Professional Documents
Culture Documents
OBJECTIVE:
A Challenging Career in Basic & Detail Engineering and Project Management of Electrical Design.
BACKGROUND:
More than 15+ years of experience in the Basic & Detail Design Engineering of Electrical System & Electrical
Equipment installations in one of the Largest Refinery in the World – Jamnagar (Reliance Industries Ltd.).
Proven track record in Engineering Design of HV/LV Electrical systems in Continuous Process Refinery,
Petrochemical complexes & Infrastructure Projects. I have executed various Mega scale projects in the capacity of
Design Engineer, Senior Design Engineer & Lead Electrical Design Engineer and presently working as Lead
Electrical Design Engineer (DGM) from the grass root levels, encompassing following activities:
TECHNICAL SKILLS:
Familiarization with International Engineering Codes & Standards, Indian Standard (IS), IEC, IEEE, OISD, CEA
Regulation, SHELL DEPs, Project Specifications and other Electrical operating philosophies.
Developing & Reviewing of Project Design Basis, Project Specifications, and Guideline/Calculations along with
reputed consultant.
Involved in preparation & review of Main Key Single Line Diagram (SLD), Protection SLD (HV & LV distribution)
from voltage level 220kV to 415V for Main Receiving Substation at Captive Power Plant and Main Substation &
Satellite Substations at Process Plant area.
Exposure in several Power System Studies i.e. Short Circuit Study, Load Flow, Motor Start-up, Arc Flash and Power
System Protection Co-ordination from 33kV to 415V Power System on engineering software like, ETAP Power Tools.
Performed the Protection Settings for Grid Transformer Overloading Shedding and implement in EDMS system.
Expertise in preparation & review of Material Requisition(MR)/Data Sheet for Electrical Equipment i.e. Power &
Distribution Transformers, HV & LV Bus Duct, HV & LV Motors, HV & LV Switchgears, AC UPS systems, DC UPS
Systems, package items i.e. Electrical Heat Tracing etc.
Expertise in preparation & review of Sizing calculations for Cables, Transformers, AC & DC UPS System, DC Load
Profile, Battery, Cable Raceways, Earthing and Lightening systems.
Developed a Cable sizing calculation template for 6.6kV & 415V level loads i.e. Motor loads & Non Motor loads.
Expertise in preparation & review of Electrical Substation Building Layouts with compliance latest Codes & Standards.
Review of Hazardous Area classification layouts and Selection of equipment based on Hazardous Area classification
layout.
Involved in review of the conceptualization modeling of Cable trays/Cable Trenches/Equipment modeling and Clash
checks etc. in 3D design environment (PDS using EE Raceway).
Review & Approval on Lighting, Earthing and lightening protection layouts for OSBL & ISBL Process area.
Review of Preliminary estimated bulk MTO, SOQ and detail design MTOs.
Developing logics, schematics for interface with Electrical Controls and Instrumentation.
Page 1 of 3
Extensively worked in multi-discipline project environment interfacing with other disciplines, with regular interface
with construction personnel to resolve Site queries.
Participation in Bidder technical offer review, Technical Bid Evaluation and Vendor documents review, FAT,
Engineering Clearance & Project PO closeout.
Discussion & Close coordination with Project Management Team & Client.
Resolution of Site commissioning queries.
EXPERIENCE:
PROJECTS UNDERTAKEN:
From June-2007 To December-2009 as Design Engineer (Manager);
Detail Engineering for Mega Scale Project for SEZ-Crude, VGO, Aromatics & KHT-CNHT Complex against
JAMNAGAR EXPORT REFINERY PROJECT (SEZ).
Detail Engineering for New Tail Gas Compressor (TGC) 2.5 MW IN SEZ-Aromatics Complex against JERP.
Involved in Const. & Commissioning activities of Electrical Equipment and Elect. System in SEZ-Crude & VGO
Complex against JERP Project.
Basic & Detail Engineering for DTA & SEZ FGC Medium size Project at FCC Complex.
Detail Engineering of DTA Modification-SPENT CAUSTIC in DTA Utility Complex.
Detail Engineering of DTA- EOU-FLEX AND RJ CRUDE in DTA RTF & Crude Complex.
Detail Engineering for implementation of Re-acceleration scheme in MV & LV Switchgear for MV & LV motors.
From Feburay-2020 To Till Date as Lead Electrical Design Engineer (Dy. General Manager):
Basic & Detail Engineering for DTA & SEZ FEED Flexibility Medium size Project at FCC Complex.
Page 2 of 3
Basic & Detail Engineering for Prefabricated Substation (E-House) and Coordination with vendor for E-House
Electrical Engineering and interdisciplinary coordination.
Detail Engineering for modification & up gradation project in PX4 complex at J3 Complex area.
Basic design calculation & revisit the settings for Under frequency load shedding scheme in DTA Complex at MRS
level.
Basic & Detail Engineering for SEZ Crude -3 & 4 DBN Medium size Project.
Basic & Detail Engineering for DTA, SEZ & J3 Complex modification Engineering through MOCs/PIOs and Medium
size project.
Obsolescence Management & Electrical System Reliability related engineering with coordination with OEM vendor in
existing DTA & JERP Complex.
EDUCATION:
Bachelor of Engineering (Electrical) 2002-2006 with 68% from Govt. Engineering College, Jabalpur (M.P.) in R.G.P.V
University Bhopal (M.P.) INDIA.
12th class 2000-2001 with 74.4% from M.P. Board, Satna (M.P.)
10th class 1998-1999 with 76.6% from M.P. Board, Satna (M.P.)
SOFTWARE SKILLS:
ETAP (Power System Study & Calculation)
AGI 32 (Lighting Calculation)
DIGSI-SIEMENS
EE RACEWAY MODELLING (PDS)
SMART PLANT REVIEW (SPR)
RCRA /SETROUTE
MS OFFICE
KEY SKILLS:
Good communication and presentation skills
Integrity and discipline
Interpersonal skills
Teamwork
Leadership
Resource Planning, Scheduling & Time Management
Initiative and Innovativeness
Value Engineering Vision
Quality oriented
Cost oriented
LANGUAGES:
English, Hindi
PERSONAL SUMMARY:
PERMANENT ADDRESS: S/o Mr. Ram Prasad Patel, Near City Kotwali, Behind Gujarati School, Janakpuri, Satna (M.P.)
MARITAL STATUS : MARRIED
DATE OF BIRTH : 08-06-1984
NATIONALITY : INDIAN
DECLARATION:
I hereby affirm that the information in this document is accurate & true to the best of my knowledge.
Page 3 of 3