Professional Documents
Culture Documents
PEMELIHARAAN PROTEKSI
TRANSMISI
PT PLN (PERSERO) Gardu Induk : Semarang
UPDL SEMARANG Bay : Kedung Mundu
Tanggal : 10 Agustus 2022
Suwito Kelompok 1
Distance:
Test Module
Name: OMICRON Distance Version: 3.20
Test Start: 10-Aug-2022 11:13:43 Test End: 10-Aug-2022 11:14:01
User Name: KELOMPOK 1 Manager:
Company: PT. PLN (Persero)
Test Results
Shot Test: Fault Type R-N
|Z| Phi t nom t act. Dev. VTest Result
10,39 Ω 76,00 ° 425,0 ms 436,7 ms 2,753 % 100,0 V Passed
Test State:
Test passed
Distance:
Test Module
Name: OMICRON Distance Version: 3.20
Test Start: 10-Aug-2022 11:16:08 Test End: 10-Aug-2022 11:16:34
User Name: Manager:
Company:
Test Results
Shot Test: Fault Type R-N
|Z| Phi t nom t act. Dev. VTest Result
16,89 Ω 76,00 ° 1,625 s 1,636 s 0,6523 % 100,0 V Passed
Test State:
Test passed
Distance:
Test Module
Name: OMICRON Distance Version: 3.20
Test Start: 10-Aug-2022 10:55:45 Test End: 10-Aug-2022 10:56:09
User Name: Manager:
Company:
Test Results
Shot Test: Fault Type R-S
|Z| Phi t nom t act. Dev. ITest Result
4,673 Ω 72,00 ° 25,00 ms 44,70 ms 78,8 % 2,000 A Passed
7,500 Ω 72,00 ° 425,0 ms 438,4 ms 3,153 % 2,000 A Passed
16,68 Ω 72,00 ° 1,625 s 1,637 s 0,7446 % 2,000 A Passed
Test State:
Test passed
Distance:
Test Module
Name: OMICRON Distance Version: 3.20
Test Start: 10-Aug-2022 11:11:06 Test End: 10-Aug-2022 11:11:22
User Name: Manager:
Company:
Test Results
Shot Test: Fault Type R-N
|Z| Phi t nom t act. Dev. VTest Result
6,800 Ω 76,00 ° 25,00 ms 44,20 ms 76,8 % 40,00 V Passed
Test State:
Test passed