You are on page 1of 56

Design Notes for Structural Analysis

Project Name Proposed Petro Gazz Apopong

Location Apopong, General Santos City


Owner PETRO GAZZ VENTURES PHILS. CORP., represented by Bernie A. Llena

A. Software/s Used

1. STAAD Pro V8i SS6


2. MIDAS Design+ 2021

B. Reference Codes

1. National Structural Code of the Philippines


2. American Institute for Steel Construction (AISC-05) with Supplementary Seismic Provisions
3. American Concrete Institute (ACI 318-14M)
4. American Society of Civil Engineers (ASCE/SEI 7-10)

C. Loadings Specifications and Provisions

C.1. Dead Loads


Loading Value Unit
Concrete 23.54 kN/cu.m.
Steel 76.93 kN/cu.m.
Mechanical, Electrical, Plumbing Utilities 0.10 kN/sq.m.
Self-Weight of Truss (includes Purlins, Ceiling, MEPF and Roofing) 1.00 kN/sq.m.
Floor Finishes 1.10 kPa
Partition Load 1.00 kPa
100mm thk. CHB 2.98 kPa
Gasoline 6.67 kN/cu.m.
Kerosene 7.90 kN/cu.m.

C.2. Live/Occupancy Loads


Loading Value Unit
Access Floor System 2.40 kN/sq.m.
Roof Live Load 1.00 kN/sq.m.
Construction Live Load 0.50 kN/sq.m.
Storage 6.00 kN/sq.m.

C.3. Wind Provisions


Basic Wind Speed 250 kph
Importance Factor 1.0
Exposure Category B
Building Classification Category Category IV
Structure Type Building Structure
Building Height 5.30 m
Enclosure Classification Open Building

C.4. Seismic Provisions


Occupancy Category Category III
Seismic Zone 0.4
Importance Factor 1.0
Ductility Factor 8.0
Soil Profile Type 4
Distance to the Nearest Fault Line (*Faultfinder, 2019 ) 13.80 km
Specified Fault Line Daguma Fault
Near Source Factor, Na 1.0
Near Source Factor, Nv 1.1
Ct Value 0.0853
Design Notes for Structural Analysis
Project Name Proposed Petro Gazz Apopong

Location Apopong, General Santos City


Owner PETRO GAZZ VENTURES PHILS. CORP., represented by Bernie A. Llena

D. Design Stresses
Materials Value Unit
Concrete
Compressive Strength @ 28 days 20.7 MPa
Reinforcing Bars
For bars 16mm. diameter and greater 275 MPa
For bars less than 16mm. diameter 230 MPa
Structural Steel (ASTM-A36)
For trusses, bracings, and struts 248 MPa
Structural Steel (ASTM-A36)
Cold formed light gauge shapes 248 MPa
Masonry Units
Non-Load Bearing CHB Walls 3.45 MPa
Load Bearing CHB Walls 6.89 MPa

E. Provisions on Foundations

Assume soil bearing capacity of 95 kPa x 1.33 ( wind or seismic load ) = 126.35 kPa
1. In case the actual location of the structure is less than the assumed distance from the seismic
source of 13.8 km, notify the structural engineer, bureau of design for proper revision of the design.
Refer to the seismic source map provided in the NSCP or PHIVOLCS Seismic Source Map

2. No footing shall rest on fill.

3. Bottom of footing shall be at least 1.70 meter below natural grade line, unless otherwise
specified.

4. Soil bearing capacity shall be increased by 33% when in combination with wind or seismic loads

F. Seismic Source Map of Site

Distance of Site Location to the Nearest Fault Line


3456 785 9:99;<=>
?@A45B@0 C 96D9 EF9 99 GD8E99
A@@H3B0456I 79>79J:>87K:=:
L-,0M+NO0*+P()**/*Q+,O0+RS+(-T0U+,O0+)PP0PPV0*,+W0PX2,P+/*+,O0+10YP/,0+V/QO,+.)WZ+[W-V+,O0+W0PX2,P+P,),0T+/*+,O/P+W0\-W,+TX0+,-+X\T),0P+/*
,O0+T),)+/*+,O0+]0-S/P^_`+T),)Y)P0a+b-X+V)Z+W0[0W+,-+,O0+W0\-W,+).)/2)Y20+X\-*+P()**/*Q+,O0+RS+(-T0+[-W+,O0+X\T),0T+)PP0PPV0*,+W0PX2,P
'()*+,-+./01+2-(),/-*
I6BIcBAde4f4H3Id4II6IIc605
e4f4H3 4II6IIc605 6gh?4045B@0d403dH6A@cc60345B@0
596 9 96 8989 8869 7::::9 59
969 8   989  8   
Ijk3l  C     9  69969996 989
C  i  4mmn1opqj23rs 98 8  9
tuvwdxqd3jy2d1k C    89
9 9   8  989  ~ 
2z3d3j{|qjd}j|r2 9968    
 €5 999 
    89
9  969 > 8   8996
  
  9
566  99    89~899 8&9~9
C  D89~ hn13 99 66 8   8‚996ƒ6  9
8D  96 8„86 
…&9 988 8   9669 8  
69~9 9  89 6~6&  69 &~ 9     
…&9 †33njrrs 89~
I|y‡3m2pˆr3 …&989
9 99 66 8   8
‚996ƒ6 E 9 8D  96E 8„86 
‰9 8&9~%  69 6  9 8   9  6 ~ 
‰9 8&9~%"  3j2jdjn3dˆ3p{ 6 9 8    6      89~
…9 6  |mŠj23Š 5 9       89 8&9~%  69 6 
89
9 6 9  9   9 69
5 9 9    99 6 9   %8% 9
 9 Ijk3 9 8&9~ 

01234
56689
9 9   9 9  899696  69 9 8 9 8    6
69
 89 9   9 8 6   9   9 9  
6989
9  !   99 996    9 
" 9 9 89
9 9  9 9 9   9999696   9 9 9  6
9#  9889   9 96 
$  % 969    9696  96  9  9  
896   9 &  

8   9  9 8 8Ci ~„86 ‹9


9 ‹ „‹98      96
" &   89
9 9      & 98 <ŒŒ89 86   8" &  96 89
9 996  89 9896
 9    9 8 96  &  i9D6 Ž 9 86   89 686   8
3456 785 9:99;<=>
?@A45B@0 C 96D9 EF9 99 GD8E99
A@@H3B0456I 79>79J:>87K:=:
L-,0M+NO0*+P()**/*Q+,O0+RS+(-T0U+,O0+)PP0PPV0*,+W0PX2,P+/*+,O0+10YP/,0+V/QO,+.)WZ+[W-V+,O0+W0PX2,P+P,),0T+/*+,O/P+W0\-W,+TX0+,-+X\T),0P+/*
,O0+T),)+/*+,O0+]0-S/P^_`+T),)Y)P0a+b-X+V)Z+W0[0W+,-+,O0+W0\-W,+).)/2)Y20+X\-*+P()**/*Q+,O0+RS+(-T0+[-W+,O0+X\T),0T+)PP0PPV0*,+W0PX2,P
'()*+,-+./01+2-(),/-*
c@?A40BAde4f4H3Id4II6IIg605
e4f4H3 4II6IIg605 6hi?4045B@0d403dH6A@gg60345B@0
j9  5 4llm 1nopq23rs 569 9 8 89  88  96 F8869 8::
k69 tuvwdxpdy1z2{ 9 G5 8      98869 7::::
1|dgq2z2zp 9 9  8996  9 96 69   
"9    8 99 9 8966  8
96 9  96   98 C 966
5 8966 im1}3 9 8966 89 9 899 8  69 9 8
  

01234
56689
9 9   9 9  899696  69 9 8 9 8    6
69
 89 9   9 8 6   9   9 9  
6989
9  !   99 996    9 
" 9 9 89
9 9  9 9 9   9999696   9 9 9  6
9#  9889   9 96 
$  % 969    9696  96  9  9  
896   9 &  

~8   9  9 8 8C €86 ‚9


9 ‚ ‚9~8      96
" &   89
9 9      & 98 <ƒƒ89 86   8" &  96 89
9 996  89 9896
 9    9 8 96  & „ 9„D6 … 9 †86   89 6†86   8
>?@A )B5 C+CCD*EF
GHI?@JH0 ( 96/9 1K9 99 L/8199
IHHM>J0?@AN )CF)CO+FB)P+E+
Q87;R6ST;56U3455:5V67T;6WX638Y;Z67T;64UU;UU[;576\;U]=7U6:567T;6<;^U:7;6[:VT7694\_6̀\8[67T;6\;U]=7U6U747;Y6:567T:U6\;a8\76Y];6786]aY47;U6:5
7T;6Y4746:567T;6b;8X:Ucde6Y474^4U;f6g8]6[4_6\;`;\67867T;6\;a8\76494:=4^=;6]a856U3455:5V67T;6WX638Y;6̀8\67T;6]aY47;Y64UU;UU[;576\;U]=7U
234567869:;<6=8347:85
hi>MHjkA@AHMHGHlJI?Gmh?n?M>Nm?NNANNkA0@
h?n?M> ?NNANNkA0@ AopG?0?@JH0m?0>mMAIHkkA0>?@JH0
5 9 86   6 9%  69 6  9 6 6
9 9 8  69 6  
"699  999   9    9 
 # 9 -(6 96     
,9%"  G1qmNrst3u2vwvxv2yzm01 69 6 %  69 9 $8 6     %   
-9 6  v{3|2v}v3{mx~|{sxv{3s 9  96 9€ 6 96 6 
'   €     89  
 9 6   9  9 6 9   9 9 899 
  96 966  669 6   86   69 6
9    69698  9 € 8'(&

01234
56689
9 9   9 9  899696  69 9 8 9 8    6
69
 89 9   9 8 6   9   9 9  
6989
9  !   99 996    9 
" 9 9 89
9 9  9 9 9   9999696   9 9 9  6
9#  9889   9 96 
$8 68 9%  69 6 9 6     9  &9 8 
9 '(& )*)++++% 96,9%  -9 6 9 .6 / 6'9  9966  
 8
  06 9   9989
9 99 91  9  
.  % 969    9696  96  9  9  
896   9 0  

$8   9  9 8 8(, ‚86 ƒ9


9 ƒ ‚ƒ9$8      96
$9996  696     89      6 0  9„96(89
9 1 9 /" 9
,9%  -9 6 9 .6 89
9  8' 9 (  & 9K'(&L  996 96…8
3456 785 9:99;<=>
?@A45B@0 C 96D9 EF9 99 GD8E99
A@@H3B0456I 79>79J:>87K:=:
L-,0M+NO0*+P()**/*Q+,O0+RS+(-T0U+,O0+)PP0PPV0*,+W0PX2,P+/*+,O0+10YP/,0+V/QO,+.)WZ+[W-V+,O0+W0PX2,P+P,),0T+/*+,O/P+W0\-W,+TX0+,-+X\T),0P+/*
,O0+T),)+/*+,O0+]0-S/P^_`+T),)Y)P0a+b-X+V)Z+W0[0W+,-+,O0+W0\-W,+).)/2)Y20+X\-*+P()**/*Q+,O0+RS+(-T0+[-W+,O0+X\T),0T+)PP0PPV0*,+W0PX2,P
'()*+,-+./01+2-(),/-*
cd3H@ef656@H@?@gBA4?hc4i4H3Ih4II6IIf605
c4i4H3 4II6IIf605 6jk?4045B@0h403hH6A@ff60345B@0
5    Fu 969vG 89 96   96689
    966  u9v"89 89   
 9666 %! 9  9 9  9 6 %6
9 96 
3l2lhlm3hn3opq " 99  89 6%8 99 9    99 
D D  rstl23t 9 69 6   99688 "  
9  88      8988 
$     %  8  9   9 9 7G
8  88 9669G8888  9 KG8
 69 96 %69 9 
…8†96D w ‡9
9 ˆ9    8K%  9‰ 
   9   97:% 88F9  G 9 69
 9…8   9‰986969  89  98
 9 8 9  86  8     
…8†96D w ‡9
9  !     † Š 
F†Š G… 96E6 †   9 8 9 96
8 96‰68 9      †  
9 8 9 69 596‹! 9Š 96 F5‹Š G889 8
89899   89
9 6666&966  !  
xyz{heh||h}s~h€ye3lm 99 
D w m32rmphs3mo1t‚ƒhxyz{he 588     8   9    9 6  &
||h}s~h„yye3lm
m32rmphs3mo1t‚ 56      8   9 6  9  
 &
…8†96   89
9 9 9    98 

98Š86 9 9     6     
$ 8 9 9   9 88  ‰  996 
  Œ 69    66 9     ‰ 
$ 96 9  6 9 9     9 88 96
8   9   9 %     6  
 6 966   9 8   6   

01234
56689
9 9   9 9  899696  69 9 8 9 8    6
69
 89 9   9 8 6   9   9 9  
6989
9  !   99 996    9 
" 9 9 89
9 9  9 9 9   9999696   9 9 9
 69#  9889   9 96 
$  % 969    9696  96  9  9  
896   9 &  
0123567859
3 6 65 969158 16823122772 63  5 965 77012356785923 89853 6
0889 2  822 86 9856 75783635663985 22 6785958916122772 6983716526871!32  3958 82 "65#263
2 2395 928 $  " %!36 2  6 298722 3&7 3 839 8#71

BCDE 35 391211FGH47


IJKCDLJ' 6 65 " 983M29!$, 2 3%"891M89  98
KJJNBL'CDEO 31431P2453Q2H2
R<;?S:TU?9:V7899>9W:;U?:XY:7<Z?[:;U?:8VV?VV\?9;:]?V^A;V:>9:;U?:@?_V>;?:\>WU;:=8]`:a]<\:;U?:]?V^A;V:V;8;?Z:>9:;U>V:]?b<];:Z^?:;<:^bZ8;?V:>9
;U?:Z8;8:>9:;U?:c?<Y>Vdef:Z8;8_8V?g:h<^:\8`:]?a?]:;<:;U?:]?b<];:8=8>A8_A?:^b<9:V7899>9W:;U?:XY:7<Z?:a<]:;U?:^bZ8;?Z:8VV?VV\?9;:]?V^A;V
6789:;<:=>?@:A<78;><9
'ECNEODiKNLDLKCIijCKLILDLEO
KNLDLKCIijCKLILDki'ClE DkmE BLODC'KEijNJliOmEKLjLEBiIJKCDLJ'
n6
"8269!M6 95 03 2066 9 5!"188 3F3
n6
"8269!n 928 2 1"188 2"68  5!"188 HHH
7878 5 6 91o 29 8#65 6 96 91p 229! 345
q2  8q62 M6 965 52# 966 91p 229! QH
q  5rq 56s"891M89  98$2539 52 5!8 n69
85 31
,239529%
659q8558
t#s"891M89  98 "68  5!8 n69
85 3
$2539,239529%
'()*+
1  5 336336 93 56 368 916 # 2 6336792229! 73 9168852 9638916365336696
8 928 
,676 2 8 916 36 7336 69183678!652  772 23567 263 !68365#6
69
66 8 928 81  53856-783562 85 928   9  58 8365# 928 3
. 386 56 31  5 336336 9 !67 96 3 6
 9 686 # 2 6852 9657569 928 85 3 5639
8 /859878 5 7121 636988 3698 95 6#6 93
879 928 3 56 368 916 # 2 66-78356 9  9168852 96389163653366968 928
"1883 9 89 2 658,67 596 980 928 $1234%
6 91 229263 9 89 2 658,67 596 986 91$1235%

0123567859
3 6 65 969158 16823122772 63  5 965 77012356785923 89853 6
Structural Frame

Materials
Mat Name E  Density 
(kN/mm 2) (kg/m3) (/°C)
1 CONCRETE 21.718 0.170 2.4E+3 10E -6
2 ALUMINUM 68.948 0.330 2.71E+3 23E -6
3 STEEL_50_KSI 199.948 0.300 7.83E+3 11.7E -6
4 STAINLESSSTEEL 197.930 0.300 7.83E+3 18E -6
5 STEEL_36_KSI 199.948 0.300 7.83E+3 11.7E -6
6 STEEL_275_NMM2 205.000 0.300 7.85E+3 12E -6
7 STEEL 205.000 0.300 7.83E+3 12E -6
8 STEEL_355_NMM2 205.000 0.300 7.85E+3 12E -6

Section Properties
Prop Section Area Iyy Izz J Material
(cm2) (cm4) (cm4) (cm4)
1 Rect 0.50x0.50 2.5E+3 521E+3 521E+3 879E+3 CONCRETE
2 W12X72 136.129 8.12E+3 24.8E+3 121.956 STEEL
3 W12X30 56.710 844.950 9.91E+3 19.022 STEEL
4 L50X50X3 SD SP 0.01 5.940 30.693 14.299 0.175 STEEL
5 L50X50X3 SD SP 0.01 5.940 30.693 14.299 0.175 STEEL
6 L50X50X3 2.970 11.313 2.991 0.08865 STEEL

Reference Load Cases


Number Name Type

R1 MASS Mass

Primary Load Cases


Number Name Type

1 EQX Seismic
2 EQZ Seismic
3 DL1 Dead
4 LL1 Live
5 WLX Wind
6 WLZ Wind
Combination Load Cases
Comb. Combination L/C Name Primary Primary L/C Name Factor

7 1.0 DL1 + 1.0 LL1 3 DL1 1.00


4 LL1 1.00
8 ULC, 1.4 DEAD 3 DL1 1.40
9 ULC, 1.2 DEAD + 1.6 LIVE 3 DL1 1.20
4 LL1 1.60
10 ULC, 1.2 DEAD + 0.5 LIVE + 0.5 WIND (1) 3 DL1 1.20
4 LL1 0.50
5 WLX 0.50
11 ULC, 1.2 DEAD + 0.5 LIVE + 0.5 WIND (2) 3 DL1 1.20
4 LL1 0.50
6 WLZ 0.50
12 ULC, 1.2 DEAD + 0.5 LIVE + 1 WIND (1) 3 DL1 1.20
4 LL1 0.50
5 WLX 1.00
13 ULC, 1.2 DEAD + 0.5 LIVE + 1 WIND (2) 3 DL1 1.20
4 LL1 0.50
6 WLZ 1.00
14 ULC, 1.2 DEAD + 0.5 LIVE + 1 SEISMIC (1) 3 DL1 1.20
4 LL1 0.50
1 EQX 1.00
15 ULC, 1.2 DEAD + 0.5 LIVE + 1 SEISMIC (2) 3 DL1 1.20
4 LL1 0.50
2 EQZ 1.00
16 ULC, 1.2 DEAD + 0.5 LIVE + -1 SEISMIC (1) 3 DL1 1.20
4 LL1 0.50
1 EQX -1.00
17 ULC, 1.2 DEAD + 0.5 LIVE + -1 SEISMIC (2) 3 DL1 1.20
4 LL1 0.50
2 EQZ -1.00
18 ULC, 0.9 DEAD + 1 WIND (1) 3 DL1 0.90
5 WLX 1.00
19 ULC, 0.9 DEAD + 1 WIND (2) 3 DL1 0.90
6 WLZ 1.00
20 ULC, 0.9 DEAD + 1 SEISMIC (1) 3 DL1 0.90
1 EQX 1.00
21 ULC, 0.9 DEAD + 1 SEISMIC (2) 3 DL1 0.90
2 EQZ 1.00
22 ULC, 0.9 DEAD + -1 SEISMIC (1) 3 DL1 0.90
1 EQX -1.00
23 ULC, 0.9 DEAD + -1 SEISMIC (2) 3 DL1 0.90
2 EQZ -1.00

Beam Maximum Forces by Section Property


Axial Shear Torsion Bending
Section Max Fx Max Fy Max Fz Max Mx Max My Max Mz
(kN) (kN) (kN) (kN-m) (kN-m) (kN-m)
Rect 0.50x0.50 Max +ve 139.590 10.134 11.300 0.009 31.105 53.487
Max -ve -10.134 -11.297 -0.009 -31.110 -53.487
W12X72 Max +ve 138.176 10.116 11.282 0.009 28.845 51.460
Max -ve -10.116 -11.279 -0.009 -28.850 -51.460
W12X30 Max +ve 1.395 38.753 1.670 0.004 5.012 76.407
Max -ve -1.541 -38.753 -1.668 -0.004 -5.018 -35.890
L50X50X3 SD SP 0.01 Max +ve 23.069 1.474 0.481 0.001 0.451 0.180
Max -ve -22.900 -1.470 -0.480 -0.001 -0.449 -0.086
L50X50X3 SD SP 0.01 Max +ve 7.701 0.300 0.435 0.001 0.168 0.169
Max -ve -8.163 -0.289 -0.449 -0.001 -0.168 -0.123
L50X50X3 Max +ve 11.230 0.010 0.002 0.000 0.004 0.000
Max -ve -11.299 -0.010 -0.002 -0.000 -0.003 -0.002
Reaction Summary
Horizontal Vertical Horizontal Moment
Node L/C FX FY FZ MX MY MZ
(kN) (kN) (kN) (kN-m) (kN-m) (kN-m)
Max FX 2 16:ULC, 1.2 DEAD +10.134
0.5 LIVE + -1
94.534
SEISMIC (1)
2.812 5.226 0.009 -53.487
Min FX 2 14:ULC, 1.2 DEAD +-10.134
0.5 LIVE + 194.534
SEISMIC (1)2.814 5.229 -0.009 53.487
Max FY 2 9:ULC, 1.2 DEAD + 1.6
-0.000
LIVE 139.590 4.325 8.037 0.000 -0.000
Min FY 1 21:ULC, 0.9 DEAD + 10.825
SEISMIC 49.641
(2) -10.078 -28.840 -0.005 -4.367
Max FZ 2 17:ULC, 1.2 DEAD + 0.5
0.825
LIVE + -1
88.635
SEISMIC (2)
11.300 31.110 0.005 -4.367
Min FZ 1 15:ULC, 1.2 DEAD + 0.5
0.825
LIVE + 188.635
SEISMIC (2)
-11.297 -31.105 -0.005 -4.367
Max MX 2 17:ULC, 1.2 DEAD + 0.5
0.825
LIVE + -1
88.635
SEISMIC (2)
11.300 31.110 0.005 -4.367
Min MX 1 15:ULC, 1.2 DEAD + 0.5
0.825
LIVE + 188.635
SEISMIC (2)
-11.297 -31.105 -0.005 -4.367
Max MY 1 16:ULC, 1.2 DEAD + 0.5
6.836
LIVE + -1
94.534
SEISMIC (1)
-2.812 -5.226 0.009 -36.026
Min MY 1 20:ULC, 0.9 DEAD + -6.836
1 SEISMIC 55.540
(1) -1.595 -2.964 -0.009 36.026
Max MZ 2 14:ULC, 1.2 DEAD +-10.134
0.5 LIVE + 194.534
SEISMIC (1)2.814 5.229 -0.009 53.487
Min MZ 2 16:ULC, 1.2 DEAD +10.134
0.5 LIVE + -1
94.534
SEISMIC (1)
2.812 5.226 0.009 -53.487

Failed Members
There is no data of this type.
Thursday, 7 July 2022 11:28 AM

PAGE NO. 1

****************************************************
* *
* STAAD.Pro CONNECT Edition *
* Version 22.00.00.15 *
* Proprietary Program of *
* Bentley Systems, Inc. *
* Date= JUL 7, 2022 *
* Time= 10:36:19 *
* *
* Licensed to: only @ ::LAVTeam:: (R) *
****************************************************

1. STAAD SPACE
INPUT FILE: C:\Users\ceoen\Desktop\ONWORK~1\2022­0~1\2022­019 Frame Analysis.STD
2. START JOB INFORMATION
3. ENGINEER DATE 07­JUL­22
4. END JOB INFORMATION
5. INPUT WIDTH 79
6. UNIT METER KN
7. JOINT COORDINATES
8. 1 0 0 0; 2 0 0 6.4; 3 0 0.2 0; 4 0 0.2 6.4; 5 0 5.3 0; 6 0 5.3 6.4
9. 7 0 5.3 3.2; 8 0 5.3 ­3.2; 9 0 5.3 9.6; 10 ­3.2 5.3 0; 11 ­3.2 5.3 6.4
10. 12 ­3.2 5.3 3.2; 13 3.2 5.3 0; 14 3.2 5.3 6.4; 15 3.2 5.3 3.2
11. 16 ­3.2 5.3 ­3.2; 17 ­3.2 5.3 9.6; 18 3.2 5.3 ­3.2; 19 3.2 5.3 9.6
12. 20 ­3.2 4.7 0; 21 ­3.2 4.7 6.4; 22 ­3.2 4.7 3.2; 23 ­3.2 4.7 ­3.2
13. 24 ­3.2 4.7 9.6; 25 ­3.2 4.7 0.64; 26 ­3.2 4.7 1.28; 27 ­3.2 4.7 1.92
14. 28 ­3.2 4.7 2.56; 29 ­3.2 4.7 3.84; 30 ­3.2 4.7 4.48; 31 ­3.2 4.7 5.12
15. 32 ­3.2 4.7 5.76; 33 ­3.2 4.7 ­2.56; 34 ­3.2 4.7 ­1.92; 35 ­3.2 4.7 ­1.28
16. 36 ­3.2 4.7 ­0.64; 37 ­3.2 4.7 7.04; 38 ­3.2 4.7 7.68; 39 ­3.2 4.7 8.32
17. 40 ­3.2 4.7 8.96; 41 ­3.2 5.3 0.64; 42 ­3.2 5.3 1.28; 43 ­3.2 5.3 1.92
18. 44 ­3.2 5.3 2.56; 45 ­3.2 5.3 3.84; 46 ­3.2 5.3 4.48; 47 ­3.2 5.3 5.12
19. 48 ­3.2 5.3 5.76; 49 ­3.2 5.3 ­2.56; 50 ­3.2 5.3 ­1.92; 51 ­3.2 5.3 ­1.28
20. 52 ­3.2 5.3 ­0.64; 53 ­3.2 5.3 7.04; 54 ­3.2 5.3 7.68; 55 ­3.2 5.3 8.32
21. 56 ­3.2 5.3 8.96; 57 0 4.7 ­3.2; 58 3.2 4.7 ­3.2; 59 ­2.56 4.7 ­3.2
22. 60 ­1.92 4.7 ­3.2; 61 ­1.28 4.7 ­3.2; 62 ­0.64 4.7 ­3.2; 63 0.64 4.7 ­3.2
23. 64 1.28 4.7 ­3.2; 65 1.92 4.7 ­3.2; 66 2.56 4.7 ­3.2; 67 ­2.56 5.3 ­3.2
24. 68 ­1.92 5.3 ­3.2; 69 ­1.28 5.3 ­3.2; 70 ­0.64 5.3 ­3.2; 71 0.64 5.3 ­3.2
25. 72 1.28 5.3 ­3.2; 73 1.92 5.3 ­3.2; 74 2.56 5.3 ­3.2; 75 3.2 4.7 0
26. 76 3.2 4.7 6.4; 77 3.2 4.7 3.2; 78 3.2 4.7 9.6; 79 3.2 4.7 0.64
27. 80 3.2 4.7 1.28; 81 3.2 4.7 1.92; 82 3.2 4.7 2.56; 83 3.2 4.7 3.84
28. 84 3.2 4.7 4.48; 85 3.2 4.7 5.12; 86 3.2 4.7 5.76; 87 3.2 4.7 ­2.56
29. 88 3.2 4.7 ­1.92; 89 3.2 4.7 ­1.28; 90 3.2 4.7 ­0.64; 91 3.2 4.7 7.04
30. 92 3.2 4.7 7.68; 93 3.2 4.7 8.32; 94 3.2 4.7 8.96; 95 3.2 5.3 0.64
31. 96 3.2 5.3 1.28; 97 3.2 5.3 1.92; 98 3.2 5.3 2.56; 99 3.2 5.3 3.84
32. 100 3.2 5.3 4.48; 101 3.2 5.3 5.12; 102 3.2 5.3 5.76; 103 3.2 5.3 ­2.56
33. 104 3.2 5.3 ­1.92; 105 3.2 5.3 ­1.28; 106 3.2 5.3 ­0.64; 107 3.2 5.3 7.04
34. 108 3.2 5.3 7.68; 109 3.2 5.3 8.32; 110 3.2 5.3 8.96; 111 0 4.7 9.6
35. 112 ­2.56 4.7 9.6; 113 ­1.92 4.7 9.6; 114 ­1.28 4.7 9.6; 115 ­0.64 4.7 9.6
36. 116 0.64 4.7 9.6; 117 1.28 4.7 9.6; 118 1.92 4.7 9.6; 119 2.56 4.7 9.6
37. 120 ­2.56 5.3 9.6; 121 ­1.92 5.3 9.6; 122 ­1.28 5.3 9.6; 123 ­0.64 5.3 9.6
38. 124 0.64 5.3 9.6; 125 1.28 5.3 9.6; 126 1.92 5.3 9.6; 127 2.56 5.3 9.6

C:\Users\ceoen\Desktop\ONWORK~1\2022­0~1\2022­019 Frame Analysis.anl Page 1 of 518


Thursday, 7 July 2022 11:28 AM

STAAD SPACE ­­ PAGE NO. 2

39. MEMBER INCIDENCES


40. 1 1 3; 2 2 4; 3 3 5; 4 4 6; 5 5 7; 6 7 6; 7 6 9; 8 8 5; 9 10 5; 10 12 7
41. 11 11 6; 12 5 13; 13 6 14; 14 7 15; 15 10 41; 16 12 45; 17 16 49; 18 11 53
42. 19 13 95; 20 15 99; 21 14 107; 22 18 103; 23 16 67; 24 8 71; 25 17 120
43. 26 9 124; 27 20 10; 28 21 11; 29 22 12; 30 23 16; 31 24 17; 32 20 25; 33 22 29
44. 34 23 33; 35 21 37; 36 25 26; 37 26 27; 38 27 28; 39 28 22; 40 29 30; 41 30 31
45. 42 31 32; 43 32 21; 44 33 34; 45 34 35; 46 35 36; 47 36 20; 48 37 38; 49 38 39
46. 50 39 40; 51 40 24; 52 41 42; 53 42 43; 54 43 44; 55 44 12; 56 45 46; 57 46 47
47. 58 47 48; 59 48 11; 60 49 50; 61 50 51; 62 51 52; 63 52 10; 64 53 54; 65 54 55
48. 66 55 56; 67 56 17; 68 33 49; 69 34 50; 70 35 51; 71 36 52; 72 25 41; 73 26 42
49. 74 27 43; 75 28 44; 76 29 45; 77 30 46; 78 31 47; 79 32 48; 80 37 53; 81 38 54
50. 82 39 55; 83 40 56; 84 16 33; 85 49 34; 86 50 35; 87 51 36; 88 52 20; 89 10 25
51. 90 41 26; 91 42 27; 92 43 28; 93 44 22; 94 12 29; 95 45 30; 96 46 31; 97 47 32
52. 98 48 21; 99 11 37; 100 53 38; 101 54 39; 102 55 40; 103 56 24; 104 23 59
53. 105 57 63; 106 57 8; 107 58 18; 108 59 60; 109 60 61; 110 61 62; 111 62 57
54. 112 63 64; 113 64 65; 114 65 66; 115 66 58; 116 67 68; 117 59 67; 118 68 69
55. 119 60 68; 120 69 70; 121 61 69; 122 70 8; 123 62 70; 124 71 72; 125 63 71
56. 126 72 73; 127 64 72; 128 73 74; 129 65 73; 130 74 18; 131 66 74; 132 16 59
57. 133 67 60; 134 68 61; 135 69 62; 136 70 57; 137 8 63; 138 71 64; 139 72 65
58. 140 73 66; 141 74 58; 142 95 96; 143 96 97; 144 97 98; 145 98 15; 146 99 100
59. 147 100 101; 148 101 102; 149 102 14; 150 103 104; 151 104 105; 152 105 106
60. 153 106 13; 154 107 108; 155 108 109; 156 109 110; 157 110 19; 158 75 13
61. 159 76 14; 160 77 15; 161 78 19; 162 75 79; 163 77 83; 164 58 87; 165 76 91
62. 166 79 80; 167 80 81; 168 81 82; 169 82 77; 170 83 84; 171 84 85; 172 85 86
63. 173 86 76; 174 87 88; 175 88 89; 176 89 90; 177 90 75; 178 91 92; 179 92 93
64. 180 93 94; 181 94 78; 182 87 103; 183 88 104; 184 89 105; 185 90 106
65. 186 79 95; 187 80 96; 188 81 97; 189 82 98; 190 83 99; 191 84 100; 192 85 101
66. 193 86 102; 194 91 107; 195 92 108; 196 93 109; 197 94 110; 198 18 87
67. 199 103 88; 200 104 89; 201 105 90; 202 106 75; 203 13 79; 204 95 80
68. 205 96 81; 206 97 82; 207 98 77; 208 15 83; 209 99 84; 210 100 85; 211 101 86
69. 212 102 76; 213 14 91; 214 107 92; 215 108 93; 216 109 94; 217 110 78
70. 218 120 121; 219 121 122; 220 122 123; 221 123 9; 222 124 125; 223 125 126
71. 224 126 127; 225 127 19; 226 24 112; 227 111 116; 228 111 9; 229 112 113
72. 230 113 114; 231 114 115; 232 115 111; 233 116 117; 234 117 118; 235 118 119
73. 236 119 78; 237 112 120; 238 113 121; 239 114 122; 240 115 123; 241 116 124
74. 242 117 125; 243 118 126; 244 119 127; 245 17 112; 246 120 113; 247 121 114
75. 248 122 115; 249 123 111; 250 9 116; 251 124 117; 252 125 118; 253 126 119
76. 254 127 78
77. START GROUP DEFINITION
78. JOINT
79. _F1 1 2
80. MEMBER
81. _PEDESTAL 1 2
82. _C1 3 4
83. _TR1 9 11 TO 13
84. _TR2 7 8 10 14
85. _TR3 5 6
86. FLOOR
87. _LOAD_ROOF 5 TO 26 52 TO 67 116 118 120 122 124 126 128 130 142 TO 157 218 ­
88. 219 TO 225
89. END GROUP DEFINITION
90. DEFINE MATERIAL START
91. ISOTROPIC CONCRETE
92. E 2.17185E+07
93. POISSON 0.17
94. DENSITY 23.5616

C:\Users\ceoen\Desktop\ONWORK~1\2022­0~1\2022­019 Frame Analysis.anl Page 2 of 518


Thursday, 7 July 2022 11:28 AM

STAAD SPACE ­­ PAGE NO. 3

95. ALPHA 1E­05


96. DAMP 0.05
97. TYPE CONCRETE
98. STRENGTH FCU 27579
99. ISOTROPIC STEEL
100. E 2.05E+08
101. POISSON 0.3
102. DENSITY 76.8195
103. ALPHA 1.2E­05
104. DAMP 0.03
105. TYPE STEEL
106. STRENGTH RY 1.5 RT 1.2
107. END DEFINE MATERIAL
108. MEMBER PROPERTY AMERICAN
109. 1 2 PRIS YD 0.5 ZD 0.5
110. MEMBER PROPERTY AMERICAN
111. 3 4 TABLE ST W12X72
112. 5 TO 14 TABLE ST W12X30
113. MEMBER PROPERTY CHINESE
114. 15 TO 26 32 TO 67 104 105 108 TO 116 118 120 122 124 126 128 130 142 TO 157 ­
115. 162 TO 181 218 TO 227 229 TO 236 TABLE SD L50X50X3 SP 0.006
116. 27 TO 31 68 TO 83 106 107 117 119 121 123 125 127 129 131 158 TO 161 ­
117. 182 TO 197 228 237 TO 244 TABLE SD L50X50X3 SP 0.006
118. 84 TO 103 132 TO 141 198 TO 217 245 TO 254 TABLE ST L50X50X3
119. CONSTANTS
120. MATERIAL CONCRETE MEMB 1 2
121. MATERIAL STEEL MEMB 3 TO 254
122. SUPPORTS
123. 1 2 FIXED
124. MEMBER CRACKED
125. 1 2 REDUCTION RIX 0.700000 RIY 0.700000 RIZ 0.700000
126. MEMBER RELEASE
127. 84 TO 103 132 TO 141 198 TO 217 245 TO 254 START MP 0.99
128. 84 TO 103 132 TO 141 198 TO 217 245 TO 254 END MP 0.99
129. DEFINE REFERENCE LOADS
130. LOAD R1 LOADTYPE MASS TITLE MASS
131. SELFWEIGHT Y 1
132. FLOOR LOAD
133. _LOAD_ROOF FLOAD 1.1 GY
134. END DEFINE REFERENCE LOADS

*** NOTE: MASS MODEL FORMED WILL BE USED IN SEISMIC/RESPONSE/TIME HISTORY LOADING, IF ANY.
IF MASS MODEL IS SEPARATELY PROVIDED IN INDIVIDUAL LOADING, THE GENERATED MASS
WILL BE REPLACED BY THE MASS PROVIDED IN INDIVIDUAL LOADING.

135. FLOOR DIAPHRAGM


136. DIA 1 TYPE RIG HEI 5.3 JOINT 5 6
137. CHECK SOFT STORY ASCE7

C:\Users\ceoen\Desktop\ONWORK~1\2022­0~1\2022­019 Frame Analysis.anl Page 3 of 518


Thursday, 7 July 2022 11:28 AM

    STAAD SPACE                                              ­­ PAGE NO.    4

FLOOR DIAPHRAGM

   ************************************************************************************

   FLOOR DIAPHRAGM     UNIT ­ KN   METE
   ­­­­­­­­­­­­­­­     ­­­­­­­­­­­­­­­­

    NO.  TYPE        FL. LEVEL      FL. WT     CENTRE   OF   MASS    MASTER JOINT NO.
                                                  X          Z        

     1   RIGID           5.300         47.49     0.000      3.200                7

   ************************************************************************************

   138. DEFINE WIND LOAD
   139. TYPE 1 WIND
   140. <! STAAD PRO GENERATED DATA DO NOT MODIFY !!!
   141. ASCE­7­2010:PARAMS 150.000 KMPH 0 1 1 0 0.000 FT 0.000 FT 0.000 FT 1 0 5.300 ­
   142. M 6.400 M 12.800 M 2.000 0.010 0 0 0 0 0 0.600 1.000 1.000 0.850 0 0 0 0 ­
   143. 0.869 0.800 0.000
   144. !> END GENERATED DATA BLOCK
   145. INT 0.36148 0.36148 0.36274 0.363988 0.365226 0.366454 0.367671 0.368879 ­
   146. 0.370077 0.371265 0.372443 0.373613 0.374773 0.375924 0.377067 HEIG 0 4.572 ­
   147. 4.628 4.684 4.74 4.796 4.852 4.908 4.964 5.02 5.076 5.132 5.188 5.244 5.3
   148. EXP 1 JOINT 5 TO 127
   149. DEFINE UBC LOAD
   150. ZONE 0.4 I 1 RWX 8 RWZ 8 STYP 4 CT 0.0853 NA 1 NV 1
   151. REFERENCE LOAD Y

   *** NOTE: SEISMIC WEIGHT TABLE IS PRESENT.THIS WEIGHT TABLE 
             WILL BE CONSIDERED IN STATIC SEISMIC ANALYSIS.

   152. R1 1.0
   153. LOAD 1 LOADTYPE SEISMIC  TITLE EQX
   154. UBC LOAD X 1 DEC 1 ACC 0.05
   155. PERFORM ANALYSIS

C:\Users\ceoen\Desktop\ONWORK~1\2022­0~1\2022­019 Frame Analysis.anl Page 4 of 518


Thursday, 7 July 2022 11:28 AM

STAAD SPACE ­­ PAGE NO. 5

P R O B L E M S T A T I S T I C S
­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­

NUMBER OF JOINTS 127 NUMBER OF MEMBERS 254


NUMBER OF PLATES 0 NUMBER OF SOLIDS 0
NUMBER OF SURFACES 0 NUMBER OF SUPPORTS 2

Using 64­bit analysis engine.

SOLVER USED IS THE OUT­OF­CORE BASIC SOLVER

ORIGINAL/FINAL BAND­WIDTH= 115/ 26/ 156 DOF


TOTAL PRIMARY LOAD CASES = 1, TOTAL DEGREES OF FREEDOM = 744
TOTAL LOAD COMBINATION CASES = 0 SO FAR.
SIZE OF STIFFNESS MATRIX = 117 DOUBLE KILO­WORDS
REQRD/AVAIL. DISK SPACE = 13.6/ 75329.6 MB

SOFT STORY CHECK

VERTICAL STRUCTURAL IRREGULARITIES : SOFT STORY CHECK ­ ASCE/SEI 7­05


­­­­­­­­ ­­­­­­­­­­ ­­­­­­­­­­­­­­

STORY FL. LEVEL IN METE S T A T U S


­­­­­ ­­­­­­­­­­­­­­­­­ ­­­­­­­­­­­­­­­­­­­­
X Z

1 5.30 OK OK

NOTE : NO SOFT STOREY IS DETECTED.

***********************************************************
* *
* X DIRECTION : Ta = 0.298 Tb = 0.550 Tuser = 0.000 *
* T = 0.298, LOAD FACTOR = 1.000 *
* UBC TYPE = 97 *
* UBC FACTOR V = 0.1375 x 123.42 = 16.97 KN *
* *
***********************************************************

C:\Users\ceoen\Desktop\ONWORK~1\2022­0~1\2022­019 Frame Analysis.anl Page 5 of 518


Thursday, 7 July 2022 11:28 AM

STAAD SPACE ­­ PAGE NO. 6

************************************************************************

***NOTE: SEISMIC LOAD IS ACTING AT CENTER OF MASS FOR RIGID DIAPHRAGM.


TORSION FROM STATIC ECCENTRICITY (esi) IS INCLUDED IN ANALYSIS.
DYNAMIC ECCENTRICITY APPLIED = DEC ­ 1

LOAD NO.: 1 DIRECTION : X UNIT ­ METE

STORY LEVEL DYN. ECC. (dec) ACC. ECC. (aec) DESIGN ECC.
­­­­­ ­­­­­ ­­­­­­­­­­­­­­­ ­­­­­­­­­­­­­­­ ­­­­­­­­­­­­­­­
X Z X Z X Z
dec + aec dec + aec

1 5.30 0.00 0.00 0.32 0.64 0.00 0.64

************************************************************************

156. CHANGE
157. PRINT STORY DRIFT 0.004500
STORY DRIFT 0.004500

C:\Users\ceoen\Desktop\ONWORK~1\2022­0~1\2022­019 Frame Analysis.anl Page 6 of 518


Thursday, 7 July 2022 11:28 AM

STAAD SPACE ­­ PAGE NO. 7

STORY HEIGHT LOAD AVG. DISP(CM ) DRIFT(CM ) RATIO STATUS


­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­
(METE) X Z X Z

BASE= 0.00 ALLOW. DRIFT = L / 222

1 0.00 1 0.0000 0.0000 0.0000 0.0000 L /999999 PASS

2 5.30 1 0.8056 0.0000 0.8056 0.0000 L / 658 PASS


158. LOAD 2 LOADTYPE SEISMIC TITLE EQZ
159. UBC LOAD Z 1 DEC 1 ACC 0.05
160. PERFORM ANALYSIS

SOFT STORY CHECK

VERTICAL STRUCTURAL IRREGULARITIES : SOFT STORY CHECK ­ ASCE/SEI 7­05


­­­­­­­­ ­­­­­­­­­­ ­­­­­­­­­­­­­­

STORY FL. LEVEL IN METE S T A T U S


­­­­­ ­­­­­­­­­­­­­­­­­ ­­­­­­­­­­­­­­­­­­­­
X Z

1 5.30 OK OK

NOTE : NO SOFT STOREY IS DETECTED.

C:\Users\ceoen\Desktop\ONWORK~1\2022­0~1\2022­019 Frame Analysis.anl Page 7 of 518


Thursday, 7 July 2022 11:28 AM

STAAD SPACE ­­ PAGE NO. 8

***********************************************************
* *
* Z DIRECTION : Ta = 0.298 Tb = 0.567 Tuser = 0.000 *
* T = 0.298, LOAD FACTOR = 1.000 *
* UBC TYPE = 97 *
* UBC FACTOR V = 0.1375 x 123.42 = 16.97 KN *
* *
***********************************************************

************************************************************************

***NOTE: SEISMIC LOAD IS ACTING AT CENTER OF MASS FOR RIGID DIAPHRAGM.


TORSION FROM STATIC ECCENTRICITY (esi) IS INCLUDED IN ANALYSIS.
DYNAMIC ECCENTRICITY APPLIED = DEC ­ 1

LOAD NO.: 2 DIRECTION : Z UNIT ­ METE

STORY LEVEL DYN. ECC. (dec) ACC. ECC. (aec) DESIGN ECC.
­­­­­ ­­­­­ ­­­­­­­­­­­­­­­ ­­­­­­­­­­­­­­­ ­­­­­­­­­­­­­­­
X Z X Z X Z
dec + aec dec + aec

1 5.30 0.00 0.00 0.32 0.64 0.32 0.00

************************************************************************

161. CHANGE
162. PRINT STORY DRIFT 0.004500
STORY DRIFT 0.004500

C:\Users\ceoen\Desktop\ONWORK~1\2022­0~1\2022­019 Frame Analysis.anl Page 8 of 518


Thursday, 7 July 2022 11:28 AM

STAAD SPACE ­­ PAGE NO. 9

STORY HEIGHT LOAD AVG. DISP(CM ) DRIFT(CM ) RATIO STATUS


­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­
(METE) X Z X Z

BASE= 0.00 ALLOW. DRIFT = L / 222

1 0.00 2 0.0000 0.0000 0.8056 0.0000 L /999999 PASS

2 5.30 2 ­0.0000 0.8059 0.0000 0.8059 L / 657 PASS


163. LOAD 3 LOADTYPE DEAD TITLE DL1
164. REFERENCE LOAD
165. R1 ­1.0
166. LOAD 4 LOADTYPE LIVE TITLE LL1
167. FLOOR LOAD
168. _LOAD_ROOF FLOAD ­1 GY
**NOTE** about Floor/OneWay Loads/Weights.
Please note that depending on the shape of the floor you may
have to break up the FLOOR/ONEWAY LOAD into multiple commands.
For details please refer to Technical Reference Manual
Section 5.32.4.2 Note d and/or "5.32.4.3 Note f.

**NOTE** about FLOOR GROUP command


All floor panels in a floor group should lie in a single plane.
If not lying in a single plane break single FLOOR GROUP
command into multiple FLOOR GROUP commands where each
floor group lie in a single plane / height.

169. LOAD 5 LOADTYPE WIND TITLE WLX


170. WIND LOAD X 1 TYPE 1 YR 4.7 5.3
171. LOAD 6 LOADTYPE WIND TITLE WLZ
172. WIND LOAD Z 1 TYPE 1 YR 4.7 5.3

C:\Users\ceoen\Desktop\ONWORK~1\2022­0~1\2022­019 Frame Analysis.anl Page 9 of 518


Thursday, 7 July 2022 11:28 AM

STAAD SPACE ­­ PAGE NO. 10

173. LOAD COMB 7 1.0 DL1 + 1.0 LL1


174. 3 1.0 4 1.0
175. LOAD COMB 8 ULC, 1.4 DEAD
176. 3 1.4
177. LOAD COMB 9 ULC, 1.2 DEAD + 1.6 LIVE
178. 3 1.2 4 1.6
179. LOAD COMB 10 ULC, 1.2 DEAD + 0.5 LIVE + 0.5 WIND (1)
180. 3 1.2 4 0.5 5 0.5
181. LOAD COMB 11 ULC, 1.2 DEAD + 0.5 LIVE + 0.5 WIND (2)
182. 3 1.2 4 0.5 6 0.5
183. LOAD COMB 12 ULC, 1.2 DEAD + 0.5 LIVE + 1 WIND (1)
184. 3 1.2 4 0.5 5 1.0
185. LOAD COMB 13 ULC, 1.2 DEAD + 0.5 LIVE + 1 WIND (2)
186. 3 1.2 4 0.5 6 1.0
187. LOAD COMB 14 ULC, 1.2 DEAD + 0.5 LIVE + 1 SEISMIC (1)
188. 3 1.2 4 0.5 1 1.0
189. LOAD COMB 15 ULC, 1.2 DEAD + 0.5 LIVE + 1 SEISMIC (2)
190. 3 1.2 4 0.5 2 1.0
191. LOAD COMB 16 ULC, 1.2 DEAD + 0.5 LIVE + ­1 SEISMIC (1)
192. 3 1.2 4 0.5 1 ­1.0
193. LOAD COMB 17 ULC, 1.2 DEAD + 0.5 LIVE + ­1 SEISMIC (2)
194. 3 1.2 4 0.5 2 ­1.0
195. LOAD COMB 18 ULC, 0.9 DEAD + 1 WIND (1)
196. 3 0.9 5 1.0
197. LOAD COMB 19 ULC, 0.9 DEAD + 1 WIND (2)
198. 3 0.9 6 1.0
199. LOAD COMB 20 ULC, 0.9 DEAD + 1 SEISMIC (1)
200. 3 0.9 1 1.0
201. LOAD COMB 21 ULC, 0.9 DEAD + 1 SEISMIC (2)
202. 3 0.9 2 1.0
203. LOAD COMB 22 ULC, 0.9 DEAD + ­1 SEISMIC (1)
204. 3 0.9 1 ­1.0
205. LOAD COMB 23 ULC, 0.9 DEAD + ­1 SEISMIC (2)
206. 3 0.9 2 ­1.0
207. PERFORM ANALYSIS

SOFT STORY CHECK

VERTICAL STRUCTURAL IRREGULARITIES : SOFT STORY CHECK ­ ASCE/SEI 7­05


­­­­­­­­ ­­­­­­­­­­ ­­­­­­­­­­­­­­

STORY FL. LEVEL IN METE S T A T U S


­­­­­ ­­­­­­­­­­­­­­­­­ ­­­­­­­­­­­­­­­­­­­­
X Z

1 5.30 OK OK

NOTE : NO SOFT STOREY IS DETECTED.

C:\Users\ceoen\Desktop\ONWORK~1\2022­0~1\2022­019 Frame Analysis.anl Page 10 of 518


Thursday, 7 July 2022 11:28 AM

STAAD SPACE ­­ PAGE NO. 11

208. PRINT DIA CR


DIA CR

************************************************************

CENTRE OF RIGIDITY UNIT ­ METE


­­­­­­­­­­­­­­­­­­ ­­­­­­­­­­­

DIAPHRAM FL. LEVEL X­COORDINATE Z­COORDINATE

1 5.300 0.000 3.200

************************************************************

209. PRINT STORY STIFFNESS


STORY STIFFNES

****************************************************************************

STORY STIFFNESS UNIT ­ METE KN


­­­­­­­­­­­­­­­ ­­­­­­­­­­­­­­­­

DIAPHRAM FL. LEVEL LATERAL­X LATERAL­Z ROTATIONAL­Y

1 5.300 2.093E+03 2.100E+03 2.153E+04

****************************************************************************

210. PARAMETER 1
211. CODE AISC UNIFIED 2016
212. SGR 1 MEMB 3 TO 254
213. METHOD LRFD
214. MTY 2 MEMB 3 4
215. MTY 1 MEMB 5 TO 254
216. SEI 1 MEMB 3 TO 254
217. TRACK 1 MEMB 3 TO 254
218. CHECK CODE MEMB 3 TO 254
STEEL DESIGN

C:\Users\ceoen\Desktop\ONWORK~1\2022­0~1\2022­019 Frame Analysis.anl Page 11 of 518


Thursday, 7 July 2022 11:28 AM

STAAD SPACE ­­ PAGE NO. 12

STAAD.PRO CODE CHECKING ­ AISC 360­16 LRFD (V1.1)


*****************************************************

ALL UNITS ARE ­ KN METE (UNLESS OTHERWISE Noted).


***NOTE : AISC 360­16 Design Statement for STAAD.Pro.

*** AXIS CONVENTION ***:


========================

The capacity results and intermediate results in the report follow the notations
and axes labels as defined in the AISC 360­16 code.
The analysis results are reported in STAAD.Pro axis convention and the AISC 360:16
design results are reported in AISC 360­16 code axis convention.

AISC Spec. STAAD.Pro Description


­­­­­­­­­­­­ ­­­­­­­­­­­ ­­­­­­­­­­­­­
X Z Axis typically parallel to the sections principal major axis.
Y Y Axis typically parallel to the sections principal minor axis.
Z X Longitudinal axis perpendicular to the cross section.

SECTION FORCES AXIS MAPPING: ­

AISC Spec. STAAD.Pro Description


­­­­­­­­­­­­ ­­­­­­­­­­­ ­­­­­­­­­­­­­
Pz FX Axial force.
Vy FY Shear force along minor axis.
Vx FZ Shear force along major axis.
Tz MX Torsional moment.
My MY Bending moment about minor axis.
Mx MZ Bending moment about major axis.

*** DESIGN MESSAGES ***:


=======================

1. Section classification reported is for the cross section and loadcase that
produced the worst case design ratio for flexure/compression Capacity results.
2. Results for any Capacity/Check that is not relevant for a section/loadcase
based on the code clause in AISC 360­16 will not be shown in the report.
3. Bending results are reported as being “about” the relevant axis (X/Y), while
the results for shear are reported as being for shear forces “along” the axis.
E.g : Mx indicates bending about the X axis, while Vx indicates shear along
the X axis.

*** ABBREVIATIONS ***:


======================

F­T­B = Flexural­Torsional Buckling


L­T­B = Lateral­Torsional Buckling
F­L­B = Flange Local Buckling
W­L­B = Web Local Buckling
L­L­B = Leg Local Buckling
C­F­Y = Compression Flange Yielding
T­F­Y = Tension Flange Yielding

C:\Users\ceoen\Desktop\ONWORK~1\2022­0~1\2022­019 Frame Analysis.anl Page 12 of 518


Thursday, 7 July 2022 11:31 AM

STAAD SPACE ­­ PAGE NO. 13

STAAD.PRO CODE CHECKING ­ AISC 360­16 LRFD (V1.1)


*****************************************************

ALL UNITS ARE ­ KN METE (UNLESS OTHERWISE Noted).


­ Member : 3 (W12x72 I-BEAM AS COLUMN DESIGN)
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| Member No: 3 Profile: ST W12X72 (CHINESE SECTIO|S)
| Status: PASS Ratio: 0.189 Loadcase: 15 |
| Location: 0.00 Ref: Eq.H1­1b |
| Pz: 87.22 C Vy: ­.8248 Vx: ­11.28 |
| Tz: ­.4636E­02 My: 28.85 Mx: ­4.202 |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| SLENDERNESS |
| Actual Slenderness Ratio : 66.048 |
| Allowable Slenderness Ratio : 200.000 LOC : 0.00 |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| STRENGTH CHECKS |
| Critical L/C : 15 Ratio : 0.189(PASS) |
| Loc : 0.00 Condition : Eq.H1­1b |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| SECTION PROPERTIES (LOC: 0.00, PROPERTIES UNIT: CM ) |
| Ag : 1.361E+02 Axx : 1.037E+02 Ayy : 3.412E+01 |
| Ixx : 2.485E+04 Iyy : 8.117E+03 J : 1.220E+02 |
| Sxx+: 1.591E+03 Sxx­: 1.591E+03 Zxx : 1.770E+03 |
| Syy+: 5.326E+02 Syy­: 5.326E+02 Zyy : 8.062E+02 |
| Cw : 1.752E+06 x0 : 0.000E+00 y0 : 0.000E+00 |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| MATERIAL PROPERTIES |
| Fyld: 248211.281 Fu: 551580.625 |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| Actual Member Length: 5.100 |
| Design Parameters |
| Kx: 1.00 Ky: 1.00 NSF: 1.00 SLF: 1.00 CSP: 0.30 |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| COMPRESSION CLASSIFICATION (L/C: 9 LOC: 0.00) |
| p r CASE |
| Flange: NonSlender 8.96 N/A 15.89 Table.4.1a.Case1 |
| Web : NonSlender 25.49 N/A 42.29 Table.4.1a.Case5 |
| |
| FLEXURE CLASSIFICATION (L/C: 9 LOC: 0.00) |
| p r CASE |
| Flange: Compact 8.96 10.79 28.38 Table.4.1b.Case13 |
| Web : Compact 25.49 ****** ****** Table.4.1. |
| |
| SEISMIC CLASSIFICATION (L/C: 15 LOC: 0.00) |
| ­limit CASE |
| Flange: Compact 8.96 9.27 Table.D1.1 |
| Web : Compact 25.49 86.43 Table.D1.1 |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|

C:\Users\ceoen\Desktop\ONWORK~1\2022­0~1\2022­019 Frame Analysis.anl Page 13 of 518


Thursday, 7 July 2022 11:31 AM

STAAD SPACE ­­ PAGE NO. 14

STAAD.PRO CODE CHECKING ­ AISC 360­16 LRFD (V1.1)


*****************************************************

ALL UNITS ARE ­ KN METE (UNLESS OTHERWISE Noted).


­ Member : 3 Contd.
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| CHECKS FOR AXIAL TENSION |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| DEMAND CAPACITY RATIO REFERENCE L/C LOC |
| |
| Ten. Yld. 0.3042 3041. 0.000 Cl.D2 6 0.00 |
| Ten. Rupt. 0.3042 3041. 0.000 Cl.D2 6 0.00 |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| CHECKS FOR AXIAL COMPRESSION |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| DEMAND CAPACITY RATIO REFERENCE L/C LOC |
| |
| Flex. Buck. X 138.2 2821. 0.049 Cl.E3 9 0.00 |
| Flex. Buck. Y 138.2 2417. 0.057 Cl.E3 9 0.00 |
| Flex. Tor. Buck 138.2 2615. 0.053 Cl.E4 9 0.00 |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| CHECKS FOR SHEAR |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| DEMAND CAPACITY RATIO REFERENCE L/C LOC |
| |
| Shear X 11.28 1390. 0.008 Cl.G1 15 0.00 |
| Shear Y 6.818 508.2 0.013 Cl.G1 14 0.00 |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| CHECKS FOR BENDING |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| DEMAND CAPACITY RATIO REFERENCE L/C LOC |
| |
| Flex. Yld. X 34.66 395.4 0.088 Cl.F2.1 14 0.00 |
| Flex. Yld. Y ­28.85 180.1 0.160 Cl.F6.1 15 0.00 |
| L­T­B Abt X 34.66 395.4 0.088 Cl.F2.2 14 0.00 |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| CHECKS FOR AXIAL BEND INTERACTION |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| |
| RATIO CRITERIA L/C LOC |
| Clause H1 0.189 Eq.H1­1b 15 0.00 |
| Cl.H13­IP 0.104 Eq.H1­3a(H1­1b) 14 0.00 |
| Cl.H13­OP 0.084 Eq.H1­3b 9 0.00 |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| CHECKS FOR 341­16 SEISMIC CRITERIA |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| DEMAND CAPACITY RATIO REFERENCE L/C LOC |
| |
| Flex. Str.X 34.66 658.9 0.053 Eq.D1­1 14 0.00 |
| Flex. Str.Y ­28.85 300.2 0.096 Eq.D1­1 15 0.00 |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|

C:\Users\ceoen\Desktop\ONWORK~1\2022­0~1\2022­019 Frame Analysis.anl Page 14 of 518


Thursday, 7 July 2022 11:33 AM

STAAD SPACE ­­ PAGE NO. 25

STAAD.PRO CODE CHECKING ­ AISC 360­16 LRFD (V1.1)


*****************************************************

ALL UNITS ARE ­ KN METE (UNLESS OTHERWISE Noted).


­ Member : 9 (W12X30 I-BEAM AS TR-1 DESIGN)
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| Member No: 9 Profile: ST W12X30 (CHINESE SECTIO|S)
| Status: PASS Ratio: 0.454 Loadcase: 9 |
| Location: 3.20 Ref: Eq.H1­1b |
| Pz: 0.9069E­01 T Vy: ­30.41 Vx: ­.7845E­01 |
| Tz: ­.1009E­02 My: ­.2157 Mx: 70.65 |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| SLENDERNESS |
| Actual Slenderness Ratio : 82.902 |
| Allowable Slenderness Ratio : 300.000 LOC : 0.00 |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| STRENGTH CHECKS |
| Critical L/C : 9 Ratio : 0.454(PASS) |
| Loc : 3.20 Condition : Eq.H1­1b |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| SECTION PROPERTIES (LOC: 3.20, PROPERTIES UNIT: CM ) |
| Ag : 5.671E+01 Axx : 3.702E+01 Ayy : 2.063E+01 |
| Ixx : 9.906E+03 Iyy : 8.449E+02 J : 1.902E+01 |
| Sxx+: 6.342E+02 Sxx­: 6.342E+02 Zxx : 7.063E+02 |
| Syy+: 1.020E+02 Syy­: 1.020E+02 Zyy : 1.567E+02 |
| Cw : 1.919E+05 x0 : 0.000E+00 y0 : 0.000E+00 |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| MATERIAL PROPERTIES |
| Fyld: 248211.281 Fu: 551580.625 |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| Actual Member Length: 3.200 |
| Design Parameters |
| Kx: 1.00 Ky: 1.00 NSF: 1.00 SLF: 1.00 CSP: 0.30 |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| COMPRESSION CLASSIFICATION (L/C: 20 LOC: 125.98) |
| p r CASE |
| Flange: NonSlender 7.41 N/A 15.89 Table.4.1a.Case1 |
| Web : Slender 43.92 N/A 42.29 Table.4.1a.Case5 |
| |
| FLEXURE CLASSIFICATION (L/C: 20 LOC: 125.98) |
| p r CASE |
| Flange: Compact 7.41 10.79 28.38 Table.4.1b.Case10 |
| Web : Compact 43.92 106.72 161.78 Table.4.1b.Case15 |
| |
| SEISMIC CLASSIFICATION (L/C: 9 LOC: 125.98) |
| ­limit CASE |
| Flange: Compact 7.41 9.27 Table.D1.1 |
| Web : Compact 43.92 91.76 Table.D1.1 |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|

C:\Users\ceoen\Desktop\ONWORK~1\2022­0~1\2022­019 Frame Analysis.anl Page 25 of 518


Thursday, 7 July 2022 11:33 AM

STAAD SPACE ­­ PAGE NO. 26

STAAD.PRO CODE CHECKING ­ AISC 360­16 LRFD (V1.1)


*****************************************************

ALL UNITS ARE ­ KN METE (UNLESS OTHERWISE Noted).


­ Member : 9 Contd.
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| CHECKS FOR AXIAL TENSION |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| DEMAND CAPACITY RATIO REFERENCE L/C LOC |
| |
| Ten. Yld. 1.271 1267. 0.001 Cl.D2 16 0.00 |
| Ten. Rupt. 1.271 1267. 0.001 Cl.D2 16 0.00 |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| CHECKS FOR AXIAL COMPRESSION |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| DEMAND CAPACITY RATIO REFERENCE L/C LOC |
| |
| Flex. Buck. X 1.178 1222. 0.001 Cl.E3 20 0.00 |
| Flex. Buck. Y 1.178 882.2 0.001 Cl.E3 20 0.00 |
| Flex. Tor. Buck 1.178 1021. 0.001 Cl.E4 20 0.00 |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| CHECKS FOR SHEAR |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| DEMAND CAPACITY RATIO REFERENCE L/C LOC |
| |
| Shear X 1.247 496.1 0.003 Cl.G1 17 0.00 |
| Shear Y 30.41 307.3 0.099 Cl.G1 9 3.20 |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| CHECKS FOR BENDING |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| DEMAND CAPACITY RATIO REFERENCE L/C LOC |
| |
| Flex. Yld. X 70.65 157.8 0.448 Cl.F2.1 9 3.20 |
| Flex. Yld. Y 3.593 35.00 0.103 Cl.F6.1 17 3.20 |
| L­T­B Abt X 70.65 157.8 0.448 Cl.F2.2 9 3.20 |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| CHECKS FOR AXIAL BEND INTERACTION |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| |
| RATIO CRITERIA L/C LOC |
| Clause H1 0.454 Eq.H1­1b 9 3.20 |
| Cl.H13­IP 0.295 Eq.H1­3a(H1­1b) 12 3.20 |
| Cl.H13­OP 0.032 Eq.H1­3b 14 3.20 |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| CHECKS FOR 341­16 SEISMIC CRITERIA |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| DEMAND CAPACITY RATIO REFERENCE L/C LOC |
| |
| Flex. Str.X 70.65 263.0 0.269 Eq.D1­1 9 3.20 |
| Flex. Str.Y 3.593 58.33 0.062 Eq.D1­1 17 3.20 |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|

C:\Users\ceoen\Desktop\ONWORK~1\2022­0~1\2022­019 Frame Analysis.anl Page 26 of 518


Thursday, 7 July 2022 11:34 AM

STAAD SPACE ­­ PAGE NO. 23

STAAD.PRO CODE CHECKING ­ AISC 360­16 LRFD (V1.1)


*****************************************************

ALL UNITS ARE ­ KN METE (UNLESS OTHERWISE Noted).


­ Member : 8 (W12X30 I-BEAM AS TR-2 DESIGN)
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| Member No: 8 Profile: ST W12X30 (CHINESE SECTIO|S)
| Status: PASS Ratio: 0.484 Loadcase: 9 |
| Location: 3.20 Ref: Eq.H1­1b |
| Pz: 0.1446 T Vy: ­32.21 Vx: ­.1857E­02 |
| Tz: ­.3433E­04 My: ­.5008E­02 Mx: 76.41 |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| SLENDERNESS |
| Actual Slenderness Ratio : 82.902 |
| Allowable Slenderness Ratio : 300.000 LOC : 0.00 |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| STRENGTH CHECKS |
| Critical L/C : 9 Ratio : 0.484(PASS) |
| Loc : 3.20 Condition : Eq.H1­1b |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| SECTION PROPERTIES (LOC: 3.20, PROPERTIES UNIT: CM ) |
| Ag : 5.671E+01 Axx : 3.702E+01 Ayy : 2.063E+01 |
| Ixx : 9.906E+03 Iyy : 8.449E+02 J : 1.902E+01 |
| Sxx+: 6.342E+02 Sxx­: 6.342E+02 Zxx : 7.063E+02 |
| Syy+: 1.020E+02 Syy­: 1.020E+02 Zyy : 1.567E+02 |
| Cw : 1.919E+05 x0 : 0.000E+00 y0 : 0.000E+00 |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| MATERIAL PROPERTIES |
| Fyld: 248211.281 Fu: 551580.625 |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| Actual Member Length: 3.200 |
| Design Parameters |
| Kx: 1.00 Ky: 1.00 NSF: 1.00 SLF: 1.00 CSP: 0.30 |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| COMPRESSION CLASSIFICATION (L/C: 21 LOC: 125.98) |
| p r CASE |
| Flange: NonSlender 7.41 N/A 15.89 Table.4.1a.Case1 |
| Web : Slender 43.92 N/A 42.29 Table.4.1a.Case5 |
| |
| FLEXURE CLASSIFICATION (L/C: 21 LOC: 125.98) |
| p r CASE |
| Flange: Compact 7.41 10.79 28.38 Table.4.1b.Case10 |
| Web : Compact 43.92 106.72 161.78 Table.4.1b.Case15 |
| |
| SEISMIC CLASSIFICATION (L/C: 9 LOC: 125.98) |
| ­limit CASE |
| Flange: Compact 7.41 9.27 Table.D1.1 |
| Web : Compact 43.92 91.75 Table.D1.1 |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|

C:\Users\ceoen\Desktop\ONWORK~1\2022­0~1\2022­019 Frame Analysis.anl Page 23 of 518


Thursday, 7 July 2022 11:34 AM

STAAD SPACE ­­ PAGE NO. 24

STAAD.PRO CODE CHECKING ­ AISC 360­16 LRFD (V1.1)


*****************************************************

ALL UNITS ARE ­ KN METE (UNLESS OTHERWISE Noted).


­ Member : 8 Contd.
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| CHECKS FOR AXIAL TENSION |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| DEMAND CAPACITY RATIO REFERENCE L/C LOC |
| |
| Ten. Yld. 1.541 1267. 0.001 Cl.D2 17 0.00 |
| Ten. Rupt. 1.541 1267. 0.001 Cl.D2 17 0.00 |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| CHECKS FOR AXIAL COMPRESSION |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| DEMAND CAPACITY RATIO REFERENCE L/C LOC |
| |
| Flex. Buck. X 1.392 1222. 0.001 Cl.E3 21 0.00 |
| Flex. Buck. Y 1.392 882.2 0.002 Cl.E3 21 0.00 |
| Flex. Tor. Buck 1.392 1021. 0.001 Cl.E4 21 0.00 |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| CHECKS FOR SHEAR |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| DEMAND CAPACITY RATIO REFERENCE L/C LOC |
| |
| Shear X 1.343 496.1 0.003 Cl.G1 14 0.00 |
| Shear Y 32.21 307.3 0.105 Cl.G1 9 3.20 |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| CHECKS FOR BENDING |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| DEMAND CAPACITY RATIO REFERENCE L/C LOC |
| |
| Flex. Yld. X 76.41 157.8 0.484 Cl.F2.1 9 3.20 |
| Flex. Yld. Y 3.534 35.00 0.101 Cl.F6.1 14 3.20 |
| L­T­B Abt X 76.41 157.8 0.484 Cl.F2.2 9 3.20 |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| CHECKS FOR AXIAL BEND INTERACTION |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| |
| RATIO CRITERIA L/C LOC |
| Clause H1 0.484 Eq.H1­1b 9 3.20 |
| Cl.H13­IP 0.339 Eq.H1­3a(H1­1b) 15 3.20 |
| Cl.H13­OP 0.044 Eq.H1­3b 15 3.20 |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| CHECKS FOR 341­16 SEISMIC CRITERIA |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| DEMAND CAPACITY RATIO REFERENCE L/C LOC |
| |
| Flex. Str.X 76.41 263.0 0.291 Eq.D1­1 9 3.20 |
| Flex. Str.Y 3.534 58.33 0.061 Eq.D1­1 14 3.20 |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|

C:\Users\ceoen\Desktop\ONWORK~1\2022­0~1\2022­019 Frame Analysis.anl Page 24 of 518


Thursday, 7 July 2022 11:35 AM

STAAD SPACE ­­ PAGE NO. 17

STAAD.PRO CODE CHECKING ­ AISC 360­16 LRFD (V1.1)


*****************************************************

ALL UNITS ARE ­ KN METE (UNLESS OTHERWISE Noted).


­ Member : 5 (W12X30 I-BEAM AS TR-3 DESIGN)
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| Member No: 5 Profile: ST W12X30 (CHINESE SECTIO|S)
| Status: PASS Ratio: 0.390 Loadcase: 9 |
| Location: 0.00 Ref: Cl.F2.1 |
| Pz: 0.000 T Vy: 38.75 Vx: ­.9419E­22 |
| Tz: 0.2059E­07 My: ­.2297E­21 Mx: 61.52 |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| SLENDERNESS |
| Actual Slenderness Ratio : 82.902 |
| Allowable Slenderness Ratio : 300.000 LOC : 0.00 |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| STRENGTH CHECKS |
| Critical L/C : 9 Ratio : 0.390(PASS) |
| Loc : 0.00 Condition : Cl.F2.1 |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| SECTION PROPERTIES (LOC: 0.00, PROPERTIES UNIT: CM ) |
| Ag : 5.671E+01 Axx : 3.702E+01 Ayy : 2.063E+01 |
| Ixx : 9.906E+03 Iyy : 8.449E+02 J : 1.902E+01 |
| Sxx+: 6.342E+02 Sxx­: 6.342E+02 Zxx : 7.063E+02 |
| Syy+: 1.020E+02 Syy­: 1.020E+02 Zyy : 1.567E+02 |
| Cw : 1.919E+05 x0 : 0.000E+00 y0 : 0.000E+00 |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| MATERIAL PROPERTIES |
| Fyld: 248211.281 Fu: 551580.625 |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| Actual Member Length: 3.200 |
| Design Parameters |
| Kx: 1.00 Ky: 1.00 NSF: 1.00 SLF: 1.00 CSP: 0.30 |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| COMPRESSION CLASSIFICATION (L/C: 3 LOC: 125.98) |
| p r CASE |
| Flange: NonSlender 7.41 N/A 15.89 Table.4.1a.Case1 |
| Web : Slender 43.92 N/A 42.29 Table.4.1a.Case5 |
| |
| FLEXURE CLASSIFICATION (L/C: 3 LOC: 125.98) |
| p r CASE |
| Flange: Compact 7.41 10.79 28.38 Table.4.1b.Case10 |
| Web : Compact 43.92 106.72 161.78 Table.4.1b.Case15 |
| |
| SEISMIC CLASSIFICATION (L/C: 9 LOC: 0.00) |
| ­limit CASE |
| Flange: Compact 7.41 9.27 Table.D1.1 |
| Web : Compact 43.92 91.77 Table.D1.1 |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|

C:\Users\ceoen\Desktop\ONWORK~1\2022­0~1\2022­019 Frame Analysis.anl Page 17 of 518


Thursday, 7 July 2022 11:35 AM

STAAD SPACE ­­ PAGE NO. 18

STAAD.PRO CODE CHECKING ­ AISC 360­16 LRFD (V1.1)


*****************************************************

ALL UNITS ARE ­ KN METE (UNLESS OTHERWISE Noted).


­ Member : 5 Contd.
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| CHECKS FOR AXIAL TENSION |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| DEMAND CAPACITY RATIO REFERENCE L/C LOC |
| |
| Ten. Yld. 0.000 1267. 0.000 Cl.D2 3 0.00 |
| Ten. Rupt. 0.000 1267. 0.000 Cl.D2 3 0.00 |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| CHECKS FOR AXIAL COMPRESSION |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| DEMAND CAPACITY RATIO REFERENCE L/C LOC |
| |
| Flex. Buck. X 0.000 1222. 0.000 Cl.E3 3 0.00 |
| Flex. Buck. Y 0.000 882.2 0.000 Cl.E3 3 0.00 |
| Flex. Tor. Buck 0.000 1021. 0.000 Cl.E4 3 0.00 |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| CHECKS FOR SHEAR |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| DEMAND CAPACITY RATIO REFERENCE L/C LOC |
| |
| Shear X 0.3087E­15 496.1 0.000 Cl.G1 16 0.00 |
| Shear Y 38.75 307.3 0.126 Cl.G1 9 0.00 |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| CHECKS FOR BENDING |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| DEMAND CAPACITY RATIO REFERENCE L/C LOC |
| |
| Flex. Yld. X 61.52 157.8 0.390 Cl.F2.1 9 0.00 |
| Flex. Yld. Y 0.8028E­15 35.00 0.000 Cl.F6.1 14 0.00 |
| L­T­B Abt X 61.52 157.8 0.390 Cl.F2.2 9 0.00 |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| CHECKS FOR AXIAL BEND INTERACTION |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| |
| RATIO CRITERIA L/C LOC |
| Clause H1 0.390 Eq.H1­1b 9 0.00 |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| CHECKS FOR 341­16 SEISMIC CRITERIA |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| DEMAND CAPACITY RATIO REFERENCE L/C LOC |
| |
| Flex. Str.X 61.52 263.0 0.234 Eq.D1­1 9 0.00 |
| Flex. Str.Y 0.8028E­15 58.33 0.000 Eq.D1­1 14 0.00 |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|

C:\Users\ceoen\Desktop\ONWORK~1\2022­0~1\2022­019 Frame Analysis.anl Page 18 of 518


Thursday, 7 July 2022 11:37 AM

STAAD SPACE ­­ PAGE NO. 251

STAAD.PRO CODE CHECKING ­ AISC 360­16 LRFD (V1.1)


*****************************************************

ALL UNITS ARE ­ KN METE (UNLESS OTHERWISE Noted).


­ Member : 122 (2L - 50mm x 50mm x 3mm THK. ANGLE BAR FOR TOP/BOT CHORD)
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| Member No: 122 Profile: SD L50X50X3 (CHINESE SECTIO|S)
| Status: PASS Ratio: 0.309 Loadcase: 15 |
| Location: 0.64 Ref: Eq.H1­1b |
| Pz: 15.55 T Vy: ­.2759 Vx: 0.2873 |
| Tz: 0.2082E­03 My: 0.3179 Mx: 0.8778E­01 |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| SLENDERNESS |
| Actual Slenderness Ratio : 41.244 |
| Allowable Slenderness Ratio : 300.000 LOC : 0.00 |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| STRENGTH CHECKS |
| Critical L/C : 15 Ratio : 0.309(PASS) |
| Loc : 0.64 Condition : Eq.H1­1b |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| SECTION PROPERTIES (LOC: 0.64, PROPERTIES UNIT: CM ) |
| Ag : 5.940E+00 Axx : 3.000E+00 Ayy : 3.000E+00 |
| Ixx : 1.430E+01 Iyy : 3.016E+01 J : 1.782E­01 |
| Sxx+: 1.072E+01 Sxx­: 3.901E+00 Zxx : 7.076E+00 |
| Syy+: 5.690E+00 Syy­: 5.690E+00 Zyy : 9.669E+00 |
| Cw : 1.919E+05 x0 : 0.000E+00 y0 : ­1.184E+00 |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| MATERIAL PROPERTIES |
| Fyld: 248211.281 Fu: 551580.625 |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| Actual Member Length: 0.640 |
| Design Parameters |
| Kx: 1.00 Ky: 1.00 NSF: 1.00 SLF: 1.00 CSP: 0.30 |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| COMPRESSION CLASSIFICATION (L/C: 5 LOC: 25.20) |
| p r CASE |
| Flange: Slender 16.67 N/A 12.77 Table.4.1a.Case3 |
| Web : Slender 16.67 N/A 12.77 Table.4.1a.Case3 |
| |
| FLEXURE CLASSIFICATION (L/C: 5 LOC: 25.20) |
| p r CASE |
| Flange: NonCompact 16.67 15.33 25.83 Table.4.1b.Case12 |
| Web : NonCompact 16.67 15.33 25.83 Table.4.1b.Case12 |
| |
| SEISMIC CLASSIFICATION (L/C: 3 LOC: 0.00) |
| ­limit CASE |
| Flange: NonCompact 16.67 9.27 Table.D1.1 |
| Web : NonCompact 16.67 9.27 Table.D1.1 |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|

C:\Users\ceoen\Desktop\ONWORK~1\2022­0~1\2022­019 Frame Analysis.anl Page 251 of 518


Thursday, 7 July 2022 11:37 AM

STAAD SPACE ­­ PAGE NO. 252

STAAD.PRO CODE CHECKING ­ AISC 360­16 LRFD (V1.1)


*****************************************************

ALL UNITS ARE ­ KN METE (UNLESS OTHERWISE Noted).


­ Member : 122 Contd.
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| CHECKS FOR AXIAL TENSION |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| DEMAND CAPACITY RATIO REFERENCE L/C LOC |
| |
| Ten. Yld. 19.57 132.7 0.148 Cl.D2 9 0.00 |
| Ten. Rupt. 19.57 132.7 0.148 Cl.D2 9 0.00 |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| CHECKS FOR AXIAL COMPRESSION |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| DEMAND CAPACITY RATIO REFERENCE L/C LOC |
| |
| Flex. Buck. X 0.1173 106.5 0.001 Cl.E3 5 0.00 |
| Flex. Buck. Y 0.1173 109.9 0.001 Cl.E3 5 0.00 |
| Flex. Tor. Buck 0.1173 109.9 0.001 Cl.E4 5 0.00 |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| CHECKS FOR SHEAR |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| DEMAND CAPACITY RATIO REFERENCE L/C LOC |
| |
| Shear X 0.3000 40.21 0.007 Cl.G1 17 0.00 |
| Shear Y 0.3962 40.21 0.010 Cl.G1 9 0.64 |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| CHECKS FOR BENDING |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| DEMAND CAPACITY RATIO REFERENCE L/C LOC |
| |
| Flex. Yld. X 0.1221 1.307 0.093 Cl.F9.1 9 0.64 |
| Flex. Yld. Y 0.3429 2.034 0.169 Cl.F6.1 17 0.64 |
| L­T­B Abt X 0.1221 1.083 0.113 Cl.F9.2 9 0.64 |
| L­T­B Abt Y 0.3429 1.874 0.183 Cl.F9.2 17 0.64 |
| F­L­B Abt X ­.8171E­02 3.402 0.002 Cl.F9.3 9 0.11 |
| F­L­B Abt Y 0.3429 1.888 0.182 Cl.F6.2 17 0.64 |
| W­L­B Abt X 0.1221 1.238 0.099 Cl.F9.4 9 0.64 |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| CHECKS FOR AXIAL BEND INTERACTION |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| |
| RATIO CRITERIA L/C LOC |
| Clause H1 0.309 Eq.H1­1b 15 0.64 |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|

WARNING: SEISMIC PROVISIONS WAS NOT CHECKED AS THE SECTION FOR MEMBER# 122
IS NONCOMPACT AS PER TABLE D1.1 OF AISC341­2016 SPECIFICATION.

C:\Users\ceoen\Desktop\ONWORK~1\2022­0~1\2022­019 Frame Analysis.anl Page 252 of 518


Thursday, 7 July 2022 11:39 AM

STAAD SPACE ­­ PAGE NO. 253

STAAD.PRO CODE CHECKING ­ AISC 360­16 LRFD (V1.1)


*****************************************************

ALL UNITS ARE ­ KN METE (UNLESS OTHERWISE Noted).


­ Member : 123 (2L - 50mm x 50mm x 3mm THK. ANGLE BAR FOR VERTICAL WEB CHORD)
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| Member No: 123 Profile: SD L50X50X3 (CHINESE SECTIO|S)
| Status: PASS Ratio: 0.111 Loadcase: 9 |
| Location: 0.60 Ref: Eq.H1­1b |
| Pz: 6.061 T Vy: 0.3004 Vx: 0.5098E­03 |
| Tz: ­.1614E­03 My: ­.8721E­04 Mx: ­.9593E­01 |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| SLENDERNESS |
| Actual Slenderness Ratio : 38.666 |
| Allowable Slenderness Ratio : 300.000 LOC : 0.00 |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| STRENGTH CHECKS |
| Critical L/C : 9 Ratio : 0.111(PASS) |
| Loc : 0.60 Condition : Eq.H1­1b |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| SECTION PROPERTIES (LOC: 0.60, PROPERTIES UNIT: CM ) |
| Ag : 5.940E+00 Axx : 3.000E+00 Ayy : 3.000E+00 |
| Ixx : 1.430E+01 Iyy : 3.016E+01 J : 1.782E­01 |
| Sxx+: 1.072E+01 Sxx­: 3.901E+00 Zxx : 7.076E+00 |
| Syy+: 5.690E+00 Syy­: 5.690E+00 Zyy : 9.669E+00 |
| Cw : 1.919E+05 x0 : 0.000E+00 y0 : ­1.184E+00 |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| MATERIAL PROPERTIES |
| Fyld: 248211.281 Fu: 551580.625 |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| Actual Member Length: 0.600 |
| Design Parameters |
| Kx: 1.00 Ky: 1.00 NSF: 1.00 SLF: 1.00 CSP: 0.30 |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| COMPRESSION CLASSIFICATION (L/C: 5 LOC: 23.62) |
| p r CASE |
| Flange: Slender 16.67 N/A 12.77 Table.4.1a.Case3 |
| Web : Slender 16.67 N/A 12.77 Table.4.1a.Case3 |
| |
| FLEXURE CLASSIFICATION (L/C: 5 LOC: 23.62) |
| p r CASE |
| Flange: NonCompact 16.67 15.33 25.83 Table.4.1b.Case12 |
| Web : NonCompact 16.67 15.33 25.83 Table.4.1b.Case12 |
| |
| SEISMIC CLASSIFICATION (L/C: 3 LOC: 0.00) |
| ­limit CASE |
| Flange: NonCompact 16.67 9.27 Table.D1.1 |
| Web : NonCompact 16.67 9.27 Table.D1.1 |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|

C:\Users\ceoen\Desktop\ONWORK~1\2022­0~1\2022­019 Frame Analysis.anl Page 253 of 518


Thursday, 7 July 2022 11:39 AM

STAAD SPACE ­­ PAGE NO. 254

STAAD.PRO CODE CHECKING ­ AISC 360­16 LRFD (V1.1)


*****************************************************

ALL UNITS ARE ­ KN METE (UNLESS OTHERWISE Noted).


­ Member : 123 Contd.
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| CHECKS FOR AXIAL TENSION |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| DEMAND CAPACITY RATIO REFERENCE L/C LOC |
| |
| Ten. Yld. 6.061 132.7 0.046 Cl.D2 9 0.60 |
| Ten. Rupt. 6.061 132.7 0.046 Cl.D2 9 0.60 |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| CHECKS FOR AXIAL COMPRESSION |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| DEMAND CAPACITY RATIO REFERENCE L/C LOC |
| |
| Flex. Buck. X 0.3839E­02 107.2 0.000 Cl.E3 5 0.00 |
| Flex. Buck. Y 0.3839E­02 110.3 0.000 Cl.E3 5 0.00 |
| Flex. Tor. Buck 0.3839E­02 110.3 0.000 Cl.E4 5 0.00 |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| CHECKS FOR SHEAR |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| DEMAND CAPACITY RATIO REFERENCE L/C LOC |
| |
| Shear X 0.2629E­02 40.21 0.000 Cl.G1 14 0.00 |
| Shear Y 0.3004 40.21 0.007 Cl.G1 9 0.00 |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| CHECKS FOR BENDING |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| DEMAND CAPACITY RATIO REFERENCE L/C LOC |
| |
| Flex. Yld. X ­.9593E­01 1.394 0.069 Cl.F9.1 9 0.60 |
| Flex. Yld. Y 0.1272E­02 2.034 0.001 Cl.F6.1 16 0.60 |
| L­T­B Abt X 0.8428E­01 1.085 0.078 Cl.F9.2 9 0.00 |
| L­T­B Abt Y 0.1272E­02 1.892 0.001 Cl.F9.2 16 0.60 |
| F­L­B Abt X ­.9593E­01 3.402 0.028 Cl.F9.3 9 0.60 |
| F­L­B Abt Y 0.1272E­02 1.888 0.001 Cl.F6.2 16 0.60 |
| W­L­B Abt X 0.8428E­01 1.238 0.068 Cl.F9.4 9 0.00 |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| CHECKS FOR AXIAL BEND INTERACTION |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| |
| RATIO CRITERIA L/C LOC |
| Clause H1 0.111 Eq.H1­1b 9 0.60 |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|

WARNING: SEISMIC PROVISIONS WAS NOT CHECKED AS THE SECTION FOR MEMBER# 123
IS NONCOMPACT AS PER TABLE D1.1 OF AISC341­2016 SPECIFICATION.

C:\Users\ceoen\Desktop\ONWORK~1\2022­0~1\2022­019 Frame Analysis.anl Page 254 of 518


Thursday, 7 July 2022 11:41 AM

STAAD SPACE ­­ PAGE NO. 279

STAAD.PRO CODE CHECKING ­ AISC 360­16 LRFD (V1.1)


*****************************************************

ALL UNITS ARE ­ KN METE (UNLESS OTHERWISE Noted).


­ Member : 136 (L - 50mm x 50mm x 3mm THK. ANGLE BAR FOR DIAGONAL WEB CHORD)
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| Member No: 136 Profile: ST L50X50X3 (CHINESE SECTIO|S)
| Status: PASS Ratio: 0.245 Loadcase: 9 |
| Location: 0.88 Ref: Eq.H2­1 |
| Pz: 10.44 C Vy: 0.5902E­02 Vx: 0.6445E­02 |
| Tz: 0.2586E­08 My: ­.1376E­03 Mx: ­.2056E­04 |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| SLENDERNESS |
| Actual Slenderness Ratio : 87.727 |
| Allowable Slenderness Ratio : 200.000 LOC : 0.00 |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| STRENGTH CHECKS |
| Critical L/C : 9 Ratio : 0.245(PASS) |
| Loc : 0.88 Condition : Eq.H2­1 |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| SECTION PROPERTIES (LOC: 0.88, PROPERTIES UNIT: CM ) |
| Ag : 2.970E+00 Axx : 1.500E+00 Ayy : 1.500E+00 |
| Ixx : 7.152E+00 Iyy : 7.152E+00 J : 8.910E­02 |
| Sxx+: 1.574E+00 Sxx­: 1.801E+00 Zxx : 2.834E+00 |
| Syy+: 3.205E+00 Syy­: 3.205E+00 Zyy : 5.770E+00 |
| Cw : 1.919E+05 x0 : ­1.184E+00 y0 : ­1.184E+00 |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| MATERIAL PROPERTIES |
| Fyld: 248211.281 Fu: 551580.625 |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| Actual Member Length: 0.877 |
| Design Parameters |
| Kx: 1.00 Ky: 1.00 NSF: 1.00 SLF: 1.00 CSP: 0.30 |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| COMPRESSION CLASSIFICATION (L/C: 9 LOC: 34.54) |
| p r CASE |
| Flange: Slender 16.67 N/A 12.77 Table.4.1a.Case3 |
| Web : Slender 16.67 N/A 12.77 Table.4.1a.Case3 |
| |
| FLEXURE CLASSIFICATION (L/C: 9 LOC: 34.54) |
| p r CASE |
| Flange: NonCompact 16.67 15.33 25.83 Table.4.1b.Case12 |
| Web : NonCompact 16.67 15.33 25.83 Table.4.1b.Case12 |
| |
| SEISMIC CLASSIFICATION (L/C: 3 LOC: 0.00) |
| ­limit CASE |
| Flange: NonCompact 16.67 9.27 Table.D1.1 |
| Web : NonCompact 16.67 9.27 Table.D1.1 |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|

C:\Users\ceoen\Desktop\ONWORK~1\2022­0~1\2022­019 Frame Analysis.anl Page 279 of 518


Thursday, 7 July 2022 11:41 AM

STAAD SPACE ­­ PAGE NO. 280

STAAD.PRO CODE CHECKING ­ AISC 360­16 LRFD (V1.1)


*****************************************************

ALL UNITS ARE ­ KN METE (UNLESS OTHERWISE Noted).


­ Member : 136 Contd.
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| CHECKS FOR AXIAL TENSION |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| DEMAND CAPACITY RATIO REFERENCE L/C LOC |
| |
| Ten. Yld. 0.5733E­02 66.35 0.000 Cl.D2 5 0.00 |
| Ten. Rupt. 0.5733E­02 66.35 0.000 Cl.D2 5 0.00 |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| CHECKS FOR AXIAL COMPRESSION |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| DEMAND CAPACITY RATIO REFERENCE L/C LOC |
| |
| Flex. Buck. X 10.44 50.46 0.207 Cl.E3 9 0.88 |
| Flex. Buck. Y 10.44 50.46 0.207 Cl.E3 9 0.88 |
| Flex. Buck. U 10.44 52.64 0.198 Cl.E3 9 0.88 |
| Flex. Buck. V 10.44 42.75 0.244 Cl.E3 9 0.88 |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| CHECKS FOR SHEAR |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| DEMAND CAPACITY RATIO REFERENCE L/C LOC |
| |
| Shear X 0.7372E­02 20.11 0.000 Cl.G1 8 0.88 |
| Shear Y 0.7400E­02 20.11 0.000 Cl.G1 8 0.00 |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| CHECKS FOR BENDING |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| DEMAND CAPACITY RATIO REFERENCE L/C LOC |
| |
| Flex. Yld. X ­.2198E­02 0.6536 0.003 Cl.F10.1 14 0.44 |
| Flex. Yld. Y ­.2250E­02 0.6536 0.003 Cl.F10.1 16 0.44 |
| Flex. Yld. U 0.1558E­02 1.074 0.001 Cl.F10.1 15 0.00 |
| Flex. Yld. V ­.2174E­02 0.5276 0.004 Cl.F10.1 8 0.44 |
| L­T­B Abt X ­.2198E­02 0.4411 0.005 Cl.F10.2 14 0.44 |
| L­T­B Abt Y ­.2250E­02 0.4409 0.005 Cl.F10.2 16 0.44 |
| L­T­B Abt U 0.1558E­02 0.9846 0.002 Cl.F10.2 15 0.00 |
| F­L­B Abt X ­.2198E­02 0.4950 0.004 Cl.F10.3 14 0.44 |
| F­L­B Abt Y ­.2250E­02 0.4950 0.005 Cl.F10.3 16 0.44 |
| F­L­B Abt U 0.1558E­02 1.017 0.002 Cl.F10.3 15 0.00 |
| F­L­B Abt V ­.2174E­02 0.5713 0.004 Cl.F10.3 8 0.44 |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| CHECKS FOR AXIAL BEND INTERACTION |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|
| |
| RATIO CRITERIA L/C LOC |
| Clause H2 0.245 Eq.H2­1 9 0.88 |
|­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­|

WARNING: SEISMIC PROVISIONS WAS NOT CHECKED AS THE SECTION FOR MEMBER# 136
IS NONCOMPACT AS PER TABLE D1.1 OF AISC341­2016 SPECIFICATION.

C:\Users\ceoen\Desktop\ONWORK~1\2022­0~1\2022­019 Frame Analysis.anl Page 280 of 518


Proposed Petro Gazz Apopong
Apopong, General Santos City

MEMBER NAME : PEDESTAL

1. General Information
(1) Design Code : ACI318M-14
(2) Code Unit : N, mm

2. Material
(1) F'c : 21.00MPa
(2) Fy : 276MPa
(3) Fys : 230MPa

500
3. Section
(1) Section Size : 500 x 500mm
(2) Lx : 0.200m
(3) Ly : 0.200m
(4) Kx : 0.500
(5) Ky : 0.500
(6) Splicing Limit : 50%
(7) Frame Type : Braced Frame 500

4. Forces
(1) Pu : 140kN
(2) Mux : 53.49kN·m
(3) Muy : 31.11kN·m
(4) Vux : 11.30kN
(5) Vuy : 10.13kN
(6) Pux : 140kN
(7) Puy : 140kN

5. Factors
(1) Cmx : 0.600
(2) Cmy : 0.600
(3) βdns : 0.600

6. Rebar
(1) Main Bar
Layer-1 : 16 - 5 - d16 ( Cc = 40.00mm, As = 3,218mm² )
Layer-2 :-
Layer-3 :-
As.total : 3,218mm²
(2) Hoop Bar
End : d10@100
Middle : d10@150
(3) Tie Bar
Apply Tie Bar to Shear Check : Yes
Tie Bar : d10 ( Fy = 230MPa )

7. Calculation Summary
(1) Check Design Parameter
Category Value Criteria Ratio Note
Rebar Ratio ( Min. ) 0.0129 0.0100 0.777 ρmin / ρ
Rebar Ratio ( Max. ) 0.0129 0.0800 0.161 ρ / ρmax

(2) Check Moment Capacity ( Neutral axis )


Category Value Criteria Ratio Note
Moment Capacity ( Dir. X ) ( kN·m ) 53.49 223 0.240 Mux / øMnx

2022-08-16 19:36 1
Proposed Petro Gazz Apopong
Apopong, General Santos City

MEMBER NAME : PEDESTAL

Moment Capacity ( Dir. Y ) ( kN·m ) 31.11 135 0.231 Muy / øMny


Axial Capacity ( kN ) 140 588 0.237 Pu / øPn
Moment Capacity ( kN·m ) 61.88 261 0.237 Mu / øMn

(3) Check Shear Capacity


Category Value Criteria Ratio Note
Shear Strength ( Dir. X ) ( kN ) 11.30 327 0.0346 Vux / øVnx
Spacing Limits for Reinforcement ( Dir. X ) ( mm ) 100 256 0.391 sx / sx,max
Shear Strength ( Dir. Y ) ( kN ) 10.13 327 0.0310 Vux / øVnx
Spacing Limits for Reinforcement ( Dir. Y ) ( mm ) 100 256 0.391 sy / sy,max

8. Check Slenderness Ratio


(1) Calculate radii of gyration
rx = 0.3D = 150mm
ry = 0.3B = 150mm
(2) Calculate slenderness ratio
M1x
= 0.000
M2x
M1y
= 0.000
M2y
kx lux M1x
= 0.667 < min(34 + 12 , 40.0) = 34.00 → Not Slender
rx M2x
ky luy M1y
= 0.667 < min(34 + 12 , 40.0) = 34.00 → Not Slender
ry M2y
9. Check Magnified Moment
(1) Calculate moment magnification factor
δns.x = 1.000
δns.y = 1.000

10. Check Minimum Moment


(1) Calculate minimum eccentricity
emin.x = 15 + 0.03D = 30.00mm
emin.y = 15 + 0.03B = 30.00mm
(2) Calculate minimum moment
Mmin.x = Pu emin.x = 4.188kN·m
Mmin.y = Pu emin.y = 4.188kN·m

11. Check Design Moment


(1) Calculate design moment
Mc.x = Mux = 53.49kN·m
Mc.y = Muy = 31.11kN·m
Mc = 61.88kN·m

12. Check Design Parameter


Calculation Summary ( Check Design Parameter )
Category Value Criteria Ratio Note
Rebar Ratio ( Min. ) 0.0129 0.0100 0.777 ρmin / ρ
Rebar Ratio ( Max. ) 0.0129 0.0800 0.161 ρ / ρmax

Rebar Ratio ( Min. ) 0.78

Rebar Ratio ( Max. ) 0.16

0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20 1.30 1.40 1.50
(1) Calculate rebar ratio
2022-08-16 19:36 2
Proposed Petro Gazz Apopong
Apopong, General Santos City

MEMBER NAME : PEDESTAL

Ag = 250,000mm², Ast = 3,218mm²


ρmin = 0.0100, ρmax = 0.0800, ρ = 0.0129
ρmin < ρ < ρmax → O.K
(2) Calculate eccentricity
ex = Mc.y / Pu = 223mm
ey = Mc.x / Pu = 383mm
e = Mc / Pu = 443mm
Rotation angle of neutral axis = 30.18°
(3) Calculate concentric axial load capacity
P0 = 0.85f'c ( Ag - Ast ) + fy Ast = 5,293kN
P0.max = 0.80P0 = 4,234kN
Pt = fy Ast = -888kN

13. Check Moment Capacity ( Balanced axis )


(1) Calculate capacity of compression stress block
β1 = 0.850
c = 431mm, a = β1 ㆍ c = 366mm
Acom = 139,083mm²
ccx = 43.56mm, ccy = 98.25mm
Cc = 0.85 ㆍ f'c ㆍ Acom = 2,483kN
Mnx = Cc ㆍ ccy = 244kN·m
Mny = Cc ㆍ ccx = 108kN·m
(2) Calculate capacity of rebar
ds fs As Fs dy Mnx dx Mny
i εs
(mm) (MPa) (mm²) (kN) (mm) (kN) (mm) (kN)
1 629 -0.001380 -276 201 -55.50 -210 11.66 -210 11.66
2 538 -0.000748 -150 201 -30.08 -105 3.158 -210 6.317
3 447 -0.000116 -23.15 201 -4.655 0.000 0.000 -210 0.978
4 357 0.000516 103 201 20.77 105 2.181 -210 -4.362
5 266 0.001149 230 201 46.19 210 9.701 -210 -9.701
6 213 0.001516 276 201 55.50 210 11.66 -105 -5.828
7 160 0.001884 276 201 55.50 210 11.66 0.000 0.000
8 107 0.002251 276 201 55.50 210 11.66 105 5.828
9 54.69 0.002619 276 201 55.50 210 11.66 210 11.66
10 145 0.001987 276 201 55.50 105 5.828 210 11.66
11 236 0.001355 271 201 54.49 0.000 0.000 210 11.44
12 327 0.000723 145 201 29.07 -105 -3.052 210 6.104
13 418 0.000091 18.12 201 3.644 -210 -0.765 210 0.765
14 471 -0.000277 -55.41 201 -11.14 -210 2.340 105 -1.170
15 523 -0.000645 -129 201 -25.93 -210 5.445 0.000 0.000
16 576 -0.001012 -202 201 -40.72 -210 8.551 -105 4.275

∑Fs = 264kN
∑Mnx = 91.66kN·m
∑Mny = 49.62kN·m
(3) Calculate nominal capacity for neutral axis
Pb = Cc + Ps = 2,746kN
Mnx = Mnx.conc + Mnx.bar = 336kN·m
Mny = Mny.conc + Mny.bar = 158kN·m
Mn = ( Mnx )2 + ( Mny )2 = 371kN·m

14. Check Moment Capacity ( Neutral axis )


2022-08-16 19:36 3
Proposed Petro Gazz Apopong
Apopong, General Santos City

MEMBER NAME : PEDESTAL

Calculation Summary ( Check Moment Capacity ( Neutral axis ) )


Category Value Criteria Ratio Note
Moment Capacity ( Dir. X ) ( kN·m ) 53.49 223 0.240 Mux / øMnx
Moment Capacity ( Dir. Y ) ( kN·m ) 31.11 135 0.231 Muy / øMny
Axial Capacity ( kN ) 140 588 0.237 Pu / øPn
Moment Capacity ( kN·m ) 61.88 261 0.237 Mu / øMn

Moment Capacity ( Dir. X ) 0.24

Moment Capacity ( Dir. Y ) 0.23

Axial Capacity 0.24

Moment Capacity 0.24

0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20 1.30 1.40 1.50
(1) Calculate capacity of compression stress block
c = 251mm, a = β1 ㆍ c = 214mm
Acom = 52,462mm²
ccx = 108mm, ccy = 168mm
Cc = 0.85 ㆍ fck ㆍ Acom = 936kN
Mnx = Cc ㆍ ccy = 157kN·m
Mny = Cc ㆍ ccx = 102kN·m
(2) Calculate capacity of rebar
ds fs As Fs dy Mnx dx Mny
i εs
(mm) (MPa) (mm²) (kN) (mm) (kN) (mm) (kN)
1 629 -0.004510 -276 201 -55.50 -210 11.66 -210 11.66
2 538 -0.003426 -276 201 -55.50 -105 5.828 -210 11.66
3 447 -0.002342 -276 201 -55.50 0.000 0.000 -210 11.66
4 357 -0.001258 -252 201 -50.62 105 -5.315 -210 10.63
5 266 -0.000175 -34.92 201 -7.022 210 -1.475 -210 1.475
6 213 0.000456 91.16 201 18.33 210 3.850 -105 -1.925
7 160 0.001086 217 201 43.69 210 9.174 0.000 0.000
8 107 0.001717 276 201 55.50 210 11.66 105 5.828
9 54.69 0.002347 276 201 55.50 210 11.66 210 11.66
10 145 0.001263 253 201 50.80 105 5.334 210 10.67
11 236 0.000179 35.84 201 7.207 0.000 0.000 210 1.514
12 327 -0.000905 -181 201 -36.39 -105 3.821 210 -7.641
13 418 -0.001989 -276 201 -55.50 -210 11.66 210 -11.66
14 471 -0.002619 -276 201 -55.50 -210 11.66 105 -5.828
15 523 -0.003249 -276 201 -55.50 -210 11.66 0.000 0.000
16 576 -0.003880 -276 201 -55.50 -210 11.66 -105 5.828

∑Fs = -252kN
∑Mnx = 103kN·m
∑Mny = 55.51kN·m
(3) Calculate nominal capacity for neutral axis
Pn = Cc + Ps = 685kN
Mnx = Mnx.conc + Mnx.bar = 260kN·m
Mny = Mny.conc + Mny.bar = 157kN·m
Mn = ( Mnx )2 + ( Mny )2 = 304kN·m
(4) Calculate strength reduction factor
εt.min = 0.0014, εt.max = 0.0050
εt = 0.004510
ø = 0.859
2022-08-16 19:36 4
Proposed Petro Gazz Apopong
Apopong, General Santos City

MEMBER NAME : PEDESTAL

(5) Calculate axial load and moment capacities


øPn = 588kN
øMnx = 223kN·m
øMny = 135kN·m
øMn = 261kN·m
Mux / øMnx = 0.240 < 1.000 → O.K
Muy / øMny = 0.231 < 1.000 → O.K
Pu / øPn = 0.237 < 1.000 → O.K
Mc / øMn = 0.237 < 1.000 → O.K

P (kN)
5500
θ=31.15˚
N.A=30.18˚
4850

4200

3550

2900
2752 eb=430.76mm
2250

1600

950
(588,261)
300
(140,62) M (kN·m)
0
-350

-1000
0
40

80

120

160

200

240

280

320

360

400

15. Check Shear Capacity


Calculation Summary ( Check Shear Capacity )
Category Value Criteria Ratio Note
Shear Strength ( Dir. X ) ( kN ) 11.30 327 0.0346 Vux / øVnx
Spacing Limits for Reinforcement ( Dir. X ) ( mm ) 100 256 0.391 sx / sx,max
Shear Strength ( Dir. Y ) ( kN ) 10.13 327 0.0310 Vux / øVnx
Spacing Limits for Reinforcement ( Dir. Y ) ( mm ) 100 256 0.391 sy / sy,max

Shear Strength ( Dir. X ) 0.03

Spacing Limits for Reinforcement ( Dir. X ) 0.39

Shear Strength ( Dir. Y ) 0.03

Spacing Limits for Reinforcement ( Dir. Y ) 0.39

0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20 1.30 1.40 1.50
(1) Calculate maximum space
ø = 0.750
Smax = min(16DMainBar , 48DStirrup , B, D) = 256mm
(2) Calculate Shear Strength (Direction X)
s = 100mm < smax = 256mm → O.K
Nu
øVc = ø0.17 (1+ ) f'c bw d = 140kN
14Ag
Av fyt d
øVs = ø = 187kN
s
2022-08-16 19:36 5
Proposed Petro Gazz Apopong
Apopong, General Santos City

MEMBER NAME : PEDESTAL

øVn = øVc + øVs = 327kN


Vu / øVn = 0.0346 → O.K
(3) Calculate Shear Strength (Direction Y)
s = 100mm < smax = 256mm → O.K
Nu
øVc = ø0.17 (1+ ) f'c bw d = 140kN
14Ag
Av fyt d
øVs = ø = 187kN
s
øVn = øVc + øVs = 327kN
Vu / øVn = 0.0310 → O.K

2022-08-16 19:36 6
Proposed Petro Gazz Apopong
Apopong, General Santos City

MEMBER NAME : FOOTING

1. General Information
(1) Design Code : ACI318M-14
(2) Code Unit : N, mm
2,000
2. Material
1,000 1,000
(1) F'c : 21.00MPa
(2) Fy : 276MPa

3. Section

1,000
(1) Section Size
Depth : 300mm

2,000
Cover : 75.00mm
(2) Column Section
Y1

1,000
Shape of Column : Rectangle
Section : 500x500mm
X1
4. Rebar
(1) Direction Y
Layer 1 : d16@246 (As = 817mm²)
(2) Direction X
Layer 1 : d16@246 (As = 817mm²)

5. Foundation
1,700

(1) Foundation Size


Lx : 2.000m
Ly : 2.000m
fe : 126kN/m²
300

6. Design Load
(1) Service Load
Ps : 34.90kN
Msx : 13.21kN·m
Msy : 23.64kN·m
(2) Factored Load
Pu : 140kN
Mux : 53.49kN·m
Muy : 31.11kN·m
(3) Surcharge Load
Surface Load : 1.900KPa
Weight Density : 18.00kN/m³
Soil Height : 1.700m
(4) Self weight is considered.

7. Check Soil Capacity


(1) Calculate actual soil stress
qs,top-left = 40.21kN/m² qs,top-right = 75.67kN/m²
qs,bot-left = 20.40kN/m² qs,bot-right = 55.86kN/m²
qs,max = 75.67kN/m²
qs,max / fe = 0.599 → O.K
(2) Calculate factored soil stress
qu,top-left = 112kN/m² qu,top-right = 159kN/m²
qu,bot-left = 31.62kN/m² qu,bot-right = 78.29kN/m²
qu,max = 159kN/m² qu,min = 31.62kN/m²

8. Check Shear
2022-08-16 19:36 1
Proposed Petro Gazz Apopong
Apopong, General Santos City

MEMBER NAME : FOOTING

(1) Calculate one-way shear


ø = 0.750
Vux = 29.33kN øVcx = 254kN
Vux / øVcx = 0.116 → O.K
Vuy = 46.09kN øVcy = 235kN
Vuy / øVcy = 0.196 → O.K
(2) Calculate two-way shear
b0 Vc1 Vc2 Vc3 Vc Vu øVc
- Ratio
(mm) (kN) (kN) (kN) (kN) (kN) (kN)
Interior 2,868 1,455 1,190 941 941 122 706 0.172
Edge(X) 3,434 1,742 1,104 1,127 1,104 77.92 828 0.0941
Edge(Y) 3,434 1,742 1,104 1,127 1,104 77.92 828 0.0941
Corner 2,717 1,378 807 892 807 0.000 605 0.000

INTERIOR EDGE( X ) EDGE( Y ) CORNER

ø = 0.750
d = 217mm
2
Vc1 = 0.17 ( 1 + ) f'c b0 d
β
as d
Vc2 = 0.083 ( + 2 ) f'c b0 d
b0
Vc3 = 0.33 f'c b0 d
Vc = min(Vc1 , Vc2 , Vc3 )
Vu = 122kN
Vu / øVc = 0.172 → O.K

9. Check Moment Capacity


(1) Calculate moment capacity (Direction X)
ø = 0.900
Muy = 14.74kN·m øMny = 42.78kN·m
Muy / øMny = 0.344 → O.K
(2) Calculate moment capacity (Direction Y)
ø = 0.900
Mux = 18.28kN·m øMnx = 39.53kN·m
Mux / øMnx = 0.462 → O.K

10. Check Rebar


(1) Calculate minimum rebar area required
As,min = 0.00200D = 600mm²
(2) Calculate minimum rebar space required (Direction Y)
As = 201mm² (d16@246)
sreq. = 335mm
2022-08-16 19:36 2
Proposed Petro Gazz Apopong
Apopong, General Santos City

MEMBER NAME : FOOTING

sx = 246mm < sreq. = 335mm → O.K


(3) Calculate minimum rebar space required (Direction X)
As = 201mm² (d16@246)
sreq. = 335mm
sy = 246mm < sreq. = 335mm → O.K

2022-08-16 19:36 3
Proposed Petro Gazz Apopong
Apopong, General Santos City

MEMBER NAME : BASE PLATE

1. General Information
(1) Design Code : AISC-LRFD16M
(2) Code Unit : N, mm
500
2. Material
(1) Base Plate : A992 (Fy = 345MPa, Es = 199,948MPa) 450

(2) Rib / Wing : A36 304.8

(3) Anchor Bolt : A325


(4) Concrete : 21.00MPa
10
3. Section

312.42
(1) Column : W12X72

500
450
(2) Base Plate : 450x450x20.00t (Rectangle)
(3) Anchor Bolt : 4-3/4 (Pos.(x) : 50.00mm, Pos.(y) : 50.00mm)
(4) Wing Plate : 100x6.000t

50
(5) Rib Plate : 100x6.000t (No(x) : 3EA, No(y) : 3EA) 50
(6) Pedestal : 500x500 (Rectangle)

4. Design Forces
(1) Pu : 39.59kN
(2) Mux : 33.49kN·m

100
30
(3) Muy : 11.11kN·m
(4) Vux : 8.300kN
10
(5) Vuy : 6.130kN

5. Check bearing stress of base plate


(1) Bearing Stress
fmax = 7.498N (Area = 1.000mm²)
fmin = 0.0347N (Area = 1.000mm²)
σmax = 7.498MPa
σmin = 0.0347MPa
(2) Calculate Bearing Stress of Concrete
Φ = 0.650
A1 = 202,500mm², A2 = 250,000mm²
Fn = 0.85 fck A2 / A1 = 19.83MPa
øFn = 12.89MPa
(3) Calculate ratio
σmax / øFn = 0.582 < 1.000 → O.K

2022-08-16 19:36 1
Proposed Petro Gazz Apopong
Apopong, General Santos City

MEMBER NAME : BASE PLATE

7.50

0.94 2.06 3.19 4.31 5.44 6.56

0.00 1.50 2.62 3.75 4.87 6.00 7.50

6. Check tension stress of anchor bolt

2022-08-16 19:36 2
Proposed Petro Gazz Apopong
Apopong, General Santos City

MEMBER NAME : BASE PLATE

-0.36

-41.21 -30.93

-37.77 -30.90 -24.04 -17.17 -10.30 -3.43

-41.21 -34.34 -27.47 -20.60 -13.74 -6.87 0.00

(1) Tension Forces


Tu.max = -41.21kN
Tu.min = -0.364kN
(2) Check Tensile Strength
Φ = 0.750
Fnt = 621MPa
Ab = 285mm²
Rnt = Fnt x Ab = 177kN
øRnt = 133kN
(3) Calculate ratio
Tu.max / øRnt = 0.311 < 1.000 → O.K

7. Check base plate


(1) Moment Diagram ( Element Force. Nodal Average is not Applied. )
Moment Diagram (Mxx)

2022-08-16 19:36 3
Proposed Petro Gazz Apopong
Apopong, General Santos City

MEMBER NAME : BASE PLATE

-9.536kN·m/m

-2.79 -2.06 -1.34 -0.61 0.11 0.84

-14.40 -2.43 -1.70 -0.98 -0.25 0.47 15.10

Moment Diagram (Myy)

2022-08-16 19:36 4
Proposed Petro Gazz Apopong
Apopong, General Santos City

MEMBER NAME : BASE PLATE

-7.617kN·m/m

-2.85 -2.13 -1.40 -0.68 0.05 0.77

-11.76 -2.49 -1.76 -1.04 -0.31 0.41 14.90

(2) Shear Force Diagram


Shear Force Diagram (Vxx)

2022-08-16 19:36 5
Proposed Petro Gazz Apopong
Apopong, General Santos City

MEMBER NAME : BASE PLATE

-116.84 -71.74 -26.63 18.47 63.57 108.68

-1053.43 -94.29 -49.18 -4.08 41.02 86.13 1479.96

Shear Force Diagram (Vyy)

2022-08-16 19:36 6
Proposed Petro Gazz Apopong
Apopong, General Santos City

MEMBER NAME : BASE PLATE

-110.37 -67.62 -24.87 17.88 60.63 103.38

-1132.23 -89.00 -46.25 -3.50 39.25 82.01 1165.51

(3) Design Moment (Use Average)


Mux = -9.536kN·m/m
Muy = -7.617kN·m/m
Mu = max( Mux , Muy ) = -9.536kN·m/m
(4) Calculate moment strength
Φ = 0.900
Zbp = (tbp )2 / 4 = 100 mm3 /mm
Mn = Fy x Zbp = 34.47kN·m/m
øMn = 31.03kN·m/m
(5) Calculate ratio
Mu / øMn = 0.307 < 1.000 → O.K

8. Force Diagram ( Rib Plate / Wing Plate )


(1) Force Diagram
Moment Diagram

2022-08-16 19:36 7
Proposed Petro Gazz Apopong
Apopong, General Santos City

MEMBER NAME : BASE PLATE

-0.05 0.29 0.63 0.97 1.31 1.65

-0.22 0.12 0.46 0.80 1.14 1.48 1.82

Shear Force Diagram

2022-08-16 19:36 8
Proposed Petro Gazz Apopong
Apopong, General Santos City

MEMBER NAME : BASE PLATE

-18.17 -7.85 2.46 12.78 23.10 33.41

-23.33 -13.01 -2.69 7.62 17.94 28.26 38.57

9. Check rib plate ( Moment Strength )


(1) Design Forces
Mu = 1.817kN·m
(2) Calculate nominal flexural strength for Yielding (Y)
Mp = Fy Zx = 3.723kN·m
My = Fy Sx = 2.482kN·m
Mn1 = min(Mp , 1.6My ) = 3.723kN·m
(3) Calculate nominal flexural strength for Lateral-torsional buckling (LTB)
0.08 Es Lb d 1.9 Es
= 64.44 < 2 = 174 < = 1,531
Fy t Fy
Lb d
Mn = Cb ( 1.52 - 0.274 ( 2 ) Fy ) My = 3.626kN·m
t
Mn2 = min( Mn , Mp ) = 3.626kN·m
(4) Calculate flexural strength about major axis
Mnx = min(Mn1 , Mn2 ) = 3.626kN·m
Resistance factor for flexure : ø = 0.900
øMnx = 3.263kN·m
Mux / øMnx = 0.557 < 1.000 → O.K

10. Check rib plate ( Shear Strength )


(1) Design Forces
Vu = 38.57kN
(2) Calculate the web shear coefficient (Cv )
for webs of all other doubly/singly symmetric shapes and channels
h / tw = 0.000 < 1.10 kv Es / Fy = 69.81

2022-08-16 19:36 9
Proposed Petro Gazz Apopong
Apopong, General Santos City

MEMBER NAME : BASE PLATE

Cv = 1.000
(3) Calculate shear strength in local-y direction
Aw = 600mm²
Vny = 0.6 Fy Aw Cv2 = 89.36kN
Resistance factor for shear : ø = 0.900
øVny = 80.42kN
Vuy / øVny = 0.480 < 1.000 → O.K

11. Check wing plate ( Moment Strength )


(1) Design Forces
Mu = 0.649kN·m
(2) Calculate nominal flexural strength for Yielding (Y)
Mp = Fy Zx = 3.723kN·m
My = Fy Sx = 2.482kN·m
Mn1 = min(Mp , 1.6My ) = 3.723kN·m
(3) Calculate nominal flexural strength for Lateral-torsional buckling (LTB)
0.08 Es Lb d 1.9 Es
= 64.44 < 2 = 868 < = 1,531
Fy t Fy
Lb d
Mn = Cb ( 1.52 - 0.274 ( 2 ) Fy ) My = 3.040kN·m
t
Mn2 = min( Mn , Mp ) = 3.040kN·m
(4) Calculate flexural strength about major axis
Mnx = min(Mn1 , Mn2 ) = 3.040kN·m
Resistance factor for flexure : ø = 0.900
øMnx = 2.736kN·m
Mux / øMnx = 0.237 < 1.000 → O.K

12. Check wing plate ( Shear Strength )


(1) Design Forces
Vu = -23.33kN
(2) Calculate the web shear coefficient (Cv )
for webs of all other doubly/singly symmetric shapes and channels
h / tw = 0.000 < 1.10 kv Es / Fy = 69.81
Cv = 1.000
(3) Calculate shear strength in local-y direction
Aw = 600mm²
Vny = 0.6 Fy Aw Cv2 = 89.36kN
Resistance factor for shear : ø = 0.900
øVny = 80.42kN
Vuy / øVny = 0.290 < 1.000 → O.K

13. Check anchor bolt (Cast-In-Place)


(1) Design Force
Number of Anchor Bolt = 4EA
Tu.max = -41.21kN
Vu = 10.32kN
Vu1 = 2.580kN
(2) Check Shear Strength
Φ = 0.750
Ab = 285mm²
Fnv = 331MPa
Rnv = Fnv x Ab = 94.33kN
øRnv = 70.75kN

2022-08-16 19:36 10
Proposed Petro Gazz Apopong
Apopong, General Santos City

MEMBER NAME : BASE PLATE

Vu1 / øRnv = 0.036 < 1.000 → O.K


(3) Check Tensile Strength
Φ = 0.750
Ab = 285mm²
Fnt = 621MPa
fv = Vu1 / Ab = 9.050MPa
Fnt
Fnt ' = 1.3Fnt - fv ≤ Fnt
øFnv
Fnt ' = 621MPa
Rnt = Fnt ' x Ab = 177kN
øRnt = 133kN
Tu.max / øRnt = 0.311 < 1.000 → O.K

14. Check Development Length of Anchor Bolt


(1) Check Development Length (Hooked Bar)
Φ = 0.750
Lanc = 667mm
Tanc = ø Fanc Aanc = 133kN
Lh1 = ( Tanc / 2 ) / ( 0.70 fck danc ) = 237mm
Lh2 = 17 danc = 324mm
Lreq = Lh1 + Lh2 = 561mm
Lreq / Lanc = 0.841 < 1.000 → O.K

2022-08-16 19:36 11