You are on page 1of 5

USHA INFRAPROJECT PVT. LTD.

702-A Wing, Crown, Vasant Marvel, Western Express Highway, Borivali (E), Mumbai : 400 066.
Mobile : 9870794508,9082304035 www.ushasolarurja.com Udyam registration number
UDYAM-MH-18-0012963
E-mail : ushainfraproject@gmail.com
GST NO:27AABCU3871B1ZI

Quotation For Roof-Top Solar PV Plant (On grid)

To,
Mars4Solutions thane location.
Date-28-08-22

Subject-Proposal For On grid Plant

Dear sir,

With reference to the information provided by you, we would like to present our technical assessment
detailing the technology we propose to use for a Solar Power Plant at your site in.

This proposal explores the Technical Description for Solar Grid Synchronous Power System with Solar Grid
Tie Inverter, Mounting Structures, Civil and Electrical Material Engineering, Procurement.

SUMMARY OF PROPOSAL

Usha Infraproject Pvt Ltd recommends that client uses a Grid Synchronous Solar Power system that will
lower the demand of electricity from the grid and the system will pay for itself over the medium term
by significantly lowering electricity costs. Such a system will feed electricity directly into the building’s
main/LT panel and result in reduction of annual electricity bill. Excess units are exported back to the
grid through net-metering scheme.

1. Supplier: Luminous Mono Perc solar Modules of 540 Wp .


2. Life of system: 25 years generation warranty on solar panels,
3. 5 year warranty on full system

PV SYSTEM SPECIFICATIONS
DC RATING-6 kilowatt

ARRAY TYPE-FIXED TILT

DAILY PRODUCTION (KWH): 24-30 KWH (1 KWH IS 1 UNIT)

ANNUAL PRODUCTION: 7200-15000 KWH (1 KWH IS 1 UNIT we take 300 days for generation year)

AREA REQUIRED-600 SQFT south facing shadow free

Zero your bill with SOLAR


USHA INFRAPROJECT PVT. LTD.
702-A Wing, Crown, Vasant Marvel, Western Express Highway, Borivali (E), Mumbai : 400 066.
Mobile : 9870794508,9082304035 www.ushasolarurja.com Udyam registration number
UDYAM-MH-18-0012963
E-mail : ushainfraproject@gmail.com
GST NO:27AABCU3871B1ZI

RECOMMENDED SYSTEM TYPE


Bill reductions and saves on diesel consumption. Through this system the facility will be able to make
the most of “Net Metering” policy , where the customer can export extra units back to the Grid and avail
usable credits. This can be beneficial during Sundays and vacations when consumption is minimal.
ON GRID-SOLAR SYSTEM
This is the best option where the energy consumption during the day time is large, when the sun is out.
Elimination of battery backup reduces initial costs and maintenance issues. For a location where net
metering is in force, this option is ideal as it would help the building in reducing electricity bills.
WORKING PRINCIPLE
The solar modules when exposed to sunlight generate DC electricity.
Solar Grid Tied Inverter performs the conversion of the variable DC output of the PV modules into a clean
sinusoidal AC power
This inverter needs a synchronizing power which will be either the Grid or DG
The Solar Current will be given lead angle in synchronization process and it will be forcefully injected
into the bus bar
The Loads will be supplied with Solar Power as a prime source of energy and Grid and DG power will
supply remaining part of requirement
SYNCHRONIZATION
The inverter measures the grid (voltage, frequency, phasing) and uses this information to synchronize
the internal regulation. It means the inverter starts up with an open grid contactor and with a grid
independent frequency. Then the controller changes the internal frequency, voltage and phasing so long
as this is absolutely identical to the given values from the grid. Now the electronics will close a soft start
contactor to pre magnetize the internal transformer. Few parts of a second later the main grid contactor
will close and the inverter will feed in. If the grid values are changed when the inverter feeds in the grid,
monitoring will detect it and the controller will adjust the internal regulation so that the inverter is
synchronized with the grid all the time.
PROTECTIONS
• DC Side modules will be given DC Dis-connector Switch which will protect the
System
• For all kinds of faults the Solar Inverter will react first and ISOLATE itself from the
system in Microseconds of time
ADVANTAGES
• Simple and Safe system which gives Direct Savings in Electricity Bill
• Efficient, fit and forget system with least losses.
• 25 years of Guaranteed Generation with Payback Period of 4-5 years
• Accelerated Depreciation on the Investment
LIMITATIONS

• No Back up will be given from the system, since solar power directly utilized
• When power goes off (Grid or DG) Inverter will isolate from the system, stop feeding and Solar
Power will go waste
• Normal meters will rotate in the same direction even when is exported to the grid and feed
power will be charged, so load analysis is critical without net metering.

Zero your bill with SOLAR


USHA INFRAPROJECT PVT. LTD.
702-A Wing, Crown, Vasant Marvel, Western Express Highway, Borivali (E), Mumbai : 400 066.
Mobile : 9870794508,9082304035 www.ushasolarurja.com Udyam registration number
UDYAM-MH-18-0012963
E-mail : ushainfraproject@gmail.com
GST NO:27AABCU3871B1ZI

MATERIAL SPECIFICATIONS:

Component/ Brand Specifications/ Features


Solar Panel Peak Capacity: 540 Wp
Luminous Mono PERC SOLAR MODULES 20 year linear material and workmanship warranty
25 year linear output power guarantee
Conforms with IEC 61215:2005, IEC 61730: 2004, TS
62804,61853,UL 1703 Certified
PV Standards
IEC 60068-2-68, ISO 9001:2015,OHSAS 18001:2007
Certified High Efficiency at 16.70%
Easy handling with durable aluminum frame
Tempered glass for impact resistance
Grid Tie Inverter • Grid Synchronous inverter
Luminous Inverter 6Kw • Wall mounted
• 5 year workmanship warranty
• High quality enclosure
• High Efficiency up to 98.9 %
• Wide Voltage Range
• Reactive Power Control (0. 8 lagging ~ 0.8 leading)
• IP-66 protection for outdoor environment
Mounting Structure • Fixed mounting structure
• Galvanized iron and Anodized Aluminum for long
corrosion resistance
• Designed for peak wind loads
• Stainless steel bolts
• Positive anchoring to roof
DC AND AC Cables • At least 4 mm2 for minimum DC losses
Polycab • High quality copper cable
• UV protected with double layer conduit
• AC Cable of 50 sq.mm 4 core armoured cable from
inverter to acdb and acdb to Net meter
• DC Solar Cable with double layer UV
Protection
• Solar DC Cables 4mm copper From PV array
Module to Junction BOX (DCDB) and DCDB
to Inverter

Zero your bill with SOLAR


USHA INFRAPROJECT PVT. LTD.
702-A Wing, Crown, Vasant Marvel, Western Express Highway, Borivali (E), Mumbai : 400 066.
Mobile : 9870794508,9082304035 www.ushasolarurja.com Udyam registration number
UDYAM-MH-18-0012963
E-mail : ushainfraproject@gmail.com
GST NO:27AABCU3871B1ZI

TERMS AND CONDITIONS


1. Rates are inclusive of 18% GST
2. One year Maintenance AMC included in the above cost
3. Scope of work
Complete SPV system- Design of the plant, Installation and Commissioning.
Power feed-in point –Till the AC junction box located inside the premises.
4. Execution period – 15 to 21 days from date of receiving the work order and issuing advance
5. Transportation of the material till the project site is included in the above cost.
6. Quotation is valid for 30 days
7. Payment terms
50 % Advance remaining 50% on Commission

Bill of Material:

Item Make Size


Solar Panel Luminous Monocrystalline modules 540Wp 11 pieces
Inverter 3 phase inverter luminous 6 Kw
ACDB & DCDB As per Standard
DC Cable Polycab 4 sq.mm
AC Cable Polycab 4 core armoured cable – 6
Sq.mm as per site
Net Meter and generation Secure/HPL mseb approves
meter
Mounting structure Galvanised
Installation and commissioning

Zero your bill with SOLAR


USHA INFRAPROJECT PVT. LTD.
702-A Wing, Crown, Vasant Marvel, Western Express Highway, Borivali (E), Mumbai : 400 066.
Mobile : 9870794508,9082304035 www.ushasolarurja.com Udyam registration number
UDYAM-MH-18-0012963
E-mail : ushainfraproject@gmail.com
GST NO:27AABCU3871B1ZI

QUOTATION:

Rs 4,30,000/- (18% GST included)

TYPICAL SCOPE OF WORK:


1. Services for Final Design and Drawings
2. Installation of Roof Mounted PV Support structures
3. Installation of PV panels and electrical connections
4. Installation of inverter and protection systems
5. Project design and management for PV System
6. Supervision of system installation and commissioning
7. All local labor for installation and commissioning
8. Training of customer
9. Provision of service contract/ AMC
10. Liasioning with MSEDCL ELECTRICITY official for the project clearances
Account Details:
Account Name-Usha Infraproject Private Limited
Account Number-01822320001882
Ifsc code-HDFC0000182
HDFC Bank Kandivali east Thakur complex branch

Zero your bill with SOLAR

You might also like