DC SUPPLY
AUTO START & AUTO MAINS FAILURE CONTROL MODULES CONTINUOUS VOLTAGE RATING
8 V to 35 V Continuous
5 V for upto 1 minute
CRANKING DROPOUTS
Able to survive 0 V for 100 mS, providing
supply was at least 10 V before dropout and
supply recovers to 5 V. This is achieved
without the need for internal batteries.
LEDs and backlight will not be maintained
during cranking.
GENERATOR & MAINS (UTILITY)
VOLTAGE RANGE
15 V to 415 V AC (Ph to N)
26 V to 719 V AC (Ph to Ph)
FREQUENCY RANGE
3.5 Hz to 75 Hz
KEY FEATURES • Unbalanced load protection • Start & stop capability via SMS
• Configurable power-up mode • Independent earth fault protection messaging MAGNETIC PICKUP
VOLTAGE RANGE
• MPU fail delay • Breaker control via fascia buttons • 3 configurable maintenance alarms +/- 0.5 V to 70 V
• Enhanced graphical user interface • Fuel and start outputs configurable • Compatible with a wide range of
• Drag & drop advanced PLC editor when using CAN CAN engines, including tier 4 FREQUENCY RANGE
10,000 Hz (max)
• MSC ID within PLC GenComm • 6 configurable DC outputs engine support
override • 2 configurable volt-free relay • Uses DSE Configuration Suite PC INPUTS
• 4-Line back-lit LCD text display outputs Software for simplified DIGITAL INPUTS A TO H
Negative switching
• Multiple Display Languages • 6 configurable analogue/digital configuration
• Five key menu navigation inputs • Licence-free PC software ANALOGUE INPUTS A & F
• LCD alarm indication • Support for 0 V to 10 V & 4 mA to • IP65 rating (with supplied gasket) Configurable as:
• Heated display option available 20 mA sensors offers increased resistance to water Negative switching digital input
0 V to 10 V sensor
• Customisable power-up text and • 8 configurable digital inputs ingress 4 mA to 20 mA sensor
images • Configurable 5 stage dummy load • Modules can be integrated into Resistive sensor
• DSENet expansion compatibility and load shedding outputs building management systems
ANALOGUE INPUTS B, C, D & E
• Data logging facility • CAN, MPU and alternator (BMS) using MODBUS RTU Configurable as:
• Internal PLC editor frequency speed sensing in one Negative switching digital input
• Protections disable feature variant KEY BENEFITS Resistive sensor
• Fully configurable via PC using • Real time clock • Automatically transfers between
OUTPUTS
USB, RS232 & RS485 • Manual and automatic fuel pump mains (utility) and generator OUTPUT A & B (FUEL & START)
communication control (DSE7320 MKll only) for 15 A DC at supply voltage
• Front panel configuration with • Engine pre-heat and post-heat convenience.
OUTPUTS C & D
PIN protection functions • Hours counter provides accurate 8 A AC at 250 V AC (Volt-free)
• Power save mode • Engine run-time scheduler information for monitoring and
• 3 phase generator sensing and • Engine idle control for starting & maintenance periods AUXILIARY OUTPUTS E, F, G, H, I & J
stopping • User-friendly set-up and button 2 A DC at supply voltage
protection
• 3 phase mains (utility) sensing and • Fuel usage monitor and low fuel layout for ease of use DIMENSIONS
protection (DSE7320 MKII only) level alarms • Multiple parameters are monitored OVERALL
• Automatic load transfer control • Simultaneous use of RS232 and & displayed simultaneously for full 245 mm x 184 mm x 51 mm
9.6” x 7.2” x 2.0”
(DSE7320 MKII only) RS485 communication ports visibility
• Generator current and power • True dual mutual standby using • The module can be configured to PANEL CUT-OUT
monitoring (kW, kvar, kVA, pf) RS232 or RS485 for accurate suit a wide range of applications for 220 mm x 160 mm
8.7” x 6.3”
• Mains current and power engine hours balancing. user flexibility
monitoring (kW, kvar, kVA, pf) • MODBUS RTU support with • PLC editor allows user configurable MAXIMUM PANEL THICKNESS
(DSE7320 MKII only) configurable MODBUS pages. functions to meet user specific 8 mm
• kW and kvar overload and reverse • Advanced SMS messaging application requirements. 0.3”
power alarms (additional external modem STORAGE TEMPERATURE RANGE
• Over current protection required) -40°C to +85°C
-40 °F to +185 °F
Deep Sea Electronics Plc maintains a policy of continuous development and reserves the right to change Registered in England & Wales No.01319649
the details shown on this data sheet without prior notice. The contents are intended for guidance only. VAT No.316923457 055-203/12/20 (2)
DSEGenset®
ELECTRO-MAGNETIC COMPATIBILITY
SHOCK
BS EN 60068-2-27
Three shocks in each of three major axes
15 gn in 11 mS
DEGREES OF PROTECTION
PROVIDED BY ENCLOSURES
BS EN 60529
IP65 - Front of module when installed into the
control panel with the supplied sealing gasket.
DSENET ®
RS232 AND USB CONFIGURABLE DC OUTPUTS ANALOGUE EMERGENCY DC POWER
EXPANSION RS485 PORT INPUTS INPUT STOP SUPPLY 8-35V
DEUTZ
DSE7310/20 MKII ISUZU
PERKINS
CATERPILLAR
MTU
7 VOLVO
CUMMINS
OTHER SCANIA
MAINS (UTILITY) N/C VOLT FREE GENERATOR/ N/O VOLT FREE GENERATOR CHARGE FUEL & CRANK ELECTRONIC
SENSING OUTPUT LOAD CURRENT OUTPUT SENSING ALTERNATOR OUTPUTS ENGINES &
DSE7320 MKII ONLY (Flexible with CAN) MAGNETIC PICK-UP