This document is an invoice containing line items for equipment, installation, and commissioning of air conditioning systems. It includes items such as ductable split air conditioner units, refrigerant piping, electrical work, ducting, insulation, and partition walls. The total amount due is Rs. 21,33,997.60.
This document is an invoice containing line items for equipment, installation, and commissioning of air conditioning systems. It includes items such as ductable split air conditioner units, refrigerant piping, electrical work, ducting, insulation, and partition walls. The total amount due is Rs. 21,33,997.60.
This document is an invoice containing line items for equipment, installation, and commissioning of air conditioning systems. It includes items such as ductable split air conditioner units, refrigerant piping, electrical work, ducting, insulation, and partition walls. The total amount due is Rs. 21,33,997.60.
od209235/2020_2021 : Supply of ceiling suspended air
cooled ductable split air-conditioners each complete with BLDC Motors for indoor unit, Inverter scroll compressor, air cooled condenser with black fin coating and epoxy coating all the coatings to be covered under manufacture warranty, GSS casing, filters, cooling coils, R410 A refrigernet DC fan motors, corded remote with fan speed and ESP setting Electronic expansion valve refrigerant controls and accessories complete for following unit. The 1.01 4 Nos 274314 1097256 unit shall deliver the rated capacity at AHRI conditions and work even at 50 deg C ambient temperature without tripping. The unit shall be suitable to work on 400V+/- 10%,3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5<br><br>11 TR, 4400 CFM HIGH STATIC INVERTER DUCTABLE SPLIT UNIT
2 LOW SIDE - PART B
od209236/2020_2021 : Installation, testing, and
2.01 commissioning of 11 TR High static Ductable Air 4 Nos 12892 51568 conditioner
od209237/2020_2021 : Supply installation testing and
commissioning including vaccumization and nitrogen testing of Hard drawn copper refrigerant piping interconnecting evaporator and condensing units, complete with all fittings, duly insuated with antimicrobial class O closed cell elastomeric nitrile 2.02 26 RM 2063 162840 rubber tubular sleeve of 19mm thickness for suction and discharge line. Density of insulation material shall be 40 to 55 kg/m3 and thermal conductivity shall not exceed 0.035 w/(m.K.) Refrigerant pipe size should be selected as per equipment manufacturer's recommendations.
od209238/2020_2021 : Supply, installation and testing of
uPVC sch.40 condensate drain piping with thermal 2.03 20 RM 240 19908 insulation of 9mm thick class O anti-microbial nitrile rubber
od209239/2020_2021 : Electrical control
2.04 cabling<br>Control wiring between indoor and 42 RM 474 19908 outdoor units with copper/ aluminium cabling.
od209240/2020_2021 : <br>Supply of MS support
2.05 4 Nos 18509 74036 stand for 11 TR Outdoor units with proper clamping
16.15 : Suppluying and Fixing of powder costed extruded
2.06 aluminium Supply Air Grills with aluminium volume 3.5 sqm 11399 39896.5 control dampers as per specifications. od333516/2020_2021 : Supply installation testing and 2.07 commissioning of Fresh Air louvers with bird screen with 0.5 sqm 16148 8074 VCD.
od209241/2020_2021 : Supply of Support stand for
2.08 4 nos 12417 49668 indoor units & duct of MS with proper clamping od209242/2020_2021 : Supply, installation, testing and commissioning of GSS rectangular duct as per drawings. complete with all fittings such as tee bends, special off- chutes, turning vanes, splitter, dampers, indoors, 2.09 214 sqm 1124 240536 transformation pieces etc. as reqd. as per IS 655 including suspension and supporting arrangement for plenums, ducts, complete as reqd. and as per specs.(only hitech supports shall be used). Thickness - 24 Gauge
2.1 od209243/2020_2021 : GSS DuctingCanvas Connection 4 nos 1628 6512
& commissioning of 9mm thick duly laminated aluminium foil of mat finish closed cell anti-microbial Nitrile rubber (Class "O") insulation on existing duct after applying suitable adhesive for Nitrile 2.11 rubber.The joints shall be sealed with 50mm wide and 155.5 sqm 545 84747.5 3mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required. Density of insulation material shall be between 40 to 55 Kg/m3 and and thermal conductivity shall not exceed 0.035 w/(m.K. )
& commissioning of 10mm thick, Class 1 rated open cell anti-microbial Nitrile rubber for acoustic insulation of ducts using suitable adhesive as per the 2.12 60 sqm 972 58320 recommendation of the insulation manufacturer. Density of insulation material shall be between 140 to 180 Kg/m3 and and thermal conductivity shall not exceed 0.047 w/(m.K.)
od209246/2020_2021 : Additional Refrigerant gas
2.13 5.4 kg 984 5313.6 R410A
3 PARTITION WORKS
od210050/2020_2021 : Double Skin Aluminium Panel
Partition :<br>Providing and fixing in position factory made sandwich panels made of light weight insulated sandwiched panel of 0.5 mm thickness for 3.01 37 sqm 5822 215414 aluminium sheets. Injected polyurethene foam of 50mm thickness and 40 kg/m3 density to be sandwiched between composite panels with necessary supports, accessories required to support the panels rigidly