Product Description

Tube photobioreactor design details

Reference photo

200L glass tube

1000L glass tube 1000L pmma tube

Gas mixer and detection

1
http://www.leadingtec.cn EMAIL:100@leadingtec.cn
1. Device configuration
 Tube:
 Glass tube outer diameter:φ60mm,φ63mm etc.
 PMMA tube diameter :φ90mm,φ110mm,φ160mm etc.
 A glass tube Lenth:2000mm 2800mm 3000mm,PMMA tube Lenth:2000mm 4000mm.
 Customizable capacity.
 Reliable connection between tube and fitting ensure no water leakage.
 LED lighting system:
 Installation is not recommended outdoor
 Indoor:200-3000μE ,or Custom spectrum

 Adjustable light intensity

 Adjustable illumination time


 Runing mode
 Air driver
 Water pump driver
 Support frame:Aluminum profile or detachable stainless steel (Easy to install and
move)

2
http://www.leadingtec.cn EMAIL:100@leadingtec.cn

 Aeration method:Built-in microporous gas stone or hollow fiber membrane


 Control Unit:
 Control cabinet for vacuum pump cycle and valve timing and control.
 Use ABB inverter to control the water pump flow.
 Record the parameters such as PH ,DO, temperature with a recorder.
 Clean tube :the water pump work for the cleaning ball

Control cabinet Gas mixer

Cleaning ball

2. Advantage:
2.1 Glass tube can use strong oxidant cleaning and disinfection,the PMMA can not.
2.2 Adopt pvc and PMMA welding process to ensure no leakage.
2.3 Inlet with UV sterilizing light to reduce system contamination.
2.4 Pvc pipe installation Tee can be connected pH sensors and other sensors.
2.5 PH automatic adjustment :pH sensor with solenoid valve time control, control
the frequency of intake, run-off time period can be achieved, such as open 2 minutes
off 10 seconds, to ensure full mixing and testing time.
2.6 Removable cleaning or semiautomatic cleaning by the cleaning ball.

3
http://www.leadingtec.cn EMAIL:100@leadingtec.cn

3. Basic requirements for the installation site:


3.1 The system uses voltage 380V, 2A, zero wire and ground wire are also needed.
3.2 The scene need tap water and tap water filtration system.
3.3 Room size requirements:length, width and height are specified by customer,
size for reference :1000L glass tube (L*W*H=20m*1m*2.5m),
1000L PMMA tube (L*W*H=9m*1.5m*2.5m)

4
http://www.leadingtec.cn EMAIL:100@leadingtec.cn

Part 2 GAS Mixer And Gas Analyzers(optional)

The Venturi tube are used to mix air and carbon dioxide as required and the

mixed gas carbon dioxide concentration

barometer
Pressure reducing valve

valve Flowmeter

Venturi tube CO2 Detection


CO2

Air pump valve Flowmeter

(1) 1000L (9.5×1.2×2.8,PMMA)GY-Sin-1805,LED(Indoor Use),Temperature

Sensor,pH Sensor,Air-driver+Pump-cleaning,Gas-Mix,

Ex-factory price exclude shipping:120’000 RMB

Ex-factory price exclude shipping:90’000 RMB(Without LED,Outdoor

Use)

(2) 2000L(19*1.2*2.8,PMMA) GY-Sin-1805,LED(Indoor Use),Temperature Sensor,pH

Sensor,Air-driver+Pump-cleaning,Gas-Mix,

Ex-factory price exclude shipping:150’000 RMB

Ex-factory price exclude shipping:120’000 RMB(Without

LED,Outdoor Use)