Result: Report of Fondation Analysis Geotechnic
Result: Report of Fondation Analysis Geotechnic
Thereby attached the summary of foundation of Pileslab in KM 8. The output result are the pile length for abutment which have considered the
maximum axial responses (compression and tension) and lateral deflection.
In conclusion, all the design criteria have been fullfiled for pileslab. The safety factor has reached the requirement where:
a. In Abutment 4 type 1, the safety factor is 6.2 in static condition, 5.7 in earthquake condition of compression.
b. In Pier 2 type 1, the safety factor is 5.6 in static condition, 6.1 in earthquake condition of compression.
c. In Abutment 3 type 1, the safety factor is 6.1 in static condition, 5.0 in earthquake condition of compression, and 2.8 in earthquake condition of tension.
d. In Abutment 1 type 2, the safety factor is 5.8 in static condition, 5.0 in earthquake condition of compression.
he
dition of tension.
22
Pile Pile SingleRespond
Maximum
Single Pile
Foundation Structure Length Load Pile Lateral
Structure Type Ref Conf Axial
Type Type Axial Deformation
(m) Compression
(kN) (kN) (mm)
Tension
SLS 914 0 3.71
BH-03 2x9 CSP600 A3 12
ULS 1126 335 15.84
KM8
SLS 820 0 3.18
type2 BH-02 2x9 CSP600 A2 12
ULS 1151 359 16.05
Minimum Unused
Pile Test Dynamic
Hiley Formula (SF
SLS=2.5 & SF
(kN) (kN)
ULS=1.67)
2285
2285
1880
2050
2050
1922