DirectCommand Installation Ag Leader Technology

ISO Liquid Manure Kit


Krohne Flow Meter
Note: Indented items indicate parts included in an
assembly listed above

Part Name/Description Part Number Quantity

Liquid Manure, Pinch Valve Kit 4200139 1


GEN 2 Large Module Mounting Kit 2001370 1
Deutsch Dust Plug – 12 Pin 2002899-12N 1
Installation Instructions – Liquid Manure Kit 2006376 1
Cable - Krohne Signal Converter 4002487 1
Cable – ISOBUS Breakout – Type 1 4002597-008 1
Cable – Flow Valve – Deutsch Flying Lead 4002641 1
Liquid Rate Control Module 4002861 1
Local CAN Terminating Plug 4002870 1
Local CAN Terminating Receptacle 4002871 1
Cable – Active Termination (Imp) 4003122 1
Cable – ISOBUS Implement 4004110-12 1
Cable – Manure Flow Control, Pinch Valve – 20ft. 4004400-20 1

Part Name/Description Part Number Quantity

Liquid Manure, Hydraulic Pump Kit 4200141 1


GEN 2 Large Module Mounting Kit 2001370 1
Deutsch Dust Plug – 12 Pin 2002899-12N 1
Installation Instructions – Liquid Manure Kit 2006376 1
Cable - Krohne Signal Converter 4002487 1
Cable – ISOBUS Breakout – Type 1 4002597-008 1
Cable – Flow Valve – Weatherpack Flying Lead 4002645 1
Liquid Rate Control Module 4002861 1
Local CAN Terminating Plug 4002870 1
Local CAN Terminating Receptacle 4002871 1
Cable – Active Termination (Imp) 4003122 1
Cable – ISOBUS Implement 4004110-12 1
Cable – Manure Flow Control, Hyd. Pump – 20ft. 4004401-20 1

Part Name/Description Part Number Quantity

ISO Swath Control Kit 4200142 1


Cable – Local CAN Breakout – Type 1 4002567-008 1
Liquid Swath Control Module 4002862 1
12 Section Boom Cable 4003949-6 1

PN: 2006376 Rev. B February 2015 Page 1 of 19


Ag Leader Technology DirectCommand Installation
ISO Liquid Manure Kit
Krohne Flow Meter

Important You will save time and prevent wrong installation of components by
closely following these step-by-step instructions. If you have
Notices questions, call Ag Leader Technology at 515-232-5363 ext. 1.
Direction words (LEFT and RIGHT) are commonly used when
describing an installation procedure. Interpret direction words as if
standing behind equipment and looking forward.
Signal words (CAUTION, IMPORTANT and NOTE) are provided to
draw attention to information that is important for the safe/correct
installation and operation of this product.
 CAUTION – will alert you to situations that will impact the
physical safety of you or others.
 IMPORTANT – will alert you to the potential for damage to
the product or loss of data.
 NOTE – will provide you with additional information to
simplify a procedure or clarify a process.

 Read all instructions first to familiarize yourself with the


installation procedures.

 Keep parts list and installation instructions for use as a


reference after completing installation.

Section Item Page


Contents Common Components 3
Component and Cable Layout – Pinch Valve 4
Component and Cable Layout – Hydraulic Pump 5
Safety Notices 6
Installing Liquid Product Control System 7
Installing the Flow Control Cable and Krohne 9
Signla Converter Cable
Installing the ISO Swath Control Kit (Optional) 15
Installing the Implement Switch (Optional) 17
Setting Up the Display 19

Page 2 of 19 February 2015 PN: 2006376 Rev. B


DirectCommand Installation Ag Leader Technology
ISO Liquid Manure Kit
Krohne Flow Meter

Common This section contains illustrations of components common to all


DirectCommand installations. Their purpose is to ensure proper
Components identification and installation in the sections that follow.

ISO Liquid Module ISO Swath Module

PN: 2006376 Rev. B February 2015 Page 3 of 19


Ag Leader Technology DirectCommand Installation
ISO Liquid Manure Kit
Krohne Flow Meter

Component
and Cable
Layout –
Pinch Valve

Page 4 of 19 February 2015 PN: 2006376 Rev. B


DirectCommand Installation Ag Leader Technology
ISO Liquid Manure Kit
Krohne Flow Meter

Component
and Cable
Layout –
Hydraulic
Pump

PN: 2006376 Rev. B February 2015 Page 5 of 19


Ag Leader Technology DirectCommand Installation
ISO Liquid Manure Kit
Krohne Flow Meter

Safety CAUTION: Implement should be lowered to ground or on


mechanical safety stops before starting work. Do not work on
Notices implement supported by hydraulic system only.

CAUTION: Be sure to wear proper eye protection when using any


power tools, such as when drilling any mounting holes.

IMPORTANT: Check behind vehicle and implement panels for any


hoses, wiring, controls, etc. that could be damaged when drilling
any mounting holes.

IMPORTANT: Disconnect Ag Leader Display, DirectCommand


components and flow meter from electrical system when welding on
equipment or jump starting unit to prevent component damage due
to power surges or excessive current

IMPORTANT: If using a non Ag Leader GPS receiver, make sure


to install the Null Modem Cable included in the Display kit, to
prevent damage to the Display or the GPS receiver.

IMPORTANT: Use the Dielectric grease to coat the seals and


terminals of each connector that will be exposed to weather or
chemicals as you plug them in.

NOTE: Be sure to follow the alignment keys on the plugs and the
receptacles carefully. Do not use excessive force when mating
connectors.

IMPORTANT: Do not drill holes in tool bar mainframe. Due to high


stress loads on toolbar, cracking may occur from drilled holes.

Page 6 of 19 February 2015 PN: 2006376 Rev. B


DirectCommand Installation Ag Leader Technology
ISO Liquid Manure Kit
Krohne Flow Meter

Installing the Parts required for procedure:


From DirectCommand Kit:
Liquid  (1) Large Module Mounting Kit PN: 2001370
Product  (1) ISOBUS Breakout Cable PN: 4002597-008
Control  (1) Liquid Rate Control Module PN: 4002861
System  (1) Local CAN Terminating Plug PN: 4002870
 (1) Local CAN Terminating Rec. PN: 4002871
 (1) ISOBUS Active Term. Cable PN: 4003122
 (1) ISOBUS Implement Cable PN: 4004110-12
Step-by-Step for 1. Determine a mounting location for the Liquid Rate Control Module
Installing the PN: 4002861. Make sure to choose a mounting location that is big
Liquid Product enough for Liquid Swath Control Module PN: 4002862 if it is
Control System needed. Mount modules where they will be protected from impact
and other hazards.

2. Use the 5 inch carriage bolts and 5/16 hardware from the Large
Module Mounting Kit PN: 2001370 to mount the modules to the
Module Mounting Plate.

3. Use the 7 inch carriage bolts, 5/16 hardware, and Large Module
Bracket Strap from the Large Module Mounting Kit to mount the
Module Mounting Plate to the machine.

Rate and Swath Control Modules Mounted to Plate

4. The cables leading from the Liquid Product Control Module to the
Liquid Manure control valve are three feet in length, so mount
Liquid Product Control Module where cables will reach.

PN: 2006376 Rev. B February 2015 Page 7 of 19


Ag Leader Technology DirectCommand Installation
ISO Liquid Manure Kit
Krohne Flow Meter
5. Plug the 24-pin FCI connector of the ISOBUS Breakout Cable,
PN: 4002597-008 to the mating connector of the Liquid Rate
Control Module.

6. Connect the 6-pin Metripack plug of the ISOBUS Implement


Cable PN: 4004110-12 to the 6-pin Metripack receptacle of the
ISOBUS Breakout Cable.

7. Connect the 6-pin Metripack plug of the ISOBUS Breakout Cable


to the 6-pin Metripack receptacle of the Active Terminator Cable
(Imp), PN: 4003122.

8. Connect the Local CAN Terminating Receptacle, PN: 4002871


and the Local CAN Terminating Plug, PN: 4002870 to the mating
connectors of the ISOBUS Breakout Cable.

ISOBUS
Breakout Cable
ISOBUS
Implement Cable

Local CAN
Terminating Rec.

Active Terminator
Cable
Local CAN
Terminating Plug

Liquid Rate Control Module with ISOBUS Cabling

9. Route the round metal connector end of the ISOBUS Implement


Cable towards the tractor.

10. Route cable to avoid any sharp edges and pinch points. Bundle up
all excess cable and tie with zip-ties.

Page 8 of 19 February 2015 PN: 2006376 Rev. B


DirectCommand Installation Ag Leader Technology
ISO Liquid Manure Kit
Krohne Flow Meter

Installing the Parts required for procedure:


From DirectCommand Kit:
Flow Control  (1) Dust Plug – 12 pin PN: 2002899-12N
Cable and  (1) Krohne Signal Converter Cable PN: 4003970-6
Krohne AND
Signal  (2) Deutsch Flying Lead Cable PN: 4002641
 (1) Pinch Valve Flow Control Cable PN: 4004400-20
Converter OR
Cable  (2) Weatherpack Flying Lead Cable PN: 4002645
 (1) Hyd. Pump Flow Control Cable PN: 4004401-20

Step-by-Step 1. Connect the gray 24-pin FCI plug of the Manure Flow Control
instructions for Cable PN: 4004400-20 OR 4004401-20 to the Liquid Rate Control
installing the Module.
Flow Control
Cable and Note: Steps 2 through 10 are instructions for installing the
Krohne Signal Manure Flow Control Cable on a manure tank with a pinch
Converter Cable valve. If your manure tank is controlled with a hydraulic pump
continue to step 11.

Note: Steps 2 through 4 are instructions for installing the


Pinch Valve Flow Control Cable on a selector valve with
integrated Deutsch 2-pin receptacles. If your selector valve
has wire leads or incompatible receptacles on the solenoid
assembly proceed to step 5.

2. Locate the two Deutsch 2-pin plugs connected to the dual solenoid
on the selector valve. Disconnect these two plugs.

Selector Valve Dual Solenoid With Deutsch Receptacles

PN: 2006376 Rev. B February 2015 Page 9 of 19


Ag Leader Technology DirectCommand Installation
ISO Liquid Manure Kit
Krohne Flow Meter
3. Connect the black 2-pin Deutsch plug with the green and black
wires from the Pinch Valve Flow Control Cable, PN: 4004400-20
to the left 2-pin Deutsch receptacle on the dual solenoid below the
selector valve block.

4. Connect the black 2-pin Deutsch plug with the yellow and black
wires from the Pinch Valve Flow Control Cable to the right 2-pin
Deutsch receptacle on the dual solenoid below the selector valve
control block.

Note: Steps 5 through 10 are instructions for installing the


Pinch Valve Flow Control Cable on a selector valve with wire
leads or incompatible receptacles on the solenoid assembly.

5. Locate the two Deutsch Flying lead Cables, PN: 4002641 in the
DirectCommand Kit.

6. Locate and identify the leads coming out of the dual solenoid on the
selector valve.

Selector Valve Dual Solenoid With Wire Leads

7. Cut off the incompatible connectors on the selector valve, if


applicable. Determine how much wire length you need coming out
of the solenoids and strip back the appropriate amount of
insulation from the wires to insert into the butt connectors.

8. Insert the bare solenoid wires from the previous step into the butt
connectors on the Deutsch Flying lead Cable, PN: 4002641. The
solenoid ground wire connects to the black flying lead and the
solenoid signal wire connects to the white flying lead. Refer to
your specific selector valve literature for wiring connections.

Page 10 of 19 February 2015 PN: 2006376 Rev. B


DirectCommand Installation Ag Leader Technology
ISO Liquid Manure Kit
Krohne Flow Meter
9. Connect the 2-pin Deutsch plug with the green and black wires
from the Pinch Valve Flow Control Cable, PN: 4004400-20 to the
mating 2-pin receptacle on the Deutsch Flying lead Cable. This
should be connected to the valve increase solenoid.

10. Connect the 2-pin Deutsch plug with the yellow and black wires
from the Pinch Valve Flow Control Cable, PN: 4004400-20 to the
mating 2-pin receptacle on the Deutsch Flying lead Cable. This
should be connected to the valve decrease solenoid.

Note: Steps 11 through 18 are instructions for installing the


Manure Flow Control Cable on a manure tank with a hydraulic
pump. Otherwise continue to step 19 for flow meter
connection.

11. Locate the hydraulic control valve on the manure tank that
regulates slurry pump speed.

Note: In some applications there may be two control valves


connected to a single control channel depending on hydraulic
flow requirements.

Hydraulic Servo Control Valves Pictured

12. Locate the Weatherpack Flying Lead Cables PN: 4002645


included in the Liquid Manure Kit.

PN: 2006376 Rev. B February 2015 Page 11 of 19


Ag Leader Technology DirectCommand Installation
ISO Liquid Manure Kit
Krohne Flow Meter
13. Locate and identify the control wires coming out of the control
valve.

Arrow Points To Control Wires Exiting A Servo Valve

14. Cut off the incompatible 2-pin molded connector, if applicable.


Determine how much wire length you need coming out of the
control valve and strip back the appropriate amount of insulation
from the wires to insert into the butt connectors.

15. Insert and crimp the bare control wires from the previous step into
the butt connectors on the Weatherpack Flying Lead Cable PN:
4002645. The servo close/pwm ground wire from the valve
connects to the yellow flying lead. The servo open/pwm signal
wire from the valve connects to the green flying lead. Refer to your
specific control valve literature for wiring connections.

16. If using two control valves repeat steps 13-15 on the second
valve.

17. Connect the Weatherpack Flying Lead Cable to the mating 2-pin
tower on the Manure Flow Control Cable.

18. If using a second control valve connect the second Weatherpack


Flying Lead Cable to the other mating 2-pin tower on the Manure
Flow Control Cable.

Note: Continue to step 19 for flow meter connection.

19. Route the 3-pin Weatherpack shroud of the Manure Flow Control
Cable PN: 4004400-20 OR 4004401-20 back to the flow meter.

Page 12 of 19 February 2015 PN: 2006376 Rev. B


DirectCommand Installation Ag Leader Technology
ISO Liquid Manure Kit
Krohne Flow Meter

Typical Flow Meter Location

20. Open the signal converter on the Krohne flow meter to access the
power and signal terminal block. This procedure will vary based
on Krohne Signal Converter model.

21. Locate the Krohne Signal Converter Cable. PN: 4002487 included
in the Liquid Manure Kit.

22. Remove any existing power and signal wires connected to the
terminal block on the flow meter signal converter and install the
Krohne Signal Converter Cable.

23. Refer to the figure on the next page for power and signal
connections based on the Krohne Signal Converter installed on
your flow meter.

PN: 2006376 Rev. B February 2015 Page 13 of 19


Ag Leader Technology DirectCommand Installation
ISO Liquid Manure Kit
Krohne Flow Meter

NOTE: If you have an IFC 090 or a legacy model signal


converter a jumper wire will need to be added to connect
the additional ground. See the figure above.

Page 14 of 19 February 2015 PN: 2006376 Rev. B


DirectCommand Installation Ag Leader Technology
ISO Liquid Manure Kit
Krohne Flow Meter
24. Connect the 3-pin Weatherpack shroud from the Manure Flow
Control Cable, PN; 4004400-20 OR 4004401-20 to the 3-pin
Weatherpack tower on the Krohne Signal Converter Cable, PN:
4002487. If necessary, extension cables may be purchased for
additional length. Refer to the table below for available lengths.

Length Part Number


10 ft. 2000453-2
25 ft. 2000453-3
Optional Cable Extensions

25. Secure all cables with zip ties included in the Cable Installation Kit,
PN: 2000901-1 avoid sharp edges and pinch points that could
cause any cable damage.

26. Reinstall any covers on the signal converter removed to access


the terminal block.

Installing the Parts required for procedure:


 (1) Local CAN Breakout Cable PN: 4002567-008
ISO Swath  (1) Liquid Swath Control Module PN: 4002862
Control Kit  (1) 12 Section Boom Cable PN: 4003949-6
(Optional)

Step-by-Step for 1. Mount the Liquid Swath Control Module PN: 4002862 to the
Installing the ISO Module Mounting Plate with the Liquid Rate Control Module.
Swath Control Kit
(Optional) 2. Plug the 24-pin FCI connector of the Local CAN Breakout Cable,
PN: 4002567-008 to the mating connector of the Liquid Swath
Control Module.

3. Connect the Local CAN Terminating Receptacle, PN: 4002871 to


the mating plug of the Local CAN Breakout Cable.

4. Connect the Local CAN Terminating Plug, PN: 4002870 to the


mating receptacle of the ISOBUS Breakout Cable.

5. Connect the 6-pin Deutsch plug of the ISOBUS Breakout Cable to


the mating receptacle of the Local CAN Breakout Cable.

PN: 2006376 Rev. B February 2015 Page 15 of 19


Ag Leader Technology DirectCommand Installation
ISO Liquid Manure Kit
Krohne Flow Meter

Local CAN
Breakout Cable

ISOBUS
Breakout Cable

Local CAN
Terminating Rec.

Local CAN
Terminating Plug

Liquid Swath Control Module with Local CAN Cabling

6. Connect the gray 12-pin plug on the 12 Boom Section Cable PN:
4003949-6 to the gray 12-pin receptacle of the Liquid Swath
Control Module PN: 4002862.

7. Connect the gray 2-pin receptacle on the 12 Boom Section Cable


to one of the gray 2-pin plugs of the ISOBUS Implement Cable.

8. Connect the gray 2-pin plug of the 12 Boom Section Cable to the
mating receptacle on the Liquid Swath Control Module.

9. Connect the 3-pin Weatherpack plugs of the 12 Boom Section


Cable to the respective section valves on the implement.

10. Route all cables to avoid any sharp edges and pinch points.
Bundle up all excess cable and tie with zip-ties.

Page 16 of 19 February 2015 PN: 2006376 Rev. B


DirectCommand Installation Ag Leader Technology
ISO Liquid Manure Kit
Krohne Flow Meter

Installing an Parts required for procedure:


 (1) Implement Switch PN: 4001507
Implement
Switch  (1) Implement Switch Ext. Cable See Table B
(Optional)  (1) CAN Implement Switch Cable PN: 4002658
 (1) CAN Implement Switch Module PN: 4002911

Table B
Implement Switch Extensions Part Number
18 in. Cable 2000453-1
42 in. Cable 2000453-4
10 ft. Cable 2000453-2
25 ft. Cable 2000453-3

NOTE: If using this kit on an implement that is raised out of the ground
when not applying, it is recommended to install an optional Implement
Switch. This will prevent the controller from turning on product flow
when the implement is out of the ground and over an unapplied area of
the field.

Step-by-Step 1. Decide on a location for mounting the Implement Switch.


instructions for
installing an 2. The mounting orientation of the implement Switch Assembly
Implement determines whether the lever is off center or centered when the
Switch (Optional) implement is in the “application” position.

PN: 2006376 Rev. B February 2015 Page 17 of 19


Ag Leader Technology DirectCommand Installation
ISO Liquid Manure Kit
Krohne Flow Meter
3. For an off center orientation plug the 3-pin Weatherpack Shroud
labeled NORMALLY OPEN on the Implement Switch into the 3-pin
Weatherpack Tower of the Implement Switch Extension Cable, PN:
2000453-X. Begin routing the Extension Cable towards the CAN
Implement Switch Module avoiding pinch points, sharp edges and
allowing extra slack.

4. For a centered orientation plug the 3-pin Weatherpack Shroud


labeled NORMALLY CLOSED on the Implement Switch into the 3-
pin Weatherpack Tower of the Implement Switch Extension Cable,
PN: 2000453-X. Begin routing the Extension Cable towards the
CAN Implement Switch Module avoiding pinch points, sharp edges
and allowing extra slack.

5. Plug the 3-pin shroud of the implement switch into the 3-pin
Weatherpack tower of the CAN Implement Switch Cable PN:
4002658.

6. The CAN Implement Switch Module PN: 4002911 must be


installed on the Local CAN Bus by Teeing into the 6-pin Deutsch
bus.

Page 18 of 19 February 2015 PN: 2006376 Rev. B


DirectCommand Installation Ag Leader Technology
ISO Liquid Manure Kit
Krohne Flow Meter

Setting Up 1. Refer to the Quick Reference Guide, PN: 2006010-ENG, for further
instructions on setting up the Display.
the Display
2. Refer to the chart below for setting up the Display.

Liquid Manure Tank With Pinch Valve Servo Control and


Liquid Manure Tank With Hydraulic Pump Servo Control Valve Configuration

Setting Default Description


Name Value
Determines the speed of the servo valve when product control error exceeds the
Response Threshold setting. Decreasing the value will cause the servo valve to run
Valve 40 % slower.
response 1
Determines the speed of the servo valve when product control error is less than
the Response Threshold setting. Decreasing the value will cause the servo valve to
Valve 6% run slower.
response 2
Determines the percent of error that is allowed prior to the product control
system making any flow rate corrections. Too low of a setting will cause the
Allowable control system to continually hunt for the target application rate. Too high of a
5 - 8% setting will cause excessive application error.
Error

Determines where the control system switches between using Valve response 1
and Valve response 2 speed settings. Decreasing this value will have the overall
effect of speeding up servo valve response. Increasing this value will have the
Response overall effect of slowing down servo valve response.
20
Threshold
NOTE: Leaving all other valve control settings at the default value and making a
small adjustment to this setting is usually all that is required to fine-tune the
control system.
*See This is the number of pulses per 1 gallon of product flow thru the Flow meter.
Flow Meter
Flow
Cal*
Meter

Liquid Manure Tank Hydraulic Pump


PWM Control Valve Configuration

PULSE WIDTH MODULATION (PWM) VALVE CONTROL SETTINGS


Flow Control
Control Valve PWM
Valve Config. Frequency PWM Gain Zero Flow Offset
Contact Ag Leader for the appropriate settings and calibration of PWM valve
controlled Liquid Manure Applicators.

PN: 2006376 Rev. B February 2015 Page 19 of 19