You are on page 1of 8

Report of Fondation Analysis Geotechnic

Thereby attached the summary of foundation of Pileslab in KM 8. The output result are the pile length for abutment which have considered the
maximum axial responses (compression and tension) and lateral deflection.

Table 14 KM 8 Foundation Summary - Pileslab


Single Pile Single Pile Allowable Value
Ultimate Ultimate
Compression Tension Compression Tension Lateral
Structure Pile Length Load Bearing Calacity Bearing Safety Factor Pile Safety Factor
Structure Type Ref Conf Foundation Type Bearing Bearing Deformation
Type Calacity Criteria Capacity
Capacity

(m) (kN) (kN) Compression Tension (kN) (kN) (mm)


1x8 CSP600 A4 12 SLS 5610 953 2.5 6.2 2244 381 12.5
ULS 5610 953 1.67 5.7 3359 571 25
1x8 CSP600 P2 12 SLS 5610 953 2.5 5.6 2244 381 12.5
type 1 BH-03
ULS 5610 953 1.67 6.1 3359 571 25
2x9 CSP600 A3 12 SLS 5610 953 2.5 6.1 2244 381 12.5
ULS 5610 953 1.67 5.0 2.8 3359 571 25
1x7 CSP600 A1 12 SLS 5484 846 2.5 5.8 2193 338 12.5
ULS 5484 846 1.67 5.0 3284 507 25
1x7 CSP600 P1 12 SLS 5484 846 2.5 5.3 2193 338 12.5
type2 BH-02
ULS 5484 846 1.67 5.7 3284 507 25
2x9 CSP600 A2 12 SLS 5484 846 2.5 6.7 2193 338 12.5
ULS 5484 846 1.67 4.8 2.4 3284 507 25
KM8
BH-02 1x5 CSP600 A1 12 SLS 5484 846 2.5 6.3 2193 338 12.5
ULS 5484 846 1.67 5.4 3284 507 25
BH-03 1x5 CSP600 A4 12 SLS 5610 953 2.5 6.5 2244 381 12.5
ULS 5610 953 1.67 5.5 3359 571 25
BH-02 1x5 CSP600 P1 12 SLS 5484 846 2.5 5.7 2193 338 12.5
ULS 5484 846 1.67 5.5 3284 507 25
type 3
BH-03 1x5 CSP600 P2 12 SLS 5610 953 2.5 5.8 2244 381 12.5
ULS 5610 953 1.67 5.6 3359 571 25
BH-02 2x6 CSP600 A2 12 SLS 5484 846 2.5 7.0 2193 338 12.5
ULS 5484 846 1.67 5.1 2.3 3284 507 25
BH-03 2x6 CSP600 A3 12 SLS 5610 953 2.5 7.2 2244 571 12.5
ULS 5610 953 1.67 5.2 2.6 3359 571 25

In conclusion, all the design criteria have been fullfiled for pileslab. The safety factor has reached the requirement where:
a. In Abutment 4 type 1, the safety factor is 6.2 in static condition, 5.7 in earthquake condition of compression.
b. In Pier 2 type 1, the safety factor is 5.6 in static condition, 6.1 in earthquake condition of compression.
c. In Abutment 3 type 1, the safety factor is 6.1 in static condition, 5.0 in earthquake condition of compression, and 2.8 in earthquake condition of tension.
d. In Abutment 1 type 2, the safety factor is 5.8 in static condition, 5.0 in earthquake condition of compression.
he

Pile Maximum Respond

Single Pile Single Pile Lateral


C Axial . Axial Tension Deformation
ompress1on

(kN) (kN) (mm)


899 0 9.90
982 0 16.72
996 0 3.33
918 0 13.24
914 0 3.71
1126 335 15.84
951 0 4.05
1090 0 13.53
1029 0 2.83
960 0 13.79
820 0 3.18
1151 359 16.05
865 0 7.61
1011 0 15.68
865 0 7.61
1011 0 15.68
969 0 2.64
1003 0 12.13
969 0 2.64
1003 0 12.13
781 0 3.13
1085 365 14.08
781 0 3.13
1085 365 14.08

dition of tension.
22
Pile Pile SingleRespond
Maximum
Single Pile
Foundation Structure Length Load Pile Lateral
Structure Type Ref Conf Axial
Type Type Axial Deformation
(m) Compression
(kN) (kN) (mm)
Tension
SLS 914 0 3.71
BH-03 2x9 CSP600 A3 12
ULS 1126 335 15.84
KM8
SLS 820 0 3.18
type2 BH-02 2x9 CSP600 A2 12
ULS 1151 359 16.05
Minimum Unused
Pile Test Dynamic
Hiley Formula (SF
SLS=2.5 & SF
(kN) (kN)
ULS=1.67)
2285
2285
1880
2050
2050
1922