GENERAL NOTES

NOTE 1: REPRODUCTION OF THE BUILDER'S DRAWING IS DONE BY THE ORDER OF THE VESSEL'S OWNER
AND FOR THE PURPOSE OF THIS PROJECT ONLY. THIS DRAWING IS REPRODUCTION OF THE BUILDER'S
DRAWINGS:
-1057DA800D101 "P/D OF BALLAST SYSTEM"
-1057DA800D101 "P/D OF FIRE AND DECK WASH SYSTEM".

NOTE 2: BOLD LINES INDICATE NEW / ADDITIONAL LINES / ITEMS.

NOTE 3: ERMA FIRST SCOPE OF SUPPLY.

PRELIMINARY
REV. No. DATE DESCRIPTION DRAWN APPROVED

Title:

BALLAST SYSTEM DIAGRAM

Drawn by: Project :


A.LEŠTANIN W-ORIGINAL
Checked by: (IMO NO.9627758)
N.TODOSIJEVIĆ
Approved by: Date: Drawing Number: Class: LR Sheet size: A4
D.DOXARAS 04/03/2022 21468-P-PD-01 Scale: N/A Sheet No.: 1/192/3

118B, Agias Eleousis Str., Marousi, 151 25, Athens, ©Copyright


Greece Tel.: +302108056220 Fax: +302108056221 All drawings are property of ARGO NAVIS ENGINEERS LTD. and they
E-mail:mail@argonavis.gr Website:www.argonavis.gr must not be partially or wholly copied or used without the written permission
of ARGO NAVIS ENGINEERS LTD.
8 7 6 5 4 3 2 1
LEGEND:

PRELIMINARY
DENOTES EXISTING LINE
DENOTES NEW LINE
STATIONARY BA111-JASBL-350A Note : 1. * marked valves (4EA) to have a throttling function.
2. ! marked items to be supplied by the pump maker. TP TIE-IN POINT
HAND PUMP
BA120 3. # marked items to be supplied by the V.R.C system maker.

H
F (10K-350A) 4. F : Full Flooding SEE TYPICAL ''A" F
5. P.F : Partial Flooding
TP BA603-
11 JASBL-400A

MBL-11 DN350
DN50 MAIN DECK
TO TROS

BA216 BA217
DN50

(10K)
VOID (P) BA604-
FROM BIS
DN50 JACAX-400A
TO TROS NO.4
NO.6 NO.5 NO.3 W.B.TK. NO.2 W.B.TK. NO.1 W.B.TK.
DN50 W.B.TK.(P)
TO G2S H.F.O.TK.(P) H.F.O.TK.(P) (P) (P) (P)
TP
10

BA406-JAFAX-250A

BA404-JAFAX-250A

BA402-JAFAX-250A
ENGINE ROOM
NO.6 NO.4 NO.2
TP NO.7 NO.5 NO.5 NO.1
C/H C/H C/H
04 BA126 BA122 C/H C/H C/H C/H
(P.F) (F) (P.F)
BA125 BA121
BA118 PI B.S.E CP

H BA113
BA116-JABAX-250A

BA214-JACAX-
BA216-JACAX-

BA212-JACAX-
A.P.TK BALLAST WELL WITH COVER
(5K-300A) A

BA218-JACAX-
BAxxx-JACAX-xxxA
(TYPICAL)

PI

BA115-JABAX-250A
BA118-JABAX-300A

BA120-JACAX-

BA210-JACAX-
E E

300A
300A

300A
SEE NOTE (TYP.)
TP

BA123
BA124

BA114-JABAX-400A
350x400

350A
BA117-JABAX- 07

350A
250A
MBL-01

TP BA113-JABAX-350A

300A
06

(250A)
BA112

BA111

(250A)
BA208-JACAX- BA206-JACAX-

(250A)

H
BA110

BA117
* * * * NO.6 300A 300A

BA219
BA204-JACAX-300A

* H
BA108-JABAX-350A

H
PT PI CP PT

BA102

BA211

BA209

BA207

BA213

BA205

BA203
* PI
! ! CP * W.B.TK. (P)
BA201

S.W.CROSS MAIN IN E/R


BA108 BA104

H
H

H
BA116-JABAX-250A

H
* H BA115 ! ! H H

BA203-

(SEE .DA700M001)
BA106- BA102-JABAX-400A
(350A) NO.5 BA202-JACAX-400A Sliding type Expansion Coupling (FCD/NBR) JACAX-300A
JABAX-350A NO.2 W.B.P/P BA104-
H
W.B.TK. (P) Quantity and location will be defined in detail design stage.
TP (1200m3/h x 25m) JABAX-400A

(250A)
BA116

BA127
DN350

03 H BA106 F.P.TK

H
* PT * PI CP * PT *
* PI
! ! CP * BA101-JABAX-400A BA201-JACAX-400A
BA107 BA105- BA103
* H BA114 ! ! H
JABAX-350A

BA210

BA208

BA206

BA212

BA203
BA101

BA218

BA204

H
H

H
H

H
(350A) NO.6 NO.5 BA207-JACAX- BA205-JACAX-
H W.B.TK. (S) W.B.TK. (S)
MBL-01

NO.1 W.B.P/P BA103- 300A 300A


BA109

TP

BA209-JACAX-
BA119-JACAX-
(1200m3/h x 25m) JABAX-400A
BA109-JABAX-350A

H *

01
D BA105
BA217-JACAX- D

350A
BA213-JACAX-

BA211-JACAX-
BA215-JACAX-
BA112-JABAX-350A
TP 350A
02

300A

300A

300A
300A
350x400

TP
350x400

05
LS SACRIFICE FLANGE
A.P.TK
A

BA403-JAFAX-250A

BA401-JAFAX-250A
BA405-JAFAX-250A
V1-01
NOTE 3 NO.6 NO.4 NO.2
NO.5 NO.1
BWN03

NO.7 NO.3 C/H


C/H C/H C/H C/H
TP C/H C/H (P.F)
(P.F) (F)
08
MBL-10 DN350

DN50
TO TROS

BA215 BA214
DN50 NO.4 W.B.TK. CORRESPONDING
NO.6 NO.5
FROM BIS (S) NO.3 W.B.TK. NO.2 W.B.TK. PIPE (250A)
DN50 H.F.O.TK.(S) H.F.O.TK.(S) NO.1 W.B.TK.
TO TROS BA602 (S) (S) (S)

(10K)
DN50 JACAX-400A
TO G2S VOID (S)

C STATIONARY BA601 ON MAIN DECK C


HAND PUMP JASBL-400A CORRESPONDING CORRESPONDING
TP
DN400

DN50 PIPE (250A) TRUNK


09 FROM TROR IN W.B.TK
(TYPICAL)
DN50
FROM TROR
H

BA119 MBL-09 DN150


C (Next Page)
(10K-350A) TYPICAL SECTION
BWN13 BWN14
BA110
MBL-03

WATER BALLAST OVERBOARD -JASBL TYPICAL ''A''


-350A NOTE 3
BELOW LIGHT BALLAST WATER LINE

15
V1-03
LS STPG370 SMLS
BWN01

LS
16.0T (400A)
FM-1-A ELECTROLYTIC CELL
DN50
DN100

350x400 350x400 V3-02 (C-1-A)


NOTE 3 NOTE 3 V3-01 MAIN DECK
S
MBL-01

NOTE 3 NOTE 3
ABT.1.3M
PRV-1-A
TO TROS

DN400
Spool for future NOTE 3
installation of (10K 400A)

ABT 2MM
W.B.TK(P) W.B.TK(S)
SMD-1-A
Vacuum Relief Valve NO.4 C/H OVERFLOW PIPE
NOTE 3
B DN15 B
DN80
FROM DRAIN TANK STPG370 ERW 12.7T(400A)

SIDE SHELL
MBL-02
INSIDE

SLEEVE
WELDING
MBL-08 DN150 INTER-CONNECTION PIPE CARGO HOLD
B (Next Page) STPG370 SMLS 16.0T(250A)
NOTE 3
BWN10 BWN11 BWN12 ARRANGED IN C/HOLD
SET TO 5bar SLEEVE JOIN
MBL-01 DN400 FILTER
F-1-A
V1-02 BWN02
NOTE 3
SWP1 LOWER STOOL
NOTE 3
V5-01-A

MBL-06 MBL-07 H H
D (Next Page)
DN65 DN65
BWN07 65x50 65X32 BWN08 V6-01 BWN09
NOTE 3 NOTE 3
MBL-04
DN80

400A 400A
SP-1-A W.B.TK(P) W.B.TK(S)
MBL-05
DN80
BWN06 BWN05 80x40 80x65 BWN04
NOTE 3
A A
SHEET No. PAPER SIZE
BALLAST SYSTEM DIAGRAM
2/19 A2
DATE REV. No. DRAWING No. SCALE
04/03/2022 -- 21468-P-PD-01 N/A

8 7 6 5 4 3 2 1
6 5 4 3 2 1
LEGEND:

PRELIMINARY
DENOTES EXISTING LINE
DENOTES NEW LINE

TP TIE-IN POINT

(125A)
WDE16
D IN ENGINE D
CASING UPPER DECK
WD032-JABBX-50A

WDE15

WD091-JABBX-80A
ENGINE WD132-JABBX-50A
WDE14
ROOM WD036-JABBX-50A 1ST P.F DECK
WDE13
WD014 WD035-JABBX-50A
HOLD BILGE
EDUCTOR WDE12
WD033-JABBX-50A 2ND P.F DECK
BSE06
S/G RM. (65A) WDE17 WDE11
(80A)
WD130-JABBX-50A
TP TP
C WDE10 C
WD107 WD106 N.C. 15 14
BG203 WD039-JABBX-125A WD131-JABBX-50A FLOOR
TO BILGE OVBD H MBL-12 DN250 (250A)
WD015

BG104-JACBX-250A
OIL COOLER DA700M001-23

DN50
DN50
DN50
DN50
FOR DK MACH. 10K
(10K-200A)
L.O
WDE09 BG102 WDE07 WDE08 BG101 WDE06

WD045-JABBX-200A
TO TROS
E/R

TO TROS
TO G2S

FROM BIS
* PT * PI
PI * PT *
* PI
! *
! PI

! !
NO.2 BILGE, FIRE & NO.1
* PT * CP
G/S PUMPs CP * PT *
D (Previous Page)

* CP
! (90/250 M3/H ! CP *
C (Previous Page)

! X 75/25 mTH) !
B B
B (Previous Page)
SACRIFACE FLANGE

BG045 BG044
(250A) (250A) (250A) (250A)
MBL-06

(10K,200A)

(10K,200A)
DN65

WDE02
WDE03

BG042
BG043
WDE05

WDE04

N.C
N.C
MBL-08
DN150

TP
MBL-09

L.O
DN150

(5K,200A)
13

(5K,200A)
SEE PAGE 10/29

WD030-JABBX-200A FROM CARGO HOLD BILGE MAIN LINE


WDE01
(150A)

BWN15
S.W.CROSS MAIN IN E/R
TP
A.P.TK 12

A A
SHEET No. PAPER SIZE
BALLAST SYSTEM DIAGRAM
3/19 A3
DATE REV. No. DRAWING No. SCALE
04/03/2022 -- 21468-P-PD-01 N/A

6 5 4 3 2 1
8 7 6 5 4 3 2 1
LEGEND:

PRELIMINARY
DENOTES EXISTING LINE
DENOTES NEW LINE
STATIONARY BA111-JASBL-350A Note : 1. * marked valves (4EA) to have a throttling function. DENOTES FLUID FLOW
HAND PUMP 2. ! marked items to be supplied by the pump maker.
BA120 3. # marked items to be supplied by the V.R.C system maker. TP TIE-IN POINT

H
F (10K-350A) 4. F : Full Flooding SEE TYPICAL ''A" F
5. P.F : Partial Flooding
TP BA603-
11 JASBL-400A

MBL-11 DN350
DN50 MAIN DECK
TO TROS

BA216 BA217
DN50

(10K)
VOID (P) BA604-
FROM BIS
DN50 JACAX-400A
TO TROS NO.4
NO.6 NO.5 NO.3 W.B.TK. NO.2 W.B.TK. NO.1 W.B.TK.
DN50 W.B.TK.(P)
TO G2S H.F.O.TK.(P) H.F.O.TK.(P) (P) (P) (P)
TP
10

BA406-JAFAX-250A

BA404-JAFAX-250A

BA402-JAFAX-250A
ENGINE ROOM
NO.6 NO.4 NO.2
TP NO.7 NO.5 NO.5 NO.1
C/H C/H C/H
04 BA126 BA122 C/H C/H C/H C/H
(P.F) (F) (P.F)
BA125 BA121
BA118 PI B.S.E CP

H BA113
BA116-JABAX-250A

BA214-JACAX-
BA216-JACAX-

BA212-JACAX-
A.P.TK BALLAST WELL WITH COVER
(5K-300A) A

BA218-JACAX-
BAxxx-JACAX-xxxA
(TYPICAL)

PI

BA115-JABAX-250A
BA118-JABAX-300A

BA120-JACAX-

BA210-JACAX-
E E

300A
300A

300A
SEE NOTE (TYP.)
TP

BA123
BA124

BA114-JABAX-400A
350x400

350A
BA117-JABAX- 07

350A
250A
MBL-01

TP BA113-JABAX-350A

300A
06

(250A)
BA112

BA111

(250A)
BA208-JACAX- BA206-JACAX-

(250A)

H
BA110

BA117
* * * * NO.6 300A 300A

BA219
BA204-JACAX-300A

* H
BA108-JABAX-350A

H
PT PI CP PT

BA102

BA211

BA209

BA207

BA213

BA205

BA203
* PI
! ! CP * W.B.TK. (P)
BA201

S.W.CROSS MAIN IN E/R


BA108 BA104

H
H

H
BA116-JABAX-250A

H
* H BA115 ! ! H H

BA203-

(SEE .DA700M001)
BA106- BA102-JABAX-400A
(350A) NO.5 BA202-JACAX-400A Sliding type Expansion Coupling (FCD/NBR) JACAX-300A
JABAX-350A NO.2 W.B.P/P BA104-
H
W.B.TK. (P) Quantity and location will be defined in detail design stage.
TP (1200m3/h x 25m) JABAX-400A

(250A)
BA116

BA127
DN350

03 H BA106 F.P.TK

H
* PT * PI CP * PT *
* PI
! ! CP * BA101-JABAX-400A BA201-JACAX-400A
BA107 BA105- BA103
* H BA114 ! ! H
JABAX-350A

BA210

BA208

BA206

BA212

BA203
BA101

BA218

BA204

H
H

H
H

H
(350A) NO.6 NO.5 BA207-JACAX- BA205-JACAX-
H W.B.TK. (S) W.B.TK. (S)
MBL-01

NO.1 W.B.P/P BA103- 300A 300A


BA109

TP

BA209-JACAX-
BA119-JACAX-
(1200m3/h x 25m) JABAX-400A
BA109-JABAX-350A

H *

01
D BA105
BA217-JACAX- D

350A
BA213-JACAX-

BA211-JACAX-
BA215-JACAX-
BA112-JABAX-350A
TP 350A
02

300A

300A

300A
300A
350x400

TP
350x400

05
LS SACRIFICE FLANGE
A.P.TK
A

BA403-JAFAX-250A

BA401-JAFAX-250A
BA405-JAFAX-250A
V1-01
NOTE 3 NO.6 NO.4 NO.2
NO.5 NO.1
BWN03

NO.7 NO.3 C/H


C/H C/H C/H C/H
TP C/H C/H (P.F)
(P.F) (F)
08
MBL-10 DN350

DN50
TO TROS

BA215 BA214
DN50 NO.4 W.B.TK. CORRESPONDING
NO.6 NO.5
FROM BIS (S) NO.3 W.B.TK. NO.2 W.B.TK. PIPE (250A)
DN50 H.F.O.TK.(S) H.F.O.TK.(S) NO.1 W.B.TK.
TO TROS BA602 (S) (S) (S)

(10K)
DN50 JACAX-400A
TO G2S VOID (S)

C STATIONARY BA601 ON MAIN DECK C


HAND PUMP JASBL-400A CORRESPONDING CORRESPONDING
TP
DN400

DN50 PIPE (250A) TRUNK


09 FROM TROR IN W.B.TK
(TYPICAL)
DN50
FROM TROR
H

BA119 MBL-09 DN150


C (Next Page)
(10K-350A) TYPICAL SECTION
BWN13 BWN14
BA110
MBL-03

WATER BALLAST OVERBOARD -JASBL TYPICAL ''A''


-350A NOTE 3
BELOW LIGHT BALLAST WATER LINE

15
V1-03
LS STPG370 SMLS
BWN01

LS
16.0T (400A)
FM-1-A ELECTROLYTIC CELL
DN50
DN100

350x400 350x400 V3-02 (C-1-A)


NOTE 3 NOTE 3 V3-01 MAIN DECK
S
MBL-01

NOTE 3 NOTE 3
ABT.1.3M
PRV-1-A
TO TROS

DN400
Spool for future NOTE 3
installation of (10K 400A)

ABT 2MM
W.B.TK(P) W.B.TK(S)
SMD-1-A
Vacuum Relief Valve NO.4 C/H OVERFLOW PIPE
NOTE 3
B DN15 B
DN80
FROM DRAIN TANK STPG370 ERW 12.7T(400A)

SIDE SHELL
MBL-02
INSIDE

SLEEVE
WELDING
MBL-08 DN150 INTER-CONNECTION PIPE CARGO HOLD
B (Next Page) STPG370 SMLS 16.0T(250A)
NOTE 3
BWN10 BWN11 BWN12 ARRANGED IN C/HOLD
SET TO 5bar SLEEVE JOIN
MBL-01 DN400 FILTER
F-1-A
V1-02 BWN02
NOTE 3
SWP1 LOWER STOOL
NOTE 3
V5-01-A

MBL-06 MBL-07 H H
D (Next Page)
DN65 DN65
BWN07 65x50 65X32 BWN08 V6-01 BWN09
NOTE 3 NOTE 3
MBL-04
DN80

400A 400A
SP-1-A W.B.TK(P) W.B.TK(S)
MBL-05
DN80
BWN06 BWN05 80x40 80x65 BWN04
NOTE 3
A A
SHEET No. PAPER SIZE
BALLASTING WITH No.1 BALLAST PUMP
4/19 A2
DATE REV. No. DRAWING No. SCALE
04/03/2022 -- 21468-P-PD-01 N/A

8 7 6 5 4 3 2 1
6 5 4 3 2 1
LEGEND:

PRELIMINARY
DENOTES EXISTING LINE
DENOTES NEW LINE

TP TIE-IN POINT

(125A)
WDE16
D IN ENGINE D
CASING UPPER DECK
WD032-JABBX-50A

WDE15

WD091-JABBX-80A
ENGINE WD132-JABBX-50A
WDE14
ROOM WD036-JABBX-50A 1ST P.F DECK
WDE13
WD014 WD035-JABBX-50A
HOLD BILGE
EDUCTOR WDE12
WD033-JABBX-50A 2ND P.F DECK
BSE06
S/G RM. (65A) WDE17 WDE11
(80A)
WD130-JABBX-50A
TP TP
C WDE10 C
WD107 WD106 N.C. 15 14
BG203 WD039-JABBX-125A WD131-JABBX-50A FLOOR
TO BILGE OVBD H MBL-12 DN250 (250A)
WD015

BG104-JACBX-250A
OIL COOLER DA700M001-23

DN50
DN50
DN50
DN50
FOR DK MACH. 10K
(10K-200A)
L.O
WDE09 BG102 WDE07 WDE08 BG101 WDE06

WD045-JABBX-200A
TO TROS
E/R

TO TROS
TO G2S

FROM BIS
* PT * PI
PI * PT *
* PI
! *
! PI

! !
NO.2 BILGE, FIRE & NO.1
* PT * CP
G/S PUMPs CP * PT *
D (Previous Page)

* CP
! (90/250 M3/H ! CP *
C (Previous Page)

! X 75/25 mTH) !
B B
B (Previous Page)
SACRIFACE FLANGE

BG045 BG044
(250A) (250A) (250A) (250A)
MBL-06

(10K,200A)

(10K,200A)
DN65

WDE02
WDE03

BG042
BG043
WDE05

WDE04

N.C
N.C
MBL-08
DN150

TP
MBL-09

L.O
DN150

(5K,200A)
13

(5K,200A)
SEE PAGE 10/29

WD030-JABBX-200A FROM CARGO HOLD BILGE MAIN LINE


WDE01
(150A)

BWN15
S.W.CROSS MAIN IN E/R
TP
A.P.TK 12

A A
SHEET No. PAPER SIZE
BALLASTING WITH No.1 BALLAST PUMP
5/19 A3
DATE REV. No. DRAWING No. SCALE
04/03/2022 -- 21468-P-PD-01 N/A

6 5 4 3 2 1
8 7 6 5 4 3 2 1
LEGEND:

PRELIMINARY
DENOTES EXISTING LINE
DENOTES NEW LINE
STATIONARY BA111-JASBL-350A Note : 1. * marked valves (4EA) to have a throttling function. DENOTES FLUID FLOW
HAND PUMP 2. ! marked items to be supplied by the pump maker.
BA120 3. # marked items to be supplied by the V.R.C system maker. TP TIE-IN POINT

H
F (10K-350A) 4. F : Full Flooding SEE TYPICAL ''A" F
5. P.F : Partial Flooding
TP BA603-
11 JASBL-400A

MBL-11 DN350
DN50 MAIN DECK
TO TROS

BA216 BA217
DN50

(10K)
VOID (P) BA604-
FROM BIS
DN50 JACAX-400A
TO TROS NO.4
NO.6 NO.5 NO.3 W.B.TK. NO.2 W.B.TK. NO.1 W.B.TK.
DN50 W.B.TK.(P)
TO G2S H.F.O.TK.(P) H.F.O.TK.(P) (P) (P) (P)
TP
10

BA406-JAFAX-250A

BA404-JAFAX-250A

BA402-JAFAX-250A
ENGINE ROOM
NO.6 NO.4 NO.2
TP NO.7 NO.5 NO.5 NO.1
C/H C/H C/H
04 BA126 BA122 C/H C/H C/H C/H
(P.F) (F) (P.F)
BA125 BA121
BA118 PI B.S.E CP

H BA113
BA116-JABAX-250A

BA214-JACAX-
BA216-JACAX-

BA212-JACAX-
A.P.TK BALLAST WELL WITH COVER
(5K-300A) A

BA218-JACAX-
BAxxx-JACAX-xxxA
(TYPICAL)

PI

BA115-JABAX-250A
BA118-JABAX-300A

BA120-JACAX-

BA210-JACAX-
E E

300A
300A

300A
SEE NOTE (TYP.)
TP

BA123
BA124

BA114-JABAX-400A
350x400

350A
BA117-JABAX- 07

350A
250A
MBL-01

TP BA113-JABAX-350A

300A
06

(250A)
BA112

BA111

(250A)
BA208-JACAX- BA206-JACAX-

(250A)

H
BA110

BA117
* * * * NO.6 300A 300A

BA219
BA204-JACAX-300A

* H
BA108-JABAX-350A

H
PT PI CP PT

BA102

BA211

BA209

BA207

BA213

BA205

BA203
* PI
! ! CP * W.B.TK. (P)
BA201

S.W.CROSS MAIN IN E/R


BA108 BA104

H
H

H
BA116-JABAX-250A

H
* H BA115 ! ! H H

BA203-

(SEE .DA700M001)
BA106- BA102-JABAX-400A
(350A) NO.5 BA202-JACAX-400A Sliding type Expansion Coupling (FCD/NBR) JACAX-300A
JABAX-350A NO.2 W.B.P/P BA104-
H
W.B.TK. (P) Quantity and location will be defined in detail design stage.
TP (1200m3/h x 25m) JABAX-400A

(250A)
BA116

BA127
DN350

03 H BA106 F.P.TK

H
* PT * PI CP * PT *
* PI
! ! CP * BA101-JABAX-400A BA201-JACAX-400A
BA107 BA105- BA103
* H BA114 ! ! H
JABAX-350A

BA210

BA208

BA206

BA212

BA203
BA101

BA218

BA204

H
H

H
H

H
(350A) NO.6 NO.5 BA207-JACAX- BA205-JACAX-
H W.B.TK. (S) W.B.TK. (S)
MBL-01

NO.1 W.B.P/P BA103- 300A 300A


BA109

TP

BA209-JACAX-
BA119-JACAX-
(1200m3/h x 25m) JABAX-400A
BA109-JABAX-350A

H *

01
D BA105
BA217-JACAX- D

350A
BA213-JACAX-

BA211-JACAX-
BA215-JACAX-
BA112-JABAX-350A
TP 350A
02

300A

300A

300A
300A
350x400

TP
350x400

05
LS SACRIFICE FLANGE
A.P.TK
A

BA403-JAFAX-250A

BA401-JAFAX-250A
BA405-JAFAX-250A
V1-01
NOTE 3 NO.6 NO.4 NO.2
NO.5 NO.1
BWN03

NO.7 NO.3 C/H


C/H C/H C/H C/H
TP C/H C/H (P.F)
(P.F) (F)
08
MBL-10 DN350

DN50
TO TROS

BA215 BA214
DN50 NO.4 W.B.TK. CORRESPONDING
NO.6 NO.5
FROM BIS (S) NO.3 W.B.TK. NO.2 W.B.TK. PIPE (250A)
DN50 H.F.O.TK.(S) H.F.O.TK.(S) NO.1 W.B.TK.
TO TROS BA602 (S) (S) (S)

(10K)
DN50 JACAX-400A
TO G2S VOID (S)

C STATIONARY BA601 ON MAIN DECK C


HAND PUMP JASBL-400A CORRESPONDING CORRESPONDING
TP
DN400

DN50 PIPE (250A) TRUNK


09 FROM TROR IN W.B.TK
(TYPICAL)
DN50
FROM TROR
H

BA119 MBL-09 DN150


C (Next Page)
(10K-350A) TYPICAL SECTION
BWN13 BWN14
BA110
MBL-03

WATER BALLAST OVERBOARD -JASBL TYPICAL ''A''


-350A NOTE 3
BELOW LIGHT BALLAST WATER LINE

15
V1-03
LS STPG370 SMLS
BWN01

LS
16.0T (400A)
FM-1-A ELECTROLYTIC CELL
DN50
DN100

350x400 350x400 V3-02 (C-1-A)


NOTE 3 NOTE 3 V3-01 MAIN DECK
S
MBL-01

NOTE 3 NOTE 3
ABT.1.3M
PRV-1-A
TO TROS

DN400
Spool for future NOTE 3
installation of (10K 400A)

ABT 2MM
W.B.TK(P) W.B.TK(S)
SMD-1-A
Vacuum Relief Valve NO.4 C/H OVERFLOW PIPE
NOTE 3
B DN15 B
DN80
FROM DRAIN TANK STPG370 ERW 12.7T(400A)

SIDE SHELL
MBL-02
INSIDE

SLEEVE
WELDING
MBL-08 DN150 INTER-CONNECTION PIPE CARGO HOLD
B (Next Page) STPG370 SMLS 16.0T(250A)
NOTE 3
BWN10 BWN11 BWN12 ARRANGED IN C/HOLD
SET TO 5bar SLEEVE JOIN
MBL-01 DN400 FILTER
F-1-A
V1-02 BWN02
NOTE 3
SWP1 LOWER STOOL
NOTE 3
V5-01-A

MBL-06 MBL-07 H H
D (Next Page)
DN65 DN65
BWN07 65x50 65X32 BWN08 V6-01 BWN09
NOTE 3 NOTE 3
MBL-04
DN80

400A 400A
SP-1-A W.B.TK(P) W.B.TK(S)
MBL-05
DN80
BWN06 BWN05 80x40 80x65 BWN04
NOTE 3
A A
SHEET No. PAPER SIZE
BALLASTING WITH No.2 BALLAST PUMP
6/19 A2
DATE REV. No. DRAWING No. SCALE
04/03/2022 -- 21468-P-PD-01 N/A

8 7 6 5 4 3 2 1
6 5 4 3 2 1
LEGEND:

PRELIMINARY
DENOTES EXISTING LINE
DENOTES NEW LINE

TP TIE-IN POINT

(125A)
WDE16
D IN ENGINE D
CASING UPPER DECK
WD032-JABBX-50A

WDE15

WD091-JABBX-80A
ENGINE WD132-JABBX-50A
WDE14
ROOM WD036-JABBX-50A 1ST P.F DECK
WDE13
WD014 WD035-JABBX-50A
HOLD BILGE
EDUCTOR WDE12
WD033-JABBX-50A 2ND P.F DECK
BSE06
S/G RM. (65A) WDE17 WDE11
(80A)
WD130-JABBX-50A
TP TP
C WDE10 C
WD107 WD106 N.C. 15 14
BG203 WD039-JABBX-125A WD131-JABBX-50A FLOOR
TO BILGE OVBD H MBL-12 DN250 (250A)
WD015

BG104-JACBX-250A
OIL COOLER DA700M001-23

DN50
DN50
DN50
DN50
FOR DK MACH. 10K
(10K-200A)
L.O
WDE09 BG102 WDE07 WDE08 BG101 WDE06

WD045-JABBX-200A
TO TROS
E/R

TO TROS
TO G2S

FROM BIS
* PT * PI
PI * PT *
* PI
! *
! PI

! !
NO.2 BILGE, FIRE & NO.1
* PT * CP
G/S PUMPs CP * PT *
D (Previous Page)

* CP
! (90/250 M3/H ! CP *
C (Previous Page)

! X 75/25 mTH) !
B B
B (Previous Page)
SACRIFACE FLANGE

BG045 BG044
(250A) (250A) (250A) (250A)
MBL-06

(10K,200A)

(10K,200A)
DN65

WDE02
WDE03

BG042
BG043
WDE05

WDE04

N.C
N.C
MBL-08
DN150

TP
MBL-09

L.O
DN150

(5K,200A)
13

(5K,200A)
SEE PAGE 10/29

WD030-JABBX-200A FROM CARGO HOLD BILGE MAIN LINE


WDE01
(150A)

BWN15
S.W.CROSS MAIN IN E/R
TP
A.P.TK 12

A A
SHEET No. PAPER SIZE
BALLASTING WITH No.2 BALLAST PUMP
7/19 A3
DATE REV. No. DRAWING No. SCALE
04/03/2022 -- 21468-P-PD-01 N/A

6 5 4 3 2 1
8 7 6 5 4 3 2 1
LEGEND:

PRELIMINARY
DENOTES EXISTING LINE
DENOTES NEW LINE
STATIONARY BA111-JASBL-350A Note : 1. * marked valves (4EA) to have a throttling function. DENOTES FLUID FLOW
HAND PUMP 2. ! marked items to be supplied by the pump maker.
BA120 3. # marked items to be supplied by the V.R.C system maker. TP TIE-IN POINT

H
F (10K-350A) 4. F : Full Flooding SEE TYPICAL ''A" F
5. P.F : Partial Flooding
TP BA603-
11 JASBL-400A

MBL-11 DN350
DN50 MAIN DECK
TO TROS

BA216 BA217
DN50

(10K)
VOID (P) BA604-
FROM BIS
DN50 JACAX-400A
TO TROS NO.4
NO.6 NO.5 NO.3 W.B.TK. NO.2 W.B.TK. NO.1 W.B.TK.
DN50 W.B.TK.(P)
TO G2S H.F.O.TK.(P) H.F.O.TK.(P) (P) (P) (P)
TP
10

BA406-JAFAX-250A

BA404-JAFAX-250A

BA402-JAFAX-250A
ENGINE ROOM
NO.6 NO.4 NO.2
TP NO.7 NO.5 NO.5 NO.1
C/H C/H C/H
04 BA126 BA122 C/H C/H C/H C/H
(P.F) (F) (P.F)
BA125 BA121
BA118 PI B.S.E CP

H BA113
BA116-JABAX-250A

BA214-JACAX-
BA216-JACAX-

BA212-JACAX-
A.P.TK BALLAST WELL WITH COVER
(5K-300A) A

BA218-JACAX-
BAxxx-JACAX-xxxA
(TYPICAL)

PI

BA115-JABAX-250A
BA118-JABAX-300A

BA120-JACAX-

BA210-JACAX-
E E

300A
300A

300A
SEE NOTE (TYP.)
TP

BA123
BA124

BA114-JABAX-400A
350x400

350A
BA117-JABAX- 07

350A
250A
MBL-01

TP BA113-JABAX-350A

300A
06

(250A)
BA112

BA111

(250A)
BA208-JACAX- BA206-JACAX-

(250A)

H
BA110

BA117
* * * * NO.6 300A 300A

BA219
BA204-JACAX-300A

* H
BA108-JABAX-350A

H
PT PI CP PT

BA102

BA211

BA209

BA207

BA213

BA205

BA203
* PI
! ! CP * W.B.TK. (P)
BA201

S.W.CROSS MAIN IN E/R


BA108 BA104

H
H

H
BA116-JABAX-250A

H
* H BA115 ! ! H H

BA203-

(SEE .DA700M001)
BA106- BA102-JABAX-400A
(350A) NO.5 BA202-JACAX-400A Sliding type Expansion Coupling (FCD/NBR) JACAX-300A
JABAX-350A NO.2 W.B.P/P BA104-
H
W.B.TK. (P) Quantity and location will be defined in detail design stage.
TP (1200m3/h x 25m) JABAX-400A

(250A)
BA116

BA127
DN350

03 H BA106 F.P.TK

H
* PT * PI CP * PT *
* PI
! ! CP * BA101-JABAX-400A BA201-JACAX-400A
BA107 BA105- BA103
* H BA114 ! ! H
JABAX-350A

BA210

BA208

BA206

BA212

BA203
BA101

BA218

BA204

H
H

H
H

H
(350A) NO.6 NO.5 BA207-JACAX- BA205-JACAX-
H W.B.TK. (S) W.B.TK. (S)
MBL-01

NO.1 W.B.P/P BA103- 300A 300A


BA109

TP

BA209-JACAX-
BA119-JACAX-
(1200m3/h x 25m) JABAX-400A
BA109-JABAX-350A

H *

01
D BA105
BA217-JACAX- D

350A
BA213-JACAX-

BA211-JACAX-
BA215-JACAX-
BA112-JABAX-350A
TP 350A
02

300A

300A

300A
300A
350x400

TP
350x400

05
LS SACRIFICE FLANGE
A.P.TK
A

BA403-JAFAX-250A

BA401-JAFAX-250A
BA405-JAFAX-250A
V1-01
NOTE 3 NO.6 NO.4 NO.2
NO.5 NO.1
BWN03

NO.7 NO.3 C/H


C/H C/H C/H C/H
TP C/H C/H (P.F)
(P.F) (F)
08
MBL-10 DN350

DN50
TO TROS

BA215 BA214
DN50 NO.4 W.B.TK. CORRESPONDING
NO.6 NO.5
FROM BIS (S) NO.3 W.B.TK. NO.2 W.B.TK. PIPE (250A)
DN50 H.F.O.TK.(S) H.F.O.TK.(S) NO.1 W.B.TK.
TO TROS BA602 (S) (S) (S)

(10K)
DN50 JACAX-400A
TO G2S VOID (S)

C STATIONARY BA601 ON MAIN DECK C


HAND PUMP JASBL-400A CORRESPONDING CORRESPONDING
TP
DN400

DN50 PIPE (250A) TRUNK


09 FROM TROR IN W.B.TK
(TYPICAL)
DN50
FROM TROR
H

BA119 MBL-09 DN150


C (Next Page)
(10K-350A) TYPICAL SECTION
BWN13 BWN14
BA110
MBL-03

WATER BALLAST OVERBOARD -JASBL TYPICAL ''A''


-350A NOTE 3
BELOW LIGHT BALLAST WATER LINE

15
V1-03
LS STPG370 SMLS
BWN01

LS
16.0T (400A)
FM-1-A ELECTROLYTIC CELL
DN50
DN100

350x400 350x400 V3-02 (C-1-A)


NOTE 3 NOTE 3 V3-01 MAIN DECK
S
MBL-01

NOTE 3 NOTE 3
ABT.1.3M
PRV-1-A
TO TROS

DN400
Spool for future NOTE 3
installation of (10K 400A)

ABT 2MM
W.B.TK(P) W.B.TK(S)
SMD-1-A
Vacuum Relief Valve NO.4 C/H OVERFLOW PIPE
NOTE 3
B DN15 B
DN80
FROM DRAIN TANK STPG370 ERW 12.7T(400A)

SIDE SHELL
MBL-02
INSIDE

SLEEVE
WELDING
MBL-08 DN150 INTER-CONNECTION PIPE CARGO HOLD
B (Next Page) STPG370 SMLS 16.0T(250A)
NOTE 3
BWN10 BWN11 BWN12 ARRANGED IN C/HOLD
SET TO 5bar SLEEVE JOIN
MBL-01 DN400 FILTER
F-1-A
V1-02 BWN02
NOTE 3
SWP1 LOWER STOOL
NOTE 3
V5-01-A

MBL-06 MBL-07 H H
D (Next Page)
DN65 DN65
BWN07 65x50 65X32 BWN08 V6-01 BWN09
NOTE 3 NOTE 3
MBL-04
DN80

400A 400A
SP-1-A W.B.TK(P) W.B.TK(S)
MBL-05
DN80
BWN06 BWN05 80x40 80x65 BWN04
NOTE 3
A A
BALLASTING APT WITH No.1 SHEET No. PAPER SIZE
BILGE,FIRE & G/S PUMP 8/19 A2
DATE REV. No. DRAWING No. SCALE
04/03/2022 -- 21468-P-PD-01 N/A

8 7 6 5 4 3 2 1
6 5 4 3 2 1
LEGEND:

PRELIMINARY
DENOTES EXISTING LINE
DENOTES NEW LINE
DENOTES FLUID FLOW

TP TIE-IN POINT

(125A)
WDE16
D IN ENGINE D
CASING UPPER DECK
WD032-JABBX-50A

WDE15

WD091-JABBX-80A
ENGINE WD132-JABBX-50A
WDE14
ROOM WD036-JABBX-50A 1ST P.F DECK
WDE13
WD014 WD035-JABBX-50A
HOLD BILGE
EDUCTOR WDE12
WD033-JABBX-50A 2ND P.F DECK
BSE06
S/G RM. (65A) WDE17 WDE11
(80A)
WD130-JABBX-50A
TP TP
C WDE10 C
WD107 WD106 N.C. 15 14
BG203 WD039-JABBX-125A WD131-JABBX-50A FLOOR
TO BILGE OVBD H MBL-12 DN250 (250A)
WD015

BG104-JACBX-250A
OIL COOLER DA700M001-23

DN50
DN50
DN50
DN50
FOR DK MACH. 10K
(10K-200A)
L.O
WDE09 BG102 WDE07 WDE08 BG101 WDE06

WD045-JABBX-200A
TO TROS
E/R

TO TROS
TO G2S

FROM BIS
* PT * PI
PI * PT *
* PI
! *
! PI

! !
NO.2 BILGE, FIRE & NO.1
* PT * CP
G/S PUMPs CP * PT *
D (Previous Page)

* CP
! (90/250 M3/H ! CP *
C (Previous Page)

! X 75/25 mTH) !
B B
B (Previous Page)
SACRIFACE FLANGE

BG045 BG044
(250A) (250A) (250A) (250A)
MBL-06

(10K,200A)

(10K,200A)
DN65

WDE02
WDE03

BG042
BG043
WDE05

WDE04

N.C
N.C
MBL-08
DN150

TP
MBL-09

L.O
DN150

(5K,200A)
13

(5K,200A)
SEE PAGE 10/29

WD030-JABBX-200A FROM CARGO HOLD BILGE MAIN LINE


WDE01
(150A)

BWN15
S.W.CROSS MAIN IN E/R
TP
A.P.TK 12

A A
BALLASTING APT WITH No.1 SHEET No. PAPER SIZE
BILGE,FIRE & G/S PUMP 9/19 A3
DATE REV. No. DRAWING No. SCALE
04/03/2022 -- 21468-P-PD-01 N/A

6 5 4 3 2 1
8 7 6 5 4 3 2 1
LEGEND:

PRELIMINARY
DENOTES EXISTING LINE
DENOTES NEW LINE
STATIONARY BA111-JASBL-350A Note : 1. * marked valves (4EA) to have a throttling function. DENOTES FLUID FLOW
HAND PUMP 2. ! marked items to be supplied by the pump maker.
BA120 3. # marked items to be supplied by the V.R.C system maker. TP TIE-IN POINT

H
F (10K-350A) 4. F : Full Flooding SEE TYPICAL ''A" F
5. P.F : Partial Flooding
TP BA603-
11 JASBL-400A

MBL-11 DN350
DN50 MAIN DECK
TO TROS

BA216 BA217
DN50

(10K)
VOID (P) BA604-
FROM BIS
DN50 JACAX-400A
TO TROS NO.4
NO.6 NO.5 NO.3 W.B.TK. NO.2 W.B.TK. NO.1 W.B.TK.
DN50 W.B.TK.(P)
TO G2S H.F.O.TK.(P) H.F.O.TK.(P) (P) (P) (P)
TP
10

BA406-JAFAX-250A

BA404-JAFAX-250A

BA402-JAFAX-250A
ENGINE ROOM
NO.6 NO.4 NO.2
TP NO.7 NO.5 NO.5 NO.1
C/H C/H C/H
04 BA126 BA122 C/H C/H C/H C/H
(P.F) (F) (P.F)
BA125 BA121
BA118 PI B.S.E CP

H BA113
BA116-JABAX-250A

BA214-JACAX-
BA216-JACAX-

BA212-JACAX-
A.P.TK BALLAST WELL WITH COVER
(5K-300A) A

BA218-JACAX-
BAxxx-JACAX-xxxA
(TYPICAL)

PI

BA115-JABAX-250A
BA118-JABAX-300A

BA120-JACAX-

BA210-JACAX-
E E

300A
300A

300A
SEE NOTE (TYP.)
TP

BA123
BA124

BA114-JABAX-400A
350x400

350A
BA117-JABAX- 07

350A
250A
MBL-01

TP BA113-JABAX-350A

300A
06

(250A)
BA112

BA111

(250A)
BA208-JACAX- BA206-JACAX-

(250A)

H
BA110

BA117
* * * * NO.6 300A 300A

BA219
BA204-JACAX-300A

* H
BA108-JABAX-350A

H
PT PI CP PT

BA102

BA211

BA209

BA207

BA213

BA205

BA203
* PI
! ! CP * W.B.TK. (P)
BA201

S.W.CROSS MAIN IN E/R


BA108 BA104

H
H

H
BA116-JABAX-250A

H
* H BA115 ! ! H H

BA203-

(SEE .DA700M001)
BA106- BA102-JABAX-400A
(350A) NO.5 BA202-JACAX-400A Sliding type Expansion Coupling (FCD/NBR) JACAX-300A
JABAX-350A NO.2 W.B.P/P BA104-
H
W.B.TK. (P) Quantity and location will be defined in detail design stage.
TP (1200m3/h x 25m) JABAX-400A

(250A)
BA116

BA127
DN350

03 H BA106 F.P.TK

H
* PT * PI CP * PT *
* PI
! ! CP * BA101-JABAX-400A BA201-JACAX-400A
BA107 BA105- BA103
* H BA114 ! ! H
JABAX-350A

BA210

BA208

BA206

BA212

BA203
BA101

BA218

BA204

H
H

H
H

H
(350A) NO.6 NO.5 BA207-JACAX- BA205-JACAX-
H W.B.TK. (S) W.B.TK. (S)
MBL-01

NO.1 W.B.P/P BA103- 300A 300A


BA109

TP

BA209-JACAX-
BA119-JACAX-
(1200m3/h x 25m) JABAX-400A
BA109-JABAX-350A

H *

01
D BA105
BA217-JACAX- D

350A
BA213-JACAX-

BA211-JACAX-
BA215-JACAX-
BA112-JABAX-350A
TP 350A
02

300A

300A

300A
300A
350x400

TP
350x400

05
LS SACRIFICE FLANGE
A.P.TK
A

BA403-JAFAX-250A

BA401-JAFAX-250A
BA405-JAFAX-250A
V1-01
NOTE 3 NO.6 NO.4 NO.2
NO.5 NO.1
BWN03

NO.7 NO.3 C/H


C/H C/H C/H C/H
TP C/H C/H (P.F)
(P.F) (F)
08
MBL-10 DN350

DN50
TO TROS

BA215 BA214
DN50 NO.4 W.B.TK. CORRESPONDING
NO.6 NO.5
FROM BIS (S) NO.3 W.B.TK. NO.2 W.B.TK. PIPE (250A)
DN50 H.F.O.TK.(S) H.F.O.TK.(S) NO.1 W.B.TK.
TO TROS BA602 (S) (S) (S)

(10K)
DN50 JACAX-400A
TO G2S VOID (S)

C STATIONARY BA601 ON MAIN DECK C


HAND PUMP JASBL-400A CORRESPONDING CORRESPONDING
TP
DN400

DN50 PIPE (250A) TRUNK


09 FROM TROR IN W.B.TK
(TYPICAL)
DN50
FROM TROR
H

BA119 MBL-09 DN150


C (Next Page)
(10K-350A) TYPICAL SECTION
BWN13 BWN14
BA110
MBL-03

WATER BALLAST OVERBOARD -JASBL TYPICAL ''A''


-350A NOTE 3
BELOW LIGHT BALLAST WATER LINE

15
V1-03
LS STPG370 SMLS
BWN01

LS
16.0T (400A)
FM-1-A ELECTROLYTIC CELL
DN50
DN100

350x400 350x400 V3-02 (C-1-A)


NOTE 3 NOTE 3 V3-01 MAIN DECK
S
MBL-01

NOTE 3 NOTE 3
ABT.1.3M
PRV-1-A
TO TROS

DN400
Spool for future NOTE 3
installation of (10K 400A)

ABT 2MM
W.B.TK(P) W.B.TK(S)
SMD-1-A
Vacuum Relief Valve NO.4 C/H OVERFLOW PIPE
NOTE 3
B DN15 B
DN80
FROM DRAIN TANK STPG370 ERW 12.7T(400A)

SIDE SHELL
MBL-02
INSIDE

SLEEVE
WELDING
MBL-08 DN150 INTER-CONNECTION PIPE CARGO HOLD
B (Next Page) STPG370 SMLS 16.0T(250A)
NOTE 3
BWN10 BWN11 BWN12 ARRANGED IN C/HOLD
SET TO 5bar SLEEVE JOIN
MBL-01 DN400 FILTER
F-1-A
V1-02 BWN02
NOTE 3
SWP1 LOWER STOOL
NOTE 3
V5-01-A

MBL-06 MBL-07 H H
D (Next Page)
DN65 DN65
BWN07 65x50 65X32 BWN08 V6-01 BWN09
NOTE 3 NOTE 3
MBL-04
DN80

400A 400A
SP-1-A W.B.TK(P) W.B.TK(S)
MBL-05
DN80
BWN06 BWN05 80x40 80x65 BWN04
NOTE 3
A A
BALLASTING APT WITH No.2 SHEET No. PAPER SIZE
BILGE,FIRE & G/S PUMP 10/19 A2
DATE REV. No. DRAWING No. SCALE
04/03/2022 -- 21468-P-PD-01 N/A

8 7 6 5 4 3 2 1
6 5 4 3 2 1
LEGEND:

PRELIMINARY
DENOTES EXISTING LINE
DENOTES NEW LINE
DENOTES FLUID FLOW

TP TIE-IN POINT

(125A)
WDE16
D IN ENGINE D
CASING UPPER DECK
WD032-JABBX-50A

WDE15

WD091-JABBX-80A
ENGINE WD132-JABBX-50A
WDE14
ROOM WD036-JABBX-50A 1ST P.F DECK
WDE13
WD014 WD035-JABBX-50A
HOLD BILGE
EDUCTOR WDE12
WD033-JABBX-50A 2ND P.F DECK
BSE06
S/G RM. (65A) WDE17 WDE11
(80A)
WD130-JABBX-50A
TP TP
C WDE10 C
WD107 WD106 N.C. 15 14
BG203 WD039-JABBX-125A WD131-JABBX-50A FLOOR
TO BILGE OVBD H MBL-12 DN250 (250A)
WD015

BG104-JACBX-250A
OIL COOLER DA700M001-23

DN50
DN50
DN50
DN50
FOR DK MACH. 10K
(10K-200A)
L.O
WDE09 BG102 WDE07 WDE08 BG101 WDE06

WD045-JABBX-200A
TO TROS
E/R

TO TROS
TO G2S

FROM BIS
* PT * PI
PI * PT *
* PI
! *
! PI

! !
NO.2 BILGE, FIRE & NO.1
* PT * CP
G/S PUMPs CP * PT *
D (Previous Page)

* CP
! (90/250 M3/H ! CP *
C (Previous Page)

! X 75/25 mTH) !
B B
B (Previous Page)
SACRIFACE FLANGE

BG045 BG044
(250A) (250A) (250A) (250A)
MBL-06

(10K,200A)

(10K,200A)
DN65

WDE02
WDE03

BG042
BG043
WDE05

WDE04

N.C
N.C
MBL-08
DN150

TP
MBL-09

L.O
DN150

(5K,200A)
13

(5K,200A)
SEE PAGE 10/29

WD030-JABBX-200A FROM CARGO HOLD BILGE MAIN LINE


WDE01
(150A)

BWN15
S.W.CROSS MAIN IN E/R
TP
A.P.TK 12

A A
BALLASTING APT WITH No.2 SHEET No. PAPER SIZE
BILGE,FIRE & G/S PUMP 11/19 A3
DATE REV. No. DRAWING No. SCALE
04/03/2022 -- 21468-P-PD-01 N/A

6 5 4 3 2 1
8 7 6 5 4 3 2 1
LEGEND:

PRELIMINARY
DENOTES EXISTING LINE
DENOTES NEW LINE
STATIONARY BA111-JASBL-350A Note : 1. * marked valves (4EA) to have a throttling function. DENOTES FLUID FLOW
HAND PUMP 2. ! marked items to be supplied by the pump maker.
BA120 3. # marked items to be supplied by the V.R.C system maker. TP TIE-IN POINT

H
F (10K-350A) 4. F : Full Flooding SEE TYPICAL ''A" F
5. P.F : Partial Flooding
TP BA603-
11 JASBL-400A

MBL-11 DN350
DN50 MAIN DECK
TO TROS

BA216 BA217
DN50

(10K)
VOID (P) BA604-
FROM BIS
DN50 JACAX-400A
TO TROS NO.4
NO.6 NO.5 NO.3 W.B.TK. NO.2 W.B.TK. NO.1 W.B.TK.
DN50 W.B.TK.(P)
TO G2S H.F.O.TK.(P) H.F.O.TK.(P) (P) (P) (P)
TP
10

BA406-JAFAX-250A

BA404-JAFAX-250A

BA402-JAFAX-250A
ENGINE ROOM
NO.6 NO.4 NO.2
TP NO.7 NO.5 NO.5 NO.1
C/H C/H C/H
04 BA126 BA122 C/H C/H C/H C/H
(P.F) (F) (P.F)
BA125 BA121
BA118 PI B.S.E CP

H BA113
BA116-JABAX-250A

BA214-JACAX-
BA216-JACAX-

BA212-JACAX-
A.P.TK BALLAST WELL WITH COVER
(5K-300A) A

BA218-JACAX-
BAxxx-JACAX-xxxA
(TYPICAL)

PI

BA115-JABAX-250A
BA118-JABAX-300A

BA120-JACAX-

BA210-JACAX-
E E

300A
300A

300A
SEE NOTE (TYP.)
TP

BA123
BA124

BA114-JABAX-400A
350x400

350A
BA117-JABAX- 07

350A
250A
MBL-01

TP BA113-JABAX-350A

300A
06

(250A)
BA112

BA111

(250A)
BA208-JACAX- BA206-JACAX-

(250A)

H
BA110

BA117
* * * * NO.6 300A 300A

BA219
BA204-JACAX-300A

* H
BA108-JABAX-350A

H
PT PI CP PT

BA102

BA211

BA209

BA207

BA213

BA205

BA203
* PI
! ! CP * W.B.TK. (P)
BA201

S.W.CROSS MAIN IN E/R


BA108 BA104

H
H

H
BA116-JABAX-250A

H
* H BA115 ! ! H H

BA203-

(SEE .DA700M001)
BA106- BA102-JABAX-400A
(350A) NO.5 BA202-JACAX-400A Sliding type Expansion Coupling (FCD/NBR) JACAX-300A
JABAX-350A NO.2 W.B.P/P BA104-
H
W.B.TK. (P) Quantity and location will be defined in detail design stage.
TP (1200m3/h x 25m) JABAX-400A

(250A)
BA116

BA127
DN350

03 H BA106 F.P.TK

H
* PT * PI CP * PT *
* PI
! ! CP * BA101-JABAX-400A BA201-JACAX-400A
BA107 BA105- BA103
* H BA114 ! ! H
JABAX-350A

BA210

BA208

BA206

BA212

BA203
BA101

BA218

BA204

H
H

H
H

H
(350A) NO.6 NO.5 BA207-JACAX- BA205-JACAX-
H W.B.TK. (S) W.B.TK. (S)
MBL-01

NO.1 W.B.P/P BA103- 300A 300A


BA109

TP

BA209-JACAX-
BA119-JACAX-
(1200m3/h x 25m) JABAX-400A
BA109-JABAX-350A

H *

01
D BA105
BA217-JACAX- D

350A
BA213-JACAX-

BA211-JACAX-
BA215-JACAX-
BA112-JABAX-350A
TP 350A
02

300A

300A

300A
300A
350x400

TP
350x400

05
LS SACRIFICE FLANGE
A.P.TK
A

BA403-JAFAX-250A

BA401-JAFAX-250A
BA405-JAFAX-250A
V1-01
NOTE 3 NO.6 NO.4 NO.2
NO.5 NO.1
BWN03

NO.7 NO.3 C/H


C/H C/H C/H C/H
TP C/H C/H (P.F)
(P.F) (F)
08
MBL-10 DN350

DN50
TO TROS

BA215 BA214
DN50 NO.4 W.B.TK. CORRESPONDING
NO.6 NO.5
FROM BIS (S) NO.3 W.B.TK. NO.2 W.B.TK. PIPE (250A)
DN50 H.F.O.TK.(S) H.F.O.TK.(S) NO.1 W.B.TK.
TO TROS BA602 (S) (S) (S)

(10K)
DN50 JACAX-400A
TO G2S VOID (S)

C STATIONARY BA601 ON MAIN DECK C


HAND PUMP JASBL-400A CORRESPONDING CORRESPONDING
TP
DN400

DN50 PIPE (250A) TRUNK


09 FROM TROR IN W.B.TK
(TYPICAL)
DN50
FROM TROR
H

BA119 MBL-09 DN150


C (Next Page)
(10K-350A) TYPICAL SECTION
BWN13 BWN14
BA110
MBL-03

WATER BALLAST OVERBOARD -JASBL TYPICAL ''A''


-350A NOTE 3
BELOW LIGHT BALLAST WATER LINE

15
V1-03
LS STPG370 SMLS
BWN01

LS
16.0T (400A)
FM-1-A ELECTROLYTIC CELL
DN50
DN100

350x400 350x400 V3-02 (C-1-A)


NOTE 3 NOTE 3 V3-01 MAIN DECK
S
MBL-01

NOTE 3 NOTE 3
ABT.1.3M
PRV-1-A
TO TROS

DN400
Spool for future NOTE 3
installation of (10K 400A)

ABT 2MM
W.B.TK(P) W.B.TK(S)
SMD-1-A
Vacuum Relief Valve NO.4 C/H OVERFLOW PIPE
NOTE 3
B DN15 B
DN80
FROM DRAIN TANK STPG370 ERW 12.7T(400A)

SIDE SHELL
MBL-02
INSIDE

SLEEVE
WELDING
MBL-08 DN150 INTER-CONNECTION PIPE CARGO HOLD
B (Next Page) STPG370 SMLS 16.0T(250A)
NOTE 3
BWN10 BWN11 BWN12 ARRANGED IN C/HOLD
SET TO 5bar SLEEVE JOIN
MBL-01 DN400 FILTER
F-1-A
V1-02 BWN02
NOTE 3
SWP1 LOWER STOOL
NOTE 3
V5-01-A

MBL-06 MBL-07 H H
D (Next Page)
DN65 DN65
BWN07 65x50 65X32 BWN08 V6-01 BWN09
NOTE 3 NOTE 3
MBL-04
DN80

400A 400A
SP-1-A W.B.TK(P) W.B.TK(S)
MBL-05
DN80
BWN06 BWN05 80x40 80x65 BWN04
NOTE 3
A A
DE-BALLASTING WITH No.1 AND/OR No.2 SHEET No. PAPER SIZE
BALLAST PUMP [BA119 & BA120] 12/19 A2
DATE REV. No. DRAWING No. SCALE
04/03/2022 -- 21468-P-PD-01 N/A

8 7 6 5 4 3 2 1
6 5 4 3 2 1
LEGEND:

PRELIMINARY
DENOTES EXISTING LINE
DENOTES NEW LINE

TP TIE-IN POINT

(125A)
WDE16
D IN ENGINE D
CASING UPPER DECK
WD032-JABBX-50A

WDE15

WD091-JABBX-80A
ENGINE WD132-JABBX-50A
WDE14
ROOM WD036-JABBX-50A 1ST P.F DECK
WDE13
WD014 WD035-JABBX-50A
HOLD BILGE
EDUCTOR WDE12
WD033-JABBX-50A 2ND P.F DECK
BSE06
S/G RM. (65A) WDE17 WDE11
(80A)
WD130-JABBX-50A
TP TP
C WDE10 C
WD107 WD106 N.C. 15 14
BG203 WD039-JABBX-125A WD131-JABBX-50A FLOOR
TO BILGE OVBD H MBL-12 DN250 (250A)
WD015

BG104-JACBX-250A
OIL COOLER DA700M001-23

DN50
DN50
DN50
DN50
FOR DK MACH. 10K
(10K-200A)
L.O
WDE09 BG102 WDE07 WDE08 BG101 WDE06

WD045-JABBX-200A
TO TROS
E/R

TO TROS
TO G2S

FROM BIS
* PT * PI
PI * PT *
* PI
! *
! PI

! !
NO.2 BILGE, FIRE & NO.1
* PT * CP
G/S PUMPs CP * PT *
D (Previous Page)

* CP
! (90/250 M3/H ! CP *
C (Previous Page)

! X 75/25 mTH) !
B B
B (Previous Page)
SACRIFACE FLANGE

BG045 BG044
(250A) (250A) (250A) (250A)
MBL-06

(10K,200A)

(10K,200A)
DN65

WDE02
WDE03

BG042
BG043
WDE05

WDE04

N.C
N.C
MBL-08
DN150

TP
MBL-09

L.O
DN150

(5K,200A)
13

(5K,200A)
SEE PAGE 10/29

WD030-JABBX-200A FROM CARGO HOLD BILGE MAIN LINE


WDE01
(150A)

BWN15
S.W.CROSS MAIN IN E/R
TP
A.P.TK 12

A A
DE-BALLASTING WITH No.1 AND/OR No.2 SHEET No. PAPER SIZE
BALLAST PUMP [BA119 & BA120] 13/19 A3
DATE REV. No. DRAWING No. SCALE
04/03/2022 -- 21468-P-PD-01 N/A

6 5 4 3 2 1
8 7 6 5 4 3 2 1
LEGEND:

PRELIMINARY
DENOTES EXISTING LINE
DENOTES NEW LINE
STATIONARY BA111-JASBL-350A Note : 1. * marked valves (4EA) to have a throttling function.
2. ! marked items to be supplied by the pump maker. TP TIE-IN POINT
HAND PUMP
BA120 3. # marked items to be supplied by the V.R.C system maker.

H
F (10K-350A) 4. F : Full Flooding SEE TYPICAL ''A" F
5. P.F : Partial Flooding
TP BA603-
11 JASBL-400A

MBL-11 DN350
DN50 MAIN DECK
TO TROS

BA216 BA217
DN50

(10K)
VOID (P) BA604-
FROM BIS
DN50 JACAX-400A
TO TROS NO.4
NO.6 NO.5 NO.3 W.B.TK. NO.2 W.B.TK. NO.1 W.B.TK.
DN50 W.B.TK.(P)
TO G2S H.F.O.TK.(P) H.F.O.TK.(P) (P) (P) (P)
TP
10

BA406-JAFAX-250A

BA404-JAFAX-250A

BA402-JAFAX-250A
ENGINE ROOM
NO.6 NO.4 NO.2
TP NO.7 NO.5 NO.5 NO.1
C/H C/H C/H
04 BA126 BA122 C/H C/H C/H C/H
(P.F) (F) (P.F)
BA125 BA121
BA118 PI B.S.E CP

H BA113
BA116-JABAX-250A

BA214-JACAX-
BA216-JACAX-

BA212-JACAX-
A.P.TK BALLAST WELL WITH COVER
(5K-300A) A

BA218-JACAX-
BAxxx-JACAX-xxxA
(TYPICAL)

PI

BA115-JABAX-250A
BA118-JABAX-300A

BA120-JACAX-

BA210-JACAX-
E E

300A
300A

300A
SEE NOTE (TYP.)
TP

BA123
BA124

BA114-JABAX-400A
350x400

350A
BA117-JABAX- 07

350A
250A
MBL-01

TP BA113-JABAX-350A

300A
06

(250A)
BA112

BA111

(250A)
BA208-JACAX- BA206-JACAX-

(250A)

H
BA110

BA117
* * * * NO.6 300A 300A

BA219
BA204-JACAX-300A

* H
BA108-JABAX-350A

H
PT PI CP PT

BA102

BA211

BA209

BA207

BA213

BA205

BA203
* PI
! ! CP * W.B.TK. (P)
BA201

S.W.CROSS MAIN IN E/R


BA108 BA104

H
H

H
BA116-JABAX-250A

H
* H BA115 ! ! H H

BA203-

(SEE .DA700M001)
BA106- BA102-JABAX-400A
(350A) NO.5 BA202-JACAX-400A Sliding type Expansion Coupling (FCD/NBR) JACAX-300A
JABAX-350A NO.2 W.B.P/P BA104-
H
W.B.TK. (P) Quantity and location will be defined in detail design stage.
TP (1200m3/h x 25m) JABAX-400A

(250A)
BA116

BA127
DN350

03 H BA106 F.P.TK

H
* PT * PI CP * PT *
* PI
! ! CP * BA101-JABAX-400A BA201-JACAX-400A
BA107 BA105- BA103
* H BA114 ! ! H
JABAX-350A

BA210

BA208

BA206

BA212

BA203
BA101

BA218

BA204

H
H

H
H

H
(350A) NO.6 NO.5 BA207-JACAX- BA205-JACAX-
H W.B.TK. (S) W.B.TK. (S)
MBL-01

NO.1 W.B.P/P BA103- 300A 300A


BA109

TP

BA209-JACAX-
BA119-JACAX-
(1200m3/h x 25m) JABAX-400A
BA109-JABAX-350A

H *

01
D BA105
BA217-JACAX- D

350A
BA213-JACAX-

BA211-JACAX-
BA215-JACAX-
BA112-JABAX-350A
TP 350A
02

300A

300A

300A
300A
350x400

TP
350x400

05
LS SACRIFICE FLANGE
A.P.TK
A

BA403-JAFAX-250A

BA401-JAFAX-250A
BA405-JAFAX-250A
V1-01
NOTE 3 NO.6 NO.4 NO.2
NO.5 NO.1
BWN03

NO.7 NO.3 C/H


C/H C/H C/H C/H
TP C/H C/H (P.F)
(P.F) (F)
08
MBL-10 DN350

DN50
TO TROS

BA215 BA214
DN50 NO.4 W.B.TK. CORRESPONDING
NO.6 NO.5
FROM BIS (S) NO.3 W.B.TK. NO.2 W.B.TK. PIPE (250A)
DN50 H.F.O.TK.(S) H.F.O.TK.(S) NO.1 W.B.TK.
TO TROS BA602 (S) (S) (S)

(10K)
DN50 JACAX-400A
TO G2S VOID (S)

C STATIONARY BA601 ON MAIN DECK C


HAND PUMP JASBL-400A CORRESPONDING CORRESPONDING
TP
DN400

DN50 PIPE (250A) TRUNK


09 FROM TROR IN W.B.TK
(TYPICAL)
DN50
FROM TROR
H

BA119 MBL-09 DN150


C (Next Page)
(10K-350A) TYPICAL SECTION
BWN13 BWN14
BA110
MBL-03

WATER BALLAST OVERBOARD -JASBL TYPICAL ''A''


-350A NOTE 3
BELOW LIGHT BALLAST WATER LINE

15
V1-03
LS STPG370 SMLS
BWN01

LS
16.0T (400A)
FM-1-A ELECTROLYTIC CELL
DN50
DN100

350x400 350x400 V3-02 (C-1-A)


NOTE 3 NOTE 3 V3-01 MAIN DECK
S
MBL-01

NOTE 3 NOTE 3
ABT.1.3M
PRV-1-A
TO TROS

DN400
Spool for future NOTE 3
installation of (10K 400A)

ABT 2MM
W.B.TK(P) W.B.TK(S)
SMD-1-A
Vacuum Relief Valve NO.4 C/H OVERFLOW PIPE
NOTE 3
B DN15 B
DN80
FROM DRAIN TANK STPG370 ERW 12.7T(400A)

SIDE SHELL
MBL-02
INSIDE

SLEEVE
WELDING
MBL-08 DN150 INTER-CONNECTION PIPE CARGO HOLD
B (Next Page) STPG370 SMLS 16.0T(250A)
NOTE 3
BWN10 BWN11 BWN12 ARRANGED IN C/HOLD
SET TO 5bar SLEEVE JOIN
MBL-01 DN400 FILTER
F-1-A
V1-02 BWN02
NOTE 3
SWP1 LOWER STOOL
NOTE 3
V5-01-A

MBL-06 MBL-07 H H
D (Next Page)
DN65 DN65
BWN07 65x50 65X32 BWN08 V6-01 BWN09
NOTE 3 NOTE 3
MBL-04
DN80

400A 400A
SP-1-A W.B.TK(P) W.B.TK(S)
MBL-05
DN80
BWN06 BWN05 80x40 80x65 BWN04
NOTE 3
A A
DE-BALLASTING APT WITH No.1 AND/OR No.2 SHEET No. PAPER SIZE
BILGE, FIRE & G/S PUMP [BG203] 14/19 A2
DATE REV. No. DRAWING No. SCALE
04/03/2022 -- 21468-P-PD-01 N/A

8 7 6 5 4 3 2 1
6 5 4 3 2 1
LEGEND:

PRELIMINARY
DENOTES EXISTING LINE
DENOTES NEW LINE
DENOTES FLUID FLOW

TP TIE-IN POINT

(125A)
WDE16
D IN ENGINE D
CASING UPPER DECK
WD032-JABBX-50A

WDE15

WD091-JABBX-80A
ENGINE WD132-JABBX-50A
WDE14
ROOM WD036-JABBX-50A 1ST P.F DECK
WDE13
WD014 WD035-JABBX-50A
HOLD BILGE
EDUCTOR WDE12
WD033-JABBX-50A 2ND P.F DECK
BSE06
S/G RM. (65A) WDE17 WDE11
(80A)
WD130-JABBX-50A
TP TP
C WDE10 C
WD107 WD106 N.C. 15 14
BG203 WD039-JABBX-125A WD131-JABBX-50A FLOOR
TO BILGE OVBD H MBL-12 DN250 (250A)
WD015

BG104-JACBX-250A
OIL COOLER DA700M001-23

DN50
DN50
DN50
DN50
FOR DK MACH. 10K
(10K-200A)
L.O
WDE09 BG102 WDE07 WDE08 BG101 WDE06

WD045-JABBX-200A
TO TROS
E/R

TO TROS
TO G2S

FROM BIS
* PT * PI
PI * PT *
* PI
! *
! PI

! !
NO.2 BILGE, FIRE & NO.1
* PT * CP
G/S PUMPs CP * PT *
D (Previous Page)

* CP
! (90/250 M3/H ! CP *
C (Previous Page)

! X 75/25 mTH) !
B B
B (Previous Page)
SACRIFACE FLANGE

BG045 BG044
(250A) (250A) (250A) (250A)
MBL-06

(10K,200A)

(10K,200A)
DN65

WDE02
WDE03

BG042
BG043
WDE05

WDE04

N.C
N.C
MBL-08
DN150

TP
MBL-09

L.O
DN150

(5K,200A)
13

(5K,200A)
SEE PAGE 10/29

WD030-JABBX-200A FROM CARGO HOLD BILGE MAIN LINE


WDE01
(150A)

BWN15
S.W.CROSS MAIN IN E/R
TP
A.P.TK 12

A A
DE-BALLASTING APT WITH No.1 AND/OR No.2 SHEET No. PAPER SIZE
BILGE, FIRE & G/S PUMP [BG203] 15/19 A3
DATE REV. No. DRAWING No. SCALE
04/03/2022 -- 21468-P-PD-01 N/A

6 5 4 3 2 1
8 7 6 5 4 3 2 1
LEGEND:

PRELIMINARY
DENOTES EXISTING LINE
DENOTES NEW LINE
STATIONARY BA111-JASBL-350A Note : 1. * marked valves (4EA) to have a throttling function. DENOTES FLUID FLOW
HAND PUMP 2. ! marked items to be supplied by the pump maker. DENOTES MOTIVE WATER
BA120 3. # marked items to be supplied by the V.R.C system maker.

H
F (10K-350A) 4. F : Full Flooding SEE TYPICAL ''A" TP TIE-IN POINT F
5. P.F : Partial Flooding
TP BA603-
11 JASBL-400A

MBL-11 DN350
DN50 MAIN DECK
TO TROS

BA216 BA217
DN50

(10K)
VOID (P) BA604-
FROM BIS
DN50 JACAX-400A
TO TROS NO.4
NO.6 NO.5 NO.3 W.B.TK. NO.2 W.B.TK. NO.1 W.B.TK.
DN50 W.B.TK.(P)
TO G2S H.F.O.TK.(P) H.F.O.TK.(P) (P) (P) (P)
TP
10

BA406-JAFAX-250A

BA404-JAFAX-250A

BA402-JAFAX-250A
ENGINE ROOM
NO.6 NO.4 NO.2
TP NO.7 NO.5 NO.5 NO.1
C/H C/H C/H
04 BA126 BA122 C/H C/H C/H C/H
(P.F) (F) (P.F)
BA125 BA121
BA118 PI B.S.E CP

H BA113
BA116-JABAX-250A

BA214-JACAX-
BA216-JACAX-

BA212-JACAX-
A.P.TK BALLAST WELL WITH COVER
(5K-300A) A

BA218-JACAX-
BAxxx-JACAX-xxxA
(TYPICAL)

PI

BA115-JABAX-250A
BA118-JABAX-300A

BA120-JACAX-

BA210-JACAX-
E E

300A
300A

300A
SEE NOTE (TYP.)
TP

BA123
BA124

BA114-JABAX-400A
350x400

350A
BA117-JABAX- 07

350A
250A
MBL-01

TP BA113-JABAX-350A

300A
06

(250A)
BA112

BA111

(250A)
BA208-JACAX- BA206-JACAX-

(250A)

H
BA110

BA117
* * * * NO.6 300A 300A

BA219
BA204-JACAX-300A

* H
BA108-JABAX-350A

H
PT PI CP PT

BA102

BA211

BA209

BA207

BA213

BA205

BA203
* PI
! ! CP * W.B.TK. (P)
BA201

S.W.CROSS MAIN IN E/R


BA108 BA104

H
H

H
BA116-JABAX-250A

H
* H BA115 ! ! H H

BA203-

(SEE .DA700M001)
BA106- BA102-JABAX-400A
(350A) NO.5 BA202-JACAX-400A Sliding type Expansion Coupling (FCD/NBR) JACAX-300A
JABAX-350A NO.2 W.B.P/P BA104-
H
W.B.TK. (P) Quantity and location will be defined in detail design stage.
TP (1200m3/h x 25m) JABAX-400A

(250A)
BA116

BA127
DN350

03 H BA106 F.P.TK

H
* PT * PI CP * PT *
* PI
! ! CP * BA101-JABAX-400A BA201-JACAX-400A
BA107 BA105- BA103
* H BA114 ! ! H
JABAX-350A

BA210

BA208

BA206

BA212

BA203
BA101

BA218

BA204

H
H

H
H

H
(350A) NO.6 NO.5 BA207-JACAX- BA205-JACAX-
H W.B.TK. (S) W.B.TK. (S)
MBL-01

NO.1 W.B.P/P BA103- 300A 300A


BA109

TP

BA209-JACAX-
BA119-JACAX-
(1200m3/h x 25m) JABAX-400A
BA109-JABAX-350A

H *

01
D BA105
BA217-JACAX- D

350A
BA213-JACAX-

BA211-JACAX-
BA215-JACAX-
BA112-JABAX-350A
TP 350A
02

300A

300A

300A
300A
350x400

TP
350x400

05
LS SACRIFICE FLANGE
A.P.TK
A

BA403-JAFAX-250A

BA401-JAFAX-250A
BA405-JAFAX-250A
V1-01
NOTE 3 NO.6 NO.4 NO.2
NO.5 NO.1
BWN03

NO.7 NO.3 C/H


C/H C/H C/H C/H
TP C/H C/H (P.F)
(P.F) (F)
08
MBL-10 DN350

DN50
TO TROS

BA215 BA214
DN50 NO.4 W.B.TK. CORRESPONDING
NO.6 NO.5
FROM BIS (S) NO.3 W.B.TK. NO.2 W.B.TK. PIPE (250A)
DN50 H.F.O.TK.(S) H.F.O.TK.(S) NO.1 W.B.TK.
TO TROS BA602 (S) (S) (S)

(10K)
DN50 JACAX-400A
TO G2S VOID (S)

C STATIONARY BA601 ON MAIN DECK C


HAND PUMP JASBL-400A CORRESPONDING CORRESPONDING
TP
DN400

DN50 PIPE (250A) TRUNK


09 FROM TROR IN W.B.TK
(TYPICAL)
DN50
FROM TROR
H

BA119 MBL-09 DN150


C (Next Page)
(10K-350A) TYPICAL SECTION
BWN13 BWN14
BA110
MBL-03

WATER BALLAST OVERBOARD -JASBL TYPICAL ''A''


-350A NOTE 3
BELOW LIGHT BALLAST WATER LINE

15
V1-03
LS STPG370 SMLS
BWN01

LS
16.0T (400A)
FM-1-A ELECTROLYTIC CELL
DN50
DN100

350x400 350x400 V3-02 (C-1-A)


NOTE 3 NOTE 3 V3-01 MAIN DECK
S
MBL-01

NOTE 3 NOTE 3
ABT.1.3M
PRV-1-A
TO TROS

DN400
Spool for future NOTE 3
installation of (10K 400A)

ABT 2MM
W.B.TK(P) W.B.TK(S)
SMD-1-A
Vacuum Relief Valve NO.4 C/H OVERFLOW PIPE
NOTE 3
B DN15 B
DN80
FROM DRAIN TANK STPG370 ERW 12.7T(400A)

SIDE SHELL
MBL-02
INSIDE

SLEEVE
WELDING
MBL-08 DN150 INTER-CONNECTION PIPE CARGO HOLD
B (Next Page) STPG370 SMLS 16.0T(250A)
NOTE 3
BWN10 BWN11 BWN12 ARRANGED IN C/HOLD
SET TO 5bar SLEEVE JOIN
MBL-01 DN400 FILTER
F-1-A
V1-02 BWN02
NOTE 3
SWP1 LOWER STOOL
NOTE 3
V5-01-A

MBL-06 MBL-07 H H
D (Next Page)
DN65 DN65
BWN07 65x50 65X32 BWN08 V6-01 BWN09
NOTE 3 NOTE 3
MBL-04
DN80

400A 400A
SP-1-A W.B.TK(P) W.B.TK(S)
MBL-05
DN80
BWN06 BWN05 80x40 80x65 BWN04
NOTE 3
A A
DE-BALLASTING BY STRIPPING SHEET No. PAPER SIZE
[BA119 & BA120] 16/19 A2
DATE REV. No. DRAWING No. SCALE
04/03/2022 -- 21468-P-PD-01 N/A

8 7 6 5 4 3 2 1
6 5 4 3 2 1
LEGEND:

PRELIMINARY
DENOTES EXISTING LINE
DENOTES NEW LINE

TP TIE-IN POINT

(125A)
WDE16
D IN ENGINE D
CASING UPPER DECK
WD032-JABBX-50A

WDE15

WD091-JABBX-80A
ENGINE WD132-JABBX-50A
WDE14
ROOM WD036-JABBX-50A 1ST P.F DECK
WDE13
WD014 WD035-JABBX-50A
HOLD BILGE
EDUCTOR WDE12
WD033-JABBX-50A 2ND P.F DECK
BSE06
S/G RM. (65A) WDE17 WDE11
(80A)
WD130-JABBX-50A
TP TP
C WDE10 C
WD107 WD106 N.C. 15 14
BG203 WD039-JABBX-125A WD131-JABBX-50A FLOOR
TO BILGE OVBD H MBL-12 DN250 (250A)
WD015

BG104-JACBX-250A
OIL COOLER DA700M001-23

DN50
DN50
DN50
DN50
FOR DK MACH. 10K
(10K-200A)
L.O
WDE09 BG102 WDE07 WDE08 BG101 WDE06

WD045-JABBX-200A
TO TROS
E/R

TO TROS
TO G2S

FROM BIS
* PT * PI
PI * PT *
* PI
! *
! PI

! !
NO.2 BILGE, FIRE & NO.1
* PT * CP
G/S PUMPs CP * PT *
D (Previous Page)

* CP
! (90/250 M3/H ! CP *
C (Previous Page)

! X 75/25 mTH) !
B B
B (Previous Page)
SACRIFACE FLANGE

BG045 BG044
(250A) (250A) (250A) (250A)
MBL-06

(10K,200A)

(10K,200A)
DN65

WDE02
WDE03

BG042
BG043
WDE05

WDE04

N.C
N.C
MBL-08
DN150

TP
MBL-09

L.O
DN150

(5K,200A)
13

(5K,200A)
SEE PAGE 10/29

WD030-JABBX-200A FROM CARGO HOLD BILGE MAIN LINE


WDE01
(150A)

BWN15
S.W.CROSS MAIN IN E/R
TP
A.P.TK 12

A A
DE-BALLASTING BY STRIPPING SHEET No. PAPER SIZE
[BA119 & BA120] 17/19 A3
DATE REV. No. DRAWING No. SCALE
04/03/2022 -- 21468-P-PD-01 N/A

6 5 4 3 2 1
8 7 6 5 4 3 2 1
LEGEND:

PRELIMINARY
DENOTES EXISTING LINE
DENOTES NEW LINE
STATIONARY BA111-JASBL-350A Note : 1. * marked valves (4EA) to have a throttling function. DENOTES FLUID FLOW
HAND PUMP 2. ! marked items to be supplied by the pump maker.
BA120 3. # marked items to be supplied by the V.R.C system maker. TP TIE-IN POINT

H
F (10K-350A) 4. F : Full Flooding SEE TYPICAL ''A" F
5. P.F : Partial Flooding
TP BA603-
11 JASBL-400A

MBL-11 DN350
DN50 MAIN DECK
TO TROS

BA216 BA217
DN50

(10K)
VOID (P) BA604-
FROM BIS
DN50 JACAX-400A
TO TROS NO.4
NO.6 NO.5 NO.3 W.B.TK. NO.2 W.B.TK. NO.1 W.B.TK.
DN50 W.B.TK.(P)
TO G2S H.F.O.TK.(P) H.F.O.TK.(P) (P) (P) (P)
TP
10

BA406-JAFAX-250A

BA404-JAFAX-250A

BA402-JAFAX-250A
ENGINE ROOM
NO.6 NO.4 NO.2
TP NO.7 NO.5 NO.5 NO.1
C/H C/H C/H
04 BA126 BA122 C/H C/H C/H C/H
(P.F) (F) (P.F)
BA125 BA121
BA118 PI B.S.E CP

H BA113
BA116-JABAX-250A

BA214-JACAX-
BA216-JACAX-

BA212-JACAX-
A.P.TK BALLAST WELL WITH COVER
(5K-300A) A

BA218-JACAX-
BAxxx-JACAX-xxxA
(TYPICAL)

PI

BA115-JABAX-250A
BA118-JABAX-300A

BA120-JACAX-

BA210-JACAX-
E E

300A
300A

300A
SEE NOTE (TYP.)
TP

BA123
BA124

BA114-JABAX-400A
350x400

350A
BA117-JABAX- 07

350A
250A
MBL-01

TP BA113-JABAX-350A

300A
06

(250A)
BA112

BA111

(250A)
BA208-JACAX- BA206-JACAX-

(250A)

H
BA110

BA117
* * * * NO.6 300A 300A

BA219
BA204-JACAX-300A

* H
BA108-JABAX-350A

H
PT PI CP PT

BA102

BA211

BA209

BA207

BA213

BA205

BA203
* PI
! ! CP * W.B.TK. (P)
BA201

S.W.CROSS MAIN IN E/R


BA108 BA104

H
H

H
BA116-JABAX-250A

H
* H BA115 ! ! H H

BA203-

(SEE .DA700M001)
BA106- BA102-JABAX-400A
(350A) NO.5 BA202-JACAX-400A Sliding type Expansion Coupling (FCD/NBR) JACAX-300A
JABAX-350A NO.2 W.B.P/P BA104-
H
W.B.TK. (P) Quantity and location will be defined in detail design stage.
TP (1200m3/h x 25m) JABAX-400A

(250A)
BA116

BA127
DN350

03 H BA106 F.P.TK

H
* PT * PI CP * PT *
* PI
! ! CP * BA101-JABAX-400A BA201-JACAX-400A
BA107 BA105- BA103
* H BA114 ! ! H
JABAX-350A

BA210

BA208

BA206

BA212

BA203
BA101

BA218

BA204

H
H

H
H

H
(350A) NO.6 NO.5 BA207-JACAX- BA205-JACAX-
H W.B.TK. (S) W.B.TK. (S)
MBL-01

NO.1 W.B.P/P BA103- 300A 300A


BA109

TP

BA209-JACAX-
BA119-JACAX-
(1200m3/h x 25m) JABAX-400A
BA109-JABAX-350A

H *

01
D BA105
BA217-JACAX- D

350A
BA213-JACAX-

BA211-JACAX-
BA215-JACAX-
BA112-JABAX-350A
TP 350A
02

300A

300A

300A
300A
350x400

TP
350x400

05
LS SACRIFICE FLANGE
A.P.TK
A

BA403-JAFAX-250A

BA401-JAFAX-250A
BA405-JAFAX-250A
V1-01
NOTE 3 NO.6 NO.4 NO.2
NO.5 NO.1
BWN03

NO.7 NO.3 C/H


C/H C/H C/H C/H
TP C/H C/H (P.F)
(P.F) (F)
08
MBL-10 DN350

DN50
TO TROS

BA215 BA214
DN50 NO.4 W.B.TK. CORRESPONDING
NO.6 NO.5
FROM BIS (S) NO.3 W.B.TK. NO.2 W.B.TK. PIPE (250A)
DN50 H.F.O.TK.(S) H.F.O.TK.(S) NO.1 W.B.TK.
TO TROS BA602 (S) (S) (S)

(10K)
DN50 JACAX-400A
TO G2S VOID (S)

C STATIONARY BA601 ON MAIN DECK C


HAND PUMP JASBL-400A CORRESPONDING CORRESPONDING
TP
DN400

DN50 PIPE (250A) TRUNK


09 FROM TROR IN W.B.TK
(TYPICAL)
DN50
FROM TROR
H

BA119 MBL-09 DN150


C (Next Page)
(10K-350A) TYPICAL SECTION
BWN13 BWN14
BA110
MBL-03

WATER BALLAST OVERBOARD -JASBL TYPICAL ''A''


-350A NOTE 3
BELOW LIGHT BALLAST WATER LINE

15
V1-03
LS STPG370 SMLS
BWN01

LS
16.0T (400A)
FM-1-A ELECTROLYTIC CELL
DN50
DN100

350x400 350x400 V3-02 (C-1-A)


NOTE 3 NOTE 3 V3-01 MAIN DECK
S
MBL-01

NOTE 3 NOTE 3
ABT.1.3M
PRV-1-A
TO TROS

DN400
Spool for future NOTE 3
installation of (10K 400A)

ABT 2MM
W.B.TK(P) W.B.TK(S)
SMD-1-A
Vacuum Relief Valve NO.4 C/H OVERFLOW PIPE
NOTE 3
B DN15 B
DN80
FROM DRAIN TANK STPG370 ERW 12.7T(400A)

SIDE SHELL
MBL-02
INSIDE

SLEEVE
WELDING
MBL-08 DN150 INTER-CONNECTION PIPE CARGO HOLD
B (Next Page) STPG370 SMLS 16.0T(250A)
NOTE 3
BWN10 BWN11 BWN12 ARRANGED IN C/HOLD
SET TO 5bar SLEEVE JOIN
MBL-01 DN400 FILTER
F-1-A
V1-02 BWN02
NOTE 3
SWP1 LOWER STOOL
NOTE 3
V5-01-A

MBL-06 MBL-07 H H
D (Next Page)
DN65 DN65
BWN07 65x50 65X32 BWN08 V6-01 BWN09
NOTE 3 NOTE 3
MBL-04
DN80

400A 400A
SP-1-A W.B.TK(P) W.B.TK(S)
MBL-05
DN80
BWN06 BWN05 80x40 80x65 BWN04
NOTE 3
A A
DE-BALLASTING BY GRAVITY SHEET No. PAPER SIZE
[BA119 & BA120] 18/19 A2
DATE REV. No. DRAWING No. SCALE
04/03/2022 -- 21468-P-PD-01 N/A

8 7 6 5 4 3 2 1
6 5 4 3 2 1
LEGEND:

PRELIMINARY
DENOTES EXISTING LINE
DENOTES NEW LINE

TP TIE-IN POINT

(125A)
WDE16
D IN ENGINE D
CASING UPPER DECK
WD032-JABBX-50A

WDE15

WD091-JABBX-80A
ENGINE WD132-JABBX-50A
WDE14
ROOM WD036-JABBX-50A 1ST P.F DECK
WDE13
WD014 WD035-JABBX-50A
HOLD BILGE
EDUCTOR WDE12
WD033-JABBX-50A 2ND P.F DECK
BSE06
S/G RM. (65A) WDE17 WDE11
(80A)
WD130-JABBX-50A
TP TP
C WDE10 C
WD107 WD106 N.C. 15 14
BG203 WD039-JABBX-125A WD131-JABBX-50A FLOOR
TO BILGE OVBD H MBL-12 DN250 (250A)
WD015

BG104-JACBX-250A
OIL COOLER DA700M001-23

DN50
DN50
DN50
DN50
FOR DK MACH. 10K
(10K-200A)
L.O
WDE09 BG102 WDE07 WDE08 BG101 WDE06

WD045-JABBX-200A
TO TROS
E/R

TO TROS
TO G2S

FROM BIS
* PT * PI
PI * PT *
* PI
! *
! PI

! !
NO.2 BILGE, FIRE & NO.1
* PT * CP
G/S PUMPs CP * PT *
D (Previous Page)

* CP
! (90/250 M3/H ! CP *
C (Previous Page)

! X 75/25 mTH) !
B B
B (Previous Page)
SACRIFACE FLANGE

BG045 BG044
(250A) (250A) (250A) (250A)
MBL-06

(10K,200A)

(10K,200A)
DN65

WDE02
WDE03

BG042
BG043
WDE05

WDE04

N.C
N.C
MBL-08
DN150

TP
MBL-09

L.O
DN150

(5K,200A)
13

(5K,200A)
SEE PAGE 10/29

WD030-JABBX-200A FROM CARGO HOLD BILGE MAIN LINE


WDE01
(150A)

BWN15
S.W.CROSS MAIN IN E/R
TP
A.P.TK 12

A A
DE-BALLASTING BY GRAVITY SHEET No. PAPER SIZE
[BA119 & BA120] 19/19 A3
DATE REV. No. DRAWING No. SCALE
04/03/2022 -- 21468-P-PD-01 N/A

6 5 4 3 2 1