You are on page 1of 2

Conquer Cooling Solution Pvt Ltd

Authorised Business Dealer


#216/2, Plot : 3, First Floor, Nagawarapalya,
C V Raman Nagar, Bangalore - 560 093

Reference Num : CCS/sales/2016-17/04/006 24.05.2017

BOQ of VRF Proposal Electronicity 183


SUPPLY INSTALLATION SUPPLY INSTALLATION
Sl. no. DESCRIPTION UNIT QTY
RATE RATE AMOUNT AMOUNT

HIGH SIDE AIR CONDITIONING WORKS

A VRF SYSTEM

Supply, installation, testing and commissioning of Variable Refrigerant Flow


Modular type air-conditioning system with wide range of indoor and
outdoor units, with longer actual and total piping length and with high
external static pressure. The system consists of multiple indoor units ranging
from high wall, fan coil, ducted type, cassette type etc. Connected to a single
or multiple modular type outdoor units with individual controllers to each
indoor unit, refrigerant piping, control cabling and also centralized
controller. The specifications and details are as

1 OUTDOOR UNITS

Modular type Top/Side discharge outdoor units equipped with high efficient
scroll compressors, with all inverter type compressors, special acryl pre-
coated heat exchanger having high efficiency E-pass coil design, low noise
condenser fan coupled with variable speed motor, auto check-function for
connection error, auto addressing Including required no. of multi connection
piping kit. Refrigerant Gas should be eco friendly
R410a

a 24 HP(12HP+12HP) - IVRFB-12TC - Out door unit Nos. 2 289957 30000 579914 60000

2 INDOOR UNITS

Supply, Installation, Testing and commissioning of WALL MOUNTED Type


indoor unit with direct driven fan coupled with DC fan motor, 3 step speed
control, applicable for middle and high external static pressure, in built
electronic expansion valve, in built drain pump, washable filter, low
operation sound level and thermal protector for fan motor. Unit should have
2.1 a Maximum height of 500 mm for easy false ceiling installation as

INDOOR UNITS

a 1TR - Indoor Unit (Wall Mounted) VHW12 Nos. 5 16500 1200 82500 6000

b 1.3TR - Indoor Unit (Wall Mounted) VHW16 Nos. 9 17,600 1200 158400 10800

c 1.5 TR - Indoor Unit (Wall Mounted) VHW18 Nos. 3 18,900 1800 56700 5400

d 1.7 TR - Indoor Unit (Wall Mounted) VHW20 Nos. 1 21000 2,500 21000 2500
Corded remote controllers Nos 18 950 110 17100 1980
3 DX - SPLIT SYSTEM
Supply, Installation, Testing and Commissioning of customised / factory
made Hi-Wall Type split package units complete with blower cooling coil
etc., along with matching air cooled condenser with scroll/rotary compressor
all in with microprocessor control including gas charging, Supports for
4 outdoor units,Steblizer, Safety controls, cabling between indoor and
outdoor units with suitable cable trays / Conduide, Refrigeration Controls like
thermostatic Expansion valve, drier

C LOW SIDE AIR CONDITIONING WORKS

Pressure testing, testing, commissioning and handing over of total VRF


5 system. Lot 1 48000 0 48000

6 VRF Refrigerant Piping


Supply, installation , testing & commissioning of copper piping with necessay
fittings and Supports. Interconnecting copper refrigerant pipe work duly
insulated with elastomeric nitrile rubber type tubular insulation between
indoor & outdoor units as per specifications . All piping inside the room shall
be properly supported with hanger and all external piping shall be properly
roughted with clamps and with additional topping up of R410A

c 28.6mm OD (insulation =19 mm thick) Rmt 17 980 200 16660 3400

d 22.2mm OD (insulation =13 mm thick) Rmt 22 860 200 18920 4400


e 19.1mm OD (insulation =13 mm thick) Rmt 19 485 200 9215 3800

f 15.9mm OD (insulation =13 mm thick) Rmt 32 450 200 14400 6400

g 12.7mm OD (insulation =13 mm thick) Rmt 111 385 175 42735 19425

h 9.5mm OD (insulation =13 mm thick) Rmt 18 310 175 5580 3150

i 6.4mm OD (insulation =13 mm thick) Rmt 75 210 150 15750 11250

Supply, installation , testing & commissioning of Y- joints and


7 Refnet joints for branching of refrigerant Nos 17 3400 550 57800 9350

Supply & laying of control cum transmission cable with conduit, cabling
b between Indoor and outdoor units in PVC conduit (2 core Rmt 370 170 50 62900 18500
1.5 sq.mm)

8 Drain Piping

Supply, Installation and testing of UPVC piping complete with fittings,


supports as per specifications and insulated with 9 mm thick nitrile insulation
with protective coating etc., complete as
per technical specifications.

a 20 mm dia Rmt 105 120 50 12600 5250

9 MS Stand- Fabrication for the ODU

Supply, Fabrication, installation of MS Stand for the ODU


supplied
MS fabicated stand
a Nos 2 6,500 500 13000 1000
Towards Transport Charges
10 Lot 1 15000 15000

SUB TOTAL 1200174 220605

Vat @ 14.5% 174025.23 -

Service TAX @ 15% - 33090.75


GRAND TOTAL ( Inclusive of all taxes) 1627894.98

Terms & Conditions


1. 100% payment in advance for the AC Units to be supplied, on the confirmation of the order and along with the PO
2. For Lowside : Based on the site at actuals the final invoice shall be generated / Measurement sheet need to be signed
3. Payment should be made in favour of " Conquer Cooling Solution Pvt Ltd"
4. Above price is inclusive of all taxes
5. Additional supply of gas would be at extra cost
6. Additional Requirements like prefreted Sheet,Drain Pump and others cost according to the site requirement, this would be added against the final invoice
7. The quote for lowside would be provided post the visit and inspection of the site condition.
8. Lowside Part – Installation, Testing, Commissioning, Air-Distribution Quote will be shared once the site condition shared
9. For the 1st Complete – 1 year, the AC Units would be at “WARRANTY” service. In which we would be providing you the 4 complete services at “FREE OF COST”. This is again comes
under the terms and conditions which are explained in brief manner in the “HANDING OVER REPORT”
10. Any spares if found to be at fault during the “WARRANTY PERIOD” would be replaced at free of cost as per the terms mentioned in the Handing over Report.
11. Lowside would be carried out as per the ITEM DESCRIPTION in the BOQ, once we decide about the lowside offer, as soon as
we decide the unit selection process.
12. Electricity – Incoming power supply to be provided while carrying out the project.
13. SAFETY will be followed at NO COMPROMISE factor.
14. Post the lowside offer, if any spares or materials is consumed extra, which would be added against the final invoice while submission. Wherein measurement sheet would be
considered according to the usage.

Thanks & Regards


Mr. Salman Khan
Sales Engineer - Air Conditioning Systems
Mob : 8892394395 / 7760981063
Conquer Cooling Solution Pvt Ltd