AUGUST 20, 2016

CUSTOMER: ……………………………….

DPR FOR 3KW SOLAR ROOF TOP


POWER PLANT

PRESENTED BY: MIRRA VENTURE TECHNOLOGIES


122/608 Shastri nagar, near deep Gas Agency
Kanpur-208005
Email id: ravi.mirra@gmail.com
Sankalp.mirra@gmail.com
With reference to our discussions we propose to you our turnkey project proposal for setting up this 3KW
Solar PV hybrid Power Plant.

S.N Particulars Rate Cost

1 Solar Panels: 3 KWatt


Supply and Installation of solar PV Crystalline Modules 95 2,85,000 Rs.
Rs/watt
Solario solar
250 Watt X 12 No’s Poly Crystalline Modules

2 3.75 KVA, single phase hybrid solar pcu


Make: Birla Eapro (Mnre Approved)

Solar battery:
150AH/12V X 4 batteries with 3 years warranty
3 Make: Solario

Mirra Venture Technologies EPC (Engineering, Procurement &


Commissioning):
Design, Supply, Installation, Testing and Commissioning of turnkey
4 project:
- Civil and mechanical works
- Balance of System (BOS): junction boxes, earthing kits, AC &
DC cables boxes, Main LT cable, contour pipes etc.
- Galvanized & painted Mounting structures withstanding wind
Speeds up to 120 kmph.
Project Cost INR 2,85,000/-
Tax NIL

Total Project Cost for 3 KW Solar System INR 2,85,000/-


(Inclusive of taxes, duties and transportation)
YEARLY ELECTRICITY GENERATION UNIT 4400 UNIT

DPR FOR 3 KW SOLAR ROOF TOP POWER PLANT


Warranty Terms:

Solar Panel: Performance output warranty- 5years


Solar Inverter: Replacement Warranty - 5 years
System Installation: Mirra Venture Technologies EPC & Workmanship Warranty - 5 years
Other Balance of material: Warranty as by manufacturer and as per approved guidelines.
Other Terms and conditions:
Quotation validity: 30 days
Prices are for SITC (Supply, Installation, Testing and Commissioning) NO HIDDEN OR EXTRA COST
2% interest penalty (per month) shall be charged for overdue amount.
This price includes earthing equipment installation.
Transportation and freight inclusive.

Payment Schedule: 60% Advance


30% at the time of delivery of material.
10% after installation.

Important Facts:

- Estimated Power Generation: 3 KW X 4 to 5 hours/day i.e. approx. 12-15 Kwh/ day


- Space Requirement: 300 sq. ft. shadow free area
- Mounting Tilt: Fixed between 20 to 30 degrees facing South-South-West
- Type of Structure: Design & placement depending on site specifications
- Earthing: Pit shall be constructed if not available at site
considered (no module spares, but inverters spares
- Electrical Equipment spares: considered)
- Weight of Each panel: 19 kilos
- Operation & maintenance: Cleaning of Solar Panels recommended every 7-12 days

Schedule: Completion of project within Ten (10) days from date of Purchase order and Advance.

Team involved for this project:

Project head: Ravi Pandey


Email- ravi.mirra@gmail.com
(7618029029)

Project manager: Sankalp Ojha


Email- sankalp.mirra@gmail.com
(7618002121)

Project Engineer: Anoop yadav


Site Supervisor: Gaurav tiwari
Ashok sharma

DPR FOR 3 KW SOLAR ROOF TOP POWER PLANT


SOLAR PV MODULES:

Solar cells produce direct current (DC) electricity using light, which can be used to power
equipment or to recharge a battery. Cells require protection from the environment and are
usually packaged tightly in-between a glass sheet and a Tedlar based back sheet. When more
power is required than a single cell can deliver, cells are electrically connected together to form
photovoltaic modules, or solar panels. A photovoltaic module is a package inter connected
assembly of photovoltaic cells, which converts sunlight in to electrical power. The cells are
hermitically sealed between glass and back sheet (Tedlar) to protect them from harsh
environments.

The detail technical specifications of solar modules are provided below.

Characteristic Value
Maximum Power 250Wp
Open-Circuit Voltage (Voc) 37.1 V
Maximum Power Voltage 30.2V
Short-Circuit Current (Isc) 8.7 A
Maximum Power Current
(Imp) 8.28 A
Efficiency >15%
Power Tolerance ±3%
Temperature coefficient -0.44%/Kelvin
Temperature coefficient of Voc -2.13 mV/Kelvin
Temperature coefficient of Isc 4.46 mA/Kelvin
Operating Temperature 47+ 2

DPR FOR 3 KW SOLAR ROOF TOP POWER PLANT


General Mechanical Parameters of Solar Panel:
- Cell type 72 no's Poly-crystalline solar cells (156mm*156mm);
- Glass High Transmission Low Iron Tempered Glass
- Frame Anodized aluminum frame with twin wall profile
- Junction Box IP65, 3 Bypass Diodes
- Dimension 1650×992×45mm
- Weight 19 KG
- Cable Length 4mm², 900 mm, Solarlok/MC4 Compatible Connectors)

Certifications: ISO 9001:3008, ISO14001:3004, OHSAS18001 certified factory IEC61215, IEC61730, IEC
61701, IEC 61215, MCS Certified and UL 1703 for USA & CEC certified products.

Warranty: 10 year warranty on material & workmanship, Premium linear performance


warranty.
Industry leading power output warranty (12 years/ 90%, 25years/ 80%) 25 Year
performance warranty.

DPR FOR 3 KW SOLAR ROOF TOP POWER PLANT


SOLAR HYBRID INVERTER:

The RPI is a high-quality String inverter which is used to supply photovoltaically converted solar
energy from PV modules to low-voltage networks. The string inverter converts the direct current
generated in PV cells into alternating current. This enables you to feed the solar electricity which you
have generated into the public electricity grid of the utility company. The efficient MPP tracking
system ensures that the PV plant operates sat maximum efficiency, even on dull days when the sky
is cloudy.

With the MPPT concept, PV modules connected in series (strings) or strings at the same voltage
connected in parallel area always connected to the string inverter so that the amount of wiring in the
photovoltaic plant issue abstantially reduced. The photovoltaic plant can also be optimized to the
input voltage range of the string inverter by the interconnection in the strings. The modules are
design of the string inverter take sin to account the market requirements for flexible inverter
solutions with higher output ranges.

3 KW | 48V | Single phase | Solar + Grid + Battery

BATTERY BANK:
Battery Make Type Description of Items Warranty
Solario Tubular Batteries 150AH/12V X 4nos. 3 yrs.

DPR FOR 3 KW SOLAR ROOF TOP POWER PLANT


Cable and wire:

We integrate all the small and large equipment’s required for the commissioning of the solar power plant. All
equipment’s including cablings and the installation methodology are followed as per the installation guidelines
and manual by the Panel manufactures. The other equipment’s are IEC and TUV certified.

Earthing pits AC & DC Cables Combiner Boxes/ACDB Array Junction Boxes

Cables and Connectors, Junction Boxes:

The cables deployed will be robust and resist high mechanical load and tension. High temperature resistance
and weather proofing characteristics will provide long life. The connectors will have high current carrying
capacity.

EARTHING AND LIGHTENING PROTECTION:

Earthing: The array structure of the PV yard will be grounded properly using adequate number of
earthing kits. All metal casing /shield in got the plant shall be thoroughly grounded to ensure safety of
the power plant.

Lightning Protection: The SPV Power Plant will be provided with lightning & overvoltage protection. The
main aim in this protection shall be to reduce the over voltage to a tolerable value before it reaches the
PV or other sub system components. The source of over voltage can be lightning, atmosphere
disturbances etc. Metal oxide varistor shall be provided inside the Array Junction Boxes. In addition
suitable MOV’s also shall be provided in the Inverter to protect the inverter from overvoltage.

Electrical:
Fire-proof hose shaft will be used for running electrical cables down to the electrical panel room.

Metering:
PV Array Energy Production: Digital Meters shall log the actual value of AC/DC Voltage, Current & Energy
generated by the PV system shall be provided.

DPR FOR 3 KW SOLAR ROOF TOP POWER PLANT


RU
STRUCTURE:

Mounting Structure options of Hot Dip GI, Aluminum rails for sheds or Fiber Glass.

Design Type: General Installation on Flat Roof tops

The frames and leg assemblies of the array structures are made after sections of angle, channel or any other
section confirming to IS 3062. Hot dip galvanized steel nuts and bolts will be used to fix the structures. The
structure is designed in such a way that it will occupy minimum space without sacrificing the output from
Solar panels.

THANK YOU