You are on page 1of 1

APPENDIX F Garmin GI 275 as Standby Flight Display

F.1 Purpose
The Garmin GI 275 display instrument, installed by STC SA02658SE, may be installed with a
G3X PFD on certified aircraft to provide standby Attitude, Altimeter, and Airspeed Indicator
functions (except in G3X installations which include Copilot displays).
This section of the G3X installation manual describes requirements unique to this configuration.
Reference Garmin GI 275 Part 23 AML STC Installation Manual (190-02246-10) for information
beyond the scope of this document. To use the GI 275 as a standby flight display, perform the
following:
• The GI 275 backup battery pack must be retained and installed.
• The GI 275 must be configured as a Primary ADI (as defined in the GI 275 Part 23
AML STC Installation Manual) with display of attitude, altitude, and airspeed.
• The GI 275 STC requires that the GI 275 be installed in the primary field-of-view of
the pilot (±15° from centerline). The G3X STC approves moving the GI 275 to an
appropriate standby location which is described in this appendix.
• When the GI 275 is installed as a standby flight display, the G3X STC allows the
existing analog airspeed indicator, altimeter, vertical speed indicator, attitude gyro,
DG/HSI and rate-of-turn indicator to be removed as these functions are replaced by
the G3X Touch EFIS in normal operations with GI 275 as a standby.
GI 275 models approved for use as a G3X standby instrument are shown below in Table F-1.

Table F-1 – GI 275 Standby Equipment


Model Nomenclature Unit P/N Catalog P/N
GI 275 ADAHRS, Class I & II Multi-Function Instrument 011-04489-10 010-01912-10
GI 275 ADAHRS+AP, Class I Multi-Function Instrument 011-04489-20 010-01912-20
& II
Reference the GI 275 Part 23 AML STC Installation Manual for connector kits and other
hardware required to complete a GI 275 installation.
F.2 GI 275 Interfaces
The GI 275 has no interface to the G3X system. The following paragraphs provide more detail
about interface limitations and requirements for the GI 275 installed as a G3X standby
instrument.

F.2.1 Magnetometer and OAT Probe


The G3X system and GI 275 standby instrument cannot share the same GMU 11
magnetometer and GTP 59 OAT probe. If magnetic heading, OAT, TAS, and standard rate turn
bank angle pointers are desired to be displayed on the GI 275, an additional magnetometer and
OAT probe must be installed for the GI 275. Reference the GI 275 Part 23 AML STC
Installation Manual for details.

F.2.2 External Navigators


When used as a standby instrument for G3X, external navigators may not be interfaced to the
GI 275.

Installation Manual 190-02472-01


G3X Touch EFIS Part 23 AML STC Page F-1 Revision 11

You might also like