SECTION 1-1 QUALITY STANDARD WITH RESPECT TO PHYSICAL PROPERTIES OF ELASTOMER

(SCALE 1 : 10)
a PHYSICAL PROPERTIES UNIT STANDARD VALUE NAME OF TEST AND REFERRED STANDARD
r r
Mpa Low displacement tensile
(1) Static shear modulus 0.80 ± 0.10 JIS:K6254

to
test
-

Tb
(2) Hardness A50 ± 5 Hardness test ISO 7619-1

tu
(3) Elongation (%) 400 or more Tensile test IRC:83 (Part II)
ns ts (mm) ni ti (mm)
ISO 1817
BEARING PLAN SECTION 2-2 (4) Oil resistance properties
(%) +120 or less Oil resistance test
Oil:IRM903(ASTM D471)
(Scale 1 : 10) (Scale 1 : 10) (Rate of volume change) Temperature (°C) : 100
2 Duration (h) : 72
-
Rate of stress change (%) -10 to + 100 ISO 188
(5) Ageing
at 25% elongation

r
resistance Ageing test Temperature (°C) : 100
properties Elongation change (%) -50 or more Duration (h) : 72
rate
IRC:83 (Part II)
Permanent compressive Temperature (°C) : 100
(6) Permanent compressive strain rate (%) 35 or less
strain test
Duration (h) : 24
IRC:83 (Part II)
Ozone concentration
(7) Ozone resistance properties No cracking detected by visual Resistance to ozone (pphm) : 100

b
- observation cracking - static strain test Strain (%) : 30
1 Temperature (°C) : 40±1
- Duration (h) : 96
Rubber Adhesion to Steel Adhesion test
N/mm 7 or more ISO:813
Peel Strength (N per mm of width)

NOTES:

r
tu to - Reinforcing steel plate must be follow IS 2062, Grade E350 B0
a Tb Fy ≥ 350 MPa, Fu ≥ 490 Mpa, δ ≥ 22%.

NAME SIGN DATE PROJECT INFORMATION DRAWING DETAIL

VINH HUNG TRADING CONSULTING AND CONSTRUCTION JSC DRAWN BY NGUYÔN TRäNG TUY£N 29/08/2022
Mumbai-Ahmedabad
DRAWING NAME
ELASTOMERIC BEARING - VSR
ADDRESS: LOT BT2,NO.49,BAc Linh DAm,HOANG LIET WARD,HOANG MAI DISTRICT,HA NOI CITY,ViET NAM. CHECKED BY PH¹M §øC HUY 29/08/2022 High Speed Rail Project
44mm Thick
R
(Package No.MAHSR-C-7)
APPROVED TRAN VAN PHONG 29/08/2022 SCALE: AS DRAWING code: XNK29-DW-V1 DW. NO: 01/03 29/08/2022 DRAFT