN 1ST FLOOR sub-contractors are constructed and / or manufactured to comply with all relevant national and / or
local authority statutory requirements and in accordance with local building control and codes of
1460 3825 3840 practice.
NC1 - COLUMN FIRST FLOOR TO MATCH EXITING 4. This drawing is to be read in conjunction with other relevant drawings, specifications, schedules
and so forth,relating to the project or projects from which this drawing has been prepared.
5. This drawing is also to be read in conjunction with drawings, specification, schedules and so forth
PC/PC1 - PLANTED COLUMN TO MATCH EXISTING prepared by others and which are relevant to the project or project identified on this drawing.
6. This drawing is representative of design intent only, Contractor to supply for approval by the
Designer and Client, shop drawings and setting out rods to fully illustrate methods of construction
1
of all millworks, casegoods, joinery works and other specialist finishes and features.
7. The dimensional accuracy of this drawing as it relates to site conditions is not guaranteed. The
contractor must verify all site dimensions prior to producing shop and setting out drawings.
DIMENSIONS (MM) Copyright is reserved by them and this drawing is issued on condition that is not copied or disclosed
1750
by or to any anauthorized persons without the prior consent in writing of the Client.
MARK DEPTH (M) REINFORCEMENT This drawing is not to be scaled for the purposes of setting-out.
Dimension to be checked on site and verified prior to commencing the works.
2830
1 W/ 10MM LATERAL TIES @
0.3M O.C.
BEAM SCHEDULE
REINFORCEMENT 1C1
3815
BOTTOMBAR BOTTOMBAR REST @ 200MM
2-16MMØ 2-16MMØ 10MMØ STIRRUPS RB
TOPBAR TOPBAR 1@50MM;
RB 150 300 2-16MMØ 2-16MMØ 3 @100MM
BOTTOMBAR BOTTOMBAR REST @ 200MM
COLUMN SCHEDULE
REINFORCEMENT
NC1
1C2
DRAWING STATUS
10MMØ STIRRUPS
C1 200 300 4-16MMØ 2@150MM;
REST @ 250MM 2695
10MMØ STIRRUPS RB
2@150MM; RB
C2 / 1C2 200 400 6-16MMØ 00 ISSUED FOR APPROVAL 19-03-21 RB -
REST @ 250MM DRAWN CHECK
REV. DESCRIPTION DATE
BY BY
CONSULTANT:
10MMØ STIRRUPS
2@150MM; 1C3
C3 150 300 4-16MMØ
REST @ 250MM
5 RB
NC1
RB
NC1
RB
NC1
CLIENT:
SLAB
REINFORCEMENT MINA S. CRUZ
NAME TYPE THICKNESS SHORT DIRECTION LONG DIRECTION
2705
PROJECT TITLE:
MATCH
S1 1 WAY 10MMØ TB @300MM 10MMØ TB @300MM
PROPOSED
EXISITNG SPACING SPACING
TWO-STOREY HOUSE
10MMØ BB @300MM TAPULAO, ORANI. BATAAN
10MMØ BB @300MM
SPACING SPACING
6 DRAWING TITLE:
TWO-STOREY HOUSE
S2 1 WAY SLAB @ 10MMØ TB @600MM
SPACING ROOF FRAMING PLAN
GROUND
Initials Signed by: Date:
Drawn by: RB 19-03-21
Checked by: -
1 ROOF FRAMING PLAN Approved by:
Scale:
-
AS SHOWN
SHEET SIZE A3
DWG-AR-03 SCALE
DWG-AR-03 00
KEY PLAN:
A B C D A B C D
GENERAL NOTES:
1 1
of all millworks, casegoods, joinery works and other specialist finishes and features.
7. The dimensional accuracy of this drawing as it relates to site conditions is not guaranteed. The
contractor must verify all site dimensions prior to producing shop and setting out drawings.
8. Refer to specification documents for all finish descriptions.
9. See detailed design per item; Verify actual measurement on site before installation, based on
approved materials and detailed specifications.
1750
by or to any anauthorized persons without the prior consent in writing of the Client.
This drawing is not to be scaled for the purposes of setting-out.
Dimension to be checked on site and verified prior to commencing the works.
ABBREVIATIONS:
LEGEND:
BEDROOM 1 BEDROOM 1
2830
2830
LIVING LIVING
3 3
T&B T&B
DINING DINING
3815
3815
T&B T&B
UP UP
4 4 DRAWING STATUS
KITCHEN KITCHEN
BEDROOM 3 BEDROOM 2 BEDROOM 3 BEDROOM 2
2695
2695
00 ISSUED FOR APPROVAL 19-03-21 RB -
DRAWN CHECK
REV. DESCRIPTION DATE
BY BY
CONSULTANT:
5 5
CLIENT:
MINA S. CRUZ
2705
2705
PROJECT TITLE:
PROPOSED
TWO-STOREY HOUSE
TAPULAO, ORANI. BATAAN
6 6 DRAWING TITLE:
TWO-STOREY HOUSE
EXISTING WALL PARTITION PLAN
& DEMOLITION PLAN
Initials Signed by: Date:
Drawn by: RB 19-03-21
Checked by: -
1 EXISTING WALL PARTITION PLAN 2 DEMOLITION PLAN Approved by:
Scale:
-
AS SHOWN
SHEET SIZE A3
A B C D A B C D
A A
DWG-AR-09a DWG-AR-09a GENERAL NOTES:
1 1
4 W4 W2 of all millworks, casegoods, joinery works and other specialist finishes and features.
7. The dimensional accuracy of this drawing as it relates to site conditions is not guaranteed. The
contractor must verify all site dimensions prior to producing shop and setting out drawings.
455
8. Refer to specification documents for all finish descriptions.
285 600 700 900 1200 1340 9. See detailed design per item; Verify actual measurement on site before installation, based on
490
approved materials and detailed specifications.
1000
1610
1750
1750
1595
STUDY
600
by or to any anauthorized persons without the prior consent in writing of the Client.
BALCONY D1 ENTRANCE W4 This drawing is not to be scaled for the purposes of setting-out.
Dimension to be checked on site and verified prior to commencing the works.
HT 2150
1600 3440
ABBREVIATIONS:
505
1200 400 1200 2240
305
2 2
W1 W1 W1
F.F.L = FINISH FLOOR LEVEL
340
F.C.L = FINISH CEILING LEVEL
1470 600 100 600 100 600 300 1200 550 1200 2240
S.C.L = SCREED LEVEL
UP
300
DINING
2830
2830
1
LIVING W1
2
3630
3
W1
4
860
340
3 3
W2 W2
6
75
AC 1350 1200 1300 1370 1200 1120
7
OPENING
3850 3690
800
650
425mm HT
8 2100mm
2970
3480
TOP HT
1500
75
9
300
DRESSING AREA
2375
2350
450
10
2450
2820
KITCHEN
D 11
B D B
1700
1100
1400
500
12
TOILET & BATH W5
3815
3815
DWG-AR-09b DWG-AR-09a DWG-AR-09b DWG-AR-09a
3660
4720 HT 2100 2700
13 BEDROOM 4
450
2545 2175 D3 2170 150 600 1950
300
14
355
330
15 200 600 620 1400 1950
1420 D3
4990
1310
16
1160
1160
1160
HT 2100
500
500
1060
STORAGE/TREADMILL TOILET W5 865 900 515 455 355 1200 710 TOILET & BATH W5
17 4375 HT 2100
AC OPENING
D2
330
330
18 1740 1080 2005 900 250 900 320 D3 345mm HT
2550
4 4 DN
HT 2150 2100mm TOP HT
165
1585 1955 570 600 800 900 1015 900 W2
D2 D2 DRAWING STATUS
2815
965
HT 2150 HT 2150 D2
900
1750
1600
HT 2150
2700
2550
2550
2550
2550
2695
2695
600
1485
REV. DESCRIPTION DATE
BY BY
1185 1000 620
900
900
965
D2 CONSULTANT:
AC OPENING 2820
HT 2150 D2 345mm HT 2735 5775
930 1000 890
5 5
HT 2150 2100mm TOP HT
50
50
260
W3 CLIENT:
AC OPENING
1295
1295
10 345mm HT UP UP
00
16
2600mm TOP HT
MINA S. CRUZ
50
58 LAUNDRY AREA
2705
2705
5
BEDROOM 3 1035
PROJECT TITLE:
1230
1080
PROPOSED
1165
1115
2640
2650
TWO-STOREY HOUSE
TAPULAO, ORANI. BATAAN
6 C
6 C
DRAWING TITLE:
TWO-STOREY HOUSE
DWG-AR-09b DWG-AR-09b
PROPOSED WALL PARTITION
PLAN
Initials Signed by: Date:
Drawn by: RB 19-03-21
Checked by: -
1 PROPOSED WALL PARTITION PLAN - GROUND FLOOR 2 PROPOSED WALL PARTITION PLAN - SECOND FLOOR Approved by:
Scale:
-
AS SHOWN
SHEET SIZE A3
A B C D
GENERAL NOTES:
OVERHANG
4. This drawing is to be read in conjunction with other relevant drawings, specifications, schedules
and so forth,relating to the project or projects from which this drawing has been prepared.
1000
5. This drawing is also to be read in conjunction with drawings, specification, schedules and so forth
prepared by others and which are relevant to the project or project identified on this drawing.
6. This drawing is representative of design intent only, Contractor to supply for approval by the
Designer and Client, shop drawings and setting out rods to fully illustrate methods of construction
1
of all millworks, casegoods, joinery works and other specialist finishes and features.
7. The dimensional accuracy of this drawing as it relates to site conditions is not guaranteed. The
contractor must verify all site dimensions prior to producing shop and setting out drawings.
8. Refer to specification documents for all finish descriptions.
1000 9. See detailed design per item; Verify actual measurement on site before installation, based on
approved materials and detailed specifications.
OVERHANG
5° (DEGREE) SLOPE This drawing is the property of the Client.
Copyright is reserved by them and this drawing is issued on condition that is not copied or disclosed
1755
by or to any anauthorized persons without the prior consent in writing of the Client.
230 This drawing is not to be scaled for the purposes of setting-out.
Dimension to be checked on site and verified prior to commencing the works.
ABBREVIATIONS:
LEGEND:
2830
OVERHANG
1000
3
3815
5° (DEGREE) SLOPE
230
4 DRAWING STATUS
2695
DRAWN CHECK
REV. DESCRIPTION DATE
BY BY
CONSULTANT:
1000
5 OVERHANG
OVERHANG
1000
CLIENT:
MINA S. CRUZ
2705
PROJECT TITLE:
PROPOSED
230 5° (DEGREE) SLOPE
TWO-STOREY HOUSE
TAPULAO, ORANI. BATAAN
230
6 DRAWING TITLE:
TWO-STOREY HOUSE
DWG-AR-06 SCALE
DWG-AR-06 00
KEY PLAN:
A B C D A B C D
GENERAL NOTES:
1 1
of all millworks, casegoods, joinery works and other specialist finishes and features.
7. The dimensional accuracy of this drawing as it relates to site conditions is not guaranteed. The
contractor must verify all site dimensions prior to producing shop and setting out drawings.
8. Refer to specification documents for all finish descriptions.
9. See detailed design per item; Verify actual measurement on site before installation, based on
approved materials and detailed specifications.
1750
1755
BALCONY ENTRANCE A
STUDY by or to any anauthorized persons without the prior consent in writing of the Client.
This drawing is not to be scaled for the purposes of setting-out.
Dimension to be checked on site and verified prior to commencing the works.
880
ABBREVIATIONS:
155
2830
LIVING SINGLE POLE POWER OUTLET (WALL
MOUNTED) @ 2600mm AFFL ABOVE FCL
2 FOR WATER HEATER
UP
DOUBLE POLE POWER OUTLET (WALL
A MOUNTED) @ 450mm AFFL
3 04
250 250
AC
OPENING
3 B
DOUBLE POLE POWER OUTLET (WALL
MOUNTED) @ 1100mm AFFL
250
07 TOILET & BATH
250
SINGLE POLE POWER OUTLET W/
COVER (WALL MOUNTED) @ 2100mm
3815
3815
AFFL
B 350
BEDROOM 4 DOUBLE POLE POWER OUTLET W/
600
1130
STORAGE/TREADMILL 250 TOILET TOILET & BATH 375
13 AC OPENING
345mm HT
15 CABLE OUTLET (WALL MOUNTED) @
450mm AFFL
4 05
A
A A 4 06 DN
2100mm TOP HT
AC1 2
DRAWING STATUS
250 235 235
200
2695
2695
BEDROOM 2 BEDROOM 1 BALCONY
00 ISSUED FOR APPROVAL 19-03-21 RB -
11
12 REV. DESCRIPTION DATE
DRAWN CHECK
BY BY
CONSULTANT:
AC OPENING
AC1
345mm HT
5 5
200
2100mm TOP HT
2
AC CLIENT:
A AC OPENING
345mm HT UP UP
2600mm TOP HT
MINA S. CRUZ
LAUNDRY AREA
2705
2705
250
PROPOSED
TWO-STOREY HOUSE
TAPULAO, ORANI. BATAAN
6 6 DRAWING TITLE:
TWO-STOREY HOUSE
A B C D A B C D
GENERAL NOTES:
1 1
of all millworks, casegoods, joinery works and other specialist finishes and features.
7. The dimensional accuracy of this drawing as it relates to site conditions is not guaranteed. The
contractor must verify all site dimensions prior to producing shop and setting out drawings.
8. Refer to specification documents for all finish descriptions.
9. See detailed design per item; Verify actual measurement on site before installation, based on
approved materials and detailed specifications.
S1 ABBREVIATIONS:
S
S
2 2
S
S2 S2
F.F.L = FINISH FLOOR LEVEL
SA F.C.L = FINISH CEILING LEVEL
LEGEND:
SURFACE-MOUNTED
LT-01
DOWNLIGHT
UP
LT-03 PENDANT LIGHT
3 3
S1 @ 1350mm AFFL
S 2-GANG LIGHT SWITCH
S
S2 @ 1350mm AFFL
S3
LT-03 LT-03 LT-03 S 3-GANG LIGHT SWITCH
S3 @ 1350mm AFFL
TO LIGHT ON S 3-WAY 1-GANG LIGHT
2ND FLR SA SWITCH @ 1350mm AFFL
LT-01
LT-01
LT-02 LT-02
LT-01
01 LT-02
LT-01
S
S1 S2
S
LT-01 LT-01 LT-01 S LT-02
S
4 02
S2
S1 S2 4 DN
SA S1
S1
LT-03
S S 03 SS DRAWING STATUS
LT-02
S
LT-01 LT-01 LT-01 S2 00 ISSUED FOR APPROVAL 19-03-21 RB -
S2 S
5 S1 5
S CLIENT:
UP UP
MINA S. CRUZ
6 6 DRAWING TITLE:
TWO-STOREY HOUSE
NUMBER OF OUTLETS
CKT. VOLTAGE WATTS
C. W. POLE WIRE Conduti AMPERE
NO. LIGHT OUTLET ACU REF RANGE RATING RATING AT AF
HEATER OTHERS SIZE Size
01 13 220V 1300 2 3.5 20mmØ PVC 20 100 5.9
02 10 220V 1000 2 3.5 20mmØ PVC 20 100 4.5
03 07 220V 700 2 3.5 20mmØ PVC 20 100 3.2 GENERAL NOTES:
04 05 X 2 220V 1800 2 3.5 20mmØ PVC 20 100 3.2 1. Do not scale this drawing, use figured dimensions only.
2. This drawing has been prepared based upon survey and information supplied by others. All
05 05 X 2 220V 1800 2 3.5 20mmØ PVC 20 100 8.2 dimensions and levels are to be checked on site by contractors and inconsistencies reported
immediately to the Designer and Client prior to works being undertaken.
3. Contractors are to ensure that all works under their responsibility or the responsibility of their
06 03 X 2 220V 1080 2 3.5 20mmØ PVC 20 100 8.2 sub-contractors are constructed and / or manufactured to comply with all relevant national and / or
local authority statutory requirements and in accordance with local building control and codes of
practice.
07 01 01 220V 4000 2 8 20mmØ PVC 40 100 18.8 4. This drawing is to be read in conjunction with other relevant drawings, specifications, schedules
and so forth,relating to the project or projects from which this drawing has been prepared.
5. This drawing is also to be read in conjunction with drawings, specification, schedules and so forth
08 01 220V 2000 2 5.5 20mmØ PVC 30 100 9.1 prepared by others and which are relevant to the project or project identified on this drawing.
6. This drawing is representative of design intent only, Contractor to supply for approval by the
Designer and Client, shop drawings and setting out rods to fully illustrate methods of construction
09 01 220V 4000 2 8 25mmØ PVC 40 100 18.8 of all millworks, casegoods, joinery works and other specialist finishes and features.
7. The dimensional accuracy of this drawing as it relates to site conditions is not guaranteed. The
10 01 220V 2000 2 3.5 20mmØ PVC 30 100 9.1 contractor must verify all site dimensions prior to producing shop and setting out drawings.
8. Refer to specification documents for all finish descriptions.
9. See detailed design per item; Verify actual measurement on site before installation, based on
11 01 220V 1500 2 3.5 20mmØ PVC 20 100 6.8 approved materials and detailed specifications.
1 LOAD SCHEDULE
DWG-AR-07c SCALE
Main
20A 150A
GF L.O. 01 POWER SUPPLY
20A 20A
FF L.O. 03 02 GF L.O.
20A 20A
GF C.O. 05 04 GF C.O.
40A 20A
RANGE & HOOD 07 06 FF C.O. DRAWING STATUS
40A 30A
KITCHEN SP.O. 09 08 REFRIGERATOR 00 ISSUED FOR APPROVAL 19-03-21 RB -
DRAWN CHECK
REV. DESCRIPTION DATE
BY BY
30A 20A
10 11
CONSULTANT:
AC - SALA GF ROOM AC
20A 30A
GF ROOM AC 12 13 FF A.C. CLIENT:
MINA S. CRUZ
40A 40A
GF WATER HEATER 14 15 GF WATER HEATER PROJECT TITLE:
PROPOSED
TWO-STOREY HOUSE
TAPULAO, ORANI. BATAAN
DRAWING TITLE:
TWO-STOREY HOUSE
DWG-AR-07c 00
KEY PLAN:
A B C D A B C D
GENERAL NOTES:
1 1
of all millworks, casegoods, joinery works and other specialist finishes and features.
7. The dimensional accuracy of this drawing as it relates to site conditions is not guaranteed. The
contractor must verify all site dimensions prior to producing shop and setting out drawings.
8. Refer to specification documents for all finish descriptions.
9. See detailed design per item; Verify actual measurement on site before installation, based on
approved materials and detailed specifications.
1750
BALCONY ENTRANCE STUDY by or to any anauthorized persons without the prior consent in writing of the Client.
This drawing is not to be scaled for the purposes of setting-out.
Dimension to be checked on site and verified prior to commencing the works.
ABBREVIATIONS:
LEGEND:
DINING
2830
2830
LIVING
UP
3 3
3815
BEDROOM 4
@600 FFL
D.O.
1/2" POTABLE PVC CWL 1/2" POTABLE PVC CWL 1/2" POTABLE PVC CWL
VALVE
VALVE
FD
D.O.
@350 FLL @200 FLL
@600 FFL
A VALVE
S.O.
A VALVE
S.O.
FD
STORAGE/TREADMILL TOILET TOILET & BATH
150
4 4
@350 FLL @200 FLL
@600 FFL S.O. S.O. @900mm FFL
D.O. A VALVE A VALVE SHOWER MIXER
VALVE
DN
2695
BEDROOM 2 BEDROOM 1 BALCONY
4"
3
00 ISSUED FOR APPROVAL 19-03-21 RB -
DRAWN CHECK
4"
BY BY
CONSULTANT:
5 5
3/4" POTABLE PVC CWL
CLIENT:
UP UP
MINA S. CRUZ
LAUNDRY AREA
2705
2705
PROPOSED
@1200 FFL
D.O.
VALVE
TWO-STOREY HOUSE
TAPULAO, ORANI. BATAAN
6 6 DRAWING TITLE:
TWO-STOREY HOUSE
A B C D A B C D
BARANGAY
DRAINAGE
4" WP TO 4" WP
4" CO
GENERAL NOTES:
WP
3. Contractors are to ensure that all works under their responsibility or the responsibility of their
UP ROOFING LINE sub-contractors are constructed and / or manufactured to comply with all relevant national and / or
4"
local authority statutory requirements and in accordance with local building control and codes of
practice.
4. This drawing is to be read in conjunction with other relevant drawings, specifications, schedules
and so forth,relating to the project or projects from which this drawing has been prepared.
5. This drawing is also to be read in conjunction with drawings, specification, schedules and so forth
prepared by others and which are relevant to the project or project identified on this drawing.
6. This drawing is representative of design intent only, Contractor to supply for approval by the
Designer and Client, shop drawings and setting out rods to fully illustrate methods of construction
1 1
of all millworks, casegoods, joinery works and other specialist finishes and features.
7. The dimensional accuracy of this drawing as it relates to site conditions is not guaranteed. The
4" CO contractor must verify all site dimensions prior to producing shop and setting out drawings.
8. Refer to specification documents for all finish descriptions.
9. See detailed design per item; Verify actual measurement on site before installation, based on
approved materials and detailed specifications.
4" WP
This drawing is the property of the Client.
Copyright is reserved by them and this drawing is issued on condition that is not copied or disclosed
1755
1750
BALCONY ENTRANCE STUDY by or to any anauthorized persons without the prior consent in writing of the Client.
This drawing is not to be scaled for the purposes of setting-out.
Dimension to be checked on site and verified prior to commencing the works.
ABBREVIATIONS:
2 2
4" WP
F.F.L = FINISH FLOOR LEVEL
F.C.L = FINISH CEILING LEVEL
S.C.L = SCREED LEVEL
LEGEND:
DINING
2830
2830
LIVING
UP
4" WP
3 4" SP TO SEPTIC TANK
3
4" CO
4" SP TO SEPTIC TANK DRESSING AREA
2" DP 590
KITCHEN
FDFD OPENING FD
3815
725
BEDROOM 4
4" WP
3" WP 3" WP
FCO
FD FD
2" DP 2" DP
OPENING OPENING 4" SP 3" VENT UP 550
3" VENT UP
TO ROOF
FD
TOILET
STORAGE/TREADMILL
@5000mm FFL @500mm FFL 300
TOILET & BATH TO ROOF
& 4" SOIL
600
& 4" SOIL
300
4 PIPE DOWN
4" CO TO SEPTIC
TANK
4 DN
4" CO
2" DP
PIPE DOWN
TO SEPTIC
TANK DRAWING STATUS
OPENING
4" WP
@500mm FFL
2695
2695
BEDROOM 2 BEDROOM 1 BALCONY
00 ISSUED FOR APPROVAL 19-03-21 RB -
DRAWN CHECK
REV. DESCRIPTION DATE
BY BY
CONSULTANT:
5 5
4" WP
FD
4" CO CLIENT:
UP UP
MINA S. CRUZ
LAUNDRY AREA
2705
2705
PROPOSED
TWO-STOREY HOUSE
TAPULAO, ORANI. BATAAN
6 6 DRAWING TITLE:
TWO-STOREY HOUSE
GENERAL NOTES:
LEGEND FOR WATER SUPPLY: LEGEND FOR DRAINAGE: 1. Do not scale this drawing, use figured dimensions only.
2. This drawing has been prepared based upon survey and information supplied by others. All
dimensions and levels are to be checked on site by contractors and inconsistencies reported
immediately to the Designer and Client prior to works being undertaken.
3. Contractors are to ensure that all works under their responsibility or the responsibility of their
sub-contractors are constructed and / or manufactured to comply with all relevant national and / or
local authority statutory requirements and in accordance with local building control and codes of
practice.
4. This drawing is to be read in conjunction with other relevant drawings, specifications, schedules
Right Cold Supply - supply by 21 " PVC DP - Drain Pipe (2" Sanitary PVC) 8. Refer to specification documents for all finish descriptions.
150 9. See detailed design per item; Verify actual measurement on site before installation, based on
approved materials and detailed specifications.
pipe from 800mm FFL to Ceiling FD - Floor drain (connected to 2" P trap) LEGEND:
- 3/4 " PVC Potable Supply Pipe WATERPROOF COATING REV. DESCRIPTION DATE
DRAWN CHECK
BY BY
CONSULTANT:
NOTES :
- COVER ALL OPENING OF PIPES TO PREVENT CLIENT:
MINA S. CRUZ
UNNECESSARY MATERIALS FROM ENTERING,
REMOVE COVERS ONLY AT THE TIME OF PROJECT TITLE:
TWO-STOREY HOUSE
LEGEND FOR WATER
SUPPLY & DRAINAGE
Initials Signed by: Date:
Drawn by: RB 19-03-21
Checked by: -
Approved by: - SHEET SIZE A3
Scale: AS SHOWN
DWG-AR-08c 00
KEY PLAN:
GENERAL NOTES:
ABBREVIATIONS:
LEGEND:
DRAWING STATUS
DRAWN CHECK
REV. DESCRIPTION DATE
BY BY
CONSULTANT:
CLIENT:
MINA S. CRUZ
PROJECT TITLE:
PROPOSED
TWO-STOREY HOUSE
TAPULAO, ORANI. BATAAN
DRAWING TITLE:
TWO-STOREY HOUSE
PLUMBING 3D REFERENCE -
EXTERNAL PIPING ELEVATION
Initials Signed by: Date:
Drawn by: RB 19-03-21
Checked by: -
Approved by: - SHEET SIZE A3
Scale: AS SHOWN
DWG-AR-08d 00
KEY PLAN:
GENERAL NOTES:
ABBREVIATIONS:
LEGEND:
1 EXTERIOR ELEVATION A
DWG-AR-09a SCALE
DRAWING STATUS
DRAWN CHECK
REV. DESCRIPTION DATE
BY BY
CONSULTANT:
AC OPENING 425mm
HT 2100mm TOP HT
CLIENT:
MINA S. CRUZ
PROJECT TITLE:
PROPOSED
TWO-STOREY HOUSE
TAPULAO, ORANI. BATAAN
DRAWING TITLE:
TWO-STOREY HOUSE
PROPOSED EXTERIOR
ELEVATIONS
Initials Signed by: Date:
Drawn by: RB 19-03-21
Checked by: -
2 EXTERIOR ELEVATION B Approved by:
Scale:
-
AS SHOWN
SHEET SIZE A3
DWG-AR-09a SCALE
DWG-AR-09a 00
KEY PLAN:
AC OPENING 345mm
HT 2100mm TOP HT
GENERAL NOTES:
ABBREVIATIONS:
LEGEND:
1 EXTERIOR ELEVATION C
DWG-AR-09b SCALE
DRAWING STATUS
DRAWN CHECK
REV. DESCRIPTION DATE
BY BY
CONSULTANT:
CLIENT:
MINA S. CRUZ
PROJECT TITLE:
PROPOSED
TWO-STOREY HOUSE
TAPULAO, ORANI. BATAAN
DRAWING TITLE:
TWO-STOREY HOUSE
PROPOSED EXTERIOR
ELEVATIONS
Initials Signed by: Date:
Drawn by: RB 19-03-21
Checked by: -
2 EXTERIOR ELEVATION D Approved by:
Scale:
-
AS SHOWN
SHEET SIZE A3
DWG-AR-09b SCALE
DWG-AR-09b 00
KEY PLAN:
W1 W2 W3 W4 W5 W6
400
1000
1000
1000
GENERAL NOTES:
500 1. Do not scale this drawing, use figured dimensions only.
600
2. This drawing has been prepared based upon survey and information supplied by others. All
1500
dimensions and levels are to be checked on site by contractors and inconsistencies reported
immediately to the Designer and Client prior to works being undertaken.
3. Contractors are to ensure that all works under their responsibility or the responsibility of their
sub-contractors are constructed and / or manufactured to comply with all relevant national and / or
local authority statutory requirements and in accordance with local building control and codes of
practice.
4. This drawing is to be read in conjunction with other relevant drawings, specifications, schedules
2100
2100
2100
2100
2100
and so forth,relating to the project or projects from which this drawing has been prepared.
5. This drawing is also to be read in conjunction with drawings, specification, schedules and so forth
prepared by others and which are relevant to the project or project identified on this drawing.
1200 1000 600 6. This drawing is representative of design intent only, Contractor to supply for approval by the
Designer and Client, shop drawings and setting out rods to fully illustrate methods of construction
1700
1700
of all millworks, casegoods, joinery works and other specialist finishes and features.
7. The dimensional accuracy of this drawing as it relates to site conditions is not guaranteed. The
contractor must verify all site dimensions prior to producing shop and setting out drawings.
8. Refer to specification documents for all finish descriptions.
9. See detailed design per item; Verify actual measurement on site before installation, based on
1100 approved materials and detailed specifications.
1100
1100
1100
This drawing is the property of the Client.
Copyright is reserved by them and this drawing is issued on condition that is not copied or disclosed
600 by or to any anauthorized persons without the prior consent in writing of the Client.
This drawing is not to be scaled for the purposes of setting-out.
Dimension to be checked on site and verified prior to commencing the works.
600
ABBREVIATIONS:
200
200
200
200
200
BALCONY FLOOR LEVEL
LEGEND:
QTY: 6 nos. QTY: 4 nos. QTY: 3 nos. QTY: 2 nos. QTY: 3 nos. QTY: 1 no.
TYPE: CASEMENT SWING TYPE: CASEMENT SWING TYPE: CASEMENT SWING TYPE: CASEMENT SWING TYPE: AWNING TYPE: SLIDING
FINISH: CLEAR GLASS W/ FINISH: CLEAR GLASS W/ FINISH: CLEAR GLASS W/ FINISH: CLEAR GLASS W/ FINISH: CLEAR GLASS W/ FINISH: CLEAR GLASS W/
WHITE ALUMINUM FRAME W/ WHITE ALUMINUM FRAME W/ WHITE ALUMINUM FRAME W/ WHITE ALUMINUM FRAME W/ WHITE ALUMINUM FRAME W/ WHITE ALUMINUM FRAME W/
COMPLETE GASKET AND COMPLETE GASKET AND COMPLETE GASKET AND COMPLETE GASKET AND COMPLETE GASKET AND COMPLETE GASKET AND
SEAL TO PREVENT WATER SEAL TO PREVENT WATER SEAL TO PREVENT WATER SEAL TO PREVENT WATER SEAL TO PREVENT WATER SEAL TO PREVENT WATER
INGRESS INGRESS INGRESS INGRESS INGRESS INGRESS
D1 D2 D3
900 600
1000
DRAWING STATUS
2100
DRAWN CHECK
REV. DESCRIPTION DATE
BY BY
2150
CONSULTANT:
CLIENT:
MINA S. CRUZ
PROJECT TITLE:
FINISH FLOOR LEVEL
PROPOSED
200
200
DWG-AR-10 SCALE
CONFIRMED ON SITE BEFORE PRODUCTION DWG-AR-10 00
KEY PLAN:
A B C D A B C D
GENERAL NOTES:
1 1
of all millworks, casegoods, joinery works and other specialist finishes and features.
7. The dimensional accuracy of this drawing as it relates to site conditions is not guaranteed. The
contractor must verify all site dimensions prior to producing shop and setting out drawings.
8. Refer to specification documents for all finish descriptions.
9. See detailed design per item; Verify actual measurement on site before installation, based on
BENCH approved materials and detailed specifications.
SEWING MACHINE
This drawing is the property of the Client.
Copyright is reserved by them and this drawing is issued on condition that is not copied or disclosed
1750
1750
SHOE by or to any anauthorized persons without the prior consent in writing of the Client.
BALCONY ENTRANCE CABINET STUDY This drawing is not to be scaled for the purposes of setting-out.
Dimension to be checked on site and verified prior to commencing the works.
ABBREVIATIONS:
2 2
BOOKSHELF
LEGEND:
LIVING
2830
2830
DINING
UP
CABINET
FD
3815
TOILET & BATH
BEDROOM 4 CABINET
FRIDGE
FD
STORAGE/TREADMILL CABINET
TOILET
SHELF
4 CABINET
4 DN
FD
FD
DRAWING STATUS
BEDROOM 2 BEDROOM 1
CABINET CABINET
2695
2695
BALCONY
00 ISSUED FOR APPROVAL 19-03-21 RB -
DRAWN CHECK
REV. DESCRIPTION DATE
SHELF SHELF BY BY
CONSULTANT:
SHELF CABINET
5 5
CLIENT:
BEDROOM 3 UP UP
MINA S. CRUZ
LAUNDRY AREA
2705
2705
PROJECT TITLE:
WASHING MACHINE
SHELF
PROPOSED
SHELF
TWO-STOREY HOUSE
TAPULAO, ORANI. BATAAN
6 6 DRAWING TITLE:
TWO-STOREY HOUSE
PROPOSED FURNITURE
LAYOUT
Initials Signed by: Date:
Drawn by: RB 19-03-21
Checked by: -
1 PROPOSED FURNITURE LAYOUT- GROUND FLOOR 2 PROPOSED FURNITURE LAYOUT - SECOND FLOOR Approved by:
Scale:
-
AS SHOWN
SHEET SIZE A3
A B C D A B C D
GENERAL NOTES:
1 1
of all millworks, casegoods, joinery works and other specialist finishes and features.
7. The dimensional accuracy of this drawing as it relates to site conditions is not guaranteed. The
contractor must verify all site dimensions prior to producing shop and setting out drawings.
8. Refer to specification documents for all finish descriptions.
CH 2970 9. See detailed design per item; Verify actual measurement on site before installation, based on
605
approved materials and detailed specifications.
805
795
1720 1720
1795 1830 600 980 This drawing is the property of the Client.
Copyright is reserved by them and this drawing is issued on condition that is not copied or disclosed
1750
1750
LT-02 CH 2770 by or to any anauthorized persons without the prior consent in writing of the Client.
This drawing is not to be scaled for the purposes of setting-out.
LT-02 LT-02 Dimension to be checked on site and verified prior to commencing the works.
1005
805
800
CH 2970
S1 ABBREVIATIONS:
S
S
2 2
S
S2 S2
F.F.L = FINISH FLOOR LEVEL
SA F.C.L = FINISH CEILING LEVEL
1340
LEGEND:
2830
LT-02 LT-02 LT-02 LT-02 WHITE PAINT FINISH ON
PT-02
PLYWOOD CEILING
UP SURFACE-MOUNTED
1340
CH 2770 LT-01
DOWNLIGHT
CH 2770
LT-02 WALL LIGHT
S3
LT-03 LT-03 LT-03
1050
1475
S1 @ 1350mm AFFL
1830
TO LIGHT ON 1085 1085
800
2225 1625
1410 1410 S 3-GANG LIGHT SWITCH
1200 LT-01 1200
1200
3815
CH 2400
1125
LT-01
875
S 3-WAY 1-GANG LIGHT
700
S
S1
1830
S2
S
575
580
CH 2400
530
580
S
530
530
4 S2
S1 S2 4 DN
SA S1
S1
LT-03 1410
S S SS 1410 DRAWING STATUS
975
CH 2770
1275
1275
1275
1365
S
2695
2695
1085
EQ
LT-01 LT-01 LT-01 CH 2400 S2 00 ISSUED FOR APPROVAL 19-03-21 RB -
CH 2770 DRAWN CHECK
LT-01 REV. DESCRIPTION DATE
BY BY
1275
1275
1275
CH 2770
LT-03
975
CONSULTANT:
EQ
S2 S
5 S1 5
S CLIENT:
1295
1425
UP UP
520 520 MINA S. CRUZ
1510
2705
2705
6 6 DRAWING TITLE:
TWO-STOREY HOUSE
PROPOSED REFLECTED
CEILING PLAN
Initials Signed by: Date:
Drawn by: RB 19-03-21
Checked by: -
1 PROPOSED REFLECTED CEILING PLAN- GROUND FLOOR 2 PROPOSED REFLECTED CEILING PLAN - SECOND FLOOR Approved by:
Scale:
-
AS SHOWN
SHEET SIZE A3
A B C D A B C D
GENERAL NOTES:
1 1
of all millworks, casegoods, joinery works and other specialist finishes and features.
7. The dimensional accuracy of this drawing as it relates to site conditions is not guaranteed. The
contractor must verify all site dimensions prior to producing shop and setting out drawings.
8. Refer to specification documents for all finish descriptions.
9. See detailed design per item; Verify actual measurement on site before installation, based on
approved materials and detailed specifications.
AREA: 11 sqm
This drawing is the property of the Client.
Copyright is reserved by them and this drawing is issued on condition that is not copied or disclosed
F.F.L F.F.L
1750
1750
BALCONY ENTRANCE STUDY by or to any anauthorized persons without the prior consent in writing of the Client.
This drawing is not to be scaled for the purposes of setting-out.
-0.20 m ±0.00 m Dimension to be checked on site and verified prior to commencing the works.
2830
LIVING 600X600mm CERAMIC TILE
TL-01b WOOD DESIGN - BROWN
(FLOOR)
3 3 TL-04
(FLOOR)
3815
F.F.L
TL 05 ±0.00 m 300X300mm CERAMIC TILE -
-0.02 m BEDROOM 4 AREA: 24 sqm TL-07b LIGHT GRAY (FLOOR)
F.F.L F.F.L FD
FLOOR DRAIN
+0.01 m FD +0.01 m FD
F.F.L FD TL 04 F.F.L
TL 07
±0.00 m AREA: 11 sqm -0.02 m TL 00 FLOOR FINISH CODE
STORAGE/TREADMILL TOILET
TL 01b
AREA: 7 sqm F.F.L TOILET & BATH
F.F.L
TL 06 ±0.00 m FD ±0.00 m
FINISH FLOOR LEVEL
4 F.F.L F.F.L
F.F.L
+0.01 m 4 DN
FD
FD
FD
DRAWING STATUS
2695
TL 01b
BEDROOM 2 BEDROOM 1 BALCONY
AREA: 22 sqm 00 ISSUED FOR APPROVAL 19-03-21 RB -
DRAWN CHECK
TL 01a REV. DESCRIPTION DATE
BY
AREA: 7.2 sqm AREA: 7.2 sqm BY
CONSULTANT:
TL 02
5 AREA: 4 sqm
5
F.F.L CLIENT:
TL 01a
±0.00 m UP UP
MINA S. CRUZ
LAUNDRY AREA
2705
2705
F.F.L
BEDROOM 3 -0.20 m
PROJECT TITLE:
6 6 DRAWING TITLE:
TWO-STOREY HOUSE
PROPOSED FLOORING
LAYOUT
Initials Signed by: Date:
Drawn by: RB 19-03-21
Checked by: -
1 PROPOSED FLOORING LAYOUT- GROUND FLOOR 2 PROPOSED FLOORING LAYOUT - SECOND FLOOR Approved by:
Scale:
-
AS SHOWN
SHEET SIZE A3
50 x 50 mm SQUARE
50
GENERAL NOTES:
TUBULAR BLACK METAL 50 x 50 mm SQUARE
TUBULAR BLACK METAL 1. Do not scale this drawing, use figured dimensions only.
50 2. This drawing has been prepared based upon survey and information supplied by others. All
dimensions and levels are to be checked on site by contractors and inconsistencies reported
2150
100
immediately to the Designer and Client prior to works being undertaken.
3. Contractors are to ensure that all works under their responsibility or the responsibility of their
100
sub-contractors are constructed and / or manufactured to comply with all relevant national and / or
BALCONY FLOOR LEVEL 50 local authority statutory requirements and in accordance with local building control and codes of
practice.
100
4. This drawing is to be read in conjunction with other relevant drawings, specifications, schedules
100
5 5 5 5 5 5 50
and so forth,relating to the project or projects from which this drawing has been prepared.
5 mm THK x 30 mm WIDTH 5. This drawing is also to be read in conjunction with drawings, specification, schedules and so forth
100
BLACK METAL FLAT BAR 6. This drawing is representative of design intent only, Contractor to supply for approval by the
100
900
7. The dimensional accuracy of this drawing as it relates to site conditions is not guaranteed. The
BLACK METAL FLAT BAR contractor must verify all site dimensions prior to producing shop and setting out drawings.
8. Refer to specification documents for all finish descriptions.
9. See detailed design per item; Verify actual measurement on site before installation, based on
900
approved materials and detailed specifications.
220
GROUND LEVEL BALCONY FLOOR LEVEL ABBREVIATIONS:
DRAWING STATUS
DRAWN CHECK
REV. DESCRIPTION DATE
BY BY
CONSULTANT:
CLIENT:
MINA S. CRUZ
PROJECT TITLE:
DRAWING TITLE:
TWO-STOREY HOUSE
HANDRAIL DETAILS
Initials Signed by: Date:
Drawn by: RB 19-03-21
Checked by: -
Approved by: - SHEET SIZE A3
Scale: AS SHOWN
NOTE: ALL DIMENSIONS TO BE MEASURED AND CONFIRMED ON SITE BEFORE PRODUCTION
DWG-ID-04 00
KEY PLAN:
20
dimensions and levels are to be checked on site by contractors and inconsistencies reported
immediately to the Designer and Client prior to works being undertaken.
3. Contractors are to ensure that all works under their responsibility or the responsibility of their
sub-contractors are constructed and / or manufactured to comply with all relevant national and / or
70
400
local authority statutory requirements and in accordance with local building control and codes of
practice.
30
4. This drawing is to be read in conjunction with other relevant drawings, specifications, schedules
30
600
and so forth,relating to the project or projects from which this drawing has been prepared.
5. This drawing is also to be read in conjunction with drawings, specification, schedules and so forth
prepared by others and which are relevant to the project or project identified on this drawing.
OPEN SHELF 6. This drawing is representative of design intent only, Contractor to supply for approval by the
350
960
Designer and Client, shop drawings and setting out rods to fully illustrate methods of construction
of all millworks, casegoods, joinery works and other specialist finishes and features.
7. The dimensional accuracy of this drawing as it relates to site conditions is not guaranteed. The
contractor must verify all site dimensions prior to producing shop and setting out drawings.
8. Refer to specification documents for all finish descriptions.
9. See detailed design per item; Verify actual measurement on site before installation, based on
1350 600
A OVERHEAD CABINET OVERHEAD CABINET approved materials and detailed specifications.
360
OPEN SHELF This drawing is the property of the Client.
Copyright is reserved by them and this drawing is issued on condition that is not copied or disclosed
-
FOR HOOD by or to any anauthorized persons without the prior consent in writing of the Client.
This drawing is not to be scaled for the purposes of setting-out.
Dimension to be checked on site and verified prior to commencing the works.
ABBREVIATIONS:
2450
640
- 2550 5 5
F.F.L = FINISH FLOOR LEVEL
F.C.L = FINISH CEILING LEVEL
S.C.L = SCREED LEVEL
B
5
30 20
LEGEND:
50
50
350
1200
30
600
600
250
1100
1050
250
2550
D
- KITCHEN COUNTER TOP BAR COUNTER TOP
150
150
150
OPEN SHELF
DRAWING STATUS
OPEN SHELF
840
840
840
OPEN SHELF
1090
1120
1120
1120
1120
1120
OPEN SHELF
OPEN SHELF 00 ISSUED FOR APPROVAL 15-02-21 RB -
30
DRAWN CHECK
REV. DESCRIPTION DATE
BY BY
600 CONSULTANT:
OPEN SHELF
30
30
620
2770
400 400
2770
2550
400
400
600 1350 600 600 65 600 360 640 600
600
600
CLIENT:
50
200 50
50
MINA S. CRUZ
30 200 30 200 30
30
150
150
30 150
250
150 150 150
150
125
510 510
1780
20
20
20
30
DRAWER DRAWER
30
PROJECT TITLE:
260 REMOVABLE
200
530 EQ EQ 510 510 PANEL 305
DRAWER DRAWER DRAWER W/
PROPOSED
1100
1100
920
30
PROVIDE
1050
MAGNETIC TWO-STOREY HOUSE
670
750
750
2-LEVEL
900
900
900
880
460
METAL RACK
330
TWO-STOREY HOUSE
100
100
100
100
DETAIL - KITCHEN & BAR
BUILT-IN CABINET
ELEVATION A ELEVATION B ELEVATION C
Signed by:
2 3 4 Drawn by:
Initials
RB
Date:
15-02-21
DWG-ID-05a 00
KEY PLAN:
GENERAL NOTES:
ABBREVIATIONS:
LEGEND:
DRAWING STATUS
DRAWN CHECK
REV. DESCRIPTION DATE
BY BY
CONSULTANT:
CLIENT:
MINA S. CRUZ
1 3D VIEW 1 2 3D VIEW 2
DWG-ID-05b SCALE DWG-ID-05b SCALE
PROJECT TITLE:
PROPOSED
TWO-STOREY HOUSE
TAPULAO, ORANI. BATAAN
DRAWING TITLE:
TWO-STOREY HOUSE
DETAIL - KITCHEN & BAR
BUILT-IN CABINET
NOTE: ALL DIMENSIONS TO BE MEASURED AND CONFIRMED ON SITE BEFORE PRODUCTION Initials Signed by: Date:
Drawn by: RB 15-02-21
CABINET MATERIAL: PLYWOOD SANDED AND PAINTED IN DARK GRAY SEMI-GLOSS Checked by: -
Approved by: - SHEET SIZE A3
COUNTERTOP MATERIAL: SYNTHETIC SOLID SURFACE OR GRANITE (LIGHT GRAY) Scale: AS SHOWN
DWG-ID-05b 00
KEY PLAN:
30
CABINET PANEL, GENERAL NOTES:
80
CARCASS, BED, AND 1. Do not scale this drawing, use figured dimensions only.
2. This drawing has been prepared based upon survey and information supplied by others. All
100
dimensions and levels are to be checked on site by contractors and inconsistencies reported
400
SHELVES MATERIAL:
50
immediately to the Designer and Client prior to works being undertaken.
20
3. Contractors are to ensure that all works under their responsibility or the responsibility of their
30
600
sub-contractors are constructed and / or manufactured to comply with all relevant national and / or
30
PLYWOOD PLASTERED,
local authority statutory requirements and in accordance with local building control and codes of
practice.
4. This drawing is to be read in conjunction with other relevant drawings, specifications, schedules
and so forth,relating to the project or projects from which this drawing has been prepared.
200
SANDED, AND PAINTED 5. This drawing is also to be read in conjunction with drawings, specification, schedules and so forth
prepared by others and which are relevant to the project or project identified on this drawing.
6. This drawing is representative of design intent only, Contractor to supply for approval by the
Designer and Client, shop drawings and setting out rods to fully illustrate methods of construction
IN WHITE SEMI-GLOSS of all millworks, casegoods, joinery works and other specialist finishes and features.
7. The dimensional accuracy of this drawing as it relates to site conditions is not guaranteed. The
contractor must verify all site dimensions prior to producing shop and setting out drawings.
8. Refer to specification documents for all finish descriptions.
9. See detailed design per item; Verify actual measurement on site before installation, based on
approved materials and detailed specifications.
A CABINET - UPPER PANEL 20 CABINET INNER This drawing is the property of the Client.
Copyright is reserved by them and this drawing is issued on condition that is not copied or disclosed
by or to any anauthorized persons without the prior consent in writing of the Client.
SHELVING: MELAMINE
240
This drawing is not to be scaled for the purposes of setting-out.
- Dimension to be checked on site and verified prior to commencing the works.
50 1000
WHITE ABBREVIATIONS:
2820
50
20
F.F.L = FINISH FLOOR LEVEL
1910
F.C.L = FINISH CEILING LEVEL
HINGES: FULL AND HALF
2420
S.C.L = SCREED LEVEL
30
OVERLAY HINGES LEGEND:
30
DRAWER GUIDE: BALL
100
BEARING DRAWER
SLIDE GUIDE
310
50
1 6
20
DWG-ID-07a SCALE DWG-ID-07a SCALE
CABINET - DRAWER
20
20
20
40
40
40
400
400
400
470
470
470
DRAWING STATUS
100
100
100
50
30
30
30
300
445
445
00 ISSUED FOR APPROVAL 21-01-21 RB -
630
630
DRAWN CHECK
50
CONSULTANT:
20
20
300
1120
1120
1120
20
20
50
2630
2630
350
350
2770
2770
2770
2770
300
2730
CLIENT:
MINA S. CRUZ
50
20
20
2150
2150
2150
30
30
30
300
350
350
1645
PROJECT TITLE:
1700
1700
20
20
DRAWER
PROPOSED
180 180
DRAWER
TWO-STOREY HOUSE
350
350
1000
1000
1000
20
20
900
20
80
DRAWER
30
DRAWING TITLE:
350
350
300
DRAWER
TWO-STOREY HOUSE
450
DRAWER
100 240
DETAIL - BEDROOM 1
20
20
20
20
100
100
100
100
100
BUILT-IN CABINET & BED
Initials Signed by: Date:
Drawn by: RB 21-01-21
DWG-ID-07a SCALE DWG-ID-07a SCALE DWG-ID-07a SCALE DWG-ID-07a SCALE Scale: AS SHOWN
DWG-ID-07a 00
KEY PLAN:
470
470
400 400
50
50
300
300
GENERAL NOTES:
50
50
1. Do not scale this drawing, use figured dimensions only.
300
300
2. This drawing has been prepared based upon survey and information supplied by others. All
dimensions and levels are to be checked on site by contractors and inconsistencies reported
immediately to the Designer and Client prior to works being undertaken.
3. Contractors are to ensure that all works under their responsibility or the responsibility of their
50 sub-contractors are constructed and / or manufactured to comply with all relevant national and / or
50
local authority statutory requirements and in accordance with local building control and codes of
practice.
4. This drawing is to be read in conjunction with other relevant drawings, specifications, schedules
and so forth,relating to the project or projects from which this drawing has been prepared.
2770
2770
300
300
5. This drawing is also to be read in conjunction with drawings, specification, schedules and so forth
prepared by others and which are relevant to the project or project identified on this drawing.
6. This drawing is representative of design intent only, Contractor to supply for approval by the
Designer and Client, shop drawings and setting out rods to fully illustrate methods of construction
50
50
of all millworks, casegoods, joinery works and other specialist finishes and features.
7. The dimensional accuracy of this drawing as it relates to site conditions is not guaranteed. The
contractor must verify all site dimensions prior to producing shop and setting out drawings.
8. Refer to specification documents for all finish descriptions.
300
300
9. See detailed design per item; Verify actual measurement on site before installation, based on
400 400 approved materials and detailed specifications.
900
30
F.F.L = FINISH FLOOR LEVEL
80
450
240
LEGEND:
100
DRAWING STATUS
DRAWN CHECK
REV. DESCRIPTION DATE
BY BY
CONSULTANT:
CLIENT:
MINA S. CRUZ
PROJECT TITLE:
PROPOSED
TWO-STOREY HOUSE
TAPULAO, ORANI. BATAAN
DRAWING TITLE:
TWO-STOREY HOUSE
DETAIL - BEDROOM 1
BUILT-IN CABINET & BED
Initials Signed by: Date:
Drawn by: RB 21-01-21
Checked by: -
DWG-ID-07b SCALE
DWG-ID-07b 00
KEY PLAN:
30
CABINET PANEL,
50
GENERAL NOTES:
80
CARCASS, BED, AND 1. Do not scale this drawing, use figured dimensions only.
40 30
2. This drawing has been prepared based upon survey and information supplied by others. All
dimensions and levels are to be checked on site by contractors and inconsistencies reported
400
SHELVES MATERIAL:
50
immediately to the Designer and Client prior to works being undertaken.
20
60 3. Contractors are to ensure that all works under their responsibility or the responsibility of their
80
600
sub-contractors are constructed and / or manufactured to comply with all relevant national and / or
30
PLYWOOD PLASTERED,
local authority statutory requirements and in accordance with local building control and codes of
practice.
4. This drawing is to be read in conjunction with other relevant drawings, specifications, schedules
and so forth,relating to the project or projects from which this drawing has been prepared.
200
30 570
SANDED, AND PAINTED 5. This drawing is also to be read in conjunction with drawings, specification, schedules and so forth
prepared by others and which are relevant to the project or project identified on this drawing.
30 6. This drawing is representative of design intent only, Contractor to supply for approval by the
Designer and Client, shop drawings and setting out rods to fully illustrate methods of construction
IN WHITE SEMI-GLOSS of all millworks, casegoods, joinery works and other specialist finishes and features.
7. The dimensional accuracy of this drawing as it relates to site conditions is not guaranteed. The
contractor must verify all site dimensions prior to producing shop and setting out drawings.
8. Refer to specification documents for all finish descriptions.
9. See detailed design per item; Verify actual measurement on site before installation, based on
approved materials and detailed specifications.
A CABINET - TWO-PANEL 20 CABINET INNER This drawing is the property of the Client.
Copyright is reserved by them and this drawing is issued on condition that is not copied or disclosed
by or to any anauthorized persons without the prior consent in writing of the Client.
SHELVING: MELAMINE
240
This drawing is not to be scaled for the purposes of setting-out.
- Dimension to be checked on site and verified prior to commencing the works.
WHITE ABBREVIATIONS:
2805
50
20
1000 50 F.F.L = FINISH FLOOR LEVEL
1910
20 LAMINATE/MELAMINE AS LEGEND:
20
100
HINGES: FULL AND HALF
30
OVERLAY HINGES
50
1 6
20
DWG-ID-08a SCALE DWG-ID-08a SCALE
CABINET - DRAWER
20
20
20
40
40
40
40
220
320
320
20 EQ
20 EQ
DRAWING STATUS
20
20
450
SHELF
20 EQ
20 EQ
1070
1070
1070
320
320
1080
50
20
20
00 ISSUED FOR APPROVAL 21-01-21 RB -
20 EQ
20 EQ
DRAWN CHECK
320
320
REV. DESCRIPTION DATE
450
350
BY BY
SHELF
CONSULTANT:
80
80
50
30
50
50
2650
2650
2630
2630
450
510
450
350
510
450
350
510
2770
2770
2770
2770
SHELF SHELF SHELF SHELF
2730
CLIENT:
MINA S. CRUZ
50
50
30
80
80
300
320
320
1645
PROJECT TITLE:
1700
1700
PROPOSED
20
20
DRAWER
180 180
DRAWER
1080
TWO-STOREY HOUSE
1070
1070
1070
320
320
20
20
20
20
80
DRAWER
30
DRAWING TITLE:
300
320
320
DRAWER
TWO-STOREY HOUSE
450
DRAWER
100 240
DETAIL - BEDROOM 2
20
20
20
20
100
100
100
100
100
100
BUILT-IN CABINET & BED
Initials Signed by: Date:
Drawn by: RB 21-01-21
DWG-ID-08a SCALE DWG-ID-08a SCALE DWG-ID-08a SCALE DWG-ID-08a SCALE Scale: AS SHOWN
DWG-ID-08a 00
KEY PLAN:
220
220
400
450
450
GENERAL NOTES:
450
450
1. Do not scale this drawing, use figured dimensions only.
2. This drawing has been prepared based upon survey and information supplied by others. All
dimensions and levels are to be checked on site by contractors and inconsistencies reported
immediately to the Designer and Client prior to works being undertaken.
3. Contractors are to ensure that all works under their responsibility or the responsibility of their
sub-contractors are constructed and / or manufactured to comply with all relevant national and / or
local authority statutory requirements and in accordance with local building control and codes of
practice.
4. This drawing is to be read in conjunction with other relevant drawings, specifications, schedules
450
450
and so forth,relating to the project or projects from which this drawing has been prepared.
2770
2770
5. This drawing is also to be read in conjunction with drawings, specification, schedules and so forth
prepared by others and which are relevant to the project or project identified on this drawing.
6. This drawing is representative of design intent only, Contractor to supply for approval by the
Designer and Client, shop drawings and setting out rods to fully illustrate methods of construction
of all millworks, casegoods, joinery works and other specialist finishes and features.
7. The dimensional accuracy of this drawing as it relates to site conditions is not guaranteed. The
contractor must verify all site dimensions prior to producing shop and setting out drawings.
8. Refer to specification documents for all finish descriptions.
300
300
9. See detailed design per item; Verify actual measurement on site before installation, based on
400 400 approved materials and detailed specifications.
900
900
30
F.F.L = FINISH FLOOR LEVEL
80
F.C.L = FINISH CEILING LEVEL
30
S.C.L = SCREED LEVEL
DRAWER DRAWER DRAWER
270
450
450
240
LEGEND:
100
1 BUILT-IN BED & SHELVES SIDE ELEVATION 2 SECTION D
DWG-ID-08b SCALE DWG-ID-08b SCALE
DRAWING STATUS
DRAWN CHECK
REV. DESCRIPTION DATE
BY BY
CONSULTANT:
CLIENT:
MINA S. CRUZ
PROJECT TITLE:
PROPOSED
TWO-STOREY HOUSE
TAPULAO, ORANI. BATAAN
DRAWING TITLE:
TWO-STOREY HOUSE
DETAIL - BEDROOM 2
BUILT-IN CABINET & BED
Initials Signed by: Date:
Drawn by: RB 21-01-21
Checked by: -
DWG-ID-08b SCALE
DWG-ID-08b 00
KEY PLAN:
SANDED, AND PAINTED IN WHITE 2. This drawing has been prepared based upon survey and information supplied by others. All
50
dimensions and levels are to be checked on site by contractors and inconsistencies reported
20
immediately to the Designer and Client prior to works being undertaken.
1566
SEMI-GLOSS 3. Contractors are to ensure that all works under their responsibility or the responsibility of their
sub-contractors are constructed and / or manufactured to comply with all relevant national and / or
local authority statutory requirements and in accordance with local building control and codes of
practice.
4. This drawing is to be read in conjunction with other relevant drawings, specifications, schedules
and so forth,relating to the project or projects from which this drawing has been prepared.
5. This drawing is also to be read in conjunction with drawings, specification, schedules and so forth
WHITE 7. The dimensional accuracy of this drawing as it relates to site conditions is not guaranteed. The
contractor must verify all site dimensions prior to producing shop and setting out drawings.
8. Refer to specification documents for all finish descriptions.
600
9. See detailed design per item; Verify actual measurement on site before installation, based on
approved materials and detailed specifications.
HINGES: FULL AND HALF OVERLAY HINGES Copyright is reserved by them and this drawing is issued on condition that is not copied or disclosed
by or to any anauthorized persons without the prior consent in writing of the Client.
This drawing is not to be scaled for the purposes of setting-out.
Dimension to be checked on site and verified prior to commencing the works.
967
1550
ABBREVIATIONS:
DRAWER GUIDE: BALL BEARING DRAWER
50
20
SLIDE GUIDE F.F.L = FINISH FLOOR LEVEL
F.C.L = FINISH CEILING LEVEL
950
S.C.L = SCREED LEVEL
A LEGEND:
-
30
600
30
20
1 P L A N
DWG-ID-09a SCALE
CABINET - PANEL
50
20
250
250
250
20
20
40
40
40
40
40
40
DRAWING STATUS
20 300 20 300 20 300 20 300 20 300 20 300
328
328
20
20
20
00 ISSUED FOR APPROVAL 21-01-21 RB -
348
348
348
DRAWN CHECK
1270
1270
REV. DESCRIPTION DATE
BY BY
20
20
20
CONSULTANT:
2770
2770
2770
2770
2420
2420
2420
2420
2420
2420
2400
2360
2360
2400
2360
CLIENT:
2520
30
30
MINA S. CRUZ
1645
1645
1645
PROJECT TITLE:
1700
1700
1700
DRAWER DRAWER PROPOSED
180 180
DRAWER
1100
1100
TWO-STOREY HOUSE
20
DRAWER DRAWER TAPULAO, ORANI. BATAAN
700
DRAWER
20
440
440
440
DRAWING TITLE:
300
DRAWER DRAWER
DRAWER TWO-STOREY HOUSE
DETAIL - BEDROOM 3
20
20
20
20
20
20
20
100
100
100
100
100
100
100
100
BUILT-IN CABINET & BED
Initials Signed by: Date:
Drawn by: RB 21-01-21
DWG-ID-09a 00
KEY PLAN:
B
-
30
GENERAL NOTES:
BEFORE PRODUCTION
400
80
1. Do not scale this drawing, use figured dimensions only.
2. This drawing has been prepared based upon survey and information supplied by others. All
dimensions and levels are to be checked on site by contractors and inconsistencies reported
immediately to the Designer and Client prior to works being undertaken.
3. Contractors are to ensure that all works under their responsibility or the responsibility of their
sub-contractors are constructed and / or manufactured to comply with all relevant national and / or
1378 local authority statutory requirements and in accordance with local building control and codes of
EQ
CABINET PANEL, practice.
30
4. This drawing is to be read in conjunction with other relevant drawings, specifications, schedules
and so forth,relating to the project or projects from which this drawing has been prepared.
1100 SHELVES MATERIAL: of all millworks, casegoods, joinery works and other specialist finishes and features.
7. The dimensional accuracy of this drawing as it relates to site conditions is not guaranteed. The
contractor must verify all site dimensions prior to producing shop and setting out drawings.
8. Refer to specification documents for all finish descriptions.
PLYWOOD PLASTERED, 9. See detailed design per item; Verify actual measurement on site before installation, based on
approved materials and detailed specifications.
2657
Dimension to be checked on site and verified prior to commencing the works.
240
ABBREVIATIONS:
2290
1910
- WHITE LEGEND:
6 3D VIEW
DWG-ID-09b SCALE
470
470
470
DRAWING STATUS
400 400
50
50
50
300
300
300
00 ISSUED FOR APPROVAL 21-01-21 RB -
50
50
50
DRAWN CHECK
REV. DESCRIPTION DATE
BY BY
300
300
300
CONSULTANT:
50
50
50
2770
2770
2770
300
300
300
CLIENT:
50
50
50
MINA S. CRUZ
300
300
300
400 400
PROJECT TITLE:
900
900
30
80
80
30
30
DRAWING TITLE:
270
450
450
100 240
240
DWG-ID-09b 00
KEY PLAN:
3660
1030 1600 1030
515
NOTE: ALL DIMENSIONS TO BE MEASURED AND CONFIRMED ON SITE BEFORE
PRODUCTION
CABINET PANEL AND CARCASS MATERIAL: PLYWOOD PLASTERED, SANDED, AND
PAINTED IN WHITE SEMI-GLOSS
CABINET INNER SHELVING: MELAMINE WHITE
570
600
OPEN SHELVES: PLYWOOD PLASTERED, SANDED, AND PAINTED IN DARK GRAY GENERAL NOTES:
ABBREVIATIONS:
50
50
40
100
40
F.F.L = FINISH FLOOR LEVEL
F.C.L = FINISH CEILING LEVEL
S.C.L = SCREED LEVEL
455
LEGEND:
SHELF
40 240 40 240 40
1350
SHELF
SHELF
2250
2170
2250
2400
515
100
SHELF
40 240 40 200 40
800
SHELF
SHELF
40
100
100
DRAWING STATUS
50
50
50
50
50
70
90
20 300 20 300 20 300 20 300 20 300 20 300 20 290 20
40
100
40
40
00 ISSUED FOR APPROVAL 21-01-21 RB -
455
455
DRAWN CHECK
REV. DESCRIPTION DATE
BY BY
SHELF SHELF
10 CONSULTANT:
40 240 40 240 40
40 240 40 240 40
20
1350
1250
SHELF SHELF
20
CLIENT:
2170
2250
2250
2250
2170
2250
2210
2400
2400
2400
PROJECT TITLE:
515
515
100
PROPOSED
SHELF SHELF
FULL HEIGHT CABINET TWO-STOREY HOUSE
PANEL FINGER-PULL
40 240 40 200 40
40 240 40 200 40
TAPULAO, ORANI. BATAAN
800
SHELF SHELF
HANDLE DRAWING TITLE:
TWO-STOREY HOUSE
SHELF SHELF 6 DETAIL DETAIL - BEDROOM 4 BUILT-IN
DWG-ID-10a SCALE HEADBOARD CABINET
40
40
100
100
100
100
100
100
Initials Signed by: Date:
Drawn by: RB 21-01-21
Checked by: -
Approved by: - SHEET SIZE A3
3 ELEVATION (OPEN) 4 SECTION A 5 SECTION B Scale: AS SHOWN