You are on page 1of 6

EN/LZT 720 0150 R1B

RBS 2101

Interface
Quick Guide

Mounting Base Interfaces


Alarm

Site Installation
Documentation

External
alarm cables

Overvoltage Protector (OVP)


External Alarms
Connection Unit (EACU)

Reserved for
future use
7 8

External
alarm cables
5 6
3 4

8
7
1 2

P007637B

1 (6)
Interface RBS 2101

AC Mains

0
1

AC Mains

Warning
Remove the cable before 230 V AC
connecting to Mains supply.
Single-phase.

N
N

N
L3

N
L3/
L2

L1
1

L
L1

L
T
0

L1/L Jumper
PE Position 1
P

240/120 V AC
Single-phase, three-wire, earthed midpoint.
N

N
L3

L2
T

N
L3/
L2

L1
1

L
PE L1

L
T

Jumper
0

Position 1
P
P

Single-phase, four-wire, separate PE and N conductor.

N N
N

L2 L3
L3

L
L2

L1
1

Jumper
L1

L
T

Position 1
0

PE
P

2 (6) EN/LZT 720 0150 R1B


RBS 2101 Interface

Cabinet Interfaces
Feeder / Jumper Connections
TX1

TX2

RX1

RX2

Connector Jumper cable Jumper cable Jumper cable


RPT 403 173/01 TSR 951 70/2 TSR 951 70/2 TSR 951 70/2

Feeder cable Connector Connector Connector


1/2” RNT 403 060/001 RNT 403 061/001 RNT 403 062/001
TZC 501 26
Feeder cable Feeder cable Feeder cable
7/8” 1 1/4” 1 5/8”
TZC 501 22 TZC 501 27 TZC 501 28

Alternatives

Feeder/Jumper
cables

EN/LZT 720 0150 R1B 3 (6)


Interface RBS 2101

Front connection field,


Transmission seen from below
G.703-2 G.703-1

BUS-1 BUS-2

-48V
+24V
RPM 53 1294/01500

75W RPM 513 756/01000


100W RPM 513 758/01000
120W RPM 513 755/01000 1234

Connection fields,
Mounting Base

External Alarm
TX1
Connection field TX2
seen from below
RX1
RX2

DOOR EXT. EXT.T TM TM


ALARM -48 V +24 V
Not used
RPM 513 1399/00800
RPM 251 13/00600

RPM 513 931/01400

Connection fields,
Mounting Base

4 (6) EN/LZT 720 0150 R1B


RBS 2101 Interface

+24 V DC (Option) Rear connection field,


seen from below

+ L3 T3 +
24 V DC L2 L2
L1 T1

AC Mains
Front connection field,
seen from below 1 2 3
4
G.703-2 G.703-1

BUS-1 BUS-2
RPM 513 909/00450
RPM 513 913/00700 RPM 513 909/01600
RPM 513 909/00450

PSU1
ECU
CLIM.
PSU2

EN/LZT 720 0150 R1B 5 (6)


Interface RBS 2101

Master Extension

RPM 513 745/nnnnn

RX1 RX1
TX1 Master Cabinet TX1 Extension Cabinet
BUS1 BUS2 BUS1 BUS2

RPM 513 1293/nnnnn

nnnnn= cable length in mm

Condensed information, for experienced users, based on the respective product’s Installation and Integration Manual.

The contents of this document are subject to revision without notice due
Ericsson AB to continued progress in methodology, design and manufacturing.
SE-164 80 Stockholm Ericsson shall have no liability for any error or damages of any kind resulting
Sweden from the use of this document.
implementation.GSMsupport@era.ericsson.se © Ericsson AB 2003 - All Rights Reserved
6 (6) EN/LZT 720 0150 R1B