Settings of control unit for HFO separator "C7 - 623" Settings of control unit for HFO separator "D
tor "D 10"
T 00 Partial ejection 2 T 00 Partial ejection 2 T 01 Displacement 0 T 01 Displacement 0 T 01(01) Displacement-UNITROL with WMS 8 T 01(01) Displacement-UNITROL with WMS 8 T01(02) Displacement-VARIZONE 8 T01(02) Displacement-VARIZONE 8 T 01(36) Displacement-UNITROL with SMS 8 T 01(36) Displacement-UNITROL with SMS 8 T 01(96) Displacement-UNITROL-LO with SMS 8 T 01(96) Displacement-UNITROL-LO with SMS 8 01/36 8 01/36 8 01/96 8 01/96 8 T 02 Filling 0 T 02 Filling 0 T 02(01) Filling-UNITROL with WMS 8 T 02(01) Filling-UNITROL with WMS 8 T 02(02) Filling-VARIZONE 8 T 02(02) Filling-VARIZONE 8 T 02(36) Filling-UNITROL with SMS 0 T 02(36) Filling-UNITROL with SMS 0 T 02(96) Filling-UNITROL-LO with SMS 4 T 02(96) Filling-UNITROL-LO with SMS 4 01/36 0 01/36 0 01/96 8 01/96 8 T 03 Waiting after start 10 T 03 Waiting after start 10 T 04 Total ejection 2.5 T 04 Total ejection 2.5 T 05 Speed recovery after total ejection 25 T 05 Speed recovery after total ejection 25 T 06 Closing water pulse 0.08 T 06 Closing water pulse 0.08 T 07 Alarm delay 20 T 07 Alarm delay 20 T 08 Waiting after displacement 10 T 08 Waiting after displacement 10 T 09 Waiting after filling 10 T 09 Waiting after filling 10 T 10 Separator acceleration (Start) 240 T 10 Separator Start-Up 240 T 11 Bridging alarm after ejection 30 T 11 Bridging alarm after ejection 30 T 12 Waiting after first ejection 10 T 12 Waiting after first ejection 10 T 13 Speed recovery after partial ejection 10 T 13 Speed recovery after partial ejection 10 T 14 Pause closing water pulse 600 T 14 Pause closing water pulse/Break impulse 600 T 15 Circulation valve closed 60 T 15 Circulation valve closed 60 T 16 Circulation valve open 15 T 16 Circulation valve open 15 T 17 System check ( test WMS/SMS) 1 T 17 Free 1 T 18 LSHH sludge tank 10 T 18 LSHH sludge tank 10 T 19 Wa. Imp. by start 3 T 19 Wa. Imp. by start 3 T 20 Separation 3600 T 20 Separation 3600 T 21 Minimum separation time with active SMS 600 T 21 Minimum separation time with active SMS 600 Monitoring time with active SMS High T 22 Monitoring time with active SMS High water 180 T 22 water 180 T 23 Post-run feed pump delay 900 T 23 Post-run feed pump delay 900 T 24 Post-run feed sludge delay 10 T 24 Post-run feed sludge delay 10 T 25 Vibro 1 180 T 25 Vibro 1 180 T 26 Vibro 2 Saf. Water 9 T 26 Vibro 2 Saf. Water 9 T 27 PSL delay SMS 20 T 27 PSL delay SMS 20 T 28 Ejection monitoring 3 T 28 Ejection monitoring 3 T 29 Forced ejection/Brake for separ. 300 T 29 Forced ejection 300 T 30 Brake cool water 600 T 30 Brake cool water 600 T 31 Cool water 5 T 31 Cool water 5 T 32 WMS mode 1800 T 32 WMS mode 1800 T 33 SMS mode 30 T 33 SMS mode 30 T 34 Oil pressure delay 10 T 34 WMS press. Check 10 T 35 Water seal broke 300 T 35 Water seal broke 300 T 36 Filling SMS 1 T 36 SMS press. Check 1 T 37 SMS waiting 3 T 37 SMS waiting 3 T 38 WMS sensor flush 60 T 38 WMS sensor flush 60 T 39 Separator OFF 180 T 39 Separator OFF 180 T 40 CU-sludge Pu ON 120 T 41 CU-sludge Pu Break 600 Settings of control unit for LO separator "" Settings of control unit for MGO separator "" sec. sec. T 00 Partial ejection 2.00 T 00 Partial ejection 1.50 T 01 Displacement 0.00 T 01 Displacement 0.00 T 01(01) Displacement-UNITROL with WMS 8.00 T 01(01) Displacement-UNITROL with WMS 5.00 T01(02) Displacement-VARIZONE 2.00 T01(02) Displacement-VARIZONE 5.00 T 01(36) Displacement-UNITROL with SMS 8.00 T 01(36) Displacement-UNITROL with SMS 5.00 T 01(96) Displacement-UNITROL-LO with SMS 8.00 T 01(96) Displacement-UNITROL-LO with SMS 4.00 01/36 8.00 01/36 5.00 01/96 8.00 01/96 5.00 T 02 Filling 0.00 T 02 Filling 0.00 T 02(01) Filling-UNITROL with WMS 8.00 T 02(01) Filling-UNITROL with WMS 0.00 T 02(02) Filling-VARIZONE 4.00 T 02(02) Filling-VARIZONE 5.00 T 02(36) Filling-UNITROL with SMS 0.00 T 02(36) Filling-UNITROL with SMS 0.00 T 02(96) Filling-UNITROL-LO with SMS 4.00 T 02(96) Filling-UNITROL-LO with SMS 1.00 01/36 0.00 01/36 0.00 01/96 8.00 01/96 5.00 T 03 Waiting after start 10.00 T 03 Waiting after start 10.00 T 04 Total ejection 2.00 T 04 Total ejection 2.00 T 05 Speed recovery after total ejection 25.00 T 05 Speed recovery after total ejection 25.00 T 06 Closing water pulse 0.18 T 06 Closing water pulse 0.08 T 07 Alarm delay 20.00 T 07 Alarm delay 20.00 T 08 Waiting after displacement 10.00 T 08 Waiting after displacement 10.00 T 09 Waiting after filling 10.00 T 09 Waiting after filling 10.00 T 10 Separator acceleration (Start) 240.00 T 10 Separator Start-Up 240.00 T 11 Bridging alarm after ejection 30.00 T 11 Bridging alarm after ejection 30.00 T 12 Waiting after first ejection 10.00 T 12 Waiting after first ejection 10.00 T 13 Speed recovery after partial ejection 10.00 T 13 Speed recovery after partial ejection 10.00 T 14 Pause closing water pulse 600.00 T 14 Pause closing water pulse/Break impulse 600.00 T 15 Circulation valve closed 60.00 T 15 Circulation valve closed 600.00 T 16 Circulation valve open 15.00 T 16 Circulation valve open 15.00 T 17 System check ( test WMS/SMS) 1.00 T 17 Free 1.00 T 18 LSHH sludge tank 10.00 T 18 LSHH sludge tank 10.00 T 19 Wa. Imp. by start 3.00 T 19 Wa. Imp. by start 3.00 T 20 Separation 3600.00 T 20 Separation 7200.00 T 21 Minimum separation time with active SMS 600.00 T 21 Minimum separation time with active SMS 600.00 Monitoring time with active SMS High Monitoring time with active SMS High T 22 water 180.00 T 22 water 180.00 T 23 Post-run feed pump delay 900.00 T 23 Post-run feed pump delay 900.00 T 24 Post-run feed sludge delay 10.00 T 24 Post-run feed sludge delay 10.00 T 25 Vibro 1 180.00 T 25 Vibro 1 180.00 T 26 Vibro 2 Saf. Water 9.00 T 26 Vibro 2 Saf. Water 2.00 T 27 PSL delay SMS 20.00 T 27 PSL delay SMS 20.00 T 28 Ejection monitoring 3.00 T 28 Ejection monitoring 3.00 T 29 Forced ejection/Brake for separ. 300.00 T 29 Forced ejection 300.00 T 30 Brake cool water 600.00 T 30 Brake cool water 600.00 T 31 Cool water 5.00 T 31 Cool water 5.00 T 32 WMS mode 1800.00 T 32 WMS mode 1800.00 T 33 SMS mode 30.00 T 33 SMS mode 30.00 T 34 Oil pressure delay 10.00 T 34 WMS press. Check 10.00 T 35 Water seal broke 300.00 T 35 Water seal broke 300.00 T 36 Filling SMS 1.00 T 36 SMS press. Check 1.00 T 37 SMS waiting 3.00 T 37 SMS waiting 1.00 T 38 WMS sensor flush 60.00 T 38 WMS sensor flush 60.00 T 39 Separator OFF 1800.00 T 39 Separator OFF 1800.00 T 40 T 41