EP27, Ep29 AC Voltmeters 3 Phase 3 Wire

moving-iron voltmeters L2

L1
L3

with a change-over switch L1 L


O
L2 A
AC Voltmeters
L3 3 Phase 3 Wire D

AC Voltmeters L3 4 Wire
3 Phase
L2

Category of climate versions L1L2 L3

If it is not stipulated in another way, theseL1 meters are destined


N
to be applied in closed rooms, without air conditioning systems
and in conditions L
L1of a moderate climate, acc. EN 60051 standard.
On customers request, theseL1 meters can be adapted to be O
applied
L2 AL
in dry or wet tropical climate
L2 conditions, and also in closed rooms
L3 DO
without air conditioning.Then, they are marked with the TIII symbol.
A
L3
D
N
APPLICATION AC Voltmeters 3 Phase 4 Wire
The EP27 and EP29 moving-iron panel voltmeter with a change-over OVERALL DIMENSIONS
switch is adapted for measuring line-to-line and phase-to-phase RMS Dimensions
L2
L3
64
f
voltages in 3-phase 4-wire power networks. L1
A six-positional switch installed on the meter frontal side enables N
the choice of the measured voltage in six different points
of the network system.
L1 L

x a2
x I2
a172
I1 68
TECHNICAL DATA L2 O
L3 A
Frontal frame: D
- EP27 72 ´ 72 ´ 64 mm
N
- EP29 96 ´ 96 ´ 64 mm
5,5
h
Accuracy class 1.5 EP27 53
t

Measuring range:
Dimensions
64
f
- for direct interfacial Front Nominal Cutout, mm Installation Installation Depth Incl.
in mm Dimensions, mm
connection (at the position I1 x I2 Depth Including Full back Cover (f),
a1 x a 2 h Terminal (t), mm mm
of the switch on L1-N, L2-N
or L3-N) 500 V max. 300 V 72 x 72 72 x 72 5.5 68 x 68
+0.7 +0.7
53 64
+0.8 +0.8
- through a voltage 96 x 96 96 x 96 5.5 92 x 92 53 64
transformer x/110 V or x/100 V
a1 x96a2
I1 x92I 2

Working position given on the meter ± 5°


Panel material any
Additional errors within
the limits of rated operating
conditions acc. to EN 60051-2
Power consumption
- EP27 max. 4.5 VA (Un = 500 V) 5,5
h t
53
- EP29 max. 4.5 VA (Un = 500 V)
EP29
Protecion degree acc. to EN 60529
- ensured by the housing IP40 and AVAILABLE
Codes Front Nominal WORKING
Cutout, mmPOSITIONS
Installation Installation Depth I
- from terminal side IP20 (with terminal cover) in mm Dimensions, mm
I1 x I2 Depth Including
Table 1 Full back Cover (f)
Electromagnetic compatibility: a1 x a 2 h Code
Terminal (t), mm mm
Working position
- immunity EN 61000-6-2 x0 68 c3
+0.7 +0.7 RI
72 x 72 72 x 72 5.5 68 53 64
- emission EN 61000-6-4 F-
96 x 96 96 x 96 5.5 92 xA
+0.8 +0.8 c1
92 53 64 Te
Safety requirements EN 61010-1 E-
B c2,  = 15°
EN 61010-1/A2 W
- installation category III C c2,  = 30°
- pollution level 2 D
www.rishabh.co.in c2,  = 45° Pa
- maximal working voltage E c2,  = 60°
in relation to the earth 300 V
F c2,  = 75°
Accessories H c4,  = 105°
- screw holders to fix the meter on the panel 2 pcs.
I c4,  = 120° 1

www.lumel.com.pl
fixing the meter in the panel
Panel cut-out for EP27: 68+0.7 ´ 68+0.7 mm
Panel cut-out for EP29: 92+0.8 ´ 92+0.8 mm

AC Voltmeters 3 Phase 3 Wire

L3
L2

L1

L1 L
Fig. 1.Fixing the meter EP27 and EP29 in the panel. O
L2 A
L3 D

AC Voltmeters 3 Phase 4 Wire


CONNECTION DIAGRAM
AC Voltmeters OF EXTERNAL
3 Phase 3 Wire CIRCUITS Ordering Information
L3
L2
L3
L2 Type EQ SWT Moving-iron panel meter
L1
L1 Front dimension N
72 72 mm x 72 mm
96 96 mm x 96 mm

L Over range
L1 no over range *3
L1 (ammeters) L *1
2 times nominal current
O L2 O *3
L2 6 times nominal current
A A
D L3
L3 Measuring Ranges Refer to table inside D
N
Terminal protection full sized polycarbonate backcover
Voltage
AC measurement
Voltmeters in 3-phase
3 Phase 4 Wire 3-wire network Voltage measurement in 3-phase 4-wire network
Panel Fixing Swivel Screw

ordering code L2
L3
Dimensions
Red Index Pointer None *1
Table 2
Me-
Front facia Normal glassf*1
L1 Range
EP27 and EP29 - X XXXX X XX X asuring Transformer
code
AntiglareRange
Transformer glass *3Transformer
code
Range
code
N range

Climatic version: 1 kV Colour


1000/100Vof bezel
C700 Black *1
normal N 7.5 kV 7500/100V C701
Red,Blue,Yellow
6000/100V C742
,White*3
smiliar toL1
amrine M L Position Vertical C752 10 000/100V E703
6000/100V of C702
use *1
10 kV 6000/57.7V
tropical L2 T O On request 0
0
.... 180
*3
10 000/110V
0
E803
A
a 1 x a2

Ranges:L3
I1 x I 2

15 kV 10 000/100V C703 15 000/100V E704 15 000/110V E804


write the range code from the table 2 D
XXXX Dial Standard scale same as measuring range *1
N 17.5kV 15 000/100V C704
Blank dial with division *3
Operating position: 40 kV 30 000/100V E707 35 000/100V C707 30 000/110V E807*3
Additional lettering on request
acc. to table 1 X 50 kV 50 000/100V C708
Additional numbering on request
*3 O
Version: 2.5 kV 2500/100V C718 Coloured marking red or green *3

Dimensions
standard 00 25 kV 25 000/100V C720 ColouredC722
22 000/100V sector20000/57.7V
red or green
C756
*3 E
custom-made1) f XX
18 kV 15 000/100V C721
Acceptance tests: Logo RISHABH , t
h
*1
for Indian sales
132 kV 110000/100V C723
without a quality inspection certificate 0 C.G.*1, for export through
150 000/100V
with an extra quality inspection certificate 1 150 kV 100000/100V C724 CromptonE709 Grea150 000/110V
ves I.D.
E809
110 000/100V *3 E723 110 000/110V E823
according to customer’s request 2 Others
Front
110 kV Nominal
110000/100V C725 Cutout, mm
Installation Installation Depth Incl.
1)
aftger agreeing with the manufacturer in8 mm Dimensions, mm
kV *1 standard C733
6300/100V I16000/100V
Depth x I2
E721 Including Full back
6000/110V Cover (f),
E821
aPlease
1 x a 2 clearly
h Terminal (t), mm mm
a 1 x a2
I1 x I 2

*3 add the desired


250 000/100V E710 specifications
220 000/100V while
E724 ordering
250 kV 220000/100V C734
Odering example: 250
+0.7000/110V
+0.7 E810 220 000/110V E824
72 x 7240072
450 kV C735 68
x 72 5.5
000/100V x 68 53 64
The code EP27NC700C000 - means the meter of EP27 type: xOrdering x 96 example
+0.8 +0.8
96
400 kV 9630096
000/100V C736 92400 x
5.5 92
000/100V E711 53400 000/110V 64
E811
measuting range 1kV, for voltage transformer 1000/100V, ope-
7.2 kV 6000/100V C741
rating position 30o, without a auality inspection certificate.
12 kVEQ10
SWT 72
000/100V Measuring
C743 range 150 V, dial 0 - 100%
100 V E611
h t 500 V Specifications E615
are subject to change without notice (11/11)
XV X/100V E7
4 kV 3000/100V E701 3000/110V E801

Front Nominal Cutout, mm Installation Installation Depth Incl. 6 kV 6000/100V E702 6000/110V E802
in mm Dimensions, mm
I1 x I2 Depth Including Full back Cover (f),
20 kV 20 000/100V E705 15 000/100V E722
20 000/110V E805
a1 x a 2 h Terminal (t), mm mm 15 000/110V E822

+0.7 60 kV 60 000/100V E708 60 000/110V E808


+0.7
72 x 72 72 x 72 5.5 68 x 68 53 64 XV X/110V E8
+0.8 +0.8
96 x 96 96 x 96 5.5 92 x 92 53 64